1.
Anal Bioanal Chem ; 415(14): 2809-2818, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37093234

RESUMO

Accurate sequencing of single guide RNAs (sgRNAs) for CRISPR/Cas9 genome editing is critical for patient safety, as the sgRNA guides the Cas9 nuclease to target site-specific cleavages in DNA. An approach to fully sequence sgRNA using protective DNA primers followed by ribonuclease (RNase) T1 digestion was developed to facilitate the analysis of these larger molecules by hydrophilic interaction liquid chromatography coupled with high-resolution mass spectrometry (HILIC-HRMS). Without RNase digestion, top-down mass spectrometry alone struggles to properly fragment precursor ions in large RNA oligonucleotides to provide confidence in sequence coverage. With RNase T1 digestion of these larger oligonucleotides, however, bottom-up analysis cannot confirm full sequence coverage due to the presence of short, redundant digestion products. By combining primer protection with RNase T1 digestion, digestion products are large enough to prevent redundancy and small enough to provide base resolution by tandem mass spectrometry to allow for full sgRNA sequence coverage. An investigation into the general requirements for adequate primer protection of specific regions of the RNA was conducted, followed by the development of a generic protection and digestion strategy that may be applied to different sgRNA sequences. This middle-out technique has the potential to expedite accurate sequence confirmation of chemically modified sgRNA oligonucleotides.


Assuntos
Sistemas CRISPR-Cas , RNA Guia de Sistemas CRISPR-Cas , Humanos , Ribonuclease T1/genética , Primers do DNA , Oligonucleotídeos , Digestão
2.
Anal Bioanal Chem ; 415(24): 6077-6089, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37516691

RESUMO

Advancing biomedical studies necessitates the development of cutting-edge technologies for the rapid extraction of nucleic acid. We characterized an RNA capture pin (RCP) tool that is non-destructive to the sample and enables rapid purification and enrichment of mRNA for subsequent genetic analysis. At the core of this technology is a pin (200 µm × 3 cm) functionalized with dT15 capture sequences that hybridize to mRNA within 2 min of insertion in the specimen. Two methods for immobilizing the oligos on the surface of the RCPs were investigated: gold-thiol and biotin-streptavidin. The RNA capture efficiency of the RCPs was assessed using a radish plant. The average reverse transcription-quantitative polymerase chain reaction (RT-qPCR) cycle amplification values were 19.93 and 24.84 for gold- and streptavidin-coated pins, respectively. The amount of RNA present on the surface of the probes was measured using the Agilent 2100 Bioanalyzer. RNA sequencing was performed to determine the mRNA selectivity of the RNA capture pin. Gene read count analysis confirmed that the RNA purified via the gold-plated RCPs contained 70% messenger RNA, 10% ribosomal RNA, and 20% non-coding RNA. The long-term stability of the bond between the dT15 oligos and the surface of the RCPs was assessed over 4 months. A significant decrease in the dT15 surface coverage of the streptavidin-coated RCPs was observed after 2 weeks of storage at 4 °C. The gold-thiol RNA capture pins exhibited a retention rate of 40% of the oligos after 4 months of storage.

3.
Anal Bioanal Chem ; 414(2): 791-806, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34738220

RESUMO

Nucleic acid analysis is used in many areas of life sciences such as medicine, food safety, and environmental monitoring. Accurate, reliable measurements of nucleic acids are crucial for maximum impact, yet users are often unaware of the global metrological infrastructure that exists to support these measurements. In this work, we describe international efforts to improve nucleic acid analysis, with a focus on the Nucleic Acid Analysis Working Group (NAWG) of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM). The NAWG is an international group dedicated to improving the global comparability of nucleic acid measurements; its primary focus is to support the development and maintenance of measurement capabilities and the dissemination of measurement services from its members: the National Metrology Institutes (NMIs) and Designated Institutes (DIs). These NMIs and DIs provide DNA and RNA measurement services developed in response to the needs of their stakeholders. The NAWG members have conducted cutting edge work over the last 20 years, demonstrating the ability to support the reliability, comparability, and traceability of nucleic acid measurement results in a variety of sectors.


Assuntos
Ácidos Nucleicos/análise , Ácidos Nucleicos/normas , Padrões de Referência , Reprodutibilidade dos Testes
4.
Anal Bioanal Chem ; 410(17): 4135-4144, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29704032

RESUMO

Nucleic acid extraction and purification represents a major bottleneck in DNA analysis. Traditional methods for DNA purification often require reagents that may inhibit quantitative polymerase chain reaction (qPCR) if not sufficiently removed from the sample. Approaches that employ magnetic beads may exhibit lower extraction efficiencies due to sedimentation and aggregation. In this study, four hydrophobic magnetic ionic liquids (MILs) were investigated as DNA extraction solvents with the goal of improving DNA enrichment factors and compatibility with downstream bioanalytical techniques. By designing custom qPCR buffers, we directly incorporated DNA-enriched MILs including trihexyl(tetradecyl)phosphonium tris(hexafluoroacetylaceto)nickelate(II) ([P6,6,6,14+][Ni(hfacac)3-]), [P6,6,6,14+] tris(hexafluoroacetylaceto)colbaltate(II) ([Co(hfacac)3-]), [P6,6,6,14+] tris(hexafluoroacetylaceto)manganate(II) ([Mn(hfacac)3-]), or [P6,6,6,14+] tetrakis(hexafluoroacetylaceto)dysprosate(III) ([Dy(hfacac)4-]) into reaction systems, thereby circumventing the need for time-consuming DNA recovery steps. Incorporating MILs into the reaction buffer did not significantly impact the amplification efficiency of the reaction (91.1%). High enrichment factors were achieved using the [P6,6,6,14+][Ni(hfacac)3-] MIL for the extraction of single-stranded and double-stranded DNA with extraction times as short as 2 min. When compared to a commercial magnetic bead-based platform, the [P6,6,6,14+][Ni(hfacac)3-] MIL was capable of producing higher enrichment factors for single-stranded DNA and similar enrichment factors for double-stranded DNA. The MIL-based method was applied for the extraction and direct qPCR amplification of mutation prone-KRAS oncogene fragment in plasma samples. Graphical abstract Magnetic ionic liquid solvents are shown to preconcentrate sufficient KRAS DNA template from an aqueous solution in as short as 2 min without using chaotropic salts or toxic organic solvents. By using custom-designed qPCR buffers, DNA can be directly amplified and quantified from four MILs examined in this study.


Assuntos
DNA/química , Líquidos Iônicos , Magnetismo , Ácidos Nucleicos/análise , Reação em Cadeia da Polimerase em Tempo Real/métodos , Técnicas de Química Analítica , Interações Hidrofóbicas e Hidrofílicas , Estrutura Molecular , Espectrofotometria Atômica
5.
Anal Bioanal Chem ; 409(17): 4119-4126, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28512717

RESUMO

Infrared (IR) laser ablation was used to remove material from tissue sections mounted on microscope slides, with subsequent capture in a solvent-containing microcentrifuge tube. Experiments conducted with a 3200-bp double-stranded plasmid DNA template demonstrated IR-laser ablation transfer of intact DNA. The transfer efficiency and the molecular integrity of the captured DNA were evaluated using Sanger sequencing, gel electrophoresis, and fluorimetric analysis. The plasmid DNA was reproducibly transferred with an efficiency of 59 ± 3% at laser fluences of between 10 and 20 kJ/m2 at a wavelength of 3 µm. IR laser ablation sample transfer was then used to ablate and capture DNA from 50-µm-thick rat brain and kidney tissue sections. DNA was extracted from the captured material using five commercial DNA extraction kits that employed significantly divergent methodologies, with all kits recovering sufficient DNA for successful amplification by polymerase chain reaction (PCR). Four sets of primers were employed, targeting one region of the CYP 11b2 gene (376 bp) and three different regions of the Snn1g gene (298, 168, and 281 bp). The PCR results were not consistently reliable when using unpurified ablation samples; however, after extraction, all samples produced PCR products of the expected size. This work expands the sampling capabilities of IR laser ablation, demonstrating that DNA can be isolated from tissue samples for genomic assays. Due to the small size of the ablation regions (1 mm2), this technique will be useful for sampling discrete cell populations from tissue sections. Graphical abstract Infrared laser ablation transfer of intact DNA from a tissue section.


Assuntos
DNA/análise , Genômica/métodos , Terapia a Laser/métodos , Animais , Sequência de Bases , Raios Infravermelhos , Reação em Cadeia da Polimerase/métodos , Ratos , Manejo de Espécimes