Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 138: 105572, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36435033

RESUMO

Joint replacements have become one of the most common orthopedic procedures due to the significant demands of retaining functional mobility. While these procedures are of great value to patients, there are some limitations. Durability is the most important limitation associated with joint replacement that needs to be addressed due to the increasing number of younger patients. Titanium is a commonly used implant material which has high biocompatibility, high strength-to-density ratio, and high corrosion resistance. However, current titanium implants have poor wear resistance which shortens their lifespan. In this study, microscale dimples with four different dimple shapes (circular, triangular, square, and star) of similar sizes to the pores found in natural articular cartilage were fabricated on titanium disks to improve implant lubrication and reduce wear. Biotribology tests were performed on dimpled and non-dimpled titanium disks in a condition similar to that inside of a patient's body. It was shown that dimpling the titanium disks optimized the lubricant film formation and decreased the wear rate significantly while also reducing the coefficient of friction (COF). The star-shaped dimples had the lowest COF and almost no detectable wear after 8 h of testing. To investigate whether dimpling increased bacterial colonization due to increased surface area, and to determine whether any increase could be limited by coating with antibacterial materials, bacterial colonization with Staphylococcus aureus was tested with non-dimpled and star-shaped dimpled titanium disks with and without coating with polydopamine (PDA), silver (Ag) nanoparticles (NPs), and PDA + Ag NPs. It was found that dimpling did not increase bacterial colonization, and that coating with PDA, Ag NPs, or PDA + Ag NPs did not decrease bacterial colonization. Nevertheless, we conclude that star-shaped dimpled titanium surfaces have potential utility as more durable orthopedic implants.


Assuntos
Nanopartículas , Titânio , Humanos , Antibacterianos , Fricção , Staphylococcus aureus , Propriedades de Superfície , Materiais Revestidos Biocompatíveis
2.
Micromachines (Basel) ; 12(9)2021 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-34577750

RESUMO

Through-mask electrochemical micromachining (TMEMM) is a promising method to prepare micro dimples on the surface of metallic parts. However, the workpiece is machined one by one in traditional TMEMM. This paper introduced bidirectional pulse to TMEMM to improve the machining efficiency. Two masked workpieces were placed face to face, and connected to the ends of the bidirectional pulse power supply. Along with the change of the pulse direction, the polarities of the two workpieces were interchanged periodically, and micro dimples could be prepared on both workpieces at one time. The simulation and experiment results indicated that with bidirectional pulse mode, micro dimples with same the profile can be prepared on two workpieces at one time, and the dimension of micro dimple was smaller than that with unidirectional pulse mode. In bidirectional pulse current, the pulse frequency and pulse duty cycle played an important role on the preparation of micro dimple. With high pulse frequency and low pulse duty cycle, it is useful to reduce the undercut of micro dimple and improve the machining localization. With the pulse duty cycle of 20% and pulse frequency of 10 kHz, micro dimples with etch factor (EF) of 3 were well prepared on both workpieces surface.

3.
Materials (Basel) ; 12(10)2019 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-31096588

RESUMO

Advances in heavy-duty diesel engine designs place higher demands on the friction and wear performance of the piston ring and cylinder liner (PRCL) interface. The potential of using micro-textures machined on the whole stroke of a cast-iron cylinder liner was investigated in this work. A set of running-in and starved lubrication experiments was performed using a custom reciprocating test rig that imparts a combination of combustion-level pressures and the resulting impacts. Based on a comparison of micro-dimple parameters, the friction coefficient for the running-in period at the shocking dead center was the smallest at a designed combination of 1000-µm diameter, 22% area fraction, and arrangement with half-radius intersecting distance of two adjacent micro-dimple columns. The non-scuffing time under starvation was the longest at a designed combination of the following parameters: 800 µm diameter, 22% area fraction, and quarter-radius intersecting distance arrangement. From finite element analysis, it was found that stress concentrates at the micro-dimple periphery and at the connections between adjacent micro-dimples. However, surface topography examination showed that scuffing initiates in the non-dimpled regions between the micro-dimpled columns rather than at their edges. Finally, under reciprocating motion, micro-dimples can collect wear debris to inhibit further propagation of scuffing in the micro-dimpled region.

4.
J Mech Behav Biomed Mater ; 81: 120-129, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29501964

RESUMO

This study evaluates the impact of dimple shapes on lubricant film formation in artificial hip joints. Micro-dimples with 20-50 µm lateral size and 1 ±â€¯0.2 µm depths were fabricated on CrCoMo hip joint femoral heads using a picosecond laser. Tribological studies were performed using a pendulum hip joint simulator to apply continuous swing flexion-extension motions. The results revealed a significantly enhanced lubricant film thickness (≥ 500 nm) with micro-dimpled prosthesis heads at equilibrium position after the lubricant film has fully developed. The average lubricant film thickness of dimpled prostheses with square- and triangular-shaped dimple arrays over time is about 3.5 that of the non-dimpled prosthesis (204 nm). Remarkably, the prosthesis with square-shaped dimple arrays showed a very fast lubricant film formation reaching their peak values within 0.5 s of pendulum movement, followed by prosthesis with triangular-shaped dimple arrays with a transition period of 42.4 s. The fully developed lubricant film thicknesses (≥ 700 nm) are significantly higher than the surface roughness (≈ 25 nm) demonstrating a hydrodynamic lubrication. Hardly any scratches appeared on the post-experimental prosthesis with square-shaped dimple array and only a few scratches were found on the post-experimental prosthesis with triangular-shaped dimple arrays. Thus, prostheses with square-shaped dimple arrays could be a potential solution for durable artificial hip joints.


Assuntos
Prótese de Quadril , Fenômenos Mecânicos , Líquido Sinovial/metabolismo , Animais , Bovinos
5.
Micromachines (Basel) ; 9(10)2018 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-30424468

RESUMO

In this paper, a novel single-driven ultrasonic elliptical vibration cutting (SDUEVC) device with a succinct structure and a simple assembly is proposed and investigated. A tailored horn with a tilted-slot structure was employed in the designed SDUEVC device. Also, the elliptical trajectory formation mechanism of the designed SDUEVC device was described by using the theory of mechanical vibration. Furthermore, the finite element method (FEM) was used to optimize the tilted-slot structure parameters and there are four parameters selected as the optimization factors. The results indicated that the proposed SDUEVC device can generate larger vertical amplitude than previous SDUEVC devices, which provides an important and positive effect for the cutting performance of the proposed SDUEVC device. According to the optimized results, a prototype SDUEVC device was fabricated and its vibration characteristic was tested. When the excitation signal voltage was 500 Vp-p, the test results indicated that the amplitudes in the axial and vertical directions were 8.7 µm and 6.8 µm, respectively. Furthermore, an elliptical trajectory was generated at the cutting tool tip. Finally, the proposed SDUEVC device was used to fabricate microdimple patterns as the initial application to confirm the feasibility of the proposed SDUEVC device.

6.
Beilstein J Nanotechnol ; 8: 2324-2338, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29181289

RESUMO

Surface texturing is an important approach for controlling the tribological behavior of friction pairs used in mechanical and biological engineering. In this study, by utilizing the method of three-dimensional computational fluid dynamics (CFD) simulation, the lubrication model of a friction pair with micro-dimple array was established based on the Navier-Stokes equations. The typical pressure distribution of the lubricant film was analyzed. It was found that a positive hydrodynamic pressure is generated in the convergent part of the micro-dimple, while a negative hydrodynamic pressure is generated in the divergent part. With suitable parameters, the total integration of the pressure is positive, which can increase the load-carrying capacity of a friction pair. The effects of the micro-dimple parameters as well as fluid properties on tribological performance were investigated. It was concluded that under the condition of hydrodynamic lubrication, the main mechanism for the improvement in the tribological performance is the combined effects of wedging and recirculation. Within the range of parameters investigated in this study, the optimum texture density is 13%, while the optimum aspect ratio varies with the Reynolds number. For a given Reynolds number, there exists a combination of texture density and aspect ratio at which the optimum tribological performance could be obtained. Conclusions from this study could be helpful for the design of texture parameters in mechanical friction components and even in artificial joints.

7.
J Mech Behav Biomed Mater ; 72: 192-199, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28500998

RESUMO

Coefficient of friction (COF) tests were conducted on 28-mm and 36-mm-diameter hip joint prostheses for four different material combinations, with or without the presence of Ultra High Molecular Weight Polyethylene (UHMWPE) particles using a novel pendulum hip simulator. The effects of three micro dimpled arrays on femoral head against a polyethylene and a metallic cup were also investigated. Clearance played a vital role in the COF of ceramic on polyethylene and ceramic on ceramic artificial hip joints. Micro dimpled metallic femoral heads yielded higher COF against a polyethylene cup; however, with metal on metal prostheses the dimpled arrays significantly reduced the COF. In situ images revealed evidence that the dimple arrays enhanced film formation, which was the main mechanism that contributed to reduced friction.


Assuntos
Cerâmica/análise , Fricção , Prótese de Quadril , Teste de Materiais , Polietilenos/análise , Interface Osso-Implante , Articulação do Quadril , Humanos , Próteses Articulares Metal-Metal
8.
J Biomed Mater Res B Appl Biomater ; 103(5): 1002-12, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25220737

RESUMO

Diamond like carbon (DLC) is applied as a thin film onto substrates to obtain desired surface properties such as increased hardness and corrosion resistance, and decreased friction and wear rate. Microdimple is an advanced surface modification technique enhancing the tribological performance. In this study, DLC coated microdimples were fabricated on hip prosthesis heads and their mechanical, material and surface properties were characterized. An Electro discharge machining (EDM) oriented microdrilling was utilized to fabricate a defined microdimple array (diameter of 300 µm, depth of 70 µm, and pitch of 900 µm) on stainless steel (SS) hip prosthesis heads. The dimpled surfaces were then coated by hydrogenated amorphous carbon (a-C:H) and tetrahedral amorphous carbon (Ta-C) layers by using a magnetron sputtering technology. A preliminary tribology test was conducted on these fabricated surfaces against a ceramic ball in simulated hip joint conditions. It was found that the fabricated dimples were perpendicular to the spherical surfaces and no cutting-tools wear debris was detected inside the individual dimples. The a-C:H and Ta-C coatings increased the hardness at both the dimple edges and the nondimpled region. The tribology test showed a significant reduction in friction coefficient for coated surfaces regardless of microdimple arrays: the lowest friction coefficient was found for the a-C:H samples (µ = 0.084), followed by Ta-C (µ = 0.119), as compared to the SS surface (µ = 0.248).


Assuntos
Carbono/química , Materiais Revestidos Biocompatíveis/química , Prótese de Quadril , Humanos , Propriedades de Superfície
9.
J Mech Behav Biomed Mater ; 45: 121-31, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25704181

RESUMO

This study investigates a tribological performance of diamond like carbon (DLC) coated micro dimpled prosthesis heads against ceramic cups in a novel pendulum hip joint simulator. The simulator enables determining friction coefficient and viscous effects of a concave shaped specimen interface (conformal contact). Two types of DLC such as hydrogenated amorphous carbon (a-C:H) and tetrahedral amorphous carbon (Ta-C) and one set of micro dimple (diameter of 300µm, depth of 70µm, and pitch of 900µm) were fabricated on metallic prosthesis heads. The experiment results reveal a significant friction coefficient reduction to the 'dimpled a-C:H/ceramic' prosthesis compared to a 'Metal (CoCr)/ceramic' prosthesis because of their improved material and surface properties and viscous effect. The post-experiment surface analysis displays that the dimpled a-C:H yielded a minor change in the surface roughness, and generated a larger sizes of wear debris (40-200nm sized, equivalent diameter), a size which could be certainly stored in the dimple, thus likely to reducing their possible third body abrasive wear rate. Thus, dimpled a:C-H can be used as a 'metal on ceramic hip joint interface', whereas the simulator can be utilized as an advanced bio-tribometer.


Assuntos
Diamante , Teste de Materiais , Fenômenos Mecânicos , Ortopedia , Próteses e Implantes , Fricção , Articulação do Quadril , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa