Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Med ; 11(19)2022 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-36233673

RESUMO

Osteoid osteoma is a benign bone tumor typically affecting the long bones of the lower limbs in young male patients. The lesion can be asymptomatic but, in most cases, patients present with characteristic nocturnal pain that is very responsive to the administration of non-steroidal anti-inflammatory drugs. Although osteoid osteomas can regress spontaneously over time, surgical therapy is often indicated in cases of long-lasting resistant pain. Apart from a traditional open resection, the modalities of minimally invasive surgery, such as radiofrequency ablation or cryoablation, have gradually become the option of choice in most cases. The first part of this manuscript is a minireview of the contemporary literature on the pathogenesis, diagnosis, and current trends in the treatment of osteoid osteoma. The second part is a case report of our own experience with a conventional C-arm-guided radiofrequency ablation of an osteoid osteoma located in the femoral neck in an adolescent patient. The aim was to prove that, even when more sophisticated guiding devices (CT, O-arm, etc.) are not available, the safe and reliable ablation of the lesion using a C-arm is still possible even in hard-to-reach areas. The case was a success, with no perioperative or postoperative complications.

2.
J Hand Surg Eur Vol ; 41(3): 340-5, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26115681

RESUMO

This study was performed to measure the equivalent scattered radiation dose delivered to susceptible organs while simulating orthopaedic surgery using conventional and mini C-arm fluoroscopy. In addition, shielding effects on the thyroid, thymus, and gonad, and the direct exposure delivered to the patient's hands were also compared. A conventional and mini C-arms were installed in an operating room, and a hand and an operator phantom were used to simulate a patient's hand and a surgeon. Photoluminescence dosimeters were used to measure the equivalent dose by scattered radiation arriving at the thyroid, thymus, and gonad on a whole-body phantom in the position of the surgeon. Equivalent scattered radiation doses were measured in four groups: (1) unshielded conventional C-arm group; (2) unshielded mini C-arm group; (3) lead-shielded conventional C-arm group; and (4) lead-shielded mini C-arm group. Equivalent scattered radiation doses to the unshielded group were significantly lower in the mini C-arm group than those in the conventional C-arm group for all organs. The gonad in the lead-shielded conventional C-arm group showed the highest equivalent dose among operator-susceptible organs, and radiation dose was reduced by approximately 96% compared with that in the unshielded group. Scattered radiation was not detected in any susceptible organ in the lead-shielded mini C-arm group. The direct radiation dose to the hand phantom measured from the mini C-arm was significantly lower than that measured from the conventional C-arm. The results show that the equivalent scattered radiation dose to the surgeon's susceptible organs and the direct radiation dose to a patient's hand can be decreased significantly by using a mini C-arm rather than a conventional C-arm. However, protective lead garments, such as a thyroid shield and apron, should be applied to minimize radiation exposure to susceptible organs, even during use of mini C-arm fluoroscopy.


Assuntos
Fluoroscopia/instrumentação , Exposição Ocupacional , Ortopedia , Doses de Radiação , Exposição à Radiação , Radiação Ionizante , Gônadas , Humanos , Imagens de Fantasmas , Timo , Glândula Tireoide
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa