Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(2): 328-340, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38105441

RESUMO

INTRODUCTION: The aim of the current study was to elucidated the reliable atrial fibrillation (AF) drivers identified by CARTOFINDER using OctaRay catheter. METHODS AND RESULTS: The reliability of focal and rotational activations identified by CARTOFINDER using OctaRay catheter was assessed by the sequential recordings in each site of both atrium before and after pulmonary vein isolation (PVI) in 10 persistent AF patients. The outcome measures were the reproducibility rate during the sequential recordings and the stability rate between pre- and post-PVI as reliable focal and rotational activations. The study results were compared with those under use of PentaRay catheter (N = 18). Total 68928 points of 360 sites in OctaRay group and 24 177 points of 311 sites in PentaRay were assessed. More focal activation sites were identified in OctaRay group than PentaRay group (7.9% vs. 5.7%, p < .001), although the reproducibility rate and the stability rate were significantly lower in OctaRay group (45.3% vs. 58.9%, p < .001; 11.2% vs. 28.4%, p < .001). Meanwhile, the prevalence of reproducible focal activation sites among overall points was comparable (3.6% vs. 3.3%, p = .08). Regarding rotational activation, more rotational activation sites were identified in OctaRay group (5.1% vs. 0.2%, p < .001), and the reproducibility rate and the stability rate were significantly higher in OctaRay group (45.2% and 12.5% vs. 0.0%, p < .001). Both reliable focal and rotational activation sites were characterized by significantly shorter AF-cycle length (CL) and higher repetition of focal and rotational activations during the recordings compared with the sites of non or unreliable focal and rotational activations. CONCLUSION: In CARTOFINDER, OctaRay catheter could identify reliable focal activation with high resolution and reliable rotational activation compared with PentaRay catheter. The repetitive focal and rotational activations with short AF-CL could be the potential target during ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Frequência Cardíaca , Reprodutibilidade dos Testes , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Catéteres , Veias Pulmonares/cirurgia , Resultado do Tratamento
2.
Artigo em Inglês | MEDLINE | ID: mdl-38430486

RESUMO

The majority of the cavotricuspid isthmus (CTI) region consists of discretely arranged muscle bundles separated by connective tissue. Heterogeneity in the anatomic arrangement of the muscle bundles results in differences in the endocardial and epicardial activation patterns. We present a case of recurrent atrial flutter (AFL) despite the presence of a complete endocardial CTI block. We found epicardial-endocardial breakthrough (EEB) sites on the right atrial high septum. In addition, the epicardial excitation confirmed by endocardial activation mapping was detected as far-field potentials. Radiofrequency ablation was performed at the EEB site. No AFL has recurred for 12 months after the present procedure.

3.
JACC Clin Electrophysiol ; 8(9): 1067-1076, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35780035

RESUMO

BACKGROUND: The Octaray (Biosense Webster) is a novel, multispline mapping catheter with 48 closely spaced microelectrodes enabling high-resolution electroanatomical mapping. OBJECTIVES: This study sought to report the initial clinical mapping experience with this novel catheter in a variety of cardiac arrhythmias and to compare the mapping performance with the 5-spline Pentaray. METHODS: Fifty consecutive procedures among 46 patients were retrospectively analyzed regarding safety, efficacy, and acute procedural success defined as termination or noninducibility of clinical tachycardia, conduction block across an ablation line, or pulmonary vein isolation. In addition, another 10 patients with sustained atrial tachycardia mapped with the 5-spline catheter (2-5-2 spacing) or the novel 8-spline catheter (2-2-2-2-2 spacing) were analyzed. RESULTS: Left atrial and ventricular mapping by either transseptal (n = 41) or retroaortic (n = 2) access was feasible without any complications related to the multispline design of the novel catheter. The acute procedural success rate was 94%. In sustained atrial tachycardia compared with the 5-spline catheter, the novel 8-spline catheter recorded more electrograms per map (3,628 ± 714 vs 11,350 ± 1,203; P < 0.001) in a shorter mapping time (13 ± 2 vs 9 ± 1 minutes; P = 0.08) resulting in a higher point density (18 ± 4 vs 59 ± 10 electrograms/cm2; P < 0.01) and point acquisition rate (308 ± 69 vs 1,332 ± 208 electrograms/min.; P < 0.01). CONCLUSIONS: In this initial experience, mapping with the novel catheter was safe and efficient with a high electroanatomical resolution. In sustained atrial tachycardia the novel 8-spline catheter demonstrated a marked increase in point density and mapping speed compared with those of the 5-spline catheter. These initial results should be validated in a larger multicenter cohort with longer follow-up.


Assuntos
Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Humanos , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Taquicardia Supraventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa