Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Dig Dis Sci ; 64(9): 2631-2637, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31041643

RESUMO

INTRODUCTION: Jaundice is a common initial presentation of malignant biliary stricture. In patients with life expectancies that are greater than 3 months, self-expanding metal stents (SEMS) offer a larger diameter stent with longer patency and fewer complications compared to plastic stents. There have been conflicting results in the published literature as to efficacy and safety between the various SEMS types and diameters. We compared stent coating (PCSEMS vs USEMS) and diameter on clinical outcomes regarding management of malignant biliary obstruction. METHODS: A retrospective cohort study was conducted using a database of consecutive patients who underwent an ERCP with biliary SEMS placement (only 8 and 10 mm) between 2009 and 2017. RESULTS: In total, 278 patients who had SEMS at ERCP for malignant biliary obstruction were included (213 PCSEMS vs 65 USEMS). The groups were demographically evenly matched. Clinical success rates and patency duration were not statistically significant between PCSEMS and USEMS (98.1% vs 95.5%, P = 0.36, and 302.5 vs 225.5 days, P = 0.72, respectively). Adverse event rates were similar between both PCSEMS and USEMS with regard to overall adverse events. Stent diameter did not have an impact on overall clinical success (98.9% vs 95.3%, P = 0.11) or patency duration (239 days vs 336 days, P = 0.51). CONCLUSIONS: Our comparison of PCSEMS versus USEMS and 8 mm versus 10 mm showed no difference in clinical efficacy or adverse events between the two SEMS coatings and diameter, illustrating that coating and size do not matter in regard to stent choice, despite prior suggestive data.


Assuntos
Colestase/diagnóstico , Colestase/cirurgia , Stents Metálicos Autoexpansíveis/tendências , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Bases de Dados Factuais/tendências , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese/tendências , Estudos Retrospectivos , Stents Metálicos Autoexpansíveis/normas , Resultado do Tratamento
2.
VideoGIE ; 7(12): 442-444, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36467526

RESUMO

Video 1Cryotherapy for removal of an embedded, partially covered esophageal stent.

3.
VideoGIE ; 6(7): 322-324, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34278097

RESUMO

Video 1EUS-guided hepaticogastrostomy with a novel partially covered self-expandable metallic stent for a patient with biliary obstruction owing to gallbladder cancer.

4.
Obes Surg ; 28(1): 161-168, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28695460

RESUMO

BACKGROUND AND AIMS: Partially covered self-expandable metallic stents (PCSEMS), although an effective treatment for anastomotic/staple line leaks and strictures, can be difficult to remove. This study examines the effectiveness of the inversion technique for the removal of PCSEMS in the treatment of leaks and strictures that occurred post-sleeve gastrectomy (SG) and Roux-en-Y gastric bypass (RYGB). METHODS: Consecutive patients who underwent PCSEMS removal for a leak and/or stricture post-SG or RYGB between July 2013 and December 2016 at the Johns Hopkins Medical Institutions were reviewed. All PCSEMS removals were first attempted via the inversion technique, which involves grasping the distal end of the stent and inverting it through itself. RESULTS: Fourteen patients (four males) underwent PCSEMS removal via the inversion technique for an anastomotic/staple line leak (50%), stricture (29%) or both (21%) post-SG (79%) or RYGB (21%). Technical success (successful removal of the stent) was achieved in one endoscopic session for 13 of the 14 PCSEMS (93%). One PCSEMS required the use of the stent-in-stent technique for removal. The median dwell time was 47 days (range 5-72). A distal partial occlusion developed in five patients (35%) due to tissue overgrowth and one PCSEMS (7%) migrated, necessitating premature removal. Eight patients (57%) experienced clinical success at follow-up, and six patients (43%) required subsequent treatment due to persistence or recurrence of the pathology. CONCLUSIONS: The inversion technique is a safe, effective, and efficient method of removing PCSEMS placed to correct anastomotic/staple line leaks and strictures post-SG and RYGB.


Assuntos
Fístula Anastomótica/etiologia , Fístula Anastomótica/cirurgia , Remoção de Dispositivo/métodos , Endoscopia Gastrointestinal , Gastrectomia/efeitos adversos , Derivação Gástrica/efeitos adversos , Obesidade Mórbida/cirurgia , Stents Metálicos Autoexpansíveis , Adulto , Idoso , Constrição Patológica/cirurgia , Remoção de Dispositivo/efeitos adversos , Endoscopia Gastrointestinal/instrumentação , Endoscopia Gastrointestinal/métodos , Feminino , Gastrectomia/instrumentação , Gastrectomia/métodos , Derivação Gástrica/instrumentação , Derivação Gástrica/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/instrumentação , Reoperação/métodos , Estudos Retrospectivos , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/instrumentação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS