Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Ann Hematol ; 100(12): 2989-2995, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34430990

RESUMO

Minimal residual disease (MRD)-negative status in multiple myeloma (MM) is associated with favorable outcomes. Although EuroFlow next-generation flow (NGF) is a global standard for MRD detection, its operating cost is high. Therefore, it is desirable to develop a less expensive method with equivalent sensitivity to that of EuroFlow-NGF. In this study, we compared the analytical ability of our BML 10-color multiparameter flow cytometry (MFC) to that of EuroFlow-NGF. Bone marrow samples collected from 51 patients with MM were subjected to MRD detection using BML 10-color-MFC and EuroFlow-NGF. Our antibody panel consisted of CD38 multiepitope, CD138, CD45, CD56, CD19, CD27, CD81, CD117, cytoplasmic immunoglobulin (cIg) κ, and cIgλ in a single tube. The median percentages of total plasma cells, as per 10-color-MFC and EuroFlow-NGF, were 0.2148% and 0.2200%, respectively, with a good correlation between the methods (r = 0.950). The median percentages of myeloma cells determined via 10-color-MFC and EuroFlow-NGF were 0.0012% and 0.0007%, respectively, with a strong correlation (r = 0.954). Our 10-color-MFC demonstrated high sensitivity to detect MRD; the results showed a good correlation with those obtained using EuroFlow-NGF. Therefore, our cost-effective single-tube MFC (approximately 100 USD/sample) is a promising alternative method for the detection of MRD in patients with MM.


Assuntos
Citometria de Fluxo/métodos , Mieloma Múltiplo/diagnóstico , Neoplasia Residual/diagnóstico , Adulto , Idoso , Antígenos CD/análise , Medula Óssea/patologia , Feminino , Humanos , Imunoglobulinas/análise , Masculino , Pessoa de Meia-Idade
2.
Cytometry A ; 97(2): 137-147, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31593368

RESUMO

There is an agreement in the field that interlaboratory reproducibility of flow cytometry measurements as well as the whole studies might be improved by a consensual use of methodological approach. Typically, a consensus is made on a crucial markers needed in the immunostaining panel, sometimes on the particular fluorochrome conjugates and rarely on a complete set of methods for sample preparation. The term "standardization" is used to describe the complete set of methodical steps, while "harmonization" is used for partial agreement on the method. Standardization can provide a platform for improved reproducibility of cytometry results over prolonged periods of time, across different sites and across different instruments. For the purpose of structured discussion, several desired aims are described: common interpretation of the immunophenotype definition of a target subset, accurate quantification, reproducible pattern of a multicolor immunophenotype, and reproducible intensity of all measured parameters. An overview of how standardization was approached by several large consortia is provided: EuroFlow, The ONE Study, Human Immunology Project Consortium (HIPC), and several other groups. Their particular aims and the tools adopted to reach those aims are noted. How those standardization efforts were adopted in the field and how the resulting outcome was evaluated is reviewed. Multiple challenges in the instrument hardware design, instrument setup tools, reagent design, and quality features need to be addressed to achieve optimal standardization. Furthermore, the aims of different studies vary, and thus, the reasonable requirements for standardization differ. A framework of reference for the reasonable outcomes of different approaches is offered. Finally, it is argued that complete standardization is important not only for the reproducibility of measurements but also for education, for quality assessment and for algorithmic data analysis. The different standardized approaches can and in fact should serve as benchmarking reference tools for the development of future flow cytometry studies. © 2019 International Society for Advancement of Cytometry.


Assuntos
Citometria de Fluxo , Humanos , Imunofenotipagem , Indicadores e Reagentes , Padrões de Referência , Reprodutibilidade dos Testes
3.
Cytometry A ; 87(2): 145-56, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25345353

RESUMO

Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for laboratories that use standardized EuroFlow protocols. It may be used to complement, but not replace, established proficiency tests. © 2014 International Society for Advancement of Cytometry.


Assuntos
Citometria de Fluxo/métodos , Imunofenotipagem/métodos , Leucemia/diagnóstico , Subpopulações de Linfócitos/imunologia , Linfoma/diagnóstico , Europa (Continente) , Voluntários Saudáveis , Leucemia/classificação , Linfoma/classificação , Controle de Qualidade , Padrões de Referência , Valores de Referência
4.
Sci Rep ; 14(1): 10362, 2024 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710832

RESUMO

POEMS syndrome (polyneuropathy, organomegaly, endocrinopathy, monoclonal protein [M-protein], and skin changes) is a rare systemic disorder characterized by various symptoms caused by underlying plasma cell (PC) dyscrasia. Detection of monoclonal PCs is mandatory for the diagnosis of POEMS syndrome; however, the usefulness of EuroFlow-based next-generation flow cytometry (EuroFlow-NGF) in POEMS syndrome for detecting monoclonal PCs in bone marrow (BM) and the gating strategy suitable for flow cytometry study of POEMS syndrome remain unknown. We employed EuroFlow-NGF-based single-tube eight-color multiparameter flow cytometry (MM-flow) and established a new gating strategy (POEMS-flow) to detect the monoclonal PCs in POEMS syndrome, gating CD38 broadly from dim to bright and CD45 narrowly from negative to dim compared to MM-flow. MM-flow detected monoclonal PCs in 9/25 (36.0%) cases, including 2/2 immunofixation electrophoresis (IFE)-negative cases (100%). However, POEMS-flow detected monoclonal PCs in 18/25 cases (72.0%), including 2/2 IFE-negative cases (100%). POEMS-flow detected monoclonal PCs with immunophenotypes of CD19- in 17/18 (94.4%). In six cases where post-treatment samples were available, the size of the clones was significantly reduced after the treatment (P = 0.031). POEMS-flow can enhance the identification rate of monoclonal PCs in POEMS syndrome and become a valuable tool for the diagnosis of POEMS syndrome.


Assuntos
Citometria de Fluxo , Síndrome POEMS , Plasmócitos , Síndrome POEMS/diagnóstico , Humanos , Citometria de Fluxo/métodos , Pessoa de Meia-Idade , Masculino , Feminino , Idoso , Plasmócitos/metabolismo , Plasmócitos/patologia , Adulto , Imunofenotipagem/métodos , Medula Óssea/patologia
5.
Front Immunol ; 14: 1268686, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37915569

RESUMO

Background: Multiparameter flow cytometry (FC) immunophenotyping is a key tool for detailed identification and characterization of human blood leucocytes, including B-lymphocytes and plasma cells (PC). However, currently used conventional data analysis strategies require extensive expertise, are time consuming, and show limited reproducibility. Objective: Here, we designed, constructed and validated an automated database-guided gating and identification (AGI) approach for fast and standardized in-depth dissection of B-lymphocyte and PC populations in human blood. Methods: For this purpose, 213 FC standard (FCS) datafiles corresponding to umbilical cord and peripheral blood samples from healthy and patient volunteers, stained with the 14-color 18-antibody EuroFlow BIgH-IMM panel, were used. Results: The BIgH-IMM antibody panel allowed identification of 117 different B-lymphocyte and PC subsets. Samples from 36 healthy donors were stained and 14 of the datafiles that fulfilled strict inclusion criteria were analysed by an expert flow cytometrist to build the EuroFlow BIgH-IMM database. Data contained in the datafiles was then merged into a reference database that was uploaded in the Infinicyt software (Cytognos, Salamanca, Spain). Subsequently, we compared the results of manual gating (MG) with the performance of two classification algorithms -hierarchical algorithm vs two-step algorithm- for AGI of the cell populations present in 5 randomly selected FCS datafiles. The hierarchical AGI algorithm showed higher correlation values vs conventional MG (r2 of 0.94 vs. 0.88 for the two-step AGI algorithm) and was further validated in a set of 177 FCS datafiles against conventional expert-based MG. For virtually all identifiable cell populations a highly significant correlation was observed between the two approaches (r2>0.81 for 79% of all B-cell populations identified), with a significantly lower median time of analysis per sample (6 vs. 40 min, p=0.001) for the AGI tool vs. MG, respectively and both intra-sample (median CV of 1.7% vs. 10.4% by MG, p<0.001) and inter-expert (median CV of 3.9% vs. 17.3% by MG by 2 experts, p<0.001) variability. Conclusion: Our results show that compared to conventional FC data analysis strategies, the here proposed AGI tool is a faster, more robust, reproducible, and standardized approach for in-depth analysis of B-lymphocyte and PC subsets circulating in human blood.


Assuntos
Linfócitos B , Plasmócitos , Humanos , Reprodutibilidade dos Testes , Imunofenotipagem , Leucócitos
6.
Cancers (Basel) ; 14(8)2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35454917

RESUMO

Flowcytometric analysis allows for detailed identification and characterization of large numbers of cells in blood, bone marrow, and other body fluids and tissue samples and therefore contributes to the diagnostics of hematological malignancies. Novel data analysis tools allow for multidimensional analysis and comparison of patient samples with reference databases of normal, reactive, and/or leukemia/lymphoma patient samples. Building such reference databases requires strict quality assessment (QA) procedures. Here, we compiled a dataset and developed a QA methodology of the EuroFlow Acute Myeloid Leukemia (AML) database, based on the eight-color EuroFlow AML panel consisting of six different antibody combinations, including four backbone markers. In total, 1142 AML cases and 42 normal bone marrow samples were included in this analysis. QA was performed on 803 AML cases using multidimensional analysis of backbone markers, as well as tube-specific markers, and data were compared using classical analysis employing median and peak expression values. Validation of the QA procedure was performed by re-analysis of >300 cases and by running an independent cohort of 339 AML cases. Initial evaluation of the final cohort confirmed specific immunophenotypic patterns in AML subgroups; the dataset therefore can reliably be used for more detailed exploration of the immunophenotypic variability of AML. Our data show the potential pitfalls and provide possible solutions for constructing large flowcytometric databases. In addition, the provided approach may facilitate the building of other databases and thereby support the development of novel tools for (semi)automated QA and subsequent data analysis.

7.
Cancers (Basel) ; 14(6)2022 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-35326734

RESUMO

Acute megakaryoblastic leukemia (AMKL) is a rare and heterogeneous subtype of acute myeloid leukemia (AML). We evaluated the immunophenotypic profile of 72 AMKL and 114 non-AMKL AML patients using the EuroFlow AML panel. Univariate and multivariate/multidimensional analyses were performed to identify most relevant markers contributing to the diagnosis of AMKL. AMKL patients were subdivided into transient abnormal myelopoiesis (TAM), myeloid leukemia associated with Down syndrome (ML-DS), AML-not otherwise specified with megakaryocytic differentiation (NOS-AMKL), and AMKL-other patients (AML patients with other WHO classification but with flowcytometric features of megakaryocytic differentiation). Flowcytometric analysis showed good discrimination between AMKL and non-AMKL patients based on differential expression of, in particular, CD42a.CD61, CD41, CD42b, HLADR, CD15 and CD13. Combining CD42a.CD61 (positive) and CD13 (negative) resulted in a sensitivity of 71% and a specificity of 99%. Within AMKL patients, TAM and ML-DS patients showed higher frequencies of immature CD34+/CD117+ leukemic cells as compared to NOS-AMKL and AMKL-Other patients. In addition, ML-DS patients showed a significantly higher expression of CD33, CD11b, CD38 and CD7 as compared to the other three subgroups, allowing for good distinction of these patients. Overall, our data show that the EuroFlow AML panel allows for straightforward diagnosis of AMKL and that ML-DS is associated with a unique immunophenotypic profile.

8.
Am J Clin Pathol ; 157(4): 494-497, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34643211

RESUMO

OBJECTIVES: To compare flow cytometric minimal residual disease (MRD) data obtained using the EuroFlow approach, including the CD38-multiepitope (ME) antibody or the VS38c antibody. METHODS: We evaluated 29 bone marrow samples from patients with multiple myeloma (MM), of whom 15 had received daratumumab within the past 6 months. We evaluated MRD data and fluorescence intensities. RESULTS: Qualitative MRD data were 100% concordant between the 2 approaches. In MRD-positive samples (n = 14), MRD levels showed an excellent correlation (R2 = 0.999). Whereas VS38c staining was strong in both normal plasma cells and MM cells, independent of daratumumab treatment, staining intensities for CD38 were lower in MM cells compared with normal plasma cells, and on both cell types CD38 expression was significantly reduced in daratumumab-treated patients. CONCLUSIONS: Both CD38-ME and VS38c allow reliable MRD detection in MM patients, but the high expression of VS38c allows easier identification of MM cells, especially in daratumumab-treated patients.


Assuntos
ADP-Ribosil Ciclase 1 , Anticorpos Antineoplásicos , Glicoproteínas de Membrana , Mieloma Múltiplo , ADP-Ribosil Ciclase 1/imunologia , Anticorpos Monoclonais/uso terapêutico , Anticorpos Antineoplásicos/imunologia , Contagem de Células , Epitopos , Citometria de Fluxo , Humanos , Glicoproteínas de Membrana/imunologia , Mieloma Múltiplo/diagnóstico , Mieloma Múltiplo/tratamento farmacológico , Mieloma Múltiplo/imunologia , Neoplasia Residual/diagnóstico , Neoplasia Residual/imunologia , Plasmócitos
9.
Front Immunol ; 13: 937738, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36177024

RESUMO

Introduction: Multiparameter flow cytometry (FCM) immunophenotyping is an important tool in the diagnostic screening and classification of primary immunodeficiencies (PIDs). The EuroFlow Consortium recently developed the PID Orientation Tube (PIDOT) as a universal screening tool to identify lymphoid-PID in suspicious patients. Although PIDOT can identify different lymphoid-PIDs with high sensitivity, clinical validation in a broad spectrum of patients with suspicion of PID is missing. In this study, we investigated the diagnostic performance of PIDOT, as part of the EuroFlow diagnostic screening algorithm for lymphoid-PID, in a daily practice at a tertiary reference center for PID. Methods: PIDOT was tested in 887 consecutive patients suspicious of PID at the Ghent University Hospital, Belgium. Patients were classified into distinct subgroups of lymphoid-PID vs. non-PID disease controls (non-PID DCs), according to the IUIS and ESID criteria. For the clinical validation of PIDOT, comprehensive characterization of the lymphoid defects was performed, together with the identification of the most discriminative cell subsets to distinguish lymphoid-PID from non-PID DCs. Next, a decision-tree algorithm was designed to guide subsequent FCM analyses. Results: The mean number of lymphoid defects detected by PIDOT in blood was 2.87 times higher in lymphoid-PID patients vs. non-PID DCs (p < 0.001), resulting in an overall sensitivity and specificity of 87% and 62% to detect severe combined immunodeficiency (SCID), combined immunodeficiency with associated or syndromic features (CID), immune dysregulation disorder (ID), and common variable immunodeficiency (CVID). The most discriminative populations were total memory and switched memory B cells, total T cells, TCD4+cells, and naive TCD4+cells, together with serum immunoglobulin levels. Based on these findings, a decision-tree algorithm was designed to guide further FCM analyses, which resulted in an overall sensitivity and specificity for all lymphoid-PIDs of 86% and 82%, respectively. Conclusion: Altogether, our findings confirm that PIDOT is a powerful tool for the diagnostic screening of lymphoid-PID, particularly to discriminate (S)CID, ID, and CVID patients from other patients suspicious of PID. The combination of PIDOT and serum immunoglobulin levels provides an efficient guide for further immunophenotypic FCM analyses, complementary to functional and genetic assays, for accurate PID diagnostics.


Assuntos
Imunodeficiência de Variável Comum , Doença Inflamatória Pélvica , Doenças da Imunodeficiência Primária , Feminino , Citometria de Fluxo/métodos , Hospitais Universitários , Humanos , Imunoglobulinas , Imunofenotipagem , Doenças da Imunodeficiência Primária/diagnóstico
10.
Cancers (Basel) ; 15(1)2022 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-36612056

RESUMO

Reference ranges of blood-circulating leukocyte populations by, e.g., age and sex, are required for monitoring immune-cell kinetics. Most previous reports in which flow cytometry has been used to define the reference ranges for leukocyte counts included a limited number of donors and/or cell populations and/or did not consider age and sex simultaneously. Moreover, other factors not previously considered in the definition of normal ranges, such as the presence of chronic-lymphocytic-leukemia (CLL)-like low-count monoclonal B-cell lymphocytosis (MBLlo), might also be associated with an altered distribution of leukocytes in blood in association with an immunodeficiency and increased risk of infection and cancer. Here, we established reference cell-count ranges for the major populations of leukocytes in blood of non-MBL and MBLlo adult Caucasians matched by age and sex using the EuroFlow Lymphocyte Screening Tube (LST). A total of 706 Caucasian adult donors­622 non-MBL and 84 MBLlo­were recruited from the general population. Among non-MBL donors, the total leukocyte, neutrophil, basophil dendritic cell and monocyte counts remained stable through adulthood, while the absolute numbers of T- and B-cell populations and plasma cells decreased with age. The number of eosinophils and NK-cell increased over time, with clear differences according to sex for certain age ranges. In MBLlo subjects, few differences in the absolute cell counts by age (vs. non-MBL) were observed, and MBLlo men and women showed similar trends to non-MBL subjects except for the B-cell count drop observed in >70 y-men, which was more pronounced in MBLlo vs. non-MBL controls. Building robust age- and sex-matched reference ranges for the most relevant immune-cell populations in the blood of non-MBL donors is essential to appropriately identify an altered immune status in different clinical settings and highlight the altered immune-cell profiles of MBLlo subjects.

11.
Amyloid ; 28(1): 19-23, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32783569

RESUMO

The treatment of AL amyloidosis aims to eradicate the plasma cell clone and eliminate toxic free light chain production. Only in a minority of patients the plasma cell clone is completely eradicated; residual light chain production may still exist while clonal relapse may occur. We used sensitive next-generation flow cytometry (NGF) to detect minimal residual disease (MRD) in AL amyloidosis patients at complete haematologic response. MRD evaluation was feasible in 51 of 52 (98%) tested patients and at a median sensitivity of 2.3 × 10-6 MRD was undetectable in 23 (45%). An organ response occurred in 86% of MRDneg vs 77% in MRDpos; renal response in 15/17(88%) of MRDneg vs in 14/16(87.5%) of MRDpos and cardiac response in 10/10(100%) of MRDneg vs 11/15(73%) of MRDpos patients. After a median follow-up of 24 months post MRD testing, no MRDneg patient had a haematologic relapse vs 6/28(21%) MRDpos (p = .029). Pooling haematologic and organ progressions, 9 (32%) MRDpos patients had disease progression vs only 1 (4%) MRDneg patient (p = .026). In conclusion, MRD detection using NGF has profound clinical implications, so that AL patients with undetectable MRD have a very high probability of organ response and a very low probability of haematologic relapse.


Assuntos
Citometria de Fluxo/métodos , Amiloidose de Cadeia Leve de Imunoglobulina/sangue , Peptídeo Natriurético Encefálico/sangue , Neoplasia Residual/sangue , Adulto , Idoso , Células da Medula Óssea/patologia , Células da Medula Óssea/ultraestrutura , Feminino , Humanos , Amiloidose de Cadeia Leve de Imunoglobulina/complicações , Amiloidose de Cadeia Leve de Imunoglobulina/patologia , Masculino , Pessoa de Meia-Idade , Neoplasia Residual/complicações , Neoplasia Residual/diagnóstico , Neoplasia Residual/patologia , Plasmócitos/patologia , Plasmócitos/ultraestrutura , Prognóstico
12.
Front Immunol ; 11: 584646, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33224147

RESUMO

Background: Multiparameter flow cytometry (FC) is essential in the diagnostic work-up and classification of primary immunodeficiency (PIDs). The EuroFlow PID Orientation tube (PIDOT) allows identification of all main lymphocyte subpopulations in blood. To standardize data analysis, tools for Automated Gating and Identification (AG&I) of the informative cell populations, were developed by EuroFlow. Here, we evaluated the contribution of these innovative AG&I tools to the standardization of FC in the diagnostic work-up of PID, by comparing AG&I against expert-based (EuroFlow-standardized) Manual Gating (MG) strategy, and its impact on the reproducibility and clinical interpretation of results. Methods: FC data files from 44 patients (13 CVID, 12 PID, 19 non-PID) and 26 healthy donor (HD) blood samples stained with PIDOT were analyzed in parallel by MG and AG&I, using Infinicyt™ software (Cytognos). For comparison, percentage differences in absolute cell counts/µL were calculated for each lymphocyte subpopulation. Data files showing differences >20% were checked for their potential clinical relevance, based on age-matched percentile (p5-p95) reference ranges. In parallel, intra- and inter-observer reproducibility of MG vs AG&I were evaluated in a subset of 12 samples. Results: The AG&I approach was able to identify the vast majority of lymphoid events (>99%), associated with a significantly higher intra- and inter-observer reproducibility compared to MG. For most HD (83%) and patient (68%) samples, a high degree of agreement (<20% numerical differences in absolute cell counts/µL) was obtained between MG and the AG&I module. This translated into a minimal impact (<5% of observations) on the final clinical interpretation. In all except three samples, extended expert revision of the AG&I approach revealed no error. In the three remaining samples aberrant maturation and/or abnormal marker expression profiles were seen leading in all three cases to numerical alarms by AG&I. Conclusion: Altogether, our results indicate that replacement of MG by the AG&I module would be associated with a greater reproducibility and robustness of results in the diagnostic work-up of patients suspected of PID. However, expert revision of the results of AG&I of PIDOT data still remains necessary in samples with numerical alterations and aberrant B- and T-cell maturation and/or marker expression profiles.


Assuntos
Citometria de Fluxo/métodos , Doenças da Imunodeficiência Primária/diagnóstico , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Imunofenotipagem/métodos , Subpopulações de Linfócitos/patologia , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Doenças da Imunodeficiência Primária/patologia , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes , Software , Adulto Jovem
13.
Front Immunol ; 11: 603972, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33679693

RESUMO

Introduction: Common Variable Immunodeficiency (CVID) is characterized by defective antibody production and hypogammaglobulinemia. Flow cytometry immunophenotyping of blood lymphocytes has become of great relevance for the diagnosis and classification of CVID, due to an impaired differentiation of mature post-germinal-center (GC) class-switched memory B-cells (MBC) and severely decreased plasmablast/plasma cell (Pb) counts. Here, we investigated in detail the pre-GC B-cell maturation compartment in blood of CVID patients. Methods: In this collaborative multicentric study the EuroFlow PID 8-color Pre-GC B-cell tube, standardized sample preparation procedures (SOPs) and innovative data analysis tools, were used to characterize the maturation profile of pre-GC B-cells in 100 CVID patients, vs 62 age-matched healthy donors (HD). Results: The Pre-GC B-cell tube allowed identification within pre-GC B-cells of three subsets of maturation associated immature B-cells and three subpopulations of mature naïve B-lymphocytes. CVID patients showed overall reduced median absolute counts (vs HD) of the two more advanced stages of maturation of both CD5+ CD38+/++ CD21het CD24++ (2.7 vs 5.6 cells/µl, p=0.0004) and CD5+ CD38het CD21+ CD24+ (6.5 vs 17 cells/µl, p<0.0001) immature B cells (below normal HD levels in 22% and 37% of CVID patients). This was associated with an expansion of CD21-CD24- (6.1 vs 0.74 cells/µl, p<0.0001) and CD21-CD24++ (1.8 vs 0.4 cells/µl, p<0.0001) naïve B-cell counts above normal values in 73% and 94% cases, respectively. Additionally, reduced IgMD+ (21 vs 32 cells/µl, p=0.03) and IgMD- (4 vs 35 cells/µl, p<0.0001) MBC counts were found to be below normal values in 25% and 77% of CVID patients, respectively, always together with severely reduced/undetectable circulating blood pb. Comparison of the maturation pathway profile of pre-GC B cells in blood of CVID patients vs HD using EuroFlow software tools showed systematically altered patterns in CVID. These consisted of: i) a normally-appearing maturation pathway with altered levels of expression of >1 (CD38, CD5, CD19, CD21, CD24, and/or smIgM) phenotypic marker (57/88 patients; 65%) for a total of 3 distinct CVID patient profiles (group 1: 42/88 patients, 48%; group 2: 8/88, 9%; and group 3: 7/88, 8%) and ii) CVID patients with a clearly altered pre-GC B cell maturation pathway in blood (group 4: 31/88 cases, 35%). Conclusion: Our results show that maturation of pre-GC B-cells in blood of CVID is systematically altered with up to four distinctly altered maturation profiles. Further studies, are necessary to better understand the impact of such alterations on the post-GC defects and the clinical heterogeneity of CVID.


Assuntos
Imunodeficiência de Variável Comum/imunologia , Citometria de Fluxo , Imunofenotipagem , Células Precursoras de Linfócitos B/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antígenos CD/análise , Estudos de Casos e Controles , Imunodeficiência de Variável Comum/diagnóstico , Imunodeficiência de Variável Comum/metabolismo , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fenótipo , Células Precursoras de Linfócitos B/metabolismo , Adulto Jovem
14.
Front Immunol ; 11: 371, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32265901

RESUMO

The EuroFlow PID consortium developed a set of flow cytometry tests for evaluation of patients with suspicion of primary immunodeficiency (PID). In this technical report we evaluate the performance of the SCID-RTE tube that explores the presence of recent thymic emigrants (RTE) together with T-cell activation status and maturation stages and discuss its applicability in the context of the broader EuroFlow PID flow cytometry testing algorithm for diagnostic orientation of PID of the lymphoid system. We have analyzed peripheral blood cells of 26 patients diagnosed between birth and 2 years of age with a genetically defined primary immunodeficiency disorder: 15 severe combined immunodeficiency (SCID) patients had disease-causing mutations in RAG1 or RAG2 (n = 4, two of them presented with Omenn syndrome), IL2RG (n = 4, one of them with confirmed maternal engraftment), NHEJ1 (n = 1), CD3E (n = 1), ADA (n = 1), JAK3 (n = 3, two of them with maternal engraftment) and DCLRE1C (n = 1) and 11 other PID patients had diverse molecular defects [ZAP70 (n = 1), WAS (n = 2), PNP (n = 1), FOXP3 (n = 1), del22q11.2 (DiGeorge n = 4), CDC42 (n = 1) and FAS (n = 1)]. In addition, 44 healthy controls in the same age group were analyzed using the SCID-RTE tube in four EuroFlow laboratories using a standardized 8-color approach. RTE were defined as CD62L+CD45RO-HLA-DR-CD31+ and the activation status was assessed by the expression of HLA-DR+. Naïve CD8+ T-lymphocytes and naïve CD4+ T-lymphocytes were defined as CD62L+CD45RO-HLA-DR-. With the SCID-RTE tube, we identified patients with PID by low levels or absence of RTE in comparison to controls as well as low levels of naïve CD4+ and naïve CD8+ lymphocytes. These parameters yielded 100% sensitivity for SCID. All SCID patients had absence of RTE, including the patients with confirmed maternal engraftment or oligoclonally expanded T-cells characteristic for Omenn syndrome. Another dominant finding was the increased numbers of activated CD4+HLA-DR+ and CD8+HLA-DR+ lymphocytes. Therefore, the EuroFlow SCID-RTE tube together with the previously published PIDOT tube form a sensitive and complete cytometric diagnostic test suitable for patients suspected of severe PID (SCID or CID) as well as for children identified via newborn screening programs for SCID with low or absent T-cell receptor excision circles (TRECs).


Assuntos
Citometria de Fluxo/métodos , Imunofenotipagem/métodos , Doenças da Imunodeficiência Primária/diagnóstico , Linfócitos T/imunologia , Timo/imunologia , Pré-Escolar , Feminino , Antígenos HLA-DR/análise , Humanos , Lactente , Recém-Nascido , Masculino , Doenças da Imunodeficiência Primária/imunologia , Imunodeficiência Combinada Severa/imunologia
15.
Cancers (Basel) ; 12(8)2020 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-32824635

RESUMO

In order to meet the challenges in data evaluation and comparability between studies in multiple myeloma (MM) minimal residual disease (MRD) assessment, the goal of the current study was to provide a step-by-step evaluation of next-generation sequencing (NGS) and multicolor flow cytometry (MFC) data. Bone marrow (BM) sample pairs from 125 MM patients were analyzed by NGS and MFC MM MRD methods. Tumor load (TL) and limit of detection (LOD) and quantification (LOQ) were calculated. The best-fit MRD cut-off was chosen as 1 × 10-5, resulting in an overall 9.6% (n overall = 12 (NGS n = 2, MFC n = 10)) nonassessable cases. The overall concordance rate between NGS and MFC was 68.0% (n = 85); discordant results were found in 22.4% (11.2% (n = 14) of cases in each direction. Overall, 55.1% (n = 60/109) and 49.5% (n = 54/109) of patients with a serological response ≥ very good partial response (VGPR) showed BM MRD negativity by NGS and MFC, respectively. A good correlation in the TL assessed by both techniques was found (correlation coefficient = 0.8, n = 40, p < 0.001). Overall, our study shows good concordance between MM BM MRD status and TL when comparing NGS and MFC at a threshold of 10-5. However, a sufficient number of analyzed events and calculation of MRD key metrics are essential for the comparison of methods and evaluability of data at a specific MRD cut-off.

16.
J Immunol Methods ; 475: 112388, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-29154914

RESUMO

A critical component of the EuroFlow standardization of leukemia/lymphoma immunophenotyping is instrument setup. Initially, the EuroFlow consortium developed a step-by-step standard operating protocol for instrument setup of ≥8-color flow cytometers that were available in 2006, when the EuroFlow activities started. Currently, there are 14 instruments from 9 manufacturers capable of 3-laser excitation and ≥8 color measurements. The specific adaptations required in the instrument set-up to enable them to acquire the standardized 8-color EuroFlow protocols are described here. Overall, all 14 instruments can be fitted with similar violet, blue and red lasers for simultaneous measurements of ≥8 fluorescent dyes. Since individual instruments differ both on their dynamic range (scale) and emission filters, it is not accurate to simply recalculate the target values to different scale, but adjustment of PMT voltages to a given emission filter and fluorochrome, is essential. For this purpose, EuroFlow has developed an approach using Type IIB (spectrally matching) particles to set-up standardized and fully comparable fluorescence measurements, in instruments from different manufacturers, as demonstrated here for the FACSCanto II, and Navios and MACSQuant flow cytometers. Data acquired after such adjustment on any of the tested cytometry platforms could be fully superimposed and therefore analyzed together. The proposed approach can be used to derive target values for any combination of spectrally distinct fluorochromes and any distinct emission filter of any new flow cytometry platform, which enables the measurement of the 8-color EuroFlow panels in a standardized way, by creating superimposable datafiles.


Assuntos
Citometria de Fluxo/instrumentação , Citometria de Fluxo/normas , Neoplasias Hematológicas/diagnóstico , Imunofenotipagem/instrumentação , Imunofenotipagem/normas , Humanos
17.
J Immunol Methods ; 475: 112520, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-30237053

RESUMO

EuroFlow Quality Assessment was designed to provide a feedback on the quality of the standardization effort in executing the EuroFlow protocols for sample preparation and instrument setup. It was first beta-tested by the members of the EuroFlow consortium internally (2010-2013) and opened to the external participants from 2015 onwards. The goal of participation in the EuroFlow QA is to evaluate whether the technical quality of the data generated by the laboratory is comparable to the data of the EuroFlow members and thus if a non-EuroFlow member participant can use the EuroFlow reference sample database for his own patient evaluation. Also it assesses whether data are sufficiently standardized for automated population gating and alarm notification. By spring 2018, a total 87 laboratories from 32 countries on five continents have registered for the EuroFlow QA program. We evaluated 163 results of 2015-2016 QA rounds, where we noted clear improvement in the score of first-time participants (median score of 91% correct) when they participated second time or later (median score of 94% correct, p = 0,017), which was comparable to EuroFlow member scores (median score of 97% correct). Among frequent mistakes, we found non-adherence to the EuroFlow protocols (improper reagent used), improper gating and some compensation issues. In summary, we show that EuroFlow QA has a positive impact on improvement of standardized data quality of non-member laboratories adhering to the EuroFlow standard operating procedures and reagent panels.


Assuntos
Citometria de Fluxo/normas , Laboratórios/normas , Ensaio de Proficiência Laboratorial/métodos , Humanos , Padrões de Referência
18.
J Immunol Methods ; 475: 112680, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31655051

RESUMO

This commentary discusses particularities of application of the EuroFlow standardization of flow cytometric analyses on three different flow cytometers. The EuroFlow consortium developed a fully standardized approach for flow cytometric immunophenotyping of hematological malignancies and primary immunodeficiencies. Standardized instrument setup is an essential part of EuroFlow standardization. Initially, the EuroFlow Consortium developed and optimized a step-by-step standard operating procedure (SOP) to setup 8-color BD FACSCanto II flow cytometer (Canto), with the later inclusion of Navios (Beckman Coulter) and BD FACSLyric (Lyric). Those SOPs were developed to enable standardized and fully comparable fluorescence measurements in the three flow cytometers. In Canto and Navios, mean fluorescence intensity (MFI) of a reference peak of Rainbow beads calibration particles is used to set up photomultiplier (PMT) voltages for each detector channel in individual instruments to reach the same MFI across distinct instruments. In turn, a new feature of Lyric instruments allows to share collection of attributes that are used to place the positive population at the same position among instruments in the form of assays, as one of its components integrated in the Cytometer Setup and Tracking (CS&T) module. The EuroFlow Lyric assays thus allow for standardized acquisition of 8-color EuroFlow panels on Lyric without the need to setup the PMT voltages on the individual instruments manually. In summary, the standardized instrument setup developed by EuroFlow enables cross-platform inter- and intra-laboratory standardization of flow cytometric measurements. This commentary provides a perspective on the modifications of the standardized EuroFlow instrument setup of Canto, Navios and Lyric instruments that are described in detail in individual instrument-specfic SOPs available at the EuroFlow website.


Assuntos
Citometria de Fluxo/instrumentação , Citometria de Fluxo/normas , Imunofenotipagem/instrumentação , Imunofenotipagem/normas , Humanos , Padrões de Referência
19.
J Immunol Methods ; 475: 112348, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-28760670

RESUMO

The EuroFlow Consortium developed a fully standardized flow cytometric approach from instrument settings, through antibody panel, reagents and sample preparation protocols, to data acquisition and analysis. The Swiss Cytometry Society (SCS) promoted a study to evaluate the feasibility of using such standardized measurements of 8-color data across two different flow cytometry platforms - Becton Dickinson (BD) FACSCanto II and Beckman Coulter (BC) Navios, aiming at increasing reproducibility and inter-laboratory comparability of immunophenotypic data in clinical laboratories in Switzerland. The study was performed in two phases, i.e. a learning phase (round 1) and an analytical phase (rounds 2 and 3) consisting of a total of three rounds. Overall, 10 laboratories using BD FACSCanto II (n=6) or BC Navios (n=4) flow cytometers participated. Each laboratory measured peripheral blood samples from healthy donors stained with a uniform antibody panel of reagents - EuroFlow Lymphoid Screening Tube (LST) - applying the EuroFlow standardized protocols for instrument setup and sample preparation (www.EuroFlow.org). All data files were analyzed centrally and median fluorescence intensity (MedFI) values for individual markers on defined lymphocyte subsets were recorded; variability from reference MedFI values was assessed using performance scores. Data troubleshooting and discussion of the results with the participants followed after each round at SCS meetings. The results of the learning phase demonstrated that standardized instrument setup and data acquisition are feasible in routine clinical laboratories without previous experience with EuroFlow. During the analytical phase, highly comparable data were obtained at the different laboratories using either BD FACSCanto II or BC Navios. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%. In the last study round, 89% of participants scored over 90% MedFI values within the acceptance criteria (P-score), in line with the results of the EuroFlow quality assessment rounds performed by the EuroFlow expert laboratories(Kalina et al., 2015). Central analysis of data allowed identification of deviations from the standardized procedures and technical issues (e.g. failure to perform correct instrument setup and improper compensation). In summary, here we show that inter-laboratory cross-platform standardization of 8-color flow cytometric measurements in clinical laboratories is feasible and allows for fully comparable MedFI results across BD FACSCanto II and BC Navios instruments. However, adherence to standardized protocols is crucial. Thus, training of the laboratory personnel in the EuroFlow standardized procedures is highly recommended to prevent errors in instrument setup and sample preparation.


Assuntos
Citometria de Fluxo/instrumentação , Citometria de Fluxo/normas , Imunofenotipagem/instrumentação , Imunofenotipagem/normas , Serviços de Laboratório Clínico/normas , Estudos de Viabilidade , Humanos , Suíça
20.
Front Immunol ; 10: 246, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30886612

RESUMO

In the rapidly evolving field of primary immunodeficiencies (PID), the EuroFlow consortium decided to develop a PID orientation and screening tube that facilitates fast, standardized, and validated immunophenotypic diagnosis of lymphoid PID, and allows full exchange of data between centers. Our aim was to develop a tool that would be universal for all lymphoid PIDs and offer high sensitivity to identify a lymphoid PID (without a need for specificity to diagnose particular PID) and to guide and prioritize further diagnostic modalities and clinical management. The tube composition has been defined in a stepwise manner through several cycles of design-testing-evaluation-redesign in a multicenter setting. Equally important appeared to be the standardized pre-analytical procedures (sample preparation and instrument setup), analytical procedures (immunostaining and data acquisition), the software analysis (a multidimensional view based on a reference database in Infinicyt software), and data interpretation. This standardized EuroFlow concept has been tested on 250 healthy controls and 99 PID patients with defined genetic defects. In addition, an application of new EuroFlow software tools with multidimensional pattern recognition was designed with inclusion of maturation pathways in multidimensional patterns (APS plots). The major advantage of the EuroFlow approach is that data can be fully exchanged between different laboratories in any country of the world, which is especially of interest for the PID field, with generally low numbers of cases per center.


Assuntos
Citometria de Fluxo/métodos , Sistema Imunitário/patologia , Doenças da Imunodeficiência Primária/diagnóstico , Adolescente , Adulto , Idoso , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Humanos , Imunofenotipagem/métodos , Lactente , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa