1.
J Surg Res ; 299: 290-297, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38788465

RESUMO

INTRODUCTION: More than 1.2 million pulmonary artery catheters (PACs) are used in cardiac patients per annum within the United States. However, it is contraindicated in traditional 1.5 and 3T magnetic resonance imaging (MRI) scans. We aimed to test preclinical and clinical safety of using this imaging modality given the potential utility of needing it in the clinical setting. METHODS: We conducted two phantom experiments to ensure that the electromagnetic field power deposition associated with bare and jacketed PACs was safe and within the acceptable limit established by the Food and Drug Administration. The primary end points were the safety and feasibility of performing Point-of-Care (POC) MRI without imaging-related adverse events. We performed a preclinical computational electromagnetic simulation and evaluated these findings in nine patients with PACs on veno-arterial extracorporeal membrane oxygenation. RESULTS: The phantom experiments showed that the baseline point specific absorption rate through the head averaged 0.4 W/kg. In both the bare and jacketed catheters, the highest net specific absorption rates were at the neck entry point and tip but were negligible and unlikely to cause any heat-related tissue or catheter damage. In nine patients (median age 66, interquartile range 42-72 y) with veno-arterial extracorporeal membrane oxygenation due to cardiogenic shock and PACs placed for close hemodynamic monitoring, POC MRI was safe and feasible with good diagnostic imaging quality. CONCLUSIONS: Adult ECMO patients with PACs can safely undergo point-of-care low-field (64 mT) brain MRI within a reasonable timeframe in an intensive care unit setting to assess for acute brain injury that might otherwise be missed with conventional head computed tomography.


Assuntos
Encéfalo , Cateterismo de Swan-Ganz , Oxigenação por Membrana Extracorpórea , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Masculino , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Feminino , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Idoso , Adulto , Encéfalo/diagnóstico por imagem , Cateterismo de Swan-Ganz/instrumentação , Cateterismo de Swan-Ganz/efeitos adversos , Estudos de Viabilidade
2.
Crit Care ; 28(1): 23, 2024 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-38229147

RESUMO

BACKGROUND: The use of the passive leg raising (PLR) is limited in acute brain injury (ABI) patients with increased intracranial pressure (ICP) since the postural change of the head may impact on ICP and cerebral autoregulation. However, the PLR use may prevent a positive daily fluid balance, which had been recently associated to worse neurological outcomes. We therefore studied early and delayed effects of PLR on the cerebral autoregulation of patients recovering from ABI. MATERIALS AND METHODS: This is a Prospective, observational, single-center study conducted in critically ill patients admitted with stable ABI and receiving invasive ICP monitoring, multimodal neuromonitoring and continuous hemodynamic monitoring. The fluid challenge consisted of 500 mL of crystalloid over 10 min; fluid responsiveness was defined as cardiac index increase ≥ 10%. Comparisons between different variables at baseline and after PLR were made by paired Wilcoxon signed-rank test. The correlation coefficients between hemodynamic and neuromonitoring variables were assessed using Spearman's rank test. RESULTS: We studied 23 patients [12 patients (52.2%) were fluid responders]. The PLR significantly increased ICP [from 13.7 (8.3-16.4) to 15.4 (12.0-19.2) mmHg; p < 0.001], cerebral perfusion pressure (CPP) [from 51.1 (47.4-55.6) to 56.4 (49.6-61.5) mmHg; p < 0.001] and the pressure reactivity index (PRx) [from 0.12 (0.01-0.24) to 0.43 (0.34-0.46) mmHg; p < 0.001]. Regarding Near Infrared Spectroscopy (NIRS)-derived parameters, PLR significantly increased the arterial component of regional cerebral oxygen saturation (O2Hbi) [from 1.8 (0.8-3.7) to 4.3 (2.5-5.6) µM cm; p < 0.001], the deoxygenated hemoglobin (HHbi) [from 1.6 (0.2-2.9) to 2.7 (1.4-4.0) µM cm; p = 0.007] and total hemoglobin (cHbi) [from 3.6 (1.9-5.3) to 7.8 (5.2-10.3): p < 0.001]. In all the patients who had altered autoregulation after PLR, these changes persisted ten minutes afterwards. After the PLR, we observed a significant correlation between MAP and CPP and PRx. CONCLUSIONS: In ABI patient with stable ICP, PLR test increased ICP, but mostly within safety values and thresholds. Despite this, cerebral autoregulation was importantly impaired, and this persisted up to 10 min after the end of the maneuvre. Our results discourage the use of PLR test in ABI even when ICP is stable.


Assuntos
Lesões Encefálicas , Pressão Intracraniana , Humanos , Pressão Intracraniana/fisiologia , Perna (Membro) , Encéfalo , Homeostase/fisiologia , Hemoglobinas , Circulação Cerebrovascular/fisiologia
3.
J Intensive Care Med ; 39(7): 665-671, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38215002

RESUMO

Background: Blood pressure (BP) is routinely invasively monitored by an arterial catheter in the intensive care unit (ICU). However, the available data comparing the accuracy of noninvasive methods to arterial catheters for measuring BP in the ICU are limited by small numbers and diverse methodologies. Purpose: To determine agreement between invasive arterial blood pressure monitoring (IABP) and noninvasive blood pressure (NIBP) in critically ill patients. Methods: This was a single center, observational study of critical ill adults in a tertiary care facility evaluating agreement (≤10% difference) between simultaneously measured IABP and NIBP. We measured clinical features at time of BP measurement inclusive of patient demographics, laboratory data, severity of illness, specific interventions (mechanical ventilation and dialysis), and vasopressor dose to identify particular clinical scenarios in which measurement agreement is more or less likely. Results: Of the 1852 critically ill adults with simultaneous IABP and NIBP readings, there was a median difference of 6 mm Hg in mean arterial pressure (MAP), interquartile range (1-12), P < .01. A logistic regression analysis identified 5 independent predictors of measurement discrepancy: increasing doses of norepinephrine (adjusted odds ratio [aOR] 1.10 [95% confidence interval, CI 1.08-1.12] P = .03 for every change in 5 µg/min), lower MAP value (aOR 0.98 [0.98-0.99] P < .01 for every change in 1 mm Hg), higher body mass index (aOR 1.04 [1.01-1.09] P = .01 for an increase in 1), increased patient age (aOR 1.31 [1.30-1.37] P < .01 for every 10 years), and radial arterial line location (aOR 1.74 [1.16-2.47] P = .04). Conclusions: There was broad agreement between IABP and NIBP in critically ill patients over a range of BPs and severity of illness. Several variables are associated with measurement discrepancy; however, their predictive capacity is modest. This may guide future study into which patients may specifically benefit from an arterial catheter.


Assuntos
Determinação da Pressão Arterial , Estado Terminal , Unidades de Terapia Intensiva , Humanos , Estado Terminal/terapia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Determinação da Pressão Arterial/métodos , Adulto , Cuidados Críticos/métodos , Vasoconstritores/uso terapêutico , Vasoconstritores/administração & dosagem , Modelos Logísticos , Pressão Sanguínea/fisiologia , Pressão Arterial/fisiologia
4.
J Intensive Care Med ; : 8850666231222220, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38173252

RESUMO

The high respiratory and cardiac drive is essential to the host-organ unregulated response. When a primary disease and an unregulated secondary response are uncontrolled, the patient may present in a high respiratory and cardiac drive state. High respiratory drive can cause damage to the lungs, pulmonary circulation, and diaphragm, while high cardiac drive can lead to fluid leakage and infiltration as well as pulmonary interstitial edema. A "respiratory and cardiac dual high drive" state may be a sign of an unregulated response and can lead to secondary lung injury through the increase of transvascular pressure and pulmonary microcirculation injury. Ultrasound examination of the lung, heart, and diaphragm is important when evaluating the phenotype of high respiratory drive in critically ill patients. Ultrasound assessment can guide sedation, analgesia, and antistress treatment and reduce the risk of high respiratory and cardiac drive-induced lung injury in these patients.

5.
J Intensive Care Med ; 39(7): 628-635, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38190576

RESUMO

Background: The likelihood of a patient being preload responsive-a state where the cardiac output or stroke volume (SV) increases significantly in response to preload-depends on both cardiac filling and function. This relationship is described by the canonical Frank-Starling curve. Research Question: We hypothesize that a novel method for phenotyping hypoperfused patients (ie, the "Doppler Starling curve") using synchronously measured jugular venous Doppler as a marker of central venous pressure (CVP) and corrected flow time of the carotid artery (ccFT) as a surrogate for SV will refine the pretest probability of preload responsiveness/unresponsiveness. Study Design and Methods: We retrospectively analyzed a prospectively collected convenience sample of hypoperfused adult emergency department (ED) patients. Doppler measurements were obtained before and during a preload challenge using a wireless, wearable Doppler ultrasound system. Based on internal jugular and carotid artery Doppler surrogates of CVP and SV, respectively, we placed hemodynamic assessments into quadrants (Qx) prior to preload augmentation: low CVP with normal SV (Q1), high CVP and normal SV (Q2), low CVP and low SV (Q3) and high CVP and low SV (Q4). The proportion of preload responsive and unresponsive assessments in each quadrant was calculated based on the maximal change in ccFT (ccFTΔ) during either a passive leg raise or rapid fluid challenge. Results: We analyzed 41 patients (68 hemodynamic assessments) between February and April 2021. The prevalence of each phenotype was: 15 (22%) in Q1, 8 (12%) in Q2, 39 (57%) in Q3, and 6 (9%) in Q4. Preload unresponsiveness rates were: Q1, 20%; Q2, 50%; Q3, 33%, and Q4, 67%. Interpretation: Even fluid naïve ED patients with sonographic estimates of low CVP have high rates of fluid unresponsiveness, making dynamic testing valuable to prevent ineffective IVF administration.


Assuntos
Artérias Carótidas , Hidratação , Veias Jugulares , Ultrassonografia Doppler , Humanos , Projetos Piloto , Masculino , Feminino , Hidratação/métodos , Pessoa de Meia-Idade , Veias Jugulares/diagnóstico por imagem , Estudos Prospectivos , Artérias Carótidas/diagnóstico por imagem , Idoso , Ressuscitação/métodos , Pressão Venosa Central/fisiologia , Estudos Retrospectivos , Adulto , Volume Sistólico/fisiologia , Débito Cardíaco/fisiologia , Serviço Hospitalar de Emergência , Hemodinâmica
6.
J Intensive Care Med ; : 8850666241257417, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38794858

RESUMO

BACKGROUND: Arterial catheter placement for hemodynamic monitoring is commonly performed in critically ill patients. The radial and femoral arteries are the two sites most frequently used; there is limited data on the use of the axillary artery for this purpose. The aim of this study was to investigate the rate of complications from ultrasound-guided axillary artery catheter placement in critically ill patients. METHODS: A retrospective study at a tertiary care center of patients admitted to an intensive care unit who had ultrasound-guided axillary artery catheter placement during admission. Primary outcome of interest was catheter related complications, including bleeding, vascular complications, compartment syndrome, stroke or air embolism, catheter malfunction, and need for surgical intervention. RESULTS: This study identified 88 patients who had an ultrasound-guided axillary artery catheter placed during their admission. Of these 88, nine patients required multiple catheters placed, for a total of 99 axillary artery catheter placement events. The median age was 64 [IQR 48, 71], 41 (47%) were female, and median body mass index (BMI) was 26 [IQR 22, 30]. The most common complication was minor bleeding (11%), followed by catheter malfunction (2%), and vascular complications (2%). Univariate analyses did not show any association between demographics and clinical variables, and complications related to axillary arterial catheter. CONCLUSION: The most common complication found with ultrasound-guided axillary artery catheter placement was minor bleeding, followed by catheter malfunction, and vascular complications. Ultrasound-guided axillary arterial catheters are an alternative in patients in whom radial or femoral arterial access is difficult or not possible to achieve.

7.
J Intensive Care Med ; 39(7): 655-664, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38173245

RESUMO

Adequate fluid therapy is crucial for resuscitation after major burns. To adapt this to individual patient demands, standard is adjustment of volume to laboratory parameters and values of enhanced hemodynamic monitoring. To implement calibrated parameters, patients must have reached the intensive care unit (ICU). The aim of this study was, to evaluate the use of an auto-calibrated enhanced hemodynamic monitoring device to improve fluid management before admission to ICU. We used PulsioflexProAqt® (Getinge) during initial treatment and burn shock resuscitation. Analysis was performed regarding time of measurement, volume management, organ dysfunction, and mortality. We conducted a monocentre, prospective cohort study of 20 severely burned patients, >20% total body surface area (TBSA), receiving monitoring immediately after admission. We compared to 57 patients, matched in terms of TBSA, age, sex, and existence of inhalation injury out of a retrospective control group, who received standard care. Hemodynamic measurement with autocalibrated monitoring started significantly earlier: 3.75(2.67-6.0) hours (h) after trauma in the study group versus 13.6(8.1-17.5) h in the control group (P < .001). Study group received less fluid after 6 h: 1.7(1.2-2.2) versus 2.3(1.6-2.8) ml/TBSA%/kg, P = .043 and 12 h: 3.0(2.5-4.0) versus 4.2(3.1-5.0) ml/TBSA%/kg, P = .047. Dosage of norepinephrine was higher after 18 h in the study group: 0.20(0.12-0.3) versus 0.08(0.02-0.18) µg/kg/min, P = .014. The study group showed no adult respiratory distress syndrome versus 21% in the control group, P = .031. There was no difference in other organ failures, organ replacement therapy, and mortality. The use of auto-calibrated enhanced hemodynamic monitoring is a fast and feasible way to guide early fluid therapy after burn trauma. It reduces the time to reach information about patient's volume capacity. Management of fluid application changed to a more restrictive fluid use in the early period of burn shock and led to a reduction of pulmonary complications.


Assuntos
Queimaduras , Hidratação , Ressuscitação , Choque , Humanos , Queimaduras/terapia , Queimaduras/fisiopatologia , Masculino , Feminino , Hidratação/métodos , Estudos Prospectivos , Pessoa de Meia-Idade , Adulto , Choque/terapia , Choque/fisiopatologia , Ressuscitação/métodos , Monitorização Hemodinâmica/métodos , Hemodinâmica/fisiologia , Unidades de Terapia Intensiva , Idoso , Monitorização Fisiológica/métodos
8.
BMC Anesthesiol ; 24(1): 201, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844869

RESUMO

BACKGROUND: Significant hemodynamic changes occur during liver transplantation, emphasizing the importance of precious and continuous monitoring of cardiac output, cardiac index, and other parameters. Although the monitoring of cardiac output by pulse indicator continuous cardiac output (PiCCO) was statistically homogeneous compared to the clinical gold standard pulmonary artery catheterization (PAC) in previous studies of liver transplantation, there are fewer statistical methods for the assessment of its conclusions, and a lack of comparisons of other hemodynamic parameters (e.g., SVRI, systemic vascular resistance index). Some studies have also concluded that the agreement between PiCCO and PAC is not good enough. Overall, there are no uniform conclusions regarding the agreement between PiCCO and PAC in previous studies. This study evaluates the agreement and trending ability of relevant hemodynamic parameters obtained with PiCCO compared to the clinical gold standard PAC from multiple perspectives, employing various statistical methods. METHODS: Fifty-two liver transplantation patients were included. Cardiac output (CO), cardiac index (CI), SVRI and stroke volume index (SVI) values were monitored at eight time points using both PiCCO and PAC. The results were analyzed by Bland-Altman analysis, Passing-bablok regression, intra-class correlation coefficient (ICC), 4-quadrant plot, polar plot, and trend interchangeability method (TIM). RESULTS: The Bland-Altman analysis revealed high percentage errors for PiCCO: 54.06% for CO, 52.70% for CI, 62.18% for SVRI, and 51.97% for SVI, indicating poor accuracy. While Passing-Bablok plots showed favorable agreement for SVRI overall and during various phases, the agreement for other parameters was less satisfactory. The ICC results confirmed good overall agreement between the two devices across most parameters, except for SVRI during the new liver phase, which showed poor agreement. Additionally, four-quadrant and polar plot analyses indicated that all agreement rate values fell below the clinically acceptable threshold of over 90%, and all angular deviation values exceeded ± 5°, demonstrating that PiCCO is unable to meet the acceptable trends. Using the TIM, the interchangeability rates were found to be quite low: 20% for CO and CI, 16% for SVRI, and 13% for SVI. CONCLUSIONS: Our study revealed notable disparities in absolute values of CO, CI, SVRI and SVI between PiCCO and PAC in intraoperative liver transplant settings, notably during the neohepatic phase where errors were particularly pronounced. Consequently, these findings highlight the need for careful consideration of PiCCO's advantages and disadvantages in liver transplantation scenarios, including its multiple parameters (such as the encompassing extravascular lung water index), against its limited correlation with PAC.


Assuntos
Débito Cardíaco , Cateterismo de Swan-Ganz , Hemodinâmica , Transplante de Fígado , Monitorização Intraoperatória , Transplante de Fígado/métodos , Humanos , Cateterismo de Swan-Ganz/métodos , Débito Cardíaco/fisiologia , Masculino , Pessoa de Meia-Idade , Feminino , Hemodinâmica/fisiologia , Monitorização Intraoperatória/métodos , Idoso , Adulto , Artéria Pulmonar/fisiologia
9.
BMC Anesthesiol ; 24(1): 187, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38796436

RESUMO

PURPOSE: Oxygen delivery (DO2) and its monitoring are highlighted to aid postoperative goal directed therapy (GDT) to improve perioperative outcomes such as acute kidney injury (AKI) after high-risk cardiac surgeries associated with multiple morbidities and mortality. However, DO2 monitoring is neither routine nor done postoperatively, and current methods are invasive and only produce intermittent DO2 trends. Hence, we proposed a novel algorithm that simultaneously integrates cardiac output (CO), hemoglobin (Hb) and oxygen saturation (SpO2) from the Edwards Life Sciences ClearSight System® and Masimo SET Pulse CO-Oximetry® to produce a continuous, real-time DO2 trend. METHODS: Our algorithm was built systematically with 4 components - machine interface to draw data with PuTTY, data extraction with parsing, data synchronization, and real-time DO2 presentation using a graphic-user interface. Hb readings were validated. RESULTS: Our algorithm was implemented successfully in 93% (n = 57 out of 61) of our recruited cardiac surgical patients. DO2 trends and AKI were studied. CONCLUSION: We demonstrated a novel proof-of-concept and feasibility of continuous, real-time, non-invasive DO2 monitoring, with each patient serving as their own control. Our study also lays the foundation for future investigations aimed at identifying personalized critical DO2 thresholds and optimizing DO2 as an integral part of GDT to enhance outcomes in perioperative cardiac surgery.


Assuntos
Algoritmos , Procedimentos Cirúrgicos Cardíacos , Estudos de Viabilidade , Oximetria , Oxigênio , Humanos , Procedimentos Cirúrgicos Cardíacos/métodos , Masculino , Feminino , Oxigênio/metabolismo , Oxigênio/administração & dosagem , Oxigênio/sangue , Oximetria/métodos , Idoso , Pessoa de Meia-Idade , Estudo de Prova de Conceito , Injúria Renal Aguda , Monitorização Fisiológica/métodos , Débito Cardíaco/fisiologia , Hemoglobinas/metabolismo , Hemoglobinas/análise , Saturação de Oxigênio/fisiologia
10.
J Cardiothorac Vasc Anesth ; 38(2): 417-422, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38114369

RESUMO

OBJECTIVES: The IKORUS system (Vygon, Écouen, France) allows continuous monitoring of the urethral perfusion index (uPI) using a photoplethysmographic sensor mounted near the base of the balloon of a dedicated urinary catheter. We aimed to test the hypothesis that the uPI decreases during off-pump coronary artery bypass (OPCAB) surgery and to investigate the relationship between the uPI and macrocirculatory variables. DESIGN: Prospective observational study. SETTING: University Medical Center Hamburg-Eppendorf, Hamburg, Germany. PARTICIPANTS: Twenty patients having OPCAB surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The primary endpoint was changes in the uPI during OPCAB surgery. We additionally investigated associations between the uPI and cardiac output, mean arterial pressure, heart rate, and point-of-care variables. Twenty patients with 24,137 uPI measurements were included. Overall, there was a high interindividual variability in the uPI. Compared with the preparation phase (during which the median [interquartile range] uPI was 7.7 [5.6-12.0]), the uPI decreased by 14% (95% CI 13%-15%) during the bypass grafting phase, by 35% (95% CI 34%-36%) during the cardiac positioning phase, and by 7% (95% CI 6%-9%) during hemostasis. There was no clinically important association between uPI and either cardiac output, mean arterial pressure, or heart rate. CONCLUSIONS: The uPI decreases during OPCAB surgery, specifically during the cardiac positioning phase. There was no clinically important association between uPI and either cardiac output, mean arterial pressure, or heart rate. It, therefore, remains to be determined whether intraoperative uPI decreases are clinically important, reflect alterations in intra-abdominal tissue perfusion that are not reflected by systemic macrohemodynamics, and can help clinicians guide therapeutic interventions.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Humanos , Pressão Arterial , Débito Cardíaco/fisiologia , Frequência Cardíaca/fisiologia , Índice de Perfusão , Estudos Prospectivos
11.
J Cardiothorac Vasc Anesth ; 38(5): 1127-1134, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38369449

RESUMO

OBJECTIVES: There is accumulating evidence that blood pressure management might be associated with end-organ dysfunction after cardiac surgery. This study aimed to investigate the impact of intraoperative hypotension (IOH) on adverse neurologic outcomes and mortality. DESIGN: A single-center retrospective cohort study. SETTING: The Heart and Diabetes Centre Bad Oeynhausen NRW, Ruhr-University Bochum. PARTICIPANTS: This retrospective cohort study included 31,315 adult patients who underwent elective cardiac surgery at the authors' institution between January 2009 and December 2018. INTERVENTIONS: All cardiac surgery procedures except assist device implantation, organ transplantation, and emergency surgery. MEASUREMENTS AND MAIN RESULTS: Adverse neurologic outcomes were defined as postoperative delirium and stroke. IOH was defined as mean arterial pressure below 60 mmHg for >2 minutes. The frequency of IOH episodes and the cumulative IOH duration were recorded. The association between IOH and adverse neurologic outcomes was examined with unadjusted statistical analysis and multiple logistic regression analysis. Eight hundred forty-nine (2.9%) patients developed postoperative stroke, and 2,401 (7.7%) patients developed postoperative delirium. The frequency of IOH episodes was independently associated with postoperative delirium in the multiple logistic regression analysis (odds ratio 1.02, 95% CI 1.003-1.03, p < 0.001), whereas there was no association between it and stroke. CONCLUSION: This large retrospective monocentric cohort study revealed that increased episodes of IOH were associated with the risk of developing postoperative delirium after cardiac surgery. This might have important clinical implications with respect to careful and precise hemodynamic monitoring and proactive treatment, especially in patients with increased risk for postoperative delirium.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Delírio do Despertar , Hipotensão , Acidente Vascular Cerebral , Adulto , Humanos , Pressão Sanguínea , Estudos Retrospectivos , Estudos de Coortes , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Intraoperatórias , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Hipotensão/diagnóstico , Hipotensão/epidemiologia , Hipotensão/etiologia , Acidente Vascular Cerebral/complicações
12.
Artigo em Inglês | MEDLINE | ID: mdl-38897888

RESUMO

OBJECTIVE: Wide variations exist in the use of pulmonary artery catheters (PACs) and echocardiography in the field of cardiac surgery. DESIGN: A national survey promoted by the Italian Association of Cardio-Thoracic Anesthesiologists and Intensive Care was conducted. SETTING: The study occurred in Italian cardiac surgery centers (n = 71). PARTICIPANTS: Anesthesiologists-intensivists were enrolled. INTERVENTIONS: Anonymous questionnaires were used to investigate the use of PACs and echocardiography in the operating room (OR) and intensive care unit (ICU). MEASUREMENTS AND MAIN RESULTS: A total of 257 respondents (32.2% response rate) from 59 centers (83.1% response rate) participated. Use of PACs seems less common in ORs (median insertion in 20% [5-70] of patients), with slightly higher use in ICUs; in about half of cases, it was the continuous cardiac output monitoring system of choice. Almost two-thirds of respondents recently inserted at least one PAC within a few hours of ICU admission, despite its need being largely preoperatively predictable. Protocols regulating PAC insertion were reported by 25.3% and 28% of respondents (OR and ICU, respectively). Transesophageal echocardiography (TEE) was performed intraoperatively in >75% of patients by 86.4% of respondents; only 23.7% stated that intraoperative TEE relied on anesthesiologists. Tissue Doppler and/or 3D imaging were widely available (87.4% and 82%, respectively), but only 37.8% and 24.3% of respondents self-declared skills in these modalities, respectively; 77.1% of respondents had no echocardiography certification, nor were pursuing certification (various reasons); 40.9% had not attended recent echocardiography courses. Lower PAC use was associated with university hospitals (OR: p = 0.014, ICU: p = 0.032) and with lower interventions/year (OR: p = 0.023). Higher independence in performing TEE was reported in university hospitals (OR: p < 0.001; ICU: p = 0.006), centers with higher interventions/year (OR: p = 0.019), and by respondents with less experience in cardiology (ICU: p = 0.046). CONCLUSION: Variability in the use of PACs and echocardiography was found. Protocols regulating the use of PACs seem infrequent. University centers use PACs less and have greater skills in TEE. Training and certifications in echocardiography should be encouraged.

13.
J Cardiothorac Vasc Anesth ; 38(8): 1673-1682, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38862285

RESUMO

OBJECTIVE: Right ventricular (RV) dysfunction in cardiac surgery can lead to RV failure, which is associated with increased morbidity and mortality. Abnormal RV function can be identified using RV pressure monitoring. The primary objective of the study is to determine the proportion of patients with abnormal RV early to end-diastole diastolic pressure gradient (RVDPG) and abnormal RV end-diastolic pressure (RVEDP) before initiation and after cardiopulmonary bypass (CPB) separation. The secondary objective is to evaluate if RVDPG before CPB initiation is associated with difficult and complex separation from CPB, RV dysfunction, and failure at the end of cardiac surgery. DESIGN: Prospective study. SETTING: Tertiary care cardiac institute. PARTICIPANTS: Cardiac surgical patients. INTERVENTION: Cardiac surgery. MEASUREMENTS AND MAIN RESULTS: Automated electronic quantification of RVDPG and RVEDP were obtained. Hemodynamic measurements were correlated with cardiac and extracardiac parameters from transesophageal echocardiography and postoperative complications. Abnormal RVDPG was present in 80% of the patients (n = 105) at baseline, with a mean RVEDP of 14.2 ± 3.9 mmHg. Patients experienced an RVDPG > 4 mmHg for a median duration of 50.2% of the intraoperative period before CPB initiation and 60.6% after CPB separation. A total of 46 (43.8%) patients had difficult/complex separation from CPB, 18 (38.3%) patients had RV dysfunction, and 8 (17%) had RV failure. Abnormal RVDPG before CPB was not associated with postoperative outcome. CONCLUSION: Elevated RVDPG and RVEDP are common in cardiac surgery. RVDPG and RVEDP before CPB initiation are not associated with RV dysfunction and failure but can be used to diagnose them.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Monitorização Intraoperatória , Disfunção Ventricular Direita , Humanos , Masculino , Estudos Prospectivos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Idoso , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Pressão Ventricular/fisiologia , Ponte Cardiopulmonar/métodos , Ponte Cardiopulmonar/efeitos adversos , Função Ventricular Direita/fisiologia , Ecocardiografia Transesofagiana/métodos
14.
Perfusion ; 39(1_suppl): 49S-65S, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38654449

RESUMO

During veno-venous extracorporeal membrane oxygenation (V-V ECMO), blood is drained from the central venous circulation to be oxygenated and decarbonated by an artificial lung. It is then reinfused into the right heart and pulmonary circulation where further gas-exchange occurs. Each of these steps is characterized by a peculiar physiology that this manuscript analyses, with the aim of providing bedside tools for clinical care: we begin by describing the factors that affect the efficiency of blood drainage, such as patient and cannulae position, fluid status, cardiac output and ventilatory strategies. We then dig into the complexity of extracorporeal gas-exchange, with particular reference to the effects of extracorporeal blood-flow (ECBF), fraction of delivered oxygen (FdO2) and sweep gas-flow (SGF) on oxygenation and decarbonation. Subsequently, we focus on the reinfusion of arterialized blood into the right heart, highlighting the effects on recirculation and, more importantly, on right ventricular function. The importance and challenges of haemodynamic monitoring during V-V ECMO are also analysed. Finally, we detail the interdependence between extracorporeal circulation, native lung function and mechanical ventilation in providing adequate arterial blood gases while allowing lung rest. In the absence of evidence-based strategies to care for this particular group of patients, clinical practice is underpinned by a sound knowledge of the intricate physiology of V-V ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Hemodinâmica/fisiologia
15.
J Clin Ultrasound ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38742373

RESUMO

In the last few years prone positioning has been used increasingly in the treatment of patients with acute respiratory distress syndrome and this maneuver is now considered a simple and safe method to improve oxygenation. Hemodynamic monitoring by echocardiography may be required but prone positioning imposes certain challenges limiting standard examination. The article describes the application of the "trans-splenic retrocardiac view," a little-known echographic window for obtaining Doppler parameters from the back in prone-positioned patients.

16.
J Clin Monit Comput ; 38(2): 325-335, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38112879

RESUMO

PURPOSE: Intraoperative hypotension (IOH) is associated with adverse outcomes. We therefore explored beliefs regarding IOH and barriers to its treatment. Secondarily, we assessed if an educational intervention and mandated mean arterial pressure (MAP), or the implementation of the Hypotension Prediction Index-software (HPI) were associated with a reduction in IOH. METHODS: Structured interviews (n = 27) and questionnaires (n = 84) were conducted to explore clinicians' beliefs and barriers to IOH treatment, in addition to usefulness of HPI questionnaires (n = 14). 150 elective major surgical patients who required invasive blood pressure monitoring were included in three cohorts to assess incidence and time-weighted average (TWA) of hypotension (MAP < 65 mmHg). Cohort one received standard care (baseline), the clinicians of cohort two had a training on hypotension and a mandated MAP > 65 mmHg, and patients of the third cohort received protocolized care using the HPI. RESULTS: Clinicians felt challenged to manage IOH in some patients, yet they reported sufficient knowledge and skills. HPI-software was considered useful and beneficial. No difference was found in incidence of IOH between cohorts. TWA was comparable between baseline and education cohort (0.15 mmHg [0.05-0.41] vs. 0.11 mmHg [0.02-0.37]), but was significantly lower in the HPI cohort (0.04 mmHg [0.00 to 0.11], p < 0.05 compared to both). CONCLUSIONS: Clinicians believed they had sufficient knowledge and skills, which could explain why no difference was found after the educational intervention. In the HPI cohort, IOH was significantly reduced compared to baseline, therefore HPI-software may help prevent IOH. TRIAL REGISTRATION: ISRCTN 17,085,700 on May 9th, 2019.


Assuntos
Hipotensão , Complicações Intraoperatórias , Humanos , Pressão Sanguínea , Estudos de Coortes , Complicações Intraoperatórias/epidemiologia , Hipotensão/etiologia , Software
17.
J Clin Monit Comput ; 38(2): 469-477, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38252193

RESUMO

The difference between venous and arterial carbon dioxide pressure (pCO2 gap), has been used as a diagnostic and prognostic tool. We aimed to assess whether perioperative pCO2 gaps can predict postoperative complications. This was a secondary analysis of a multicenter RCT comparing goal-directed therapy (GDT) to standard care in which 464 patients undergoing high-risk elective abdominal surgery were included. Arterial and central venous blood samples were simultaneously obtained at four time points: after induction, at the end of surgery, at PACU/ICU admission, and PACU/ICU discharge. Complications within the first 30 days after surgery were recorded. Similar pCO2 gaps were found in patients with and without complications, except for the pCO2 gap at the end of surgery, which was higher in patients with complications (6.0 mmHg [5.0-8.0] vs. 6.0 mmHg [4.1-7.5], p = 0.005). The area under receiver operating characteristics curves for predicting complications from pCO2 gaps at all time points were between 0.5 and 0.6. A weak correlation between ScvO2 and pCO2 gaps was found for all timepoints (ρ was between - 0.40 and - 0.29 for all timepoints, p < 0.001). The pCO2 gap did not differ between GDT and standard care at any of the selected time points. In our study, pCO2 gap was a poor predictor of major postoperative complications at all selected time points. Our research does not support the use of pCO2 gap as a prognostic tool after high-risk abdominal surgery. pCO2 gaps were comparable between GDT and standard care. Clinical trial registration Netherlands Trial Registry NTR3380.


Assuntos
Objetivos , Complicações Pós-Operatórias , Humanos , Complicações Pós-Operatórias/diagnóstico , Abdome/cirurgia , Prognóstico , Pressão Arterial
18.
J Clin Monit Comput ; 38(2): 281-291, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38280975

RESUMO

We have developed a method to automatically assess LV function by measuring mitral annular plane systolic excursion (MAPSE) using artificial intelligence and transesophageal echocardiography (autoMAPSE). Our aim was to evaluate autoMAPSE as an automatic tool for rapid and quantitative assessment of LV function in critical care patients. In this retrospective study, we studied 40 critical care patients immediately after cardiac surgery. First, we recorded a set of echocardiographic data, consisting of three consecutive beats of midesophageal two- and four-chamber views. We then altered the patient's hemodynamics by positioning them in anti-Trendelenburg and repeated the recordings. We measured MAPSE manually and used autoMAPSE in all available heartbeats and in four LV walls. To assess the agreement with manual measurements, we used a modified Bland-Altman analysis. To assess the precision of each method, we calculated the least significant change (LSC). Finally, to assess trending ability, we calculated the concordance rates using a four-quadrant plot. We found that autoMAPSE measured MAPSE in almost every set of two- and four-chamber views (feasibility 95%). It took less than a second to measure and average MAPSE over three heartbeats. AutoMAPSE had a low bias (0.4 mm) and acceptable limits of agreement (- 3.7 to 4.5 mm). AutoMAPSE was more precise than manual measurements if it averaged more heartbeats. AutoMAPSE had acceptable trending ability (concordance rate 81%) during hemodynamic alterations. In conclusion, autoMAPSE is feasible as an automatic tool for rapid and quantitative assessment of LV function, indicating its potential for hemodynamic monitoring.


Assuntos
Monitorização Hemodinâmica , Disfunção Ventricular Esquerda , Humanos , Função Ventricular Esquerda , Ecocardiografia Transesofagiana , Disfunção Ventricular Esquerda/diagnóstico por imagem , Estudos Retrospectivos , Inteligência Artificial , Valva Mitral/diagnóstico por imagem
19.
J Clin Monit Comput ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758404

RESUMO

Intraoperative hypotension is common and associated with organ injury. Hypotension can not only occur during surgery, but also thereafter. After surgery, most patients are treated in post-anesthesia care units (PACU). The incidence of PACU hypotension is largely unknown - presumably in part because arterial pressure is usually monitored intermittently in PACU patients. We therefore aimed to evaluate the incidence, duration, and severity of PACU hypotension in low-risk patients recovering from non-cardiac surgery. In this observational study, we performed blinded continuous non-invasive arterial pressure monitoring with finger-cuffs (ClearSight system; Edwards Lifesciences, Irvine, CA, USA) in 100 patients recovering from non-cardiac surgery in the PACU. We defined PACU hypotension as a mean arterial pressure (MAP) < 65 mmHg. Patients had continuous finger-cuff monitoring for a median (25th percentile, 75th percentile) of 64 (44 to 91) minutes. Only three patients (3%) had PACU hypotension for at least one consecutive minute. These three patients had 4, 4, and 2 cumulative minutes of PACU hypotension; areas under a MAP of 65 mmHg of 17, 9, and 9 mmHg x minute; and time-weighted averages MAP less than 65 mmHg of 0.5, 0.3, and 0.2 mmHg. The median volume of crystalloid fluid patients were given during PACU treatment was 200 (100 to 400) ml. None was given colloids or a vasopressor during PACU treatment. In low-risk patients recovering from non-cardiac surgery, the incidence of PACU hypotension was very low and the few episodes of PACU hypotension were short and of modest severity.

20.
J Clin Monit Comput ; 38(1): 57-67, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37968547

RESUMO

Pulse pressure variation (PPV) is a well-established method for predicting fluid responsiveness in mechanically ventilated patients. The predictive accuracy is, however, disputed for ventilation with low tidal volume (VT) or low heart-rate-to-respiratory-rate ratio (HR/RR). We investigated the effects of VT and RR on PPV and on PPV's ability to predict fluid responsiveness. We included patients scheduled for open abdominal surgery. Prior to a 250 ml fluid bolus, we ventilated patients with combinations of VT from 4 to 10 ml kg-1 and RR from 10 to 31 min-1. For each of 10 RR-VT combinations, PPV was derived using both a classic approach and a generalized additive model (GAM) approach. The stroke volume (SV) response to fluid was evaluated using uncalibrated pulse contour analysis. An SV increase > 10% defined fluid responsiveness. Fifty of 52 included patients received a fluid bolus. Ten were fluid responders. For all ventilator settings, fluid responsiveness prediction with PPV was inconclusive with point estimates for the area under the receiver operating characteristics curve between 0.62 and 0.82. Both PPV measures were nearly proportional to VT. Higher RR was associated with lower PPV. Classically derived PPV was affected more by RR than GAM-derived PPV. Correcting PPV for VT could improve PPV's predictive utility. Low HR/RR has limited effect on GAM-derived PPV, indicating that the low HR/RR limitation is related to how PPV is calculated. We did not demonstrate any benefit of GAM-derived PPV in predicting fluid responsiveness.Trial registration: ClinicalTrials.gov, reg. March 6, 2020, NCT04298931.


Assuntos
Hidratação , Taxa Respiratória , Humanos , Pressão Sanguínea/fisiologia , Volume de Ventilação Pulmonar , Hidratação/métodos , Volume Sistólico/fisiologia , Pulmão , Respiração Artificial/métodos , Hemodinâmica/fisiologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa