Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 294
Filtrar
Mais filtros

Eixos temáticos
Tipo de documento
Intervalo de ano de publicação
1.
J Pediatr ; 271: 114059, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38636783

RESUMO

OBJECTIVE: To assess concordance between umbilical cord blood (UCB) and neonatal blood (NB) laboratory test results at birth. STUDY DESIGN: This retrospective study considered very preterm neonates (<32 weeks' gestational age) admitted to a tertiary neonatal intensive care unit from 2012 to 2023. Inclusion criteria required neonates with a complete blood count measured in both UCB and NB drawn within 2 hours after birth. Median hemoglobin (Hb) and hematocrit (Hct) concentrations were compared between UCB (venous samples) and NB (venous, arterial, or capillary samples). RESULTS: A total of 432 neonates with paired UCB and NB values were included in the study. Hb concentration in UCB was 14.7 g/dL (IQR 13.5-16.1 g/dL) compared with 14.8 g/dL (IQR 12.6-19.3 g/dL) in venous NB samples, 13.9 g/dL (IQR 12.9-15.3 g/dL) in arterial NB and 18.7 g/dL (IQR 16.6-20.8 g/dL) in capillary NB. The regression equation showed a correction factor of 1.08 for converting Hb values from UCB to venous NB. Median Hct concentration in UCB was 0.45 L/L (IQR: 0.41-0.49 L/L) compared with 0.48 L/L (IQR 0.43-0.54 L/L) in venous NB, 0.42 L/L (IQR 0.38-0.45 L/L) in arterial NB and 0.57 L/L, (IQR 0.51-0.63 L/L) in capillary NB. CONCLUSIONS: Hb and Hct concentrations measured in UCB are similar to those measured in venous blood in very preterm infants and are valid alternatives for NB tests at birth. Hb and Hct concentrations in arterial and capillary NB are respectively lower and higher compared with UCB measurements.


Assuntos
Sangue Fetal , Humanos , Recém-Nascido , Sangue Fetal/química , Estudos Retrospectivos , Feminino , Masculino , Contagem de Células Sanguíneas/métodos , Hematócrito , Hemoglobinas/análise , Unidades de Terapia Intensiva Neonatal , Recém-Nascido Prematuro/sangue
2.
Am J Obstet Gynecol ; 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38527603

RESUMO

BACKGROUND: Cytomegalovirus is responsible for the most common congenital infection, affecting 0.5% to 1.0% of live births in Europe. Congenital cytomegalovirus infection can be diagnosed during pregnancy by viral DNA amplification in the amniotic fluid, but the prognosis of fetuses without severe brain abnormalities remains difficult to establish on the basis of prenatal imaging alone. OBJECTIVE: To identify predictors of moderate to severe symptomatic cytomegalovirus infection among fetal blood parameters and to propose an algorithm on the basis of these parameters and on prenatal imaging that would provide the best positive and negative predictive values. STUDY DESIGN: Fetal blood sampling at 21-28 weeks gestation was performed in fetuses with congenital cytomegalovirus infection confirmed by amniocentesis after maternal infection in the first-trimester or periconceptional period. We compared the levels of hemoglobin, thrombocytes, γ-glutamyl transpeptidase, aspartate aminotransferase, alanine aminotransferase, ß2-microglobulin, immunoglobulins G and M, and cytomegalovirus DNA viral loads in amniotic fluid and fetal blood between those with moderate to severe symptomatic infection and those with asymptomatic to mild infection (median follow-up of 36 months for live births). RESULTS: Among 58 fetuses included, 25 (43%) had a moderate to severe symptomatic infection: 16 with severe cerebral abnormalities, 5 with multiple signs or symptoms at birth, 2 with bilateral sensorineural hearing loss, and 2 with neurodevelopmental delay. The values of thrombocytes, aspartate aminotransferase, ß2 microglobulin, Immunoglobulin M, and cytomegalovirus viral loads differed significantly between fetuses with moderate to severe symptomatic infection and those with asymptomatic to mild infection. The optimal strategy to predict moderate to severe symptomatic infection was to first perform fetal brain imaging, followed by fetal blood sampling with the following cutoffs: thrombocytes <120,000/mL, viremia ≥5 log10/mL, and ß2 microglobulin ≥12 mg/L). This recursive algorithm had a negative predictive value of 100% for moderately to severely symptomatic infection. CONCLUSION: The combination of thrombocytes, ß2-microglobulin, and cytomegalovirus viral load in fetal blood can be used for prognosis determination, particularly in cytomegalovirus-infected fetuses without severe brain abnormalities at the time of prenatal diagnosis. Future studies should evaluate whether these parameters remain useful in infected fetuses who have been treated with valacyclovir before fetal blood sampling.

3.
Clin Chem Lab Med ; 62(8): 1538-1547, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-38581294

RESUMO

AIM: Blood Sampling Guidelines have been developed to target European emergency medicine-related professionals involved in the blood sampling process (e.g. physicians, nurses, phlebotomists working in the ED), as well as laboratory physicians and other related professionals. The guidelines population focus on adult patients. The development of these blood sampling guidelines for the ED setting is based on the collaboration of three European scientific societies that have a role to play in the preanalytical phase process: EuSEN, EFLM, and EUSEM. The elaboration of the questions was done using the PICO procedure, literature search and appraisal was based on the GRADE methodology. The final recommendations were reviewed by an international multidisciplinary external review group. RESULTS: The document includes the elaborated recommendations for the selected sixteen questions. Three in pre-sampling, eight regarding sampling, three post-sampling, and two focus on quality assurance. In general, the quality of the evidence is very low, and the strength of the recommendation in all the questions has been rated as weak. The working group in four questions elaborate the recommendations, based mainly on group experience, rating as good practice. CONCLUSIONS: The multidisciplinary working group was considered one of the major contributors to this guideline. The lack of quality information highlights the need for research in this area of the patient care process. The peculiarities of the emergency medical areas need specific considerations to minimise the possibility of errors in the preanalytical phase.


Assuntos
Coleta de Amostras Sanguíneas , Serviço Hospitalar de Emergência , Humanos , Coleta de Amostras Sanguíneas/normas , Coleta de Amostras Sanguíneas/métodos , Medicina de Emergência/normas , Fase Pré-Analítica/normas , Europa (Continente) , Sociedades Médicas , Química Clínica/normas , Química Clínica/métodos
4.
Colorectal Dis ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38949106

RESUMO

AIM: Follow-up for colorectal cancer (CRC) necessitates regular monitoring of carcinoembryonic antigen (CEA) at the hospital. Capillary home-based blood collection, including minimally invasive techniques such as lancet sampling or an automated upper arm device (TAP-II), has the potential to replace a significant portion of hospital-based blood sampling, thereby enhancing self-reliance and quality of life. The objectives of this study were to assess the feasibility, reliability and preference for CEA blood collection. METHODS: Baseline venous and capillary (by lancet and TAP-II) blood samples were collected from 102 participants, including 20 CRC patients with elevated CEA levels, 60 CRC patients undergoing postoperative outpatient monitoring and 20 healthy volunteers. The second group performed capillary blood collections at home on two consecutive follow-up appointments and subsequently sent them to the hospital. Satisfaction was assessed via patient reported outcome measures on pain, burden, ease of use and preference. RESULTS: The Pearson's correlation test of all usable samples resulted in a linear coefficient of 0.998 (95% CI 0.997-0.998) for the TAP-II method and 0.997 (95% CI 0.996-0.998) for the lancet method, both compared to venipuncture. Following the initial blood collection, 86% of the participants (n = 102) favoured the TAP-II, rating it as the least painful and burdensome option. After two home-based blood samples, the preference for the TAP-II method persisted, with 64% of the patients endorsing its use. CONCLUSION: This study demonstrated the feasibility of home-based capillary sampling of CEA. The TAP-II blood collection is the most reliable method and is preferred by patients over venipuncture and lancet sampling.

5.
Acta Obstet Gynecol Scand ; 103(3): 479-487, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38059396

RESUMO

INTRODUCTION: Since the 1970s, fetal scalp blood sampling (FSBS) has been used as a second-line test of the acid-base status of the fetus to evaluate fetal well-being during labor. The commonly employed thresholds that delineate normal pH (>7.25), subnormal (7.20-7.25), and pathological pH (<7.20) guide clinical decisions. However, these experienced-based thresholds, based on observations and common sense, have yet to be confirmed. The aim of the study was to investigate if pH drop rate accelerates at the common thresholds (7.25 and 7.20) and to explore the possibility of identifying more accurate thresholds. MATERIAL AND METHODS: A retrospective study was conducted at a tertiary maternity hospital between June 2017 and July 2021. Patients with at least one FSBS during labor for category II fetal heart rate and delivery of a singleton cephalic infant were included. The rate of change in pH value between consecutive samples for each patient was calculated and plotted as a function of pH value. Linear regression models were used to model the evolution of the pH drop rate estimating slope and standard errors across predefined pH intervals. Exploration of alternative pH action thresholds was conducted. To explore the independence of the association between pH value and pH drop rate, multiple linear regression adjusted on age, body mass index, parity, oxytocin stimulation and suspected small for gestational age was performed. RESULTS: We included 2047 patients with at least one FSBS (total FSBS 3467); with 2047 umbilical cord blood pH, and a total of 5514 pH samples. Median pH values were 7.29 1 h before delivery, 7.26 30 min before delivery. The pH drop was slow between 7.40 and 7.30, then became more pronounced, with median rates of 0.0005 units/min at 7.25 and 0.0013 units/min at 7.20. Out of the alternative pH thresholds, 7.26 and 7.20 demonstrated the best alignment with our dataset. Multiple linear regression revealed that only pH value was significantly associated to the rate of pH change. CONCLUSIONS: Our study confirms the validity and reliability of current guideline thresholds for fetal scalp pH in category II fetal heart rate.


Assuntos
Trabalho de Parto , Couro Cabeludo , Gravidez , Humanos , Feminino , Estudos Retrospectivos , Reprodutibilidade dos Testes , Trabalho de Parto/fisiologia , Feto , Sangue Fetal , Frequência Cardíaca Fetal/fisiologia , Concentração de Íons de Hidrogênio , Monitorização Fetal
6.
Acta Paediatr ; 113(8): 1750-1756, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38730307

RESUMO

AIM: We conducted a meta-analysis comparing the invasiveness of automatic lancet devices, which can collect adequate amount of blood at shallow puncture depths, with conventional manual lance devices (lancet or needle) to statistically identify less invasive instruments for neonatal heel lance. METHODS: We searched PubMed, Cochrane Central Register of Controlled Trials (CENTRAL), CINAHL, and Ichushi databases for studies comparing the invasiveness between automatic lancet and manual lancet or needle in term and preterm neonates in neonatal intensive care unit. RESULTS: This review included 9 out of 449 searched articles, with 673 neonates. Automatic lancet had significantly lower pain scores (standardised mean difference: -2.0, 95% confidence interval: -3.3 to -0.7), heart rate (mean difference: -8.0, 95% confidence interval: -13.8 to -2.1), cry duration (mean difference: -21.5, 95% confidence interval: -32.5 to -10.4), number of punctures (mean difference: -0.6, 95% confidence interval: -1.1 to -0.2), and duration of procedures (mean difference: -37.7, 95% confidence interval: -75.2 to -0.2) than manual lancet or needle. Furthermore, peripheral oxygen saturation was significantly higher in automatic lancet than in manual lancet or needle (mean difference: 4.5, 95% confidence interval: 0.5-8.5). CONCLUSION: Automatic heel lancet devices were less invasive than manual heel lance devices (lancet or needle).


Assuntos
Calcanhar , Humanos , Recém-Nascido , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/instrumentação
7.
Artigo em Inglês | MEDLINE | ID: mdl-38918088

RESUMO

OBJECTIVES: The aims of this study were to assess the impact of the closed-loop sampling method on blood loss and the need for blood transfusion in pediatric patients following cardiac surgery. DESIGN: Retrospective observational study. SETTING: A single tertiary center. PARTICIPANTS: All pediatric patients younger than 4 years old who were admitted to the pediatric intensive care unit (PICU) after cardiac surgery were enrolled. The study included 100 pediatric patients in the conservative (postimplementation) group and 43 pediatric patients in the nonconservative group (preimplementation). INTERVENTIONS: Observational. MEASUREMENTS: The primary outcome was the volume of blood loss during the PICU follow-up period. The secondary outcomes were the requirement for blood transfusion in each group, duration of mechanical ventilation, length of intensive care unit (ICU) stay, length of hospital stay, and mortality. MAIN RESULTS: In the conservative (postimplementation) group, blood loss during the follow-up period was 0.67 (0.33-1.16) mL/kg/d, while it was 0.95 (0.50-2.30) mL/kg/d in the nonconservative (preimplementation) group, demonstrating a significant reduction in blood loss in the conservative group (p = 0.012). The groups showed no significant differences in terms of the required blood transfusion volume postoperatively during the first 24 hours, first 48 hours, or after 48 hours (p = 0.061, 0.536, 0.442, respectively). The frequency of blood transfusion was comparable between the groups during the first 24 hours, first 48 hours, or after 48 hours postoperatively (p = 0.277, 0.639, 0.075, respectively). In addition, the groups did not show significant differences in the duration of mechanical ventilation, length of ICU stay, length of hospital stay, or mortality. CONCLUSIONS: The closed-loop sampling method can be efficient in decreasing blood loss during postoperative PICU follow-up for pediatric patients after cardiac surgeries. However, its application did not reduce the frequency or the volume of blood transfusion in these patients.

8.
Anim Welf ; 33: e17, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38510423

RESUMO

In the UK and Republic of Ireland, the European badger (Meles meles) is considered the most significant wildlife reservoir of the bacterium Mycobacterium bovis, the cause of bovine tuberculosis (bTB). To expand options for bTB surveillance and disease control, the Animal and Plant Health Agency developed a bespoke physical restraint cage to facilitate collection of a small blood sample from a restrained, conscious badger in the field. A key step, prior to pursuing operational deployment of the novel restraint cage, was an assessment of the relative welfare impacts of the approach. We used an established welfare assessment model to elicit expert opinion during two workshops to compare the impacts of the restraint cage approach with the only current alternative for obtaining blood samples from badgers in the field, which involves administration of a general anaesthetic. Eleven panellists participated in the workshops, comprising experts in the fields of wildlife biology, animal welfare science, badger capture and sampling, and veterinary science. Both approaches were assessed to have negative welfare impacts, although in neither case were overall welfare scores higher than intermediate, never exceeding 5-6 out of a possible 8. Based on our assessments, the restraint cage approach is no worse for welfare compared to using general anaesthesia and possibly has a lower overall negative impact on badger welfare. Our results can be used to integrate consideration of badger welfare alongside other factors, including financial cost and efficiency, when selecting a field method for blood sampling free-living badgers.

9.
Fetal Diagn Ther ; 51(1): 76-84, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37812923

RESUMO

INTRODUCTION: Fetal anemia from hemolytic disease treated by intrauterine transfusion (IUT) can be performed by intraperitoneal, intracardiac, and intravascular transfusion (IVT). Objective of our study was to compare different transfusion techniques. METHODS: Retrospective review of IUT secondary to red cell alloimmunization was conducted at eight international centers from 2012 to 2020. Severe anemia suspected if middle cerebral artery peaks systolic velocity ≥1.5 multiples of the median. Demographic, delivery, and postnatal variables were analyzed. RESULTS: Total of 344 procedures, 325 IVT and 19 other techniques (non-IVT) included. No difference in demographics, history of stillbirth (20.5 vs. 15.8%, p = 0.7), prior pregnancy IUT (25.6 vs. 31.6%, p = 0.5) or neonatal transfusion (36.1 vs. 43.8%, p = 0.5). At first IUT, non-IVT had higher hydrops (42.1% vs. 20.4%, p = 0.03), lower starting hematocrit (13.3% [±6] vs. 17.7% [±8.2], p = 0.04), and trend toward lower gestational age (24.6 [20.1-27] vs. 26.4 [23.2-29.6] weeks, p = 0.08). No difference in birthweight, neonatal phototherapy, exchange, or simple transfusion was observed. CONCLUSION: This is one of the largest studies comparing techniques to treat fetal anemia. IVT was most performed, other techniques were more likely performed in hydrops, and lower starting hematocrit was seen. Neither technique affected outcomes. This study may suggest that physician's experience may be the strongest contributor of outcomes.


Assuntos
Anemia , Doenças Fetais , Isoimunização Rh , Gravidez , Recém-Nascido , Feminino , Humanos , Transfusão de Sangue Intrauterina/métodos , Doenças Fetais/terapia , Anemia/terapia , Estudos Retrospectivos , Edema , Sangue Fetal
10.
Nurs Crit Care ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654607

RESUMO

Anaemia is a common issue in patients who are admitted to intensive care units and worsens their condition throughout the stay due to the extraction of blood for diagnostic purposes. It is also well-known that an important amount of the carbon dioxide produced by health services is likely attributable to blood donation, testing and manufacture, storage or distribution of blood components. This must be taken into account to perform nursing interventions consistent with the idea of sustainable health care. In this regard, within patient blood management bundles, with the objective of minimizing the use of blood products, it is recommended to use blood-sparing techniques: small volume tubes (SVT) or closed-blood sampling devices (CBSD). Published studies before 2014 (excepting two more recent ones) have shown that by themselves, both techniques reduce drawn volume but do not decrease haemoglobin reduction and/or need of transfusion. Given the lack of cost-effectiveness studies, it may be easier to implement the use of CBSD as it does not require prior consensus on the discard volume or adaptations in the processing of laboratory tests, as is the case with SVT.

11.
Khirurgiia (Mosk) ; (2. Vyp. 2): 5-12, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38380459

RESUMO

OBJECTIVE: To justify the optimal method for determining indocyanine green plasma disappearance rate (PDRICG). MATERIAL AND METHODS: We analyzed PDRICG in intensive care units. Indocyanine green was administered intravenously at a dose of 0.25 mg/kg. PDRICG was analyzed simultaneously by using of three methods: 1) PDD (PiCCO2 LiMON device), 2) SBS with analysis of plasma samples on precise spectrophotometer, 3) SBS with analysis of plasma samples on simple experimental photometer. RESULTS: PDD method was used for 346 PDRICG tests in 256 patients. Of these, 14.3% of measurements were erroneous. Paired tests using PDD and SBS methods were performed in 299 cases. SBS method resulted erroneous data in 0.6% of cases. Certain correlation (r=0.79, p<0.001) was found between the reference method (SBS with spectrophotometry) and the PDD method. Bland-Altman plot for these two methods showed that proportional bias of mean difference was caused by extremely high PDRICG of the PDD method (for example, more than 30%/min). Comparison of two SBS variants (spectrophotometer and experimental photometer) revealed good correlation (r=0.91, p<0.001). CONCLUSION: SBS method for measuring PDRICG ensures accurate results under mechanical interferences in patients with impaired capillary blood flow. This eliminates the need for redo measurement. Duplication of the PDD and SBS methods is recommended when repeating the test is not possible (organ donors).


Assuntos
Corantes , Verde de Indocianina , Humanos , Verde de Indocianina/análise , Corantes/farmacologia , Densitometria/métodos , Hemodinâmica/fisiologia , Unidades de Terapia Intensiva
12.
Clin Chem Lab Med ; 61(1): 93-103, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36302372

RESUMO

OBJECTIVES: Clinical decision-making in emergency medicine is under constant pressure from demand and performance requirements, with blood tests being a fundamental part of this. However, the preanalytical process has received little attention. Therefore, this study aimed to investigate the quality of preanalytical phase processes in European emergency departments (EDs) from the perspectives of the three main providers: clinicians, nurses, and laboratory specialists. METHODS: This online survey, distributed among European EDs and laboratories, was supported by the European Society for Emergency Nursing (EUSEN), European Society for Emergency Medicine (EuSEM), and the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM). The size of the centres, the European region, the responder's profession and the country's economic condition were used as co-variables. RESULTS: We included 376 responses from all ED-related professions from 306 European centres. In 66.9% of all ED visits, at least one blood test was performed. Tests were requested mostly by nurses (44.6%) using electronic Order/Entry systems (65.4%). Only a minority (19%) reported not using laboratory quality indicators (QIs). Most responders defined the TAT starting point "when the laboratory receives the sample" (66.1%), defining the goal to be "less than 60 min" (69.9%), but only 42.4% of the centres estimated achieving this goal. CONCLUSIONS: Our survey illustrates the current situation on preanalytical blood sample processing in European EDs from the clinical and laboratory perspectives. The results emphasise the importance of the IT infrastructure and QI usage in this process and highlight some differences between European regions.


Assuntos
Química Clínica , Fase Pré-Analítica , Humanos , Laboratórios , Inquéritos e Questionários , Serviço Hospitalar de Emergência
13.
BMC Pediatr ; 23(1): 161, 2023 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-37024882

RESUMO

BACKGROUND: Today, due to the side effects of drugs, there is a greater desire to use non-pharmacological interventions to relieve pain caused by painful procedures. Using non-pharmacological interventions in combination is more effective than using them alone in relieving the pain of infants. Reducing sensory and environmental stimuli such as visual and auditory stimuli is one of the non-pharmacological methods to relieve pain. The aim of this study was to investigate the effect of using eye shield and ear muffs on pain intensity during venous blood sampling of premature infants. METHODS: In this clinical trial study, 148 premature neonates admitted to the Neonatal Intensive Care Unit of Rouhani and Children Hospitals in Babol were randomly assigned to four groups of 37. Fifteen minutes before intravenous blood sampling until 15 min later, in the first group, eye shield; in the second group, ear muffs, and in the third group, eye shield plus ear muffs were used. In the fourth group (control), blood sampling was performed routinely. NIPS pain scale and demographic questionnaire were used to collect the data. RESULTS: The results showed that during the venous blood sampling was a significant difference between the mean pain intensity of neonatal in the eye shield plus ear muffs group (3.14 ± 0.71), the ear muffs group (4.43 ± 1.21), the eye shield group (5.41 ± 1.04).) and the control group (5.94 ± 0.84) (P = 0.001). Moreover, after the venous blood sampling, there was a significant difference between the mean neonatal pain intensity in the eye shield plus ear muffs group (1.19 ± 0.39), the ear muffs group (1.43 ± 0.50), the eye shield group (1.33 ± 0.37) and the control group (1.89 ± 0.90) (P = 0.001). CONCLUSIONS: In this study, the pain severity during and after venous blood sampling in the ear muffs plus eye shield was lower than in other groups. Therefore, a combination of ear muffs and eye shield is recommended as a better pain reliever when performing venous blood sampling in premature infants.


Assuntos
Recém-Nascido Prematuro , Flebotomia , Recém-Nascido , Criança , Humanos , Medição da Dor , Flebotomia/efeitos adversos , Acetaminofen/uso terapêutico , Dor/etiologia , Dor/prevenção & controle
14.
Acta Paediatr ; 112(12): 2486-2492, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37565393

RESUMO

AIM: To determine if trial-related blood sampling increases the risk of later red blood cell (RBC) transfusion in very preterm infants, we compared the volume of clinical- and trial-related blood samples, in a specific trial and correlated to subsequent RBC transfusion. METHODS: For 193 very preterm infants, participating in the FortiColos trial (NCT03537365), trial-related blood volume drawn was in accordance with ethical considerations established by the European Commission. Medical records were reviewed to assess the number and accumulated volume (mL/kg) of blood samples (both clinical- and trial-related). Data were compared with the need of RBC transfusions during the first 28 days of life. RESULTS: Mean (SD) gestational age and birth weight was 28 ± 1 weeks and 1168 ± 301 g. In total, 11% of total blood volume was drawn for sampling (8.1 ± 5.1 mL/kg) and trial-related sampling accounted for 1.6 ± 0.6 mL/kg. Trial-related blood sampling had no impact on RBC transfusion (p = 0.9). CONCLUSION: Clinical blood sampling in very preterm infants is associated with blood loss and subsequent need for RBC transfusions. In a specific trial requiring blood samples, we found no additional burden of trial-related blood sampling. The study suggests that trial-related sampling is safe if European criteria are followed.


Assuntos
Anemia Neonatal , Eritropoetina , Doenças do Prematuro , Lactente , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Transfusão de Eritrócitos/efeitos adversos , Anemia Neonatal/terapia , Recém-Nascido de muito Baixo Peso
15.
J Pediatr Nurs ; 73: e401-e408, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37863785

RESUMO

BACKGROUND: Blood sampling, which is frequently performed on children admitted to hospital, causes them pain, anxiety and fear. OBJECTIVES: The study was carried out to determine the effects of dry heat and dry cold application before blood sampling on pain, anxiety and fear levels in school age children. METHODS: The study was conducted between June and January 2021 with a parallel-group randomized controlled experimental design. It was carried out with 117 children who applied to the Pediatric Blood Collection Polyclinic of a training and research hospital. The children were assigned to dry heat application, dry cold application and control group by simple randomization. Data were collected using the Child-Family Introductory Information Form, Wong Baker Faces Pain Rating Scale (WBFPS), Child Fear Anxiety Scale (CFAS) and Medical Procedure Fear Scale (MPFS). In the data analysis, descriptive statistics, the Kruskal-Wallis H test, the Dunn test, Yates correction and the Pearson Chi-Square test were used. A level of p < 0.05 was considered statistically significant. RESULTS: It was found that children who were treated with dry heat and dry cold before blood sampling experienced less pain. The anxiety of the children in the dry heat treatment group was lower than the control group. According to the children's MPFS Operational Fear sub-dimension median scores, procedural fear was found to be lower in the dry heat application group. PRACTICE IMPLICATIONS: Pediatric nurses can safely use dry heat and dry cold application in the management of invasive procedure-related pain, and dry heat application in the management of anxiety. TRIAL REGISTRATION: This trial is registered with the US National Institutes of Health (ClinicalTrials.gov) under the number NCT05974319.


Assuntos
Temperatura Alta , Projetos de Pesquisa , Humanos , Criança , Ansiedade/etiologia , Dor/prevenção & controle , Dor/etiologia , Medo
16.
J Emerg Nurs ; 49(5): 744-754, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37389514

RESUMO

INTRODUCTION: Hemolysis of blood samples from emergency department (ED) patients leads to delays in treatment and disposition. The aim of this study is to determine the frequency of hemolysis and variables predictive of hemolysis. METHODS: This observational cohort study was conducted among three institutions: academic tertiary care center and two suburban community EDs, with an annual census of over 270,000 ED visits. Data were obtained from the electronic health record. Adults requiring laboratory analysis with at least one peripheral intravenous catheter (PIVC) inserted within the ED were eligible. Primary outcome was hemolysis of lab samples and secondary outcomes included variables related to PIVC failure. RESULTS: Between January 8, 2021 and May 9, 2022, 141,609 patient encounters met inclusion criteria. The average age was 55.5 and 57.5% of patients were female. Hemolysis occurred in 24,359 (17.2%) samples. In a multivariate analysis, when compared to 20-gauge catheters, smaller 22-gauge catheters had an increased odds of hemolysis (OR 1.78, 95% confidence interval (CI) 1.65-1.91; P < .001), while larger 18-gauge catheters had a lower odds of hemolysis (OR 0.94; 95% CI 0.90-0.98; P = .0046). Additionally, when compared to antecubital placement, hand/wrist placement demonstrated increased odds of hemolysis (OR 2.06; 95% CI 1.97-2.15; P < .001). Finally, hemolysis was associated with a higher rate of PIVC failure (OR 1.06; 95%CI 1.00-1.13; P = 0.043). DISCUSSION: This large observational analysis demonstrates that lab hemolysis of is a frequent occurrence among ED patients. Given the added risk of hemolysis with certain placement variables, clinicians should consider catheter gauge/placement location to avoid hemolysis that may result in patient care delays and prolonged hospital stays.


Assuntos
Cateterismo Periférico , Hemólise , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Flebotomia/efeitos adversos , Cateterismo Periférico/efeitos adversos , Cateteres de Demora/efeitos adversos , Serviço Hospitalar de Emergência
17.
Nurs Crit Care ; 2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37338149

RESUMO

BACKGROUND: Blood draws for laboratory investigations are essential for patient management in neonatal intensive care units (NICU). When blood samples clot before analysis, they are rejected, which delays treatment decisions and necessitates repeated sampling. AIMS: To decrease the incidence of rejected blood samples taken for laboratory investigation as a result of clotted sample. STUDY DESIGN: This retrospective observational study used routine data on blood draws from preterm infants collected between January 2017 and June 2019 in a 112-cot NICU in Qatar. Quality improvement interventions to reduce the rate of clotted blood samples included: awareness raising and safe sampling workshops with NICU staff, involvement of the neonatal vascular access team, development of a complete blood count (CBC) sample collection pathway, review of sample collection equipment, introducing the Tenderfoot® heel lance, establishment of benchmarks and provision of dedicated blood extraction equipment. RESULTS: First attempt blood draw occurred in 10 706 cases, representing a 96.2% success rate. In 427 (3.8%) cases, the samples were clotted requiring repeat collection. The overall rate of clotted specimens decreased from 4.8% in 2017 and 2018 to 2.4% in 2019, with odds ratios of 1.42 (95% confidence interval [CI] 1.13-1.78, p = .002), 1.46 (95% CI 1.17-1.81, p < .001) and 0.49 (95% CI 0.39-0.63, p < .001), respectively. The majority (87%-95%) of blood samples were by venepuncture using an intravenous (IV) catheter or the NeoSafe™ blood sampling device. Heel prick sampling was the second (2%-9%) most common method. Clotted samples were most frequently associated with needle use, 228 of 427 (53%), and IV cannula, 162 of 427 (38%), with odds ratios of 4.14 (95% CI 3.34-5.13, p < .001) and 3.11 (95% CI 2.51-3.86, p < .001), respectively. CONCLUSIONS: Our interventions over 3 years were associated with reduced rates of sample rejection due to clotting, and this led to improved patient experience through fewer repeated samplings. RELEVANCE TO CLINICAL PRACTICE: The insights gained from this project can help to improve patient care. Interventions that reduce the rate of blood sample rejection by clinical laboratories can lead to economic savings, timelier diagnostic and treatment decisions, and contribute to an improved quality care experience for all critical care patients, irrespective of age, by reducing the need for repeated phlebotomy and the risk of related complications.

18.
Aust Crit Care ; 36(2): 201-207, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35221230

RESUMO

OBJECTIVE: The objective of this study was to audit current patient blood management practice in children throughout cardiac surgery and paediatric intensive care unit (PICU) admission. DESIGN: This was a prospective observational cohort study. SETTING: This was a single-centre study in the cardiac operating room (OR) and PICU in a major tertiary children's hospital in Australia. PATIENTS: Children undergoing corrective cardiac surgery and requiring admission to PICU for postoperative recovery were included in the study. MEASUREMENTS AND MAIN RESULTS: Fifty-six patients and 1779 blood sampling episodes were audited over a 7-month period. The median age was 9 months (interquartile range [IQR] = 1-102), with the majority (n = 30 [54%]) younger than 12 months. The median number of blood sampling episodes per patient per day was 6.6 (IQR = 5.8-8.0) in total, with a median of 5.0 (IQR = 4.0-7.5) episodes in the OR and 5.0 (IQR = 3.4-6.2) episodes per day throughout PICU admission. The most common reason for blood tests across both OR and PICU settings was arterial blood gas analysis (total median = 86%, IQR = 79-96). The overall median blood sampling volume per kg of bodyweight, patient, and day was 0.63 mL (IQR = 0.20-1.14) in total. Median blood loss for each patient was 3.5 mL/kg per patient per day (IQR = 1.7-5.6) with negligible amounts in the OR and a median of 3.6 mL/kg (IQR = 1.7-5.7) in the PICU. The median Cell Saver® transfusion volume was 9.9 mL/kg per patient per day (IQR = 4.0-19.1) in the OR. The overall median volume of other infusion products (albumin 4%, albumin 20%, packed red blood cells) received by each patient was 20.1 mL/kg (IQR = 10.7-36.4) per day. Sampling events and blood loss were positively associated with PICU stay. CONCLUSIONS: Patient blood management practices observed in this study largely conform to National Blood Authority guidelines. Further implementation projects and research are needed to accelerate implementation of known effective blood conservation strategies within paediatric critical care environments.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Estado Terminal , Criança , Humanos , Lactente , Estudos de Coortes , Estudos Prospectivos , Unidades de Terapia Intensiva Pediátrica , Transfusão de Sangue
19.
Platelets ; 33(6): 879-886, 2022 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-35294323

RESUMO

Cirrhotic patients have an increased risk of bleeding and thromboembolic events, with platelets being involved as key players in both situations. The impact of peripheral versus central blood sampling on platelet activation remains unclear. In 33 cirrhotic patients, we thus analyzed platelet function in peripheral (P) and central (C) blood samples. Platelet surface expression of P-selectin, activated glycoprotein (GP) IIb/IIIa, and leukocyte-platelet aggregate formation were measured by flow cytometry in response to different agonists: thrombin receptor-activating peptide-6, adenosine diphosphate, collagen-related peptide (CrP), epinephrine, AYPGKF, Pam3CSK4, and lipopolysaccharide. Unstimulated platelet surface expression of P-selectin (p = .850) and activated GPIIb/IIIa (p = .625) were similar in peripheral and central blood samples. Stimulation with various agonists yielded similar results of platelet surface expression of P-selectin and activated GPIIb/IIIa in peripheral and central samples, except for CrP-inducible expression of activated GPIIb/IIIa (median fluorescence intensity, MFI in P: 7.61 [0.00-24.66] vs. C: 4.12 [0.00-19.04], p < .001). The formation of leukocyte-platelet aggregate was similar in central and peripheral blood samples, both unstimulated and after stimulation with all above-mentioned agonists. In conclusion, peripheral vs. central venous blood sampling does not influence the assessment of platelet activation by flow cytometry in cirrhosis.Abbreviations: ACLD: advanced chronic liver disease; ADP: adenosine diphosphate; ALD: alcoholic liver disease; AYPGKF: PAR-4 agonist AYPGKF; CrP: collagen related protein; EPI: epinephrine; FACS: fluorescence-activated cell sorting; GP: glycoprotein; HVPG: hepatic venous pressure gradient; IQR: interquartile range; LPS: lipopolysaccharide; LSM: liver stiffness measurement; MFI: median fluorescence intensity; NAFLD: nonalcoholic fatty liver disease; PAM: lipopeptide Pam3CSK4; PAR: protease-activated receptor; PBS: phosphate-buffered saline; PH: portal hypertension; TIPS: transjugular intrahepatic portosystemic stent shunt; TLR: toll-like receptor; TRAP-6: thrombin receptor-activator peptide-6; vWF: von Willebrand factor.


Assuntos
Selectina-P , Inibidores da Agregação Plaquetária , Difosfato de Adenosina/farmacologia , Plaquetas/metabolismo , Epinefrina/farmacologia , Citometria de Fluxo , Humanos , Lipopolissacarídeos/metabolismo , Cirrose Hepática/metabolismo , Selectina-P/metabolismo , Ativação Plaquetária , Agregação Plaquetária , Inibidores da Agregação Plaquetária/farmacologia , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/metabolismo , Receptores de Trombina/metabolismo
20.
Scand J Clin Lab Invest ; 82(4): 277-282, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35767028

RESUMO

INTRODUCTION: Approximately 25% of the patients with hospital acquired anemia (HAA) develop moderate to severe HAA during hospitalization. This is related to an increased risk of prolonged stay, readmission and mortality. The primary aim was during one year to characterize a population with very frequent phlebotomies based on a university hospital in the Capital Region of Denmark and the related general practitioners. MATERIAL AND METHODS: We conducted a retrospective cohort study using administrative data on phlebotomies from 1 January 2019 to 31 December 2019 analyzed at a university hospital. RESULTS: A total of 203,811 patients had 10,083,207 requisitions and 1,373,013 tubes. One percent, 1985 patients, had an extreme of frequent phlebotomies >60 tubes and formed the basis for the study population. The study population was significantly older as compared to the excluded patients (<60 tubes) (mean 65.7 vs. 51.6 years, p < .001).The likelihood of hemoglobin decrease per 100 mL blood drawn were calculated at four levels of decreases: Hemoglobin decrease of 2 mmol/L (adjusted OR; 95%; 2.03, CI 1.79-2.31), hemoglobin decrease of 3 mmol/L (adjusted OR; 95%, 1.36, CI 1.28-1.45), hemoglobin decrease of 4 mmol/L, (adjusted OR; 95%, 1.27, CI 1.19-1.35) and hemoglobin decrease of 5 mmol/L, (adjusted OR; 95% 1.22, CI 1.13-1.31). CONCLUSIONS: Moderate to severe HAA occurred in a limited group with excessive many phlebotomies. It was a worrisome trend that the frailest patients had the highest risk of developing HAA.


Assuntos
Anemia , Anemia/diagnóstico , Anemia/epidemiologia , Dinamarca/epidemiologia , Hemoglobinas , Hospitalização , Hospitais , Humanos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa