Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Mol Imaging Biol ; 22(3): 703-710, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31309370

RESUMO

PURPOSE: To provide reliable and reproducible heart/mediastinum (H/M) ratio cut-off values for parkinsonian disorders using two machine learning techniques, Support Vector Machines (SVM) and Random Forest (RF) classifier, applied to [123I]MIBG cardiac scintigraphy. PROCEDURES: We studied 85 subjects, 50 with idiopathic Parkinson's disease, 26 with atypical Parkinsonian syndromes (P), and 9 with essential tremor (ET). All patients underwent planar early and delayed cardiac scintigraphy after [123I]MIBG (111 MBq) intravenous injection. Images were evaluated both qualitatively and quantitatively; the latter by the early and delayed H/M ratio obtained from regions of interest (ROIt1 and ROIt2) drawn on planar images. SVM and RF classifiers were finally used to obtain the correct cut-off value. RESULTS: SVM and RF produced excellent classification performances: SVM classifier achieved perfect classification and RF also attained very good accuracy. The better cut-off for H/M value was 1.55 since it remains the same for both ROIt1 and ROIt2. This value allowed to correctly classify PD from P and ET: patients with H/M ratio less than 1.55 were classified as PD while those with values higher than 1.55 were considered as affected by parkinsonism and/or ET. No difference was found when early or late H/M ratio were considered separately thus suggesting that a single early evaluation could be sufficient to obtain the final diagnosis. CONCLUSIONS: Our results evidenced that the use of SVM and CT permitted to define the better cut-off value for H/M ratios both in early and in delayed phase thus underlining the role of [123I]MIBG cardiac scintigraphy and the effectiveness of H/M ratio in differentiating PD from other parkinsonism or ET. Moreover, early scans alone could be used for a reliable diagnosis since no difference was found between early and late. Definitely, a larger series of cases is needed to confirm this data.


Assuntos
3-Iodobenzilguanidina , Coração/diagnóstico por imagem , Radioisótopos do Iodo , Mediastino/diagnóstico por imagem , Transtornos Parkinsonianos/classificação , Transtornos Parkinsonianos/diagnóstico por imagem , Cintilografia/métodos , 3-Iodobenzilguanidina/química , 3-Iodobenzilguanidina/farmacocinética , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Radioisótopos do Iodo/química , Radioisótopos do Iodo/farmacocinética , Masculino , Pessoa de Meia-Idade , Transtornos Parkinsonianos/patologia , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/metabolismo , Estudos Retrospectivos , Máquina de Vetores de Suporte
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa