RESUMO
PURPOSE: This study aimed to assess the margin for the planning target volume (PTV) using the Van Herk formula. We then validated the proposed margin by real-time magnetic resonance imaging (MRI). METHODS: An analysis of cone-beam computed tomography (CBCT) data from early glottic cancer patients was performed to evaluate organ motion. Deformed clinical target volumes (CTV) after rigid registration were acquired using the Velocity program (Varian Medical Systems, Palo Alto, CA, USA). Systematic (Σ) and random errors (σ) were evaluated. The margin for the PTV was defined as 2.5â¯Σâ¯+ 0.7â¯σ according to the Van Herk formula. To validate this margin, we accrued healthy volunteers. Sagittal real-time cine MRI was conducted using the ViewRay system (ViewRay Inc., Oakwood Village, OH, USA). Within the obtained sagittal images, the vocal cord was delineated. The movement of the vocal cord was summed up and considered as the internal target volume (ITV). We then assessed the degree of overlap between the ITV and the PTV (vocal cord plus margins) by calculating the volume overlap ratio, represented as (ITVâ©PTV)/ITV. RESULTS: CBCTs of 17 early glottic patients were analyzed. Σ and σ were 0.55 and 0.57 for left-right (LR), 0.70 and 0.60 for anterior-posterior (AP), and 1.84 and 1.04 for superior-inferior (SI), respectively. The calculated margin was 1.8â¯mm (LR), 2.2â¯mm (AP), and 5.3â¯mm (SI). Four healthy volunteers participated for validation. A margin of 3â¯mm (AP) and 5â¯mm (SI) was applied to the vocal cord as the PTV. The average volume overlap ratio between ITV and PTV was 0.92 (range 0.85-0.99) without swallowing and 0.77 (range 0.70-0.88) with swallowing. CONCLUSION: By evaluating organ motion by using CBCT, the margin was 1.8 (LR), 2.2 (AP), and 5.3â¯mm (SI). The margin acquired using CBCT fitted well in real-time cine MRI. Given that swallowing during radiotherapy can result in a substantial displacement, it is crucial to consider strategies aimed at minimizing swallowing and related motion.
Assuntos
Tomografia Computadorizada de Feixe Cônico , Glote , Neoplasias Laríngeas , Imagem Cinética por Ressonância Magnética , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Imagem Cinética por Ressonância Magnética/métodos , Glote/diagnóstico por imagem , Masculino , Neoplasias Laríngeas/diagnóstico por imagem , Neoplasias Laríngeas/radioterapia , Pessoa de Meia-Idade , Feminino , Adulto , Idoso , Movimentos dos Órgãos , Sistemas Computacionais , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
AIM: To assess the feasibility of immediate (IIP), early (EIP) and delayed implant placement (DIP) for single tooth replacement in the premaxilla on the basis of the complete indication area of each approach in routine practice. MATERIALS AND METHODS: Data from 100 patients (59 women, 41 men, all Caucasians) aged between 19 and 81 years old (mean age 51.71) who had been consecutively treated with a single implant in the premaxilla (13-23) in one private periodontal practice were retrospectively collected. Demographic data, diagnostic information and linear measurements were extracted from patient files and CBCTs. The feasibility of IIP, EIP and DIP was assessed for all cases by both authors, based on the following criteria: availability of apical bone, position of the tooth in relation to the morphology of the alveolar process, buccal bone morphology and presence of midfacial recession. The reasons for not being able to perform an approach, and the viable alternatives for each approach were secondary outcomes. DIP was considered to have been preceded by alveolar ridge preservation (ARP). RESULTS: Ninety-two patients could be treated by means of IIP, EIP or DIP. In eight patients none of these approaches were possible as they required bone augmentation prior to implant placement. Fifty-two patients (95% CI: 42%-62%) could by treated with IIP, 58 (95% CI: 48%-67%) with EIP and 88 (95% CI: 80%-93%) with DIP. The feasibility proportions of IIP and EIP were significantly lower than the one of DIP (p < 0.001). All patients who could be treated with IIP could also be treated with EIP or DIP. Lack of apical bone for implant anchorage was the main reason for not being able to perform IIP and EIP. Complete loss of the buccal bone wall and the need for bone augmentation prior to implant placement were the reasons for not being able to perform DIP. CONCLUSION: From the results of this retrospective CBCT analysis, DIP is nearly always possible in contrast to IIP and EIP. Therefore, and since it is much easier than IIP and EIP, inexperienced clinicians should mainly focus on ARP and DIP in clinical practice deferring IIP and EIP until more surgical skills have been acquired.
RESUMO
BACKGROUND: Weight bearing computed tomography (WBCT) utilizes cone beam CT technology to provide assessments of lower limb joint structures while they are functionally loaded. Grey-scale values indicative of X-ray attenuation that are output from cone beam CT are challenging to calibrate, and their use for bone mineral density (BMD) measurement remains debatable. To determine whether WBCT can be reliably used for cortical and trabecular BMD assessment, we sought to establish the accuracy of BMD measurements at the knee using modern WBCT by comparing them to measurements from conventional CT. METHODS: A hydroxyapatite phantom with three inserts of varying densities was used to systematically quantify signal uniformity and BMD accuracy across the acquisition volume. We evaluated BMD in vivo (nâ¯=â¯5, female) using synchronous and asynchronous calibration techniques in WBCT and CT. To account for variation in attenuation along the height (z-axis) of acquisition volumes, we tested a height-dependent calibration approach for both WBCT and CT images. RESULTS: Phantom BMD measurement error in WBCT was as high as 15.3% and consistently larger than CT (up to 5.6%). Phantom BMD measures made under synchronous conditions in WBCT improved measurement accuracy by up to 3% but introduced more variability in measured BMD. We found strong correlations (Râ¯=â¯0.96) as well as wide limits of agreement (-324 mgHA/cm3 to 183 mgHA/cm3) from Bland-Altman analysis between WBCT and CT measures in vivo that were not improved by height-dependent calibration. CONCLUSION: Whilst BMD accuracy from WBCT was found to be dependent on apparent density, accuracy was independent of the calibration technique (synchronous or asynchronous) and the location of the measurement site within the field of view. Overall, we found strong correlations between BMD measures from WBCT and CT and in vivo measures to be more accurate in trabecular bone regions. Importantly, WBCT can be used to distinguish between anatomically relevant differences in BMD, however future work is necessary to determine the repeatability and sensitivity of BMD measures in WBCT.
Assuntos
Densidade Óssea , Tomografia Computadorizada de Feixe Cônico , Imagens de Fantasmas , Suporte de Carga , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Feminino , Calibragem , Pessoa de Meia-Idade , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiologia , Reprodutibilidade dos Testes , Osso Esponjoso/diagnóstico por imagem , Idoso , Absorciometria de Fóton/métodosRESUMO
INTRODUCTION: The investigation of peripheral pulmonary lesions (PPLs) can be challenging. Several bronchoscopic modalities have been developed to reach and biopsy PPL but the level of adoption of these techniques by interventional pulmonologists (IPs) is unknown. This international survey was conducted to describe current practices in PPL investigation among IP. METHODS: This survey was sent to all members of the World Association for Bronchology and Interventional Pulmonology, Canadian Thoracic Society Procedures Assembly, AABIP, and the Groupe d'Endoscopie Thoracique et Interventionnel Francophone. The survey was composed of 48 questions and three clinical cases to establish a portrait of modalities used to investigate and treat PPL by IP around the world. RESULTS: Three hundred and twelve IP responded to the survey. Most of them practice in Europe (n = 122), North America (n = 97), and Asia (n = 49). Half of responders perform more than 100 endoscopic procedures for PPL annually. General anesthesia and conscious sedation are used in similar proportions (53% and 47%, respectively). Rapid on site evaluation (ROSE) is used when sampling PPL by 42%. Radial EBUS (69%), fluoroscopy (55%), and electromagnetic navigation (27%) are the most widely used techniques. Most IP combine techniques (89%). Robotic bronchoscopy (15%) and cone-beam CT (8%) are almost exclusively used in the USA where, respectively, 60% and 37% of respondents reported using these modalities. Ten percent of IP currently had access to endoscopic treatment modalities for PPL. However, half of the remaining IP plan to acquire an endoscopic treatment modality in the next 2 years. CONCLUSION: Available techniques and practices worldwide vary significantly regarding PPL investigation and treatment.
Assuntos
Pneumopatias , Neoplasias Pulmonares , Humanos , Pneumopatias/patologia , Neoplasias Pulmonares/patologia , Broncoscopia/métodos , Canadá , Inquéritos e QuestionáriosRESUMO
BACKGROUND: Cone-beam computed tomography (CBCT) has been introduced for breast-specimen imaging to identify a free resection margin of abnormal tissues in breast conservation. As well-known, typical micro CT consumes long acquisition and computation times. One simple solution to reduce the acquisition scan time is to decrease of the number of projections, but this method generates streak artifacts on breast specimen images. Furthermore, the presence of a metallic-needle marker on a breast specimen causes metal artifacts that are prominently visible in the images. In this work, we propose a deep learning-based approach for suppressing both streak and metal artifacts in CBCT. METHODS: In this work, sinogram datasets acquired from CBCT and a small number of projections containing metal objects were used. The sinogram was first modified by removing metal objects and up sampling in the angular direction. Then, the modified sinogram was initialized by linear interpolation and synthesized by a modified neural network model based on a U-Net structure. To obtain the reconstructed images, the synthesized sinogram was reconstructed using the traditional filtered backprojection (FBP) approach. The remaining residual artifacts on the images were further handled by another neural network model, ResU-Net. The corresponding denoised image was combined with the extracted metal objects in the same data positions to produce the final results. RESULTS: The image quality of the reconstructed images from the proposed method was improved better than the images from the conventional FBP, iterative reconstruction (IR), sinogram with linear interpolation, denoise with ResU-Net, sinogram with U-Net. The proposed method yielded 3.6 times higher contrast-to-noise ratio, 1.3 times higher peak signal-to-noise ratio, and 1.4 times higher structural similarity index (SSIM) than the traditional technique. Soft tissues around the marker on the images showed good improvement, and the mainly severe artifacts on the images were significantly reduced and regulated by the proposed. CONCLUSIONS: Our proposed method performs well reducing streak and metal artifacts in the CBCT reconstructed images, thus improving the overall breast specimen images. This would be beneficial for clinical use.
Assuntos
Aprendizado Profundo , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Artefatos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/métodos , Microtomografia por Raio-X , AlgoritmosRESUMO
PURPOSE: Determining the cause of interstitial lung disease (ILD) remains challenging. While surgical lung biopsy remains the gold standard approach, risks associated with it may be prohibitive. Transbronchial lung cryobiopsy (TBLC) is a minimally invasive alternative with an improved safety profile and acceptable diagnostic accuracy. We retrospectively assessed whether the use of Cone Beam computed tomography guidance for TBLC (TBLC-CBCT) improves safety and diagnostic yield compared to performing TBLC with fluoroscopic guidance (TBLC-F). METHODS: A retrospective cohort review of 120 patients presenting for evaluation of newly diagnosed ILD was performed. Demographic data, pulmonary function test values, chest imaging pattern, procedural information, and final multidisciplinary discussion (MDD) diagnosis were recorded. RESULTS: 62 patients underwent TBLC-F and 58 underwent TBLC-CBCT. Patients undergoing TBLC-CBCT were older (67.86 ± 10.97 vs 61.45 ± 12.77 years, p = 0.004) and had a higher forced vital capacity percent predicted (73.80 ± 17.32% vs 66.00 ± 17.45%, p = 0.03) compared to the TBLC-F group. The average probe-to-pleura distance was 5.1 ± 2.3 mm in the TBLC-CBCT group with 4.0 ± 0.3 CBCT spins performed. Pneumothorax occurred more often in the TBLC-F group (n = 6, 9.7%) compared to the TBLC-CBCT group (n = 1, 1.7%, p = 0.06). Grade 2 bleeding only occurred in the TBLC-F group (n = 4, 6.5%). A final MDD diagnosis was obtained in 89% (n = 57) of TBLC-F patients and 95% (n = 57) of TBLC-CBCT patients. CONCLUSIONS: TBLC-CBCT appears to be safer compared to TBLC-F with both approaches facilitating an MDD diagnosis. Further studies from multiple institutions randomizing patients to each modality are needed to confirm these findings.
Assuntos
Biópsia , Doenças Pulmonares Intersticiais , Humanos , Biópsia/efeitos adversos , Biópsia/métodos , Tomografia Computadorizada de Feixe Cônico , Fluoroscopia , Pulmão/diagnóstico por imagem , Pulmão/patologia , Doenças Pulmonares Intersticiais/diagnóstico , Estudos RetrospectivosRESUMO
OBJECTIVE: This study aimed to assess the incidence and clinical significance of pneumothorax (PTX) and pulmonary hemorrhage (PH) after percutaneous transthoracic lung biopsy (PTLB) guided by C-arm cone-beam computed tomography (CBCT). Furthermore, this study aimed to examine the relationships between PTX and PH with demographics, clinical characteristics, imaging, and PTLB parameters. METHODS: A retrospective analysis was conducted on 192 patients who underwent PTLB at our hospital between January 2019 and October 2022. Incidences of PTX and PH were recorded. PTX was considered clinically significant if treated with chest tube insertion (CTI), and PH if treated with bronchoscopes or endovascular treatments. The various factors on PTX and PH were analyzed using the Chi-squared test and Student t-test. Logistic regression analyses were then used to determine these factors on the correlation to develop PTX and PH. RESULTS: PTX occurred in 67/192 cases (34.9%); CTI was required in 5/67 (7.5%). PH occurred in 63/192 cases (32.8%) and none of these cases required bronchoscopes or endovascular treatments. Lesion diameter (ORPTX = 0.822; ORPH = 0.785), presence of pulmonary emphysema (ORPH = 2.148), the number of samples (ORPH = 1.834), the use of gelfoam (ORPTX = 0.474; ORPH = 0.341) and ablation (ORPTX = 2.351; ORPH = 3.443) showed statistically significant correlation to PTX and PH. CONCLUSIONS: CBCT-guided PTLB is a safe and effective method for performing lung biopsies. The use of gelfoam has been shown to reduce the occurrence of PTX and PH. However, caution should be exercised when combining radiofrequency ablation with PTLB, as it may increase the risk of PTX and PH.
Assuntos
Pneumopatias , Pneumotórax , Humanos , Pneumotórax/epidemiologia , Pneumotórax/etiologia , Pneumotórax/patologia , Incidência , Estudos Retrospectivos , Relevância Clínica , Pulmão/diagnóstico por imagem , Pulmão/patologia , Pneumopatias/diagnóstico por imagem , Pneumopatias/epidemiologia , Pneumopatias/complicações , Tomografia Computadorizada de Feixe Cônico , Hemorragia/epidemiologia , Hemorragia/etiologia , Biópsia por Agulha/efeitos adversos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Fatores de RiscoRESUMO
OBJECTIVE: Transbronchial biopsy is a safe manner with fewer complications than percutaneous transthoracic needle biopsy; however, the current diagnostic yield is still necessitating further improvement. We aimed to evaluate the diagnostic yield of using virtual bronchoscopic navigation (VBN) and cone-beam CT (CBCT) for transbronchial biopsy and to investigate the factors that affected the diagnostic sensitivity. METHODS: We retrospectively investigated 255 patients who underwent VBN-CBCT-guided transbronchial biopsy at our two centers from May 2021 to April 2022. A total of 228 patients with final diagnoses were studied. Patient characteristics including lesion size, lesion location, presence of bronchus sign, lesion type and imaging tool used were collected and analyzed. Diagnostic yield was reported overall and in groups using different imaging tools. RESULTS: The median size of lesion was 21 mm (range of 15.5-29 mm) with 46.1% less than 2 cm in diameter. Bronchus sign was present in 87.7% of the patients. The overall diagnostic yield was 82.1%, and sensitivity for malignancy was 66.3%. Patients with lesion > 2 cm or with bronchus sign were shown to have a significantly higher diagnostic yield. Four patients had bleeding and no pneumothorax occurred. CONCLUSION: Guided bronchoscopy with VBN and CBCT was an effective diagnostic method and was associated with a high diagnostic yield in a safe manner. In addition, the multivariant analysis suggested that lesion size and presence of bronchus sign could be a predictive factor for successful bronchoscopic diagnosis.
Assuntos
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Estudos Retrospectivos , Biópsia/métodos , Tomografia Computadorizada de Feixe Cônico , Brônquios/patologia , Broncoscopia/métodosRESUMO
Computed tomography (CT) is a common modality employed for musculoskeletal imaging. Conventional CT techniques are useful for the assessment of trauma in detection, characterization and surgical planning of complex fractures. CT arthrography can depict internal derangement lesions and impact medical decision making of orthopedic providers. In oncology, CT can have a role in the characterization of bone tumors and may elucidate soft tissue mineralization patterns. Several advances in CT technology have led to a variety of acquisition techniques with distinct clinical applications. These include four-dimensional CT, which allows examination of joints during motion; cone-beam CT, which allows examination during physiological weight-bearing conditions; dual-energy CT, which allows material decomposition useful in musculoskeletal deposition disorders (e.g., gout) and bone marrow edema detection; and photon-counting CT, which provides increased spatial resolution, decreased radiation, and material decomposition compared to standard multi-detector CT systems due to its ability to directly translate X-ray photon energies into electrical signals. Advanced acquisition techniques provide higher spatial resolution scans capable of enhanced bony microarchitecture and bone mineral density assessment. Together, these CT acquisition techniques will continue to play a substantial role in the practices of orthopedics, rheumatology, metabolic bone, oncology, and interventional radiology.
Assuntos
Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Doenças Musculoesqueléticas/diagnóstico por imagem , Sistema Musculoesquelético/diagnóstico por imagemRESUMO
PURPOSE: To evaluate the feasibility of an open-source, semi-automated, and reproducible vertex placement tool to improve the efficiency of lattice radiotherapy (LRT) planning. We used polymer gel dosimetry with a Cone Beam CT (CBCT) readout to commission this LRT technique. MATERIAL AND METHODS: We generated a volumetric modulated arc therapy (VMAT)-based LRT plan on a 2 L NIPAM polymer gel dosimeter using our Eclipse Acuros version 15.6 AcurosXB beam model, and also recalculated the plan with a pre-clinical Acuros v18.0 dose calculation algorithm with the enhanced leaf modelling (ELM). With the assistance of the MAAS-SFRThelper software, a lattice vertex diameter of 1.5 cm and center-to-center spacing of 3 cm were used to place the spheres in a hexagonal, closed packed structure. The verification plan included four gantry arcs with 15°, 345°, 75°, 105° collimator angles. The spheres were prescribed 20 Gy to 50% of their combined volume. The 6 MV Flattening Filter Free beam energy was used to deliver the verification plan. The dosimetric accuracy of the LRT delivery was evaluated with 1D dose profiles, 2D isodose maps, and a 3D global gamma analysis. RESULTS: Qualitative comparisons between the 1D dose profiles of the Eclipse plan and measured gel showed good consistency at the prescription dose mark. The average diameter measured 13.3 ± 0.2 mm (gel for v15.6), 12.6 mm (v15.6 plan), 13.1 ± 0.2 mm (gel for v18.0), and 12.3 mm (v18.0 plan). 3D gamma analysis showed that all gamma pass percent were > 95% except at 1% and 2% at the 1 mm distance to agreement criteria. CONCLUSION: This study presents a novel application of gel dosimetry in verifying the dosimetric accuracy of LRT, achieving excellent 3D gamma results. The treatment planning was facilitated by publicly available software that automatically placed the vertices for consistency and efficiency.
RESUMO
PURPOSE: The presence of metal implants can produce artifacts and distort Hounsfield units (HU) in patient computed tomography (CT) images. The purpose of this work was to characterize a novel metal artifact reduction (MAR) algorithm for reconstruction of CBCT images obtained by the HyperSight imaging system. METHODS: Three tissue-equivalent phantoms were fitted with materials commonly used in medical applications. The first consisted of a variety of metal samples centered within a solid water block, the second was an Advanced Electron Density phantom with metal rods, and the third consisted of hip prostheses positioned within a water tank. CBCT images of all phantoms were acquired and reconstructed using the MAR and iCBCT Acuros algorithms on the HyperSight system. The signal-to-noise ratio (SNR), artifact index (AI), structural similarity index measure (SSIM), peak signal-to-noise ratio (PSNR), and mean-square error (MSE) were computed to assess the image quality in comparison to artifact-free reference images. The mean HU at various VOI positions around the cavity was calculated to evaluate the artifact dependence on distance and angle from the center of the cavity. The artifact volume of the phantom (excluding the cavity) was estimated by summing the volume of all voxels with HU values outside the 5th and 95th percentiles of the phantom CBCT with no artifact. RESULTS: The SNR, AI, SSIM, PSNR, and MSE metrics demonstrated significantly higher similarity to baseline when using MAR compared to iCBCT Acuros for all high-density materials, except for aluminum. Mean HU returned to expected solid water background at a shorter distance from metal sample in the MAR images, and the standard deviation remained lower for the MAR images at all distances from the insert. The artifact volume decreased using the novel MAR algorithm for all metal samples excluding aluminum (p < 0.001) and all hip prostheses (p < 0.05). CONCLUSION: Varian's HyperSight MAR reconstruction algorithm shows a reduction in metal artifact metrics, motivating the use of MAR reconstruction for patients with metal implants.
RESUMO
PURPOSE: Histotripsy is a nonionizing, noninvasive, and nonthermal focal tumor therapy. Cone-beam computed tomography (CBCT) guidance was developed for targeting tumors not visible on ultrasound. This approach assumes cavitation is formed at the geometrical focal point of the therapy transducer. In practice, the exact location might vary slightly between transducers. In this study, we present a phantom with an embedded target to evaluate CBCT-guided histotripsy accuracy and assess the completeness of treatments. METHODS: Spherical (2.8 cm) targets with alternating layers of agar and radiopaque barium were embedded in larger phantoms with similar layers. The layer geometry was designed so that targets were visible on pre-treatment CBCT scans. The actual histotripsy treatment zone was visualized via the mixing of adjacent barium and agar layers in post-treatment CBCT images. CBCT-guided histotripsy treatments of the targets were performed in six phantoms. Offsets between planned and actual treatment zones were measured and used for calibration refinement. To measure targeting accuracy after calibration refinement, six additional phantoms were treated. In a separate investigation, two groups (N = 3) of phantoms were treated to assess visualization of incomplete treatments ("undertreatment" group: 2 cm treatment within 2.8 cm tumor, "mistarget" group: 2.8 cm treatment intentionally shifted laterally). Treatment zones were segmented (3D Slicer 5.0.3), and the centroid distance between the prescribed target and actual treatment zones was quantified. RESULTS: In the calibration refinement group, a 2 mm offset in the direction of ultrasound propagation (Z) was measured. After calibration refinement, the centroid-to-centroid distance between prescribed and actual treatment volumes was 0.5 ± 0.2 mm. Average difference between the prescribed and measured treatment sizes in the incomplete treatment groups was 0.5 ± 0.7 mm. In the mistarget group, the distance between prescribed and measured shifts was 0.2 ± 0.1 mm. CONCLUSION: The proposed prototype phantom allowed for accurate measurement of treatment size and location, and the CBCT visible target provided a simple way to detect misalignments for preliminary quality assurance of CBCT-guided histotripsy.
Assuntos
Tomografia Computadorizada de Feixe Cônico , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapiaRESUMO
OBJECTIVE: This study aims to analyze setup errors in pelvic Volumetric Modulated Arc Therapy (VMAT) for patients with non-surgical primary cervical cancer, utilizing the onboard iterative kV cone beam CT (iCBCT) imaging system on the Varian Halcyon 2.0 ring gantry structure accelerator to enhance radiotherapy precision. METHOD: We selected 132 cervical cancer patients who underwent VMAT with daily iCBCT imaging guidance. Before each treatment session, a registration method based on the bony structure was employed to acquire iCBCT images with the corresponding planning CT images. Following verification and adjustment of image registration results along the three axes (but not rotational), setup errors in the lateral (X-axis), longitudinal (Y-axis), and vertical (Z-axis) directions were recorded for each patient. Subsequently, we analyzed 3642 iCBCT image setup errors. RESULTS: The mean setup errors for the X, Y, and Z axes were 4.50 ± 3.79 mm, 6.08 ± 6.30 mm, and 1.48 ± 2.23 mm, respectively. Before correction with iCBCT, setup margins based on the Van Herk formula for the X, Y, and Z axes were 6.28, 12.52, and 3.26 mm, respectively. In individuals aged 60 years and older, setup errors in the X and Y axes were significantly larger than those in the younger group (p < 0.05). Additionally, there is no significant linear correlation between setup errors and treatment fraction numbers. CONCLUSION: Data analysis underscores the importance of precise Y-axis setup for cervical cancer patients undergoing VMAT. Radiotherapy centers without daily iCBCT should appropriately extend the planning target volume (PTV) along the Y-axis for cervical cancer patients receiving pelvic VMAT. Elderly patients exhibit significantly larger setup errors compared to younger counterparts. In conclusion, iCBCT-guided radiotherapy is recommended for cervical cancer patients undergoing VMAT to improve setup precision.
Assuntos
Tomografia Computadorizada de Feixe Cônico , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Erros de Configuração em Radioterapia , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Humanos , Feminino , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/diagnóstico por imagem , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Pessoa de Meia-Idade , Erros de Configuração em Radioterapia/prevenção & controle , Idoso , Adulto , Processamento de Imagem Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Idoso de 80 Anos ou mais , Órgãos em Risco/efeitos da radiação , Aceleradores de Partículas/instrumentação , PrognósticoRESUMO
The purpose of this study is to compare the subjective and objective quality and confidence between conventional angiography with cone-beam computed tomography (CBCT) and magnetic resonance imaging (MRI) for the preoperative evaluation of potential donors for living donor liver transplant. Seventeen patients undergoing preoperative donor evaluation for living donor liver transplantation that underwent angiography with CBCT and contrast-enhanced MRI for evaluation of hepatic vascular anatomy were included in the study. Four attending radiologists interpreted anonymized, randomized angiography with CBCT images and MRIs, rating the diagnostic quality and confidence of their interpretation (on a 3-point scale) for each element, as well as clinically relevant measurements. Overall, the readers rated the quality of angiography with CBCT to be higher than that of MRI (median [interquartile range] = 3 (2, 3) vs. 2 (1-3), p < 0.001) across all patients. Readers of angiography with CBCT had more confidence in their interpretations as an average of all elements evaluated than the MRI readers (3 (3) vs. 3 (2, 3), p < 0.001). When the same reader interpreted both MRI and CBCT, the right hepatic artery diameter (3.8 mm ± 0.72 mm vs. 4.5 mm ± 1.2 mm, p < 0.005) and proper hepatic artery diameter (4.43 mm ± 0.98 mm vs. 5.4 mm ± 1.05 mm, p < 0.003) were significantly different between MRI and CBCT. There was poor interrater reliability for determining segment IV arterial supply for both modalities (κ < 0.2). Angiography with CBCT provides higher subjective diagnostic quality and greater radiologist confidence than MRI. The difference in measurements between CBCT and MRI when the same reader reads both studies suggests CBCT adds additional information over MRI evaluation alone.
Assuntos
Transplante de Fígado , Humanos , Doadores Vivos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética , Angiografia , Tomografia Computadorizada de Feixe Cônico/métodosRESUMO
OBJECTIVES: To develop and validate a modified deep learning (DL) model based on nnU-Net for classifying and segmenting five-class jaw lesions using cone-beam CT (CBCT). METHODS: A total of 368 CBCT scans (37 168 slices) were used to train a multi-class segmentation model. The data underwent manual annotation by two oral and maxillofacial surgeons (OMSs) to serve as ground truth. Sensitivity, specificity, precision, F1-score, and accuracy were used to evaluate the classification ability of the model and doctors, with or without artificial intelligence assistance. The dice similarity coefficient (DSC), average symmetric surface distance (ASSD), and segmentation time were used to evaluate the segmentation effect of the model. RESULTS: The model achieved the dual task of classifying and segmenting jaw lesions in CBCT. For classification, the sensitivity, specificity, precision, and accuracy of the model were 0.871, 0.974, 0.874, and 0.891, respectively, surpassing oral and maxillofacial radiologists (OMFRs) and OMSs, approaching the specialist. With the model's assistance, the classification performance of OMFRs and OMSs improved, particularly for odontogenic keratocyst (OKC) and ameloblastoma (AM), with F1-score improvements ranging from 6.2% to 12.7%. For segmentation, the DSC was 87.2% and the ASSD was 1.359 mm. The model's average segmentation time was 40 ± 9.9 s, contrasting with 25 ± 7.2 min for OMSs. CONCLUSIONS: The proposed DL model accurately and efficiently classified and segmented five classes of jaw lesions using CBCT. In addition, it could assist doctors in improving classification accuracy and segmentation efficiency, particularly in distinguishing confusing lesions (eg, AM and OKC).
Assuntos
Tomografia Computadorizada de Feixe Cônico , Aprendizado Profundo , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Sensibilidade e Especificidade , Neoplasias Maxilomandibulares/diagnóstico por imagem , Neoplasias Maxilomandibulares/classificação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doenças Maxilomandibulares/diagnóstico por imagem , Doenças Maxilomandibulares/classificaçãoRESUMO
OBJECTIVES: In order to assist junior doctors in better diagnosing apical periodontitis (AP), an artificial intelligence AP grading system was developed based on deep learning (DL) and its reliability and accuracy were evaluated. METHODS: One hundred and twenty cone-beam computed tomography (CBCT) images were selected to construct a classification dataset with four categories, which were divided by CBCT periapical index (CBCTPAI), including normal periapical tissue, CBCTPAI 1-2, CBCTPAI 3-5, and young permanent teeth. Three classic algorithms (ResNet50/101/152) as well as one self-invented algorithm (PAINet) were compared with each other. PAINet were also compared with two recent Transformer-based models and three attention models. Their performance was evaluated by accuracy, precision, recall, balanced F score (F1-score), and the area under the macro-average receiver operating curve (AUC). Reliability was evaluated by Cohen's kappa to compare the consistency of model predicted labels with expert opinions. RESULTS: PAINet performed best among the four algorithms. The accuracy, precision, recall, F1-score, and AUC on the test set were 0.9333, 0.9415, 0.9333, 0.9336, and 0.9972, respectively. Cohen's kappa was 0.911, which represented almost perfect consistency. CONCLUSIONS: PAINet can accurately distinguish between normal periapical tissues, CBCTPAI 1-2, CBCTPAI 3-5, and young permanent teeth. Its results were highly consistent with expert opinions. It can help junior doctors diagnose and score AP, reducing the burden. It can also be promoted in areas where experts are lacking to provide professional diagnostic opinions.
Assuntos
Algoritmos , Inteligência Artificial , Tomografia Computadorizada de Feixe Cônico , Periodontite Periapical , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Periodontite Periapical/diagnóstico por imagem , Reprodutibilidade dos Testes , Aprendizado ProfundoRESUMO
OBJECTIVES: This study aimed to assess the accuracy of ultra-low dose (ULD) cone-beam CT (CBCT) for detection of proximal caries. METHODS: This in vitro study evaluated 104 molar and premolar teeth. The teeth were mounted in dry skulls and underwent CBCT with 4 protocols of high-resolution (HR), normal (NORM), ULD-HR, and ULD-NORM; 78 CBCT images were scored by 3 observers for the presence and penetration depth of caries twice with a 2-week interval using a 5-point Likert scale. The teeth were then sectioned and observed under a stereomicroscope (gold standard). The 4 protocols were compared with each other and with the gold standard. The receiver operating characteristic curve was drawn, and the area under the curve (AUC) was calculated and compared by the Chi-square test (alpha = .05). RESULTS: The interobserver agreement ranged from 0.5233 to 0.6034 for ULD-NORM, 0.5380 to 0.6279 for NORM, 0.5856 to 0.6300 for ULD-HR, and 0.6614 to 0.7707 for HR images. The intra-observer agreement ranged from 0.6027 to 0.8812 for ULD-HR, 0.7083 to 0.7556 for HR, 0.6076 to 0.9452 for ULD-NORM, and 0.7012 to 0.9221 for NORM images. Comparison of AUC revealed no significant difference between NORM and ULD-NORM (P > .05), or HR and ULD-HR (P > .05). The highest AUC belonged to HR (0.8529) and the lowest to NORM (0.7774). CONCLUSIONS: Considering the significant reduction in radiation dose in ULD CBCT and its acceptable diagnostic accuracy for detection of proximal caries, this protocol may be used for detection of proximal carious lesions and assessment of their depth.
Assuntos
Tomografia Computadorizada de Feixe Cônico , Cárie Dentária , Doses de Radiação , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Cárie Dentária/diagnóstico por imagem , Técnicas In Vitro , Dente Pré-Molar/diagnóstico por imagem , Dente Molar/diagnóstico por imagemRESUMO
OBJECTIVES: Nasotracheal intubation is a standard blind procedure associated with various complications. The selection of the appropriate nostril is crucial to preventing most of these complications. The present study aimed to evaluate the predictive ability of cone-beam CT (CBCT) images to select the correct nostril for nasotracheal intubation. METHODS: The study encompassed 60 patients who underwent maxillofacial surgery with nasotracheal intubation under general anaesthesia. While the anaesthetist made the appropriate nostril selection clinically according to a simple occlusion test and spatula test, the radiologist made the selection after analysing various CBCT findings such as the angle and direction of nasal septum deviation (NSD), minimum bone distance along the intubation path, and the presence of inferior turbinate hypertrophy. The appropriateness of these choices made blindly at different times was evaluated using descriptive statistics, chi-squared test, and independent samples t-test. RESULTS: The study found that 83.3% of the suggested nostril intubations were successful. We also observed that intubation duration was longer when inferior turbinate hypertrophy was present (P = .031). However, there was no statistical relationship between the presence of epistaxis and septal deviation (P = .395). Nonetheless, in 64.3% of cases with epistaxis, the intubated nostril and the septum deviation direction were the same. CONCLUSIONS: Pre-operative evaluations using CBCT can aid anaesthetists for septum deviation and turbinate hypertrophy, as both can impact intubation success rates and duration.
Assuntos
Tomografia Computadorizada de Feixe Cônico , Intubação Intratraqueal , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Intubação Intratraqueal/métodos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Adolescente , Cavidade Nasal/diagnóstico por imagem , Septo Nasal/diagnóstico por imagemRESUMO
OBJECTIVES: Preoperative diagnosis of oral ameloblastoma (AME) and odontogenic keratocyst (OKC) has been a challenge in dentistry. This study uses radiomics approaches and machine learning (ML) algorithms to characterize cone-beam CT (CBCT) image features for the preoperative differential diagnosis of AME and OKC and compares ML algorithms to expert radiologists to validate performance. METHODS: We retrospectively collected the data of 326 patients with AME and OKC, where all diagnoses were confirmed by histopathologic tests. A total of 348 features were selected to train six ML models for differential diagnosis by a 5-fold cross-validation. We then compared the performance of ML-based diagnoses to those of radiologists. RESULTS: Among the six ML models, XGBoost was effective in distinguishing AME and OKC in CBCT images, with its classification performance outperforming the other models. The mean precision, recall, accuracy, F1-score, and area under the curve (AUC) were 0.900, 0.807, 0.843, 0.841, and 0.872, respectively. Compared to the diagnostics by radiologists, ML-based radiomic diagnostics performed better. CONCLUSIONS: Radiomic-based ML algorithms allow CBCT images of AME and OKC to be distinguished accurately, facilitating the preoperative differential diagnosis of AME and OKC. ADVANCES IN KNOWLEDGE: ML and radiomic approaches with high-resolution CBCT images provide new insights into the differential diagnosis of AME and OKC.
Assuntos
Ameloblastoma , Tomografia Computadorizada de Feixe Cônico , Aprendizado de Máquina , Cistos Odontogênicos , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Ameloblastoma/diagnóstico por imagem , Ameloblastoma/cirurgia , Ameloblastoma/patologia , Cistos Odontogênicos/diagnóstico por imagem , Cistos Odontogênicos/cirurgia , Estudos Retrospectivos , Feminino , Masculino , Diagnóstico Diferencial , Adulto , Pessoa de Meia-Idade , Algoritmos , Adolescente , Idoso , Neoplasias Maxilomandibulares/diagnóstico por imagem , Neoplasias Maxilomandibulares/cirurgia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , RadiômicaRESUMO
OBJECTIVES: To determine the most distinctive quantitative radiomorphometric parameter(s) for the detection of MRONJ-affected bone changes in panoramic radiography (PR) and cone-beam CT (CBCT). METHODS: PR and sagittal CBCT slices of 24 MRONJ patients and 22 healthy controls were used for the measurements of mandibular cortical thickness (MCT), fractal dimension (FD), lacunarity, mean gray value (MGV), bone area fraction (BA/TA), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), trabecular number (Tb.N). MCT was measured in the mental foramen region. While FD and lacunarity were measured on mandibular trabecular and cortical regions-of-interest (ROIs), the remaining parameters were measured on trabecular ROIs. The independent samples t-test was used to compare the measurements between the MRONJ and control groups for both imaging modalities (P = .05). RESULTS: MCT was the only parameter that differentiated MRONJ-affected bone in both PR and CBCT (P < .05). None of the remaining parameters revealed any difference for MRONJ-affected bone in CBCT (P > .05). FD, lacunarity, MGV, BA/TA, and Tb.Sp could distinguish MRONJ-affected trabecular bone in PR (P < .05). The correspondent ROI for both imaging methods that was reliable for detecting MRONJ-affected bone was the trabecular bone distal to the mental foramen above the inferior alveolar canal (ROI-3). CONCLUSIONS: MCT is a reliable parameter for the discrimination of MRONJ-affected bone in both PR and CBCT images. PR may be used to detect MRONJ-affected trabecular bone using FD, lacunarity, MGV, BA/TA, and Tb.Sp measurements as well.