BACKGROUND: Gartland Type III supracondylar humerus fractures (SCHFs) are commonly treated using closed reduction followed by percutaneous pin fixation. However, conversion to open reduction may be necessary if closed reduction fails. This study aimed to identify risk factors associated with failed closed reduction and provide a theoretical basis for clinical decision-making in the treatment of Gartland Type III fractures. METHODS: A retrospective analysis was conducted on children with Gartland Type III SCHF who underwent surgical treatment between April 2017 and June 2018. Based on whether or not the closed reduction was successful, patients were split into the open reduction group and the closed reduction group. Within the closed reduction group, subgroup analysis based on surgery duration was carried out. Data were collected from medical records and X-ray images. Univariate and multivariate regression analyses were utilized to evaluate the relationship between variables and failed closed reduction. RESULTS: The study included 36 patients in the open reduction group and 135 patients in the closed reduction group. Multivariate analysis revealed that the presence of angle (P = .024, OR = 3.199), rotation (P = .000, OR = 6.359), skin creases (P = .013, OR = 4.077), anterior-posterior displacement ratio (P = .011, OR = 4.337), fracture angle in the anteroposterior view (P = .014, OR = 0.939), and fracture distal displacement direction (P = .002, OR = 5.384) were independent risk factors for failed closed reduction. Subgroup analysis showed that fracture distal displacement direction (P = .013), skin folds (P = .013), lateral displacement ratio (P = .016), and anterior-posterior displacement value (P = .005) significantly influenced the duration of closed reduction surgery. CONCLUSION: The presence of sharp angle or rotation at the fracture ends, skin folds on the anterior elbow, minor anterior-posterior displacement of the fracture, higher medial inclination of the fracture plane, and distal fracture displacement toward the radial side are independent risk factors for failed closed reduction in pediatric Gartland Type III SCHF.

2.
J Foot Ankle Surg ; 63(2): 291-294, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38103721

RESUMO

There has been a paradigm shift towards fixing the posterior malleolus in trimalleolar ankle fractures. This study evaluated whether a surgeon's preference to intraoperatively flip or not flip patients from prone to supine for medial malleolar fixation following repair of fibular and posterior malleoli impacted surgical outcomes. A retrospective patient cohort treated at a large urban academic center and level 1 trauma center was reviewed to identify all operative trimalleolar ankle fractures initially positioned prone. One hundred and forty-seven patients with mean 12-month follow-up were included and divided based on positioning for medial malleolar fixation, prone or supine (following closure, flip and re-prep, and drape). Data was collected on patient demographics, injury mechanism, perioperative variables, and complication rates. Postoperative reduction films were reviewed by orthopedic traumatologists to grade the accuracy of anatomic fracture reduction. Overall, 74 (50.3%) had the medial malleolus fixed prone, while 73 (49.7%) were flipped and fixed supine. No differences in demographics, injury details, and fracture type existed between the groups. The supine group had a higher rate of initial external fixation (p = .047), longer operative time in minutes (p < .001), and a higher use of plate and screw constructs for medial malleolar fixation (p = .019). There were no differences in clinical and radiographic outcomes and complication rates. This study demonstrated that intraoperative change in positioning for improved medial malleolar visualization in trimalleolar ankle fractures results in longer operative times but similar radiographic and clinical results. The decision of operative position should be based on surgeon comfort.


Assuntos
Fraturas do Tornozelo , Humanos , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Articulação do Tornozelo/cirurgia , Tornozelo , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-38376587

RESUMO

PURPOSE: Hemipelvis reduction in the setting of AO/OTA 61-C1.2 (APC3) pelvic injuries can be challenging. A common strategy is to provisionally reduce or fix the anterior ring prior to definitive fixation of the posterior ring. In this scenario, it is difficult to assess whether residual sacroiliac joint (SIJ) widening is due to hemipelvis flexion/extension or lateral displacement. This simulation sought to identify a radiographic marker for posterior ilium flexion or extension malreduction in the setting of a reduced anterior ring. METHODS: Symphyseal and both anterior and posterior SIJ ligaments were cut in 8 cadaveric pelvis. The symphysis was reduced and wired. One centimeter of posterior flexion or extension at the SIJ was created to mimic the clinical scenario of hemipelvis flexion or extension malreduction, and a lateral compressive force was applied. SIJ widening and the direction of anterior or posterior ileal displacement relative to the contralateral joint were assessed via inlet views. SIJ widening and the direction of cranial or caudal ileal displacement were assessed using outlet views. Comparisons between flexion and extension models used Fisher's exact test. RESULTS: On outlet views, all flexed hemipelvis demonstrated caudal ileal translation at the superior SIJ, in contrast to all extended hemipelvis demonstrated cranial translation (p < 0.0005); the scenarios were easily distinguishable. Conversely, inlet imaging was unable to identify the direction of malreduction. Flexion/extension scenarios resulted in similar amounts of SIJ widening. CONCLUSION: Residual flexion and extension hemipelvis malreductions in APC3 injuries after provisional anterior fixation can be differentiated by the direction of ileal displacement at the superior SIJ on the outlet view.

4.
BMC Musculoskelet Disord ; 24(1): 941, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38053090

RESUMO

BACKGROUND: Cortical buttress are important factors for postoperative stable reconstruction of per/inter-trochanteric fractures. The study aimed to measure the remnant axial cortical length (RACL) of the proximal circumference of the femur, and to determine which part of the RACL can be used reliably to postoperatively sustain the head-neck fragment as a cortical support pattern. METHODS: Eighty patients with trochanteric hip fractures admitted from January 2015 to January 2016 were included in a retrospective study. Their pre-operative computed tomography (CT) images were used to form 3D-CT reconstructions via Mimics software. After simulated rotation and movement for fracture reduction, the RACL, its three component parts-namely, the remnant anterior cortex (RAC), remnant lateral cortex (RLC), and remnant posterior cortex (RPC) -the γ angle between the anterior and posterior cortex, and the Hsu's lateral wall thickness (LWT) were evaluated. RESULTS: Patients with an A1 fracture (21/80) had a longer RACL (88.8 ± 15.8 mm) than those with an A2 fracture (60.0 ± 11.9 mm; P < 0.01). The RAC, RLC, and RPC of the RACL in A1 fractures were also significantly longer than those in A2 fractures (P < 0.001). However, the most significant difference among the three components of the RACL was in the RPC, which was 27.3 ± 7.8 mm in A1 fractures and 9.2 ± 6.6 mm in A2 fractures. In addition, the coefficient of variation of the RAC was only 20.0%, while that of the RPC was 75.5%. The average γ angle in A1 fractures was 16.2 ± 13.1°, which was significantly smaller than that in A2 fractures, which was 40.3 ± 14.5° (P < 0.001). There was a significant statistical difference in the LWT between A1 and A2 fractures (P < 0.001). There were significant differences in the RACL, RAC, RLC, RPC, γ angle, and LWT among the five subtypes (P < 0.001). CONCLUSIONS: The RAC is relatively stable in pertrochanteric fractures. Fracture reduction through a RAC buttress may help to enhance the postoperative stable reconstruction of per/inter-trochanteric fractures and make possible good mechanical support for fracture healing.


Assuntos
Fraturas do Fêmur , Fraturas do Quadril , Humanos , Estudos Retrospectivos , Fraturas do Fêmur/cirurgia , Fêmur/cirurgia , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Tomografia Computadorizada por Raios X/métodos
5.
BMC Musculoskelet Disord ; 24(1): 694, 2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37649090

RESUMO

OBJECTIVES: The methods of reduction of depressed posterolateral fragments in tibial plateau fracture through anterolateral approaches remain controversial. This paper aimed to compare the intraarticular osteotomy technique and the "window" osteotomy technique for the reduction of depressed posterolateral fragments through anterolateral approach. METHOD: From January 2015 to January 2022, we retrospectively reviewed the data on patients with tibial plateau fracture involving depressed posterolateral fragments treated with the intraarticular osteotomy or the "window" osteotomy. 40 patients underwent the intraarticular osteotomy were divided into group A, while 36 patients underwent the "window" osteotomy were divided into group B. The operative time, bone grafting volume, fracture healing time, complication, reduction quality and postoperative functional results were compared between the two groups. RESULTS: The average follow-up duration was 16.6 ± 3.7 months. The average bone grafting volume for all patients in group B was essential larger than group A (p = 0.001). Compared to group B, patients in groups A had significantly shorter fracture healing time (p = 0.011). The depth of depressed articular surface, PSA and the radiographic evaluation at 2 days and 6 months after surgery in group A were significantly lower than group B (p<0.05). Based on the HSS knee-rating score, no significant difference in function results was found between the two groups (p>0.05). No significant difference was found in operation time and blood loss between the two groups (p>0.05). CONCLUSION: The intraarticular osteotomy could obtain satisfactory clinical results in tibial plateau fracture involving posterolateral fragments.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Humanos , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Transplante Ósseo , Osteotomia
6.
J Oral Rehabil ; 50(3): 194-202, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36533877

RESUMO

BACKGROUND: Oral functioning and rehabilitation in patients after condylar trauma can be measured by objective functional outcomes and patient-reported outcomes. The similarities or differences between these outcomes may contribute to the decision if open treatment (OT) or closed treatment (CT) will obtain the most advantageous results. OBJECTIVES: The aim of this study was to compare OT versus CT for unilateral condylar mandibular neck or base fractures in a two-centre controlled clinical trial by objective functional outcomes and patient-reported outcomes measured at 6 weeks and 6 months follow-up. Additionally, these outcomes were compared within each group. METHODS: Patients were enrolled between January 2017 and November 2019. In one centre, patients received OT by extra-oral open reduction and internal fixation. In another centre, patients received CT by maxillomandibular fixation. Objective measurements included the mixing ability test (MAT) and mandibular active range of motion (ROM). Patient-reported outcomes included the mandibular function impairment questionnaire (MFIQ) and visual analogue scale (VAS) for pain. Independent t-tests and Mann-Whitney U-tests were used to determine differences between the treatment groups at 6 weeks and 6 months follow-up. Paired t-tests and Wilcoxon signed rank tests were used to determine differences within each group. RESULTS: Thirty-three patients were enrolled. No differences were found between the groups treated with OT or CT for MAT, ROM, MFIQ and VAS. Both groups showed functional improvement. CONCLUSION: Good objective functional outcomes and patient-reported outcomes were achieved with both OT and CT in patients with unilateral condylar mandibular neck or base fractures.


Assuntos
Fraturas Mandibulares , Humanos , Fixação Interna de Fraturas/métodos , Mandíbula , Côndilo Mandibular , Fraturas Mandibulares/diagnóstico por imagem , Fraturas Mandibulares/cirurgia , Resultado do Tratamento
7.
Dent Traumatol ; 39(5): 448-454, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37140473

RESUMO

PURPOSE: Intraoperative stabilisation of bony fragments with maxillo-mandibular fixation (MMF) is an essential step in the surgical treatment of mandibular fractures that are treated with open reduction and internal fixation (ORIF). The MMF can be performed with or without wire-based methods, rigid or manual MMF, respectively. The aim of this study was to compare the use of manual versus rigid MMF, in terms of occlusal outcomes and infective complications. MATERIALS AND METHODS: This multi-centric prospective study involved 12 European maxillofacial centres and included adult patients (age ≥16 years) with mandibular fractures treated with ORIF. The following data were collected: age, gender, pre-trauma dental status (dentate or partially dentate), cause of injury, fracture site, associated facial fractures, surgical approach, modality of intraoperative MMF (manual or rigid), outcome (minor/major malocclusions and infective complications) and revision surgeries. The main outcome was malocclusion at 6 weeks after surgery. RESULTS: Between May 1, 2021 and April 30, 2022, 319 patients-257 males and 62 females (median age, 28 years)-with mandibular fractures (185 single, 116 double and 18 triple fractures) were hospitalised and treated with ORIF. Intraoperative MMF was performed manually on 112 (35%) patients and with rigid MMF on 207 (65%) patients. The study variables did not differ significantly between the two groups, except for age. Minor occlusion disturbances were observed in 4 (3.6%) patients in the manual MMF group and in 10 (4.8%) patients in the rigid MMF group (p > .05). In the rigid MMF group, only one case of major malocclusion required a revision surgery. Infective complications involved 3.6% and 5.8% of patients in the manual and rigid MMF group, respectively (p > .05). CONCLUSION: Intraoperative MMF was performed manually in nearly one third of the patients, with wide variability among the centres and no difference observed in terms of number, site and displacement of fractures. No significant difference was found in terms of postoperative malocclusion among patients treated with manual or rigid MMF. This suggests that both techniques were equally effective in providing intraoperative MMF.


Assuntos
Má Oclusão , Fraturas Mandibulares , Adulto , Masculino , Feminino , Humanos , Adolescente , Fraturas Mandibulares/etiologia , Estudos Prospectivos , Fixação Interna de Fraturas/métodos , Mandíbula/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
8.
BMC Musculoskelet Disord ; 23(1): 175, 2022 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-35209887

RESUMO

BACKGROUND: Maintaining anteromedial cortical support is essential for controlling sliding and decreasing postoperative implant-related complications. However, adequate fracture reduction with cortical support in immediate postoperative fluoroscopy is not invariable in postoperative follow-ups. This study was conducted to investigate the risk factors leading to anteromedial cortical support failure in follow up for pertrochanteric femur fractures treated with cephalomedullary nails. METHODS: This retrospective study enrolled 159 patients with pertrochanteric fractures (AO/OTA- 31A1 and 31A2) that fixed with cephalomedullary nails. All patients were evaluated as adequate fracture reduction in immediate postoperative fluoroscopy before leaving the operation theater. The patients were separated into two groups based on the condition of the anteromedial cortex in the postoperative 3D CT with full-range observation: those with calcar support maintained in Group 1 and those with calcar support lost in Group 2. Demographic information, fracture classification, TAD (tip-apex distance), Cal-TAD, Parker ratio, NSA (neck-shaft angle), reduction quality score, and calcar fracture gapping were collected and compared. Logistic regression analysis was conducted to explore the risk factors leading to anteromedial cortex change. RESULTS: Anteromedial cortical support failure was noted in 46 cases (29%). There was no significant difference between the two groups concerning age, sex, side injury, TAD, Cal-TAD, Parker ratio, or NSA. There was a significant difference in the AO/OTA fracture classification in univariate analysis but no difference in the multivariable analysis. The reduction quality score, calcar fracture gapping in the AP (anteroposterior), and lateral views were significantly associated with anteromedial cortical support failure in follow-up after cephalomedullary nailing in the multivariable analysis. The threshold value of calcar fracture gapping for the risk of loss was 4.2 mm in the AP and 3.8 mm in the lateral fluoroscopies. Mechanical complications (lateral sliding and varus) were frequently observed in the negative anteromedial cortical support group. CONCLUSIONS: Good reduction quality was a protective factor, and larger calcar fracture gapping in the AP and lateral views were risk factors leading to the postoperative loss of anteromedial cortical support. Therefore, we should pay close attention to fracture reduction and minimize the calcar fracture gap during surgery.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Pinos Ortopédicos/efeitos adversos , Fêmur/cirurgia , Fixação Intramedular de Fraturas/efeitos adversos , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/etiologia , Fraturas do Quadril/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
9.
BMC Musculoskelet Disord ; 23(1): 224, 2022 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-35260138

RESUMO

BACKGROUD: When the reduction of long bone shaft fracture fragments is performed by a hexapod external fixator, the collision and interference between bony ends often results in an incomplete reduction and a time-consuming procedure. The purpose of this study was to present and determine the clinical effectiveness of staged correction trajectory with hexapod external fixator in the reduction of a long bone shaft fracture. METHODS: A total of 57 patients with tibial shaft fractures treated by hexapod external fixator were retrospectively analyzed from June 2016 to February 2020. Thirty-one cases (Group I) underwent a conventional one-step reduction trajectory from June 2016 to July 2018. Starting in September 2018, the other twenty-six patients (Group II) underwent staged correction trajectory (three key points reduction trajectory of "distraction-derotation-reduction"). The demographic data, residual deformities before and after correction, number of repeated X-rays after the first postoperative X-ray, duration of deformity correction process, and external fixation time were analyzed. Johner-Wruhs criteria were used to evaluate the final clinical outcomes. RESULTS: All the 57 patients achieved satisfactory fracture reduction and bone union. There were no significant differences between the two groups in demographic data, residual deformities before and after correction, external fixation time, and final clinical outcomes (p > 0.05). The average number of repeated X-rays after the first postoperative X-ray and mean duration of deformity correction process in Group II (1.3 times, 2.9 days) were all less than those in Group I (2.3 times, 5.1 days) (p < 0.05). CONCLUSION: Compared with the conventional one-step reduction trajectory, there is no differences in final clinical outcomes, but the staged correction trajectory provides less repeated X-rays and shorter reduction process duration.


Assuntos
Fixadores Externos , Fraturas da Tíbia , Diáfises , Fixação de Fratura/métodos , Humanos , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Resultado do Tratamento
10.
J Shoulder Elbow Surg ; 31(3): 571-579, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34628033

RESUMO

BACKGROUND: Scapular fracture fixation and implant selection are guided by the fracture pattern and classification, which requires accurate understanding and interpretation of the fracture lines. Three-dimensional (3D) computed tomography (CT)-based fracture pattern analysis enhances a more accurate understanding of the scapular fracture patterns. The purpose of this study was to create scapular fracture maps and identify the frequent fracture patterns using 3D reconstructed CT images. METHOD: Seventy patients treated for scapular fractures, in a single hospital, were considered for this study. Their CT images were reconstructed into 3D models and the fracture fragments were virtually reduced. The reduced 3D models were first aligned on a 3D template and 2D images were captured on the anterior, posterior, and lateral views. Then each fracture image was aligned on a corresponding 2D template and the fracture lines were transferred to the template. The 3 separate views were used to accurately capture the propagation and exit of the fractures through the scapular anatomy. These fracture lines were compiled and heat maps were generated to identify the frequent fracture zones of the scapula. RESULT: The observed scapular fractures propagated through multiple regions of the bone. Overall, the 3 most common exit zones in the scapula were the lateral (69%), medial (67%), and superior borders (60%). More specifically, the superior lateral border, medial base of the scapula spine, spinoglenoid notch, and mid-superior border were the most frequent zones of fracture in the scapular body. Simple intra-articular fractures (transverse or oblique type) were the most common (92%) fracture type in the glenoid region. CONCLUSION: Scapular fractures reveal repeatable patterns. The zones of recurrent fracture patterns can be identified from fracture and heat maps. Graphical plots of fracture and heat maps may assist surgical planning and implant design optimization.


Assuntos
Fraturas Ósseas , Fraturas Intra-Articulares , Fraturas do Ombro , Traumatismos Torácicos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Escápula/diagnóstico por imagem , Escápula/cirurgia , Tomografia Computadorizada por Raios X/métodos
11.
Medicina (Kaunas) ; 58(3)2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35334582

RESUMO

Background and Objectives: Steinmann pins are commonly used in orthopedics, with a low rate of complications. However, thermal osteonecrosis may occur when a pin is inserted using a drill. There have been no reports on late-onset fractures at the Steinmann pin insertion site. Materials and Methods: A 32-year-old man who underwent surgery for a femoral shaft fracture 5 years ago complained of proximal thigh pain 1 month after the removal of the internal device. On physical examination, the patient showed a limping gait due to pain, and tenderness was observed on the lateral aspect of the proximal thigh. Magnetic resonance imaging was performed because the symptoms did not improve, despite conservative treatment. A new fracture line was observed in the lateral cortical bone of the proximal femur. It was found that a fracture occurred at the site where the Steinmann pin was inserted for a closed reduction at the time of the first operation. The patient was instructed to limit weight bearing and to use crutches while walking. Parathyroid hormone was additionally administered to promote bone formation. Results: Six months after diagnosis, a complete union was achieved at the subtrochanteric fracture site, and the patient's pain subsided. Conclusions: A fracture that occurs as a late onset at the provisional Steinmann pin insertion site is an extremely rare complication; however, orthopedic surgeons must consider this possibility and make more efforts to lower the occurrence of thermal damage. In addition, if the patient complains of pain in the region where the pin was inserted after surgery, surgeons should spare no effort to determine whether a new fracture has occurred.


Assuntos
Fraturas do Fêmur , Fraturas de Estresse , Fraturas do Quadril , Adulto , Pinos Ortopédicos/efeitos adversos , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fixação de Fratura , Fraturas de Estresse/complicações , Fraturas do Quadril/complicações , Humanos , Masculino
12.
Eur J Orthop Surg Traumatol ; 32(7): 1407-1413, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34532756

RESUMO

Femur fractures reduction can be technically challenging due to the deforming forces exerted by the muscles causing displacement of the fracture fragments. Cerclage wiring is one of the reduction techniques frequently performed, allowing anatomical reduction of the fragments and a more stable fixation when an accurate closed reduction is not possible. We describe a modified cerclage wiring through a minimally invasive technique, using a conventional cannulated C-shaped passer.


Assuntos
Fraturas do Fêmur , Procedimentos de Cirurgia Plástica , Fios Ortopédicos , Fraturas do Fêmur/cirurgia , Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Humanos , Resultado do Tratamento
13.
Osteoporos Int ; 32(8): 1601-1608, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33537844

RESUMO

This study aimed to determine the interaction between baseline FRAX® fracture probability and romosozumab efficacy. Using an ITT approach, it was determined that the efficacy of romosozumab on clinical fracture, osteoporotic fracture, and major osteoporotic fracture is significantly greater in patients at high baseline fracture risk, when compared with placebo. INTRODUCTION: Post hoc analyses of placebo-controlled osteoporosis treatment studies have shown significantly greater reductions of fracture incidence for higher fracture risk patients. This study determined the interaction between baseline FRAX® fracture probability and romosozumab efficacy in the placebo-controlled first year of the phase 3 FRAME study (NCT01575834). METHODS: Using an ITT approach, an extension of Poisson regression analysis studied the relationship between treatment, FRAX® 10-year probability of major osteoporotic fracture (MOF, calculated without BMD) and risk of first incident fracture (adjusting for age and follow-up time). Treatment interactions considered outcomes of all clinical fractures, osteoporotic fractures, MOF, clinical vertebral fractures, and morphometric vertebral fractures. Two-sided p value of < 0.1 for the interaction between treatment and FRAX® was considered significant. RESULTS: Compared with placebo, romosozumab reduced the incidence of all fracture outcomes in the first year (range: 32% reduction in MOF [p = 0.07] to 80% reduction in clinical vertebral fractures [p = 0.038]). Significant interactions were observed between efficacy and baseline FRAX® probability for composite outcomes of clinical fractures, osteoporotic fractures, and MOF (p = 0.064-0.084), but not vertebral fractures (p > 0.3). For example, romosozumab decreased all clinical fractures by 22% at the 25th centile of FRAX® probability but the reduction was 41% at the 75th centile. Exclusion of vertebral fractures from each composite fracture outcome (i.e. only nonvertebral fractures included) showed even stronger interactions with baseline FRAX® probability (p = 0.036-0.046). CONCLUSIONS: Efficacy of romosozumab on clinical fracture, osteoporotic fracture, and MOF is significantly greater in patients at high baseline fracture risk compared with placebo.


Assuntos
Conservadores da Densidade Óssea , Osteoporose Pós-Menopausa , Fraturas por Osteoporose , Anticorpos Monoclonais , Densidade Óssea , Conservadores da Densidade Óssea/uso terapêutico , Feminino , Humanos , Osteoporose Pós-Menopausa/complicações , Osteoporose Pós-Menopausa/tratamento farmacológico , Osteoporose Pós-Menopausa/epidemiologia , Fraturas por Osteoporose/epidemiologia , Fraturas por Osteoporose/etiologia , Fraturas por Osteoporose/prevenção & controle , Medição de Risco , Fatores de Risco
14.
BMC Musculoskelet Disord ; 22(1): 187, 2021 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-33588825

RESUMO

BACKGROUND: Faster, easier, more economical and more effective versions of the minimally invasive reduction procedure for femoral shaft fractures need to be developed for use by orthopaedic surgeons. In this study, a fracture table was used to restore limb length, and long, curved haemostatic forceps and the lever principle were utilized to achieve minimally invasive reduction and intramedullary nail fixation of femoral shaft fractures. METHODS: A retrospective analysis involving 20 patients with femoral shaft fractures reduced with a fracture table; long, curved haemostatic forceps; and the lever principle was conducted. The operative effect was evaluated on the basis of the operative time, reduction time, fluoroscopy time, and intraoperative blood loss. RESULTS: All 20 cases were reduced in a closed fashion, and no conversions to open reduction were needed. The average operative time and fracture reduction time for all patients were 69.1 ± 13.5 min (range, 50-100 min) and 6.7 ± 1.9 min (range, 3-10 min), respectively. The fluoroscopy exposure time during the reduction process was 5-15 s, with an average time of 8.7 ± 2.7 s. The average intraoperative blood loss was 73.5 ± 22.5 mL (range, 50-150 mL). The patients exhibited excellent alignment in the injured limb after intramedullary nailing. Seventeen patients successfully completed a follow-up after fracture healing. The healing time ranged from 4 to 6 months. CONCLUSIONS: Displaced femoral shaft fractures in adults can be treated by a labour-saving lever technique involving fragments, 2 haemostatic forceps and soft tissue envelope-assisted closed reduction and intramedullary nail fixation. This technique is easy to perform; reduces blood loss, the fluoroscopy time and the surgical time for intraoperative reduction; and leads to excellent fracture healing.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Hemostáticos , Adulto , Pinos Ortopédicos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/efeitos adversos , Consolidação da Fratura , Humanos , Estudos Retrospectivos , Instrumentos Cirúrgicos , Resultado do Tratamento
15.
BMC Musculoskelet Disord ; 22(1): 221, 2021 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-33627096

RESUMO

BACKGROUND: The hexapod external fixator (HEF), such as the Taylor spatial frame (TSF), offering the ability of multidirectional deformities correction without changing the structure, whereas there are so many parameters for surgeons to measure and subjective errors will occur inevitably. The purpose of this study was to evaluate the effectiveness of a new method based on computer-assisted three-dimensional (3D) reconstruction and hexapod external fixator for long bone fracture reduction and deformity correction without calculating the parameters needed by the traditional usage. METHODS: This retrospective study consists of 25 patients with high-energy tibial diaphyseal fractures treated by the HEF at our institution from January 2016 to June 2018, including 22 males and 3 females with a mean age of 42 years (range 14-63 years). Hexapod external fixator treatments were conducted to manage the multiplanar posttraumatic deformities with/without poor soft-tissue that were not suitable for internal fixation. Computer-assisted 3D reconstruction and trajectory planning of the reduction by Mimics were applied to perform virtual fracture reduction and deformity correction. The electronic prescription derived from the length changes of the six struts were calculated by SolidWorks. Fracture reduction was conducted by adjusting the lengths of the six struts according to the electronic prescription. Effectiveness was evaluated by the standard anteroposterior (AP) and lateral X-rays after reduction. RESULTS: All patients acquired excellent functional reduction and achieved bone union in our study. After correction, the mean translation (1.0 ± 1.1 mm) and angulation (0.8 ± 1.2°) on the coronal plane, mean translation (0.8 ± 1.0 mm) and angulation (0.3 ± 0.8°) on the sagittal plane were all less than those (6.1 ± 4.9 mm, 5.2 ± 3.2°, 4.2 ± 3.5 mm, 4.0 ± 2.5°) before correction (P < 0.05). CONCLUSIONS: The computer-assisted three-dimensional reconstruction and hexapod external fixator-based method allows surgeons to conduct long bone fracture reduction and deformity correction without calculating the parameters needed by the traditional usage. This method is suggested to apply in those unusually complex cases with extensive soft tissue damage and where internal fixation is impossible or inadvisable.


Assuntos
Fixadores Externos , Fraturas da Tíbia , Adolescente , Adulto , Feminino , Fixação de Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tíbia , Adulto Jovem
16.
BMC Musculoskelet Disord ; 22(1): 924, 2021 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-34727909

RESUMO

OBJECTIVES: To compare intraoperative 3D fluoroscopy with a ceiling-mounted flat panel detector in plate osteosynthesis of distal radius fractures (AO/OTA 2R3C1.2) with volar locking plate systems to conventional 2D fluoroscopy for detection of insufficient fracture reduction, plate misplacement and protruding screws. METHODS: Using a common volar approach on 12 cadaver forearms, total intraarticular distal radius fractures were induced, manually reduced and internally fixated with a 2.4 distal radius locking compression plate. 2D (anterior-posterior and lateral) and 3D (rotational) fluoroscopic images were taken as well as computed tomographies. Fluoroscopic images, Cone Beam CT (CBCT), 360° rotating sequences (so called "Movies") and CT scans were co-evaluated by a specialist orthopedic surgeon and a specialist radiologist regarding quality of fracture reduction, position of plate, position of the three distal locking screws and position of the three diaphyseal screws. In reference to gold standard CT, sensitivity and specifity were analyzed. RESULTS: "Movie" showed highest sensitivity for detection of insufficient fracture reduction (88%). Sensitivity for detection of incorrect position of plate was 100% for CBCT and 90% for "Movie." For intraarticular position of screws, 2D fluoroscopy and CBCT showed highest sensitivity and specifity (100 and 91%, respectively). Regarding detection of only marginal intraarticular position of screws, sensitivity and specifity of 2D fluoroscopy reached 100% (CBCT: 100 and 83%). "Movie" showed highest sensitivity for detection of overlapping position of screws (100%). When it comes to specifity, CBCT achieved 100%. Regarding detection of only marginal overlapping position of screws, 2D fluoroscopy and "Movie" showed highest sensitivity (100%). CBCT achieved highest specifity (100%). CONCLUSION: As for assessment of quality of fracture reduction and detection of incorrect position of plate as well as overlapping position of the three diaphyseal screws CBCT and "Movie" are comparable to CT - especially when combined. Particularly sensitivity is high compared to standard 2D fluoroscopy.


Assuntos
Fraturas do Rádio , Placas Ósseas , Parafusos Ósseos , Fluoroscopia , Fixação Interna de Fraturas , Humanos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia
17.
Int Orthop ; 45(7): 1837-1844, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34021374

RESUMO

INTRODUCTION: The use of per-operative cone beam tomography imaging for displaced acetabular fractures yields increased post-operative articular reduction accuracy. This study evaluates the need for total hip replacement (THR) and hip-related functional outcomes in patients with displaced acetabular fractures treated with O-ARM guidance compared to those treated under C-ARM guidance. MATERIALS AND METHODS: This is a prospective matched cohort study. Adult patients (35) with acetabular fractures operated under O-ARM guidance were included. These were matched (age, fracture type) to classically treated patients (35) from our data base. The primary outcome was the need for THR during three year follow-up period. Secondary outcomes were functional scores [Harris Hip score (HHS), Postel-Merle d'Aubigné (PMA)] and hip osteoarthritis grade at three year follow-up. Correlation between reduction gap and THR was evaluated. RESULTS: At three years, five patients were lost to follow-up in O-ARM group and four in control group. Two patients (6.66%) in the O-ARM group needed THR compared to eight patients in controls (25.80%) (p = 0.046). Hip X-ray osteoarthritis grade averaged 0.00 in patients without THR in O-ARM group compared to 0.22 in patients without THR in controls (p = 0.008). HHS averaged 95.79 in patients without THR in O-ARM group, compared to 93.82 in patients without THR in the control group (p = 0.41%). PMA averaged 17.25 in patients without THR in the O-ARM group compared to 17.04 in patients without THR in group 2 (p = 0.37). Evaluation of correlation between reduction gap and THR rate yielded OR = 1.22 (1.06-1.45). DISCUSSION: Increased accuracy in articular reduction, with per-operative three-dimensional control of impaction, in acetabular fractures led to significantly less need for THR in patients treated under O-ARM. Patients in both groups are comparable for functional outcomes because those with the lowest scores were offered THR. Per-operative cone beam guidance and navigation use are recommended in tertiary referral centres for acetabular trauma.


Assuntos
Artroplastia de Quadril , Fraturas Ósseas , Cirurgia Assistida por Computador , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Adulto , Estudos de Coortes , Seguimentos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Imageamento Tridimensional , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Arch Orthop Trauma Surg ; 141(4): 593-602, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32519074

RESUMO

BACKGROUND: Navigational techniques in orthopaedic trauma surgery have developed over the last years leaving the question of really improving quality of treatment. Especially in marginal surgical indications, their benefit has to be evident. The aim of this study was to compare reduction and screw position following 3D-navigated and conventional percutaneous screw fixation of acetabular fractures. The study hypothesis postulated that better fracture reduction and better screw position are obtained with 3D navigation. MATERIALS AND METHODS: Preoperative and postoperative CT scans of 37 acetabular fractures treated by percutaneous screw fixation (24 3D-navigated, 13 conventional) were evaluated. Differences in pre- and postoperative fracture gaps and steps were compared in all reconstructions as well as the screw position relative to the joint and the fracture. RESULTS: The differences in fracture gaps and fracture steps with and without 3D navigation were not significantly different. Distance of the screw from the joint line, angle difference between screw and ideal angle relative to the fracture line, length of the possible corridor used and position of the screw thread did not show any significant differences. CONCLUSION: Comparison of 3D-navigated and conventional percutaneous surgery of acetabular fractures on the basis of pre- and postoperative CTs revealed no significant differences in terms of fracture reduction and screw position.


Assuntos
Acetábulo , Parafusos Ósseos , Fixação de Fratura/métodos , Fraturas Ósseas , Cirurgia Assistida por Computador/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/lesões , Acetábulo/cirurgia , Fluoroscopia , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Imageamento Tridimensional
19.
J Foot Ankle Surg ; 60(4): 712-717, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33789807

RESUMO

The incidence of geriatric ankle fractures is rising and the potential for complications is high in this population. Little is known about factors associated with increased postoperative complications after surgical fixation of ankle fractures in older-age patients. The purpose of this retrospective cohort study was to assess the epidemiology and risk factors for complications after surgically treated ankle fractures in geriatric patients. All patients who were 65 years or older and had a surgically treated ankle fracture were included. Pilon fractures, patients who were initially treated conservatively or who had less than 1 month of follow-up were excluded. Postoperative complications, demographic-, fracture- and surgical data of 282 patients were recorded from two level 2 trauma centers between 2012 and 2017. A total of 87 (30.9%) patients developed a complication, of which wound related complications were most frequently reported. Superficial and deep wound infections were observed in 27 (9.6%) and 18 (6.4%) patients, respectively. Multivariate regression analysis demonstrated increased age to be an independent predictive variable for the occurrence of postoperative complications (odds ratio 1.04; 95% confidence interval 1.00-1.09), while cast immobilization for more than 2 weeks was a protective factor for the development of wound related complications (odds ratio 0.34; 95% confidence interval 0.17-0.66). In conclusion, the incidence of postoperative complications among geriatric patients after surgical treatment of ankle fractures is high and patients should be informed accordingly.


Assuntos
Fraturas do Tornozelo , Fraturas da Tíbia , Idoso , Fixação Interna de Fraturas , Humanos , Complicações Pós-Operatórias , Estudos Retrospectivos , Infecção da Ferida Cirúrgica , Resultado do Tratamento
20.
Int Orthop ; 44(6): 1201-1208, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32248267

RESUMO

PURPOSE: To investigate the capability of intra-operative fluoroscopy to determine the reduction quality of intertrochanteric fractures and to determine which view (anteroposterior [AP] or lateral) can better predict the reduction quality. METHODS: A retrospective analysis of 128 patients with intertrochanteric fractures. Two observers were asked to independently evaluate the quality of reduction (positive or non-positive support) based on intra-operative fluoroscopy (AP and lateral view). Results based on CT scans were considered as the gold standard. Sensitivity, specificity, percentage of correct interpretations, and agreement were calculated. RESULTS: At the first reading, sensitivity, false-negative rate, specificity, false-positive rate, and percentage of correct interpretations were 86.1%, 13.9%, 69.4%, 30.6%, and 79.7% for junior resident and 81.0%, 19.0%, 67.3%, 32.7%, and 75.8% for senior resident (all p > 0.05). It was highly predictive of a reliable cortical support when cortical position in AP view was consistent with that in lateral view (85/85, 100% for junior, and 86/86, 100% for senior). Lateral view was generally predictive of a final cortical support when the position between AP and lateral view was inconsistent (90.7% [39/43] vs 9.3% [4/43] for junior, p < 0.001; 92.9% [39/42] vs 7.1% [3/42] for senior). Comparable results were reported at the second reading. The average inter-observer and intra-observer agreement was 0.670 and 0.654, respectively. CONCLUSIONS: We should ensure the cortical support for both AP and lateral view are positive intra-operatively as far as possible. Even if this is not possible, we need to make sure the lateral position is positive support.