Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Protein Expr Purif ; 203: 106217, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36529448

RESUMO

For recombinantly produced monoclonal antibody (mAb), charge variants including acidic and basic species are common heterogeneities. For characterization purpose, sufficient amount of acidic and basic species with high purity is needed. In this work, we developed an approach that allows for continuous separating and collecting of acidic and basic charge variants. First, with batch-mode cation exchange (CEX) chromatography, the load density and linear salt gradient elution conditions under which good separation of both charge variants can be achieved were determined. Next, a stepwise elution protocol was developed based on the linear gradient elution. Finally, acidic and basic charge variants were persistently produced under stepwise elution using a customized twin-column continuous chromatography system. This approach allows acidic and basic charge variants with high purity (i.e., >90%) to be efficiently generated in sufficient amount, which greatly facilitates the necessary characterization of these mAb variants.


Assuntos
Anticorpos Monoclonais , Cloreto de Sódio , Cromatografia por Troca Iônica/métodos , Cloreto de Sódio/química , Anticorpos Monoclonais/química , Cátions/química
2.
Biotechnol Bioeng ; 119(8): 2152-2166, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35470430

RESUMO

In this study, we demonstrated the first, to our knowledge, integrated continuous bioprocess (ICB) designed for the production of acid-sensitive monoclonal antibodies, prone to aggregate at low pH, on pilot scale. A high cell density perfusion culture, stably maintained at 100 × 106 cells/ml, was integrated with the downstream process, consisting of a capture step with the recently developed Protein A ligand, ZCa ; a solvent/detergent-based virus inactivation; and two ion-exchange chromatography steps. The use of a mild pH in the downstream process makes this ICB suitable for the purification of acid-sensitive monoclonal antibodies. Integration and automation of the downstream process were achieved using the Orbit software, and the same equipment and control system were used in initial small-scale trials and the pilot-scale downstream process. High recovery yields of around 90% and a productivity close to 1 g purified antibody/L/day were achieved, with a stable glycosylation pattern and efficient removal of impurities, such as host cell proteins and DNA. Finally, negligible levels of antibody aggregates were detected owing to the mild conditions used throughout the process. The present work paves the way for future industrial-scale integrated continuous biomanufacturing of all types of antibodies, regardless of acid stability.


Assuntos
Anticorpos Monoclonais , Animais , Anticorpos Monoclonais/biossíntese , Anticorpos Monoclonais/química , Reatores Biológicos , Células CHO , Cricetinae , Cricetulus , Proteína Estafilocócica A/química
3.
Biotechnol Bioeng ; 118(9): 3420-3434, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33755192

RESUMO

The increasing demand for efficient and robust processes in the purification of monoclonal antibodies (mAbs) has recently brought frontal chromatography to the forefront. Applied during the polishing step, it enables the removal of high molecular weight aggregates from the target product, achieving high purities. Typically, this process is operated in batch using a single column, which makes it intrinsically subjected to a purity-yield tradeoff. This means that high purities can only be achieved at the cost of lowering the product yield and vice versa. Recently, a two-column continuous implementation of frontal chromatography, referred to as Flow2, was developed. Despite being able of alleviating the purity-yield tradeoff typical of batch operations, the increase in the number of process parameters complicates its optimal design, with the risk of not exploiting its full potential. In this study, we developed an ad hoc design procedure (DP) suitable for the optimization of both batch frontal chromatography and Flow2 in terms of purity, yield, and productivity. This procedure provided similar results as a multiobjective optimization based on genetic algorithm but with lower computational effort. Then, batch and Flow2 operated at their optimal conditions were compared. Besides showing a more favorable Pareto front of yield and productivity at a specified purity, the Flow2 process demonstrated improved robustness compared to the batch process with respect to modifications in the loading linear velocity, washing buffer ionic strength and loading time, thus providing an appealing operation for integrated processes.


Assuntos
Anticorpos Monoclonais , Proteína Estafilocócica A/química , Anticorpos Monoclonais/química , Anticorpos Monoclonais/isolamento & purificação , Cromatografia de Afinidade , Cromatografia por Troca Iônica
4.
Biotechnol Bioeng ; 118(9): 3313-3322, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33480439

RESUMO

Continuous capture with affinity chromatography is one of the most important units for continuous manufacturing of monoclonal antibody (mAb). Due to the complexity of three-column periodic counter-current chromatography (3C-PCC), three approaches (experimental, model-based, and simplified approaches) were studied for process development and optimization. The effects of residence time for interconnected load (RT C ), breakthrough percentage of the first column for interconnected load (s) and feed protein concentration (c 0 ) on productivity and capacity utilization were focused. The model-based approach was found superior to the experimental approach in process optimization and evaluation. Two phases of productivity were observed and the optimal RT C for the maximum productivity was located at the boundary of the two phases. The comprehensive effects of the operating parameters (RT C , s, and c 0 ) were evaluated by the model-based approach, and the operation space was predicted. The best performance of 34.5 g/L/h productivity and 97.6% capacity utilization were attained for MabSelect SuRe LX resin under 5 g/L concentration at RT C = 2.8 min and s = 87.5%. Moreover, a simplified approach was suggested to obtain the optimal RT C for the maximum productivity. The results demonstrated that model-assisted tools are useful to determine the optimum conditions for 3C-PCC continuous capture with high productivity and capacity utilization.


Assuntos
Anticorpos Monoclonais/química , Anticorpos Monoclonais/isolamento & purificação , Cromatografia de Afinidade , Distribuição Contracorrente
5.
Biotechnol Bioeng ; 118(1): 164-174, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32910459

RESUMO

An efficient and consistent method of monoclonal antibody (mAb) purification can improve process productivity and product consistency. Although protein A chromatography removes most host-cell proteins (HCPs), mAb aggregates and the remaining HCPs are challenging to remove in a typical bind-and-elute cation-exchange chromatography (CEX) polishing step. A variant of the bind-and-elute mode is the displacement mode, which allows strongly binding impurities to be preferentially retained and significantly improves resin utilization. Improved resin utilization renders displacement chromatography particularly suitable in continuous chromatography operations. In this study we demonstrate and exploit sample displacement between a mAb and impurities present at low prevalence (0.002%-1.4%) using different multicolumn designs and recycling. Aggregate displacement depends on the residence time, sample concentration, and solution environment, the latter by enhancing the differences between the binding affinities of the product and the impurities. Displacement among the mAb and low-prevalence HCPs resulted in an effectively bimodal-like distribution of HCPs along the length of a multi-column system, with the mAb separating the relatively more basic group of HCPs from those that are more acidic. Our findings demonstrate that displacement of low-prevalence impurities along multiple CEX columns allows for selective separation of mAb aggregates and HCPs that persist through protein A chromatography.


Assuntos
Anticorpos Monoclonais/isolamento & purificação , Cromatografia por Troca Iônica , Agregados Proteicos , Animais , Anticorpos Monoclonais/química , Células CHO , Cricetulus
6.
Biotechnol Bioeng ; 118(9): 3522-3532, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33818758

RESUMO

Virus-based biologicals are one of the most promising biopharmaceuticals of the 21st century medicine and play a significant role in the development of innovative therapeutic, prophylactic, and clinical applications. Oncolytic virus manufacturing scale can range from 5 L in research and development up to 50 L for clinical studies and reach hundreds of liters for commercial scale. The inherent productivity and high integration potential of periodic counter-current chromatography (PCC) offer a transversal solution to decrease equipment footprint and the reduction of several non-value-added unit operations. We report on the design of an efficient PCC process applied to the intermediate purification of oncolytic adenovirus. The developed ion-exchange chromatographic purification method was carried out using a four-column setup for three different scenarios: (i) variation in the feedstock, (ii) potential use of a post-load washing step to improve virus recovery, and (iii) stability during extended operation. Obtained virus recoveries (57%-86%) and impurity reductions (>80% DNA, and >70% total protein) match or overcome batch purification. Regarding process stability and automation, our results show that not only the dynamic control strategy used is able to suppress perturbations in the sample inlet but also allows for unattended operation in the case of ion exchange capture.


Assuntos
Produtos Biológicos/isolamento & purificação , Vírus Oncolíticos/isolamento & purificação , Células A549 , Distribuição Contracorrente , Humanos
7.
Biotechnol Bioeng ; 118(3): 1262-1272, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33283261

RESUMO

A new method was proposed for increasing the capture chromatography process efficiency, linear flow-velocity gradient (LFG). The method uses a linear decreasing flow-velocity gradient with time during the sample loading. The initial flow velocity, the final flow velocity and the gradient time are the parameters to be tuned. We have developed a method for determining these parameters by using the total column capacity and the total loaded amount as a function of time. The capacity can be calculated by using the relationships between dynamic binding capacity (DBC) and residence time. By leveraging the capacity, loading amount, and the required conditions, the optimum LFG can be designed. The method was verified by ion-exchange and protein A chromatography of monoclonal antibodies (mAbs). A two-fold increase in the productivity during the sample loading was possible by LFG compared with the constant flow-velocity (CF) operation. LFG was also applied to a 4-column continuous process. The simulation showed that the cost of resin per unit amount of processed mAbs can be reduced by 13% while 1.4 times enhancement in productivity was preserved after optimization by LFG compared to CF. The process efficiency improvement is more pronounced when the isotherm is highly favorable and the loading volume is large.


Assuntos
Anticorpos Monoclonais , Cromatografia de Afinidade , Simulação por Computador , Modelos Químicos , Proteína Estafilocócica A/química , Animais , Anticorpos Monoclonais/química , Anticorpos Monoclonais/isolamento & purificação
8.
Molecules ; 26(15)2021 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-34361839

RESUMO

The market of biomolecules with therapeutic scopes, including peptides, is continuously expanding. The interest towards this class of pharmaceuticals is stimulated by the broad range of bioactivities that peptides can trigger in the human body. The main production methods to obtain peptides are enzymatic hydrolysis, microbial fermentation, recombinant approach and, especially, chemical synthesis. None of these methods, however, produce exclusively the target product. Other species represent impurities that, for safety and pharmaceutical quality reasons, must be removed. The remarkable production volumes of peptide mixtures have generated a strong interest towards the purification procedures, particularly due to their relevant impact on the manufacturing costs. The purification method of choice is mainly preparative liquid chromatography, because of its flexibility, which allows one to choose case-by-case the experimental conditions that most suitably fit that particular purification problem. Different modes of chromatography that can cover almost every separation case are reviewed in this article. Additionally, an outlook to a very recent continuous chromatographic process (namely Multicolumn Countercurrent Solvent Gradient Purification, MCSGP) and future perspectives regarding purification strategies will be considered at the end of this review.


Assuntos
Peptídeos/química , Peptídeos/síntese química , Peptídeos/isolamento & purificação , Cromatografia Líquida , Humanos , Peptídeos/uso terapêutico
9.
Biotechnol Bioeng ; 117(3): 646-653, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31784975

RESUMO

Continuous countercurrent tangential chromatography (CCTC) enables steady-state continuous bioprocessing with low-pressure operation and high productivity. CCTC has been applied to initial capture of monoclonal antibodies (mAb) from clarified cell culture harvest and postcapture polishing of mAb; however, these studies were performed with commercial chromatography resins designed for conventional column chromatography. In this study, a small particle size prototype agarose resin (20-25 µm) with lower cross-linking was co-developed with industrial partner Purolite and tested with CCTC. Due to increased binding capacity and faster kinetics, the resulting CCTC process showed more than a 2X increase in productivity, and a 2X reduction in buffer consumption over commercial protein A resins used in previous CCTC studies, as well as more than a 10X productivity increase versus conventional column operation. Single-pass tangential flow filtration was integrated with the CCTC system, enabling simple control of eluate concentration. A scale-up exercise was conducted to provide a quantitative comparison of CCTC and batch column chromatography. These results clearly demonstrate opportunities for using otherwise unpackable soft small particle size resins with CCTC as the core of a continuous bioprocessing platform.


Assuntos
Anticorpos Monoclonais/isolamento & purificação , Reatores Biológicos , Distribuição Contracorrente/métodos , Proteína Estafilocócica A , Animais , Células CHO , Cricetinae , Cricetulus , Proteína Estafilocócica A/química , Proteína Estafilocócica A/metabolismo
10.
Biotechnol Bioeng ; 117(3): 673-686, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31788777

RESUMO

Control of column loading in Protein A chromatography is a crucial part of development of robust and flexible process platforms for continuous production of monoclonal antibody (mAb) products. In this paper, we propose a control system that uses near infrared spectroscopy (NIRS) flow cells to accomplish the above. Two applications have been demonstrated using a periodic counter-current continuous chromatography setup. The first application involves use of single NIR flow cell before the inlet of the loading column to measure the concentration of mAb in the harvested broth. Measurement was in real-time (every 3 s) and within ±0.05 mg/ml, significantly better than making UV-based concentration estimations. The second application involved use of an additional NIR flow cell at the outlet of the loading column to measure column breakthrough in real time. The concentration data was transferred to a Python-based monitoring and control algorithm layered over a Cadence BioSMB system. The program could successfully run a three-column periodic counter current method on the BioSMB whereas controlling loading to ensure optimal resin utilization in each loading cycle phase based on precharacterized dynamic binding capacity models, whereas maintaining periodic elutions. The system was tested with multiple perturbations in harvest concentration, modeled after deviations that could arise downstream of a perfusion cell culture system. The results show that the proposed control is a spectroscopy-based process analytical technology tool that facilitates real time monitoring and control of loading in process chromatography. It is adaptable to any continuous chromatography equipment and is very well suited for implementation in a continuous mAb production train.


Assuntos
Anticorpos Monoclonais , Cromatografia de Afinidade/métodos , Distribuição Contracorrente/métodos , Técnicas Fotoacústicas/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Animais , Anticorpos Monoclonais/química , Anticorpos Monoclonais/metabolismo , Reatores Biológicos , Células Cultivadas , Desenho de Equipamento , Proteína Estafilocócica A/química , Proteína Estafilocócica A/metabolismo
11.
Trends Analyt Chem ; 132: 116051, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32994652

RESUMO

Single-column (batch) preparative chromatography is the technique of choice for purification of biotherapeutics but it is often characterized by an intrinsic limitation in terms of yield-purity trade-off, especially for separations containing a larger number of product-related impurities. This drawback can be alleviated by employing multicolumn continuous chromatography. Among the different methods working in continuous mode, in this paper we will focus in particular on Multicolumn Countercurrent Solvent Gradient Purification (MCSGP) which has been specifically designed for challenging separations of target biomolecules from their product-related impurities. The improvements come from the automatic internal recycling of the impure fractions inside the chromatographic system, which results in an increased yield without compromising the purity of the pool. In this article, steps of the manufacturing process of biopharmaceuticals will be described, as well as the advantages of continuous chromatography over batch processes, by particularly focusing on MCSGP.

12.
Biotechnol Bioeng ; 116(9): 2275-2284, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31062872

RESUMO

Multicolumn capture chromatography is gaining increased attention lately due to the significant economic and process advantages it offers compared with traditional batch mode chromatography. However, for wide adoption of this technology in clinical and commercial space, it requires scalable models for executing viral validation studies. In this study, viral validation studies were conducted under cGLP guidelines to assess retro- (X-MuLV) and parvo-virus (MVM) clearance across twin-column continuous capture chromatography (CaptureSMB). A surrogate model was also developed using standard batch mode chromatography based on flow path modifications to mimic the loading strategy used in CaptureSMB. The results show that a steady state was achieved by the second cycle for both antibody binding and virus clearance and that the surrogate model using batch mode chromatography equipment provided impurity clearance that was comparable to that obtained during cyclical operation of CaptureSMB. Further, the log reduction values (LRVs) achieved during CaptureSMB were also comparable to the LRVs obtained using standard batch capture chromatography. This was expected since the mode of virus separation during protein A chromatography is primarily based on removal during the flow through and wash steps. Finally, this study also presents assessments on the resin cleaning strategy during continuous chromatography and how the duration of clean-in-place solution exposure impacts virus carryover.


Assuntos
Vírus da Leucemia Murina/química , Vírus Miúdo do Camundongo/química , Modelos Químicos , Inativação de Vírus , Cromatografia Líquida , Proteína Estafilocócica A/química
13.
Biotechnol Bioeng ; 116(9): 2292-2302, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31112283

RESUMO

Continuous bioprocessing holds the potential to improve product consistency, accelerate productivity, and lower cost of production. However, switching a bioprocess from traditional batch to continuous mode requires surmounting business and regulatory challenges. A key regulatory requirement for all biopharmaceuticals is virus safety, which is assured through a combination of testing and virus clearance through purification unit operations. For continuous processing, unit operations such as capture chromatography have aspects that could be impacted by a change to continuous multicolumn operation, for example, do they clear viruses as well as a traditional batch single column. In this study we evaluate how modifying chromatographic parameters including the linear velocity and resin capacity utilization could impact virus clearance in the context of moving from a single column to multicolumn operation. A Design of Experiment (DoE) approach was taken with two model monoclonal antibodies (mAbs) and two bacteriophages used as mammalian virus surrogates. The DoE enabled the identification of best and worst-case scenario for virus clearance overall. Using these best and worst-case conditions, virus clearance was tested in single column and multicolumn modes and found to be similar as measured by Log Reduction Values (LRV). The parameters identified as impactful for viral clearance in single column mode were predictive of multicolumn modes. Thus, these results support the hypothesis that the viral clearance capabilities of a multicolumn continuous Protein A system may be evaluated using an appropriately scaled-down single mode column and equipment.


Assuntos
Anticorpos Monoclonais/química , Anticorpos Monoclonais/isolamento & purificação , Modelos Químicos , Vírus/química , Cromatografia Líquida , Humanos
14.
Protein Expr Purif ; 159: 75-82, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30917921

RESUMO

The ability to engineer monoclonal antibodies (mAbs) with high specificity made mAbs the fastest growing segment in the drug market. mAbs represent 8 of the top 20 selling drugs with combined sales of more than 57 billion US$ per year. The ability to purify large numbers of mAbs with sufficient yields for initial screening campaigns has direct impact on the timelines of a project. Automated liquid handling (ALH)-based mAb purification platforms have been used to facilitate the production of large numbers of mAbs. However, the ongoing pressure to de-risk potential lead molecules at an early development stage by including bio-physical characterization of mAbs has further increased the demand to produce sufficient quantities from limited sample volumes. A bottleneck so far has been the limited dynamic binding capacity of these systems, which is partly due to the binding properties of commonly used Protein A affinity matrices. The present publication suggests that by using a Protein A matrix optimized for continuous chromatography applications the yields of ALH-based but also standard lab-scale mAb purifications can be significantly increased without the need to change established protocols.


Assuntos
Anticorpos Monoclonais/química , Proteínas Recombinantes de Fusão/química , Anticorpos Monoclonais/genética , Células Cultivadas , Cromatografia de Afinidade , Ensaios de Triagem em Larga Escala/métodos , Humanos , Proteínas Recombinantes de Fusão/genética , Robótica , Proteína Estafilocócica A/química , Transfecção
15.
Chirality ; 31(8): 583-591, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31185131

RESUMO

Praziquantel (PZQ) composes a regular medicine available in a tablet form to fight schistosomiasis and just half of its mass is composed by the active principle (L-PZQ), the other half, D-PZQ, is frequently associated to a strong bitter taste. Moreover, optically pure L-PZQ derivatives could be used in studies about adult and juvenile worms' resistance. Nowadays, these studies use racemic PZQ (rac-PZQ) as starting point. The D-PZQ, which would be discarded, could be racemized, coming back as feed concentration in the process. The present work aims to get L-PZQ and D-PZQ with high optical purities (more than 97%) and productivity (more than 253 g kgads -1  day-1 ) towards semipreparative scale for researches involving L-PZQ, L-PZQ derivatives, and D-PZQ racemization. In order to achieve this goal, a built-in-house simulated moving bed chromatographic unit with the cellulose tris (3-chloro-4-methylphenylcarbamate) (Chiralcel OZ) as chiral stationary phase (CSP) was used to investigate different scenarios of separation according to a well-known design method called triangle theory. In all scenarios investigated, at least one of the outlet streams presented high optically purity for one of the enantiomers. Comparison with literature showed superior performance of our unit even at racemic mixture concentrations that were 10 times lower than the racemic concentrations found in literature.

16.
Biotechnol Bioeng ; 115(12): 2893-2907, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30080940

RESUMO

Rapid advances in intensifying upstream processes for biologics production have left downstream processing as a bottleneck in the manufacturing scheme. Biomanufacturers are pursuing continuous downstream process development to increase efficiency and flexibility, reduce footprint and cost of goods, and improve product consistency and quality. Even after successful laboratory trials, the implementation of a continuous process at manufacturing scale is not easy to achieve. This paper reviews specific challenges in converting each downstream unit operation to a continuous mode. Key elements of developing practical strategies for overcoming these challenges are detailed. These include equipment valve complexity, favorable column aspect ratio, protein-A resin selection, quantitative assessment of chromatogram peak size and shape, holistic process characterization approach, and a customized process economic evaluation. Overall, this study provides a comprehensive review of current trends and the path forward for implementing continuous downstream processing at the manufacturing scale.


Assuntos
Anticorpos Monoclonais , Reatores Biológicos , Biotecnologia , Animais , Anticorpos Monoclonais/isolamento & purificação , Anticorpos Monoclonais/metabolismo , Biotecnologia/métodos , Biotecnologia/normas , Biotecnologia/tendências , Cromatografia , Humanos , Membranas Artificiais
17.
J Sep Sci ; 41(11): 2432-2440, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29577593

RESUMO

In this study, an effective method was developed for the isolation and enrichment of Ginkgo biloba extract by continuous chromatography system. The adsorption and desorption ratio of flavonoids as main index, the best macroporous resin was screened out from six resins by static adsorption and desorption tests. At the same time the adsorption and desorption parameters were optimized by dynamic adsorption and desorption tests. Under optimal parameters, five operations consisting of loading, washing, desorbing, regenerating, and balancing were integrated across the continuous chromatography system for the purpose of refining 66 L of crude extract solution. The results were as follows, 198.22 g of Ginkgo biloba extracts was produced, which contained 65.83 g of flavonoids and 15.44 g of lactones. The content of flavonoids and lactones increased from 2.76 and 0.72% in the crude extract to 33.21 and 7.79%, with a recovery yield of 91.26 and 81.21%. Methodology validation showed that the proposed method had high stability and reproducibility. Compared with the traditional macroporous resin method, the proposed method had a short processing time and low solvent consumption. Our studies indicated that the newly developed method is an effective procedure for the isolation and enrichment of Ginkgo biloba extract.


Assuntos
Cromatografia Líquida/métodos , Flavonoides/isolamento & purificação , Ginkgo biloba/química , Extratos Vegetais/isolamento & purificação , Adsorção , Cromatografia Líquida/instrumentação , Flavonoides/química , Extratos Vegetais/química
18.
Biotechnol Lett ; 40(6): 895-905, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29700726

RESUMO

Over the last several decades, researchers have time and again proposed use of non-chromatographic methods for processing of biotherapeutic products. However, chromatography continues to be the backbone of downstream processing, particularly at process scale. There are many reasons for this, critical ones being the unparalleled scalability, robustness, and selectivity that process chromatography offers over its peers. It is no surprise then that process chromatography has been a topic of major developments in resin matrix, ligand chemistry, modalities, high throughput process development, process modelling, and approaches for control. In this review, we attempt to summarize major developments in the above-mentioned areas. Greater significance has been given to advancements in the last 5 years (2013-2017).


Assuntos
Anticorpos Monoclonais/isolamento & purificação , Cromatografia , Proteínas Recombinantes/isolamento & purificação , Animais , Biofarmácia , Cromatografia/instrumentação , Cromatografia/métodos , Cromatografia/tendências , Humanos
19.
Prep Biochem Biotechnol ; 48(5): 383-390, 2018 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-29509101

RESUMO

A new integrated continuous biomanufacturing platform for continuous production of antibodies at fixed cell volumes and cell concentrations for extended periods with immediate capture is presented. Upstream antibody production has reached technological maturity, however, the bottleneck for continuous biomanufacturing remains the efficient and cost-effective capture of therapeutic antibodies in an initial chromatography step. In this study, the first successful attempt at using one-column continuous chromatography (OCC) for the continuous capture of therapeutic antibodies produced through alternating tangential flow perfusion is presented. By performing upstream media optimizations, the upstream perfusion rate was reduced to one vessel volume per day (vv/d), increasing antibody titer and reducing the volume of perfusate. In addition, process improvements were performed to increase productivity by 80% over previously reported values. In addition, a real-time method for evaluating column performance to make column switching decisions was developed. This improved productivity coupled with the use of a single-column improved process monitoring and control in OCC compared to multi-column systems. This approach is the first report on using a single column for the implementation of an integrated continuous biomanufacturing platform and offers a cost-effective and flexible platform process for the manufacture of therapeutic proteins.


Assuntos
Anticorpos Monoclonais/isolamento & purificação , Reatores Biológicos , Biotecnologia/instrumentação , Cromatografia/instrumentação , Animais , Reatores Biológicos/economia , Células CHO , Contagem de Células , Tamanho Celular , Cromatografia/economia , Cricetulus , Perfusão/economia , Perfusão/instrumentação , Resinas Sintéticas/química , Proteína Estafilocócica A/química
20.
Prep Biochem Biotechnol ; 45(8): 836-49, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25674930

RESUMO

The merits of continuous processing over batch processing are well known in the manufacturing industry. Continuous operation results in shorter process times due to omission of hold steps, higher productivity due to reduced shutdown costs, and lowers labor requirement. Over the past decade, there has been an increasing interest in continuous processing within the bioprocessing community, specifically those involved in production of biotherapeutics. Continuous operations in upstream processing (perfusion) have been performed for decades. However, recent development of continuous downstream operations has led the industry to envisage an integrated bioprocessing platform for efficient production. The regulators, key players in the biotherapeutic industry, have also expressed their interest and willingness in this migration from the traditional batch processing. This paper aims to review major developments in continuous bioprocessing in the past decade. A discussion of pros and cons of the different proposed approaches has also been presented.


Assuntos
Biotecnologia/métodos , Biotecnologia/normas , Indústria Farmacêutica/métodos , Indústria Farmacêutica/normas
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa