Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
MAGMA ; 29(4): 699-709, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26762244

RESUMO

OBJECTIVES: The recently reported inhomogeneous magnetization transfer technique (ihMT) has been proposed for specific imaging of inhomogeneously broadened lines, and has shown great promise for characterizing myelinated tissues. The ihMT contrast is obtained by subtracting magnetization transfer images obtained with simultaneous saturation at positive and negative frequency offsets (dual frequency saturation experiment, MT (+/-)) from those obtained with single frequency saturation (MT (+)) at the same total power. Hence, ihMT may be biased by MT-asymmetry, especially at ultra-high magnetic field. Use of the average of single positive and negative frequency offset saturation MT images, i.e., (MT (+)+MT (-)) has been proposed to correct the ihMT signal from MT-asymmetry signal. MATERIALS AND METHODS: The efficiency of this correction method was experimentally assessed in this study, performed at 11.75 T on mice. Quantitative corrected ihMT and MT-asymmetry ratios (ihMTR and MTRasym) were measured in mouse brain structures for several MT-asymmetry magnitudes and different saturation parameter sets. RESULTS: Our results indicated a "safe" range of magnitudes (/MTRasym/<4 %) for which MT-asymmetry signal did not bias the corrected ihMT signal. Moreover, experimental evidence of the different natures of both MT-asymmetry and inhomogeneous MT contrasts were provided. In particular, non-zero ihMT ratios were obtained at zero MTRasym values. CONCLUSION: MTRasym is not a confounding factor for ihMT quantification, even at ultra-high field, as long as MTRasym is restricted to ±4 %.


Assuntos
Campos Magnéticos , Imageamento por Ressonância Magnética , Magnetismo , Bainha de Mielina/química , Algoritmos , Animais , Encéfalo/diagnóstico por imagem , Feminino , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Camundongos , Camundongos Endogâmicos C57BL
2.
Radiol Phys Technol ; 17(1): 93-102, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37897684

RESUMO

The aim of this study is to develop a novel phantom for the evaluation of clinical CEST imaging settings, e.g., B0 and B1 field inhomogeneities, CEST contrast, and post-processing. We made a phantom composed of two slice sections: a grid section for local offset frequency evaluation and a sample section for CEST effect evaluation using different concentrations of an egg white albumin solution. On a 3 Tesla MR scanner, a phantom study was performed using CEST imaging; the mean B1 amplitudes were set at 1.2 and 1.9 µT, and CEST images with and without B0 corrections were acquired. Next, region of interest (ROI) analysis was performed for each slice. Then, CEST images with and without B0 corrections were compared at each B1 amplitude. The B0 corrected Z-spectrums at each local region in the grid section showed a shifting of the curve bottom to 0 ppm. Z-spectrum at B1 = 1.9 µT showed a broader curve shape than that at 1.2 µT. Moreover, MTRasym values at 3.5 ppm for each albumin sample at B1 = 1.9 µT were about two times higher than those at 1.2 µT. Our phantom enabled us to evaluate and optimize B0 inhomogeneity and the CEST effect at the B1 amplitude.


Assuntos
Albuminas , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
3.
Magn Reson Med ; 70(2): 320-7, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23661598

RESUMO

PURPOSE: To investigate the saturation-power dependence of amide proton transfer (APT)-weighted and nuclear Overhauser enhancement-weighted image contrasts in a rat glioma model at 4.7 T. METHODS: The 9L tumor-bearing rats (n = 8) and fresh chicken eggs (n = 4) were scanned on a 4.7-T animal magnetic resonance imaging scanner. Z-spectra over an offset range of ±6 ppm were acquired with different saturation powers, followed by the magnetization transfer-ratio asymmetry analyses around the water resonance. RESULTS: The nuclear Overhauser enhancement signal upfield from the water resonance (-2.5 to -5 ppm) was clearly visible at lower saturation powers (e.g., 0.6 µT) and was larger in the contralateral normal brain tissue than in the tumor. Conversely, the APT effect downfield from the water resonance was maximized at relatively higher saturation powers (e.g., 2.1 µT) and was larger in the tumor than in the contralateral normal brain tissue. The nuclear Overhauser enhancement decreased the APT-weighted image signal, based on the magnetization transfer-ratio asymmetry analysis, but increased the APT-weighted image contrast between the tumor and contralateral normal brain tissue. CONCLUSION: The APT and nuclear Overhauser enhancement image signals in tumor are maximized at different saturation powers. The saturation power of roughly 2 µT is ideal for APT-weighted imaging at clinical B0 field strengths.


Assuntos
Algoritmos , Neoplasias Encefálicas/patologia , Glioma/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Animais , Linhagem Celular Tumoral , Embrião de Galinha , Ratos , Ratos Endogâmicos F344 , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa