Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Endosc Int Open ; 12(4): E535-E544, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38720905

RESUMO

Background and study aims Endobiliary radiofrequency ablation (RFA) can be an effective palliative treatment, but few studies have evaluated its outcomes for malignant obstruction in the hilar bile duct, which has a thin wall and complex duct-vascular contacts. We evaluated the efficacy and safety of temperature-controlled endobiliary RFA, which can reduce the risk of unintentional thermal injury by maintaining the temperature of the ablation segment, in the treatment of inoperable hilar cholangiocarcinoma (CCA). Patients and methods After propensity score matching, 64 patients with inoperable hilar CCA were categorized to the RFA + stent group (endobiliary RFA with stenting; n=32) or stent-only group (stenting only; n=32). The evaluated outcomes were the median time to recurrent biliary obstruction (RBO), overall survival (OS), and adverse events (AEs). Results Technical success was achieved in all patients. The clinical success rate was 93.8% in the RFA + stent group and 87.5% in the stent-only group ( P =0.672). The median time to RBO was 242 days in the RFA + stent group and 168 days in the stent-only group ( P =0.031). The median OS showed a non-significant tendency to be higher in the RFA + stent group (337 versus 296 days; P =0.260). Overall AE rates were comparable between the two groups (12.5% vs 9.4%, P =1.000). Conclusions Temperature-controlled endobiliary RFA resulted in favorable stent patency without increasing the rate of AEs but it did not significantly increase OS in patients with inoperable hilar CCA (Clinical trial registration number: KCT0008576).

2.
Endosc Int Open ; 12(6): E772-E780, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38904060

RESUMO

Background and study aims Pancreatitis is a potentially lethal adverse event of endoscopic transpapillary placement of a self-expandable metal stent (SEMS) for malignant biliary obstruction (MBO). Deep learning-based image recognition has not been investigated in predicting pancreatitis in this setting. Patients and methods We included 70 patients who underwent endoscopic placement of a SEMS for nonresectable distal MBO. We constructed a convolutional neural network (CNN) model for pancreatitis prediction using a series of pre-procedure computed tomography images covering the whole pancreas (≥ 120,960 augmented images in total). We examined the additional effects of the CNN-based probabilities on the following machine learning models based on clinical parameters: logistic regression, support vector machine with a linear or RBF kernel, random forest classifier, and gradient boosting classifier. Model performance was assessed based on the area under the curve (AUC) in the receiver operating characteristic analysis, positive predictive value (PPV), accuracy, and specificity. Results The CNN model was associated with moderate levels of performance metrics: AUC, 0.67; PPV, 0.45; accuracy, 0.66; and specificity, 0.63. When added to the machine learning models, the CNN-based probabilities increased the performance metrics. The logistic regression model with the CNN-based probabilities had an AUC of 0.74, PPV of 0.85, accuracy of 0.83, and specificity of 0.96, compared with 0.72, 0.78, 0.77, and 0.96, respectively, without the probabilities. Conclusions The CNN-based model may increase predictability for pancreatitis following endoscopic placement of a biliary SEMS. Our findings support the potential of deep learning technology to improve prognostic models in pancreatobiliary therapeutic endoscopy.

3.
Endosc Int Open ; 12(7): E830-E841, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38966317

RESUMO

Background and study aims Biliary sphincterotomy is a crucial step in endoscopic retrograde cholangiopancreatography (ERCP), a procedure known to carry a 5% to 10% risk of complications. The relationship between Pure cut, Endocut, post-ERCP pancreatitis (PEP) and bleeding is unclear. This systematic review and meta-analysis compared these two current types and their relationships with adverse events. Patients and methods This systematic review involved searching articles in multiple databases until August 2023 comparing pure cut versus Endocut in biliary sphincterotomy. The meta-analysis followed the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). Results A total of 987 patients from four randomized controlled trials were included. Overall pancreatitis: A higher risk of pancreatitis was found in the Endocut group than in the Pure cut group ( P =0.001, RD=0.04 [range, 0.01 to 0.06]; I 2 =29%). Overall immediate bleeding: Statistical significance was found to favor Endocut, ( P =0.05; RD=-0.15 [range, -0.29 to -0.00]; I 2 =93%). No statistical significance between current modes was found in immediate bleeding without endoscopic intervention ( P =0.10; RD=-0.13 [range, -0.29 to 0.02]; I 2 =88%), immediate bleeding with endoscopic intervention ( P =0.06; RD=-0.07 [range, -0.14 to 0.00]; I 2 =76%), delayed bleeding (P=0.40; RD=0.01 [range, -0.02 to 0.05]; I 2 =72%), zipper cut ( P =0.58; RD=-0.03 [range, -0.16 to 0.09]; I 2 =97%), perforation ( P =1.00; RD=0.00 [range, -0.01 to 0.01]; I 2 =0%) and cholangitis ( P =0.77; RD=0.00 [range, -0.01 to 0.02]; I 2 =29%). Conclusions The available data in the literature show that Endocut carries an increased risk for PEP and does not prevent delayed or clinically significant bleeding, although it prevents intraprocedural bleeding. Based on such findings, Pure cut should be the preferred electric current mode for biliary sphincterotomy.

4.
Endosc Int Open ; 12(4): E561-E567, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38628392

RESUMO

Background and study aims Endoscopic transpapillary biliary forceps biopsy (TBFB) is a common method for obtaining specimens from biliary lesions. Its diagnostic yield is unsatisfactory; to overcome this disadvantage, a dedicated sheath has been developed. This study aimed to evaluate the outcomes of conventional TBFB and TBFB with a novel sheath device. Patients and methods Consecutive patients who underwent TBFB between January 2020 and December 2021 were retrospectively evaluated. The rate of obtaining adequate samples, failed attempts at forceps insertion into the bile duct, and sensitivity were compared between the two groups. Results Ninety-two patients who underwent 115 endoscopic retrograde cholangiopancreatographies (76 in the conventional group vs. 39 in the dedicated sheath group) were included. The rates of obtaining adequate samples, failed attempts of the forceps into the bile duct, and sensitivity were 72.4% vs. 89.7% ( P = 0.03), 28.3% vs. 0% ( P < 0.01), and 66.7% vs. 88.9% ( P = 0.02), respectively. Conclusions TBFB with the novel sheath device contributed to improved sensitivity for diagnosis of biliary stricture without insertion of forceps outside the bile duct.

5.
Endosc Int Open ; 12(2): E307-E316, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420157

RESUMO

Background and study aims Although the number of resistant bacteria tends to increase with prolonged antimicrobial therapy, no studies have examined the relationship between the duration of antimicrobial therapy and increase in the number of resistant bacteria in acute cholangitis. We hypothesized that the short-term administration of antimicrobial agents in acute cholangitis would suppress bacterial resistance. Patients and methods This was a single-center, retrospective, observational study of patients with acute cholangitis admitted between January 2018 and June 2020 who met the following criteria: successful biliary drainage, positive blood or bile cultures, bacteria identified from cultures sensitive to antimicrobials, and subsequent cholangitis recurrence by January 2022. The patients were divided into two groups: those whose causative organisms at the time of recurrence became resistant to the antimicrobial agents used at the time of initial admission (resistant group) and those who remained susceptible (susceptible group). Multivariate analysis was used to examine risk factors associated with the development of resistant pathogens. Multivariate analysis investigated antibiotics used with the length of 3 days or shorter after endoscopic retrograde cholangiopancreatography (ERCP) and previously reported risk factors for the development of bacterial resistance. Results In total, 89 eligible patients were included in this study. There were no significant differences in patient background or ERCP findings between the groups. The use of antibiotics, completed within 3 days after ERCP, was associated with a lower risk of developing bacterial resistance (odds ratio, 0.17; 95% confidence interval, 0.04-0.65; P =0.01). Conclusions In acute cholangitis, the administration of antimicrobials within 3 days of ERCP may suppress the development of resistant bacteria.

6.
Endosc Int Open ; 12(1): E59-E67, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38193008

RESUMO

Background and study aims Perioperative hypothermia is associated with significant complications and can be prevented with forced-air heating systems (FAHS). Whether hypothermia occurs during prolonged endoscopic sedation is unclear and prevention measures are not addressed in endoscopic sedation guidelines. We hypothesized that hypothermia also occurs in a significant proportion of patients undergoing endoscopic interventions associated with longer sedation times such as endoscopic retrograde cholangiopancreaticography (ERCP), and that FAHS may prevent it. Patients and methods In this observational study, each patient received two consecutive ERCPs, the first ERCP following current standard of care without FAHS (SOC group) and a consecutive ERCP with FAHS (FAHS group). The primary endpoint was maximum body temperature difference during sedation. Results Twenty-four patients were included. Median (interquartile range) maximum body temperature difference was -0.9°C (-1.2; -0.4) in the SOC and -0.1°C (-0.2; 0) in the FAHS group ( P < 0.001). Median body temperature was lower in the SOC compared with the FAHS group after 20, 30, 40, and 50 minutes of sedation. A reduction in body temperature of > 1°C ( P < 0.001) and a reduction below 36°C ( P = 0.01) occurred more often in the SOC than in the FAHS group. FAHS was independently associated with reduced risk of hypothermia ( P = 0.006). More patients experienced freezing in the SOC group ( P = 0.004). Hemodynmaic and respiratory stability were comparable in both groups. Conclusions Hypothermia occurred in the majority of patients undergoing prolonged endoscopic sedation without active temperature control. FAHS was associated with higher temperature stability during sedation and better patient comfort.

7.
Endosc Int Open ; 12(2): E324-E331, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420150

RESUMO

Background and study aims The Bethesda ERCP Skill Assessment Tool (BESAT) is a video-based assessment tool of technical endoscopic retrograde cholangiopancreatography (ERCP) skill with previously established validity evidence. We aimed to assess the discriminative validity of the BESAT in differentiating ERCP skill levels. Methods Twelve experienced ERCP practitioners from tertiary academic centers were asked to blindly rate 43 ERCP videos using the BESAT. ERCP videos consisted of native biliary cannulation and sphincterotomy and were recorded from 10 unique endoscopists of various ERCP experience (from advanced endoscopy fellow to > 10 years of ERCP experience). Inter-rater reliability, discriminative validity, and internal structure validity were subsequently assessed. Results The BESAT was found to reliably differentiate between endoscopists of varying levels of ERCP experience with experienced ERCPists scoring higher than novice ERCPists in 11 of 13 (85%) instrument items. Inter-rater reliability for BESAT items ranged from good to excellent (intraclass correlation range: 0.86 to 0.93). Internal structure validity was assessed with item-total correlations ranging from 0.53 to 0.83. Conclusions Study findings demonstrate that the BESAT, a video-based ERCP skill assessment tool, has high inter-rater reliability and has discriminative validity in differentiating novice from expert ERCP skill. Further investigations are needed to determine the role of video-based assessment in improving trainee learning curves and patient outcomes.

8.
Endosc Int Open ; 12(3): E419-E427, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38504744

RESUMO

Background and study aims Musculoskeletal disorders (MSDs) and injuries (MSIs) are frequent in gastrointestinal endoscopy. The aim of this study was to assess potential ergonomic advantages of a lighter single-use duodenoscope compared with a standard reusable one for endoscopists performing endoscopic retrograde cholangiopancreatography (ERCP). Methods Three experienced endoscopists performed an ergonomic, preclinical, comparative protocol-guided simulation study of a single-use and a standard reusable duodenoscope using an anatomic bench model. Surface EMG signals from left forearm and arm muscles were recorded. A commercial inertial sensor-based motion capture system was applied to record body posture as well. Results A significant lowering of root mean square amplitude and amplitude distribution of biceps brachii signal (ranging from 13% to 42%) was recorded in all the participants when using a single-use duodenoscope compared with a reusable one. An overall reduction of muscle activation amplitude and duration was also associated with the single-use duodenoscope for forearm muscles, with different behaviors among subjects. Participants spent most of the time in wrist extension (> 80%) and ulnar deviation (> 65%). A consistent pattern of functional range of motion employed for completing all procedures was observed. Conclusions Our study showed that a lighter scope has a promising effect in reducing upper arm muscle activity during ERCP with potential benefit on musculoskeletal health in the ERCP setting.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa