RESUMO
BACKGROUND: Both running horizontal mattress (HM) and running subcuticular (SQ) suturing techniques have been suggested to be superior to other running cuticular suturing techniques. These 2 techniques have not been directly compared. OBJECTIVE: To compare cosmetic outcomes between a running HM and a running SQ technique in a split scar model following linear closure of trunk and extremity defects. METHODS: Fifty patients were enrolled in a randomized, evaluator-blinded, split-scar study. One side of the surgical wound was randomized to receive one intervention (HM vs SQ) with the other side receiving the alternate intervention. The primary outcome was the Patient and Observer Scar Assessment Scale (POSAS) score at a minimum of 3 months postoperatively. RESULTS: Observer POSAS sum of components was 19.49 and 17.76 for HM and SQ, respectively (P = .14). The mean score for patient overall opinion was 4.71 for HM and 3.50 for the SQ technique (P = .02). Overall opinion scores of evaluators were 3.87 and 3.29 for HM and SQ, respectively (P = .03). LIMITATIONS: Single-center study of a relatively homogenous population. CONCLUSION: Although there was no significant difference in the sum of POSAS components between HM and SQ (P = .14), both patients and evaluators had a superior overall opinion of the SQ-treated side (patient P = .02, evaluator P = .03).
Assuntos
Cicatriz , Estética , Técnicas de Sutura , Tronco , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Cicatriz/prevenção & controle , Cicatriz/etiologia , Adulto , Idoso , Método Simples-Cego , Extremidades/cirurgia , Extremidades/lesões , Resultado do TratamentoRESUMO
PURPOSE: To assess the efficacy of adding Ahmed's sub-flap mattress suture to deep sclerectomy (DS). METHODS: Forty eyes with open angle glaucoma were assigned randomly into two groups: Group A: underwent DS with Ahmed's sub-flap mattress suture. Group B: underwent conventional DS. Patients were followed up closely for 6 months with serial IOP measurements and ultrasound biomicroscopy (UBM) was used to assess the surgical site functionally and anatomically at the first and sixth month. RESULTS: Adding Ahmed's sub-flap mattress suture improved the IOP lowering effect of DS significantly from 43% in group B to 53% in group A at 6-month (p = 0.027). IOP in group A was at 1 week, 1 month and 6-month visits (7.9 ± 1.3, 11.7 ± 2.2 and 13.3 ± 1.9 mmHg respectively) compared to group B (10.1 ± 4.6, 14.1 ± 5.2 and 16.8 ± 4.1 mmHg respectively) (p = 0.025, 0.041 and 0.001 respectively). UBM parameters were significantly larger in group A at 1 and 6 months. Strong statistically significant negative correlations were established between IOP and all the UBM parameters apart from intrascleral lake height at the first and sixth month (p < 0.01 in all of them). Finally, significant correlations were found between IOP at 6 months and whole bleb anteroposterior length and height at 1 month (p = 0.001). CONCLUSION: Adding Ahmed's sub-flap mattress suture to routine DS is an effective economical addition that will enhance the IOP lowering effect of DS. Also, assessment of the bleb by UBM is useful in predicting the success of deep sclerectomy surgery.
RESUMO
BACKGROUND: Pressure injuries are a common and serious issue for bedridden residents in long-term-care facilities. Areas of bony prominences, such as the scapula, sacrum, and heels, are more likely to develop pressure injuries. The management of pressure injury wounds include dressing changes, repositioning, away from moisture, decreasing the occurrence of friction and shear, and more. Some supportive surfaces are also used for pressure injury cases such as gel pads, alternating pressure air mattresses, and air-fluidized beds. The aim of this case study was to determine whether the use of an artificial intelligent mattress can improve a nursing home resident with prolonged pressure injury. CASE PRESENTATION: A retrospective study design was conducted for this case study. A 79-year-old male developed a pressure injury in the sacrum. His pressure injury was initially at stage 4, with a score of 12 by the Braden scale. The PUSH score was 16. During 5.5 months of routine care plus the use of the traditional alternative air mattress, in the nursing home, the wound stayed in stage 3 but the PUSH score increased up to 11. An artificial intelligence mattress utilizing 3D InterSoft was used to detect the bony prominences and redistribute the external pressure of the skin. It implements a color guided schematic of 26 colors to indicate the amount of pressure of the skin. RESULTS: The wound size was decreased and all eczema on the resident's back diminished. The PUSH score was down to 6, as the artificial intelligent mattress was added into the routine care. The staff also reported that the resident's quality of sleep improved and moaning decreased. The hemiplegic side is at greater risk of developing pressure injury. CONCLUSIONS: This novice device appeared to accelerate wound healing in this case. In the future, more cases should be tested, and different care models or mattress can be explored.
Assuntos
Úlcera por Pressão , Masculino , Humanos , Idoso , Úlcera por Pressão/prevenção & controle , Úlcera por Pressão/epidemiologia , Estudos Retrospectivos , Inteligência Artificial , Cicatrização , LeitosRESUMO
BACKGROUND: The challenge of preventing in-patient falls remains one of the most critical concerns in health care. OBJECTIVE: This study aims to investigate the effect of an integrated Internet of Things (IoT) smart patient care system on fall prevention. METHODS: A quasi-experimental study design is used. The smart patient care system is an integrated IoT system combining a motion-sensing mattress for bed-exit detection, specifying different types of patient calls, integrating a health care staff scheduling system, and allowing health care staff to receive and respond to alarms via mobile devices. Unadjusted and adjusted logistic regression models were used to investigate the relationship between the use of the IoT system and bedside falls compared with a traditional patient care system. RESULTS: In total, 1300 patients were recruited from a medical center in Taiwan. The IoT patient care system detected an average of 13.5 potential falls per day without any false alarms, whereas the traditional system issued about 11 bed-exit alarms daily, with approximately 4 being false, effectively identifying 7 potential falls. The bedside fall incidence during hospitalization was 1.2% (n=8) in the traditional patient care system ward and 0.1% (n=1) in the smart ward. We found that the likelihood of bedside falls in wards with the IoT system was reduced by 88% (odds ratio 0.12, 95% CI 0.01-0.97; P=.047). CONCLUSIONS: The integrated IoT smart patient care system might prevent falls by assisting health care staff with efficient and resilient responses to bed-exit detection. Future product development and research are recommended to introduce IoT into patient care systems combining bed-exit alerts to prevent inpatient falls and address challenges in patient safety.
Assuntos
Acidentes por Quedas , Internet das Coisas , Segurança do Paciente , Humanos , Acidentes por Quedas/prevenção & controle , Segurança do Paciente/estatística & dados numéricos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Taiwan , Idoso de 80 Anos ou mais , Assistência ao Paciente/métodos , AdultoRESUMO
BACKGROUND: Hypothermia is a common perioperative problem that can lead to severe complications. We evaluated whether a heated mattress (HM) is superior to a warm air blanket (WA) in preventing perioperative hypothermia in patients undergoing total hip arthroplasty (THA) or total knee arthroplasty (TKA). METHODS: A retrospective cohort study was performed in a teaching hospital and data were collected for all patients undergoing THA or TKA between January 1, 2015 and May 1, 2022. We used logistic and linear regressions to analyze hypothermia occurrence and important complications. Results were adjusted for confounders and time, and was present in all subgroups and after imputation of missing data. RESULTS: In total, 4,683 of 5,497 patients had information on type of heating. We found more perioperative hypothermia in patients treated with an HM compared to a WA for both THA (odds ratio-adjusted 1.42 [1.0 to 1.6] P = .06) and TKA (odds ratio-adjusted 2.10 [1.5 to 3.0] P < .01). There was no difference in postoperative infections between groups (all between 0.5% and 1.3%). Patients who had an HM significantly stayed longer in the postoperative ward (a mean difference of 4 [TKA] to 6 [THA] minutes, P < .01), but there was no difference in hospital stay. CONCLUSION: A WA is superior compared to an HM in preventing perioperative hypothermia, with no increased risk of complications. Patients who have an HM stayed longer at the postoperative ward, potentially because of higher hypothermia rates. Therefore, it is suggested to use a WA instead of an HM.
Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Hipotermia , Humanos , Hipotermia/etiologia , Hipotermia/prevenção & controle , Estudos Retrospectivos , Artroplastia do Joelho/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Hospitais de EnsinoRESUMO
OBJECTIVE: A feasibility study to test the proposed methodology for a larger randomised control trial was conducted, investigating the comparative effectiveness of the two types of pressure management support surfaces with regards to healing pressure injuries (PI). A secondary objective was to provide insights into the user acceptability of the two types of pressure management support surfaces. METHOD: A randomised control feasibility study was conducted in a community health setting in Canberra, Australia. Patients aged ≥65 years with an existing Stage 2 PI who slept in a bed were eligible. Participants were randomised to either the active mattress group or the reactive mattress group for use on their bed. All participants received standard wound care by community nursing staff and were provided an air-flotation cushion for use when not in bed. Photographs were taken and used for blind assessment of wound healing. Secondary information was gathered through a survey regarding user acceptability of the support surfaces and changes in habits regarding PI prevention strategies. RESULTS: In total, five patients were recruited, with one passing away prior to mattress allocation. Results were inconclusive with regards to comparative effectiveness and user acceptability due to the small sample size; however, secondary data indicated an increasing implementation of PI prevention strategies. CONCLUSION: This study confirmed the need for further high quality research comparing reactive and active pressure mattresses. Trends indicate the importance of including education on PI prevention strategies to promote changes in behaviour. Changes to the proposed methodology will be made to increase recruitment in the primary study.
Assuntos
Leitos , Úlcera por Pressão , Cicatrização , Humanos , Úlcera por Pressão/prevenção & controle , Projetos Piloto , Idoso , Masculino , Feminino , Idoso de 80 Anos ou mais , Estudos de Viabilidade , AustráliaRESUMO
Assisting immobile individuals with regular repositioning to adjust pressure distribution on key prominences such as the back and buttocks is the most effective measure for preventing pressure ulcers. However, compared to active self-repositioning, passive assisted repositioning results in distinct variations in force distribution on different body parts. This incongruity can affect the comfort of repositioning and potentially lead to a risk of secondary injury, for certain trauma or critically ill patients. Therefore, it is of considerable practical importance to study the passive turning comfort and the optimal turning strategy. Initially, in this study, the load-bearing characteristics of various joints during passive repositioning were examined, and a wedge-shaped airbag configuration was proposed. The airbags coupled layout on the mattress was equivalently represented as a spring-damping system, with essential model parameters determined using experimental techniques. Subsequently, different assisted repositioning strategies were devised by adjusting force application positions and sequences. A human-mattress force-coupled simulation model was developed based on rigid human body structure and equivalent flexible springs. This model provided the force distribution across the primary pressure points on the human body. Finally, assisted repositioning experiments were conducted with 15 participants. The passive repositioning effectiveness and pressure redistribution was validated based on the simulation results, experimental data, and questionnaire responses. Furthermore, the mechanical factors influencing comfort during passive assisted repositioning were elucidated, providing a theoretical foundation for subsequent mattress design and optimization of repositioning strategies.
Assuntos
Úlcera por Pressão , Humanos , Úlcera por Pressão/prevenção & controle , LeitosRESUMO
BACKGROUND: Arthroscopic Bankart repair is the most common procedure in patients with anterior shoulder instability. Various repair techniques using suture anchors have been used to improve the strength of fixation and surgical outcomes in arthroscopic Bankart surgery. However, evidence regarding which method is superior is lacking. This systematic review and meta-analysis study was designed to compare the biomechanical results of simple versus horizontal mattress versus double-row mattress for Bankart repair. METHODS: A systematic search of the MEDLINE, Embase, and Cochrane Library databases was performed to identify comparative biomechanical studies comparing the simple, horizontal mattress, and double-row techniques commonly used in Bankart repair for anterior shoulder instability. Biomechanical results included the ultimate load to failure, stiffness, cyclic displacement, and mode of failure after the ultimate load. The methodological quality was assessed based on the Quality Appraisal for Cadaveric Studies (QUACS) scale for biomechanical studies. RESULTS: Six biomechanical studies comprising 125 human cadavers were included in this systematic review. In biomechanical studies comparing simple and horizontal mattress repair and biomechanical studies comparing simple and double-row repair, there were no significant differences in the ultimate load to failure, stiffness, or cyclic displacement between the repair methods. The median QUACS scale was 11.5 with a range from 10 to 12, indicating a low risk of bias. CONCLUSION: There was no biomechanically significant difference between the simple, horizontal mattress, and double-row methods in Bankart repair. Clinical evidence such as prospective randomized controlled trials should be conducted to evaluate clinical outcomes according to the various repair methods. LEVEL OF EVIDENCE: Systematic review, Therapeutic level IV.
Assuntos
Instabilidade Articular , Articulação do Ombro , Humanos , Estudos Prospectivos , Amputação Cirúrgica , ArtroplastiaRESUMO
Biomimetic superhydrophobic surfaces display many excellent underwater functionalities, which attribute to the slippery air mattress trapped in the structures on the surface. However, the air mattress is easy to collapse due to various disturbances, leading to the fully wetted Wenzel state, while the water filling the microstructures is difficult to be repelled to completely recover the air mattress even on superhydrophobic surfaces like lotus leaves. Beyond superhydrophobicity, here we find that the floating fern, Salvinia molesta, has the superrepellent capability to efficiently replace the water in the microstructures with air and robustly recover the continuous air mattress. The hierarchical structures on the leaf surface are demonstrated to be crucial to the recovery. The interconnected wedge-shaped grooves between epidermal cells are key to the spontaneous spreading of air over the entire leaf governed by a gas wicking effect to form a thin air film, which provides a base for the later growth of the air mattress in thickness synchronously along the hairy structures. Inspired by nature, biomimetic artificial Salvinia surfaces are fabricated using 3D printing technology, which successfully achieves a complete recovery of a continuous air mattress to exactly imitate the superrepellent capability of Salvinia leaves. This finding will benefit the design principles of water-repellent materials and expand their underwater applications, especially in extreme environments.
Assuntos
Gleiquênias/química , Gleiquênias/ultraestrutura , Materiais Biomiméticos/síntese química , Materiais Biomiméticos/química , Gleiquênias/anatomia & histologia , Interações Hidrofóbicas e Hidrofílicas , Nelumbo/química , Epiderme Vegetal/ultraestrutura , Folhas de Planta/anatomia & histologia , Folhas de Planta/química , Folhas de Planta/ultraestrutura , Impressão Tridimensional , Propriedades de SuperfícieRESUMO
OBJECTIVE: Our aim was to measure the effectiveness of home healthcare pressure ulcer (PU) prevention devices (PUPDs) for at-risk patients after hospital discharge in France. METHOD: We conducted a retrospective analysis of PU-associated hospitalisations based on the French medico-administrative database (Système National des Données de Santé, SNDS), which covers the entire French population. All adults >70 years of age, hospitalised from 1 July to 31 December 2015, and equipped with a medical bed at home, were included. Follow-up was for a maximum of 18 months. Propensity score matching allowed the comparison of PUPD equipped and non-equipped groups (No-PUPD), considering sociodemographic characteristics and other factors. RESULTS: The study included 43,078 patients. Of this population, 54% were PUPD patients and 46% No-PUPD. After matching, PUPD patients had significantly fewer PUs than No-PUPD patients (5.5% versus 8.9%, respectively; p<0.001). The adoption of PUPD reduced by 39% the risk of a PU in hospital. Patients equipped within the first 30 days at home after hospitalisation had fewer PUs than those equipped later (4.8% versus 5.9%, respectively). The estimated PUPD use costs represented 1% of total healthcare expenditure per patient during the study period. CONCLUSION: The study results demonstrated the effectiveness of the adoption of mattress toppers or prevention mattresses in reducing PU occurrence in patients aged >70 years of age. A short delay in PUPD delivery appeared to have a real impact in the medical setting. Future research on a larger population might provide more evidence on the appropriate support and timeframe to choose based on risk assessment.
Assuntos
Alta do Paciente , Úlcera por Pressão , Adulto , Humanos , Idoso , Úlcera por Pressão/prevenção & controle , Estudos Retrospectivos , Hospitais , SupuraçãoRESUMO
OBJECTIVE: Effective pressure management for individuals is critical for hospital and community-based care, to prevent the occurrence of pressure ulcers. This study explores the impact of a new mattress and topper solution on interface pressure and comfort during supine lying. METHOD: In this quantitative, healthy cohort study, patient-surface interface pressures were calculated for three mattresses (a standard hospital mattress, a new mattress solution (Levitex Foams Ltd., UK) and a dynamic air flow mattress) with and without an innovative topper solution (Levitex Foams Ltd., UK). Subjective comfort, contact surface area, peak and mean pressure and peak pressure index (head, sacrum, heels) were calculated for all mattress conditions for a 21-minute period. RESULTS: A total of 27 healthy volunteers took part in this study. The new mattress solution decreased peak pressure significantly compared with the hospital and air mattresses (p<0.04). Lower peak pressures were observed for the hospital mattress compared with the dynamic air flow mattress. The new mattress solution improved comfort and significantly lowered (>30%; p≤0.005) heel and head pressure compared with the other surfaces. Both hospital and air mattresses significantly reduced pressure and improved comfort with the addition of the new topper solution (p<0.05). CONCLUSION: The new mattress solution used in this study offers a potentially improved pressure management solution for individuals. Implementation of the topper may also help to improve pressure management when used with existing standard or dynamic air flow mattresses.
Assuntos
Leitos , Úlcera por Pressão , Humanos , Estudos de Coortes , Sacro , Úlcera por Pressão/prevenção & controle , Úlcera por Pressão/epidemiologia , Região SacrococcígeaRESUMO
OBJECTIVE: Prevention of pressure injuries (PI) is a public health issue. Among the preventive measures, the use of support surfaces adapted to the risk of PI occurrence is recommended. This study aimed to report the incidence of PIs in patients at medium-to-high risk of occurrence of PIs and using a new non-motorised automated decompression air mattress combined with other recommended PI prevention measures. METHOD: An observational, national, multicentre, prospective, non-comparative study, with a follow-up period of 35 days was conducted. Patients at medium-to-high risk of PIs and without PIs at baseline were included if they were lying on a specific non-powered automated decompression air mattress. The primary outcome was the percentage of patients who developed at least one category 2 or more severe PI of the sacrum, backbone or heel between day 0 and day 35. RESULTS: In total, 81 patients were included from four participating centres. There was one report of a patient with a PI that fitted within the definition of the primary outcome, meaning an incidence of 1.2% (95% confidence interval (CI) 0-6.7%). More than 80% of patients rated the overall comfort and the stability of the non-motorised automated decompression air mattress as satisfactory or very satisfactory. In more than 80% of cases, the healthcare teams found the use of the mattress to be easy or very easy. CONCLUSION: This study has shown that in combination with other preventive measures, the use of a specific non-motorised air mattress with automated decompression is associated with a low incidence of PIs in patients with medium-to-high risk of occurrence of PIs.
Assuntos
Úlcera por Pressão , Humanos , Úlcera por Pressão/prevenção & controle , Estudos Prospectivos , Leitos , Sacro , DescompressãoRESUMO
Bed is often the personal care unit in hospitals, nursing homes, and individuals' homes. Rich care-related information can be derived from the sensing data from bed. Patient fall is a significant issue in hospitals, many of which are related to getting in and/or out of bed. To prevent bed falls, a motion-sensing mattress was developed for bed-exit detection. A machine learning algorithm deployed on the chip in the control box of the mattress identified the in-bed postures based on the on/off pressure pattern of 30 sensing areas to capture the users' bed-exit intention. This study aimed to explore how sleep-related data derived from the on/off status of 30 sensing areas of this motion-sensing mattress can be used for multiple layers of precision care information, including wellbeing status on the dashboard and big data analysis for living pattern clustering. This study describes how multiple layers of personalized care-related information are further derived from the motion-sensing mattress, including real-time in-bed/off-bed status, daily records, sleep quality, prolonged pressure areas, and long-term living patterns. Twenty-four mattresses and the smart mattress care system (SMCS) were installed in a dementia nursing home in Taiwan for a field trial. Residents' on-bed/off-bed data were collected for 12 weeks from August to October 2021. The SMCS was developed to display care-related information via an integrated dashboard as well as sending reminders to caregivers when detecting events such as bed exits and changes in patients' sleep and living patterns. The ultimate goal is to support caregivers with precision care, reduce their care burden, and increase the quality of care. At the end of the field trial, we interviewed four caregivers for their subjective opinions about whether and how the SMCS helped their work. The caregivers' main responses included that the SMCS helped caregivers notice the abnormal situation for people with dementia, communicate with family members of the residents, confirm medication adjustments, and whether the standard care procedure was appropriately conducted. Future studies are suggested to focus on integrated care strategy recommendations based on users' personalized sleep-related data.
Assuntos
Demência , Casas de Saúde , Humanos , Hospitais , Postura , LeitosRESUMO
Mattresses' pressure relief performance and comfort largely affect sleep quality. Mattress filling materials have been proven to affect the interface pressure distribution and comfort, but the effect of mattress structure is unclear. In this paper, the interface pressure distribution and subjective comfort of 10 subjects were assessed in the different bedding layer structures of mattresses, after mattress support performance was tested. The results show that the mattresses with bedding material hardness gradually increasing from the top layer to the bottom layer (BMH-ITTB) structure have a softer surface layer, a better support core layer, and higher fitness. This enables the mattress to achieve a better decompression effect. The low-pressure area (PAI≤0.67kPa) increased, while the high-pressure area (PAI≥2.67kPa and PAI≥4.00kPa), maximum pressure (P95), average pressure (P50), and pressure index (PI) decreased. This also enables the mattress to achieve higher subjective comfort scores.
Assuntos
Leitos , Úlcera por Pressão , Humanos , Roupas de Cama, Mesa e Banho , DurezaRESUMO
Support surfaces are the most important pressure ulcer/injury prevention technology available to clinicians for protecting their at-risk patients. A hybrid support surface marries the benefits of reactive and active support surfaces, by using high-quality foam material inside inflatable air cells. When used in its "static mode", it is a constant low air pressure mattress which delivers pressure redistribution in response to patient bodyweight and movements, by maximising the immersion and envelopment performance of the support surface. When used in its powered "dynamic mode", this system further delivers alternating pressure care via the connected foam and air cells. Modes of action of hybrid support surfaces were never studied quantitatively before, excluding through the limited scope of interface pressure mapping. In this work, we developed a novel computational modelling framework and simulations to visualise and quantify the state of soft tissue loading at the buttocks of a supine patient positioned on a hybrid support surface, in both the static and dynamic modes. We found that the dynamic mode effectively shifts deep concentrated soft tissue loading from under the sacral bone (towards the sacral promontory) to the tip of the sacrum (coccyx) and vice versa, and thereby, generates a deep tissue offloading effect.
Assuntos
Úlcera por Pressão , Humanos , Úlcera por Pressão/prevenção & controle , Pacientes , Sacro , Região Sacrococcígea , LeitosRESUMO
A rod-shaped, Gram-negative staining strain, FBM22T, was isolated from a microbial fermentation bed substrate from a pig farm. Its colonies appeared yellow and were 0.5-1.2 mm in diameter. Cells were 0.3-0.5 µm wide, 0.5-0.83 µm long. Optimal growth occurred at 30 °C and pH 7.0-8.0; NaCl was not required for growth. The strain performed denitrification and nitrate reduction functions. And it could produce catalase. FBM22-1T utilized the following organic substrates for growth: tyrosine, glutamic acid, D-glucose, and galactose. The novel isolate could degrade 2-nitropropane as carbon and nitrogen source. The dominant respiratory quinone was Q-10. The major polar lipids were diphosphatidylglycerol, phosphatidylcholine and phosphatidylethanolamine. C18:1 ω7c, C16:1 ω7c and/ or C16:1 ω6c, and C14:0 2-OH were the major (≥ 8%) fatty acids. The G+C content was 56.8 mol%. FBM22T was found to be a member of the genus Sphingopyxis in the family Sphingomonadaceae of the class Alphaproteobacteria. It had the highest sequence similarity with the type strains Sphingopyxis terrae subsp. ummariensis UI2T (96.47%) and Sphingopyxis terrae subsp. terrae NBRC 15098T (96.40%). Furthermore, FBM22T had 18.7% and 18.4% relatedness (based on digital DNA-DNA hybridization) with its two relatives (S. terrae subsp. ummariensis UI2T and S. terrae subsp. terrae NBRC 15098T). The morphological, physiological, and genotypic differences identified in this study support the classification of FBM22T as a novel species within the genus Sphingopyxis, for which the name Sphingopyxis yananensis sp. nov. is proposed. The type strain is FBM22T (= KCTC 82290T = CCTC AB2020286T).
Assuntos
Sphingomonadaceae , Animais , Técnicas de Tipagem Bacteriana , DNA Bacteriano/genética , Ácidos Graxos/análise , Fermentação , Nitroparafinas , Fosfolipídeos/química , Filogenia , Propano/análogos & derivados , RNA Ribossômico 16S/genética , Análise de Sequência de DNA , SuínosRESUMO
BACKGROUND: Most trauma systems and traumatic spinal injury guidelines mandate spinal stabilization from the site of injury to a radiological confirmation or refutal of spinal injury. Vacuum mattresses have been advocated for patients in need of prehospital spinal stabilization. PURPOSE: To investigate the effect of different vacuum mattresses on standard resuscitation bay conventional radiography of chest and pelvis, especially regarding artefacts. MATERIAL AND METHODS: We used a mobile X-ray machine to perform chest and pelvic conventional radiography on an anthropomorphic whole-body phantom with a trauma transfer board, three different vacuum mattresses, and without any stabilization device. The vacuum mattresses were investigated in activated, deactivated, and stretched after deactivated states. Two radiologists assessed the artefacts independently. Agreement was measured using kappa coefficient. RESULTS: All radiographs were of good technical quality and fully diagnostic. With the exception of one disagreed occurrence, artefacts were seen to hamper clinical judgment exclusively with activated vacuum mattresses. There was substantial agreement on artefact assessment. The observed agreement was 0.82 with a kappa coefficient of 0.71. The first vacuum mattress caused no artefacts hampering with clinical judgment. CONCLUSION: Our study concludes that it is feasible to maintain some vacuum mattresses through resuscitation bay conventional radiography of chest and pelvis. They do not result in artefacts hampering with clinical judgment. Our vacuum mattress No. 1 is recommendable for this purpose. Together with our previous findings our present results indicate that some vacuum mattresses may be used throughout the initial resuscitation bay assessment and CT examination.
Assuntos
Traumatismos da Coluna Vertebral , Estudos de Viabilidade , Humanos , Imobilização , Radiografia , Coluna Vertebral , Raios XRESUMO
BACKGROUND: The most common complications of myomectomy are intraoperative hemorrhage and postoperative adhesion. The key point to overcome this problem is to improve suture quality. However, to date, there is still no consensus on the optimal method of uterine repair. In this study, we explored the effectiveness and feasibility of single-site laparoscopic parallel mattress sutures to reduce intraoperative bleeding and postoperative adhesion. METHODS: A retrospective cohort analysis was performed, according to the STROBE guidelines, on 124 patients with intramural fibroids admitted between May 2020 and April 2021. The cases were divided into two groups based on the description of the uterine incision suture in the surgical records, including 68 cases in the parallel mattress suture (PMS) group and 56 cases in the simple continuous suture (SCS) group. Operation-related indicators, bleeding indicators, surgical complications, scar reduction index 1 month after surgery, and the incidence of chronic pelvic pain 6 months after the surgery were observed. Independent sample t-tests and Mann-Whitney U tests were performed for the measurement data, and Pearson Chi-square tests were performed for count data. Statistical significance was set at P < 0.05. RESULTS: There was no significant difference in the baseline characteristics between the two groups. All operations were performed under transumbilical single-site laparoscopy without conversion. Compared to the SCS group, the PMS group had earlier postoperative anal exhaust (14.3 ± 6.7 h vs. 19.2 ± 9.6 h, P = 0.002), fewer postoperative hemoglobin drops (7.6 ± 3.7 g/L vs. 11.6 ± 4.3 g/L, P = 0.000), smaller uterine scars (3.7 ± 1.9 cm vs. 5.2 ± 1.8 cm, P = 0.000), and a larger uterine scar reduction index (50.2% vs. 31.0%, P = 0.000) one month after surgery and less chronic pelvic pain 6 months after surgery (2.9% vs. 12.5%, P = 0.016). No difference was found in auxiliary trocar usage, transfusion rate, operation time, hospital stay, or perioperative complications between the two groups. CONCLUSION: Seromuscular parallel mattress sutures during myomectomy can prevent pinhole errhysis of the uterine incision, achieve complete serosal and aesthetic incisions, and reduce postoperative chronic pelvic pain. It is effective and feasible to complete a parallel mattress suture during myomectomy via single-site laparoscopy. Further prospective studies are required to determine its efficacy as well as pregnancy outcomes.
Assuntos
Laparoscopia , Leiomioma , Miomectomia Uterina , Neoplasias Uterinas , Perda Sanguínea Cirúrgica , Cicatriz , Feminino , Humanos , Laparoscopia/métodos , Leiomioma/cirurgia , Dor Pélvica/cirurgia , Estudos Retrospectivos , Técnicas de Sutura , Suturas , Miomectomia Uterina/métodos , Neoplasias Uterinas/cirurgiaRESUMO
BACKGROUND: Pressure ulcers are a risk for bedridden patients and various supports exist to prevent them. The Pressure Relief Index (PRI) evaluates pressure relief of dynamic mattresses over time. This study compared the PRI of the SUMMIT mattress (AKS-France) and the NIMBUS 3 (HNE Medical). METHODS: In this non-blinded, randomized, crossover, non-inferiority study, patients aged ≥60 with a BMI of 16-35 kg/m2, predominantly confined to bed, able to walk with aid and with pelvic symmetry were recruited from a hospital rehabilitation department from March-April 2012. Exclusion criteria included past or present pressure ulcers, inability to remain supine and deep vein thrombosis. Peak pressures of the sacrum were recorded at 0.1 Hz during a single complete 10-min inflating cycle on both mattresses, with the order determined via electronic randomization allocation. RESULTS: Thirty-one subjects were included and randomized; with 14 finally analyzed in the SUMMIT-NIBMUS 3 order group and 16 in the NIMBUS 3-SUMMIT group. The difference in PRI <30 mmHg between the two mattresses was 13.2% [0.3-26.1] (p < 0.05), allowing a non-inferiority - superiority switch. The SUMMIT mattress demonstrated a significantly higher percentage of time <30 mmHg (p = 0.0454). No significant difference in mean minimal pressure was seen (p = 0.3231) and mean maximal pressure was in favor of SUMMIT mattress (p = 0.0096). BMI did not affect pressure profile. There were no adverse events. CONCLUSIONS: Evaluated by the PRI, the SUMMIT mattress had a better interface pressure profile than the NIMBUS 3 in older patients. The PRI is a promising tool for clinical decision-making and research, warranting validation.
Assuntos
Úlcera por Pressão , Idoso , Leitos , França , Humanos , Úlcera por Pressão/prevenção & controle , Sacro , Higiene da PeleRESUMO
BACKGROUND: The type of suture used in periodontal surgery can affect post-surgical complications. This study aimed to compare simple with cross-mattress sutures for nondisplaced flaps of the maxillary molar region. METHODS: This randomized controlled trial included 32 candidates of nondisplaced flap surgery of the maxillary molar region referred to the private office of a periodontist in Bandar Abbas, Iran from January 21 to May 4, 2020. First, the patients' age, sex, and plaque index were recorded. Then, they were randomized into two equal groups. In the first group, the interdental suturing was done using simple sutures with 4-0 vicryl threads, and in the second group, interdental suturing was performed using cross-mattress sutures with the same threads. The primary outcome was suture time, including the duration of the first suture and the total duration of all sutures. The secondary outcomes were bleeding on probing and the requirement of supplementary sutures immediately after the surgery, as well as the gingival index (at suture removal and one month after surgery). RESULTS: The two groups were comparable regarding age, sex, and plaque index. The first suture duration was significantly longer in the simple group compared to the cross-mattress group (P < 0.001); however, the total suture time did not differ between groups. Moreover, a significantly higher number of patients in the simple group required supplementary sutures (50% vs. 6.3%, P = 0.006). There was no significant difference between groups regarding bleeding on probing and gingival index (at suture removal and one month after surgery). CONCLUSIONS: Cross-mattress sutures were superior to simple sutures in terms of supplementary suture requirement for nondisplaced flaps of the maxillary molar region, while the two suturing techniques were alike regarding total suture time, gingival index, and probing on bleeding. TRIAL REGISTRATION: Iranian Registry of Clinical Trials (IRCT), IRCT20191224045882N1. Registered 08/02/2020. Registered while recruiting, https://www.irct.ir/trial/44754 .