Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
BMC Gastroenterol ; 24(1): 20, 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38182996

RESUMO

BACKGROUND: To investigate the feasibility of a deformable self-assembled magnetic anastomosis ring (DSAMAR), designed and developed by us, for endoscopic gastrointestinal bypass anastomosis. METHODS: Ten experimental pigs were used as model animals. The DSAMAR comprises 10 trapezoidal magnetic units, arranged in a straight line under the constraint of a guide wire. When the desired anastomosis site is reached under the guidance of an endoscope, the catheter pushes the magnetic unit along the guide wire. The linear DSAMAR can be assembled into a circular DSAMAR. Two DSAMARs were inserted, one at the end of the duodenum and the other into the stomach successively. They attracted each other and compressed the wall of the stomach and duodenum to establish gastrointestinal bypass anastomosis. The experimental pigs were euthanized 4 weeks after the operation, and the gastrointestinal bypass anastomosis specimens were obtained. The anastomosis formation was evaluated by the naked eye and histology. RESULTS: Gastrointestinal bypass anastomosis with DSAMARs was successfully performed. The average operation time under an endoscope was 70.30 ± 19.05 min (range: 43-95 min). The DSAMARs were discharged through the anus 10-17 days after surgery. There were no complications such as gastrointestinal bleeding, perforation, anastomotic fistula, and gastrointestinal obstruction during and after the operation. Gastroscopy and gross specimen of the anastomosis showed a well-formed magnetic anastomosis. Histological observation showed good continuity of the serous membrane and the mucosa of magnetic anastomosis. CONCLUSION: The DSAMAR is a safe and feasible device for fashioning gastrointestinal bypass anastomosis in this animal model.


Assuntos
Gastroscopia , Estômago , Suínos , Animais , Anastomose Cirúrgica , Estômago/cirurgia , Duodeno , Fenômenos Magnéticos
2.
Surg Endosc ; 37(2): 1005-1012, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36085384

RESUMO

BACKGROUND: There have been no prospective randomized controlled clinical trials evaluating the advantages of the magnetic anchor technique (MAT) used in reduced-port laparoscopic cholecystectomy (LC). The present study evaluated a novel magnetic anchor device designed by the authors. METHODS: Between April 2019 and June 2020, 60 patients with gallbladder diseases participated in a single-center, prospective, randomized controlled clinical trial. The patients were randomly apportioned to undergo either 2-port LC assisted by the novel MAT (MAT-2P-LC, experimental group) or conventional 3-port LC (3P-LC, control). The groups were compared regarding operative time, postoperative complications, surgical incision pain score (Wong-Baker), and other indicators. The patients were followed for 2 years. RESULTS: The test and control groups were comparable in age, gender, body mass index, and primary disease. No patient in the MAT-2P-LC group was converted to 3P-LC. No patients were converted to laparotomy. On the first postoperative day, the Wong-Baker pain score of the experimental group (1.60 ± 0.67) was significantly lower than that of the control (2.20 ± 0.76; P = 0.002). The groups were statistically similar regarding intraoperative blood loss; operative time; time to leave bed; hospital stay; postoperative pain scores at 1 and 4 weeks; and complications. CONCLUSIONS: This rigorous clinical trial shows that the novel MAT used to assist reduced-port LC significantly reduced postoperative pain, but has no obvious advantages in other terms. Clinical Trails.gov. number, ChiCTR1800019464.


Assuntos
Colecistectomia Laparoscópica , Doenças da Vesícula Biliar , Humanos , Colecistectomia Laparoscópica/métodos , Doenças da Vesícula Biliar/cirurgia , Dor Pós-Operatória/cirurgia , Complicações Pós-Operatórias/cirurgia , Duração da Cirurgia , Tempo de Internação , Fenômenos Magnéticos
3.
J Surg Res ; 276: 283-290, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35405414

RESUMO

INTRODUCTION: The magnetic compression technique (MCT) is used for the anastomosis of hollow organs by the means of suction between magnets. The MCT is useful for establishing digestive tract anastomoses in rats, for example, end-to-side small intestinal anastomosis and colonic anastomosis. We aim to determine the feasibility of MCT-based esophageal anastomosis in rats. METHODS: Twenty-four Sprague-Dawley albino rats (230-250 g) were randomly divided into an MCT group and a control group (hand-sewn esophageal anastomosis). The time required to construct the anastomosis, postoperative complications, and survival rate was compared between the two groups. At 2 wk postoperatively, the animals were sacrificed to assess the burst pressure and histological features of the anastomoses. RESULTS: The mean anastomosis time was significantly lower for MCT (11.17 ± 1.64 min) than for the hand-sewn technique (27.42 ± 2.23 min; P < 0.001). The survival rate was slightly higher in the MCT group (91.67%) than in the control group (66.67%, P = 0.317). The magnets were discharged from the body after 8.33 ± 0.89 d (range, 7-10 d). No anastomotic leakage or stenosis occurred in the MCT group. Three rats developed anastomotic stenosis and two rats developed anastomotic leakage in the control group. The burst pressures were similar in the two groups. An histological examination showed that compared with the control group, the MCT group had better alignment of the tissue layers and less inflammation. CONCLUSIONS: The MCT is a simple and feasible technique for esophageal anastomosis in rats and has the potential for clinical application.


Assuntos
Anastomose Cirúrgica , Procedimentos Cirúrgicos do Sistema Digestório , Esôfago , Imãs , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Fístula Anastomótica/etiologia , Fístula Anastomótica/prevenção & controle , Animais , Constrição Patológica/etiologia , Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Procedimentos Cirúrgicos do Sistema Digestório/instrumentação , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Esôfago/cirurgia , Fenômenos Magnéticos , Ratos , Ratos Sprague-Dawley , Técnicas de Sutura
4.
Surg Endosc ; 36(11): 8170-8177, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35501603

RESUMO

BACKGROUND: Being one of the core techniques of magnetic surgery, magnetic compression technique (MCT) has been used for digestive tract anastomosis reconstruction in experimental studies. This study verified the feasibility of gastroenteric anastomosis through natural orifice using MCT in rats. METHODS: The parent and daughter magnets were designed and manufactured for oral and anal insertion in 20 Sprague-Dawley rats. After anesthesia, the parent magnet was inserted into the colon spleen area through the anus, and the daughter magnet was inserted into the stomach through the mouth. Then the two magnets were positioned to attract each other and bind together. The position of the two magnets was monitored using X-ray. The time required for the formation of the anastomosis and expulsion of the magnets were recorded. 2 weeks later, the animal was sacrificed and the anastomotic specimen was obtained which was observed under naked eye and microscope. RESULTS: The gastroenteric anastomosis was successfully performed via natural orifices in 18 out of 20 rats. The mean time to construct the anastomosis was 3.78 ± 0.88 min. X-ray examination showed that the magnets were in the appropriate position in 17 rats. The magnets were excreted in 9.47 ± 1.62 days after surgery. The gross and microscopic examination of the specimen showed that the anastomoses were patent and the mucosa at the anastomotic was smooth. The mean bursting pressure of the anastomosis was 136.94 ± 6.79 mmHg. CONCLUSION: It is feasible to perform gastroenteric anastomosis through natural orifices by MCT.


Assuntos
Magnetismo , Imãs , Ratos , Animais , Ratos Sprague-Dawley , Anastomose Cirúrgica/métodos , Fenômenos Magnéticos
5.
Hepatobiliary Pancreat Dis Int ; 21(4): 340-346, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35022144

RESUMO

BACKGROUND: Although laparoscopic technology has achieved rapid development in the surgical field, it has not been applied to liver transplantation, primarily because of difficulties associated with laparoscopic vascular anastomosis. In this study, we introduced a new magnetic-assisted vascular anastomosis technique and explored its application in laparoscopic liver transplantation in pigs. METHODS: Two sets of magnetic vascular anastomosis rings (MVARs) with different diameters were developed. One set was used for anastomosis of the suprahepatic vena cava (SHVC) and the other set was used for anastomosis of the infrahepatic vena cava (IHVC) and portal vein (PV). Six laparoscopic orthotopic liver transplantations were performed in pigs. Donor liver was obtained via open surgery. Hepatectomy was performed in the recipients through laparoscopic surgery. Anastomosis of the SHVC was performed using hand-assisted magnetic anastomosis, and the anastomosis of the IHVC and PV was performed by magnetic anastomosis with or without hand assistance. RESULTS: Liver transplants were successfully performed in five of the six cases. Postoperative ultrasonographic examination showed that the portal inflow was smooth. However, PV bending and blood flow obstruction occurred in one case because the MVARs were attached to each other. The durations of loading of MVAR in the laparoscope group and manual assistance group for IHVC and PV were 13 ± 5 vs. 5 ± 1 min (P < 0.01) and 10 ± 2 vs. 4 ± 1 min (P < 0.05), respectively. The durations of MVAR anastomosis in the laparoscope group and manual assistance group for IHVC and PV were 5 ± 1 vs. 1 ± 1 min (P < 0.01), and 5 ± 1 vs. 1 ± 1 min (P < 0.01), respectively. The anhepatic phase was 43 ± 4 min in the laparoscope group and 23 ± 2 min in the manual assistance group (P < 0.01). CONCLUSIONS: Our study showed that magnetic-assisted laparoscopic liver transplantation can be successfully carried out in pigs.


Assuntos
Laparoscopia , Transplante de Fígado , Anastomose Cirúrgica/métodos , Animais , Humanos , Transplante de Fígado/métodos , Doadores Vivos , Fenômenos Magnéticos , Veia Porta/diagnóstico por imagem , Veia Porta/cirurgia , Suínos , Veia Cava Inferior/cirurgia
6.
Zhongguo Yi Liao Qi Xie Za Zhi ; 45(6): 612-615, 2021 Nov 30.
Artigo em Chinês | MEDLINE | ID: mdl-34862772

RESUMO

Based on the principle of magnetic anastomosis technique, the design of magnetic anastomosis system for endoscopic tissue clamping is proposed. The system includes a semi-ring magnet, a special structure transparent cap and a detachable push rod. With the help of the existing digestive endoscopy and endoscopic tissue gripper, the endoscopic close clamping and anastomosis of the bleeding or perforated tissue can be completed. After the anastomosis, the magnet falls off and is discharged through the digestive tract. Animal experiments showed that the system was easy to use, the fistula was clamped firmly, the magnet was discharged for 7~21 days, and there was no magnet retention and digestive tract obstruction. Further safety verification, optimization of endoscopic operation, the system can be used in clinical trial.


Assuntos
Magnetismo , Imãs , Anastomose Cirúrgica , Animais , Constrição , Endoscopia Gastrointestinal
7.
Zhongguo Yi Liao Qi Xie Za Zhi ; 43(5): 334-336, 2019 Sep 30.
Artigo em Chinês | MEDLINE | ID: mdl-31625329

RESUMO

Laparoscopic surgery based on magnetic anchor technique has great potential for further minimally invasive surgery and good surgical field exposure, in which the internal grasper is the key factor. In this paper, an internal grasper based on magnetic anchor laparoscopic surgery is designed, which consists of three parts:target magnet, connection module and tissue forceps. The magnetic shield shell is used to wrap the magnetic core in the target magnet, which not only can increase the magnetic force in the working area, but also reduce the magnetic interference between the instruments, and the connecting module can flexibly adjust the length of the internal grasper. The special structure of tissue gripper can effectively reduce deputy injury and facilitate the replacement of clamp position. It has many advantages, such as ingenious design, easy processing, simple operation and wide range of application, which greatly increased its clinical application value.


Assuntos
Laparoscopia , Instrumentos Cirúrgicos , Desenho de Equipamento , Magnetismo , Imãs
8.
Surg Endosc ; 32(2): 895-899, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28733750

RESUMO

INTRODUCTION: Magnet-assisted surgery is a new platform within minimally invasive surgery. The Levita™ Magnetic Surgical System, the first magnetic surgical system to receive Food and Drug Administration (FDA) approval, includes a deployable, magnetic grasper and an external magnet that is used to manipulate the grasper within the peritoneal cavity. This system is currently approved for patients undergoing laparoscopic cholecystectomy with a body mass index (BMI) between 21 and 34 kg/m2. Herein, we detail the first United States experience with the Levita™ Magnetic Surgical System during laparoscopic cholecystectomy. METHODS: The Levita™ Magnetic Surgical System was used on consecutive patients undergoing laparoscopic cholecystectomy at our institution from June 2016 through November 2016. Only patients undergoing elective surgery and those with a body mass index (BMI) between 21 and 34 kg/m2 were included. Baseline patient characteristics, operative time, and perioperative details were collected. RESULTS: A total of ten patients underwent laparoscopic cholecystectomy with the Levita™ Magnetic Surgical System during the defined study period. The mean age at the time of surgery was 49.0 years and the average BMI of the cohort was 27.6 kg/m2. The average operative time was 64.4 min. There were no perioperative complications. Seven (70.0%) patients were discharged to home on the day of surgery, while the remaining three (30.0%) patients were discharged to home on postoperative day number one. Surgeons reported that the magnetic grasper was easy to use and provided adequate tissue retraction and exposure. CONCLUSIONS: The Levita™ Magnetic Surgical System is safe and feasible to use in patients undergoing laparoscopic cholecystectomy. Routine use of this system may facilitate a reduction in the total number of laparoscopic trocars used, leading to less tissue trauma and improved cosmesis. Additional studies are needed to determine the applicability and utility of this system for other general surgery cases.


Assuntos
Colecistectomia Laparoscópica/instrumentação , Imãs , Adulto , Colecistectomia Laparoscópica/métodos , Procedimentos Cirúrgicos Eletivos/instrumentação , Procedimentos Cirúrgicos Eletivos/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Avaliação de Resultados em Cuidados de Saúde , Seleção de Pacientes , Estudos Retrospectivos , Estados Unidos , Adulto Jovem
9.
World J Gastrointest Surg ; 16(5): 1443-1448, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38817285

RESUMO

BACKGROUND: The treatment of postoperative anastomotic stenosis (AS) after resection of colorectal cancer is challenging. Endoscopic balloon dilation is used to treat stenosis in such cases, but some patients do not show improvement even after multiple balloon dilations. Magnetic compression technique (MCT) has been used for gastrointestinal anastomosis, but its use for the treatment of postoperative AS after colorectal cancer surgery has rarely been reported. CASE SUMMARY: We report a 72-year-old man who underwent radical resection of colorectal cancer and ileostomy one year ago. An ileostomy closure was prepared six months ago, but colonoscopy revealed a narrowing of the rectal anastomosis. Endoscopic balloon dilation was performed three times, but colonoscopy showed no significant improvement in stenosis. The AS was successfully treated using MCT. CONCLUSION: MCT is a minimally invasive method that can be used for the treatment of postoperative AS after colorectal cancer surgery.

10.
Sci Rep ; 14(1): 10602, 2024 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719935

RESUMO

Although the application of magnetic compression anastomosis is becoming increasingly widespread, the magnets used in earlier studies were mostly in the shape of a whole ring. Hence, a deformable self-assembled magnetic anastomosis ring (DSAMAR) was designed in this study for gastrointestinal anastomosis. Furthermore, its feasibility was studied using a beagle model. The designed DSAMAR comprised 10 trapezoidal magnetic units. Twelve beagles were used as animal models, and DSAMARs were inserted into the stomach and colon through the mouth and anus, respectively, via endoscopy to achieve gastrocolic magnamosis. Surgical time, number of failed deformations, survival rate of the animals, and the time of magnet discharge were documented. A month later, specimens of the anastomosis were obtained and observed with the naked eye as well as microscopically. In the gastrocolic anastomosis of the 12 beagles, the procedure took 65-120 min. Although a deformation failure occurred during the operation in one of the beagles, it was successful after repositioning. The anastomosis was formed after the magnet fell off 12-18 days after the operation. Naked eye and microscopic observations revealed that the anastomotic specimens obtained 1 month later were well-formed, smooth, and flat. DSAMAR is thus feasible for gastrointestinal anastomosis under full endoscopy via the natural orifice.


Assuntos
Anastomose Cirúrgica , Estudos de Viabilidade , Animais , Cães , Anastomose Cirúrgica/métodos , Estômago/cirurgia , Imãs , Magnetismo , Cirurgia Endoscópica por Orifício Natural/métodos , Cirurgia Endoscópica por Orifício Natural/instrumentação , Colo/cirurgia , Masculino
11.
World J Gastrointest Surg ; 16(6): 1933-1938, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38983322

RESUMO

BACKGROUND: The combination of magnetic compression anastomosis (MCA) and endoscopy has been used to treat biliary stricture after liver transplantation. However, its use for the treatment of complex biliary obstruction after major abdominal trauma has not been reported. This case report describes the successful use of MCA for the treatment of biliary obstruction resulting from major abdominal trauma. CASE SUMMARY: A 23-year-old man underwent major abdominal surgery (repair of liver rupture, right half colon resection, and ileostomy) following a car accident one year ago. The abdominal drainage tube, positioned at the Winslow foramen, was draining approximately 600-800 mL of bile per day. During the two endoscopic retrograde cholangiopancreatography procedures, the guide wire was unable to enter the common bile duct, which prevented placement of a biliary stent. MCA combined with endoscopy was used to successfully achieve magnetic anastomosis of the peritoneal sinus tract and duodenum, and then a choledochoduodenal stent was placed. Finally, the external biliary drainage tube was removed. The patient achieved internal biliary drainage leading to the removal of the external biliary drainage tube, which improved the quality of life. CONCLUSION: Magnetic compression technique can be used for the treatment of complex biliary obstruction with minimal operative trauma.

12.
World J Gastroenterol ; 30(16): 2272-2280, 2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38690021

RESUMO

BACKGROUND: The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula (TEF), but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control. We designed a T-shaped magnet system to overcome these problems and verified its effectiveness via animal experiments. AIM: To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs. METHODS: Twelve beagles were randomly assigned to groups in which magnets of the T-shaped scheme (study group, n = 6) or normal magnets (control group, n = 6) were implanted into the trachea and esophagus separately under gastroscopy. Operation time, operation success rate, and accidental injury were recorded. After operation, the presence and timing of cough and the time of magnet shedding were observed. Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing, and gross specimens of TEFs were obtained. Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery, and gross specimens were obtained. Fistula size was measured in all animals, and then harvested fistula specimens were examined by hematoxylin and eosin (HE) and Masson trichrome staining. RESULTS: The operation success rate was 100% for both groups. Operation time did not differ between the study group (5.25 min ± 1.29 min) and the control group (4.75 min ± 1.70 min; P = 0.331). No bleeding, perforation, or unplanned magnet attraction occurred in any animal during the operation. In the early postoperative period, all dogs ate freely and were generally in good condition. Dogs in the control group had severe cough after drinking water at 6-9 d after surgery. X-ray indicated that the magnets had entered the stomach, and gastroscopy showed TEF formation. Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm ± 1.29 mm (range, 3.52-6.56 mm). HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas. Dogs in the study group did not exhibit obvious coughing after surgery. X-ray examination 2 wk after surgery indicated fixed magnet positioning, and gastroscopy showed no change in magnet positioning. The magnets were removed using a snare under endoscopy, and TEF was observed. Gross specimens showed well-formed fistulas with a diameter of 6.11 mm ± 0.16 mm (range, 5.92-6.36 mm), which exceeded that in the control group (P < 0.001). Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining, and the structure was more regular than that in the control group. CONCLUSION: Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets. Most importantly, this model offers better controllability, which improves the flexibility of follow-up studies.


Assuntos
Modelos Animais de Doenças , Imãs , Traqueia , Fístula Traqueoesofágica , Animais , Cães , Fístula Traqueoesofágica/cirurgia , Fístula Traqueoesofágica/patologia , Fístula Traqueoesofágica/etiologia , Traqueia/cirurgia , Traqueia/patologia , Esôfago/cirurgia , Esôfago/patologia , Esôfago/diagnóstico por imagem , Gastroscopia/instrumentação , Gastroscopia/métodos , Duração da Cirurgia , Masculino , Magnetismo/instrumentação , Desenho de Equipamento , Humanos
13.
World J Gastroenterol ; 30(6): 599-606, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38463020

RESUMO

BACKGROUND: Treatment of postoperative anastomotic stenosis for colorectal cancer is often challenging, especially for patients who do not respond well to endoscopy. In cases where patients have undergone an enterostomy, the stenosis can be easily resolved through magnetic compression. However, common magnetic compression techniques cannot be performed on those without enterostomy. We designed a novel Y-Z deformable magnetic ring (Y-Z DMR) and successfully applied it to a patient with a stenosis rectal anastomosis and without enterostomy after rectal cancer surgery. CASE SUMMARY: We here report the case of a 57-year-old woman who had undergone a laparoscopic radical rectum resection (Dixon) for rectal cancer. However, she started facing difficulty in defecation 6 months after surgery. Her colonoscopy indicated stenosis of the rectal anastomosis. Endoscopic balloon dilation was performed six times on her. However, the stenosis still showed a trend of gradual aggravation. Because the patient did not undergo an enterostomy, the conventional endoscopic magnetic compression technique could not be performed. Hence, we implemented a Y-Z DMR implemented through the anus under single channel. The magnetic ring fell off nine days after the operation and the rectal stenosis was relieved. The patient was followed up for six months and reported good defecation. CONCLUSION: The Y-Z DMR deformable magnetic ring is an excellent treatment strategy for patients with rectal stenosis and without enterostomy.


Assuntos
Laparoscopia , Neoplasias Retais , Humanos , Feminino , Pessoa de Meia-Idade , Constrição Patológica/cirurgia , Constrição Patológica/etiologia , Neoplasias Retais/complicações , Neoplasias Retais/cirurgia , Reto/diagnóstico por imagem , Reto/cirurgia , Laparoscopia/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Complicações Pós-Operatórias/etiologia , Fenômenos Magnéticos , Estudos Retrospectivos
14.
World J Gastrointest Surg ; 16(6): 1926-1932, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38983326

RESUMO

BACKGROUND: The treatment of postoperative anastomotic stenosis after excision of rectal cancer is challenging. Endoscopic balloon dilation and radial incision are not effective in all patients. We present a new endoscopy-assisted magnetic compression technique (MCT) for the treatment of rectal anastomotic stenosis. We successfully applied this MCT to a patient who developed an anastomotic stricture after radical resection of rectal cancer. CASE SUMMARY: A 50-year-old man had undergone laparoscopic radical rectal cancer surgery at a local hospital 5 months ago. A colonoscopy performed 2 months ago indicated that the rectal anastomosis was narrow due to which ileostomy closure could not be performed. The patient came to the Magnetic Surgery Clinic of the First Affiliated Hospital of Xi'an Jiaotong University after learning that we had successfully treated patients with colorectal stenosis using MCT. We performed endoscopy-assisted magnetic compression surgery for rectal stenosis. The magnets were removed 16 d later. A follow-up colonoscopy performed after 4 months showed good anastomotic patency, following which, ileostomy closure surgery was performed. CONCLUSION: MCT is a simple, non-invasive technique for the treatment of anastomotic stricture after radical resection of rectal cancer. The technique can be widely used in clinical settings.

15.
World J Gastrointest Surg ; 16(5): 1336-1343, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38817276

RESUMO

BACKGROUND: Magnetic anchor technique (MAT) has been applied in laparoscopic cholecystectomy and laparoscopic appendectomy, but has not been reported in laparoscopic partial hepatectomy. AIM: To evaluate the feasibility of the MAT in laparoscopic left lateral segment liver resection. METHODS: Retrospective analysis was conducted on the clinical data of eight patients who underwent laparoscopic left lateral segment liver resection assisted by MAT in our department from July 2020 to November 2021. The Y-Z magnetic anchor devices (Y-Z MADs) was independently designed and developed by the author of this paper, which consists of the anchor magnet and magnetic grasping apparatus. Surgical time, intraoperative blood loss, intraoperative accidents, operator experience, postoperative incision pain score, postoperative complications, and other indicators were evaluated and analyzed. RESULTS: All eight patients underwent a MAT-assisted laparoscopic left lateral segment liver resection, including three patients undertaking conventional 5-port and five patients having a transumbilical single-port operation. The mean operation time was 138 ± 34.32 min (range 95-185 min) and the mean intraoperative blood loss was 123 ± 88.60 mL (range 20-300 mL). No adverse events occurred during the operation. The Y-Z MADs showed good workability and maneuverability in both tissue and organ exposure. In particular, the operators did not experience either a "chopstick" or "sword-fight" effect in the single-port laparoscopic operation. CONCLUSION: The results show that the MAT is safe and feasible for laparoscopic left lateral segment liver resection, especially, exhibits its unique abettance for transumbilical single-port laparoscopic left lateral segment liver resection.

16.
Technol Health Care ; 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39302395

RESUMO

BACKGROUND: Endoscopic submucosal dissection (ESD) is a well-established treatment for gastrointestinal tumors and enables en bloc resection. Adequate counter traction with good visualization is important for safe and effective dissection. OBJECTIVE: Based on magnetic anchor-guided endoscopic submucosal dissection (MAG-ESD), we would like to explore the feasibility of magnetic hydrogel as an internal magnetic anchor that can be injected into the submucosa through an endoscopic needle to assist colonic endoscopic submucosal dissection. METHODS: This prospective trial was conducted on 20 porcine colons ex vivo. We injected magnetic hydrogel into submucosa of the porcine colons ex vivo for MAG-ESD to evaluate the traction effect and operation satisfaction. RESULTS: Magnetic hydrogel assisted ESD was successfully performed on 20 porcine colons ex vivo. Adequate counter traction with good visualization was successfully obtained during the procedure of dissection. CONCLUSION: Magnetic hydrogel assisted MAG-ESD is feasible and effective.

17.
Obes Surg ; 33(7): 2261-2265, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37209389

RESUMO

BACKGROUND: Sleeve gastrectomy is one of the most popular bariatric surgeries. With the advent of new technologies, a reduced-port approach assisted by magnets for sleeve gastrectomy (RPSG-MA) has been developed. The aim of our study is to compare the short-term results of RPSG-MA vs conventional laparoscopic SG (CLSG). METHODS: A comparative study was performed. We compared two groups who underwent RPSG-MA (n=150) and CLSG (n=135) between January 2020 and January 2022. RESULTS: Both groups were similar in body mass index, age, sex, and type of comorbidities. The operative time was similar in both groups (RPSG-MA, 52.5 min vs CLSG, 52.9 min; p = 0.829). Length of hospital (1.07 days) stay was significantly shorter in the RPSG-MA group (p = 0.00) than in the CLSG group (1.51 days). There were no conversions to open surgery in any patient or any fatal event. Complications encountered were similar in both groups postoperative. There were minor adverse events directly related to the magnetic device in 3 cases, these being mild hepatic lacerations, resolved with hemostatic measures. CONCLUSION: The magnet-assisted reduced-port gastric sleeve compared to the conventional technique has proven to be safe, technically feasible and with multiple benefits.


Assuntos
Cirurgia Bariátrica , Laparoscopia , Obesidade Mórbida , Humanos , Obesidade Mórbida/cirurgia , Laparoscopia/métodos , Gastrectomia/métodos , Cirurgia Bariátrica/métodos , Fenômenos Magnéticos , Estudos Retrospectivos , Resultado do Tratamento
18.
World J Gastroenterol ; 29(33): 5005-5013, 2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37731993

RESUMO

BACKGROUND: Although endoscope-assisted magnetic compression anastomosis has already been reported for colonic anastomosis, there is no report on a single-approach operation using the natural orifice. AIM: To design a deformable self-assembled magnetic anastomosis ring (DSAMAR) for colonic anastomosis for use in single-approach operation and evaluate its feasibility and safety through animal experiments. METHODS: The animal model for colonic stenosis was prepared by partial colonic ligation in eight beagles. The magnetic compression anastomosis of their colonic stricture was performed by endoscopically assisted transanal implantation of the DSAMAR. The anastomotic specimen, obtained 2 wk after the operation, was observed by both the naked eye and a light microscope. RESULTS: The DSAMAR was successfully inserted into the proximal end of colon stenosis through the anus. The DSAMAR of seven dogs was successfully transformed into rings, while that of the remaining dog was removed after the first deformation failed. The rings were successfully retransformed after optimization. All animals underwent colonic anastomosis using the DSAMAR. No device-related or procedure-related adverse events were observed. The colostomy specimens of the experimental dogs were obtained 2 wk after the operation. Both gross and histological observations showed good anastomotic healing. CONCLUSION: The DSAMAR is a safe and feasible option for the treatment of colon stenosis. Its specific deformation and self-assembly capability maximize the applicability of the minimally invasive treatment.


Assuntos
Endoscopia , Obstrução Intestinal , Animais , Cães , Constrição Patológica/cirurgia , Anastomose Cirúrgica , Fenômenos Magnéticos
19.
J Pediatr Surg ; 2023 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-37968150

RESUMO

BACKGROUND: To assess the feasibility of a deformable self-assembled magnetic anastomosis ring (DSAMAR) in the treatment of esophageal stenosis in beagle dogs via transoral access without temporary gastrostomy. METHODS: Experimental esophageal stenosis was created in 10 beagle dogs by partial cervical esophageal ligation. The DSAMAR was inserted into the distal esophagus via the narrow section of the esophagus using a gastroscope. A circular DSAMAR was placed in the proximal esophagus. The magnetic rings on both sides of the experimental stenosis automatically attracted each other. We then recorded the operation time, postoperative complications, anastomotic formation time, and magnetic ring discharge time. The dogs were euthanized 4 weeks postoperatively; subsequently, we obtained the esophageal anastomotic specimens and observed the anastomotic formation via the naked eye and by light microscopy. RESULTS: Our esophageal stenosis model produced reproducible stenoses in all dogs, which was confirmed via endoscopy and esophagography. DSAMAR was successfully implanted in all experimental animals under endoscopic and X-ray monitoring, and all linear DSAMARs were successfully transformed into rings. The magnets at both ends of the esophageal stenosis were automatically attracted. All animals survived until euthanasia. No complications, including esophageal perforation, bleeding, and gastrointestinal obstruction, were noted during the perioperative period. The mean operation time of endoscopic magnetic anastomosis was 15.6 ± 2.41 (range, 12-19) min. The mean esophageal anastomotic formation time was 8.8 ± 1.03 (range, 7-10) days, and the mean expulsion time of DSAMAR was 13.94 ± 2.88 (range, 10-19) days. Gastroscopy and esophagography were performed at 4 weeks postoperatively; the esophageal patency was good. Macroscopic observation of the esophageal anastomotic specimens revealed that the esophageal mucosal layer of the anastomosis had good continuity and the anastomosis was smooth. CONCLUSION: DSAMAR is a feasible option for magnetic recanalization of esophageal stricture via transoral access without temporary gastrostomy.

20.
Front Surg ; 10: 1253728, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37942002

RESUMO

Since the 1970s, magnetic force has been used to augment modern surgical techniques with the aims of minimizing surgical trauma and optimizing minimally-invasive systems. The majority of current clinical applications for magnetic surgery are largely centered around gastrointestinal uses-such as gastrointestinal or bilioenteric anastomosis creation, stricturoplasty, sphincter augmentation, and the guidance of nasoenteric feeding tubes. However, as the field of magnetic surgery continues to advance, the development and clinical implementation of magnetic devices has expanded to treat a variety of non-gastrointestinal disorders including musculoskeletal (pectus excavatum, scoliosis), respiratory (obstructive sleep apnea), cardiovascular (coronary artery stenosis, end-stage renal disease), and genitourinary (stricture, nephrolithiasis) conditions. The purpose of this review is to discuss the current state of innovative magnetic surgical devices under clinical investigation or commercially available for the treatment of non-gastrointestinal disorders.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa