Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Shoulder Elbow Surg ; 30(10): 2260-2269, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33711500

RESUMO

BACKGROUND: Although coracoid transfers including the modified Bristow and Latarjet procedures are widely used to treat anterior shoulder instability, the influence of the choice of procedure on the biomechanical outcomes is not well characterized. We aimed to clarify the intra-articular stress distribution following these 2 procedures using 3-dimensional finite-element analysis and to investigate the role of stress distribution in the pathophysiology of postoperative complications. METHODS: Overall, 6 male patients aged 17-47 years with unilateral anterior shoulder instability were recruited. Computed tomographic digital imaging and communications in medicine (CT-DICOM) data of the contralateral (healthy) shoulder of each patient was obtained and used for developing the 3-dimensional normal glenohumeral joint model. A 25% bony defect was created in the anterior glenoid rim where the coracoid process was transferred in the standing and lying-down positions to create the Bristow and Latarjet models, respectively. The arm position was set as 0° or 90° abduction. The Young moduli of the humerus and scapula were calculated using CT data, and set as 35.0 MPa and 113.8 GPa for the articular cartilage and inserted screw, respectively. A compressive load (50 N) was applied to the greater tuberosity toward the center of the glenoid, and a tensile load (20 N) was applied to the tip of the coracoid in the direction of conjoint tendon. Elastic analysis was used to determine the equivalent stress distribution. RESULTS: A significant reduction in mean equivalent stress was observed within the glenoid cartilage for both models (P = .031); however, a new stress concentration appeared within the grafted coracoid-facing region of the humeral-head cartilage in both models. The proximal half of the coracoid graft exhibited lower equivalent stress than the distal half in 5 of the 6 Latarjet models, whereas the proximal half showed higher equivalent stress than the distal half in all 6 Bristow models. High stress concentration was identified at the midpoint of the inserted screw in Bristow models. DISCUSSION AND CONCLUSIONS: Intra-articular stress distribution may explain the different rates of postoperative complications associated with the modified Bristow and Latarjet procedures. New stress concentration within the humeral-head cartilage might contribute to the development of glenohumeral osteoarthritis following both procedures. Stress shielding in the proximal part of the coracoid graft might contribute to osteolysis following the Latarjet procedure. Surgeons should be aware of the risk of breakage of the inserted screw following the modified Bristow procedure.


Assuntos
Instabilidade Articular , Articulação do Ombro , Fenômenos Biomecânicos , Humanos , Cabeça do Úmero , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia , Masculino , Complicações Pós-Operatórias , Escápula/diagnóstico por imagem , Escápula/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
2.
J Shoulder Elbow Surg ; 29(12): 2632-2639, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32713665

RESUMO

BACKGROUND: Although the osteolysis of the coracoid graft is frequently observed after the Latarjet procedure particularly in its proximal part, its pathomechanism is not well understood. METHODS: Three-dimensional finite element glenohumeral joint models were developed using CT-DICOM data of 10 normal shoulders. A 25% bony defect was created on the anterior glenoid rim, and the coracoid process was transferred flush with the glenoid cartilage using 2 half-threaded screws. In the hanging arm as well as in the 90° abducted positions, a compressive load (50 N) was applied to the greater tuberosity toward the center of the glenoid and a tensile force (20 N) was applied to the coracoid tip along the direction of the conjoint tendon. Next, elastic analysis was performed, and the distribution patterns of the equivalent stress as well as the maximum principal stress were compared among 4 parts (proximal/distal and medial/lateral) of the coracoid graft. RESULTS: Both the equivalent stress and the maximum principal stress were reduced in the proximal half of the coracoid graft. A high stress concentration was observed in the lateral aspect of the coracoid graft particularly in the 90° abducted position. The proximal-medial part demonstrated the lowest equivalent stress as well as the maximum principal stress for both arm positions, which were significantly lower than those in the distal 2 parts. CONCLUSION: In the Latarjet procedure, the proximal-medial part of the coracoid graft demonstrated the most evident stress shielding, which may play an important role in postoperative osteolysis.


Assuntos
Transplante Ósseo/efeitos adversos , Processo Coracoide/transplante , Instabilidade Articular , Osteólise/fisiopatologia , Luxação do Ombro/cirurgia , Articulação do Ombro , Adolescente , Adulto , Artroscopia , Fenômenos Biomecânicos , Transplante Ósseo/métodos , Simulação por Computador , Processo Coracoide/diagnóstico por imagem , Processo Coracoide/fisiopatologia , Feminino , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Osteólise/etiologia , Recidiva , Escápula/diagnóstico por imagem , Escápula/cirurgia , Luxação do Ombro/fisiopatologia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
3.
Anticancer Res ; 36(3): 1027-31, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26976994

RESUMO

The purpose of this study was to examine the usefulness of administration of denosumab (antibody against tumor necrosis factor superfamily member 11) as a preventative therapy for skeletal-related events (SREs), such as fracture or paralysis, by computed-tomography (CT)-based on the finite element method (FEM). Patients who had undergone treatment for vertebral metastases with denosumab administration from December 2013 to August 2015 at our Institution were reviewed. We investigated patient data at the time before denosumab administration and at 1, 3 and 6 months using CT. A total of six patients were eligible; four males and two females, with ages ranging from 35 to 73 years, with a mean age of 56 years. Repeated measures analysis of variance showed a significant increase (p=0.0055, F=10.67). To our knowledge, this is the first article to substantiate the effects of the SRE-preventative drug denosumab.


Assuntos
Conservadores da Densidade Óssea/administração & dosagem , Neoplasias Ósseas/tratamento farmacológico , Neoplasias Ósseas/secundário , Denosumab/administração & dosagem , Vértebras Lombares/efeitos dos fármacos , Administração Cutânea , Adulto , Idoso , Conservadores da Densidade Óssea/farmacologia , Doenças Ósseas/etiologia , Doenças Ósseas/prevenção & controle , Neoplasias Ósseas/complicações , Neoplasias Ósseas/diagnóstico por imagem , Denosumab/farmacologia , Feminino , Análise de Elementos Finitos , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
Springerplus ; 2: 331, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23961402

RESUMO

Geometry of the proximal femur is one determinant of fracture risk, and can be analyzed by a simple method using dual-energy X-ray absorptiometry (DXA). The aim of the present study was to investigate the accuracy of hip structural analysis (HSA) using clinical data in postmenopausal Japanese women. A total of 184 postmenopausal women aged 51-88 years (mean, 70.5 ± 8.7 years) who underwent artificial joint replacement surgery for osteoarthrosis of the hip or knee joint were included. Computed tomography (CT) data from preoperative assessment were utilized for analysis of proximal femoral geometry (CT-HSA) using QCTPro Software (Mindways Software Inc., Austin, TX) and compared with HSA results based on DXA (DXA-HSA). The results of femoral geometry were further compared with a CT-based finite-element method (CT/FEM). There was moderate to high correlation between DXA-HSA and CT-HSA (r=0.60-0.90, p<0.001), except for the buckling ratio in the intertrochanteric region. Moreover, the correlation of HSA with CT/FEM was similar between DXA-HSA and CT-HSA. The present results suggest that the geometry of proximal femoral cross sections can be reasonably well characterized using DXA.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa