Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Nano Lett ; 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38525903

RESUMO

The c-axis piezoresistivity is a fundamental and important parameter of graphite, but its value near zero pressure has not been well determined. Herein, a new method for studying the c-axis piezoresistivity of van der Waals materials near zero pressure is developed on the basis of in situ scanning electron microscopy and finite element simulation. The c-axis piezoresistivity of microscale highly oriented pyrolytic graphite (HOPG) is found to show a large value of 5.68 × 10-5 kPa-1 near zero pressure and decreases by 2 orders of magnitude to the established value of ∼10-7 kPa-1 when the pressure increases to 200 MPa. By modulating the serial tunneling barrier model on the basis of the stacking faults, we describe the c-axis electrical transport of HOPG under compression. The large c-axis piezoresistivity near zero pressure and its large decrease in magnitude with pressure are attributed to the rapid stiffening of the electromechanical properties under compression.

2.
Nano Lett ; 24(10): 3112-3117, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38416575

RESUMO

Grain boundary (GB) fracture is a major mechanism of material failure in polycrystalline ceramics. However, the intricate atomic arrangements of GBs have impeded our understanding of the atomistic mechanisms of these processes. In this study, we investigated the atomic-scale crack propagation behavior of an α-Al2O3 ∑13 grain boundary, using a combination of in situ transmission electron microscopy (TEM) and scanning TEM. The atomic-scale fracture path along the GB core was directly determined by the observation of the atomic structures of the fractured surfaces, which is consistent with density functional theory calculations. We found that the GB fracture can be attributed to the weaker local bonds and a smaller number of bonds along the fracture path. Our findings provide atomistic insights into the mechanisms of crack propagation along GBs, offering significant implications for GB engineering and the toughening of ceramics.

3.
Acta Neurochir (Wien) ; 166(1): 343, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39167233

RESUMO

BACKGROUND: The intraoperative differentiation between tumour tissue, healthy brain tissue, and any sensitive structure of the central nervous system is carried out in modern neurosurgery using various multimodal technologies such as neuronavigation, fluorescent dyes, intraoperative ultrasound or the use of intraoperative MRI, but also the haptic experience of the neurosurgeon. Supporting the surgeon by developing instruments with integrated haptics could provide a further objective dimension in the intraoperative recognition of healthy and diseased tissue. METHODS: In this study, we describe intraoperative mechanical indentation measurements of human brain tissue samples of different tumours taken during neurosurgical operation and measured directly in the operating theatre, in a time frame of maximum five minutes. We present an overview of the Young's modulus for the different brain tumour entities and potentially differentiation between them. RESULTS: We examined 238 samples of 75 tumour removals. Neither a clear distinction of tumour tissue against healthy brain tissue, nor differentiation of different tumour entities was possible on solely the Young's modulus. Correlation between the stiffness grading of the surgeon and our measurements could be found. CONCLUSION: The mechanical behaviour of brain tumours given by the measured Young's modulus corresponds well to the stiffness assessment of the neurosurgeon and can be a great tool for further information on mechanical characteristics of brain tumour tissue. Nevertheless, our findings imply that the information gained through indentation is limited.


Assuntos
Neoplasias Encefálicas , Módulo de Elasticidade , Procedimentos Neurocirúrgicos , Humanos , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Procedimentos Neurocirúrgicos/métodos , Encéfalo/cirurgia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia
4.
J Non Cryst Solids ; 6262024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38314066

RESUMO

This paper lays out best practices for evaluating and optimizing a Raman spectroscopy setup to ensure the collection of reliable spectral data and/or Raman images on indented glasses. The Raman spectroscopic measurements and imaging were conducted on residual imprints created with Berkovich and spherical probes at forces in the sub-newton range in fused silica. The capability of a conventional optical instrument for mapping spectral variations in sub-newton imprints on glasses is evaluated by studying the influence of the optical configuration (choice of microscope objective) on the spatial resolution of the spectroscopy setup. The spatial resolution was quantitatively assessed in Z profile measurements and qualitatively evaluated by mapping changes in spectral features and correlated densification within the indented regions of fused silica specimens. The paper discusses the importance of appropriately matching the analysis volume of the Raman spectroscopic setup with the size of the indentation-induced densification zone by demonstrating the detrimental effects a mismatch may have on accurately capturing the magnitude of spectral changes and correlated densification.

5.
Entropy (Basel) ; 26(4)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38667894

RESUMO

In order to find more excellent structural materials resistant to radiation damage, high-entropy alloys (HEAs) have been developed due to their characteristics of limited point defect diffusion such as lattice distortion and slow diffusion. Specially, refractory high-entropy alloys (RHEAs) that can adapt to a high-temperature environment are badly needed. In this study, TiZrHfNbMo0.1 RHEAs are selected for irradiation and nanoindentation experiments. We combined the mechanistic model for the depth-dependent hardness of ion-irradiated metals and the introduction of the scale factor f to modify the irradiation-hardening model in order to better describe the nanoindentation indentation process in the irradiated layer. Finally, it can be found that, with the increase in irradiation dose, a more serious lattice distortion caused by a higher defect density limits the expansion of the plastic zone.

6.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(3): 469-475, 2024 Jun 25.
Artigo em Chinês | MEDLINE | ID: mdl-38932532

RESUMO

Accurately evaluating the local biomechanics of arterial wall is crucial for diagnosing and treating arterial diseases. Indentation measurement can be used to evaluate the local mechanical properties of the artery. However, the effects of the indenter's geometric structure and the analysis theory on measurement results remain uncertain. In this paper, four kinds of indenters were used to measure the pulmonary aorta, the proximal thoracic aorta and the distal thoracic aorta in pigs, and the arterial elastic modulus was calculated by Sneddon and Sirghi theory to explore the influence of the indenter geometry and analysis theory on the measured elastic modulus. The results showed that the arterial elastic modulus measured by cylindrical indenter was lower than that measured by spherical indenter. In addition, compared with the calculated results of Sirghi theory, the Sneddon theory, which does not take adhesion forces in account, resulted in slightly larger elastic modulus values. In conclusion, this study provides parametric support for effective measurement of arterial local mechanical properties by millimeter indentation technique.


Assuntos
Aorta Torácica , Módulo de Elasticidade , Artéria Pulmonar , Animais , Suínos , Fenômenos Biomecânicos , Aorta Torácica/fisiologia , Aorta Torácica/anatomia & histologia , Artéria Pulmonar/fisiologia , Estresse Mecânico , Artérias/fisiologia
7.
Cartilage ; : 19476035241235633, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38501455

RESUMO

OBJECTIVE: To investigate whether and how a single traumatic impact changes the mechanical properties of talar articular cartilage. DESIGN: A marble was placed on the joint surface and a weight was dropped on both medial and lateral caprine talus to create a well-defined single focal impact. The mechanical properties of intact and impacted talar cartilage were measured with a micro-indenter. Elastic (storage) and viscous (loss) moduli were determined by oscillatory ramp and dynamic mechanical analysis protocols. RESULTS: We found significant differences between ankles and within the same ankle joint, with the medial talus having significantly higher storage- and loss moduli than the lateral talus. The storage- and loss moduli of intact articular cartilage increased with greater indentation depths. However, postimpact the storage- and loss moduli were significantly and consistently lower in all specimens indicating immediate posttraumatic damage. The deeper regions of talar cartilage were less affected by the impact than the more superficial regions. CONCLUSIONS: A single traumatic impact results in an immediate and significant decrease of storage- and loss moduli. Further research must focus on the development of non- or minimally invasive diagnostic tools to address the exact microdamage caused by the impact. We speculate that the traumatic impact damaged the collagen fibers that confine the water-binding proteoglycans and thereby decreasing the hydrostatic pressure of cartilage. As part of the treatment directly after a trauma, one could imagine a reduction or restriction of peak loads to prevent the progression of the cascade towards PTOA of the ankle joint.

8.
J Bone Miner Res ; 39(8): 1120-1131, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-38887013

RESUMO

Knee osteoarthritis (OA), characterized by multiple joint tissue degenerations, remains a significant clinical challenge. Recent evidence suggests that crosstalk within the osteochondral unit may drive OA progression. Although structural-biomechanical properties of bone and cartilage have been studied, potential interaction within the osteochondral unit in the context of OA has yet to be investigated. We performed comprehensive structural and biomechanical quantification of the cartilage, subchondral bone plate (SBP), and subchondral trabecular bone (STB) using 101 osteochondral cores collected from tibial plateaus of 12 control human cadavers (CT, 5 male/7 female) and 19 patients undergoing total knee replacement (OA, 6 male/13 female). For each sample, we quantified SBP microstructure, plate-and-rod morphological properties of the STB using individual trabecula segmentation, and morphological and compositional properties of the articular cartilage. We also performed indentation testing on each compartment of the osteochondral unit to extract the respective structural-mechanical properties. Cartilage thickness was lower in moderate and severe OA regions, while Osteoarthritis Research Society International score was higher only in severe OA regions. GAG content did not change in any OA region. Aggregate and shear moduli were lower only in severe OA regions, while permeability was lower only in moderate OA regions. In the SBP, thickness and tissue mineral density were higher in moderate and severe OA regions. Tissue modulus of STB was lower in moderate OA regions despite a thicker and more mineralized SBP; this deterioration was not observed in severe OA regions. Regression analysis revealed strong correlations between cartilage and STB properties in CT; these correlations were also found in moderate OA regions but were not observed in severe OA regions. In summary, our findings comprehensively characterize the human OA osteochondral unit. Importantly, uncoupling cartilage and subchondral bone structural-mechanical properties may be a hallmark of OA.


Knee osteoarthritis (OA) is a complex condition involving the degradation of joint tissues. To better understand OA progression, we investigated the interplay between different components of the joint. Our study focused on how cartilage, subchondral bone plate (SBP), and subchondral trabecular bone (STB) interact in human knee OA samples. We observed distinct changes in these tissues in moderate and severe OA regions compared with healthy joints. In moderate to severe OA, we found that cartilage thickness decreased, while the SBP thickened. Interestingly, the strength of the STB decreased only in moderate OA regions, not in severe OA. Moreover, our analysis revealed strong correlations between cartilage and STB properties in healthy joints and moderate OA regions. However, these correlations were absent in severe OA regions, indicating a disruption in the usual relationship between these tissues. Overall, our findings shed light on the structural and biomechanical changes occurring within the knee joint in OA. Understanding these changes may offer insights into potential therapeutic strategies for managing OA.


Assuntos
Cartilagem Articular , Osteoartrite do Joelho , Humanos , Cartilagem Articular/patologia , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/fisiopatologia , Masculino , Feminino , Osteoartrite do Joelho/patologia , Osteoartrite do Joelho/fisiopatologia , Idoso , Fenômenos Biomecânicos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Osso Esponjoso/patologia , Osso Esponjoso/diagnóstico por imagem , Osso Esponjoso/fisiopatologia
9.
Micromachines (Basel) ; 15(4)2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38675243

RESUMO

Cell models play a crucial role in analyzing the mechanical response of cells and quantifying cellular damage incurred during micromanipulation. While traditional models can capture the overall mechanical behavior of cells, they often lack the ability to discern among distinct cellular components. Consequently, by employing dissipative particle dynamics, this study constructed a triangular network-like representation of the cell membrane along with cross-linked cytoskeletal chains. The mechanical properties of both the membrane and cytoskeleton were then analyzed through a series of simulated mechanical tests, validated against real-world experiments. The investigation utilized particle-tracking rheology to monitor changes in the mean square displacements of membrane particles over time, facilitating the analysis of the membrane's storage and loss moduli. Additionally, the cytoskeletal network's storage and loss moduli were examined via a double-plate oscillatory shear experiment. The simulation results revealed that both the membrane and cytoskeleton exhibit viscoelastic behavior, as evidenced by the power-law dependency of their storage and loss moduli on frequency. Furthermore, indentation and microinjection simulations were conducted to examine the overall mechanical properties of cells. In the indentation experiments, an increase in the shear modulus of the membrane's WLCs correlated with a higher Young's modulus for the entire cell. Regarding the microinjection experiment, augmenting the microinjection speed resulted in reduced deformation of the cell at the point of membrane rupture and a lower percentage of high strain.

10.
Small Methods ; : e2400251, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38607949

RESUMO

The advent of biomedical applications of soft bioinspired materials has entailed an increasing demand for streamlined and expedient characterization methods meant for both research and quality control objectives. Here, a novel measurement system for the characterization of biological hydrogels with volumes as low as 75 µL was developed. The system is based on an indentation platform equipped with micrometer drive actuators that allow the determination of both the fracture points and Young's moduli of relatively stiff polymers, including agarose, as well as the measurements of viscosity for exceptionally soft and viscous hydrogels, such as DNA hydrogels. The sensitivity of the method allows differentiation between DNA hydrogels produced by rolling circle amplification based on different template sequences and synthesis protocols. In addition, the polymerization kinetics of the hydrogels can be determined by time-resolved measurements, and the apparent viscosities of even more complex DNA-based nanocomposites can be measured. The platform presented here thus offers the possibility to characterize a broad variety of soft biomaterials in a targeted, fast, and cost-effective manner, holding promises for applications in fundamental materials science and ensuring reproducibility in the handling of complex materials.

11.
J Dent Res ; 103(4): 419-426, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38410925

RESUMO

The ever-increasing usage of ceramic materials in restorative dentistry necessitates a simple and effective method to evaluate flexural strength σF and fracture toughness KC. We propose a novel method to determine these quantities using a bilayer specimen composed of a brittle plate adhesively bonded onto a transparent polycarbonate substrate. When this bilayer structure is placed under spherical indentation, tunneling radial cracks initiate and propagate in the lower surface of the brittle layer. The failure analysis is based on previous theoretical relationships, which correlate σF with the indentation force P and layer thickness d, and KC with P and mean length of radial cracks. This work examines the accuracy and limitations of this approach using a wide range of contemporary dental ceramic materials. The effect of layer thickness, indenter radius, load level, and length and number of radial cracks are carefully examined. The accuracy of the predicted σF and KC is similar to those obtained with other concurrent test methods, such as biaxial flexure and 3-point bending (σF), and bending specimens with crack-initiation flaws (KC). The benefits of the present approach include treatment for small and thin plates, elimination of the need to introduce a precrack, and avoidance of dealing with local material nonlinearity effects for the KC measurements. Finally, the bilayer configuration resembles occlusal loading of a ceramic restoration (brittle layer) bonded to a posterior tooth (compliant substrate).


Assuntos
Cerâmica , Dente , Teste de Materiais , Cerâmica/química , Odontologia , Porcelana Dentária , Propriedades de Superfície
12.
J Hand Surg Eur Vol ; : 17531934241249919, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780046

RESUMO

Total wrist arthroplasty (TWA) aims to restore pain-free motion to diseased joints. One such TWA, the Motec, has demonstrated good results with acceptable complication rates. It has recently been suggested that the metal-on-carbon fibre reinforced poly ether ether ketone (Mo-CFR-PEEK) version of the Motec TWA be implanted instead of the metal-on-metal version. An explant analysis was undertaken on seven Motec Mo-CFR-PEEK TWAs, revised for a variety of reasons, after a mean time of 2 years in vivo. Compared to a new Motec implant, five of the explanted metal heads and three of the CFR-PEEK cups became smoother in vivo, suggesting self-polishing and negative skewness, indicating some material loss in vivo. Two explanted cups showed indentation marks on their rims and one of these was from component impingement with embedded metallic debris. In the short-term, the articulating surfaces of Motec Mo-CFR-PEEK TWAs did not show major damage.Level of evidence: IV.

13.
Materials (Basel) ; 17(12)2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38930387

RESUMO

A new unloading contact model of an elastic-perfectly plastic half-space indented by an elastic spherical indenter is presented analytically. The recovered deformation of the elastic indenter and the indented half-space has been found to be dependent on the elastic modulus ratio after fully unloading. The recovered deformation of the indented half-space can be calculated based on the deformation of the purely elastic indenter. The unloading process is assumed to be entirely elastic, and then the relationship of contact force and indentation can be determined based on the solved recovered deformation and conforms to Hertzian-type. The model can accurately predict the residual indentation and residual curvature radius after fully unloading. Numerical simulations are performed to demonstrate the assumptions and the unloading model. The proposed unloading model can cover a wide range of indentations and material properties and is compared with existing unloading models. The cyclic behavior including loading and unloading can be predicted by combining the proposed unloading law with the existing contact loading model. The combined model can be employed for low-velocity impact and nanoindentation tests and the comparison results are in good agreement.

14.
Polymers (Basel) ; 16(13)2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-39000657

RESUMO

The investigation of damage development is essential for the design and optimization of hybrid structures. This paper provides a reference for the structural design of brittle-ductile hybrid LVI-resistant laminates through analyzing the damage development mechanism of carbon/Kevlar fabric-reinforced composite laminates. The effects of Kevlar fabric hybrid ply and intercalation on the damage development of carbon/Kevlar composite laminates under low-velocity impact (LVI) were investigated using quasi-static indentation (QSI). It was found that an increase in the Kevlar hybrid ratio significantly reduced the peak load and stiffness of these laminates (the maximum decreases in strength and stiffness were 46.03% and 41.43%, respectively), while laminates with identical hybrid ratios but different plying configurations maintained a comparable stiffness under QSI, with differences of less than 5%. Interestingly, Kevlar fibers exhibited irregular fractures as the yarn was splitting, while carbon fibers presented neat breaks, which indicated material-specific failure modes. Notably, the introduction of Kevlar hybridization beyond pure Kevlar configurations (KKKK) resulted in a decrease in the percentage of fiber damage (CCCC, CCCK, CCKK, and KCCK accounted for 80%, 79.8%, 70%, and 60% of fiber damage, respectively), attributed to an increase in resin cracks and lower levels of Kevlar yarn breakage. The internal damage diameter of specimens was accurately predicted from the diameter of visible damage on the QSI surface. Compared with CCCC and CCKK setups, which are affected by resin cracks formed via the carbon surface on the loading side propagating along the yarn direction (including the yarn settling direction), KCCK demonstrated less delamination between the first and second ply.

15.
JBMR Plus ; 8(2): ziad012, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38505533

RESUMO

The fracture behavior of bone is critically important for evaluating its mechanical competence and ability to resist fractures. Fracture toughness is an intrinsic material property that quantifies a material's ability to withstand crack propagation under controlled conditions. However, properly conducting fracture toughness testing requires the access to calibrated mechanical load frames and the destructive testing of bone samples, and therefore fracture toughness tests are clinically impractical. Impact microindentation mimicks certain aspects of fracture toughness measurements, but its relationship with fracture toughness remains unknown. In this study, we aimed to compare measurements of notched fracture toughness and impact microindentation in fresh and boiled bovine bone. Skeletally mature bovine bone specimens (n = 48) were prepared, and half of them were boiled to denature the organic matrix, while the other half remained preserved in frozen conditions. All samples underwent a notched fracture toughness test to determine their resistance to crack initiation (KIC) and an impact microindentation test using the OsteoProbe to obtain the Bone Material Strength index (BMSi). Boiling the bone samples increased the denatured collagen content, while mineral density and porosity remained unaffected. The boiled bones also showed significant reduction in both KIC (P < .0001) and the average BMSi (P < .0001), leading to impaired resistance of bone to crack propagation. Remarkably, the average BMSi exhibited a high correlation with KIC (r = 0.86; P < .001). A ranked order difference analysis confirmed the excellent agreement between the 2 measures. This study provides the first evidence that impact microindentation could serve as a surrogate measure for bone fracture behavior. The potential of impact microindentation to assess bone fracture resistance with minimal sample disruption could offer valuable insights into bone health without the need for cumbersome testing equipment and sample destruction.

16.
ACS Biomater Sci Eng ; 10(2): 838-850, 2024 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-38178628

RESUMO

The development of remote surgery hinges on comprehending the mechanical properties of the tissue at the surgical site. Understanding the mechanical behavior of the medulla oblongata tissue is instrumental for precisely determining the remote surgery implementation site. Additionally, exploring this tissue's response under electric fields can inform the creation of electrical stimulation therapy regimens. This could potentially reduce the extent of medulla oblongata tissue damage from mechanical compression. Various types of pulsed electric fields were integrated into a custom-built indentation device for this study. Experimental findings suggested that applying pulsed electric fields amplified the shear modulus of the medulla oblongata tissue. In the electric field, the elasticity and viscosity of the tissue increased. The most significant influence was noted from the low-frequency pulsed electric field, while the burst pulsed electric field had a minimal impact. At the microstructural scale, the application of an electric field led to the concentration of myelin in areas distant from the surface layer in the medulla oblongata, and the orderly structure of proteoglycans became disordered. The alterations observed in the myelin and proteoglycans under an electric field were considered to be the fundamental causes of the changes in the mechanical behavior of the medulla oblongata tissue. Moreover, cell polarization and extracellular matrix cavitation were observed, with transmission electron microscopy results pointing to laminar separation within the myelin at the ultrastructure scale. This study thoroughly explored the impact of electric field application on the mechanical behavior and microstructure of the medulla oblongata tissue, delving into the underlying mechanisms. This investigation delved into the changes and mechanisms in the mechanical behavior and microstructure of medulla oblongata tissue under the influence of electric fields. Furthermore, this study could serve as a reference for the development of electrical stimulation regimens in the central nervous system. The acquired mechanical behavior data could provide valuable baseline information to aid in the evolution of remote surgery techniques involving the medulla oblongata tissue.


Assuntos
Bulbo , Proteoglicanas , Bulbo/fisiologia , Estimulação Elétrica , Proteoglicanas/farmacologia
17.
Front Bioeng Biotechnol ; 12: 1353418, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38712331

RESUMO

Patients with scars face a grave threat to their mental and physical health. Negative pressure has been used for scar therapy in medical care and provides a microenvironment conducive to scar healing while stimulating cell regeneration. Negative pressure may disrupt scar tissue regeneration when the pressure is too high or too low, so finding a suitable negative pressure is important. We hypothesized that different negative pressure magnitudes would affect scar tissue properties differently. This research aimed to provide practical recommendations for scar therapy. This study used three negative pressures (-105 mmHg, -125 mmHg, and -145 mmHg) to compare scar material properties. We measured scar tissue thickness and viscoelasticity with a motor-driven ultrasound indentation system. According to the results of this study, scar thickness is most effectively reduced at a negative pressure of -105 mmHg. In comparison, scar viscoelasticity continuously increases at a negative pressure of -125 mmHg. Negative pressure therapy can be recommended to scar care clinics based on the results of this study.

18.
Microsc Res Tech ; 87(1): 105-113, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37680055

RESUMO

Reliable reconstruction of AFM tip geometry is not an easy task. The shape of the tip can be (partially) reconstructed from the AFM image of a calibration sample using a blind reconstruction method. The result is a range of the tip shapes (from unrealistically sharp to blunt). A criterion for selecting the true shape is proposed. It is based on reconstruction of the calibration relief. Further refining the probe geometry by indenting an elastic polymer is discussed. The choice of the test sample is another problem. In practice, the researcher has a small number of commercially available test gratings. Their limitations are highlighted. An approximation of tip geometry by a body of revolution is required in indentation experiments. A hyperboloid was found to be the closest approximation to the conventional probes. The contact area was obtained for the hyperboloids with different parameters indenting an elastic material. RESEARCH HIGHLIGHTS: Criteria for blind reconstruction algorithm of AFM tip shape. Pros and cons of tip shape calibration samples. Contact area of the elastic indentation by hyperbolic indenter.

19.
Materials (Basel) ; 17(14)2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-39063727

RESUMO

Large forgings are crucial in aerospace applications; however, the residual stresses generated during their forming and heat treatment seriously affect their serviceability. Therefore, the non-destructive detection of residual stresses in large forgings is of far-reaching significance for ensuring the quality of forgings and realising precision machining. Although a variety of detection methods are available, there is still a lack of a programme that can comprehensively, accurately and non-destructively measure the residual stresses in large forgings. This study is dedicated to exploring the application of the bouncing impact indentation method in the non-destructive testing of residual stresses in large forgings. Through in-depth finite element simulations and orthogonal scheme analyses, we found that the elastic modulus, yield strength and work hardening indexes have significant effects on the impact indentation process. Further, we establish the dimensionless function of residual stress and indentation parameters, and successfully obtain the inversion algorithm of residual stress. The relative error of the calculated values of the indentation curves hm and hr in the simulation with reference values is not more than 3%, and the relative error of the corrected Pm inversion values for most virtual materials is not more than 5%. The folding elastic modulus and apparent elastic modulus obtained by inversion are controlled within 10%, which demonstrates a high value for engineering applications. In addition, we innovatively express the research results in the form of 3D stress diagrams, realising the digital expression of 3D residual stresses in large forgings based on feature point measurements and contour surface configurations, which provides intuitive and comprehensive data support for engineering practice.

20.
J Mech Behav Biomed Mater ; 155: 106572, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38754153

RESUMO

The personalisation of finite element models is an important problem in the biomechanical fields where subject-specific analyses are fundamental, particularly in studying soft tissue mechanics. The personalisation includes the choice of the constitutive law of the model's material, as well as the choice of the material parameters. In vivo identification of the material properties of soft tissues is challenging considering the complex behaviour of soft tissues that are, among other things, non-linear hyperelastic and heterogeneous. Hybrid experimental-numerical methods combining in vivo indentations and inverse finite element analyses are common to identify these material parameters. Yet, the uniqueness and the uncertainty of the multi-material hyperelastic model have not been evaluated. This study presents a sensitivity analysis performed on synthetic indentation data to investigate the identification uncertainties of the material parameters in a bi-material thigh phantom. Synthetic numerical data, used to replace experimental measurements, considered several measurement modalities: indenter force and displacement, stereo-camera 3D digital image correlation of the indented surface, and ultrasound B-mode images. A finite element model of the indentation was designed with either Ogden-Moerman or Mooney-Rivlin constitutive laws for both materials. The parameters' identifiability (i.e. the possibility of converging to a unique parameter set within an acceptable margin of error) was assessed with various cost functions formulated using the different synthetic data sets. The results underline the need for multiple experimental modalities to reduce the uncertainty of the identified parameters. Additionally, the experimental error can impede the identification of a unique parameter set, and the cost function depends on the constitutive law. This study highlights the need for sensitivity analyses before the design of the experimental protocol. Such studies can also be used to define the acceptable range of errors in the experimental measurement. Eventually, the impact of the evaluated uncertainty of the identified parameters should be further investigated according to the purpose of the finite element modelling.


Assuntos
Análise de Elementos Finitos , Teste de Materiais , Fenômenos Biomecânicos , Fenômenos Mecânicos , Testes Mecânicos , Elasticidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa