Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
World J Surg Oncol ; 21(1): 266, 2023 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-37626332

RESUMO

BACKGROUND: The number of patients with non-palpable breast lesions has increased gradually. This is because of the technological development in imaging techniques and the screening programs that lead to early detection of breast lesions. The number of patients with non-palpable breast lesions has increased gradually. This is because of the technological development in imaging techniques and the screening programs that lead to early detection of breast lesions. The aim of marking the non-palpable breast lesions is to achieve accurate lesion localization, to obtain the better cosmetic result with less tissue loss and to provide negative surgical margin. AIM OF THE STUDY: In the current study, we aimed to compare the wire-guided localization (WGL) technique with the radio-guided occult lesion localization (ROLL) technique to assess their accuracy and efficacy in non-palpable breast lesions localization. METHODS: This is a retrospective study conducted at Baheya center for Early Detection and Treatment of Breast Cancer from January 2018 and June2022,where 670 patients with non-palpable breast lesions underwent an excision were enrolled randomly in ROLL group (n = 320) and WGL (n = 350). RESULTS: Both the localization time and the time of operation were significantly decreased with the ROLL in comparison to WGL(P < 0.001). Complete lesion excision with clear margins were reported in 119/135(88.2%) of ROLL group and in 130/159 (81.8%) of WGL group and the difference was significant (P < 0.001). Reoperations (re-lumpectomy or mastectomy) were done as a second procedure on 16(11.8%) of the ROLL patients compared with 29(18.2%) in the WGL patients(P < 0.001). CONCLUSION: This study shows that ROLL is as effective as WGL for non-palpable breast lesions excision. Also, ROLL improve the outcomes by decreasing the duration of surgery, localization time, achieving a higher percentage of clear margin in spite of lower specimen size and scar length.


Assuntos
Neoplasias da Mama , Mastectomia , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Estudos Retrospectivos , Mama/diagnóstico por imagem , Mama/cirurgia , Reoperação
2.
Curr Med Imaging ; 2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38284704

RESUMO

BACKGROUND: In order to perform a full surgical resection on non-palpable breast lesions, a current method necessitates correct intraoperative localization. Additionally, because it is an important prognostic factor for these patients, the examination of the lymph node status is crucial. OBJECTIVE: The aim of this study was to evaluate the efficiency of the sentinel node and occult lesion localization (SNOLL) technique in localizing nonpalpable breast lesions together with sentinel lymph node (SLN) using a single radiotracer, that is, nanocolloid particles of human serum albumin (NC) labeled with technetium-99m (99mTc). METHODS: 39 patients were included, each having a single non-palpable breast lesion and clinically no evidence of axillary disease. Patients received 99mTc- NC intratumorally on the same day as surgery under the guidance of ultrasound. Planar and single-photon emission computed tomography/computed tomography lymphoscintigraphy were performed to localize the breast lesion and the SLN. The occult breast lesion and SLN were both localized using a hand-held gamma-probe, which was also utilized to determine the optimal access pathway for surgery. In order to ensure a radical treatment in a single surgical session and reduce the amount of normal tissue that would need to be removed, the surgical field was checked with the gamma probe after the specimen was removed to confirm the lack of residual sources of considerable radioactivity. RESULTS: Breast lesions were successfully localized and removed in all patients. Pathological findings revealed breast carcinoma in 11/39 patients (28%) and benign lesions in 28 (72%). Axillary SLNs were detected in 31/39 (79.5%) patients. The metastatic involvement of SLN was only seen in two cases. CONCLUSION: While the identification rate of the SNOLL technique performed with an intratumoral injection of 99mTc-NC as the sole radiotracer in non-palpable breast lesions was great, it was not fully satisfactory in SLNs.

3.
Indian J Surg Oncol ; 10(4): 624-628, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31857754

RESUMO

Breast cancer is one of the leading killers among women the world over. Widespread mammographic screening programs have led to almost 20% of breast cancers being detected when they are radiologically visible but clinically impalpable. For the localization of these cancers before surgical excision, the Kopan hook wire is the standard technique, but the extent of margins excised still needs to be determined. In this study, we have evaluated the accuracy of specimen mammogram (SM) with digital breast tomosynthesis (DBT) for margin assessment by comparing it to the excised margins as measured in final histopathology. This is a prospective observational study of patients with radiologically suspicious impalpable breast lesions. The patients underwent ultrasound-guided hook wire placement followed by excision of the lesion, subjected to digital tomosynthesis mammogram, and margins were revised on table when indicated. These findings were correlated with final histopathological margin. Our study included 30 patients and out of the 6 lesions, which showed positive margins on specimen mammography, 4 were histologically confirmed to have tumour at the surgical margin and 2 were confirmed to be tumour free. All DBT-positive margins were re-excised at the time of primary surgery. Individual comparison of the margins revealed a good agreement and high level of correlation between DBT and histopathology margins. None of the cases required a second surgery for margin revision. It can be concluded that specimen mammogram with DBT can be used as a reliable tool for intraoperative surgical margin assessment in non-palpable breast lesions to reduce rate of margin revision as well as reduce the volume of breast excised without compromising the oncological safety of the procedure.

4.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31248796

RESUMO

AIM: Marking of non-palpable breast lesions with 125I radioactive seeds is an alternative to the use of the surgical wire. The objective of this work is to present the results that we have obtained using radioactive seed localization compared to the reference technique in our center, the wire localization of non-palpable breast lesions. MATERIAL AND METHOD: Longitudinal prospective study that includes patients with histological diagnostic of breast cancer, with non-palpable lesions that are candidates to primary surgical treatment by radioactive seed localization (2016-2018) and by wire localization (2015-2016). Histological analysis of the surgical specimen was performed determining the status of surgical margins. The volume of the surgical specimen was calculated. RESULTS: A total of 146 patients were included, 95 who underwent surgery by radioactive seed localization and 51 by wire localization. The mean cube volume of the specimens were 135.67cm3 vs. 190.77cm3 (p=0.017), respectively. Eleven patients who underwent surgery by radioactive seed localization showed affected margins of the specimen (11.6%), versus 7 (13.2%) of wire localization group (p=0.084). Reintervention was performed in 9 of the patients marked with seeds and in 7 marked with wires (p=0.49). CONCLUSION: The use of 125I radioactive seeds is feasible in non-palpable breast lesions, with a low rate of reintervention and volumes of surgical specimens significantly lower than those obtained by wire localization.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Marcadores Fiduciais , Radioisótopos do Iodo , Cirurgia Assistida por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Feminino , Humanos , Estudos Longitudinais , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
5.
Asia Ocean J Nucl Med Biol ; 6(1): 10-14, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29333462

RESUMO

OBJECTIVES: Controversy exists about the localization of non-palpable breast lesions. In many countries, the gold standard for the diagnosis of these lesions is needle localization due to its accuracy. This study sought to compare the ultrasound- and radio-guided occult lesion localization (ROLL) as a simple method with the conventional procedures in terms of their diagnostic power. METHODS: This study was conducted on 94 patients with non-palpable breast lesions detected by ultrasonography and localized by the combination of ultrasonography and using radiopharmaceuticals. One to ten hours prior to surgery, 0.1-0.2 ml (equivalent to 0.5-1 mCi) of Tc-99m-phytate was injected to the lesion under the guidance of ultrasonography. Then, the lesion was localized using a hand-held gamma probe, and excision of the lesion was performed according to its radioactivity signal. Data analysis was performed using SPSS, version 16. RESULTS: Benign and malignant pathologic results were observed in 77 (81.9%) and 17(18.1%) of the patients, respectively, and the mean volume of the excised tissue was 26.29±27 mm³. 79 patients had a solitary lesion (84%), 55 in the left breast (58.5%) and 39 in superolateral quadrant (41.5%). The mean size of the lesions was 15.7 mm in diameter (ranging from 4 to 34 mm). Additionally, there was a need to secondary surgery in 3 (3.2%) patients and inappropriate localization in 6 (6.4%) patients (subcutaneous or intra-ductal spread of radiodrug). CONCLUSION: Combination of ultrasound- and radio-guided localization methods for localizing non-palpable breast lesions is a simple and acceptable method for localization with no significant complications. For radio-drug spread and subsequent excessive excised tissue volume, subcutaneous and intra-ductal lesions are not suitable indication for ROLL.

6.
Curr Radiopharm ; 10(3): 178-183, 2017 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-28891436

RESUMO

BACKGROUND: Due to the spread of mammographic screening programs, a constant increase of clinically-occult breast cancer diagnosis has been registered. A correct approach to nonpalpable breast lesions requires an accurate intra-operative localization in order to achieve a complete surgical resection. The aim of this paper is to describe the state of the art of the US-guided procedures such as Radio-guided Occult Lesion Localization (ROLL) and Radio-guided Seed Localization (RSL) in comparison to the most widely adopted Wire-Guided Localization (WGL). METHODS: Links to full text papers and abstracts published in the last 25 years regarding localization of non-palpable breast lesions were researched using PubMed service of US National Library of Medicine. Using the term "non-palpable breast lesions localization", different localization techniques were considered and analyzed. Human studies, published in English, French, German, Italian, and Spanish in journals with an impact factor index, were taken into account, independently of the type of article (clinical trial, review, editorial, etc.) or radiopharmaceutical used. Since the aim was to assess the clinical value of the procedures, a higher relevance was assigned to studies with significantly high number of patients and to those comparing at least two localization techniques. The reliability of each technique was evaluated taking into account several parameters such as correlation index between two localization procedures, risk of complications, lesion margin involvement and rate re-operation. CONCLUSIONS: Since their introduction in clinical practice, several randomized clinical trials and meta-analyses showed the accuracy and reliability of radio-guided procedures performed under ultrasonographic guidance. ROLL and RSL offer a practical approach to the management of clinically-occult breast lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Marcadores Fiduciais , Cintilografia/métodos , Cirurgia Assistida por Computador , Ultrassonografia de Intervenção , Detecção Precoce de Câncer , Feminino , Humanos , Biópsia Guiada por Imagem , Metástase Linfática , Radiografia Intervencionista , Compostos Radiofarmacêuticos , Biópsia de Linfonodo Sentinela
7.
J Clin Med Res ; 8(5): 389-95, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27081425

RESUMO

BACKGROUND: The aim of this study was to investigate the validity of hook wire localization biopsy for non-palpable breast lesions which were detected by ultrasonography (USG) or mammography (MMG). METHODS: In this retrospective study, USG or MMG-guided hook wire localization technique was performed on 83 patients who had non-palpable breast lesions. Then histopathological examination was performed on surgically removed specimens. All patients' mammograms or ultrasonograms were categorized using Breast Imaging-Reporting and Data System (BI-RADS) classification. RESULTS: Radiologically, 27 (32.53%) patients were classified as BI-RADS 3, 49 (59.04%) BI-RADS 4, one (1.2%) BIRADS 5 and six (7.23%) BI-RADS 0. Histopathological results were benign in 68 (81.9%) and malignant in 15 (18.1%) patients. Twenty-seven patients were classified as BI-RADS 3 and definitive diagnoses for all were benign. Besides, 49 patients were classified as BI-RADS 4 and histopathologically 14 of them were reported as malignant, and 35 as benign. Sensitivity of MMG was 93% and specificity was 55%. For USG, the sensitivity was 100% and the specificity was 73%. CONCLUSION: In early diagnosis of breast cancer, the validity of the imaging-guided hook wire localization biopsy of non-palpable breast lesions has been proved. The cooperation of surgeon, radiologist and pathologist increases the successfull results of hook wire localization technique.

8.
Artigo em Coreano | WPRIM | ID: wpr-118843

RESUMO

PURPOSE: The aim of this study was to achieve early detection, accurate diagnosis and adequate management of suspicious non-palpable breast lesions. METHODS: From January 1998 to March 2002, 86 cases of ultrasonoguided needle biopsies, 121 cases of mammographically guided needle localization biopsies and 75 cases of ultrasonographically guided needle localization biospsies were performed for a total of 282 cases of nonpalpable breast lesions. RESULTS: The age of patients ranged from 30 to 71 years with a mean age of 46.4 years. 56 cases out of a total 282 cases (20%) were found to be malignant (39.3% of those malignancies were carcinomas in situ, and 60.7% were invasive carcinomas). On a mammogram, 15.1% of the microcalcifications were found to be malignant. 31.6% of mass-like lesions and 20% of masses with microcalcifications were found to be malignant. On an ultrasonogram, 42.7% of the microcalcifications were found to be malignant. 21.1% of mass-like lesions, 30% of intraductal masses, and 31.6% of masses with microcalcifications were found to be malignant. 73.5% of all the cases of non-palpable breast cancer were found in stage 0 or 1. CONCLUSION: Non-palpable breast cancers are smaller in size and have lower chances of axillary lymph node involvement compared to palpable breast cancers. Because it is non-palpable, an early diagnosis is hard to achieve. However, once an early diagnosis is made, it could result in better prognosis. Therefore, the selection of adequate diagnostic modalities, the development of better localization methods, and training of precise surgical skill are important.


Assuntos
Humanos , Biópsia , Biópsia por Agulha , Neoplasias da Mama , Mama , Diagnóstico , Diagnóstico Precoce , Linfonodos , Agulhas , Prognóstico , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa