Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 166
Filtrar
1.
BMC Anesthesiol ; 24(1): 331, 2024 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-39289607

RESUMO

BACKGROUND: Hysteroscopic surgery is a safe procedure used for diagnosing and treating intrauterine lesions, with a low rate of intraoperative complications. However, it is important to be cautious as fluid overload can still occur when performing any hysteroscopic surgical technique. CASE PRESENTATION: In this case report, we present a unique instance where lung ultrasound was utilized to diagnose pulmonary edema in a patient following a hysteroscopic myomectomy procedure. The development of pulmonary edema was attributed to the excessive absorption of fluid during the surgical intervention. By employing lung ultrasound as a diagnostic tool, we were able to promptly identify and address the pulmonary edema. As a result, the patient received timely treatment with no complications. This case highlights the importance of utilizing advanced imaging techniques, such as lung ultrasound, in the perioperative management of patients undergoing hysteroscopic procedures. CONCLUSIONS: This case report underscores the significance of early detection and intervention in preventing complications associated with fluid overload during hysteroscopic myomectomy procedures.


Assuntos
Histeroscopia , Edema Pulmonar , Ultrassonografia , Miomectomia Uterina , Humanos , Feminino , Edema Pulmonar/etiologia , Edema Pulmonar/diagnóstico por imagem , Histeroscopia/métodos , Miomectomia Uterina/efeitos adversos , Miomectomia Uterina/métodos , Ultrassonografia/métodos , Adulto , Pulmão/diagnóstico por imagem , Neoplasias Uterinas/cirurgia , Complicações Intraoperatórias/diagnóstico por imagem , Complicações Intraoperatórias/etiologia
2.
Indian J Crit Care Med ; 28(2): 165-169, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38323257

RESUMO

Background: Lung ultrasound (LUS) is a simple bedside tool to assess overhydration. Our study aimed to assess extravascular lung water (EVLW) using B-lines and correlate it with weaning, duration of mechanical ventilation, and mortality in critically ill patients admitted to the intensive care unit (ICU). Patients and methods: 150 mechanically ventilated ICU patients prospectively observed over 18 months, with their demographic and clinical data noted. Extravascular lung water was monitored using LUS in four intercostal spaces (ICS) from day 1 to day 5, day 7, day 10, and weekly thereafter. Pulmonary fluid burden was graded as low (1-10), moderate (11-20), and high (21-32). Weaning outcome, duration of weaning, mechanical ventilation, ICU stay, and mortality were compared in patients with and without EVLW. Results: Out of 150, 54 patients (36.0%) had EVLW. The mean lung score amongst our patients was 8.57 ± 6.0. The mean time for detection of EVLW was 1.43 ± 2.24 days. Lung score was low in 40 (26.67%) patients, moderate in 9 (6.00%) patients, and high in 5 (3.33%) patients. Incidence of weaning failure (p-value = 0.006), duration of weaning, mechanical ventilation, ICU stay (p-value < 0.0001 each), and overall mortality were significantly higher in patients with EVLW (p-value = 0.006). Conclusion: We conclude that a good proportion of critically ill patients have EVLW. Extravascular lung water significantly increases the duration of weaning, mechanical ventilation days, ICU stay, and overall mortality in critically ill patients. How to cite this article: Rajpal M, Talwar V, Krishna B, Mustafi SM. Assessment of Extravascular Lung Water Using Lung Ultrasound in Critically Ill Patients Admitted to Intensive Care Unit. Indian J Crit Care Med 2024;28(2):165-169.

3.
Crit Care ; 27(1): 201, 2023 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-37237287

RESUMO

BACKGROUND: A quantitative assessment of pulmonary edema is important because the clinical severity can range from mild impairment to life threatening. A quantitative surrogate measure, although invasive, for pulmonary edema is the extravascular lung water index (EVLWI) extracted from the transpulmonary thermodilution (TPTD). Severity of edema from chest X-rays, to date is based on the subjective classification of radiologists. In this work, we use machine learning to quantitatively predict the severity of pulmonary edema from chest radiography. METHODS: We retrospectively included 471 X-rays from 431 patients who underwent chest radiography and TPTD measurement within 24 h at our intensive care unit. The EVLWI extracted from the TPTD was used as a quantitative measure for pulmonary edema. We used a deep learning approach and binned the data into two, three, four and five classes increasing the resolution of the EVLWI prediction from the X-rays. RESULTS: The accuracy, area under the receiver operating characteristic curve (AUROC) and Mathews correlation coefficient (MCC) in the binary classification models (EVLWI < 15, ≥ 15) were 0.93 (accuracy), 0.98 (AUROC) and 0.86(MCC). In the three multiclass models, the accuracy ranged between 0.90 and 0.95, the AUROC between 0.97 and 0.99 and the MCC between 0.86 and 0.92. CONCLUSION: Deep learning can quantify pulmonary edema as measured by EVLWI with high accuracy.


Assuntos
Aprendizado Profundo , Edema Pulmonar , Humanos , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/etiologia , Raios X , Estudos Retrospectivos , Água Extravascular Pulmonar/diagnóstico por imagem , Radiografia , Termodiluição
4.
J Clin Monit Comput ; 37(2): 599-607, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36284041

RESUMO

In severe acute respiratory distress syndrome (ARDS), veno-venous extracorporeal membrane oxygenation (V-V ECMO) has been proposed as a therapeutic strategy to possibly reduce mortality. Transpulmonary thermodilution (TPTD) enables monitoring of the extravascular lung water index (EVLWI) and cardiac preload parameters such as intrathoracic blood volume index (ITBVI) in patients with ARDS, but it is not generally recommended during V-V ECMO. We hypothesized that the amount of extracorporeal blood flow (ECBF) influences the calculation of EVLWI and ITBVI due to recirculation of indicator, which affects the measurement of the mean transit time (MTt), the time between injection and passing of half the indicator, as well as downslope time (DSt), the exponential washout of the indicator. EVLWI and ITBVI were measured in 20 patients with severe ARDS managed with V-V ECMO at ECBF rates from 6 to 4 and 2 l/min with TPTD. MTt and DSt significantly decreased when ECBF was reduced, resulting in a decreased EVLWI (26.1 [22.8-33.8] ml/kg at 6 l/min ECBF vs 22.4 [15.3-31.6] ml/kg at 4 l/min ECBF, p < 0.001; and 13.2 [11.8-18.8] ml/kg at 2 l/min ECBF, p < 0.001) and increased ITBVI (840 [753-1062] ml/m2 at 6 l/min ECBF vs 886 [658-979] ml/m2 at 4 l/min ECBF, p < 0.001; and 955 [817-1140] ml/m2 at 2 l/min ECBF, p < 0.001). In patients with severe ARDS managed with V-V ECMO, increasing ECBF alters the thermodilution curve, resulting in unreliable measurements of EVLWI and ITBVI. German Clinical Trials Register (DRKS00021050). Registered 14/08/2018. https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00021050.


Assuntos
Oxigenação por Membrana Extracorpórea , Síndrome do Desconforto Respiratório , Humanos , Volume Sanguíneo , Água Extravascular Pulmonar , Estudos Prospectivos , Síndrome do Desconforto Respiratório/terapia , Termodiluição/métodos
5.
Int J Mol Sci ; 24(10)2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37240114

RESUMO

We compared two de-escalation strategies guided by either extravascular lung water or global end-diastolic volume-oriented algorithms in patients with sepsis and ARDS. Sixty patients with sepsis and ARDS were randomized to receive de-escalation fluid therapy, guided either by the extravascular lung water index (EVLWI, n = 30) or the global end-diastolic volume index (GEDVI, n = 30). In cases of GEDVI > 650 mL/m2 or EVLWI > 10 mL/kg, diuretics and/or controlled ultrafiltration were administered to achieve the cumulative 48-h fluid balance in the range of 0 to -3000 mL. During 48 h of goal-directed de-escalation therapy, we observed a decrease in the SOFA score (p < 0.05). Extravascular lung water decreased only in the EVLWI-oriented group (p < 0.001). In parallel, PaO2/FiO2 increased by 30% in the EVLWI group and by 15% in the GEDVI group (p < 0.05). The patients with direct ARDS demonstrated better responses to dehydration therapy concerning arterial oxygenation and lung fluid balance. In sepsis-induced ARDS, both fluid management strategies, based either on GEDVI or EVLWI, improved arterial oxygenation and attenuated organ dysfunction. The de-escalation therapy was more efficient for direct ARDS.


Assuntos
Síndrome do Desconforto Respiratório , Sepse , Humanos , Pulmão , Sepse/complicações , Sepse/terapia , Água Extravascular Pulmonar , Hidratação , Síndrome do Desconforto Respiratório/terapia
6.
Am J Respir Cell Mol Biol ; 66(2): e1-e14, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35103557

RESUMO

Advancements in methods, technology, and our understanding of the pathobiology of lung injury have created the need to update the definition of experimental acute lung injury (ALI). We queried 50 participants with expertise in ALI and acute respiratory distress syndrome using a Delphi method composed of a series of electronic surveys and a virtual workshop. We propose that ALI presents as a "multidimensional entity" characterized by four "domains" that reflect the key pathophysiologic features and underlying biology of human acute respiratory distress syndrome. These domains are 1) histological evidence of tissue injury, 2) alteration of the alveolar-capillary barrier, 3) presence of an inflammatory response, and 4) physiologic dysfunction. For each domain, we present "relevant measurements," defined as those proposed by at least 30% of respondents. We propose that experimental ALI encompasses a continuum of models ranging from those focusing on gaining specific mechanistic insights to those primarily concerned with preclinical testing of novel therapeutics or interventions. We suggest that mechanistic studies may justifiably focus on a single domain of lung injury, but models must document alterations of at least three of the four domains to qualify as "experimental ALI." Finally, we propose that a time criterion defining "acute" in ALI remains relevant, but the actual time may vary based on the specific model and the aspect of injury being modeled. The continuum concept of ALI increases the flexibility and applicability of the definition to multiple models while increasing the likelihood of translating preclinical findings to critically ill patients.


Assuntos
Lesão Pulmonar Aguda/patologia , Inflamação/fisiopatologia , Relatório de Pesquisa/tendências , Lesão Pulmonar Aguda/imunologia , Animais
7.
J Transl Med ; 20(1): 617, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-36564822

RESUMO

BACKGROUND: No direct approach assessing pulmonary vascular permeability exists in the current therapeutic strategy for patients with acute respiratory distress syndrome (ARDS). Transpulmonary thermodilution measures hemodynamic parameters such as pulmonary vascular permeability index and extravascular lung water, enabling clinicians to assess ARDS severity. The aim of this study is to explore a precise transpulmonary thermodilution-based criteria for quantifying the severity of lung injury using a clinically relevant septic-ARDS pig model. METHODS: Thirteen female pigs (weight: 31 ± 2 kg) were intubated, mechanically ventilated under anesthesia, and either assigned to septic shock-induced ARDS or control group. To confirm the development of ARDS, we performed computed tomography (CT) imaging in randomly selected animals. The pulmonary vascular permeability index, extravascular lung water, and other hemodynamic parameters were consecutively measured during the development of septic lung injury. Lung status was categorized as normal (partial pressure of oxygen/fraction of inspired oxygen ≥ 400), or injured at different degrees: pre-ARDS (300-400), mild-to-moderate ARDS (100-300), or severe ARDS (< 100). We also measured serum inflammatory cytokines and high mobility group box 1 levels during the experiment to explore the relationship of the pulmonary vascular permeability index with these inflammatory markers. RESULTS: Using CT image, we verified that animals subjected to ARDS presented an extent of consolidation in bilateral gravitationally dependent gradient that expands over time, with diffuse ground-glass opacification. Further, the post-mortem histopathological analysis for lung tissue identified the key features of diffuse alveolar damage in all animals subjected to ARDS. Both pulmonary vascular permeability index and extravascular lung water increased significantly, according to disease severity. Receiver operating characteristic analysis demonstrated that a cut-off value of 3.9 for the permeability index provided optimal sensitivity and specificity for predicting severe ARDS (area under the curve: 0.99, 95% confidence interval, 0.98-1.00; sensitivity = 100%, and specificity = 92.5%). The pulmonary vascular permeability index was superior in its diagnostic value than extravascular lung water. Furthermore, the pulmonary vascular permeability index was significantly associated with multiple parameters reflecting clinicopathological changes in animals with ARDS. CONCLUSION: The pulmonary vascular permeability index is an effective indicator to measure septic ARDS severity.


Assuntos
Lesão Pulmonar , Edema Pulmonar , Síndrome do Desconforto Respiratório , Choque Séptico , Infecção dos Ferimentos , Feminino , Suínos , Animais , Edema Pulmonar/complicações , Edema Pulmonar/diagnóstico , Termodiluição/métodos , Síndrome do Desconforto Respiratório/diagnóstico , Síndrome do Desconforto Respiratório/complicações , Pulmão/diagnóstico por imagem , Pulmão/irrigação sanguínea , Oxigênio
8.
J Intensive Care Med ; 37(1): 21-31, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33148110

RESUMO

INTRODUCTION: Visualization of B-lines via lung ultrasound provides a non-invasive estimation of pulmonary hydration. Extravascular lung water index (EVLWI) and pulmonary vascular permeability index (PVPI) assessed by transpulmonary thermodilution (TPTD) represent the most validated parameters of lung water and alveolocapillary permeability, but measurement is invasive and expensive. This study aimed to compare the correlations of B-lines scores from extensive 28-sector and simplified 4-sector chest scan with EVLWI and PVPI derived from TPTD in the setting of intensive care unit (primary endpoint). METHODS: We performed scoring of 28-sector and 4-sector B-Lines in 50 critically ill patients. TPTD was carried out with the PiCCO-2-device (Pulsion Medical Systems SE, Maquet Getinge Group). Median time exposure for ultrasound procedure was 12 minutes for 28-sector and 4 minutes for 4-sector scan. RESULTS: Primarily, we found close correlations of 28-sector as well as 4-sector B-Lines scores with EVLWI (R2 = 0.895 vs. R2 = 0.880) and PVPI (R2 = 0.760 vs. R2 = 0.742). Both B-lines scores showed high accuracy to identify patients with specific levels of EVLWI and PVPI. The extensive 28-sector B-lines score revealed a moderate advantage compared to simplified 4-sector scan in detecting a normal EVLWI ≤ 7 (28-sector scan: sensitivity = 81.8%, specificity = 94.9%, AUC = 0.939 versus 4-sector scan: sensitivity = 81.8%, specificity = 82.1%, AUC = 0.902). Both protocols were approximately equivalent in prediction of lung edema with EVLWI ≥ 10 (28-sector scan: sensitivity = 88.9%, specificity = 95.7%, AUC = 0.977 versus 4-sector scan: sensitivity = 81.5%, specificity = 91.3%, AUC = 0.958) or severe pulmonary edema with EVLWI ≥ 15 (28-sector scan: sensitivity = 91.7%, specificity = 97.4%, AUC = 0.995 versus 4-sector scan: sensitivity = 91.7%, specificity = 92.1%, AUC = 0.978). As secondary endpoints, our evaluations resulted in significant associations of 28-sector as well as simplified 4-sector B-Lines score with parameters of respiratory function. CONCLUSION: Both B-line protocols provide accurate non-invasive evaluation of lung water in critically ill patients. The 28-sector scan offers a marginal advantage in prediction of pulmonary edema, but needs substantially more time than 4-sector scan.


Assuntos
Água Extravascular Pulmonar , Edema Pulmonar , Estado Terminal , Água Extravascular Pulmonar/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Edema Pulmonar/diagnóstico por imagem , Termodiluição
9.
J Cardiothorac Vasc Anesth ; 36(8 Pt A): 2385-2392, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34895834

RESUMO

OBJECTIVE: Lung ultrasound (LUS) is a promising bedside modality for the estimation of extravascular lung water index (EVLWI), but has not been validated against objective measures in children. This study aimed to investigate the correlation of LUS B-line scoring with EVLWI, thresholds indicating elevated EVLWI, and its outcome following pediatric cardiac surgery. DESIGN: Prospective observational study. SETTING: Cardiothoracic surgical intensive care unit in a tertiary care teaching hospital. PARTICIPANTS: Children younger than 12 years undergoing elective complete surgical correction of cyanotic or acyanotic congenital heart disease (Aristotle score ≤9), excluding neonates, those weighing <3.5 kg, and those with thoracic deformities, pulmonary pathology, and hemodynamic instability. INTERVENTIONS: Extravascular lung water index measurement by transpulmonary thermodilution, along with concurrent LUS B-line and Chest-X ray (CXR) scoring. MEASUREMENTS AND MAIN RESULTS: LUS B-line score had a moderate correlation with EVLWI (Pearson's correlation coefficient 0.57; 95% CI 0.44-0.69). LUS B-line scores showed acceptable discrimination only for higher thresholds of EVLWI (sensitivity 82% and 79%, respectively, for EVLWI >20 mL/kg v sensitivity and specificity 57% and 80% for EVLWI >10 mL/kg). Age, body surface area, vasoactive-inotropic score (VIS), chest X-ray score, and EVLWI but not LUS B-line score were significant predictors for duration of mechanical ventilation in this cohort. CONCLUSIONS: LUS B-line scoring has limited utility in semiquantitative estimation of EVLWI at lower thresholds of EVLWI in pediatric cardiac surgical patients. It may have better discrimination and acceptable sensitivity and specificity at higher thresholds of EVLWI. Contrasting with multiple reports of clinical utility, these results call for wider evaluation of LUS and its clinical modifiers like age, pathology, and pretest probability in estimation of EVLWI.


Assuntos
Água Extravascular Pulmonar , Termodiluição , Criança , Água Extravascular Pulmonar/diagnóstico por imagem , Humanos , Recém-Nascido , Unidades de Terapia Intensiva , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Estudos Prospectivos , Termodiluição/métodos
10.
Artigo em Chinês | MEDLINE | ID: mdl-35255554

RESUMO

Objective: To study the effects on extravascular lung water of lung protective ventilation strategy applying on piglets with acute respiratory distress syndrome (ARDS) induced by paraquat (PQ) under pulse indicating continuous cardiac output (PiCCO) monitoring. Methods: The piglets models with ARDS induced by PQ were established in June 2020 and all of them were received mechanical ventilation and divided into three groups according to tidal volume (V(T)) : small V(T) group (6 ml/kg) , middle V(T) group (10 ml/kg) and large V(T) group (15 ml/kg) , there were 5 piglets in each group. The positive end expiratory pressure (PEEP) were all setup on 10 cmH(2)O. The indexes such as arterial blood gas analysis, oxygenation index (OI) , extravascular lung water index (ELWI) and pulmonary vascular permeability index (PVPI) were monitored at time of before the model was established (baseline) , time of the model was established (t(0)) and 2 h (t(2)) , 4 h (t(4)) , 6 h (t(6)) after mechanical ventilation. Lung tissue were punctured at time of baseline, t(0) and t(6) to be stained by Hematoxylin-eosin (HE) staining and pulmonary pathology were observed under light microscopy. Results: The heart rate (HR) , mean arterial pressure (MAP) and partial pressure of carbon dioxide (PaCO(2)) of all groups were higher than the base value while the pH values, partial pressure of oxygen (PaO(2)) and OI were lower than the base value when the models were established (P<0.05) . After mechanical ventilation, the HR and MAP values of all groups at t(2), t(4) and t(6) were lower than t(0) while the PaCO(2) of t(4) and t(6) were all higher than t(0), the differences were statistically significant (P<0.05) . The PaO(2) and OI of all groups showed a trend of rising at first and then decreasing after mechanical ventilation. The MAP, PaO(2), PaCO(2) and OI of the middle V(T) group and large V(T) group were apparently lower than that of the small V(T) group at t(2), t(4) and t(6) (P<0.05) . The ELWI and PVPI at t(0) of all groups were higher than that of baseline (P<0.05) . The ELWI of the small V(T) group at t(6) were lower than t(0) of the same group and t(6) of the middle V(T) group and large V(T) group (P<0.05) . HE staining showed congestion and edema of alveolar tissue, swelling of capillaries, exudation of red blood cells and widening of alveolar septum in piglets after successful modeling. And further widening of alveolar septum and rupture of alveolar septum could be seen in the lung tissues of each group at t(6), and the injury was the slightest in the small V(T) group. Conclusion: The lung protective ventilation strategy can alleviate the extravascular lung water and ARDS induced by PQ and improve oxygenation.


Assuntos
Água Extravascular Pulmonar , Síndrome do Desconforto Respiratório , Animais , Pulmão/fisiologia , Paraquat/toxicidade , Respiração Artificial/efeitos adversos , Síndrome do Desconforto Respiratório/induzido quimicamente , Suínos
11.
Am J Physiol Regul Integr Comp Physiol ; 319(5): R602-R609, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32936678

RESUMO

Patients with heart failure with preserved ejection fraction (HFpEF) experience symptoms of exertional dyspnea that may be related to lung fluid accumulation during exercise. A computed tomography (CT)-based method was used to measure exercise-induced changes in extravascular lung fluid content and thoracic blood volumes and to determine the effect of lung fluid on lung diffusing capacity for carbon monoxide (DLCO) in stable subjects with HFpEF and healthy controls. Nine subjects with HFpEF (age = 68 ± 8 yr; body mass index = 32.1 ± 2.6 kg/m2) and eight healthy controls (62 ± 9 yr, 23.8 ± 2.4 kg/m2) performed triplicate rebreathe DLCO/DLNO (lung diffusing capacity for nitric oxide) tests in a supine position at rest and duplicate measurements during two 5-min submaximal exercise stages (15W and 35W) and recovery. Subjects subsequently performed a 5-min exercise bout (35W) inside a CT scanner, and extravascular lung fluid content and thoracic blood volumes were quantified at rest and immediately following exercise from thoracic and contrast perfusion scans, respectively. Subjects with HFpEF had a higher lung fluid content at rest compared with controls (means ± SD, HFpEF: 14.4 ± 1.7%, control: 12.8 ± 1.7%, P = 0.043) and a higher lung fluid content following exercise (15.2 ± 2.0% vs. 12.6 ± 1.5%, P = 0.009). Higher lung fluid content was associated with a lower DLCO and alveolar-capillary membrane conductance (Dm) in subjects with HFpEF (DLCO: R = -0.57, P = 0.022, Dm: R = -0.61, P = 0.012) but not in controls. Pulmonary blood volume was not altered by exercise and was similar between groups. Submaximal exercise elicited a greater accumulation of lung fluid in subjects with HFpEF compared with in controls, and lung fluid content was negatively correlated with lung diffusing capacity and alveolar-capillary membrane conductance in subjects with HFpEF.


Assuntos
Exercício Físico , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Pulmão/patologia , Volume Sistólico/fisiologia , Tomografia Computadorizada por Raios X , Idoso , Volume Sanguíneo/fisiologia , Feminino , Insuficiência Cardíaca/classificação , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Capacidade de Difusão Pulmonar/fisiologia , Troca Gasosa Pulmonar/fisiologia
12.
J Intensive Care Med ; 35(11): 1356-1362, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31167585

RESUMO

Aggressive fluid resuscitation has become standard of care for hypotensive patients with sepsis. However, sepsis is a syndrome that occurs in patients with diverse underlying physiology and a one-size-fits-all approach to fluid administration seems misguided. To individualize fluid management, several methods to assess fluid responsiveness have been validated, but even in fluid responsive patients, fluid administration may still be harmful and lead to pulmonary edema. Hence, to individualize fluid management, in addition to fluid responsiveness, fluid tolerance needs to be assessed. This article examines whether lung ultrasound can be useful to detect excess extravascular lung water (EVLW) and thus assess fluid tolerance. The physiology of EVLW and the principles of lung ultrasound are briefly described. Articles examining the correlation between EVLW and lung ultrasound findings in various clinical settings are carefully reviewed. Overall, lung ultrasound has been found to be an excellent tool to detect EVLW, but large outcome studies investigating lung ultrasound-guided fluid management are still lacking.


Assuntos
Edema Pulmonar , Sepse , Água Extravascular Pulmonar/diagnóstico por imagem , Hidratação , Humanos , Pulmão/diagnóstico por imagem , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/terapia , Ultrassonografia
13.
Acta Anaesthesiol Scand ; 64(7): 953-960, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32236940

RESUMO

BACKGROUND: B-lines as typical artefacts of lung ultrasound are considered as surrogate measurement for extravascular lung water. However, B-lines develop in the sub-pleural space and do not allow assessment of the whole lung. Here, we present data from the first observational multi-centre study focusing on the correlation between a B-lines score and extravascular lung water in critically ill patients suffering from a variety of diseases. PATIENTS AND METHODS: In 184 adult patients, 443 measurements were obtained. B-lines were counted and expressed in a score which was compared to extravascular lung water, measured by single-indicator transpulmonary thermodilution. Appropriate correlation coefficients were calculated and receiver operating characteristics (ROC-) curves were plotted. RESULTS: Overall, B-lines score was correlated with body weight-indexed extravascular lung water characterized by r = .59. The subgroup analysis revealed a correlation coefficient in patients without an infection of r = .44, in those with a pulmonary infection of r = .75 and in those with an abdominal infection of r = .23, respectively. Using ROC-analysis the sensitivity and specificity of B-lines for detecting an increased extravascular lung water (>10 mL/kg) was 63% and 79%, respectively. In patients with a P/F ratio <200 mm Hg, sensitivity and specificity to predict an increased extravascular lung water was 71% and 93%, respectively. CONCLUSIONS: Assessment of B-lines does not accurately reflect actual extravascular lung water. In presence of an impaired oxygenation, B-lines may reliably indicate increased extravascular lung water as cause of the oxygenation disorders.


Assuntos
Água Extravascular Pulmonar/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estado Terminal , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Termodiluição , Adulto Jovem
14.
J Formos Med Assoc ; 119(5): 950-956, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31822372

RESUMO

BACKGROUND/PURPOSE: This study aimed to determine the potential effects of angiopoietin-2 (Ang-2), von Willebrand factor (vWF), and extravascular lung water index (EVLWI) on the risk of mortality in sepsis patients with concomitant acute respiratory distress syndrome (ARDS). METHODS: This retrospective study recruited 41 sepsis patients with concomitant ARDS from January 2015 to June 2018. Data of Ang-2 and vWF levels, EVLWI, and sequential organ failure assessment scores were collected at 0, 24, and 48 h after admission to the hospital. RESULTS: The length of intensive care unit stay (P = 0.041) and Acute Physiology and Chronic Health Evaluation-2 (APACHE II) score (P = 0.003) were associated with the risk of mortality. Furthermore, increased Ang-2 levels and EVLWI at 24 h and 48 h were associated with an increased risk of mortality. Moreover, the APACHE II score at hospital admission significantly predicted the risk of mortality (area under the curve [AUC], 0.834; 95% confidence interval [CI], 0.665-0.983). Finally, the models containing a combination of Ang-2 level and EVLWI at 24 h (AUC, 0.908; 95% CI, 0.774-0.996) and Ang-2 level and EVLWI at 48 h (AUC, 0.981; 95% CI, 0.817-1.000) had high diagnostic values for predicting risk of mortality. CONCLUSION: The study findings indicate that Ang-2 levels and EVLWI at 24 h and 48 h after admission are significantly associated with the risk of mortality.


Assuntos
Angiopoietina-2 , Água Extravascular Pulmonar , Síndrome do Desconforto Respiratório , Sepse , Fator de von Willebrand , Humanos , Prognóstico , Curva ROC , Estudos Retrospectivos , Fatores de Risco , Sepse/mortalidade
15.
Indian J Crit Care Med ; 24(6): 473-474, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32863642

RESUMO

How to cite this article: Choudhary N, Magoon R, Walian A, Kohli JK. Pulmonary Vascular Permeability Indices: Fine Prints of Lung Protection? Indian J Crit Care Med 2020;24(6):473-474.

16.
Crit Care ; 23(1): 288, 2019 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-31455421

RESUMO

BACKGROUND: This pilot study was designed to develop a fully automatic and quantitative scoring system of B-lines (QLUSS: quantitative lung ultrasound score) involving the pleural line and to compare it with previously described semi-quantitative scores in the measurement of extravascular lung water as determined by standard thermo-dilution. METHODS: This was a prospective observational study of 12 patients admitted in the intensive care unit with acute respiratory distress and each provided with 12 lung ultrasound (LUS) frames. Data collected from each patient consisted in five different scores, four semi-quantitative (nLUSS, cLUSS, qLUSS, %LUSS) and quantitative scores (QLUSS). The association between LUS scores and extravascular lung water (EVLW) was determined by simple linear regression (SLR) and robust linear regression (RLR) methods. A correlation analysis between the LUS scores was performed by using the Spearman rank test. Inter-observer variability was tested by computing intraclass correlation coefficient (ICC) in two-way models for agreement, basing on scores obtained by different raters blinded to patients' conditions and clinical history. RESULTS: In the SLR, QLUSS showed a stronger association with EVLW (R2 = 0.57) than cLUSS (R2 = 0.45) and nLUSS (R2 = 0.000), while a lower association than qLUSS (R2 = 0.85) and %LUSS (R2 = 0.72) occurred. By applying RLR, QLUSS showed an association for EVLW (R2 = 0.86) comparable to qLUSS (R2 = 0.85) and stronger than %LUSS (R2 = 0.72). QLUSS was significantly correlated with qLUSS (r = 0.772; p = 0.003) and %LUSS (r = 0.757; p = 0.005), but not with cLUSS (r = 0.561; p = 0.058) and nLUSS (r = 0.105; p = 0.744). Moreover, QLUSS showed the highest ICC (0.998; 95%CI from 0.996 to 0.999) among the LUS scores. CONCLUSIONS: This study demonstrates that computer-aided scoring of the pleural line percentage affected by B-lines has the potential to assess EVLW. QLUSS may have a significant impact, once validated with a larger dataset composed by multiple real-time frames. This approach has the potentials to be advantageous in terms of faster data analysis and applicability to large sets of data without increased costs. On the contrary, it is not useful in pleural effusion or consolidations.


Assuntos
Algoritmos , Pulmão/fisiopatologia , Projetos de Pesquisa/normas , Ultrassonografia/classificação , Adulto , Idoso , Feminino , Humanos , Unidades de Terapia Intensiva/organização & administração , Unidades de Terapia Intensiva/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Edema Pulmonar/diagnóstico , Edema Pulmonar/fisiopatologia , Projetos de Pesquisa/estatística & dados numéricos , Ultrassonografia/métodos
17.
Am J Respir Crit Care Med ; 197(9): 1128-1135, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29313715

RESUMO

RATIONALE: The effects of fluid administration during acute asthma exacerbation are likely unique in this patient population: highly negative inspiratory intrapleural pressure resulting from increased airway resistance may interact with excess fluid administration to favor the accumulation of extravascular lung water, leading to worse clinical outcomes. OBJECTIVES: Investigate how fluid balance influences clinical outcomes in children hospitalized for asthma exacerbation. METHODS: We analyzed the association between fluid overload and clinical outcomes in a retrospective cohort of children admitted to an urban children's hospital with acute asthma exacerbation. These findings were validated in two cohorts: a matched retrospective and a prospective observational cohort. Finally, ultrasound imaging was used to identify extravascular lung water and investigate the physiological basis for the inferential findings. MEASUREMENTS AND MAIN RESULTS: In the retrospective cohort, peak fluid overload [(fluid input - output)/weight] is associated with longer hospital length of stay, longer treatment duration, and increased risk of supplemental oxygen use (P values < 0.001). Similar results were obtained in the validation cohorts. There was a strong interaction between fluid balance and intrapleural pressure: the combination of positive fluid balance and highly negative inspiratory intrapleural pressures is associated with signs of increased extravascular lung water (P < 0.001), longer length of stay (P = 0.01), longer treatment duration (P = 0.03), and increased risk of supplemental oxygen use (P = 0.02). CONCLUSIONS: Excess volume administration leading to fluid overload in children with acute asthma exacerbation is associated with increased extravascular lung water and worse clinical outcomes.


Assuntos
Asma/fisiopatologia , Asma/terapia , Água Extravascular Pulmonar/fisiologia , Hidratação/métodos , Estado de Hidratação do Organismo/fisiologia , Adolescente , Boston , Criança , Estudos de Coortes , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
18.
BMC Anesthesiol ; 19(1): 93, 2019 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-31159739

RESUMO

BACKGROUND: Increased lung water and the resultant atelectasis are significant pulmonary complications after cardiopulmonary bypass (CPB) in children undergoing cardiac surgery; these complications are observed after CPB than after anaesthesia alone. Ultrafiltration has been shown to decrease total body water and postoperative blood loss and improve the alveolar to arterial oxygen gradient and pulmonary compliance. This study investigated whether conventional ultrafiltration during CPB in paediatric heart surgeries influences post-bypass extravascular lung water (EVLW) assessed by lung ultrasound (LUS). METHODS: This randomized controlled study included 60 patients with congenital heart disease (ASA II-III), aged 1 to 48 months, with a body weight > 3 kg. Conventional ultrafiltration targeting a haematocrit (HCT) level of 28% was performed on the ultrafiltration group, while the control group did not receive ultrafiltration. LUS scores were recorded at baseline and at the end of surgery. The PaO2/FiO2 ratio (arterial oxygen tension divided by the fraction of inspired oxygen), urine output, and haemodynamic parameters were also recorded. RESULTS: LUS scores were comparable between the two groups both at baseline (p = 0.92) and at the end of surgery (p = 0.95); however, within the same group, the scores at the end of surgery significantly differed from their baseline values in both the ultrafiltration (p = 0.01) and non-ultrafiltration groups (p = 0.02). The baseline PaO2/FiO2 ratio was comparable between both groups. at the end of surgery, The PaO2/FiO2 ratio increased in the ultrafiltration group compared to that in the non-ultrafiltration group, albeit insignificant (p = 0.16). no correlation between the PaO2/FiO2 ratio and LUS score was found at baseline (r = - 0.21, p = 0.31). On the other hand, post-surgical measurements were negatively correlated (r = - 0.41, p = 0.045). CONCLUSION: Conventional ultrafiltration did not alter the EVLW when assessed by LUS and oxygenation state. Similarly, ultrafiltration did not affect the urea and creatinine levels, intensive care unit (ICU) stays, ventilation days, or mortality. TRIAL REGISTRATION: Clinicaltrials.gov Identifier: NCT03146143 registered on 29-April-2017.


Assuntos
Procedimentos Cirúrgicos Cardíacos/tendências , Água Extravascular Pulmonar/fisiologia , Pulmão/diagnóstico por imagem , Pulmão/fisiologia , Ultrassonografia de Intervenção/tendências , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/tendências , Pré-Escolar , Feminino , Seguimentos , Humanos , Lactente , Masculino , Estudos Prospectivos , Ultrafiltração/métodos , Ultrafiltração/tendências
19.
J Ultrasound Med ; 38(6): 1537-1544, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30371951

RESUMO

OBJECTIVES: Fluid bolus therapy for the treatment of sepsis may lead to the accumulation of extravascular lung water (EVLW) and result in respiratory dysfunction. We aimed to assess changes in EVLW using lung ultrasound (US) in children with a presumptive clinical diagnosis of sepsis after fluid bolus therapy and correlate these changes with respiratory signs. METHODS: This work was a prospective observational study set in the emergency department of the Royal Children's Hospital. Children meeting international consensus criteria for sepsis receiving fluid bolus therapy were included. Respiratory signs were recorded, and lung US examinations were performed immediately before, 5 minutes after, and 60 minutes after fluid bolus therapy. A pediatric emergency physician blinded to the participants' identities and timing of US calculated an EVLW score from lung US. Results-Fifty fluid boluses were recorded in 41 children. The lung US score (range, 0-8) increased over the study period: median, 1 (interquartile range, 0-2) before fluid bolus therapy, 1 (interquartile range, 0-3) 5 minutes after fluid bolus therapy, and 3 (interquartile range, 1-4) 60 minutes after fluid bolus therapy. Respiratory effort, but not the respiratory rate or the presence of rales, increased over the study period and was correlated with the lung US score (ρ = 0.33; P = .02). CONCLUSIONS: Extravascular lung water as measured by lung US increased after fluid bolus therapy in septic children and was correlated with an increase in the respiratory distress score. The respiratory rate and the presence of rales did not change over the study period. The role of lung US for titrating fluid bolus therapy in sepsis warrants further investigation.


Assuntos
Água Extravascular Pulmonar/fisiologia , Hidratação/métodos , Pulmão/diagnóstico por imagem , Transtornos Respiratórios/complicações , Sepse/complicações , Ultrassonografia/métodos , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Lactente , Recém-Nascido , Pulmão/fisiopatologia , Masculino , Estudos Prospectivos , Transtornos Respiratórios/fisiopatologia , Sepse/fisiopatologia
20.
J Clin Monit Comput ; 33(1): 5-12, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-29680878

RESUMO

Extravascular lung water (index) (EVLW(I)) can be estimated using transpulmonary thermodilution (TPTD). Computed tomography (CT) with quantitative analysis of lung tissue density has been proposed to quantify pulmonary edema. We compared variables of pulmonary fluid status assessed using quantitative CT and TPTD in critically ill patients. In 21 intensive care unit patients, we performed TPTD measurements directly before and after chest CT. Based on the density data of segmented CT images we calculated the tissue volume (TV), tissue volume index (TVI), and the mean weighted index of voxel aqueous density (VMWaq). CT-derived TV, TVI, and VMWaq did not predict TPTD-derived EVLWI values ≥ 14 mL/kg. There was a significant moderate positive correlation between VMWaq and mean EVLWI (EVLWI before and after CT) (r = 0.45, p = 0.042) and EVLWI after CT (r = 0.49, p = 0.025) but not EVLWI before CT (r = 0.38, p = 0.086). There was no significant correlation between TV and EVLW before CT, EVLW after CT, or mean EVLW. There was no significant correlation between TVI and EVLWI before CT, EVLWI after CT, or mean EVLWI. CT-derived variables did not predict elevated TPTD-derived EVLWI values. In unselected critically ill patients, variables of pulmonary fluid status assessed using quantitative CT cannot be used to predict EVLWI.


Assuntos
Estado Terminal , Água Extravascular Pulmonar/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Edema Pulmonar/diagnóstico por imagem , Termodiluição/métodos , Idoso , Cuidados Críticos , Feminino , Hemodinâmica , Humanos , Unidades de Terapia Intensiva , Pulmão/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa