Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Biochem ; 686: 115428, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38103628

RESUMO

Ultrasensitive detection of circulating tumor cells (CTCs) holds significant clinical importance in monitoring metastasis and therapeutic outcomes. In this study, we have developed a novel electrochemical sensing model based on nanomaterials for highly sensitive and specific determination of CTCs. A gold electrode co-modified with Ketjin black (KB) and Au nanoparticles (AuNPs) exhibits exceptional conductivity. By conjugating palladium-iridium cubic nanozyme (Pd-Ir CNE) with antibodies, we have created a detection probe capable of catalyzing hydrogen peroxide (H2O2), thereby amplifying the output signal and resulting in significantly enhanced current on the electrode for detecting CTCs. The constructed immunosensor has achieved a detection limit of 2 cell mL-1 for model MCF-7 cells. Furthermore, the as-constructed electrochemical immunosensor can accurately detect whole blood-spiked target CTCs, showing great promise for clinical applications in early cancer diagnosis and prognosis.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Células Neoplásicas Circulantes , Humanos , Ouro , Limite de Detecção , Técnicas Biossensoriais/métodos , Peróxido de Hidrogênio , Anticorpos Imobilizados , Imunoensaio/métodos , Técnicas Eletroquímicas/métodos
2.
Angew Chem Int Ed Engl ; 60(12): 6326-6332, 2021 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-33354840

RESUMO

Dual-ion batteries (DIBs) inherently suffer from limited energy density. Proposed here is a strategy to effectively tackle this issue by employing locally ordered graphitized carbon (LOGC) cathodes. Quantum mechanical modeling suggests that strong anion-anion repulsions and severe expansion at the deep-charging stage raise the anion intercalation voltage, therefore only part of the theoretical anion storage sites in graphite is accessible. The LOGC interconnected with disordered carbon is predicted to weaken the interlaminar van der Waals interactions, while disordered carbons not only interconnect the dispersed nanographite but also partially buffer severe anion-anion repulsion and offer extra capacitive anion storage sites. As a proof-of-concept, ketjen black (KB) with LOGC was used as a model cathode for a potassium-based DIB (KDIB). The KDIB delivers an unprecedentedly high specific capacity of 232 mAh g-1 at 50 mA g-1 , a good rate capability of 110 mAh g-1 at 2000 mA g-1 , and excellent cycling stability of 1000 cycles without obvious capacity fading.

3.
Mikrochim Acta ; 187(4): 216, 2020 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-32162013

RESUMO

An integrated electrochemical immunoassay is described for the determination of circulating tumor cells (CTCs). For the first time, Ketjen black (KB), which is a superconductive carbon material, was incorporated with Au nanoparticles (AuNPs) and used to modify the surface of gold electrodes. A cocktail of anti-epithelial cell adhesion molecules (EpCAM) and anti-vimentin antibodies was chosen to capture the CTCs. Palladium-iridium-boron-phosphorus alloy-modified mesoporous nanospheres (PdIrBPMNS) served as a catalytic tag to amplify the current signal. Glycine-HCl (Gly-HCl) was used as an antibody eluent to release and collect the captured CTCs from the electrodes for further clinical research without compromising cell viability. The response of the method increased linearly from 10 to 1 × 106 cells mL-1 CTCs, while the detection limit was calculated to be as low as 2 cells mL-1. This method was successfully used to determine CTCs in spiked blood samples and demonstrated good recovery. Graphical abstractKetjen black/AuNPs was incorporated in the electrochemical platform to enhance the electron transfer ability of the electrode surface. PdIrBP mesoporous nanospheres were used to amplify DPV signal in this assay. The introduction of Gly-HCl realized nondestructive recovery of circulating tumor cells.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Nanosferas/química , Células Neoplásicas Circulantes/patologia , Fuligem/química , Boro/química , Condutividade Elétrica , Humanos , Irídio/química , Paládio/química , Tamanho da Partícula , Fósforo/química , Porosidade , Propriedades de Superfície , Células Tumorais Cultivadas
4.
Chempluschem ; : e202400416, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-39404031

RESUMO

Lithium-sulfur (Li-S) batteries display promise as redox-based batteries, where separators are an essential part of preventing short-circuiting of the positive and negative electrodes, while the shuttle effect is a critical issue of separators. Currently, commercial PP separators are weak in inhibiting the polysulfides shuttling, so modified separators are needed to inhibit it to improve the battery performance. This paper reports that CeVO4/KB composites act as separator materials. CeVO4/KB modified PP separators enhanced the adsorption of LiPSs, accelerated the rate of Li+ migration, and catalyzed the conversion of LiPSs. These bring about the effect that CeVO4/KB/PP batteries reach 1200.9 mAh g-1 in the first cycle with a capacity retention rate of 86.5% after 100 cycles at 0.2 C and reach 882.7 mAh g-1 of the initial cycle with a capacity decay rate of 0.063% after 1000 cycles at 3 C. This work introduces rare earth metal vanadates to modify the separator, adding new ideas for designing separators for good-performance batteries.

5.
Biosens Bioelectron ; 262: 116541, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38959719

RESUMO

Human epididymis protein 4 (HE4), a diagnostic biomarker of ovarian cancer, is crucial for monitoring the early stage of the disease. Hence, it is highly important to develop simple, inexpensive, and user-friendly biosensors for sensitive and quantitative HE4 assays. Herein, a new sandwich-type electrochemical immunosensor based on Prussian blue (PB) as a signal indicator and functionalized metal-organic framework nanocompositesas efficient signal amplifiers was fabricated for quantitative analysis of HE4. In principle, ketjen black (KB) and AuNPs modified on TiMOF (TiMOF-KB@AuNPs) could accelerate electron transfer on the electrode surface and act as a matrix for the immobilization of antibodies via cross-linking to improve the determination sensitivity. The PB that covalently binds to labeled antibodies endows the biosensors with intense electrochemical signals. Furthermore, the concentration of HE4 could be indirectly detected by monitoring the electroactivity of PB. Benefiting from the high signal amplification ability of the PB and MOF nanocomposites, this strategy displayed a wide linear range (0.1-80 ng mL-1) and a lower detection limit (0.02 ng mL-1). Hence, this study demonstrated great promise for application in clinical ovarian cancer diagnosis and treatment, and provided a new platform for detecting other cancer biomarkers.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Ferrocianetos , Ouro , Limite de Detecção , Estruturas Metalorgânicas , Neoplasias Ovarianas , Proteína 2 do Domínio Central WAP de Quatro Dissulfetos , Técnicas Biossensoriais/métodos , Humanos , Estruturas Metalorgânicas/química , Proteína 2 do Domínio Central WAP de Quatro Dissulfetos/análise , Ferrocianetos/química , Técnicas Eletroquímicas/métodos , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/sangue , Feminino , Ouro/química , Nanopartículas Metálicas/química , Biomarcadores Tumorais/sangue , Biomarcadores Tumorais/análise , Imunoensaio/métodos , Anticorpos Imobilizados/química , Nanocompostos/química
6.
Talanta ; 253: 123955, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36179559

RESUMO

Circulating tumor cells (CTCs) are promising liquid biopsy biomarkers for early cancer detection and anti-cancer therapy evaluation. The ultra-low abundance of CTCs in blood samples requires highly sensitive and accurate detection ways. In this study, we propose the design of a dual-recognition electrochemical biosensor to improve both the specificity and signal response. PdPtCuRu mesoporous nanospheres (PdPtCuRu MNSs) with excellent three dimensions (3D) nanopore structures were synthesized by one-pot method and connected to mucin 1 (MUC1) aptamer to serve as signal amplification probe. Besides, superconductive carbon black, Ketjen Black (KB), and gold nanoparticles (AuNPs) modified organometallic frame (CeMOF-Au) were combined to work as signal transducer. The characteristic branching structure of KB provides abundant contact points to load CeMOF-Au to heighten the interface electron transfer rate. In addition, AuNPs were reduced on the surface of CeMOF, which could effectively bind the capture antibody and further enhance the conductivity. Under the optimized condition, the limit of detection (LOD) of the as-constructed biosensor was less than 10 cells mL-1 for model A549 cells, and showed good specificity and accuracy in spiked serum samples. We envision the as-proposed electrochemical biosensor would alternate as a useful tool for the clinical detection of CTCs for cancer diagnosis.


Assuntos
Ouro , Nanopartículas Metálicas
7.
Nanomaterials (Basel) ; 12(4)2022 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-35215020

RESUMO

In this paper, SiO2 aerogels were prepared by a sol-gel method. Using Ketjen Black (KB), Super P (SP) and Acetylene Black (AB) as a conductive agent, respectively, the effects of the structure and morphology of the three conductive agents on the electrochemical performance of SiO2 gel anode were systematically investigated and compared. The results show that KB provides far better cycling and rate performance than SP and AB for SiO2 anode electrodes, with a reversible specific capacity of 351.4 mA h g-1 at 0.2 A g-1 after 200 cycles and a stable 311.7 mA h g-1 at 1.0 A g-1 after 500 cycles. The enhanced mechanism of the lithium storage performance of SiO2-KB anode was also proposed.

8.
Nanomaterials (Basel) ; 12(9)2022 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-35564096

RESUMO

Silicon-based anodes are promising to replace graphite-based anodes for high-capacity lithium-ion batteries (LIB). However, the charge-discharge cycling suffers from internal stresses created by large volume changes of silicon, which form silicon-lithium compounds, and excessive consumption of lithium by irreversible formation of lithium-containing compounds. Consumption of lithium by the initial conditioning of the anode, as indicated by low initial coulombic efficiency (ICE), and subsequently continuous formation of solid-electrolyte-phase (SEI) on the freshly exposed silicon surface, are among the main issues. A high-performance, silicon-based, high-capacity anode exhibiting 88.8% ICE and the retention of 2 mAh/cm2 areal capacity after 200 discharge-charge cycles at the rate of 1 A/g is reported. The anode is made on a copper foil using a mixture of 70%:10%:20% by weight ratio of silicon flakes of 100 × 800 × 800 nm in size, Super P conductivity enhancement additive, and an equal-weight mixture of CMC and SBR binders. Pyrolysis of fabricated anodes at 700 °C in argon environment for 1 h was applied to convert the binders into a porous graphitic carbon structure that encapsulates individual silicon flakes. The porous anode has a mechanically strong and electrically conductive graphitic carbon structure formed by the pyrolyzed binders, which protect individual silicon flakes from excessive reactions with the electrolyte and help keep small pieces of broken silicon flakes together within the carbon structure. The selection and amount of conductivity enhancement additives are shown to be critical to the achievement of both high-ICE and high-capacity retention after long cycling. The Super P conductivity enhancement additive exhibits a smaller effective surface area where SEI forms compared to KB, and thus leads to the best combination of both high-ICE and high-capacity retention. A silicon-based anode exhibiting high capacity, high ICE, and a long cycling life has been achieved by the facile and promising one-step fabrication process.

9.
Front Neural Circuits ; 12: 108, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30532696

RESUMO

Recent advancements in electron microscope volume imaging, such as serial imaging using scanning electron microscopy (SEM), have facilitated the acquisition of three-dimensional ultrastructural information of biological samples. These advancements help build a comprehensive understanding of the functional structures in entire organelles, cells, organs and organisms, including large-scale wiring maps of neural circuitry in various species. Advanced volume imaging of biological specimens has often been limited by artifacts and insufficient contrast, which are partly caused by problems in staining, serial sectioning and electron beam irradiation. To address these issues, methods of sample preparation have been modified and improved in order to achieve better resolution and higher signal-to-noise ratios (SNRs) in large tissue volumes. These improvements include the development of new embedding media for electron microscope imaging that have desirable physical properties such as less deformation in the electron beam and higher stability for sectioning. The optimization of embedding media involves multiple resins and filler materials including biological tissues, metallic particles and conductive carbon black. These materials alter the physical properties of the embedding media, such as conductivity, which reduces specimen charge, ameliorates damage to sections, reduces image deformation and results in better ultrastructural data. These improvements and further studies to improve electron microscope volume imaging methods provide options for better scale, quality and throughput in the three-dimensional ultrastructural analyses of biological samples. These efforts will enable a deeper understanding of neuronal circuitry and the structural foundation of basic and higher brain functions.


Assuntos
Encéfalo/ultraestrutura , Microscopia Eletrônica de Varredura/métodos , Rede Nervosa/ultraestrutura , Inclusão do Tecido/normas , Animais , Encéfalo/citologia , Humanos , Rede Nervosa/citologia , Inclusão do Tecido/métodos
10.
ACS Appl Mater Interfaces ; 8(34): 22261-9, 2016 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-27502841

RESUMO

A highly conductive sulfur cathode is crucial for improving the kinetic performance of a Li-S battery. The encapsulation of sulfur in porous nanocarbons is expected to benefit the Li(+) migration, yet the e(-) conduction is still to be improved due to a low graphitization degree of a conventional carbon substrate, especially that pyrolyzed from carbohydrates or polymers. Aiming at facilitating the e(-) conduction in the cathode, here we propose to use ketjen black, a highly graphitized nanocarbon building block to form a conductive network for electrons in a biomass-derived, hierarchically porous carbon sponge by a easily scaled-up approach at a low cost. The specifically designed carbon host ensures a high loading and good retention of active sulfur, while also provides a faster electron transmission to benefit the lithiation/delithiation kinetics of sulfur. The sulfur cathode prepared from the carbon network shows excellent cycling and rate performance in a Li-S battery, rendering its practicality for emerging energy storage opportunities such as grids or automobiles.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa