Sensors (Basel) ; 24(9)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38732959

RESUMO

For most patients admitted to a hospital, it is a requirement to continuously monitor their vital signs. Among these are the waveforms from ECG and the pulmonary arterial pulse. At present, there are several electronic devices that can measure the arterial pulse waveform. However, they can be affected by electromagnetic wave radiation, and the fabrication of electronic sensors is complicated and contributes to the e-waste, among other problems. In this paper, we propose an optical method to measure arterial pulse based on a Fabry-Perot interferometer composed of two mirrors. A pulse sensor formed by an acrylic cell with a thin membrane is used to gather the vasodilatation of the wrist, forming an air pulse that is enacted by means of a tube to a metallic cell containing a mirror that is glued to a thin silicone membrane. When the air pulse arrives, a displacement of the mirror takes place and produces a shift of the interference pattern fringes given by the Fabry-Perot. A detector samples the fringe intensity. With this method, an arterial pulse waveform is obtained. We characterize this optical device as a test of concept, and its application to measuring artery pulse is presented. The optical device is compared to other electronic devices.

2.
Sensors (Basel) ; 24(12)2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38931780

RESUMO

Conventional optical fiber temperature/strain sensors often have to make compromises between the resolution and the dynamic range. Here we present a new method that meets the measurement requirements for both high resolution and large dynamic range. A high-quality optical fiber Fabry-Perot Interferometer (FPI) constructed using a pair of chirped fiber Bragg gratings is employed as the sensor and a dual-mode direct spectrum interrogation method is proposed to identify the small drift of external temperature or strain. As a proof-of-concept illustration, a temperature resolution of 0.2 °C within 30-130 °C is demonstrated. For strain sensing, the resolution can be 10 µÎµ within 0-1000 µÎµ. The measurement resolution can be improved further by routinely increasing the reflectivity of the CFBG and the cavity length and the sensor can also be mass-produced. This new sensing schema not only resolves the conflict between the resolution and the dynamic range of fiber-optic temperature/strain sensors but can also be extended to other sensors and measurands.

3.
Sensors (Basel) ; 24(13)2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-39001159

RESUMO

This work explores the use of ZIF-8, a metal-organic framework (MOF) material, for its use in the optical detection of volatile organic compounds (VOCs) in Fabry-Pérot and surface plasmon resonance (SPR)-based sensors. The experiments have been carried out with ethanol (EtOH) and show response times as low as 30 s under VOC-saturated atmospheres, and the estimated limit of detection is below 4000 ppm for both sensor types. The selectivity towards other VOCs is relatively poor, although the dynamics of adsorption/desorption differ for each VOC and could be used for selectivity purposes. Furthermore, the hydrophobicity of ZIF-8 has been confirmed and the fabricated sensors are insensitive to this compound, which is a very attractive result for its practical use in gas sensing devices.

4.
Sensors (Basel) ; 23(2)2023 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-36679568

RESUMO

This study proposes a method for detecting small-length fluctuations for fiber-optic sensors (FOS). The method is based on a tracking tandem low-coherence interferometer and enables the ability to compensate for temperature and deformation drifts in FOS. As a result, the constant high sensitivity of FOS over a wide frequency range is guaranteed. Sensitivity to the level of 2 nm in the frequency range of 200 kHz has been demonstrated. The operation of the circuit is demonstrated on the example of the 2D location of acoustic signals using a correlation algorithm for signal processing, known as the time reversal method. It is shown that this system enables us to determine the place of the impact on the sample under the test with an accuracy of about 2 cm using a single sensor.


Assuntos
Acústica , Algoritmos , Tecnologia de Fibra Óptica , Processamento de Sinais Assistido por Computador , Temperatura
5.
Sensors (Basel) ; 23(18)2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37765743

RESUMO

Optical fiber Fabry-Pérot (FP) interferometer sensors have long been the focus of researchers in sensing applications because of their simple light path, low cost, compact size and convenient manufacturing methods. A miniature and highly sensitive optic fiber temperature sensor using an ultraviolet glue-filled FP cavity in a hollow capillary fiber is proposed. The sensor is fabricated by fusion splicing a single-mode fiber with a hollow capillary fiber, which is filled with ultraviolet glue to form a FP cavity. The sensor has a good linear response in the temperature testing and high-temperature sensitivity, which can be increased with the length of the FP cavity. The experimental results show that the temperature sensitivity reaches 1.174 nm/°C with a high linear response in the range of 30-60 °C. In addition, this sensor is insensitive to pressure and can be highly suitable for real-time water temperature monitoring for ocean research. The proposed ultraviolet glue-filled structure has the advantages of easy fabrication, high-temperature sensitivity, low cost and an arbitrary length of capillary, which has broad application prospects for marine survey technology, biological diagnostics and environmental monitoring.

6.
Sensors (Basel) ; 23(18)2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37765811

RESUMO

This paper reports a fiber in-line Fabry-Perot interferometer (FPI) fabricated in a no-core fiber using the direct femtosecond laser writing technique for high-temperature sensing applications. Two in-line reflectors are directly inscribed in a no-core fiber to construct a low-finesse FPI. Fringe visibility greater than 10 dB is obtained from the reflection spectra of the fabricated no-core fiber FPIs. Temperature responses of a prototype no-core fiber FPI are characterized up to 1000 °C. The proposed configuration is compact and easy to fabricate, making it attractive for sensing applications in high-temperature harsh environments.

7.
Sensors (Basel) ; 23(4)2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36850505

RESUMO

This paper describes a Fabry-Pérot sensor-based measuring system for measuring fluid composition in demanding industrial applications. The design of the sensor is based on a two-parametric sensor, which enables the simultaneous measurement of temperature and refractive index (RI). The system was tested under real industrial conditions, and enables temperature-compensated online measurement of emulsion concentration with a high resolution of 0.03 Brix. The measuring system was equipped with filtering of the emulsion and automatic cleaning of the sensor, which proved to be essential for successful implementation of a fiber optic RI sensor in machining emulsion monitoring applications.

8.
Sensors (Basel) ; 23(8)2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-37112484

RESUMO

In this work, we proposed a sensitivity-enhanced temperature sensor, a compact harmonic Vernier sensor based on an in-fiber Fabry-Perot Interferometer (FPI), with three reflective interfaces for the measurement of gas temperature and pressure. FPI consists of air and silica cavities formulated by single-mode optical fiber (SMF) and several short hollow core fiber segments. One of the cavity lengths is deliberately made larger to excite several harmonics of the Vernier effect that have different sensitivity magnifications to the gas pressure and temperature. The spectral curve could be demodulated using a digital bandpass filter to extract the interference spectrum according to the spatial frequencies of resonance cavities. The findings indicate that the material and structural properties of the resonance cavities have an impact on the respective temperature sensitivity and pressure sensitivity. The measured pressure sensitivity and temperature sensitivity of the proposed sensor are 114 nm/MPa and 176 pm/°C, respectively. Therefore, the proposed sensor combines ease of fabrication and high sensitivity, making it great potential for practical sensing measurements.

9.
Sensors (Basel) ; 23(5)2023 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-36905002

RESUMO

In this paper, fiber sensor based on Vernier effect for simultaneous measurement of relative humidity (RH) and temperature is proposed. The sensor is fabricated by coating two kinds of ultraviolet (UV) glue with different refractive indexes (RI) and thicknesses on the end face of a fiber patch cord. The thicknesses of two films are controlled to generate the Vernier effect. The inner film is formed by a cured lower-RI UV glue. The exterior film is formed by a cured higher-RI UV glue, of which thickness is much thinner than the inner film. Through the analysis of the Fast Fourier Transform (FFT) of the reflective spectrum, the Vernier effect is formed by the inner lower-RI polymer cavity and the cavity composed of both polymer films. By calibrating the RH and temperature response of two peaks on the envelope of the reflection spectrum, simultaneous measurements of RH and temperature are realized by solving a set of quadratic equations. Experimental results show that the highest RH and temperature sensitivities of the sensor are 387.3 pm/%RH (in 20%RH to 90%RH) and -533.0 pm/°C (in 15 °C to 40 °C), respectively. The sensor has merits of low cost, simple fabrication, and high sensitivity, which makes it very attractive for applications that need to simultaneously monitor these two parameters.

10.
Sensors (Basel) ; 23(7)2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-37050634

RESUMO

To achieve high-quality voice communication technology without noise interference in flammable, explosive and strong electromagnetic environments, the speech enhancement technology of a fiber-optic external Fabry-Perot interferometric (EFPI) acoustic sensor based on deep learning is studied in this paper. The combination of a complex-valued convolutional neural network and a long short-term memory (CV-CNN-LSTM) model is proposed for speech enhancement in the EFPI acoustic sensing system. Moreover, the 3 × 3 coupler algorithm is used to demodulate voice signals. Then, the short-time Fourier transform (STFT) spectrogram features of voice signals are divided into a training set and a test set. The training set is input into the established CV-CNN-LSTM model for model training, and the test set is input into the trained model for testing. The experimental findings reveal that the proposed CV-CNN-LSTM model demonstrates exceptional speech enhancement performance, boasting an average Perceptual Evaluation of Speech Quality (PESQ) score of 3.148. In comparison to the CV-CNN and CV-LSTM models, this innovative model achieves a remarkable PESQ score improvement of 9.7% and 11.4%, respectively. Furthermore, the average Short-Time Objective Intelligibility (STOI) score witnesses significant enhancements of 4.04 and 2.83 when contrasted with the CV-CNN and CV-LSTM models, respectively.

11.
Sensors (Basel) ; 23(6)2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36991608

RESUMO

We systematically designed dual polymer Fabry-Perrot interferometer (DPFPI) sensors, which were used to achieve highly sensitive temperature sensors. The designed and fabricated DPFPI has a dual polymer coating layer consisting of thermosensitive poly (methyl methacrylate) (PMMA) and polycarbonate (PC) polymers. Four different DPFPI sensors were developed, in which different coating optical path lengths and the resultant optical properties were generated by the Vernier effect, changing the sequence of the applied polymers and varying the concentration of the coating solutions. The experimental results confirmed that the PC_PMMA_S1 DPFPI sensor delivered a temperature sensitivity of 1238.7 pm °C-1, which was approximately 4.4- and 1.4-fold higher than that of the PMMA and PMMA_PC_S1-coated sensor, respectively. Thus, the results reveal that the coating sequence, the compact thickness of the dual polymer layers, and the resultant optical parameters are accountable for achieving sensors with high sensitivity. In the PC_ PMMA-coated sensor, the PMMA outer layer has comparatively better optical properties than the PC, which might produce synergistic effects that create a large wavelength shift with small temperature deviations. Therefore, it is considered that the extensive results with the PC_PMMA_S1 DPFPI sensor validate the efficacy, repeatability, reliability, quick reaction, feasibility, and precision of the temperature readings.

12.
Sensors (Basel) ; 23(6)2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36991908

RESUMO

In this paper, an optical fiber Fabry-Pérot (FP) microfluidic sensor based on the capillary fiber (CF) and side illumination method is designed. The hybrid FP cavity (HFP) is naturally formed by the inner air hole and silica wall of CF which is side illuminated by another single mode fiber (SMF). The CF acts as a naturally microfluidic channel, which can be served as a potential microfluidic solution concentration sensor. Moreover, the FP cavity formed by silica wall is insensitive to ambient solution refractive index but sensitive to the temperature. Thus, the HFP sensor can simultaneously measure microfluidic refractive index (RI) and temperature by cross-sensitivity matrix method. Three sensors with different inner air hole diameters were selected to fabricate and characterize the sensing performance. The interference spectra corresponding to each cavity length can be separated from each amplitude peak in the FFT spectra with a proper bandpass filter. Experimental results indicate that the proposed sensor with excellent sensing performance of temperature compensation is low-cost and easy to build, which is suitable for in situ monitoring and high-precision sensing of drug concentration and the optical constants of micro-specimens in the biomedical and biochemical fields.

13.
Sensors (Basel) ; 23(6)2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36992012

RESUMO

We report a high-resolution fiber optic temperature sensor system based on an air-filled Fabry-Pérot (FP) cavity, whose spectral fringes shift due to a precise pressure variation in the cavity. The absolute temperature can be deduced from the spectral shift and the pressure variation. For fabrication, a fused-silica tube is spliced with a single-mode fiber at one end and a side-hole fiber at the other to form the FP cavity. The pressure in the cavity can be changed by passing air through the side-hole fiber, causing the spectral shift. We analyzed the effect of sensor wavelength resolution and pressure fluctuation on the temperature measurement resolution. A computer-controlled pressure system and sensor interrogation system were developed with miniaturized instruments for the system operation. Experimental results show that the sensor had a high wavelength resolution (<0.2 pm) with minimal pressure fluctuation (~0.015 kPa), resulting in high-resolution (±0.32 ℃) temperature measurement. It shows good stability from the thermal cycle testing with the maximum testing temperature reaching 800 ℃.

14.
Sensors (Basel) ; 23(21)2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37960484

RESUMO

The finite element method (FEM) was used to investigate the optical-mechanical behavior of a Fabry-Perot Interferometer (FPI) composed of a capillary segment spliced between two sections of standard optical fiber. The developed FEM model was validated by comparing it with theory and with previously published experimental data. The model was then used to show that the absolute strain on the host substrate is usually smaller than the strain measurement obtained with the sensor. Finally, the FEM model was used to propose a cavity geometry that can be produced with repeatability and that yields the correct absolute strain experienced by the host substrate, without requiring previous strain calibration.

15.
Sensors (Basel) ; 23(14)2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37514786

RESUMO

This paper describes the use of an optical instrument, the Fabry-Perot interferometer, adapted to measure very low pressures. The interferometer consists of two high-reflectance flat mirrors placed one in front of another. In addition, a metallic chamber contains air or a gas. In one of the faces of the chamber, a flexible thin silicone membrane is attached and, over it, one of the mirrors is glued. The other mirror rests in a fixed mechanical mounting. Light crosses both mirrors and, when it leaves them, forms an interference pattern consisting of concentric circular fringes. When the pressure is increased/decreased within the chamber, a displacement of the fringes is observed due to the movement of the glued mirror. By measuring the fringe displacement and knowing the pressure, a calibration plot can be made. Minimum pressure measurements of about tens of Pascals were achieved.

16.
Sensors (Basel) ; 23(11)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37299988

RESUMO

Carbon-fiber-reinforced polymer (CFRP) is a type of composite material with many superior performances, such as high tensile strength, light weight, corrosion resistance, good fatigue, and creep performance. As a result, CFRP cables have great potential to replace steel cables in prestressed concrete structures. However, the technology to monitor the stress state in real-time throughout the entire life cycle is very important in the application of CFRP cables. Therefore, an optical-electrical co-sensing CFRP cable (OECSCFRP cable) was designed and manufactured in this paper. Firstly, a brief description is outlined for the production technology of the CFRP-DOFS bar, CFRP-CCFPI bar, and CFRP cable anchorage technology. Subsequently, the sensing and mechanical properties of the OECS-CFRP cable were characterized by serious experiments. Finally, the OECS-CFRP cable was used for the prestress monitoring of an unbonded prestressed RC beam to verify the feasibility of the actual structure. The results show that the main static performance indexes of DOFS and CCFPI meet the requirements of civil engineering. In the loading test of the prestressed beam, the OECS-CFRP cable can effectively monitor the cable force and the midspan defection of the beam so as to obtain the stiffness degradation of the prestressed beam under different loads.


Assuntos
Polímeros Responsivos a Estímulos , Fibra de Carbono , Polímeros , Comércio
17.
Sensors (Basel) ; 23(7)2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-37050498

RESUMO

In this paper, a review of multicore fiber interferometric sensors is given. Due to the specificity of fiber structure, i.e., multiple cores integrated into only one fiber cladding, multicore fiber (MCF) interferometric sensors exhibit many desirable characteristics compared with traditional fiber interferometric sensors based on single-core fibers, such as structural and functional diversity, high integration, space-division multiplexing capacity, etc. Thanks to the unique advantages, e.g., simple fabrication, compact size, and good robustness, MCF interferometric sensors have been developed to measure various physical and chemical parameters such as temperature, strain, curvature, refractive index, vibration, flow, torsion, etc., among which the extraordinary vector-bending sensing has also been extensively studied by making use of the differential responses between different cores of MCFs. In this paper, different types of MCF interferometric sensors and recent developments are comprehensively reviewed. The basic configurations and operating principles are introduced for each interferometric structure, and, eventually, the performances of various MCF interferometric sensors for different applications are compared, including curvature sensing, vibration sensing, temperature sensing, and refractive index sensing.

18.
Eur Biophys J ; 51(2): 185-191, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35018482

RESUMO

High-throughput single-cell analysis based on physical properties (such as morphology or mechanics) is emerging as a powerful tool to inform clinical research, with a great potential for translation towards diagnosis. Here we present a novel microfluidic approach adopting acoustic waves to manipulate and mechanically stimulate single cells, and interferometry to track changes in the morphology and measure size, deformability, and refractive index of non-adherent cells. The method is based on the integration within the acoustofluidic channel of a low-finesse Fabry-Perot resonator, providing very high sensitivity and a speed potentially suitable to obtain the high-throughput necessary to handle the variability stemming from the biological diversity of single cells. The proposed approach is applied to a set of different samples: reference polystyrene beads, algae and yeast. The results demonstrate the capability of the acoustofluidic interferometric device to detect and quantify optomechanical properties of single cells with a throughput suitable to address label-free single-cell clinical analysis.


Assuntos
Acústica , Som , Interferometria , Microfluídica , Poliestirenos
19.
Sensors (Basel) ; 22(14)2022 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-35891006

RESUMO

A compact fiber ultrasound-sensing device comprising a commercially available Barium Titanate (BaTiO3) glass microsphere coupled to an open cavity off-core Fabry-Perot interferometer (FPI) fiber sensor is proposed and demonstrated. The open cavity is fabricated through splicing two segments of a single mode fiber (SMF-28) at lateral offsets. The lateral offset is matched to the radius of the microsphere to maximize their coupling and allow for an increased sensing response. Furthermore, the microsphere can be moved along the open-air cavity to allow for tuning of the reflection spectrum. The multiple passes of the FPI enabled by the high refractive index microsphere results in a 40 dB enhancement of finesse and achieves broadband ultrasound sensing from 0.1-45.6 MHz driven via a piezoelectric transducer (PZT) centered at 3.7 MHz. The goal is to achieve frequency detection in the MHz range using a repeatable, cost effective, and easy to fabricate FPI sensor design.

20.
Sensors (Basel) ; 22(17)2022 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-36080789

RESUMO

This work presents a novel methodology to implement a fuzzy inference system (FIS) to overcome the measurement ambiguity that is typically observed in interferometric sensors. This ambiguity occurs when the measurand is determined by tracing the wavelength position of a peak or dip of a spectral fringe. Consequently, the sensor measurement range is typically limited to the equivalent of 1 free spectral range (FSR). Here, it is demonstrated that by using the proposed methodology, the measurement range of this type of sensor can be widened several times by overcoming the ambiguity over some FSR periods. Furthermore, in order to support the viability of the methodology, it was applied to a couple of temperature interferometric sensors. Finally, experimental results demonstrated that it was possible to quintuple the measurement range of one of the tested sensors with a mean absolute error of MAE = 0.0045 °C, while for the second sensor, the measurement range was doubled with an MAE = 0.0073 °C.