Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
World J Urol ; 41(11): 3325-3331, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37712968

RESUMO

PURPOSE: To develop and validate a micro-ultrasound risk score that predicts the likelihood of significant prostate cancer in the anterior zone. METHODS: Patients were enrolled from three expert institutions familiar with micro-ultrasound. The study was conducted in two phases. First, the PRI-MUS anterior score was developed by assessing selected prostate videos from patients who subsequently underwent radical prostatectomy. Second, seven urology readers with varying levels of experience in micro-ultrasound examination evaluated prostate loops according to the PRI-MUS anterior score. Each reader watched the videos and recorded the likelihood of the presence of significant cancer in the anterior part of the prostate in a three-point scale. The coherence among the readers was calculated using the Fleiss kappa and the Cronbach alpha. RESULTS: A total of 102 selected prostate scans were used to develop the risk assessment for anterior zone cancer in the prostate. The score comprised three categories: likely, equivocal, and unlikely. The median (IQR) sensitivity, specificity, positive predictive value, and negative predictive value for the seven readers were 72% (68-84), 68% (64-84), 75% (72-81), and 73% (71-80), respectively. The mean SD ROC AUC was 0.75 ± 2%, while the Fleiss kappa and the Cronbach alpha were 0.179 and 0.56, respectively. CONCLUSION: Micro-ultrasound can detect cancerous lesions in the anterior part of the prostate. When combined with the PRI-MUS protocol to assess the peripheral part, it enables an assessment of the entire prostate gland. Pending external validation, the PRI-MUS anterior score developed in this study might be implemented in clinical practice.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/patologia , Ultrassonografia/métodos , Pelve , Medição de Risco , Imageamento por Ressonância Magnética
2.
World J Urol ; 41(11): 3267-3276, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37555985

RESUMO

PURPOSE: Micro-UltraSound (microUS) is a new imaging modality capable of identifying and targeting suspicious areas, which might further increase the diagnostic yield of prostate biopsy (PBx). Aim of this review is to provide insights into the usefulness of microUS for the sub-stratification of prostate cancer (PCa), clinically significant PCa (i.e., any Gleason score ≥ 7 PCa; csPCa) along with non-organ-confined disease in patients undergoing PBx. METHODS: A PubMed literature search was performed using keywords: prostate cancer diagnosis, prostate cancer diagnosis surveillance, systematic biopsy, target biopsy, micro-ultrasound, and prostate risk identification using micro-ultrasound. RESULTS: MicroUS could significantly improve multiparametric magnetic resonance imaging (mpMRI) findings by adding valuable anatomical and pathological information provided by real-time examination. Furthermore, microUS target biopsy could replace systematic biopsy in clinical practice by reducing the detection of clinically insignificant (ciPCa) and increasing that of csPCa. Finally, microUS may be useful in predicting the presence of non-organ confined PCa before radical prostatectomy and it could also be an effective add-on tool for patient monitoring within the active surveillance program. CONCLUSION: MicroUS may represent an attractive step forward for the management of csPCa as a complementary or alternative tool to mpMRI. Nevertheless, further longitudinal studies are warranted, and the strength of the evidence is still suboptimal to provide clear recommendations for daily clinical practice.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Masculino , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/patologia , Biópsia , Antígeno Prostático Específico , Próstata/diagnóstico por imagem , Próstata/patologia , Biópsia Guiada por Imagem/métodos
3.
World J Urol ; 41(3): 641-651, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35835886

RESUMO

PURPOSE: The diagnosis of prostate cancer (PCa) still relies on the performance of both targeted (TB) and systematic biopsies (SB). Micro-ultrasound (mUS)-guided biopsies demonstrated a high sensitivity in detecting clinically significant prostate cancer (csPCa), which could be comparable to that of magnetic resonance imaging (MRI)-TB, but their added value has not been compared to SB yet. METHODS: We conducted a systematic review and meta-analysis, based on Medline, EMBASE, Scopus, and Web of Science, in accordance with PRISMA guidelines, to compare mUS-guided biopsies to SB. RESULTS: Based on the literature search of 2957 articles, 15 met the inclusion criteria (2967 patients). Most patients underwent mUS-guided biopsies, followed by MRI-TB and SB. Respectively 5 (n = 670) and 4 (n = 467) studies, providing raw data on SB, were included in a random-effect meta-analysis of the detection rate of csPCa, i.e. Gleason Grade Group (GGG) ≥ 2 or non-csPCa (GGG = 1). Overall, PCa was detected in 56-71% of men, with 31.3-49% having csPCa and 17-25.4% having non-csPCa. Regarding csPCa, mUS-guided biopsies identified 196 and SB 169 cases (Detection Ratio (DR): 1.18, 95% CI 0.83-1.68, I2 = 69%), favoring mUS-guided biopsies; regarding non-csPCa, mUS-guided biopsies identified 62 and SB 115 cases (DR: 0.55, 95% CI 0.41-0.73, I2 = 0%), also favoring mUS-guided biopsies by decreasing unnecessary diagnosis. CONCLUSION: Micro-ultrasound-guided biopsies compared favorably with SB for the detection of csPCa and detected fewer non-csPCa than SB. Prospective trials are awaited to confirm the interest of adding mUS-guided biopsies to MRI-TB to optimize csPCa detection without increasing overdiagnosis of non-csPCa.


Assuntos
Neoplasias da Próstata , Masculino , Animais , Camundongos , Humanos , Estudos Prospectivos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Biópsia Guiada por Imagem/métodos , Ultrassonografia , Ultrassonografia de Intervenção
4.
World J Urol ; 40(2): 435-442, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35001161

RESUMO

PURPOSE: We aim to evaluate the accuracy of micro-ultrasound (microUS) in predicting extraprostatic extension (EPE) of Prostate Cancer (PCa) prior to surgery. METHODS: Patients with biopsy-proven PCa scheduled for robot-assisted radical prostatectomy (RARP) were prospectively recruited. The following MRI-derived microUS features were evaluated: capsular bulging, visible breach of the prostate capsule (visible extracapsular extension; ECE), presence of hypoechoic halo, and obliteration of the vesicle-prostatic angle. The ability of each feature to predict EPE was determined. RESULTS: Overall, data from 140 patients were examined. All predictors were associated with non-organ-confined disease (p < 0.001). Final pathology showed that 79 patients (56.4%) had a pT2 disease and 61 (43.3%) ≥ pT3. Rate of non-organ-confined disease increased from 44% in those individuals with only 1 predictor (OR 7.71) to 92.3% in those where 4 predictors (OR 72.00) were simultaneously observed. The multivariate logistic regression model including clinical parameters showed an area under the curve (AUC) of 82.3% as compared to an AUC of 87.6% for the model including both clinical and microUS parameters. Presence of ECE at microUS predicted EPE with a sensitivity of 72.1% and a specificity of 88%, a negative predictive value of 80.5% and positive predictive value of 83.0%, with an AUC of 80.4%. CONCLUSIONS: MicroUS can accurately predict EPE at the final pathology report in patients scheduled for RARP.


Assuntos
Prostatectomia , Neoplasias da Próstata , Biópsia , Humanos , Imageamento por Ressonância Magnética , Masculino , Estadiamento de Neoplasias , Estudos Prospectivos , Próstata/diagnóstico por imagem , Próstata/patologia , Próstata/cirurgia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos
5.
World J Urol ; 40(1): 51-59, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34146124

RESUMO

PURPOSE: To discuss the potential utility of newer imaging modalities including micro-ultrasound and PSMA-PET for the detection of clinically significant prostate cancer, technologies that may gain roles as adjuncts to multiparametric magnetic resonance imaging (mpMRI) in the active surveillance (AS) setting. METHODS: Narrative review of two new imaging modalities used for primary prostate cancer through April 2021. A targeted search was performed to identify current relevant literature on the role of new imaging modalities for primary prostate cancer using search terms "micro-ultrasound," "molecular imaging," "prostate cancer," "active surveillance," "multiparametric MRI," "PI-RADS," "PRI-MUS," and "detection rate." In addition, references of included articles were screened for further relevant publications. RESULTS: Micro-ultrasound (micro-US) and prostate-specific membrane antigen-positron emission tomography (PSMA-PET) are increasing in their use and applicability to prostate cancer imaging. Micro-US is used for cancer detection and may identify higher grade cancers more accurately than conventional ultrasound, despite technical hurdles in its initial launch. PSMA-PET is highly sensitive and specific for high-grade and metastatic prostate cancer, though costly and not easily available. Though data are sparse, it may have an emerging role in cancer diagnosis in select localized cases, and in some men considering (or currently on) AS who have indications of more aggressive disease. CONCLUSION: There are very limited data on micro-US and PSMA-PET in AS patients. However, given the ability of these modalities to identify high-grade cancer, their judicious use in AS patients may be of utility in the future.


Assuntos
Neoplasias da Próstata/diagnóstico por imagem , Conduta Expectante , Humanos , Masculino , Neoplasias da Próstata/terapia
6.
Medicina (Kaunas) ; 58(11)2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36363581

RESUMO

Background and Objectives: Multiparametric magnetic resonance imaging (mpMRI) of the prostate and prostate-specific membrane antigen positron emission tomography (PSMA PET) are some examples of how the advancement of imaging techniques have revolutionized the diagnosis, staging, and consequently management of patients with prostate cancer (PCa). Although with less striking results, novel radiological modalities have also been proposed for bladder cancer (BCa) in recent years. Micro-ultrasound (MUS) is an imaging examination characterized by high real-time spatial resolution, recently introduced in the urological field. This article aimed to describe the current evidence regarding the application of MUS for the diagnosis and staging of PCa and BCa. Materials and Methods: We designed a narrative review. A comprehensive search in the MEDLINE, Scopus, and Cochrane Library databases was performed. Articles in English-language and published until July 2022 were deemed eligible. Retrospective and prospective primary clinical studies, as well as meta-analyses, were included. Results: MUS-guided prostate biopsy showed high sensitivity (0.91, 95% CI, 0.79-0.97) in the diagnosis of clinically significant PCa (csPCa). It was associated with a higher detection rate of csPCa than a systematic biopsy (1.18, 95% CI 0.83-1.68). No significant difference was found between MUS and mpMRI-guided biopsy in the total detection of PCa (p = 0.89) and in the detection of Grade Groups ≥ 2 (p = 0.92). The use of MUS to distinguish between non-muscle-invasive and muscle-invasive BCa was described, highlighting an up-staging with MUS only in a minority of cases (28.6%). Conclusions: Promising findings have emerged regarding the feasibility and accuracy of MUS in the diagnosis and staging of PCa and BCa. However, the available evidence is limited and should be considered preliminary.


Assuntos
Neoplasias da Próstata , Neoplasias da Bexiga Urinária , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética
7.
World J Urol ; 39(3): 661-676, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32306060

RESUMO

The diagnosis of prostate cancer (PCa) can be challenging due to the limited performance of current diagnostic tests, including PSA, digital rectal examination and transrectal conventional US. Multiparametric MRI has improved PCa diagnosis and is recommended prior to biopsy; however, mp-MRI does miss a substantial number of PCa. Advanced US modalities include transrectal prostate elastography and contrast-enhanced US, as well as improved B-mode, micro-US and micro-Doppler techniques. These techniques can be combined to define a novel US approach, multiparametric US (mp-US). Mp-US improves PCa diagnosis but is not sufficiently accurate to obviate the utility of mp-MRI. Mp-US using advanced techniques and mp-MRI provide complementary information which will become even more important in the era of focal therapy, where precise identification of PCa location is needed.


Assuntos
Neoplasias da Próstata/diagnóstico por imagem , Adulto , Idoso , Meios de Contraste , Técnicas de Imagem por Elasticidade , Humanos , Masculino , Ultrassonografia/métodos
8.
World J Urol ; 38(5): 1201-1206, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31309290

RESUMO

PURPOSE: This report presents our early experience at Cleveland Clinic replacing conventional ultrasound with a novel 29 MHz high-resolution micro-ultrasound system for both systematic sampling and real-time targeting of suspicious regions during prostate biopsy. The added value of micro-ultrasound and MRI over systematic biopsy is presented. METHODS: Sixty-seven consecutive subjects (January-August 2018) from our prospective database who underwent prostate biopsy using the micro-ultrasound system were included. 19/67 had prostate MRI imaging available. MRI targets were sampled using the UroNav fusion system. Patients had a median PSA of 5.37 ng/mL (IQR 4.13-8.74). RESULTS: 38/67 (56.7%) subjects were positive for prostate cancer. In six of these cases, systematic biopsy was negative with only micro-ultrasound targeted samples detecting cancer. In two other cases, patients were upgraded from Grade Group 1 to Grade Groups 4 and 2 based on micro-ultrasound targets. Micro-ultrasound targets detected cancer in two subjects where MRI was negative (Grade Groups 3 and 2). MRI targets alone did not change the overall diagnosis of any subjects. Switching biopsy guidance to real-time micro-ultrasound increased detection rate on prostate biopsy from 44.8% (30/67) to 56.7% (38/67), a relative increase of 26.7%. CONCLUSION: High-resolution micro-ultrasound identified clinically significant cancer that would have, otherwise, been missed by both MRI fusion and systematic biopsy and was useful in both biopsy naïve and repeat negative patients. Early results from this small, single-center cohort are promising, particularly given the ease with which micro-ultrasound can replace the conventional ultrasound in standard prostate biopsy procedures.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Próstata/patologia , Neoplasias da Próstata/patologia , Ultrassonografia de Intervenção , Idoso , Estudos de Coortes , Humanos , Biópsia Guiada por Imagem/métodos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Reto , Ultrassonografia de Intervenção/métodos
10.
Biochem Biophys Res Commun ; 464(3): 737-42, 2015 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-26187672

RESUMO

Air-filled polyvinyl alcohol microbubbles (PVA-MBs) were recently introduced as a contrast agent for ultrasound imaging. In the present study, we explore the possibility of extending their application in multimodal imaging by labeling them with a near infrared (NIR) fluorophore, VivoTag-680. PVA-MBs were injected intravenously into FVB/N female mice and their dynamic biodistribution over 24 h was determined by 3D-fluorescence imaging co-registered with 3D-µCT imaging, to verify the anatomic location. To further confirm the biodistribution results from in vivo imaging, organs were removed and examined histologically using bright field and fluorescence microscopy. Fluorescence imaging detected PVA-MB accumulation in the lungs within the first 30 min post-injection. Redistribution to a low extent was observed in liver and kidneys at 4 h, and to a high extent mainly in the liver and spleen at 24 h. Histology confirmed PVA-MB localization in lung capillaries and macrophages. In the liver, they were associated with Kupffer cells; in the spleen, they were located mostly within the marginal-zone. Occasional MBs were observed in the kidney glomeruli and interstitium. The potential application of PVA-MBs as a contrast agent was also studied using ultrasound (US) imaging in subcutaneous and orthotopic pancreatic cancer mouse models, to visualize blood flow within the tumor mass. In conclusion, this study showed that PVA-MBs are useful as a contrast agent for multimodal imaging.


Assuntos
Meios de Contraste , Corantes Fluorescentes , Microbolhas , Imagem Multimodal/métodos , Animais , Linhagem Celular Tumoral , Feminino , Xenoenxertos , Humanos , Imageamento Tridimensional , Camundongos , Camundongos Endogâmicos C57BL , Imagem Óptica , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/diagnóstico por imagem , Ultrassonografia , Microtomografia por Raio-X
11.
J Cereb Blood Flow Metab ; 44(4): 461-476, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37974304

RESUMO

Notwithstanding recanalization treatments in the acute stage of stroke, many survivors suffer long-term impairments. Physical rehabilitation is the only widely available strategy for chronic-stage recovery, but its optimization is hindered by limited understanding of its effects on brain structure and function. Using micro-ultrasound, behavioral testing, and electrophysiology, we investigated the impact of skilled reaching rehabilitation on cerebral hemodynamics, motor function, and neuronal activity in a rat model of focal ischemic stroke. A 50 MHz micro-ultrasound transducer and intracortical electrophysiology were utilized to characterize neurovascular changes three weeks following focal ischemia elicited by endothelin-1 injection into the sensorimotor cortex. Sprague-Dawley rats were rehabilitated through tray reaching, and their fine skilled reaching was assessed via the Montoya staircase. Focal ischemia led to a sustained deficit in forelimb reaching; and increased tortuosity of the penetrating vessels in the perilesional cortex; with no lateralization of spontaneous neuronal activity. Rehabilitation improved skilled reaching; decreased cortical vascularity; was associated with elevated peri- vs. contralesional hypercapnia-induced flow homogenization and increased perilesional spontaneous cortical neuronal activity. Our study demonstrated neurovascular plasticity accompanying rehabilitation-elicited functional recovery in the subacute stage following stroke, and multiple micro-ultrasound-based markers of cerebrovascular structure and function modified in recovery from ischemia and upon rehabilitation.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Córtex Sensório-Motor , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Ratos , Animais , Humanos , Ratos Sprague-Dawley , Recuperação de Função Fisiológica/fisiologia , Isquemia , Membro Anterior , Modelos Animais de Doenças , Plasticidade Neuronal
12.
Comput Med Imaging Graph ; 112: 102326, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38211358

RESUMO

Micro-ultrasound (micro-US) is a novel 29-MHz ultrasound technique that provides 3-4 times higher resolution than traditional ultrasound, potentially enabling low-cost, accurate diagnosis of prostate cancer. Accurate prostate segmentation is crucial for prostate volume measurement, cancer diagnosis, prostate biopsy, and treatment planning. However, prostate segmentation on micro-US is challenging due to artifacts and indistinct borders between the prostate, bladder, and urethra in the midline. This paper presents MicroSegNet, a multi-scale annotation-guided transformer UNet model designed specifically to tackle these challenges. During the training process, MicroSegNet focuses more on regions that are hard to segment (hard regions), characterized by discrepancies between expert and non-expert annotations. We achieve this by proposing an annotation-guided binary cross entropy (AG-BCE) loss that assigns a larger weight to prediction errors in hard regions and a lower weight to prediction errors in easy regions. The AG-BCE loss was seamlessly integrated into the training process through the utilization of multi-scale deep supervision, enabling MicroSegNet to capture global contextual dependencies and local information at various scales. We trained our model using micro-US images from 55 patients, followed by evaluation on 20 patients. Our MicroSegNet model achieved a Dice coefficient of 0.939 and a Hausdorff distance of 2.02 mm, outperforming several state-of-the-art segmentation methods, as well as three human annotators with different experience levels. Our code is publicly available at https://github.com/mirthAI/MicroSegNet and our dataset is publicly available at https://zenodo.org/records/10475293.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Ultrassonografia/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Bexiga Urinária , Processamento de Imagem Assistida por Computador/métodos
13.
Clin Hemorheol Microcirc ; 87(1): 89-100, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38160349

RESUMO

 Recently diagnostic field in medicine was enriched by advances in ultrasonography (US) technology, which led to establishment of novel modalities, one of which is micro-ultrasound. Results demonstrated by early studies have been promising, simultaneously rising a question if those new modalities could become an alternative in diagnosis of prostatic carcinoma (PCa). To answer this question, several studies have been conducted where micro-ultrasound have been compared to standard diagnostic tools, such as conventional TRUS or mpMRI. Nevertheless, new technology presents with some limitations, which include inconsistent results, necessity for specialized equipment, need of training for investigators to understand the findings, and external validation. In this publication, we have identified studies that provided evaluation of the accuracy and efficiency of the micro-ultrasound technology. Additionally, analysis of the results provided a better understanding of the novel imaging tool when compared standard modalities in diagnosis of PCa. Increasing number of studies demonstrated that micro-ultrasound carries high detection rate of PCa and clinically significant prostatic cancer (csPCa), suggesting a similar performance to mpMRI and even showing superiority over conventional TRUS. Recent studies have also showed that micro-ultrasound takes active role in improving the detection of csPCa and guidance for prostate biopsy (PBx) as well as further treatment. Moreover, certain practical aspects such as lower costs, decreased waiting time, real-time imaging and application of the imaging tool for patients that are not suitable for mpMRI (contrast allergy, prosthetics etc.) are significant advantages. Analysis of the results still does not provide clear answer whether micro-ultrasound outperforms mpMRI. Further studies are necessary in order to completely understand the potential of this new technology.


Assuntos
Neoplasias da Próstata , Ultrassonografia , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Ultrassonografia/métodos
14.
Eur Urol Open Sci ; 66: 93-100, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39076245

RESUMO

Background and objective: Micro-ultrasound (MUS) uses a high-frequency transducer with superior resolution to conventional ultrasound, which may differentiate prostate cancer from normal tissue and thereby allow targeted biopsy. Preliminary evidence has shown comparable sensitivity to magnetic resonance imaging (MRI), but consistency between users has yet to be described. Our objective was to assess agreement of MUS interpretation across multiple readers. Methods: After institutional review board approval, we prospectively collected MUS images for 57 patients referred for prostate biopsy after multiparametric MRI from 2022 to 2023. MUS images were interpreted by six urologists at four institutions with varying experience (range 2-6 yr). Readers were blinded to MRI results and clinical data. The primary outcome was reader agreement on the locations of suspicious lesions, measured in terms of Light's κ and positive percent agreement (PPA). Reader sensitivity for identification of grade group (GG) ≥2 prostate cancer was a secondary outcome. Key findings and limitations: Analysis revealed a κ value of 0.30 (95% confidence interval [CI] 0.21-0.39). PPA was 33% (95% CI 25-42%). The mean patient-level sensitivity for GG ≥2 cancer was 0.66 ± 0.05 overall and 0.87 ± 0.09 when cases with anterior lesions were excluded. Readers were 12 times more likely to detect higher-grade cancers (GG ≥3), with higher levels of agreement for this subgroup (κ 0.41, PPA 45%). Key limitations include the inability to prospectively biopsy reader-delineated targets and the inability of readers to perform live transducer maneuvers. Conclusions and clinical implications: Inter-reader agreement on the location of suspicious lesions on MUS is lower than rates previously reported for MRI. MUS sensitivity for cancer in the anterior gland is lacking. Patient summary: The ability to find cancer on imaging scans can vary between doctors. We found that there was frequent disagreement on the location of prostate cancer when doctors were using a new high-resolution scan method called micro-ultrasound. This suggests that the performance of micro-ultrasound is not yet consistent enough to replace MRI (magnetic resonance imaging) for diagnosis of prostate cancer.

15.
Diagnostics (Basel) ; 14(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38472997

RESUMO

BACKGROUND: The diagnostic process for prostate cancer after a negative biopsy is challenging. This study compares the diagnostic accuracy of micro-ultrasound (mUS) with multiparametric magnetic resonance imaging (mpMRI) for such cases. METHODS: A retrospective cohort study was performed, targeting men with previous negative biopsies and using mUS and mpMRI to detect prostate cancer and clinically significant prostate cancer (csPCa). RESULTS: In our cohort of 1397 men, 304 had a history of negative biopsies. mUS was more sensitive than mpMRI, with better predictive value for negative results. Importantly, mUS was significantly associated with csPCa detection (adjusted odds ratio [aOR]: 6.58; 95% confidence interval [CI]: 1.15-37.8; p = 0.035). CONCLUSIONS: mUS may be preferable for diagnosing prostate cancer in previously biopsy-negative patients. However, the retrospective design of this study at a single institution suggests that further research across multiple centers is warranted.

16.
Sci Rep ; 14(1): 18910, 2024 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-39143293

RESUMO

Micro-ultrasound has recently been introduced as a low-cost alternative to multi-parametric MRI for imaging prostate cancer. Early clinical studies have demonstrated promising results; however, robust validation via comparison with whole-mount pathology has yet to be achieved. Due to micro-ultrasound probe design and tissue deformation during scanning, it is difficult to accurately correlate micro-ultrasound imaging planes with ground truth whole-mount pathology slides. In this study, we developed a multi-step methodology to co-register micro-ultrasound and MRI to whole-mount pathology. The three-step process had a registration error of 3.90 ± 0.11 mm and consists of: (1) micro-ultrasound image reconstruction, (2) 3D landmark registration of micro-ultrasound to MRI, and (3) 2D capsule registration of MRI to whole-mount pathology. This process was then used in a preliminary reader study to compare the diagnostic accuracy of micro-ultrasound and MRI in 15 patients who underwent radical prostatectomy for prostate cancer. Micro-ultrasound was found to have equivalent performance to retrospective MRI review for index lesion detection (91.7% vs. 80%), while demonstrating an increased detection of tumor extent (52.5% vs. 36.7%) with similar false positive regions-of-interest (38.3% vs. 40.8%). Prospective MRI review had reduced detection of index lesions (73.3%) and tumor extent (18.9%) but improved false positive regions-of-interest (22.7%) relative to micro-ultrasound and retrospective MRI. Further evaluation is needed with a larger sample size.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Ultrassonografia , Humanos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Masculino , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Próstata/patologia , Prostatectomia , Processamento de Imagem Assistida por Computador/métodos
17.
Eur Urol Open Sci ; 69: 7-12, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39314912

RESUMO

Background and objective: High-resolution micro-ultrasound (microUS) is an advanced imaging tool. Our objective was to determine whether systematic microUS use for transrectal biopsy (TRBx) improves the detection rate for clinically significant prostate cancer (csPCa) in comparison to transperineal biopsy (TPBx) performed with magnetic resonance imaging (MRI)/conventional transrectal ultrasound (TRUS) fusion software. Methods: We retrospectively analyzed data for men who underwent prostate biopsies, including those on active surveillance (AS). TRBx was performed under microUS guidance, while MRI/TRUS fusion was consistently used to guide TPBx. Patients were matched according to propensity score matching (PSM). The primary endpoint was comparison of the csPCa detection rate with the two approaches. Secondary endpoints included predictors of csPCa (International Society of Urological Pathology grade group ≥2, assessed via multivariable logistic regression) and complication rates. Key findings and limitations: Overall, 1423 patients were enrolled. After applying PSM we identified an analytical cohort of 1094 men, 582 in the TRBx group and 512 in the TPBx group. There was no significant difference in the csPCa detection rate between the TRBx (45%) and TPBx (51%) groups (p = 0.07). Complications occurred in nine of 1094 patients (1%). On adjusted multivariable analysis, TPBx had a similar csPCa detection rate to TRBx (adjusted odds ratio [aOR] 1.26;p = 0.09). Predictors of csPCa detection were a positive family history (aOR 1.68; 95% confidence interval [CI] 1.20-2.35; p = 0.002); age (aOR 1.04, 95% CI 1.02-1.06; p < 0.001); positive digital rectal examination (aOR 2.35, 95% CI 1.70-3.25; p < 0.001); prostate-specific antigen density ≥0.15 ng/ml/cm3 (aOR 3.23, 95% CI 2.47-4.23; p < 0.001); and a Prostate Imaging-Reporting and Data System score ≥3 (aOR 2.46; 95% CI 1.83-3.32; p < 0.001). Limitations include the retrospective nature of the study, the risk of underestimating the complication rate, and the heterogeneity of biopsy indications. Conclusions and clinical implications: TRBx using microUS alone showed a comparable csPCa detection rate to TPBx guided by MRI/TRUS fusion software. Given the better visualization and real-time detection of suspicious zones with microUS, the potential for improvement in the csPCa detection rate with greater integration of microUS in the TPBx setting warrants further investigation. Patient summary: We compared the ability of two different prostate biopsy approaches to detect clinically significant prostate cancer. We found that transrectal biopsy guided by micro-ultrasound had similar detection rates to transperineal biopsy guided by a combination of magnetic resonance imaging and conventional ultrasound. More research is needed to confirm the potential of micro-ultrasound for transperineal biopsy.

18.
Ultrasound Med Biol ; 50(4): 457-466, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38238200

RESUMO

OBJECTIVE: High-frequency, high-resolution transrectal micro-ultrasound (micro-US: ≥15 MHz) imaging of the prostate is emerging as a beneficial tool for scoring disease risk and accurately targeting biopsies. Adding photoacoustic (PA) imaging to visualize abnormal vascularization and accumulation of contrast agents in tumors has potential for guiding focal therapies. In this work, we describe a new imaging platform that combines a transrectal micro-US system with transurethral light delivery for PA imaging. METHODS: A clinical transrectal micro-US system was adapted to acquire PA images synchronous to a tunable laser pulse. A transurethral side-firing optical fiber was developed for light delivery. A polyvinyl chloride (PVC)-plastisol phantom was developed and characterized to image PA contrast agents in wall-less channels. After resolution measurement in water, PA imaging was demonstrated in phantom channels with dyes and biodegradable nanoparticle contrast agents called porphysomes. In vivo imaging of a tumor model was performed, with porphysomes administered intravenously. RESULTS: Photoacoustic imaging data were acquired at 5 Hz, and image reconstruction was performed offline. PA image resolution at a 14-mm depth was 74 and 261 µm in the axial and lateral directions, respectively. The speed of sound in PVC-plastisol was 1383 m/s, and the attenuation was 4 dB/mm at 20 MHz. PA signal from porphysomes was spectrally unmixed from blood signals in the tumor, and a signal increase was observed 3 h after porphysome injection. CONCLUSION: A combined transrectal micro-US and PA imaging system was developed and characterized, and in vivo imaging demonstrated. High-resolution PA imaging may provide valuable additional information for diagnostic and therapeutic applications in the prostate.


Assuntos
Neoplasias , Técnicas Fotoacústicas , Masculino , Humanos , Próstata/diagnóstico por imagem , Meios de Contraste , Ultrassonografia/métodos , Imagens de Fantasmas , Técnicas Fotoacústicas/métodos
19.
Cancers (Basel) ; 15(4)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36831622

RESUMO

Prostate Cancer (PCa) is the second most common cancer in men. Population screening using prostate specific antigen (PSA) blood test and digital rectal exam (DRE) is recommended by the NCCN, EAU and other prominent clinical guidelines. While MRI is the recommended initial test in men at risk for PCa, micro-Ultrasound (MicroUS) is a novel high resolution ultrasound technology that has shown promise in PCa detection. This article provides a narrative review of the studies to date which have been conducted to evaluate the functionality and efficacy of MicroUS within the patient care pathway for prostate cancer. A total of 13 relevant publications comparing detection of csPCa between MicroUS and mpMRI were selected. An amount of 4 publications referring to use of MicroUS for other indications were found. Each publication was evaluated for risk of bias and applicability using the Quality Assessment of Diagnostic Accuracy (QUADAS-2) tool. The studies reviewed conclude that MicroUS detection rates for clinically significant prostate cancer diagnosis are comparable to the detection rates of mpMRI guided biopsy procedures. While the existing literature indicates that MicroUS should replace conventional TRUS for prostate imaging and biopsy, it is not yet clear whether MicroUS should be used on its own or in conjunction with mpMRI for augmenting prostate cancer detection. The ongoing OPTIMUM trial will provide evidence on how best to utilize this new technology. Early data also suggest this flexible new imaging modality has a place in local staging and active surveillance of prostate cancer as well as in bladder cancer staging.

20.
Int J Comput Assist Radiol Surg ; 18(7): 1193-1200, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37217768

RESUMO

PURPOSE: A large body of previous machine learning methods for ultrasound-based prostate cancer detection classify small regions of interest (ROIs) of ultrasound signals that lie within a larger needle trace corresponding to a prostate tissue biopsy (called biopsy core). These ROI-scale models suffer from weak labeling as histopathology results available for biopsy cores only approximate the distribution of cancer in the ROIs. ROI-scale models do not take advantage of contextual information that are normally considered by pathologists, i.e., they do not consider information about surrounding tissue and larger-scale trends when identifying cancer. We aim to improve cancer detection by taking a multi-scale, i.e., ROI-scale and biopsy core-scale, approach. METHODS: Our multi-scale approach combines (i) an "ROI-scale" model trained using self-supervised learning to extract features from small ROIs and (ii) a "core-scale" transformer model that processes a collection of extracted features from multiple ROIs in the needle trace region to predict the tissue type of the corresponding core. Attention maps, as a by-product, allow us to localize cancer at the ROI scale. RESULTS: We analyze this method using a dataset of micro-ultrasound acquired from 578 patients who underwent prostate biopsy, and compare our model to baseline models and other large-scale studies in the literature. Our model shows consistent and substantial performance improvements compared to ROI-scale-only models. It achieves [Formula: see text] AUROC, a statistically significant improvement over ROI-scale classification. We also compare our method to large studies on prostate cancer detection, using other imaging modalities. CONCLUSIONS: Taking a multi-scale approach that leverages contextual information improves prostate cancer detection compared to ROI-scale-only models. The proposed model achieves a statistically significant improvement in performance and outperforms other large-scale studies in the literature. Our code is publicly available at www.github.com/med-i-lab/TRUSFormer .


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Biópsia Guiada por Imagem/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Ultrassonografia/métodos , Pelve
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa