Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 195
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 51(5): 1215-1220, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38082197

RESUMO

This study aimed to determine whether the whole-body bone Single Photon Emission Computed Tomography (SPECT) recording times of around 10 min, routinely provided by a high-sensitivity 360° cadmium and zinc telluride (CZT) camera, can be further reduced by a deep-learning noise reduction (DLNR) algorithm. METHODS: DLNR was applied on whole-body images recorded after the injection of 545 ± 33 MBq of [99mTc]Tc-HDP in 19 patients (14 with bone metastasis) and reconstructed with 100%, 90%, 80%, 70%, 60%, 50%, 40%, and 30% of the original SPECT recording times. RESULTS: Irrespective of recording time, DLNR enhanced the contrast-to-noise ratios and slightly decreased the standardized uptake values of bone lesions. Except in one markedly obese patient, the quality of DLNR processed images remained good-to-excellent down to 60% of the recording time, corresponding to around 6 min SPECT-recording. CONCLUSION: Ultra-fast SPECT recordings of 6 min can be achieved when DLNR is applied on whole-body bone 360° CZT-SPECT.


Assuntos
Cádmio , Aprendizado Profundo , Humanos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Telúrio , Zinco
2.
Artigo em Inglês | MEDLINE | ID: mdl-39259227

RESUMO

The introduction of smaller footprint, more sensitive Cadmium-Zinc-Telluride (CZT)-based detectors with improved spatial and energy resolution has enabled the design of innovative full-ring 360° CZT SPECT/CT systems (e.g., VERITON® and StarGuide™). With this transformative technology now aiming to become mainstream in clinical practice, several critical questions need to be addressed. This EANM position paper provides practical recommendations on how to use these devices for routine bone SPECT/CT studies, facilitating the transition from traditional planar whole-body imaging and conventional SPECT/CT to these novel systems. In particular, initial guidance is provided on imaging acquisition and reporting workflows, image reconstruction, and CT acquisition parameters. Given the emerging nature of this technology, the available evidence base is still limited, and the proposed adaptations in workflows and scan protocols will likely evolve before being integrated into definitive guidelines. In the meantime, this EANM position paper serves as a comprehensive guide for integrating these advanced hybrid SPECT/CT imaging systems into clinical practice and outlining areas for further study.

3.
BMC Med Imaging ; 24(1): 94, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649862

RESUMO

BACKGROUND: Large field of view CZT SPECT cameras with a ring geometry are available for some years now. Thanks to their good sensitivity and high temporal resolution, general dynamic SPECT imaging may be performed more easily, without resorting to dedicated systems. To evaluate the dynamic SPECT imaging by such cameras, we have performed an in vivo pilot study to analyze the kidney function of a pig and compare the results to standard dynamic planar imaging by a conventional gamma camera. METHODS: A 7-week-old (12 kg) female Landrace pig was injected with [99mTc]Tc-MAG3 and a 30 min dynamic SPECT acquisition of the kidneys was performed on a CZT ring camera. A fast SPECT/CT was acquired with the same camera immediately after the dynamic SPECT, without moving the pig, and used for attenuation correction and drawing regions of interest. The next day the same pig underwent a dynamic planar imaging of the kidneys by a conventional 2-head gamma camera. The dynamic SPECT acquisition was reconstructed using a MLEM algorithm with up to 20 iterations, with and without attenuation correction. Time-activity curves of the total counts of each kidney were extracted from 2D and 3D dynamic images. An adapted 2-compartment model was derived to fit the data points and extract physiological parameters. Comparison of these parameters was performed between the different reconstructions and acquisitions. RESULTS: Time-activity curves were nicely fitted with the 2-compartment model taking into account the anesthesia and bladder filling. Kidney physiological parameters were found in agreement with literature values. Good agreement of these parameters was obtained for the right kidney between dynamic SPECT and planar imaging. Regional analysis of the kidneys can be performed in the case of the dynamic SPECT imaging and provided good agreement with the whole kidney results. CONCLUSIONS: Dynamic SPECT imaging is feasible with CZT swiveling-detector ring cameras and provides results in agreement with dynamic planar imaging by conventional gamma cameras. Regional analysis of organs uptake and clearance becomes possible. Further studies are required regarding the optimization of acquisition and reconstruction parameters to improve image quality and enable absolute quantification.


Assuntos
Câmaras gama , Rim , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Zinco , Animais , Projetos Piloto , Rim/diagnóstico por imagem , Feminino , Suínos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Cádmio , Tecnécio Tc 99m Mertiatida , Algoritmos , Compostos Radiofarmacêuticos
4.
Sensors (Basel) ; 24(3)2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38339441

RESUMO

CdZnTe (CZT) is a new type of compound semiconductor that has emerged in recent years. Compared to other semiconductor materials, it possesses an ideal bandgap, high density, and high electron mobility, rendering it an excellent room-temperature composite semiconductor material for X-ray and γ-ray detectors. Due to the exceptional performance of CZT material, detectors manufactured using it exhibit high energy resolution, spatial resolution, and detection efficiency. They also have the advantage of operating at room temperature. CZT array detectors, furthermore, demonstrate outstanding spatial detection and three-dimensional imaging capabilities. Researchers worldwide have conducted extensive studies on this subject. This paper, building upon this foundation, provides a comprehensive analysis of CZT crystals and CZT array detectors and summarizes existing research to offer valuable insights for envisioning new detector methodologies.

5.
Eur J Nucl Med Mol Imaging ; 50(12): 3647-3658, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37480369

RESUMO

BACKGROUND: Aim of this study was to define the prognostic value of stress myocardial perfusion imaging by cadmium zinc telluride (CZT) single-photon emission computed tomography (SPECT) for prediction of adverse cardiovascular events in patients with known or suspected coronary artery disease (CAD). METHODS AND RESULTS: Studies published until November 2022 were identified by database search. We included studies using stress myocardial perfusion imaging by CZT-SPECT to evaluate subjects with known or suspected CAD and providing primary data of adverse cardiovascular events. Total of 12 studies were finally included recruiting 36,415 patients. Pooled hazard ratio (HR) for the occurrence of adverse events was 2.17 (95% confidence interval, CI, 1.78-2.65) and heterogeneity was 66.1% (P = 0.001). Five studies reported data on adjusted HR for the occurrence of adverse events. Pooled HR was 1.69 (95% CI, 1.44-1.98) and heterogeneity was 44.9% (P = 0.123). Seven studies reported data on unadjusted HR for the occurrence of adverse events. Pooled HR was 2.72 (95% CI, 2.00-3.70). Nine studies reported data useful to calculate separately the incidence rate of adverse events in patients with abnormal and normal myocardial perfusion. Pooled incidence rate ratio was 2.38 (95% CI, 1.39-4.06) and heterogeneity was 84.6% (P < 0.001). The funnel plot showed no evidence of asymmetry (P = 0.517). At meta-regression analysis, we found an association between HR for adverse events and presence of angina symptoms and family history of CAD. CONCLUSIONS: Stress myocardial perfusion imaging by CZT-SPECT is a valuable noninvasive prognostic indicator for adverse cardiovascular events in patients with known or suspected CAD.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Cádmio , Prognóstico , Tomografia Computadorizada de Emissão
6.
Eur J Nucl Med Mol Imaging ; 50(7): 1940-1953, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36786817

RESUMO

BACKGROUND: Despite the demonstrated adverse outcome, it is difficult to early identify the risks for patients with ischemia and no obstructive coronary artery disease (INOCA). We aimed to explore the prognostic potential of CZT SPECT in INOCA patients. METHODS: The study population consisted of a retrospective cohort of 118 INOCA patients, all of whom underwent CZT SPECT imaging and invasive coronary angiography (ICA). Dynamic data were reconstructed, and MBF was quantified using net retention model. Major adverse cardiovascular events (MACEs) were defined as cardiovascular death, nonfatal myocardial infarction, nonfatal stroke, heart failure, late coronary revascularization, or hospitalization for unstable angina. RESULTS: During a median follow-up of 15 months (interquartile range (IQR) 11-20), 19 (16.1%) MACEs occurred; both stress myocardial blood flow (sMBF) ([Formula: see text]) and coronary flow reserve (CFR) ([Formula: see text]) were significantly lower in the MACE group. Optimal thresholds of sMBF<3.16 and CFR<2.52 were extracted from the ROC curves, and both impaired sMBF (HR: 15.08; 95% CI 2.95-77.07; [Formula: see text]) and CFR (HR: 6.51; 95% CI 1.43-29.65; [Formula: see text]) were identified as prognostic factors for MACEs. Only sMBF<3.16 (HR: 11.20; 95% CI 2.04-61.41; [Formula: see text]) remained a robust predictor when sMBF and CFR were integrated considered. Compared with CFR, sMBF provides better prognostic model discrimination and reclassification ability (C-index improvement = 0.06, [Formula: see text]; net reclassification improvement (NRI) = 0.19; integrated discrimination improvement (IDI) = 0.10). CONCLUSION: The preliminary results demonstrated that quantitative analysis on CZT SPECT provides prognostic value for INOCA patients, which may allow the stratification for early prevention and intervention.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Projetos Piloto , Prognóstico , Estudos Retrospectivos , Angiografia Coronária/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Imagem de Perfusão do Miocárdio/métodos
7.
J Nucl Cardiol ; 30(6): 2644-2654, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37464251

RESUMO

INTRODUCTION: Myocardial perfusion imaging (MPI) protocols have not changed significantly despite advances in instrumentation and software. We compared an early post-injection, stress-first SPECT protocol to standard delayed imaging. METHODS: 95 patients referred for SPECT MPI were imaged upright and supine on a Spectrum Dynamics D-SPECT CZT system with CT attenuation correction. Patients received injection of 99mTc tetrofosmin at peak of regadenoson stress and were imaged. Early post-stress (mean 17 ± 2 minutes) and Standard 1-h delay (mean 61 ± 13 min). Three blinded readers evaluated images for overall interpretation, perceived need for rest imaging, image quality, and reader confidence. Laboratory efficiency was also evaluated. RESULTS: Blinded readers had the same response for the need for rest in 77.9% of studies. Studies also had the same interpretation in 89.5% of studies. Reader confidence was high (86.0% (Early) and 90.3% (Standard p = 0.52. Image quality was good or excellent in 87.4% Early vs 96.8% Standard (p = 0.09). Time between patient check-in and end of stress imaging was 104 ± (Standard) to 60 ± 18 minutes (Early) (p < 0.001). CONCLUSION: Early post-injection stress-only imaging using CZT SPECT/CT appears promising with Tc-99m tetrofosmin with similar image quality, reader confidence, diagnosis, and need for a rest scan.


Assuntos
Imagem de Perfusão do Miocárdio , Humanos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Cintilografia , Cádmio , Telúrio
8.
J Nucl Cardiol ; 30(6): 2618-2632, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37491508

RESUMO

PURPOSE: CZT SPECT with the enhanced imaging characteristic facilitates SPECT myocardial blood flow (MBF) quantitation moving toward a clinical utility to uncover myocardial ischemia. The purpose of this study was to investigate the diagnostic performance of stress MBF, myocardial flow reserve (MFR) and myocardial flow capacity (MFC) derived from CZT SPECT in the detection of coronary artery disease (CAD). METHODS: One-hundred and eighty patients underwent two-day rest/adenosine-stress scans for SPECT MBF quantitation. All dynamic SPECT images were reconstructed and corrected with necessary corrections. The one-tissue two-compartment kinetic model was utilized to fit kinetic parameters (K1, k2 and FBV) by numeric optimization and converted to MBF from K1. Rest MBF, stress MBF and MFR in left ventricle and coronary territories were calculated from flow polar maps. MFC was assessed by extents of moderately and severely abnormal flow statuses using an integrated flow diagram. Per-patient and per-vessel analyses were performed to determine cutoff values for the detection of angiographically obstructive and flow-limited CAD. RESULTS: Using the threshold of ≥ 50% stenosis, 149 patients (82.78%) were classified to have obstructive lesions in 355 vessels (65.74%). Using the threshold of ≥ 70% stenosis, 113 patients (62.78%) were classified to have flow-limited lesions in 282 vessels (52.22%). On per-patient analysis, the optimal cutoff values of stress MBF and MFR to detect ≥ 50% stenosis were (1.44 ml/min/g, 1.96) and (1.34 ml/min/g and 1.75) to detect ≥ 70% stenosis. The optimal cutoff values for severely and combined moderately severely abnormal MFC extents were (2.3-2.5%, 23.1%) and (7.5%, 29.4%), respectively. The overall sensitivity of MFC (0.84-0.86, 0.86-0.90) to detect ≥ 50% and ≥ 70% lesions surpassed those of stress MBF (0.78. 0.78) and MFR (0.80, 0.75) (all p < 0.05) with similar specificity (MFC = 0.84-0.90, 0.87-0.91; stress MBF = 0.87, 0.91; MFR = 0.84, 0.89) (all p≥ 0.05). CONCLUSION: The non-invasive SPECT MBF quantitation using CZT SPECT is a reliable method to detect angiographically obstructive and flow-limited CAD. Myocardial flow capacity can outperform with higher diagnostic sensitivity than stress MBF or MFR alone.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Imagem de Perfusão do Miocárdio , Humanos , Constrição Patológica , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Coração , Circulação Coronária , Imagem de Perfusão do Miocárdio/métodos
9.
J Nucl Cardiol ; 30(5): 1973-1982, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36929293

RESUMO

BACKGROUND: Angiography derived fractional flow reserve (angio-FFR) has been proposed. This study aimed to assess its diagnostic performance with cadmium-zinc-telluride single emission computed tomography (CZT-SPECT) as reference. METHODS AND RESULTS: Patients underwent CZT-SPECT within 3 months of coronary angiography were included. Angio-FFR computation was performed using computational fluid dynamics. Percent diameter (%DS) and area stenosis (%AS) were measured by quantitative coronary angiography. Myocardial ischemia was defined as a summed difference score ≥ 2 in a vascular territory. Angio-FFR ≤ 0.80 was considered abnormal. 282 coronary arteries in 131 patients were analyzed. Overall accuracy of angio-FFR to detect ischemia on CZT-SPECT was 90.43%, with a sensitivity of 62.50% and a specificity of 98.62%. The diagnostic performance (= area under ROC = AUC) of angio-FFR [AUC = 0.91, 95% confidence intervals (CI) 0.86-0.95] was similar as those of %DS (AUC = 0.88, 95% CI 0.84-0.93, p = 0.326) and %AS (AUC = 0.88, 95% CI 0.84-0.93 p = 0.241) by 3D-QCA, but significantly higher than those of %DS (AUC = 0.59, 95% CI 0.51-0.67, p < 0.001) and %AS (AUC = 0.59, 95% CI 0.51-0.67, p < 0.001) by 2D-QCA. However, in vessels with 50-70% stenoses, AUC of angio-FFR was significantly higher than those of %DS (0.80 vs. 0.47, p < 0.001) and %AS (0.80 vs. 0.46, p < 0.001) by 3D-QCA and %DS (0.80 vs. 0.66, p = 0.036) and %AS (0.80 vs. 0.66, p = 0.034) by 2D-QCA. CONCLUSION: Angio-FFR had a high accuracy in predicting myocardial ischemia assessed by CZT-SPECT, which is similar as 3D-QCA but significantly higher than 2D-QCA. While in intermediate lesions, angio-FFR is better than 3D-QCA and 2D-QCA in assessing myocardial ischemia.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Humanos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Isquemia Miocárdica/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Constrição Patológica , Índice de Gravidade de Doença , Valor Preditivo dos Testes
10.
Sensors (Basel) ; 23(4)2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36850765

RESUMO

Radiation detectors based on Cadmium Zinc Telluride (CZT) compounds are becoming popular solutions thanks to their high detection efficiency, room temperature operation, and to their reliability in compact detection systems for medical, astrophysical, or industrial applications. However, despite a huge effort to improve the technological process, CZT detectors' full potential has not been completely exploited when both high spatial and energy resolution are required by the application, especially at low energies (<10 keV), limiting their application in energy-resolved photon counting (ERPC) systems. This gap can also be attributed to the lack of dedicated front-end electronics which can bring out the best in terms of detector spectroscopic performances. In this work, we present the latest results achieved in terms of energy resolution using SIRIO, a fast low-noise charge sensitive amplifier, and a linear-array pixel detector, based on boron oxide encapsulated vertical Bridgman-grown B-VB CZT crystals. The detector features a 0.25-mm pitch, a 1-mm thickness and is operated at a -700-V bias voltage. An equivalent noise charge of 39.2 el. r.m.s. (corresponding to 412 eV FWHM) was measured on the test pulser at 32 ns peaking time, leading to a raw resolution of 1.3% (782 eV FWHM) on the 59 keV line at room temperature (+20 °C) using an uncollimated 241Am, largely improving the current state of the art for CZT-based detection systems at such short peaking times, and achieving an optimum resolution of 0.97% (576 eV FWHM) at 1 µs peaking time. The measured energy resolution at the 122 keV line and with 1 µs peaking time of a 57Co raw uncollimated spectrum is 0.96% (1.17 keV). These activities are in the framework of an Italian collaboration on the development of energy-resolved X-ray scanners for material recycling, medical applications, and non-destructive testing in the food industry.

11.
Sensors (Basel) ; 23(6)2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36991907

RESUMO

The spectroscopic and imaging performance of energy-resolved photon counting detectors, based on new sub-millimetre boron oxide encapsulated vertical Bridgman cadmium zinc telluride linear arrays, are presented in this work. The activities are in the framework of the AVATAR X project, planning the development of X-ray scanners for contaminant detection in food industry. The detectors, characterized by high spatial (250 µm) and energy (<3 keV) resolution, allow spectral X-ray imaging with interesting image quality improvements. The effects of charge sharing and energy-resolved techniques on contrast-to-noise ratio (CNR) enhancements are investigated. The benefits of a new energy-resolved X-ray imaging approach, termed window-based energy selecting, in the detection of low- and high-density contaminants are also shown.

12.
Sensors (Basel) ; 23(10)2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37430504

RESUMO

Estimating accurate radiation doses when a radioactive source's location is unknown can protect workers from radiation exposure. Unfortunately, depending on a detector's shape and directional response variations, conventional G(E) function can be prone to inaccurate dose estimations. Therefore, this study estimated accurate radiation doses regardless of source distributions, using the multiple G(E) function groups (i.e., pixel-grouping G(E) functions) within a position-sensitive detector (PSD), which records the response position and energy inside the detector. Investigations revealed that, compared with the conventional G(E) function when source distributions are unknown, this study's proposed pixel-grouping G(E) functions improved dose estimation accuracy by more than 1.5 times. Furthermore, although the conventional G(E) function produced substantially larger errors in certain directions or energy ranges, the proposed pixel-grouping G(E) functions estimate doses with more uniform errors at all directions and energies. Therefore, the proposed method estimates the dose with high accuracy and provides reliable results regardless of the location and energy of the source.

13.
Eur J Nucl Med Mol Imaging ; 49(4): 1223-1231, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34655307

RESUMO

PURPOSE: Our study assesses the routine reporting of exercise ischemia using very low-dose exercise-first myocardial perfusion SPECT in a large number of patients and under real-life conditions, by evaluating correlations with the subsequent routine reporting of coronary stenosis by angiography and with factors that predict ischemia. METHODS: Data from 13,126 routine exercise MPI reports, from 11,952 patients (31% women), using very low doses of sestamibi and a high-sensitivity cardiac CZT camera, were extracted to assess the reporting of significant MPI-ischemia (> 1 left ventricular segment), to determine the MPI normalcy rate in a group with < 5% pretest probability of coronary artery disease (CAD) (n = 378), and to assess the ability of MPI to predict a > 50% coronary stenosis in patients with available coronary angiography reports in the 3 months after the MPI (n = 713). RESULTS: The median effective patient dose was 2.51 [IQR: 1.00-4.71] mSv. The normalcy rate was 98%, and the MPI-ischemia rate was independently predicted by a known CAD, the male gender, obesity, and a < 50% LV ejection fraction, ranging from 29.5% with all these risk factors represented to 1.5% when there were no risk factors. A > 50% coronary stenosis was significantly predicted by MPI-ischemia, less significantly for mild (odds ratio [95% confidence interval]: 1.61 [1.26-1.96]) than for moderate-to-severe MPI-ischemia (4.05 [3.53-4.57]) and was also impacted by having a known CAD (2.17 [1.83-2.51]), by a submaximal exercise test (1.48 [1.15-1.81]) and being ≥ 65 years of age (1.43 [1.11-1.76]). CONCLUSION: Ischemia detected using a very low-dose exercise-first MPI protocol in a large-scale clinical cohort and under real-life routine conditions is a highly significant predictor for the subsequent reporting of coronary stenosis, although this prediction is enhanced by other variables. This weakly irradiating approach is amenable to being repeated at shorter time intervals, in target patient groups with a high probability of MPI-ischemia.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Imagem de Perfusão do Miocárdio , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Teste de Esforço/métodos , Feminino , Humanos , Masculino , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Tomografia Computadorizada de Emissão de Fóton Único/métodos
14.
J Nucl Cardiol ; 29(2): 506-514, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-32715418

RESUMO

BACKGROUND: The aim of this study was to investigate the feasibility of assessing absolute myocardial 99mTc-HMDP uptake in patients with suspected cardiac ATTR using SUV with a whole-body CZT SPECT-CT camera (DNM670CZT). METHODS: Fifteen patients with suspected cardiac ATTR (Perugini ≥ 2) underwent a conventional 99mTc-HMDP planar imaging and a thoracic SPECT/CT using a DNM 670CZT. A control group consisted of 15 patients with negative scintigraphy (Perugini < 2). SUVmax (mg·L-1) and percentage of injected dose (%ID) were calculated in a cardiac volume of interest (VOI) encompassing the left ventricle. VOIs were also placed in the lung, the right pectoris major, and the sternum. A heart-to-lung SUVmax ratio (HLR) was calculated. RESULTS: All ATTR patients demonstrated an increased cardiac HMDP SUVmax (12.2 ± 3.7 mg·L-1) vs controls (3.5 ± 1.2, P < .0001). Percentage of ID, pectoral uptake and HLR were significantly higher in the ATTR group (1.1 ± 0.3 vs 0.15 ± 0.8, P < .0001; 1.5 ± 0.3 vs 0.9 ± 0.3, P < .0001; 9.7 ± 3 vs 4.3 ± 2.2, P < .0001). Bone uptake was not statistically different between the two groups. CONCLUSION: This study demonstrated the feasibility of quantitative 99mTc-HMDP SUVmax measurement using a whole-body SPECT/CT CZT camera in patients with suspected cardiac ATTR.


Assuntos
Amiloidose , Pré-Albumina , Cádmio , Humanos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Telúrio , Zinco
15.
J Nucl Cardiol ; 29(4): 1686-1697, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34350553

RESUMO

BACKGROUND: With the appearance of cadmium-zinc-telluride (CZT) cameras, dynamic myocardial perfusion imaging (MPI) has been introduced, but comparable data to other MPI modalities, such as quantitative coronary angiography (CAG) with fractional flow reserve (FFR) and positron emission tomography (PET), are lacking. This study aimed to evaluate the diagnostic accuracy of dynamic CZT single-photon emission tomography (SPECT) in coronary artery disease compared to quantitative CAG, FFR, and PET as reference. MATERIALS AND METHODS: Different databases were screened for eligible citations performing dynamic CZT-SPECT against CAG, FFR, or PET. PubMed, OvidSP (Medline), Web of Science, the Cochrane Library, and EMBASE were searched on the 5th of July 2020. Studies had to meet the following pre-established inclusion criteria: randomized controlled trials, retrospective trails or observational studies relevant for the diagnosis of coronary artery disease, and performing CZT-SPECT and within half a year the methodological references. Studies which considered coronary stenosis between 50% and 70% as significant based only on CAG were excluded. Data extracted were sensitivity, specificity, likelihood ratios, and diagnostic odds ratios. Quality was assessed with QUADAS-2 and statistical analysis was performed using a bivariate model. RESULTS: Based on our criteria, a total of 9 studies containing 421 patients were included. For the assessment of CZT-SPECT, the diagnostic value pooled analysis with a bivariate model was calculated and yielded a sensitivity of 0.79 (% CI 0.73 to 0.85) and a specificity of 0.85 (95% CI 0.74 to 0.92). Diagnostic odds ratio (DOR) was 17.82 (95% CI 8.80 to 36.08, P < 0.001). Positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 3.86 (95% CI 2.76 to 5.38, P < 0.001) and 0.21 (95% CI 0.13 to 0.33, P < 0.001), respectively. CONCLUSION: Based on the results of the current systematic review and meta-analysis, dynamic CZT-SPECT MPI demonstrated a good sensitivity and specificity to diagnose CAD as compared to the gold standards. However, due to the heterogeneity of the methodologies between the CZT-SPECT MPI studies and the relatively small number of included studies, it warrants further well-defined study protocols.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Cádmio , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Imagem de Perfusão do Miocárdio/métodos , Estudos Retrospectivos , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X , Zinco
16.
J Nucl Cardiol ; 29(1): 113-122, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32651801

RESUMO

BACKGROUND: Regadenoson is a selective adenosine receptor agonist. It is currently unclear if the level of hyperemia differs between stress agents. We compared Myocardial Blood Flow (MBF) and Myocardial Flow Reserve (MFR) response on CZT-SPECT Myocardial Perfusion Imaging (MPI) to evaluate if dipyridamole and regadenoson could induce the same level of hyperemia. METHODS: 228 patients with dynamic CZT-SPECT MPI were retrospectively analyzed (66 patients stressed with regadenoson and 162 with dipyridamole) in terms of MBF and MFR. To rule out confounding factors, two groups of 41 patients were matched for clinical characteristics in a sub-analysis, excluding high cardiovascular risk patients. RESULTS: Overall stress MBF was higher in regadenoson patients (1.71 ± 0.73 vs. 1.44 ± 0.55 mL·min-1·g-1 for regadenoson and dipyridamole, respectively, p < .05). However, when confounding factors were ruled out, stress MBF (1.57 ± 0.56 vs. 1.61 ± 0.62 mL·min-1·g-1 for dipyridamole and regadenoson, respectively, p = .88) and MFR (2.62 ± 0.77 vs. 2.46 ± 0.76 for dipyridamole and regadenoson, respectively, p = .40) were not different between regadenoson and dipyridamole. CONCLUSIONS: Our results suggest that dipyridamole and regadenoson induce equivalent hyperemia in dynamic SPECT with similar stress MBF and MFR in comparable patients.


Assuntos
Hiperemia , Imagem de Perfusão do Miocárdio , Circulação Coronária , Dipiridamol/farmacologia , Humanos , Hiperemia/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Purinas , Pirazóis , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
17.
J Nucl Cardiol ; 29(1): 181-187, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32410056

RESUMO

BACKGROUND: Cadmium-Zinc-Telluride (CZT) technology allows use of low activities of radiopharmaceuticals. The aim was to verify the values of left ventricular volume parameters, obtained via ultra-low-dose thallium Single Photon Emission Computed Tomography (SPECT) using a CZT camera. METHODS AND RESULTS: Forty-five patients referred for an assessment of myocardial perfusion or viability imaging were examined using CZT-SPECT and 1.5 T magnetic resonance (MRI) scanner. The ultra-low-dose protocol with 0.5 Mbq 201-Tl per kg of body weight was used. The values of end-systolic (ESV) and end-diastolic volumes (EDV), left ventricular ejection fraction (EF) and myocardial mass (MM) were assessed using both techniques. A very good correlation was found between the EF, ESV, and EDV values assessed with CZT-SPECT and cardiac magnetic resonance MRI; the Pearson coefficients were 0.86, 0.95, and 0.91, respectively. A moderate correlation was found for myocardial mass, r = 0.57. Compared to MRI, SPECT systematically overestimated ESV and MM, while it underestimates the EF, with P ≤ .001 in all cases. There was no difference in EDV estimation. CONCLUSIONS: Left ventricular volumes and ejection fraction assessed via ultra-low-dose CZT-SPECT showed very good correlation with the values obtained by MRI. A moderate correlation was found for myocardial mass.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único , Função Ventricular Esquerda , Cádmio , Humanos , Imageamento por Ressonância Magnética/métodos , Volume Sistólico , Telúrio , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Zinco
18.
J Nucl Cardiol ; 29(3): 1051-1063, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33098073

RESUMO

BACKGROUND: The objective of this study was to evaluate the accuracy of global MBF and MFR quantitation performed by myocardial perfusion scintigraphy (MPS) for the detection of multivessel coronary artery disease (CAD). METHODS: 52 CAD patients underwent CZT MPS, with the evaluation of MBF and MFR, followed by invasive coronary angiography (ICA). According to MPS and ICA results, all patients were divided into three groups: (1) non-obstructive CAD and normal MPS scan (control group) (n = 7), (2) one vessel disease (1VD) (n = 16), (3) multivessel disease (MVD) (n = 29). RESULTS: Global absolute MBF and MFR were significantly reduced in MVD patients as compared to those with 1VD [0.93 (IQR 0.76; 1.39) vs 1.94 (1.37; 2.21) mL·min-1·g-1, P = .00012] and [1.4 (IQR 1.02; 1.85) vs 2.3 (1.8; 2.67), P = . 0 004], respectively. The Syntax score correlated with global stress MBF (ρ = - 0.64; P < .0001) and MFR (ρ = - 0.53; P = .0003). ROC analysis showed higher sensitivity and specificity for stress MBF and MFR compared with semiquantitative MPS stress evaluation. Multivariate regression analysis showed that only stress MBF [OR (95% CI) 0.59 (0.42-0.82); P < .0003] was an independent predictor of MVD. CONCLUSIONS: Quantitative myocardial blood flow values assessed with the use of CZT camera may identify high-risk patients, such as those with multivessel disease.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Doença da Artéria Coronariana/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X
19.
J Nucl Cardiol ; 29(6): 3137-3151, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-33939162

RESUMO

Cardiac PET-derived measurements of myocardial blood flow (MBF) and myocardial flow reserve (MFR) are proven robust indexes of the severity of coronary artery disease (CAD). They facilitate the diagnosis of diffuse epicardial and microvascular disease and are also of prognostic significance. However, low availability and high cost have limited their wide clinical implementation. Over the last 15 years, cadmium zinc telluride (CZT)-based detectors have been implemented into SPECT imaging devices. Myocardial perfusion scintigraphy can be performed faster and with less radiation exposure as compared with standard gamma cameras. Rapid dynamic SPECT studies with higher count rates can be performed. This technological breakthrough has renewed the interest in SPECT MBF assessment in patients with CAD. Currently, two cardiac-centered CZT gamma cameras are available commercially-Discovery NM530c and D-SPECT. They differ in parameters such as collimator design, number of detectors, sensitivity, spatial resolution and image reconstruction. A number of publications have focused on the feasibility of dynamic CZT SPECT and on the correlation with cardiac PET and invasive coronary angiography measurements of fractional flow reserve. Current study reviews the present status of MBF and MFR assessment with CZT SPECT. It also aims to provide an overview of specific issues related to acquisition, processing and interpretation of quantitative studies in patients with CAD.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Cádmio , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Telúrio , Zinco
20.
J Nucl Cardiol ; 29(4): 1995-2000, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-33977371

RESUMO

BACKGROUND: Bone scintigraphy is a main diagnostic tool in suspected ATTR patients. Almost all literature is based on conventional whole body gamma cameras, and there is very sparse data evaluating the use of dedicated cardiac CZT cameras. The aim of this study was to evaluate the utility of bone scintigraphy in suspected transthyretin cardiac amyloidosis (ATTR-CA) patients on a dedicated cardiac CZT camera. METHODS: Seventy-three patients with suspected ATTR-CA underwent planar and SPECT Tc-99 m pyrophosphate scintigraphy using dedicated cardiac CZT camera between May and August 2019. RESULTS: Planar D-SPECT image quality was mostly good. Six patients were identified as ATTR-CA positive. Inter-observer agreement based on both Perugini score and on planar D-SPECT H/CL ratio was excellent. CONCLUSIONS: ATTR-CA scintigraphy using dedicated cardiac CZT camera was feasible, and yielded planar D-SPECT images with excellent inter-observer agreement.


Assuntos
Amiloidose , Pré-Albumina , Amiloidose/diagnóstico por imagem , Humanos , Cintilografia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa