1.
J Transl Med ; 20(1): 617, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-36564822

RESUMO

BACKGROUND: No direct approach assessing pulmonary vascular permeability exists in the current therapeutic strategy for patients with acute respiratory distress syndrome (ARDS). Transpulmonary thermodilution measures hemodynamic parameters such as pulmonary vascular permeability index and extravascular lung water, enabling clinicians to assess ARDS severity. The aim of this study is to explore a precise transpulmonary thermodilution-based criteria for quantifying the severity of lung injury using a clinically relevant septic-ARDS pig model. METHODS: Thirteen female pigs (weight: 31 ± 2 kg) were intubated, mechanically ventilated under anesthesia, and either assigned to septic shock-induced ARDS or control group. To confirm the development of ARDS, we performed computed tomography (CT) imaging in randomly selected animals. The pulmonary vascular permeability index, extravascular lung water, and other hemodynamic parameters were consecutively measured during the development of septic lung injury. Lung status was categorized as normal (partial pressure of oxygen/fraction of inspired oxygen ≥ 400), or injured at different degrees: pre-ARDS (300-400), mild-to-moderate ARDS (100-300), or severe ARDS (< 100). We also measured serum inflammatory cytokines and high mobility group box 1 levels during the experiment to explore the relationship of the pulmonary vascular permeability index with these inflammatory markers. RESULTS: Using CT image, we verified that animals subjected to ARDS presented an extent of consolidation in bilateral gravitationally dependent gradient that expands over time, with diffuse ground-glass opacification. Further, the post-mortem histopathological analysis for lung tissue identified the key features of diffuse alveolar damage in all animals subjected to ARDS. Both pulmonary vascular permeability index and extravascular lung water increased significantly, according to disease severity. Receiver operating characteristic analysis demonstrated that a cut-off value of 3.9 for the permeability index provided optimal sensitivity and specificity for predicting severe ARDS (area under the curve: 0.99, 95% confidence interval, 0.98-1.00; sensitivity = 100%, and specificity = 92.5%). The pulmonary vascular permeability index was superior in its diagnostic value than extravascular lung water. Furthermore, the pulmonary vascular permeability index was significantly associated with multiple parameters reflecting clinicopathological changes in animals with ARDS. CONCLUSION: The pulmonary vascular permeability index is an effective indicator to measure septic ARDS severity.


Assuntos
Lesão Pulmonar , Edema Pulmonar , Síndrome do Desconforto Respiratório , Choque Séptico , Infecção dos Ferimentos , Feminino , Suínos , Animais , Edema Pulmonar/complicações , Edema Pulmonar/diagnóstico , Termodiluição/métodos , Síndrome do Desconforto Respiratório/diagnóstico , Síndrome do Desconforto Respiratório/complicações , Pulmão/diagnóstico por imagem , Pulmão/irrigação sanguínea , Oxigênio
2.
Xenotransplantation ; 27(2): e12571, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31769101

RESUMO

BACKGROUND: Limited availability of decellularized allogeneic heart valve substitutes restricts the clinical application thereof. Decellularized xenogeneic valves might constitute an attractive alternative; however, increased immunological hurdles have to be overcome. This study aims for the in vivo effect in sheep of decellularized porcine pulmonary heart valves (dpPHV) enzymatically treated for N-glycan and DNA removal. METHODS: dpPHV generated by nine different decelluarization methods were characterized in respect of DNA, hydroxyproline, GAGs, and SDS content. Orthotopic implantation in sheep for six months of five groups of dpPHV (n = 3 each; 3 different decellularization protocols w/o PNGase F and DNase I treatment) allowed the analysis of function and immunological reaction in the ovine host. Allogenic doPHV implantations (n = 3) from a previous study served as control. RESULTS: Among the decellularization procedures, Triton X-100 & SDS as well as trypsin & Triton X-100 resulted in highly efficient removal of cellular components, while the extracellular matrix remained intact. In vivo, the functional performance of dpPHV was comparable to that of allogeneic controls. Removal of N-linked glycans and DNA by enzymatic PNGase F and DNase I treatment had positive effects on the clinical performance of Triton X-100 & SDS dpPHV, whereas this treatment of trypsin & Triton X-100 dpPHV induced the lowest degree of inflammation of all tested xenogeneic implants. CONCLUSION: Functional xenogeneic heart valve substitutes with a low immunologic load can be produced by decellularization combined with enzymatic removal of DNA and partial deglycosylation of dpPHV.


Assuntos
DNA/metabolismo , Próteses Valvulares Cardíacas/efeitos adversos , Valvas Cardíacas/metabolismo , Polissacarídeos/metabolismo , Engenharia Tecidual , Animais , Bioprótese/efeitos adversos , Ácido Desoxicólico/farmacologia , Detergentes/farmacologia , Matriz Extracelular/efeitos dos fármacos , Valvas Cardíacas/efeitos dos fármacos , Ovinos , Suínos , Engenharia Tecidual/métodos , Transplante Heterólogo/métodos
3.
Clin Oral Investig ; 20(1): 31-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25843053

RESUMO

OBJECTIVES: Bisphosphonate-related osteonecrosis of the jaw (BP-ONJ) occurs in 1 % of patients with medication-induced osteoporosis treated with bisphosphonates. Sheep are an established large animal model for investigating osteoporotic skeletal changes. Zoledronate significantly reduces tissue mineral variability in ovariectomized sheep. The aim of this study was to analyze bone healing after tooth extraction in sheep with induced osteopenia and zoledronate administration. MATERIALS AND METHODS: Eight adult ewes were randomly divided into two groups of four animals. All sheep underwent ovariectomy and a low-calcium diet. Dexamethasone was administered weekly for 16 weeks. Zoledronate was then given every third week for a further 16 weeks in four sheep; these infusions were repeated after extraction of two lower premolars. Four sheep without zoledronate administrations served as controls. RESULTS: Due to general health conditions, two sheep of the zoledronate group had to be excluded before surgery. The remaining two sheep of this group developed BP-ONJ lesions at the extraction site and various other sites in both jaws. Control group animals showed uneventful wound healing. Histology of the alveolar processes as well as lumbar spine revealed larger portions of old bone and smaller portions of new bone in the zoledronate group. CONCLUSIONS: This animal study showed uneventful wound healing after tooth extraction in osteopenic sheep whereas zoledronate treatment leads to development of BP-ONJ-like lesions. CLINICAL RELEVANCE: As bisphosphonate administration is a standard treatment for glucocorticoid-induced osteoporosis, this model can be used for further research in pathogenesis and management of bisphosphonate-related adverse events.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/patologia , Difosfonatos/toxicidade , Imidazóis/toxicidade , Cicatrização/fisiologia , Animais , Doenças Ósseas Metabólicas/induzido quimicamente , Dexametasona/toxicidade , Modelos Animais de Doenças , Feminino , Ovariectomia , Distribuição Aleatória , Carneiro Doméstico , Extração Dentária , Ácido Zoledrônico
4.
ACS Biomater Sci Eng ; 9(6): 2937-2948, 2023 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-36444758

RESUMO

Carbon monoxide (CO) is a therapeutic gas with therapeutic potential in intestinal bowel disease. Therapeutic efficacy in the gastrointestinal tract (GIT) must be paired with safe and convenient use. Therefore, we designed an oral CO releasing system (OCORS) pairing tunable CO release into the GIT while preventing the release of any other molecule from within the device, causing safety concerns. The dimensions of the device, which is manufactured from 3D printed components, are within compendial limits. This is achieved by controlling CO decarbonylation from a molybdenum complex with a FeCl3 solution. OCORS' surrounding silicon membranes control release rates, as does the loading with carbonylated molybdenum complex and FeCl3 solution. Herein we describe the development of the system, the characterization of the CO releasing molecule (CORM), and the CO release kinetics of the overall system. Neither the CORM nor isocyanoacetate as a potential reaction byproduct were cytotoxic. Finally, we demonstrated by design validation in an in vivo porcine model that, except for the release of the therapeutic CO, OCORS isolates all components during transit through the stomach. We could show that OCORS generated and released CO locally into the stomach of the animals without systemic exposure, measured as the carboxyhemoglobin content in the blood of the pigs. In conclusion, OCORS derisks oral development by limiting patient exposure to (desirable) CO while preventing contact with any further (undesirable) chemical, by-, or degradation products. CO generating devices come in reach, which now can be used by anyone, anywhere, and anytime.


Assuntos
Monóxido de Carbono , Molibdênio , Animais , Suínos , Monóxido de Carbono/uso terapêutico , Monóxido de Carbono/metabolismo
5.
Tissue Eng Part B Rev ; 29(5): 457-472, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36905366

RESUMO

Critical-sized bone defects (CSBDs) represent a significant clinical challenge, stimulating researchers to seek new methods for successful bone reconstruction. The aim of this systematic review is to assess whether bone marrow stem cells (BMSCs) combined with tissue-engineered scaffolds have demonstrated improved bone regeneration in the treatment of CSBD in large preclinical animal models. A search of electronic databases (PubMed, Embase, Web of Science, and Cochrane Library) focused on in vivo large animal studies identified 10 articles according to the following inclusion criteria: (1) in vivo large animal models with segmental bone defects; (2) treatment with tissue-engineered scaffolds combined with BMSCs; (3) the presence of a control group; and (4) a minimum of a histological analysis outcome. Animal research: reporting of in Vivo Experiments guidelines were used for quality assessment, and Systematic Review Center for Laboratory animal Experimentation's risk of bias tool was used to define internal validity. The results demonstrated that tissue-engineered scaffolds, either from autografts or allografts, when combined with BMSCs provide improved bone mineralization and bone formation, including a critical role in the remodeling phase of bone healing. BMSC-seeded scaffolds showed improved biomechanical properties and microarchitecture properties of the regenerated bone when compared with untreated and scaffold-alone groups. This review highlights the efficacy of tissue engineering strategies for the repair of extensive bone defects in preclinical large-animal models. In particular, the use of mesenchymal stem cells, combined with bioscaffolds, seems to be a successful method in comparison to cell-free scaffolds.

6.
JVS Vasc Sci ; 3: 182-191, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35495567

RESUMO

Objective: Many patients who require hemodialysis treatment will often require a prosthetic graft after multiple surgeries. However, the patency rate of grafts currently available commercially has not been satisfactory. Tissue engineering vascular grafts (TEVGs) are biodegradable scaffolds created to promote autologous cell proliferation and functional neotissue regeneration and, accordingly, have antithrombogenicity. Therefore, TEVGs can be an alternative prosthesis for small diameter grafts. However, owing to the limitations of the graft materials, most TEVGs are rigid and can easily kink when implanted in limited spaces, precluding future clinical application. Previously, we developed a novel corrugated nanofiber graft to prevent graft kinking. Reinforcement of these grafts to ensure their safety is required in a preclinical study. In the present study, three types of reinforcement were applied, and their effectiveness was examined using large animals. Methods: In the present study, three different reinforcements for the graft composed of corrugated poly-ε-caprolactone (PCL) blended with poly(L-lactide-co-ε-caprolactone) (PLCL) created with electrospinning were evaluated: 1) a polydioxanone suture, 2) a 2-0 polypropylene suture, 3) a polyethylene terephthalate/polyurethane (PET/PU) outer layer, and PCL/PLCL as the control. These different grafts were then implanted in a U-shape between the carotid artery and jugular vein in seven ovine models for a total of 14 grafts during a 3-month period. In evaluating the different reinforcements, the main factors considered were cell proliferation and a lack of graft dilation, which were evaluated using ultrasound examinations and histologic and mechanical analysis. Results: No kinking of the grafts occurred. Overall, re-endothelialization was observed in all the grafts at 3 months after surgery without graft rupture or calcification. The PCL/PLCL grafts and PCL/PLCL grafts with a polydioxanone suture showed high cell infiltration; however, they had become dilated 10 weeks after surgery. In contrast, the PCL/PLCL graft with the 2-0 suture and the PCL/PLCL graft covered with a PET/PU layer did not show any graft expansion. The PCL/PLCL graft covered with a PET/PU layer showed less cell infiltration than that of the PCL/PLCL graft. Conclusions: Reinforcement is required to create grafts that can withstand arterial pressure. Reinforcement with suture materials has the potential to maintain cell infiltration into the graft, which could improve the neotissue formation of the graft.

7.
JVS Vasc Sci ; 1: 100-108, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-34617042

RESUMO

OBJECTIVE: Prosthetic grafts are often needed in open vascular procedures. However, the smaller diameter prosthetic grafts (<6 mm) have low patency and often result in complications from infection. Tissue-engineered vascular grafts (TEVGs) are a promising replacement for small diameter prosthetic grafts. TEVGs start as a biodegradable scaffold to promote autologous cell proliferation and functional neotissue regeneration. Owing to the limitations of graft materials; however, most TEVGs are rigid and easily kinked when implanted in limited spaces, which precludes clinical application. We have developed a novel corrugated nanofiber graft to prevent kinking. METHODS: TEVGs with corrugated walls (5-mm internal diameter by 10 cm length) were created by electrospinning a blend of poly-ε-caprolactone and poly(L-lactide-co-caprolactone). The biodegradable grafts were then implanted between the carotid artery and the external jugular vein in a U-shape using an ovine model. TEVGs were implanted on both the left and right side of a sheep (n = 4, grafts = 8). The grafts were explanted 1 month after implantation and inspected with mechanical and histologic analyses. Graft patency was confirmed by measuring graft diameter and blood flow velocity using ultrasound, which was performed on day 4 and every following week after implantation. RESULTS: All sheep survived postoperatively except for one sheep that died of acute heart failure 2 weeks after implantation. The graft patency rate was 87.5% (seven grafts out of eight) with one graft becoming occluded in the early phase after implantation. There was no significant kinking of the grafts. Overall, endothelial cells were observed in the grafts 1 month after the surgeries without graft rupture, calcification, or aneurysmal change. CONCLUSIONS: Our novel corrugated nanofiber vascular graft displayed neotissue formation without kinking in large animal model.

8.
Cell Prolif ; 52(6): e12653, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31489992

RESUMO

OBJECTIVES: Bioreactor-based production systems have the potential to overcome limitations associated with conventional tissue engineering manufacturing methods, facilitating regulatory compliant and cost-effective production of engineered grafts for widespread clinical use. In this work, we established a bioreactor-based manufacturing system for the production of cartilage grafts. MATERIALS & METHODS: All bioprocesses, from cartilage biopsy digestion through the generation of engineered grafts, were performed in our bioreactor-based manufacturing system. All bioreactor technologies and cartilage tissue engineering bioprocesses were transferred to an independent GMP facility, where engineered grafts were manufactured for two large animal studies. RESULTS: The results of these studies demonstrate the safety and feasibility of the bioreactor-based manufacturing approach. Moreover, grafts produced in the manufacturing system were first shown to accelerate the repair of acute osteochondral defects, compared to cell-free scaffold implants. We then demonstrated that grafts produced in the system also facilitated faster repair in a more clinically relevant chronic defect model. Our data also suggested that bioreactor-manufactured grafts may result in a more robust repair in the longer term. CONCLUSION: By demonstrating the safety and efficacy of bioreactor-generated grafts in two large animal models, this work represents a pivotal step towards implementing the bioreactor-based manufacturing system for the production of human cartilage grafts for clinical applications. Read the Editorial for this article on doi:10.1111/cpr.12625.


Assuntos
Reatores Biológicos , Condrócitos/citologia , Engenharia Tecidual , Alicerces Teciduais , Doença Aguda , Animais , Cartilagem Articular/patologia , Doença Crônica , Feminino , Modelos Animais , Ovinos , Engenharia Tecidual/métodos
9.
J Tissue Eng Regen Med ; 12(3): 611-621, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28512850

RESUMO

Articular cartilage injuries experienced at an early age can lead to the development of osteoarthritis later in life. In situ three-dimensional (3D) printing is an exciting and innovative biofabrication technology that enables the surgeon to deliver tissue-engineering techniques at the time and location of need. We have created a hand-held 3D printing device (biopen) that allows the simultaneous coaxial extrusion of bioscaffold and cultured cells directly into the cartilage defect in vivo in a single-session surgery. This pilot study assessed the ability of the biopen to repair a full-thickness chondral defect and the early outcomes in cartilage regeneration, and compared these results with other treatments in a large animal model. A standardized critical-sized full-thickness chondral defect was created in the weight-bearing surface of the lateral and medial condyles of both femurs of six sheep. Each defect was treated with one of the following treatments: (i) hand-held in situ 3D printed bioscaffold using the biopen (HH group), (ii) preconstructed bench-based printed bioscaffolds (BB group), (iii) microfractures (MF group) or (iv) untreated (control, C group). At 8 weeks after surgery, macroscopic, microscopic and biomechanical tests were performed. Surgical 3D bioprinting was performed in all animals without any intra- or postoperative complication. The HH biopen allowed early cartilage regeneration. The results of this study show that real-time, in vivo bioprinting with cells and scaffold is a feasible means of delivering a regenerative medicine strategy in a large animal model to regenerate articular cartilage.


Assuntos
Bioimpressão , Cartilagem Articular/fisiologia , Impressão Tridimensional , Regeneração/fisiologia , Animais , Fenômenos Biomecânicos , Cartilagem Articular/cirurgia , Masculino , Células-Tronco Mesenquimais/citologia , Ovinos , Engenharia Tecidual
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa