Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
BMC Oral Health ; 24(1): 206, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38336698

RESUMO

BACKGROUND: The various physical and chemical conditions within the oral cavity are hypothesized to have a significant influence on the behavior of denture adhesives and therefore the overall comfort of denture wearers. As such, this study aims to understand the influence of oral cavity physiological parameters such as temperature (17 to 52 °C), pH (2, 7, 10), and denture adhesive swelling due to saliva (20-120%) on the behavior of denture adhesives. This study further aims to emphasize the need for a collective approach to modelling the in-situ behavior of denture adhesives. METHODS: Rheological measurements were carried out using the Super Polygrip Ultra fresh brand denture adhesive cream to evaluate its storage modulus (G´) and loss modulus (G´´) values at a range of physiologically relevant temperatures, pH values, and degrees of swelling, to represent and characterize the wide variety of conditions that occur within the oral cavity. RESULTS: Rheological data was recorded with respect to variation of temperature, pH, and swelling. Overall, it can be seen that the physiological conditions of the oral cavity have an influence on the rheological properties of the denture adhesive cream. Specifically, our data indicates that the adhesive's mechanical properties are weakly influenced by pH, but do change with respect to the temperature in the oral cavity and the swelling rate of the adhesive. CONCLUSIONS: Our results suggest that the collective inter-play of the parameters pH, temperature and swelling ratio have an influence on the behavior of the denture adhesive. The results clearly highlight the need for developing a multi-parameter viscoelastic material model to understand the collective influence of physiological parameters on the performance of denture adhesives. Multi-parameter models can also potentially be utilized in numerically simulating denture adhesives using finite element simulations.


Assuntos
Cimentos Dentários , Retenção de Dentadura , Humanos , Cimentos Dentários/química , Temperatura , Boca , Concentração de Íons de Hidrogênio
2.
J Prosthodont ; 33(4): 324-329, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37805705

RESUMO

PURPOSE: To compare the effects of two denture adhesive formulations on the bite force required to dislodge a maxillary denture in adult participants during a 13-h test period. MATERIALS AND METHODS: Twenty-two participants with a fair-to-poor fitting maxillary denture opposed by natural dentition or a stable mandibular denture were enrolled in this single-center, randomized, double-blind, two-treatment, 4-period crossover study. Participants were randomly assigned a product usage sequence so that each participant used each product twice during the 4-day test period. The test product was a denture cream adhesive formulated with an optimized calcium/zinc partial salt of polyvinyl methyl ether/maleic acid (Fixodent Ultra technology); the control product was a cream adhesive formulated with a calcium/zinc partial salt of polyvinyl methyl ether/maleic acid (Fixodent Original technology). On each study day, bite force at dislodgement was measured with a gnathodynamometer at baseline, representing the "no adhesive" score. Then, after standardized product application to the participant's existing maxillary denture by site staff, bite force measurements were retaken at 1, 3, 5, 7, 9, 11, and 13 h. The change from baseline and the 13-h area under the bite-force-change-from-baseline curve were analyzed via an analysis of variance. RESULTS: Twenty-one participants completed all test periods; one additional participant completed three test periods so 22 participants were included in the analysis. There were 15 females and 7 males with a mean age of 70 years. The mean 13-h area under the bite-force-change-from-baseline curve was 8% greater (p = 0.010) for the test adhesive (114.3 lb) than for the control adhesive (105.9 lb). Both adhesives showed a statistically significant increase in bite force (p < 0.001) at each time point compared to no adhesive. CONCLUSIONS: The optimized calcium/zinc partial salt of polyvinyl methyl ether/maleic acid test adhesive provided superior maxillary denture retention relative to that of the control adhesive across 13 h. Both adhesives increased bite force at dislodgement compared to no adhesive.


Assuntos
Cimentos Dentários , Maleatos , Éteres Metílicos , Idoso , Feminino , Humanos , Masculino , Adesivos/uso terapêutico , Cálcio , Estudos Cross-Over , Retenção de Dentadura , Prótese Total , Polivinil , Zinco , Método Duplo-Cego
3.
BMC Oral Health ; 23(1): 1027, 2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-38114958

RESUMO

BACKGROUND: Denture adhesives can be useful in improving patients' satisfaction with complete dentures. However, comparison clinical trials are lacking. The purpose of this randomized clinical trial was to assess the satisfaction of edentulous patients and their oral health impact profile when provided with 3 types of denture adhesives. METHODS: Sixty-four completely edentulous patients seeking complete dentures for their first time were randomly divided into 3 groups. Each group received a set of complete dentures, which were adjusted at review appointments until participants reported no complaints. After 1 month of using the dentures, participants rated their overall satisfaction and their satisfaction regarding comfort, retention, stability, and efficiency of mastication and speech on a 100-mm visual analog scale (VAS). Participants also filled out the oral health impact profile for edentulous patients (OHIP-EDENT) questionnaire. Each group was then given 1 type of denture adhesive to use. Group C received Corega Ultra denture fixative cream (GlaxoSmithKline), Group O received Olivafix (Bonyf), and Group S received Sea. Bond adhesive strips (Sea.Bond). Mann-Whitney U test was used to analyze the differences in VAS scores before and after using the adhesive within each group and Wilcoxon-signed rank test was used to compare OHIP scores and total OHIP values before and after using the adhesive within each group (p = 0.05). Furthermore, Kruskal Wallis test was used to compare the differences before and after using the adhesives in VAS and OHIP values between the 3 groups. RESULTS: Significantly higher VAS values were detected in all groups and significantly lower values for many OHIP items in addition to total OHIP values were detected in all groups after using the adhesives (P < 0.05), except for the ease of cleaning for Group O and Group S (P > 0.05). No significant differences were found in VAS and OHIP values between the 3 groups (P > 0.05), except for the ease of cleaning which was significantly different between Group C and Group S (p = 0.005). CONCLUSIONS: Using denture adhesives for completely edentulous patients resulted in higher patient satisfaction as indicated by higher VAS scores as well as improved quality of life as indicated by lower OHIP-EDENT scores after using the adhesives. These improvements were not dependent on the type of adhesive, except for ease of cleaning as adhesive strips were easier to clean than paste type adhesives. TRIAL REGISTRATION: This trial was registered at ClinicalTrials.gov (ID: NCT05496283) on 11/08/2022.


Assuntos
Boca Edêntula , Satisfação do Paciente , Humanos , Qualidade de Vida , Cimentos Dentários , Retenção de Dentadura , Prótese Total
4.
BMC Oral Health ; 23(1): 344, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-37259078

RESUMO

BACKGROUND: A denture adhesive for dry mouth with good cleaning properties has recently been developed. While previous studies on models have shown the effectiveness of denture adhesives in terms of retention and cleanability, no reports have evaluated their effectiveness in the oral cavity. The aim of this study was to compare and investigate the retention and usability of an experimental palatal plate in the dentulous jaw using a denture adhesive for dry mouth, a conventional cream-type denture adhesive, an oral moisturizer, and a denture moisturizer. METHODS: Ten healthy dentulous participants (mean age 27.2 ± 1.6 years) were included in the study. Palatal plates were fabricated. Four test samples were used: denture adhesive for dry mouth, conventional denture adhesive (cream type), oral moisturizer, and denture moisturizer. The sample was applied to the inner surface of the palatal plates, and the retentive force of the palatal plate was measured every 10 min for 30 min. After the measurements, the study participants were asked to rinse the palatal plate with water and subjectively evaluate the samples used. RESULTS: The conventional denture adhesive (cream type) showed increased retentive force over time, with the maximum retentive force obtained after 10 min of application. However, its washability was rated second lowest. The denture adhesive for dry mouth showed the highest retentive force immediately after application. Its washability was also good. CONCLUSIONS: The results suggest that the denture adhesive for dry mouth has reasonable retentive force in the oral cavity and cleaning properties compared to the conventional cream-type denture adhesive.


Assuntos
Cimentos Dentários , Xerostomia , Adulto , Humanos , Retenção de Dentadura , Prótese Total
5.
BMC Oral Health ; 22(1): 289, 2022 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-35842648

RESUMO

BACKGROUND: Recently, a denture adhesive that is easy to clean and contain moisturizing ingredients have been developed for patients with dry mouth. Although the retentive force produced by conventional denture adhesives and oral moisturizers have been compared on models, no study has reported their comparison in the oral cavity. In this study, we aimed to clarify the effects of different directions of traction and loads at the time of pressure contact on the retentive force on a palatal plate made from a dentulous jaw model. METHODS: A palatal plate was fabricated with thermoplastic resin on a dentulous jaw model, and a loop-shaped traction device was attached to the centre of the palate. The test samples were a cream-type denture adhesive, a denture adhesive for dry mouth, an oral moisturizer, and a denture moisturizer. The specimens were applied to the inner surface of the plate, which was then mounted under vertical pressure. Then, the retentive force was measured, using a digital force gauge, while the plate was pulled in different directions and with different loads. RESULTS: No significant difference in retentive force was observed in any of the test samples when the direction of traction was between 45° and 60°. The retentive force of the denture adhesive for dry mouth was significantly higher with a direction of traction of 90° than that of 45° or 60°. The retentive force when oral moisturizer was used was significantly higher in the 90° traction direction than in the 45° direction. There was no significant difference between a force of 4.0 kgf or 5.5 kgf when using a denture adhesive for dry mouth. Comparing the four load size conditions, the larger the load, the higher was the retentive force. Similar results were obtained for the cream-type denture adhesive and denture moisturizer. Significantly higher retentive force was observed for larger loads when oral moisturizer was used. CONCLUSIONS: The results suggest that the direction of traction and the pressure load affect the retentive force on a palatal plate.


Assuntos
Retenção de Dentadura , Xerostomia , Cimentos Dentários , Humanos , Palato , Tração
6.
J Prosthodont ; 28(1): e252-e258, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29136307

RESUMO

PURPOSE: To study the effects of denture adhesive upon denture micromovements in three dimensions during the chewing of hard, sticky, and tough food items observed using a novel method involving an electromagnetic articulograph (EMA) speech research system. MATERIALS AND METHODS: Ten volunteers (mean age 60.9 ± 10.4 years) with fair- or poor-fitting complete maxillary dentures were enrolled. Chewing experiments were conducted using two treatments (adhesive or no-adhesive control) and three foods: carrots (hard), raisins (sticky), and processed meat stick (tough). Denture micromovement was measured through a novel application of a Northern Digital Wave EMA System. Three-dimensional denture position was captured during mastication using three sensors embedded into a replica denture for each subject. Following individual characterization of a "home" reference position, the Euclidean Distances from Home (DfH) were calculated for each recorded sample of the chewing experiments. The DfH at each sample represented the denture movement for that 1/100th of a second of the activity. The DfH data were then summarized as the mean DfH, the maximum DfH, and total distance traveled by the denture. Several thresholds were also analyzed, including the percent of time that the DfH ≥1.5 mm, ≥2.0 mm, and ≥2.5 mm. RESULTS: With adhesive treatment, the mean DfH of dentures during chewing was reduced by 26.8% for carrot, 30.3% for raisin, and 31.0% for meat stick, when compared with no-adhesive treatment (p < 0.001 for all comparisons). Similar results were also seen for the maximum DfH and total distance travelled endpoints across foods. For the threshold endpoints, adhesive treatment was associated with a statistically significant reduction in denture micromovements at all three thresholds across foods. At the threshold of DfH ≥ 1.5 mm, adhesive treatment was associated with a reduction in micromovement by 61.6%, 56.2%, and 70.0% with carrot, raisin, and meat stick, respectively (p ≤ 0.004 for all comparisons). CONCLUSIONS: Observations of denture movement using the Wave EMA System were able to differentiate systematically between adhesive treatment and no-adhesive treatment for denture micromovements during different chewing challenges. Use of adhesive was associated with statistically significant reductions in denture micromovements for hard, sticky, and tough foods as measured with both distance and threshold endpoints.


Assuntos
Articuladores Dentários , Cimentos Dentários/química , Fenômenos Eletromagnéticos , Mastigação/fisiologia , Resinas Acrílicas , Idoso , Planejamento de Dentadura , Retenção de Dentadura , Prótese Total Superior , Feminino , Alimentos , Preferências Alimentares , Humanos , Masculino , Maxila , Pessoa de Meia-Idade , Movimento/fisiologia
7.
J Prosthodont ; 27(8): 755-762, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27870138

RESUMO

PURPOSE: Several complications may arise in patients wearing complete prosthetic appliances, including denture-associated infections and mucosal stomatitis due to Candida species. This study evaluated the activity of anti-Candida agents in denture adhesive and the cytotoxicities of these preparations for primary human gingival epithelial (GE) keratinocytes. MATERIALS AND METHODS: The anti-Candida activities of antimicrobial peptides, antimicrobial lipids, and antifungal agents against C. albicans ATCC 64124 or HMV4C were assessed in microdilution assays containing water or 1% denture adhesive. The minimal inhibitory concentrations (MIC) and the minimal bactericidal concentrations (MBC) were determined. The cytotoxicities of denture adhesive compounded with these agents were assessed in 1.0 × 105 primary GE keratinocytes in LGM-3 media with resazurin. RESULTS: Lactoferricin B, SMAP28, sphingosine, dihydrosphingosine, and phytosphingosine in 1% denture adhesive lost antimicrobial activity for C. albicans (p < 0.05). Amphotericin B, chlorhexidine dihydrochloride, chlorhexidine gluconate, fluconazole, and nystatin in 1% denture adhesive or compounded directly into denture adhesive and then diluted to 1% adhesive, did not lose antimicrobial activity. Compounded formulations were not cytotoxic (LD50 > 100.0 µg/ml) against primary human GE keratinocytes. CONCLUSIONS: Antimicrobial peptides and antimicrobial lipids had diminished activities in 1% adhesive, suggesting that components in adhesives may inactivate local innate immune factors in the oral cavity, possibly predisposing denture wearers to Candida species infections. More importantly, antifungal agents retained their anti-C. albicans activities in denture adhesive, strongly suggesting that antifungal agents could be candidates for inclusion in adhesive formulations and used as prescribed topical treatments for individuals with denture stomatitis.


Assuntos
Adesivos/uso terapêutico , Antifúngicos/uso terapêutico , Candidíase Bucal/prevenção & controle , Retenção de Dentadura/métodos , Adesivos/administração & dosagem , Antifúngicos/administração & dosagem , Antifúngicos/efeitos adversos , Candida albicans/efeitos dos fármacos , Gengiva/efeitos dos fármacos , Humanos , Testes de Sensibilidade Microbiana
8.
J Contemp Dent Pract ; 19(8): 943-948, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30150494

RESUMO

AIM: The purpose of this in vitro study is to compare the bond strength to denture acrylics efficacy of miconazole gel against two denture adhesives with improved retentive properties (zinc-free PoliGrip cream and Snug denture soft cushion). MATERIALS AND METHODS: Eight heat-cured acrylic samples were prepared measuring 0.7 cm × 1.4 cm flat tested surface. The two well-adapted tested surfaces were matched and fixed to Universal Testing Machine clamp. Vertical separating load was applied at a rate of 1 mm/min to yield the maximum load before denture adhesive failure occurs. These measurements were used to express the retention bond strength when improved denture adhesive material was applied alone in comparison with micon-azole nitrate gel. Results were analyzed using one-way analysis of variance (ANOVA) statistical analysis at p-value of < 0.05. RESULTS: There was a statistically significant reduction in the mean tensile strength when the antifungal gel was opposed by the zinc-free PoliGrip cream. However, such a significant difference was not evident when the Snug denture cushion was opposed by the miconazole gel. CONCLUSION: The addition of antifungal gel to denture adhesives reduces retentive bond strength of denture adhesives to denture acrylics. However, if an antifungal gel has to be used, then a denture adhesive cushion soft plastic liner may provide a better retentive option than denture adhesive cream. CLINICAL SIGNIFICANCE: The incorporation of an antifungal agent into denture adhesives is required in many denture patients to suppress fugal growth and eliminate the undesirable health effects associated with such infections.


Assuntos
Adesivos , Antifúngicos , Colagem Dentária , Bases de Dentadura , Retenção de Dentadura/métodos , Miconazol , Resistência à Tração , Resinas Acrílicas , Reembasadores de Dentadura , Géis , Técnicas In Vitro
9.
Gerodontology ; 33(4): 453-460, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25643746

RESUMO

OBJECTIVE: We developed a new scoring index for assessing the removability of denture adhesives and evaluated the removal efficiency of denture cleaners. BACKGROUND: Although our understanding of the importance of denture care is increasing, little is known about the effectiveness and efficiency of denture cleaners on denture adhesives. Therefore, guidelines for proper cleaning are necessary. MATERIALS AND METHODS: We used five denture cleaner solutions on two cream adhesives, one powder adhesive and one cushion adhesive. After immersion in the denture cleaners for a designated time, we evaluated the area of the sample plate still covered by denture adhesive. RESULTS: Cream adhesives were removed more completely after immersion in majority of the denture cleaners than in water. Powder adhesive was removed more quickly than cream adhesives. Cushion adhesive was not removed by immersion in either the denture cleaners or water control. CONCLUSION: Some denture cleaners could liquefy cream adhesives more than water, but these differences were not observed in case of powder and cushion adhesives.


Assuntos
Adesivos/química , Higienizadores de Dentadura/normas , Dentaduras , Adesivos/classificação , Retenção de Dentadura , Humanos , Água
10.
Acta Odontol Scand ; 73(2): 87-92, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25220520

RESUMO

OBJECTIVE: The purpose of this study was to compare the cytotoxicity of four denture adhesives on human gingival fibroblast cells. MATERIALS AND METHODS: Immortalized human gingival fibroblasts were cultured with one of four different denture adhesives, Polident, Protefix, Staydent or Denfix-A, which was placed in insert dishes (10% w/v concentration) for 48 h. The MTT [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide] assay and flow cytometric apoptosis assay were used to evaluate cell viability and apoptosis rates. The fibroblasts were also examined under a scanning electron microscope. RESULTS: The MTT assay showed that all denture adhesives resulted in a significantly lower cell viability compared to the control cells propagated in normal culture medium (p < 0.05), with Staydent demonstrating the lowest cell viability. According to the flow cytometric apoptosis assay, Staydent and Protefix showed significantly higher apoptosis rates than the control group (p < 0.05), whereas Polident and Denfix-A did not demonstrate any significant differences (p > 0.05). Staydent showed the highest apoptosis rate. Scanning electron microscopy showed that the cells of the Staydent group underwent cytoplasmic membrane shrinkage, with cell free areas containing residual fragments of the membrane of dead cells. CONCLUSIONS: The four denture adhesives evaluated in this study imparted cytotoxic effects on human gingival fibroblast cells. Staydent showed the highest toxicity.


Assuntos
Adesivos/toxicidade , Retenção de Dentadura , Fibroblastos/efeitos dos fármacos , Gengiva/citologia , Apoptose/efeitos dos fármacos , Técnicas de Cultura de Células , Linhagem Celular , Membrana Celular/efeitos dos fármacos , Forma Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Citometria de Fluxo , Gengiva/efeitos dos fármacos , Humanos , Maleatos/toxicidade , Microscopia Eletrônica de Varredura , Polietilenos/toxicidade , Sais de Tetrazólio , Tiazóis , Fatores de Tempo
11.
J Prosthodont ; 24(5): 373-80, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25273800

RESUMO

PURPOSE: The purpose of this study was to assess differences of the Oral Health Implant Profile-14 (OHIP-14) scale over a month and determine association with gender, supporting tissues (KIS), and denture base (KID) among patients wearing complete dentures using denture adhesives. MATERIALS AND METHODS: Sixteen denture wearers, candidates for a new set of complete dentures, were selected. OHIP-14 scores were recorded at the beginning of the study, 6 weeks after fitting of the new set (T0 ), 15 days (T1 ), and finally 30 days (T2 ) after daily use of a denture adhesive as instructed. The KIS and KID were clinically examined and rated according to the Kapur Index. Statistical analyses were based on repeated-measures ANOVA, Mann-Whitney test, regression analysis, and Friedman test at a = 0.05. RESULTS: The OHIP-14 scale was found to have a high reliability (alpha = 0.847) and a high test-retest consistency (ICC = 0.889); however, domain 1 had the lowest item-total correlation (rho = 0.144) and item 7 a negative one (rho = -0.414). Trend analysis indicated a significant negative linear trend over time (slope = -3.156, p = 0.002), while repeated-measures ANOVA showed differences in OHIP-14 between T2 and T1 (p = 0.003) or T0 (p = 0.005) intervals. OHIP-14 groups were found to be positively associated with KIS (p = 0.010) and negatively with KID (p = 0.047) groups, but not with gender (p = 0.272). CONCLUSIONS: The study shows that OHIP-14 has a high internal reliability and consistency when applied to new denture wearers, and its score decreases if denture adhesives are used for at least 15 days. Low KIS and high KID contributes to this trend. Some OHIP-14 items are more associated than others with the total score trend over time.


Assuntos
Cimentos Dentários , Prótese Total , Saúde Bucal , Qualidade de Vida , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Inquéritos e Questionários
12.
Acta Odontol Scand ; 72(8): 839-45, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24791610

RESUMO

OBJECTIVE: To examine the initial viscosity and adhesive strength of modern denture adhesives in vitro. MATERIALS AND METHODS: Three cream-type denture adhesives (Poligrip S, Corect Cream, Liodent Cream; PGS, CRC, LDC) and three powder-type denture adhesives (Poligrip Powder, New Faston, Zanfton; PGP, FSN, ZFN) were used in this study. The initial viscosity was measured using a controlled-stress rheometer. The adhesive strength was measured according to ISO-10873 recommended procedures. All data were analyzed independently by one-way analysis of variance combined with a Student-Newman-Keuls multiple comparison test at a 5% level of significance. RESULTS: The initial viscosity of all the cream-type denture adhesives was lower than the powder-type adhesives. Before immersion in water, all the powder-type adhesives exhibited higher adhesive strength than the cream-type adhesives. However, the adhesive strength of cream-type denture adhesives increased significantly and exceeded the powder-type denture adhesives after immersion in water. For powder-type adhesives, the adhesive strength significantly decreased after immersion in water for 60 min, while the adhesive strength of the cream-type adhesives significantly decreased after immersion in water for 180 min. CONCLUSION: Cream-type denture adhesives have lower initial viscosity and higher adhesive strength than powder type adhesives, which may offer better manipulation properties and greater efficacy during application.


Assuntos
Adesivos/química , Retenção de Dentadura , Adesividade , Humanos , Imersão , Teste de Materiais , Pomadas/química , Pós/química , Reologia/instrumentação , Estresse Mecânico , Propriedades de Superfície , Temperatura , Viscosidade , Água/química
13.
Gerodontology ; 31(1): 4-10, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22612905

RESUMO

BACKGROUND: To date, there have been very little data on the cytotoxic responses of different cell lines to denture adhesives. OBJECTIVE: To determine the cytotoxicity of three denture adhesives on primary human oral keratinocytes (HOKs), fibroblasts (HOFs) and permanent mouse fibroblasts cell lines (L929). METHODS: Three commercial denture adhesives (two creams and one powder) were prepared for indirect contact using the agar diffusion test, as well as extracts in MTT assay. The results of the MTT assay were statistically analysed by one-way anova and Tukey's test (p < 0.05). RESULTS: All of the tested denture adhesives showed mild to moderate cytotoxicity to primary HOKs (p < 0.001), whereas none of three was toxic to L929 cells (p > 0.05) in both assays. For primary HOFs cultures, slight cytotoxicity was observed for one of the products from the agar diffusion test and undiluted eluates of all tested adhesives with MTT assay (p < 0.01). CONCLUSION: Denture adhesives are toxic to the primary HOKs and HOFs cultures, whereas non-toxic to L929 cells. The results suggest that primary human oral mucosal cells may provide more valuable information in toxicity screening of denture adhesives.


Assuntos
Adesivos/toxicidade , Retenção de Dentadura , Fibroblastos/efeitos dos fármacos , Gengiva/citologia , Queratinócitos/efeitos dos fármacos , Mucosa Bucal/citologia , Alginatos/toxicidade , Animais , Carboximetilcelulose Sódica/toxicidade , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Corantes , Gengiva/efeitos dos fármacos , Ácido Glucurônico/toxicidade , Ácidos Hexurônicos/toxicidade , Humanos , Maleatos/toxicidade , Camundongos , Mucosa Bucal/efeitos dos fármacos , Polietilenos/toxicidade , Sais de Tetrazólio , Tiazóis
14.
J Indian Prosthodont Soc ; 14(3): 243-50, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25183908

RESUMO

The use of denture adhesives (DA) and their role in prosthodontics has been a conflicted topic both in clinical practice and dental education. The use of adhesives, are viewed as poor reflection of their clinical skills and prosthetic expertise or to provide retention to an ill-fitting prosthesis by many dentists. These conflicting views have raised many doubts among practicising dentists on the use of DAs in their clinical practice. The aim of this study was to assess the knowledge, attitudes and practices of DA use among private dental practitioners' of Jabalpur city, Madhya Pradesh. This descriptive, cross-sectional survey was conducted using a self-administered questionnaire involving private dental practitioners of Jabalpur city. A total of 172 private dental practitioners of Jabalpur made up the sample of the study. A comprehensive, closed-ended, self-administered questionnaire was employed which was designed to collect the sociodemographic details and to assess the knowledge, attitudes and practices of DA use among private dental practitioners'. The institutional review committee approved the study. Data were imported to the SPSS 13.01 program to draw the means and percentages. Majority of the dentists were males (55 %), preponderance (68 %) of the dentists were in the 21-30 years age-group. Greater part of the study population comprised of general dental practitioners (GDPs) (81 %). When the subjects were questioned if DA were soluble in saliva, 32 % of the GDPs replied wrongly. Similarly 25 % of the GDPs didn't know that using DA with incompletely removed old DA affected tissue health. Zinc containing DA are recently held responsible for causing neurological diseases on their prolonged usage, 71 % of the GDPs and 74 % of other specialists were unaware in this context. A total of 115 (83 %) GDPs, 6 (100 %) prosthodontists and 22 (81 %) other specialist's used DA as a beneficial adjunct in their clinical practice. DA being used frequently by the dentists, unfortunately they did not have sufficient knowledge regarding the material. The attitude is a reflection of an individual's knowledge, which was also not homogeneous. By pursuing continuing education courses, the practitioners can update themselves regarding new technology and materials, thus improving the standard of care for prosthodontic patients.

15.
Future Microbiol ; 19(8): 655-665, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38700286

RESUMO

Aim: To evaluate the biological and mechanical properties of an adhesive with nanostructured silver vanadate (AgVO3). Materials & methods: Specimens in poly(methyl methacrylate) (PMMA) were treated with Ultra Corega Cream (UCCA) denture adhesive with or without AgVO3. Biofilms of Candida albicans, Candida glabrata and Streptococcus mutans were grown and the viable cells counted. Fluorescence microscopy was used. The viability of the VERO cell and adhesive strength were evaluated. Results: All concentrations of AgVO3 reduced the biofilm formation and showed no cytotoxic effect. At 5 min and 24 h, UCCA with 5 and 10% AgVO3 showed better performance, respectively. Conclusion: AgVO3 promoted the antibiofilm activity of the adhesive, with a positive effect on the adhesive strength, and was biocompatible.


What is this summary about? Some people wear false teeth called dentures. They use a special glue to keep these false teeth in their mouths. It is important to clean dentures well and remove the glue every day. If the dentures get dirty, they can cause infections of the gums. Doctors and dentists can help, but sometimes medicines do not work well. This study checked to see whether adding a medicine that can kill bacteria into the glue could stop gum swelling and other illnesses, or make them better.What were the results? The glue containing the medicine killed microbes like fungi and bacteria. It also stuck things together well and was safe to use.What do the results mean? Using this special glue could help people with dentures to avoid illness.


Assuntos
Biofilmes , Streptococcus mutans , Vanadatos , Biofilmes/efeitos dos fármacos , Vanadatos/farmacologia , Animais , Células Vero , Chlorocebus aethiops , Streptococcus mutans/efeitos dos fármacos , Materiais Biocompatíveis/farmacologia , Candida albicans/efeitos dos fármacos , Candida albicans/fisiologia , Prata/farmacologia , Prata/química , Dentaduras/microbiologia , Teste de Materiais , Polimetil Metacrilato/química , Cimentos Dentários/farmacologia , Cimentos Dentários/química , Aderência Bacteriana/efeitos dos fármacos , Adesivos/farmacologia , Adesivos/química
16.
J Prosthodont Res ; 68(1): 132-138, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-37316261

RESUMO

PURPOSE: The purpose of this study is to investigate the effects of denture adhesives on masticatory performance via a 10-center, parallel, randomized, controlled trial of complete denture wearers in Japan. METHODS: The trial was conducted between September 2013 and October 2016. The inclusion criteria were complete edentulism, willingness to undergo new complete denture treatment, and willingness to return for recall treatment. The exclusion criteria were age 90 years or older, presence of severe systemic illness, inability to understand the questionnaires, wearing metal base complete dentures, denture adhesive user, wearing prosthetics for maxillofacial defects, wearing complete dentures with tissue conditioners, and severe xerostomia. Randomization of the powder-type denture adhesive (powder), cream-type denture adhesive (cream), and control (saline) groups was performed using a sealed envelope system. Masticatory performance was measured using color-changeable chewing gum. Intervention blinding was not feasible. RESULTS: Sixty-seven control, 69 powder, and 64 cream participants are analyzed using the intention-to-treat principle. The participants in all groups show significantly improved masticatory performance at post-intervention (paired t-test with Bonferroni correction P < 0.0001). However, no significant difference in masticatory performance is detected among the three groups (one-way analysis of variance). A significant negative correlation between pre- and post-changes in masticatory performance and intraoral condition scores is observed (Pearson's correlation coefficient, P < 0.0001). CONCLUSIONS: Although denture adhesives improved the masticatory performance of complete denture wearers, their clinical effects are comparable to those of saline solution. The use of denture adhesives is more effective in complete denture wearers with unsatisfactory intraoral conditions.


Assuntos
Boca Edêntula , Perda de Dente , Humanos , Idoso de 80 Anos ou mais , Pós , Prótese Total , Goma de Mascar , Mastigação
17.
J Prosthodont Res ; 67(2): 262-270, 2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35831139

RESUMO

Purpose Denture adhesives improve the stability of incompatible dentures; however, complete removal of adhesives after use is difficult. Only a few studies have focused on the removal of denture adhesives. Hence, this study aimed to assess the efficacy of surfactants in removing cream denture adhesives from acrylic resin materials.Methods Solutions of twelve surfactants with various hydrophilic-lipophilic balance (HLB) values were prepared. Two cream denture adhesives, colored for visualization, were spread onto transparent acrylic resin plates. After immersion into surfactant solutions, the effects of the surfactants on residual adhesives were evaluated. We also investigated the effect of denture cleaners (with or without the surfactants) on the removability of adhesives and artificial oily dirt, and their effects on the surface properties of denture materials. The obtained data were analyzed using appropriate statistical methods.Results Five surfactants [BT-5, BL-4.2, BT-7, BT-9, and Triton X-100 (TX)] with HLB values in the 10.5-13.5 range effectively removed adhesives. Addition of BT-9 and TX (HLB=13.5) to denture cleaners improved the adhesives' removal. Furthermore, the addition of TX to the cleaners did not interfere with the removal of artificial oily dirt and did not damage the denture materials' surface.Conclusions Surfactants with HLB values in the 10.5-13.5 range are suitable for removal of cream denture adhesives from acrylic resin materials. In particular, TX (HLB=13.5) efficiently removes adhesives without damaging denture materials or impairing original detergency.


Assuntos
Cimentos Dentários , Tensoativos , Resinas Acrílicas , Propriedades de Superfície , Dentaduras , Retenção de Dentadura
18.
Cureus ; 15(9): e46001, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37900483

RESUMO

Background The aim of this study was to compare the responses of 30 denture wearers' opinions concerning the efficiency of two types of adhesives and estimate their satisfaction level using denture adhesive (DA). Materials and methods 30 completely edentulous patients were divided randomly into two groups. Each group received one type of DAs (SECURE, COREGA) and was instructed to follow the same sequence of application. Each type of adhesive was used for seven days, as recommended by the manufacturer. The patients were requested to fill out a questionnaire considering their opinion and satisfaction regarding denture retention, chewing ability and duration of adhesives. Results The majority of patients stated that the prosthetic DAs enhanced their retention, chewing, stability, and efficiency of dentures. There was a significant difference in patient satisfaction regarding denture retention in the mandible and the duration of the adhesive in the mouth. Concerning ability of the patient to remove the adhesive from their mouth, the taste, or the retention of the maxillary denture, there were no statistically significant differences between the two DAs. Conclusions The results of the present study showed that overall satisfaction of complete denture wearers was high significantly different when a herbal DA was applied. This includes improvements in their duration of retention effectiveness, greater stability, and retention of the lower mandibular dentures. To use DA effectively, patients should be oriented by their dentists. Patient education is essential to provide them with a better understanding of both the appropriate technique for applying DA and the possible outcome they may experience.

19.
J Clin Med ; 12(3)2023 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-36769520

RESUMO

The type of denture adhesive, cream or home-liner, chosen by regular denture adhesive users and oral conditions contributing to this selection require elucidation. The factors associated with denture adhesive selection were investigated through a face-to-face survey on oral and denture conditions. Age, sex, oral moisture, masticatory performance, retention and stability of the removable denture, ridge shape, mucosal thickness, and duration of denture use were examined in cream and home-liner-type denture adhesive users who did not regularly visit a dentist. Univariate analysis and multivariate analyses were performed. There were 38 and 40 cream-type and home-liner-type adhesive users, respectively. The type of denture adhesive was significantly associated with the oral moisture value, retention, ridge shape, mucosal thickness, and duration of denture use in univariate analyses. The residual ridge conditions with large factor loadings for ridge shape and mucosal thickness and duration of denture use were significantly related to the denture adhesive selection in multivariate logistic analysis. The residual ridge conditions and duration of denture use were significant factors in the selection of cream- and home-liner-type denture adhesives. These results can provide appropriate guidance based on the adhesives patients without dental supervision are more likely to choose.

20.
J Prosthodont Res ; 67(4): 548-555, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-36740264

RESUMO

PURPOSE: This study aimed to determine the effects of denture adhesives on denture retention and occlusal force in complete denture wearers in a multicenter, randomized, parallel-group controlled trial. METHODS: Two hundred edentulous patients wearing complete dentures were allocated to three groups: powder-type denture adhesive, cream-type denture adhesive, and control (saline solution). Denture adhesives and saline solution were applied to the dentures for 4 days. The retentive force of the dentures and occlusal force were measured using a force transducer occlusal force meter at baseline and after 4 days of intervention. In addition to between-group comparisons, subgroup analyses of denture retention and occlusal force were performed based on the level of difficulty of the edentulism treatment. The levels were ranked as I (easy), II, III, and IV (difficult). RESULTS: Cream-type denture adhesives significantly improved the retentive force of the dentures (P<0.01) and occlusal force (P<0.05), with no significant differences between baseline and post-intervention forces in the powder-type denture adhesive and control groups. In within-group comparisons, cream-type denture adhesives improved both the retentive and occlusal forces at Level II (P<0.05), and powder-type denture adhesives improved the occlusal force at Level II (P<0.01). CONCLUSIONS: Application of cream-type denture adhesives effectively improves the denture retention and occlusal force in complete denture wearers with a moderate degree of difficulty during edentulism treatment.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa