Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 192
Filtrar
1.
J Obstet Gynaecol Res ; 50(3): 438-447, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38148300

RESUMO

OBJECTIVE: This study aimed to determine the effect of progressive relaxation exercises (PRE) and transcutaneous electrical nerve stimulation administered to women delivering via cesarean delivery on acute pain, breastfeeding success, and comfort levels. METHODS: This is a single-blind, randomized controlled study. This study was carried out in the obstetrics and gynecology clinic of a university hospital affiliated with the Ministry of Health in Turkey between August 20, 2018 and April 15, 2019. A total of 120 participants were randomly assigned to one of four groups, which included a transcutaneous electrical neural stimulation (TENS) group, a PRE group, a combined intervention group, and a control group. Data were collected with a Data Collection Form, The Visual Analogue Scale, The LATCH Breastfeeding Diagnostic Tool, and The Postpartum Comfort Scale. RESULTS: According to the findings of the study, it was determined that pain significantly decreased and comfort increased after having a cesarean delivery in all three intervention groups compared to the control group (p < 0.05). Regarding the breastfeeding success, while there was no statistically significant change in this behavior in the TENS group, it was significantly better in the PRE group and the combined intervention group, where TENS and PRE were administered together (p < 0.05). CONCLUSIONS: According to our study results, we recommend that TENS and PRE should be employed together after a cesarean delivery as safe non-pharmacological methods in pain management, eliminating breastfeeding problems, and increasing comfort.


Assuntos
Estimulação Elétrica Nervosa Transcutânea , Gravidez , Feminino , Humanos , Estimulação Elétrica Nervosa Transcutânea/métodos , Aleitamento Materno , Método Simples-Cego , Treinamento Autógeno , Dor
2.
Neuroimage ; 276: 120185, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37244320

RESUMO

OBJECTIVE: Blood-oxygen-level-dependent functional MRI allows to investigte neural activities and connectivity. While the non-human primate plays an essential role in neuroscience research, multimodal methods combining functional MRI with other neuroimaging and neuromodulation enable us to understand the brain network at multiple scales. APPROACH: In this study, a tight-fitting helmet-shape receive array with a single transmit loop for anesthetized macaque brain MRI at 7T was fabricated with four openings constructed in the coil housing to accommodate multimodal devices, and the coil performance was quantitatively evaluated and compared to a commercial knee coil. In addition, experiments over three macaques with infrared neural stimulation (INS), focused ultrasound stimulation (FUS), and transcranial direct current stimulation (tDCS) were conducted. MAIN RESULTS: The RF coil showed higher transmit efficiency, comparable homogeneity, improved SNR and enlarged signal coverage over the macaque brain. Infrared neural stimulation was applied to the amygdala in deep brain region, and activations in stimulation sites and connected sites were detected, with the connectivity consistent with anatomical information. Focused ultrasound stimulation was applied to the left visual cortex, and activations were acquired along the ultrasound traveling path, with all time course curves consistent with pre-designed paradigms. The existence of transcranial direct current stimulation electrodes brought no interference to the RF system, as evidenced through high-resolution MPRAGE structure images. SIGNIFICANCE: This pilot study reveals the feasibility for brain investigation at multiple spatiotemporal scales, which may advance our understanding in dynamic brain networks.


Assuntos
Estimulação Transcraniana por Corrente Contínua , Animais , Haplorrinos , Projetos Piloto , Imageamento por Ressonância Magnética , Neuroimagem , Encéfalo/diagnóstico por imagem , Macaca , Desenho de Equipamento , Imagens de Fantasmas , Ondas de Rádio , Razão Sinal-Ruído
3.
J Neurosci Res ; 101(8): 1360-1379, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37186320

RESUMO

Neuroinflammation is a reaction of nervous tissue to an attack caused by an infection, a toxin, or a neurodegenerative disease. It involves brain metabolism adaptation in order to meet the increased energy needs of glial cell activation, but the nature of these adaptations is still unknown. Increasing interest concerning neuroinflammation leads to the identification of its role in neurodegenerative diseases. Few reports studied the effect of metabolic alteration on neuroinflammation. Metabolic damage initiates a pro-inflammatory response by microglial activation. Moreover, the exact neuroinflammation effect on cerebral cell metabolism remains unknown. In this study, we reviewed systematically the neuroinflammation effect in animal models' brains. All articles showing the relationship of neuroinflammation with brain metabolism, or with neuronal stimulation in neurodegenerative diseases were considered. Moreover, this review examines also the mitochondrial damage effect in neurodegeneration diseases. Then, different biosensors are classified regarding their importance in the determination of metabolite change. Finally, some therapeutic drugs inhibiting neuroinflammation are cited. Neuroinflammation increases lymphocyte infiltration and cytokines' overproduction, altering cellular energy homeostasis. This review demonstrates the importance of neuroinflammation as a mediator of disease progression. Further, the spread of depolarization effects pro-inflammatory genes expression and microglial activation, which contribute to the degeneration of neurons, paving the road to better management and treatment of neurodegenerative diseases.


Assuntos
Encefalite , Doenças Neurodegenerativas , Animais , Doenças Neurodegenerativas/metabolismo , Doenças Neuroinflamatórias , Encéfalo/metabolismo , Encefalite/metabolismo , Neurônios/metabolismo , Microglia/metabolismo , Inflamação/metabolismo
4.
Neuromodulation ; 26(8): 1757-1771, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36707292

RESUMO

OBJECTIVES: Small-diameter afferent axons carry various sensory signals that are critical for vital physiological conditions but sometimes contribute to pathologies. Infrared (IR) neural inhibition (INI) can induce selective heat block of small-diameter axons, which holds potential for translational applications such as pain management. Previous research suggested that IR-heating-induced acceleration of voltage-gated potassium channel kinetics is the mechanism for INI. Therefore, we hypothesized that other heating methods, such as resistive heating (RH) in a cuff, could reproduce the selective inhibition observed in INI. MATERIALS AND METHODS: We conducted ex vivo nerve-heating experiments on pleural-abdominal connective nerves of Aplysia californica using both IR and RH. We fabricated a transparent silicone nerve cuff for simultaneous IR heating, RH, and temperature measurements. Temperature elevations (ΔT) on the nerve surface were recorded for both heating modalities, which were tested over a range of power levels that cover a similar ΔT range. We recorded electrically evoked compound action potentials (CAPs) and segmented them into fast and slow subcomponents on the basis of conduction velocity differences between the large and small-diameter axonal subpopulations. We calculated the normalized inhibition strength and inhibition selectivity index on the basis of the rectified area under the curve of each subpopulation. RESULTS: INI and RH showed a similar selective inhibition effect on CAP subcomponents for slow-conducting axons, confirmed by the inhibition probability vs ΔT dose-response curve based on approximately 2000 CAP measurements. The inhibition selectivity indexes of the two heating modalities were similar across six nerves. RH only required half the total electrical power required by INI to achieve a similar ΔT. SIGNIFICANCE: We show that selective INI can be reproduced by other heating modalities such as RH. RH, because of its high energy efficiency and simple design, can be a good candidate for future implantable neural interface designs.


Assuntos
Calefação , Condução Nervosa , Humanos , Condução Nervosa/fisiologia , Inibição Neural , Potenciais de Ação/fisiologia , Axônios/fisiologia
5.
Small ; 18(8): e2105388, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34894073

RESUMO

Neurons can be modified to express light-sensitive proteins for enabling stimulation with a high spatial and temporal resolution, but such techniques require gene transfection and systematical implantation. Here, a black phosphorus nanosheet-based injectable strategy is described for wireless neural stimulation both in vitro and in vivo without cell modifications. These nanosheets, with minimal invasiveness, high biocompatibility, and biodegradability, are anchored on cell membranes as miniature near-infrared (NIR) light transducers to create local heating for neural activity excitation. Based on cultured multielectrode-array recording, in vivo electrophysiology analysis, and open field behavioral tests, it is demonstrated that remotely applied NIR illumination can reliably trigger spiking activity in cultured neurons and rat brains. Excitingly, reliable regulation of brain function to control animal behaviors is also described. Moreover, this approach has shown its potential for future clinical use by successful high-frequency stimulation in cells and animals in this proof-of-concept study. It is believed that this new method will offer a powerful alternative to other neural stimulation solutions and potentially be of independent value to the healthcare system.


Assuntos
Sistemas de Liberação de Medicamentos , Fósforo , Animais , Neurônios , Ratos
6.
J Comput Neurosci ; 50(3): 313-330, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35419717

RESUMO

Efforts on selective neural stimulation have concentrated on segregating axons based on their size and geometry. Nonetheless, axons of the white matter or peripheral nerves may also differ in their electrophysiological properties. The primary objective of this study was to investigate the possibility of selective activation of axons by leveraging an assumed level of diversity in passive (Cm & Gleak) and active membrane properties (Ktemp & Gnamax). First, the stimulus waveforms with hyperpolarizing (HPP) and depolarizing pre-pulsing (DPP) were tested on selectivity in a local membrane model. The default value of membrane capacitance (Cm) was found to play a critical role in sensitivity of the chronaxie time (Chr) and rheobase (Rhe) to variations of all the four membrane parameters. Decreasing the default value of Cm, and thus the passive time constant of the membrane, amplified the sensitivity to the active parameters, Ktemp and GNamax, on Chr. The HPP waveform could selectively activate neurons even if they were diversified by membrane leakage (Gleak) only, and produced higher selectivity than DPP when parameters are varied in pairs. Selectivity measures were larger when the passive parameters (Cm & Gleak) were varied together, compared to the active parameters. Second, this novel mechanism of selectivity was investigated with non-rectangular waveforms for the stimulating phase (and HPP) in the same local membrane model. Simulation results suggest that Kt2 is the most selective waveform followed by Linear and Gaussian waveforms. Traditional rectangular pulse was among the least selective of all. Finally, a compartmental axon model confirmed the main findings of the local model that Kt2 is the most selective, but rank ordered the other waveforms differently. These results suggest a potentially novel mechanism of stimulation selectivity, leveraging electrophysiological variations in membrane properties, that can lead to various neural prosthetic applications.


Assuntos
Fenômenos Eletrofisiológicos , Modelos Neurológicos , Estimulação Elétrica/métodos , Neurônios/fisiologia , Distribuição Normal
7.
IEEE J Solid-State Circuits ; 57(3): 818-830, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36275505

RESUMO

This paper presents a hardware platform including stimulating implants wirelessly powered and controlled by a shared transmitter for coordinated leadless multisite stimulation. The adopted novel single-transmitter, multiple-implant structure can flexibly deploy stimuli, improve system efficiency, easily scale stimulating channel quantity and relieve efforts in device synchronization. In the proposed system, a wireless link leveraging magnetoelectric effects is co-designed with a robust and efficient system-on-chip to enable reliable operation and individual programming of every implant. Each implant integrates a 0.8-mm2 chip, a 6-mm2 magnetoelectric film, and an energy storage capacitor within a 6.2-mm3 size. Magnetoelectric power transfer is capable of safely transmitting milliwatt power to devices placed several centimeters away from the transmitter coil, maintaining good efficiency with size constraints and tolerating 60-degree, 1.5-cm misalignment in angular and lateral movement. The SoC robustly operates with 2-V source amplitude variations that spans a 40-mm transmitter-implant distance change, realizes individual addressability through physical unclonable function IDs, and achieves 90% efficiency for 1.5-to-3.5-V stimulation with fully programmable stimulation parameters.

8.
J Neuroeng Rehabil ; 19(1): 85, 2022 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-35945575

RESUMO

BACKGROUND: Stimulation-driven exercise is often limited by rapid fatigue of the activated muscles. Selective neural stimulation patterns that decrease activated fiber overlap and/or duty cycle improve cycling exercise duration and intensity. However, unequal outputs from independently activated fiber populations may cause large discrepancies in power production and crank angle velocity among pedal revolutions. Enforcing a constant cadence through feedback control of stimulus levels may address this issue and further improve endurance by targeting a submaximal but higher than steady-state exercise intensity. METHODS: Seven participants with paralysis cycled using standard cadence-controlled stimulation (S-Cont). Four of those participants also cycled with a low duty cycle (carousel) cadence-controlled stimulation scheme (C-Cont). S-Cont and C-Cont patterns were compared with conventional maximal stimulation (S-Max). Outcome measures include total work (W), end power (Pend), power fluctuation (PFI), charge accumulation (Q) and efficiency (η). Physiological measurements of muscle oxygenation (SmO2) and heart rate were also collected with select participants. RESULTS: At least one cadence-controlled stimulation pattern (S-Cont or C-Cont) improved Pend over S-Max in all participants and increased W in three participants. Both controlled patterns increased Q and η and reduced PFI compared with S-Max and prior open-loop studies. S-Cont stimulation also delayed declines in SmO2 and increased heart rate in one participant compared with S-Max. CONCLUSIONS: Cadence-controlled selective stimulation improves cycling endurance and increases efficiency over conventional stimulation by incorporating fiber groups only as needed to maintain a desired exercise intensity. Closed-loop carousel stimulation also successfully reduces power fluctuations relative to previous open-loop efforts, which will enable neuroprosthesis recipients to better take advantage of duty cycle reducing patterns.


Assuntos
Ciclismo , Paralisia , Ciclismo/fisiologia , Retroalimentação , Humanos , Músculo Esquelético/fisiologia
9.
Neuroimage ; 231: 117818, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33548458

RESUMO

We have previously shown that INS-fMRI is a rapid method for mapping mesoscale brain networks in the macaque monkey brain. Focal stimulation of single cortical sites led to the activation of connected cortical locations, resulting in a global connectivity map. Here, we have extended this method for mapping brainwide networks following stimulation of single subcortical sites. As a testbed, we focused on the basal nucleus of the amygdala in the macaque monkey. We describe methods to target basal nucleus locations with submillimeter precision, pulse train stimulation methods, and statistical tests for assessing non-random nature of activations. Using these methods, we report that stimulation of precisely targeted loci in the basal nucleus produced sparse and specific activations in the brain. Activations were observed in the insular and sensory association cortices as well as activations in the cingulate cortex, consistent with known anatomical connections. What is new here is that the activations were focal and, in some cases, exhibited shifting topography with millimeter shifts in stimulation site. The precision of the method enables networks mapped from different nearby sites in the basal nucleus to be distinguished. While further investigation is needed to improve the sensitivity of this method, our analyses do support the reproducibility and non-random nature of some of the activations. We suggest that INS-fMRI is a promising method for mapping large-scale cortical and subcortical networks at high spatial resolution.


Assuntos
Complexo Nuclear Basolateral da Amígdala/diagnóstico por imagem , Mapeamento Encefálico/métodos , Córtex Cerebral/diagnóstico por imagem , Raios Infravermelhos , Imageamento por Ressonância Magnética/métodos , Rede Nervosa/diagnóstico por imagem , Animais , Complexo Nuclear Basolateral da Amígdala/fisiologia , Córtex Cerebral/fisiologia , Macaca , Rede Nervosa/fisiologia , Primatas
10.
IEEE J Solid-State Circuits ; 56(7): 2142-2157, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34483356

RESUMO

We present a 180-nm CMOS bidirectional neural interface system-on-chip that enables simultaneous recording and stimulation with on-chip stimulus artifact cancelers. The front-end cancellation scheme incorporates a least-mean-square engine that adapts the coefficients of a 2-tap infinite-impulse-response filter to replicate the stimulation artifact waveform and subtract it at the front-end. Measurements demonstrate the efficacy of the canceler in mitigating artifacts up to 700 mVpp and reducing the front-end amplifier saturation recovery time in response to a 2.5 Vpp artifact. Each recording channel houses a pair of adaptive infinite-impulse-response filters, which enable cancellation of the artifacts generated by the simultaneous operation of the 2 on-chip stimulators. The analog front-end consumes 2.5 µW of power per channel, has a maximum gain of 50 dB and a bandwidth of 9.0 kHz with 6.2 µVrms integrated input-referred noise.

11.
J Neuroeng Rehabil ; 18(1): 117, 2021 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-34301286

RESUMO

BACKGROUND: Exercise after paralysis can help prevent secondary health complications, but achieving adequate exercise volumes and intensities is difficult with loss of motor control. Existing electrical stimulation-driven cycling systems involve the paralyzed musculature but result in rapid force decline and muscle fatigue, limiting their effectiveness. This study explores the effects of selective stimulation patterns delivered through multi-contact nerve cuff electrodes on functional exercise output, with the goal of increasing work performed and power maintained within each bout of exercise. METHODS: Three people with spinal cord injury and implanted stimulation systems performed cycling trials using conventional (S-Max), low overlap (S-Low), low duty cycle (C-Max), and/or combined low overlap and low duty cycle (C-Low) stimulation patterns. Outcome measures include total work (W), end power (Pend), power fluctuation indices (PFI), charge accumulation (Q), and efficiency (η). Mann-Whitney tests were used for statistical comparisons of W and Pend between a selective pattern and S-Max. Welch's ANOVAs were used to evaluate differences in PFIs among all patterns tested within a participant (n ≥ 90 per stimulation condition). RESULTS: At least one selective pattern significantly (p < 0.05) increased W and Pend over S-Max in each participant. All selective patterns also reduced Q and increased η compared with S-Max for all participants. C-Max significantly (p < 0.01) increased PFI, indicating a decrease in ride smoothness with low duty cycle patterns. CONCLUSIONS: Selective stimulation patterns can increase work performed and power sustained by paralyzed muscles prior to fatigue with increased stimulation efficiency. While still effective, low duty cycle patterns can cause inconsistent power outputs each pedal stroke, but this can be managed by utilizing optimized stimulation levels. Increasing work and sustained power each exercise session has the potential to ultimately improve the physiological benefits of stimulation-driven exercise.


Assuntos
Terapia por Estimulação Elétrica , Traumatismos da Medula Espinal , Estimulação Elétrica , Humanos , Fadiga Muscular , Paralisia , Traumatismos da Medula Espinal/complicações
12.
J Neuroeng Rehabil ; 18(1): 23, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33526043

RESUMO

BACKGROUND: The performance of a secondary task while walking increases motor-cognitive interference and exacerbates fall risk in older adults. Previous studies have demonstrated that transcranial direct current stimulation (tDCS) may improve certain types of dual-task performance, and, that tDCS delivered during the performance of a task may augment the benefits of stimulation, potentially reducing motor-cognitive interference. However, it is not yet known if combining multi-target tDCS with the simultaneous performance of a task related to the tDCS targets reduces or increases dual-task walking costs among older adults. The objectives of the present work were (1) To examine whether tDCS applied during the performance of a task that putatively utilizes the brain networks targeted by the neuro-stimulation reduces dual-task costs, and (2) to compare the immediate after-effects of tDCS applied during walking, during seated-rest, and during sham stimulation while walking, on dual-task walking costs in older adults. We also explored the impact on postural sway and other measures of cognitive function. METHODS: A double-blind, 'within-subject' cross-over pilot study evaluated the effects of 20 min of anodal tDCS targeting both the primary motor cortex (M1) and the left dorsolateral prefrontal cortex (lDLPFC) in 25 healthy older adults (73.9 ± 5.2 years). Three stimulation conditions were assessed in three separate sessions: (1) tDCS while walking in a complex environment (tDCS + walking), (2) tDCS while seated (tDCS + seated), and (3) walking in a complex environment with sham tDCS (sham + walking). The complex walking condition utilized virtual reality to tax motor and cognitive abilities. During each session, usual-walking, dual-task walking, quiet standing sway, and cognitive function (e.g., Stroop test) were assessed before and immediately after stimulation. Dual-task costs to gait speed and other measures were computed. RESULTS: The dual-task cost to gait speed was reduced after tDCS + walking (p = 0.004) as compared to baseline values. Neither tDCS + seated (p = 0.173) nor sham + walking (p = 0.826) influenced this outcome. Similar results were seen for other gait measures and for Stroop performance. Sway was not affected by tDCS. CONCLUSIONS: tDCS delivered during the performance of challenging walking decreased the dual-task cost to walking in older adults when they were tested just after stimulation. These results support the existence of a state-dependent impact of neuro-modulation that may set the stage for a more optimal neuro-rehabilitation. TRIAL REGISTRATION: Clinical Trials Gov Registrations Number: NCT02954328.


Assuntos
Cognição/fisiologia , Estimulação Transcraniana por Corrente Contínua/métodos , Caminhada/fisiologia , Idoso , Idoso de 80 Anos ou mais , Encéfalo/fisiologia , Método Duplo-Cego , Feminino , Humanos , Masculino , Projetos Piloto , Teste de Stroop
13.
Lasers Med Sci ; 35(2): 365-372, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31222480

RESUMO

The post-stimulation response of neural activities plays an important role to evaluate the effectiveness and safety of neural modulation techniques. Previous studies have established the capability of infrared neural modulation (INM) on neural firing regulation in the central nervous system (CNS); however, the dynamic neural activity after the laser offset has not been well characterized yet. We applied 980-nm infrared diode laser light to irradiate the primary motor cortex of rats, and tungsten electrode was inserted to record the single-unit activity of neurons at the depth of 800-1000 µm (layer V of primary motor cortex). The neural activities were assessed through the change of neural firing rate and firing pattern pre- and post-stimulation with various radiant exposures. The results showed that the 980-nm laser could modulate the firing properties of neurons in the deep layer of the cortex. More neurons with post-stimulation response (78% vs. 83%) were observed at higher stimulation intensity (0.803 J/cm2 vs. 1.071 J/cm2, respectively). The change of firing rate also increased with radiant exposures increasing, and the response lasted up to 4.5 s at 1.071 J/cm2, which was significantly longer than the theoretical thermal relaxation time. Moreover, the increasing Fano factors indicated the irregularity firing pattern of post-stimulation response. Our results confirmed that neural activity maintained a prolonged post-stimulation response after INM, which may provide necessary measurable data for optimization of INM applications in CNS.


Assuntos
Raios Infravermelhos , Córtex Motor/fisiologia , Neurônios/fisiologia , Potenciais de Ação/fisiologia , Animais , Estimulação Elétrica , Lasers Semicondutores , Masculino , Ratos Sprague-Dawley
14.
J Neuroeng Rehabil ; 17(1): 24, 2020 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-32075654

RESUMO

BACKGROUND: Leg amputees suffer the lack of sensory feedback from a prosthesis, which is connected to their low confidence during walking, falls and low mobility. Electrical peripheral nerve stimulation (ePNS) of upper-limb amputee's residual nerves has shown the ability to restore the sensations from the missing limb via intraneural (TIME) and epineural (FINE) neural interfaces. Physiologically plausible stimulation protocols targeting lower limb sciatic nerve hold promise to induce sensory feedback restoration that should facilitate close-to-natural sensorimotor integration and therefore walking corrections. The sciatic nerve, innervating the foot and lower leg, has very different dimensions in respect to upper-limb nerves. Therefore, there is a need to develop a computational model of its behavior in response to the ePNS. METHODS: We employed a hybrid FEM-NEURON model framework for the development of anatomically correct sciatic nerve model. Based on histological images of two distinct sciatic nerve cross-sections, we reconstructed accurate FEM models for testing neural interfaces. Two different electrode types (based on TIME and FINE) with multiple active sites configurations were tested and evaluated for efficiency (selective recruitment of fascicles). We also investigated different policies of stimulation (monopolar and bipolar), as well as the optimal number of implants. Additionally, we optimized the existing simulation framework significantly reducing the computational load. RESULTS: The main findings achieved through our modelling study include electrode manufacturing and surgical placement indications, together with beneficial stimulation policy of use. It results that TIME electrodes with 20 active sites are optimal for lower limb and the same number has been obtained for FINE electrodes. To interface the huge sciatic nerve, model indicates that 3 TIMEs is the optimal number of surgically implanted electrodes. Through the bipolar policy of stimulation, all studied configurations were gaining in the efficiency. Also, an indication for the optimized computation is given, which decreased the computation time by 80%. CONCLUSIONS: This computational model suggests the optimal interfaces to use in human subjects with lower limb amputation, their surgical placement and beneficial bipolar policy of stimulation. It will potentially enable the clinical translation of the sensory neuroprosthetics towards the lower limb applications.


Assuntos
Membros Artificiais , Simulação por Computador , Modelos Neurológicos , Próteses Neurais , Nervo Isquiático/fisiologia , Amputados , Retroalimentação Sensorial , Humanos , Extremidade Inferior , Masculino
15.
J Neuroeng Rehabil ; 17(1): 110, 2020 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-32799900

RESUMO

BACKGROUND: Recent studies have shown that neural stimulation can be used to provide artificial sensory feedback to amputees eliciting sensations referred on the amputated hand. The temporal properties of the neural stimulation modulate aspects of evoked sensations that can be exploited in a bidirectional hand prosthesis. METHODS: We previously collected evidence that the derivative of the amplitude of the stimulation (intra-digit temporal dynamics) allows subjects to recognize object compliance and that the time delay among stimuli injected through electrodes implanted in different nerves (inter-digit temporal distance) allows to recognize object shapes. Nevertheless, a detailed characterization of the subjects' sensitivity to variations of intra-digit temporal dynamic and inter-digit temporal distance of the intraneural tactile feedback has not been executed. An exhaustive understanding of the overall potentials and limits of intraneural stimulation to deliver sensory feedback is of paramount importance to bring this approach closer and closer to the natural situation. To this aim, here we asked two trans-radial amputees to identify stimuli with different temporal characteristics delivered to the same active site (intra-digit temporal Dynamic Recognition (DR)) or between two active sites (inter-digit Temporal distance Recognition (TR)). Finally, we compared the results achieved for (simulated) TR with conceptually similar experiments with real objects with one subject. RESULTS: We found that the subjects were able to identify stimuli with temporal differences (perceptual thresholds) larger than 0.25 s for DR and larger than 0.125 s for TR, respectively. Moreover, we also found no statistically significant differences when the subjects were asked to identify three objects during simulated 'open-loop' TR experiments or real 'closed-loop' tests while controlling robotic hand. CONCLUSIONS: This study is a new step towards a more detailed analysis of the overall potentials and limits of intraneural sensory feedback. A full characterization is necessary to develop more advanced prostheses capable of restoring all lost functions and of being perceived more as a natural limb by users.


Assuntos
Amputados/reabilitação , Membros Artificiais , Terapia por Estimulação Elétrica/métodos , Retroalimentação Sensorial/fisiologia , Tato/fisiologia , Adulto , Feminino , Mãos/fisiologia , Humanos , Pessoa de Meia-Idade , Robótica
16.
J Neuroeng Rehabil ; 17(1): 66, 2020 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-32429963

RESUMO

BACKGROUND: We hypothesized that a selective neural electrical stimulation of radial and median nerves enables the activation of functional movements in the paralyzed hand of individuals with tetraplegia. Compared to previous approaches for which up to 12 muscles were targeted through individual muscular stimulations, we focused on minimizing the number of implanted electrodes however providing almost all the needed and useful hand movements for subjects with complete tetraplegia. METHODS: We performed acute experiments during scheduled surgeries of the upper limb with eligible subjects. We scanned a set of multicontact neural stimulation cuff electrode configurations, pre-computed through modeling simulations. We reported the obtained isolated and functional movements that were considered useful for the subject (different grasping movements). RESULTS: In eight subjects, we demonstrated that selective stimulation based on multicontact cuff electrodes and optimized current spreading over the active contacts provided isolated, compound, functional and strong movements; most importantly 3 out of 4 had isolated fingers or thumb flexion, one patient performed a Key Grip, another one the Power and Hook Grips, and the 2 last all the 3 Grips. Several configurations were needed to target different areas within the nerve to obtain all the envisioned movements. We further confirmed that the upper limb nerves have muscle specific fascicles, which makes it possible to activate isolated movements. CONCLUSIONS: The future goal is to provide patients with functional restoration of object grasping and releasing with a minimally invasive solution: only two cuff electrodes above the elbow. Ethics Committee / ANSM clearance prior to the beginning of the study (inclusion period 2016-2018): CPP Sud Méditerranée, #ID-RCB:2014-A01752-45, first acceptance 10th of February 2015, amended 12th of January 2016. TRIAL REGISTRATION: (www.clinicaltrials.gov): #NCT03721861, Retrospectively registered on 26th of October 2018.


Assuntos
Terapia por Estimulação Elétrica/métodos , Nervo Mediano/cirurgia , Quadriplegia/terapia , Nervo Radial/cirurgia , Traumatismos da Medula Espinal/terapia , Adulto , Eletrodos Implantados , Antebraço/fisiopatologia , Mãos/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Quadriplegia/etiologia , Traumatismos da Medula Espinal/complicações , Adulto Jovem
17.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 37(2): 317-323, 2020 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-32329285

RESUMO

As an interface between external electronic devices and internal neural nuclei, microelectrodes play an important role in many fields, such as animal robots, deep brain stimulation and neural prostheses. Aiming at the problem of high price and complicated fabrication process of microelectrode, a microelectrode twisting machine based on open source electronic prototyping platform (Arduino) and three-dimensional printing technology was proposed, and its microelectrode fabrication performance and neural stimulation performance were verified. The results show that during the fabrication of microelectrodes, the number of positive twisting turns of the electrode wire should generally be set to about 1.8 times of its length, and the number of reverse twisting rings is independent of the length, generally about 5. Moreover, compared with the traditional instrument, the device is not only inexpensive and simple to manufacture, but also has good expandability. It has a positive significance for both the personalization and popularization of microelectrode fabrication and the reduction of experimental cost.


Assuntos
Desenho de Equipamento , Microeletrodos , Impressão Tridimensional
18.
J Musculoskelet Neuronal Interact ; 19(3): 317-325, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31475939

RESUMO

Spasticity is a sensorimotor disorder widely recognized as one of the features that contribute to patients' disability. Transcutaneous electric neural stimulation (TENS/SES) has been adopted in spasticity rehabilitation as an alternative to pharmacological agents. Although previous studies have reported clinical benefits of TENS/SES in relieving spasticity, there is no clarity on how and whether this therapeutic modality affects specific neural circuitries. Thus, this systematic review aimed to verify the efficacy of TENS/SES in the control of spasticity and its consequences in spinal and corticospinal excitability. This study was carried out according to PRISMA recommendations using SCOPUS, PubMed, BVS, Google Scholar and BASE databases screening, which provided 483 references. Six additional records were found from other sources. All these records were submitted to a filtering process following the eligibility criteria, and 44 studies were selected for further analysis. Ten were replicas. Consequently, 34 studies were read in full with the aim of checking their eligibility criterion, which resulted in 10 manuscripts for qualitative synthesis. Even though they evaluated the effects of TENS/SES both at the spinal and/or corticospinal levels, the electrophysiological results seem to be inconsistent, corroborating the lack of agreement between them and with clinical outcomes.


Assuntos
Espasticidade Muscular/terapia , Estimulação Elétrica Nervosa Transcutânea/métodos , Humanos , Resultado do Tratamento
19.
Adv Exp Med Biol ; 1101: 67-89, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31729672

RESUMO

Because of high spatial-temporal resolution of neural signals obtained by invasive recording, the invasive brain-machine interfaces (BMI) have achieved great progress in the past two decades. With success in animal research, BMI technology is transferring to clinical trials for helping paralyzed people to restore their lost motor functions. This chapter gives a brief review of BMI development from animal experiments to human clinical studies in the following aspects: (1) BMIs based on rodent animals; (2) BMI based on non-human primates; and (3) pilot BMIs studies in clinical trials. In the end, the chapter concludes with a summary of potential opportunities and future challenges in BMI technology.


Assuntos
Interfaces Cérebro-Computador , Animais , Interfaces Cérebro-Computador/normas , Interfaces Cérebro-Computador/tendências , Ensaios Clínicos como Assunto , Humanos
20.
Lasers Med Sci ; 34(8): 1555-1566, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30887233

RESUMO

In this study, we combine heat diffusion equation and modified Hodgkin-Huxley axonal model to investigate how an action potential is generated during infrared neural stimulation. The effects of temporal and spatial distribution of heat induced by infrared pulsed lasers on variation of electrical membrane capacitance are investigated. These variations can lead to depolarize the membrane and generate an action potential. We estimate the threshold values of laser light parameters such as energy density, pulse duration, and repetition rate are needed to trigger an action potential. In order to do it, we present an analytic solution to heat diffusion equation. Then, the analytic results are verified by experimental results. Furthermore, the modified Hodgkin-Huxley axonal model is applied to simulate the generation of action potential during infrared neural stimulation by taking into account the temperature dependence of electrical membrane capacitance. Results show that the threshold temperature increase induced by a train infrared pulse laser can be smaller if repetition rate is higher. These results also indicate that temperature rise time and axon diameter influence on threshold temperature increase. To verify threshold values estimated by the presented method, we use a train infrared pulsed laser (λ = 1450 nm with repetition rate of 3.8 Hz, pulse duration of 18 ms and energy density of 5 J/cm2) to optically pace an adult rat heart, and we are able to successfully pace the rat heart during an open-heart surgery. The presented method can be used to estimate threshold values of laser parameters required for generating an action potential, and it can provide an insight to how the temperature changes lead to neural stimulation during INS.


Assuntos
Raios Infravermelhos , Lasers , Sistema Nervoso/efeitos da radiação , Potenciais de Ação/efeitos da radiação , Animais , Axônios/efeitos da radiação , Membrana Celular/efeitos da radiação , Masculino , Imagens de Fantasmas , Ratos , Temperatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa