Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
J Intensive Care Med ; 39(4): 341-348, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37769347

RESUMO

PURPOSE: Bedside transthoracic echocardiography (TTEcho) is a noninvasive cardiac output (CO) monitoring method that has grown recently. However, there are questions regarding its accuracy compared to invasive methods. We aimed to evaluate the agreement and correlation of TTEcho and pulse index continuous CO (PiCCO) monitor measurements for CO and systolic volume (SV) in critically ill patients. METHODS: This prospective experimental study included consecutive adult patients who required invasive hemodynamic monitoring admitted at an intensive care unit in the Federal District, Brazil, from January/2019 to January/2021. Correlation and agreement between SV and CO measurements by PiCCO and TTEcho were performed using the Spearman correlation and the Bland-Altman analysis. RESULTS: The study enrolled 29 patients, with adequate TTEcho evaluations in all patients. There were very strong correlations between CO-TTEcho and CO-PiCCO (r = 0.845, P < .001) and SV-TTEcho and SV-PiCCO (r = 0.800, P < .001). TTEcho estimations for CO and SV were feasible within the limits of agreement in 96.6% (28/29) compared to PiCCO. The mean difference between CO-PiCCO and CO-TTEcho was 0.250 L/min (limits of agreement: -1.083 to 1.583 L/min, percentage error: 21.0%), and between SV-PiCCO and SV-TTEcho was 2.000 mL (limits of agreement: -16.960 to 20.960, percentage error: 24.3%). The reduced cardiac index (CI) measurements by TTEcho showed an accuracy of 89.7% (95% IC: 72.6%-97.8%) and an F1 score of 92.7% (95% IC: 75.0%-98.0%), considering the CI-PiCCO as the gold standard. CONCLUSION: Echocardiographic measurements of CO and SV are comparable to measurements by PiCCO. These results reinforce echocardiography as a reliable tool to evaluate hemodynamics in critically ill patients.


Assuntos
Estado Terminal , Ecocardiografia , Adulto , Humanos , Volume Sistólico , Estudos Prospectivos , Débito Cardíaco , Monitorização Fisiológica/métodos
2.
BMC Anesthesiol ; 24(1): 201, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844869

RESUMO

BACKGROUND: Significant hemodynamic changes occur during liver transplantation, emphasizing the importance of precious and continuous monitoring of cardiac output, cardiac index, and other parameters. Although the monitoring of cardiac output by pulse indicator continuous cardiac output (PiCCO) was statistically homogeneous compared to the clinical gold standard pulmonary artery catheterization (PAC) in previous studies of liver transplantation, there are fewer statistical methods for the assessment of its conclusions, and a lack of comparisons of other hemodynamic parameters (e.g., SVRI, systemic vascular resistance index). Some studies have also concluded that the agreement between PiCCO and PAC is not good enough. Overall, there are no uniform conclusions regarding the agreement between PiCCO and PAC in previous studies. This study evaluates the agreement and trending ability of relevant hemodynamic parameters obtained with PiCCO compared to the clinical gold standard PAC from multiple perspectives, employing various statistical methods. METHODS: Fifty-two liver transplantation patients were included. Cardiac output (CO), cardiac index (CI), SVRI and stroke volume index (SVI) values were monitored at eight time points using both PiCCO and PAC. The results were analyzed by Bland-Altman analysis, Passing-bablok regression, intra-class correlation coefficient (ICC), 4-quadrant plot, polar plot, and trend interchangeability method (TIM). RESULTS: The Bland-Altman analysis revealed high percentage errors for PiCCO: 54.06% for CO, 52.70% for CI, 62.18% for SVRI, and 51.97% for SVI, indicating poor accuracy. While Passing-Bablok plots showed favorable agreement for SVRI overall and during various phases, the agreement for other parameters was less satisfactory. The ICC results confirmed good overall agreement between the two devices across most parameters, except for SVRI during the new liver phase, which showed poor agreement. Additionally, four-quadrant and polar plot analyses indicated that all agreement rate values fell below the clinically acceptable threshold of over 90%, and all angular deviation values exceeded ± 5°, demonstrating that PiCCO is unable to meet the acceptable trends. Using the TIM, the interchangeability rates were found to be quite low: 20% for CO and CI, 16% for SVRI, and 13% for SVI. CONCLUSIONS: Our study revealed notable disparities in absolute values of CO, CI, SVRI and SVI between PiCCO and PAC in intraoperative liver transplant settings, notably during the neohepatic phase where errors were particularly pronounced. Consequently, these findings highlight the need for careful consideration of PiCCO's advantages and disadvantages in liver transplantation scenarios, including its multiple parameters (such as the encompassing extravascular lung water index), against its limited correlation with PAC.


Assuntos
Débito Cardíaco , Cateterismo de Swan-Ganz , Hemodinâmica , Transplante de Fígado , Monitorização Intraoperatória , Transplante de Fígado/métodos , Humanos , Cateterismo de Swan-Ganz/métodos , Débito Cardíaco/fisiologia , Masculino , Pessoa de Meia-Idade , Feminino , Hemodinâmica/fisiologia , Monitorização Intraoperatória/métodos , Idoso , Adulto , Artéria Pulmonar/fisiologia
3.
Yale J Biol Med ; 96(1): 107-123, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-37009197

RESUMO

Goal-directed fluid therapy (GDFT) is usually recommended in patients undergoing major surgery and is essential in enhanced recovery after surgery (ERAS) protocols. This fluid regimen is usually guided by dynamic hemodynamic parameters and aims to optimize patients' cardiac output to maximize oxygen delivery to their vital organs. While many studies have shown that GDFT benefits patients perioperatively and can decrease postoperative complications, there is no consensus on which dynamic hemodynamic parameters to guide GDFT with. Furthermore, there are many commercialized hemodynamic monitoring systems to measure these dynamic hemodynamic parameters, and each has its pros and cons. This review will discuss and review the commonly used GDFT dynamic hemodynamic parameters and hemodynamic monitoring systems.


Assuntos
Objetivos , Complicações Pós-Operatórias , Humanos , Hemodinâmica , Hidratação/métodos
4.
Pak J Med Sci ; 39(1): 214-218, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36694729

RESUMO

Objectives: To investigate whether pulse index continuous cardiac output (PiCCO) and critical care ultrasound are highly consistent in volume status assessment during fluid resuscitation for septic shock patients and analyze their influence on the prognosis of septic shock. Methods: Eighty septic shock patients treated by Huizhou Central People's Hospital during December 2018 and December 2020 were included and divided into a study group and a control group by the presence of volume responsiveness, with each group having 40 patients. The control group was subject to PiCCO-guided fluid resuscitation therapy, while the study group was given fluid resuscitation therapy guided by critical care ultrasound. Cardiac output, cardiac function, and catheter-related infection (CRI) were documented for intergroup comparison to confirm whether these two techniques were consistent with each other regarding their effects on resuscitation for and prognosis of septic shock patients. Results: Mechanical ventilation duration (MVD) and intensive care unit (ICU) length of stay (LoS) were significantly shorter in the study group when compared with the control group, and the differences were statistically significant (p<0.05, respectively). In terms of blood pressure parameters, the two groups did not differ greatly in diastolic blood pressure (DBP), mean arterial pressure (MAP), systolic blood pressure (SBP), and central venous pressure (CVP) before resuscitation (p>0.05, respectively); at 6h(six hour) after resuscitation, DBP, MAP, SBP, and CVP were substantially increased in both groups as compared with the pre-resuscitation levels (all p<0.05), but the differences between the two groups lacked statistical significance (all p>0.05). Comparing urine volume and degrees of positive fluid balance at 6 h and 12 h after resuscitation, drastic increases in urine volume and positive fluid balance were observed in both groups at 12 h as compared with at 6 h (all p<0.05); nevertheless, the two groups showed no statistically significant difference in urine volume and positive fluid balance at 6 h or 12 h (p>0.05, respectively). With regards to prognosis, there was no statistically significant difference between the two groups in the number of cases of continuous renal replacement therapy (CRRT), dosage of vasoactive agents and 28-d mortality rate (all p>0.05). However, the incidence of CRI was markedly lower in the study group (0/40) as compared with the control group (5/40), and the difference was statistically significant (p<0.05). Conclusions: Both PiCCO and critical care ultrasound can help achieve favorable outcomes from resuscitation for septic shock patients. Compared with PiCCO, critical care ultrasound monitoring appears to be more effective in preventing CRI and reducing MVD and ICU LoS, thereby easing patients' medical burden.

5.
Clin Transplant ; 36(10): e14643, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35262975

RESUMO

BACKGROUND: Liver transplant centers vary in approach to intraoperative vascular accesses, monitoring of cardiac function and temperature management. Evidence is limited regarding impact of selected modalities on postoperative outcomes. OBJECTIVES: To review the literature and provide expert panel recommendations on optimal intraoperative arterial blood pressure (BP), central venous pressure (CVP), and vascular accesses, monitoring of cardiac function and intraoperative temperature management regarding immediate and short-term outcomes after orthotopic liver transplant (OLT). METHODS: Systematic review following PRISMA guidelines and recommendations using the GRADE approach derived from an international expert panel. Recommendations made for: (1) Vascular accesses, arterial BP and CVP monitoring, (2) cardiac function monitoring, and (3) Intraoperative temperature management (CRD42021239908). RESULTS: Of 2619 articles screened 16 were included. Studies were small, retrospective, and observational. Vascular access studies demonstrated low rates of insertion complications. TEE studies demonstrated low rates of esophageal hemorrhage. One study found lower hospital-LOS and 30-day mortality in patients monitored with both PAC and TEE. Other monitoring studies were heterogenous in design and outcomes. Temperature studies showed increased blood transfusion and ventilation times in hypothermic groups. CONCLUSIONS: Recommendations were made for; routine arterial and CVP monitoring as a minimum standard of practice, consideration of discrepancy between peripheral and central arterial BP in patients with hemodynamic instability and high vasopressor requirements, and routine use of high flow cannulae while monitoring for extravasation and hematoma formation. Availability and expertise in PAC and/or TEE monitoring is strongly recommended particularly in hemodynamic instability, portopulmonary HT and/or cardiac dysfunction. TEE use is recommended as an acceptable risk in patients with treated esophageal varices and is an effective diagnostic tool for emergency cardiovascular collapse. Maintenance of intraoperative normothermia is strongly recommended.


Assuntos
Transplante de Fígado , Humanos , Transplante de Fígado/efeitos adversos , Estudos Retrospectivos , Monitorização Intraoperatória , Pressão Venosa Central , Vasoconstritores
6.
J Clin Monit Comput ; 36(1): 141-145, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33398546

RESUMO

Thermodilution cardiac output monitoring, using a thermistor-tipped intravascular catheter, is used in critically ill patients to guide hemodynamic therapy. Often, these patients also need magnetic resonance imaging (MRI) for diagnostic or prognostic reasons. As thermodilution catheters contain metal, they are considered MRI-unsafe and advised to be removed prior to investigation. However, removal and replacement of the catheter carries risks of bleeding, perforation and infection. This research is an in vitro safety assessment of the PiCCO™ thermodilution catheter during 3 T Magnetic Resonance Imaging (3T-MRI).  In a 3T-MRI environment, three different PiCCO™ catheter sizes were investigated in an agarose-gel, tissue mimicking phantom. Two temperature probes measured radiofrequency-induced heating; one at the catheter tip and one at a reference point. Magnetically induced catheter dislocation was assessed by visual observation as well as by analysis of the tomographic images. For all tested catheters, the highest measured temperature increase was 0.2 °C at the center of the bore and 0.3 °C under "worst-case" setting for the tested MRI pulse sequences. No magnetically induced catheter displacements were observed. Under the tested circumstances, no heating or dislocation of the PiCCO™ catheter was observed in a tissue mimicking phantom during 3T-MRI. Leaving the catheter in the critically ill patient during MRI investigation might pose a lower risk of complications than catheter removal and replacement.


Assuntos
Estado Terminal , Termodiluição , Débito Cardíaco , Catéteres , Humanos , Imageamento por Ressonância Magnética , Termodiluição/métodos
7.
J Intensive Care Med ; 36(5): 589-596, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32208899

RESUMO

BACKGROUND: Vasoplegia is vascular hyporesponsiveness to vasopressors and is an important phenomenon in children with refractory septic shock. This study aimed to develop an objective formula correlated with vasoplegia and evaluate the predictive power for mortality in children with refractory septic shock. MATERIALS AND METHODS: We retrospectively analyzed children with refractory septic shock admitted to a pediatric intensive care unit (PICU) and monitored their hemodynamics via a pulse index continuous cardiac output (PiCCO) system. Serial hemodynamic data including cardiac index (CI), systemic vascular resistant index (SVRI) and vasoactive-inotropic score (VIS) were recorded during the first 72 hours after PICU admission. We defined vascular reactivity index (VRI) as SVRI/VIS and analyzed the effect of VRI in predicting mortality in children with refractory septic shock. RESULTS: Thirty-three children with refractory septic shock were enrolled. The SVRI was lower in the mortality group compared to the survival group (P < .05). The average area under the receiver operating characteristic curve of VRI within the first 72 hours was 0.8 and the serial values of VRI were significantly lower in the mortality group during the period from 0 to 48 hours (P < .05). However, there were no significant differences in serial CI values between the survival and mortality groups. CONCLUSIONS: Vasoactive-inotropic score may potentially be used to quantify the severity of vasoplegia based on the clinical response of vessels after resuscitation with vasopressors. Lower VRI levels may indicate a higher risk of mortality in children with septic shock.


Assuntos
Choque Séptico , Choque , Débito Cardíaco , Criança , Humanos , Ressuscitação , Estudos Retrospectivos
8.
Aust Crit Care ; 34(3): 241-245, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33060047

RESUMO

BACKGROUND: The assessment of the volume status in critically ill paediatric patients in intensive care units is vitally important for fluid therapy management. The most commonly used parameter for detecting volume status is still central venous pressure (CVP); however, in recent years, various kinds of methods and devices are being used for volume assessment in intensive care units. OBJECTIVES: We aimed to evaluate the relationship between CVP, the global end-diastolic index (GEDI), and ultrasound measurements of the collapsibility and distensibility indices of the inferior vena cava (IVC) in paediatric patients undergoing Pulse index Contour Cardiac Output (PiCCO) monitoring. METHODS: Fifteen patients receiving PiCCO monitoring were prospectively included in the study. Forty-nine PiCCO measurements were evaluated, and simultaneous CVP values were noted. After each measurement, IVC collapsibility (in spontaneously breathing patients) and distensibility (in mechanically ventilated patients) indices were measured with bedside ultrasound. RESULTS: The mean age was 93.2 ± 61.3 months. Significant and negative correlations of the GEDI were found with the IVC collapsibility index (in spontaneously breathing patients) and the IVC distensibility index (in mechanically ventilated patients) (r = -0.502, p < 0.001; r = -0.522, p = 0.001, respectively). A significant and weakly positive correlation was found between the GEDI and CVP (r = 0.346, p = 0.015), and a significant and negative correlation was found between the IVC collapsibility index and CVP (r = -0.482, p = 0.03). The correlation between the IVC distensibility index and CVP was significant and negative (r = -0.412, p = 0.04). CONCLUSION: The use of PiCCO as an advanced haemodynamic monitoring method and the use of bedside ultrasound as a noninvasive method are useful to evaluate the volume status in critically ill paediatric patients in intensive care. These methods will gradually come to the fore in paediatric intensive care.


Assuntos
Estado Terminal , Veia Cava Inferior , Pressão Venosa Central , Criança , Humanos , Projetos Piloto , Estudos Prospectivos , Ultrassonografia , Veia Cava Inferior/diagnóstico por imagem
9.
J Pak Med Assoc ; 70 [Special Issue](9): 51-56, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33177728

RESUMO

OBJECTIVE: To investigate volume management by comparing between critical care ultrasound examination and pulse indicator cardiac output (PICCO) in patient with septic shock. METHODS: Patients with septic shock during July 2017 and June 2018 were included. Inferior Vena Cava (IVC), total end-diastolic volume index (GEDI), central venous pressure (CVP), lactic acid and oxygenation index were measured by ultrasound. First, the accuracy difference of IVC, GEDI and CVP estimation capacity was compared. According to the changes of IVCmin, IVCmax, and GEDI, they were divided into 5 groups to compare the differences of lactic acid and oxygenation index between the groups and the correlation of lactate and Oxygenation index (PaO2/FiO2) between IVC and GEDI was analyzed. The correlation of lactate and PaO2/FiO2 between B lines and extravascular pulmonary water index (ELWI) was noted. RESULTS: The accuracy of IVC and GEDI in volume estimation was greater than 75%, significantly higher than that of CVP (53.3%) (P<0.05). The correlation results showed that GEDI was significantly correlated with IVCmax and IVCmin (P<0.05), while there was a significant correlation between b-line area and oxygenation index, ELWI and lactic acid, ELWI and oxygenation index (P<0.05). IVCmin, IVCmax and GEDI were respectively divided into 5 groups for comparing the difference between lactic acid and oxygenation. It was found that there were significant differences between the two indicators of IVCmin in different groups (P>0.05). The oxygenation index of the group ≤IVCmax was significantly lower than that of the group 0.5 ≤IVCmax < 1.0cm (P<0.05). The oxgenation indexes of groups 500≤GEDI < 600mL/m2; 600≤GEDI < 700mL/m2. 700≤GEDI < 800mL/m2 were significantly higher than that of group 0 < GEDI < 500mL/m2 (P<0.05). CONCLUSIONS: Critical care ultrasound examination and PICCO are better methods than in volume management, but PICCO is more individualized, and PICCO in patients with valvular heart disease is not recommended.


Assuntos
Choque Séptico , Débito Cardíaco , Pressão Venosa Central , Cuidados Críticos , Hidratação , Humanos
10.
J Cardiothorac Vasc Anesth ; 32(4): 1731-1735, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29203299

RESUMO

OBJECTIVES: First evaluation of the transpulmonary thermodilution technique by the PiCCO2 device to assess cardiac index and pulmonary edema during the postoperative course after single-lung transplantation. DESIGN: Prospective observational study. SETTINGS: Intensive care unit, university hospital (single center). PARTICIPANTS: Single-lung transplant patients. INTERVENTIONS: The authors compared cardiac index measured by PiCCO2 and pulmonary artery catheter and assessed pulmonary edema using extravascular lung water index and pulmonary vascular permeability index measured by PiCCO2. MEASUREMENTS AND MAIN RESULTS: A Bland-Altman method was used to compare cardiac index measured by PiCCO2 and pulmonary artery catheter. Extravascular lung water index and pulmonary vascular permeability index were compared according to the PaO2/FiO2 ratio with a threshold value of 150 mmHg. Ten single-lung transplant patients were included. Cardiac index measured by PiCCO2 and pulmonary artery catheter were 3.3 L/min/m2 (2.9-3.6) and 2.5 L/min/m2 (2.2-3.0). Bias for cardiac index was 0.71 L/min/m2 (-0.03; 1.44) and limit of agreements were -0.03 and 1.44 L/min/m2. Extravascular lung water index was 12 mL/kg (11-16) and pulmonary vascular permeability index was 2.3 (2.0-3.1), consistent with pulmonary edema. Extravascular lung water index was higher in the group of PaO2/FiO2 ratio ≤150 mmHg compared with the group of PaO2/FiO2 ratio >150 mmHg (17 v 12 mL/kg, p = 0.04), whereas pulmonary vascular permeability index only tended to be higher (3.1 v 2.1, p = 0.06). CONCLUSION: PiCCO2 device systematically overestimated cardiac index compared with pulmonary artery catheter. However, it might be useful to assess pulmonary edema in acute respiratory failure after single-lung transplantation.


Assuntos
Débito Cardíaco/fisiologia , Cateterismo Periférico/tendências , Água Extravascular Pulmonar/fisiologia , Transplante de Pulmão/tendências , Pulmão/fisiologia , Cateterismo Periférico/métodos , Feminino , Humanos , Pulmão/irrigação sanguínea , Transplante de Pulmão/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Termodiluição/métodos
11.
BMC Anesthesiol ; 17(1): 98, 2017 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-28738837

RESUMO

BACKGROUND: The aim of the present work was to assess cerebral hemodynamic changes in a porcine model of E.coli induced fulminant sepsis. METHODS: Nineteen healthy female Hungahib pigs, 10-12 weeks old, randomly assigned into two groups: Control (n = 9) or Septic Group (n = 10). In the Sepsis group Escherichia coli culture suspended in physiological saline was intravenously administrated in a continuously increasing manner according to the following protocol: 2 ml of bacterial culture suspended in physiological saline was injected in the first 30 min, then 4 ml of bacterial culture was administered within 30 min, followed by infusion of 32 ml bacterial culture for 2 h. Control animals received identical amount of saline infusion. Systemic hemodynamic parameters were assessed by PiCCo monitoring, and cerebral hemodynamics by transcranial Doppler sonography (transorbital approach) in both groups. RESULTS: In control animals, systemic hemodynamic variables and cerebral blood flow velocities and pulsatility indices were relatively stable during the entire procedure. In septic animals shock developed in 165 (IQR: 60-255) minutes after starting the injection of E.coli solution. Blood pressure values gradully decreased, whereas pulse rate increased. A decrease in cardiac index, an increased systemic vascular resistance, and an increased stroke volume variation were observed. Mean cerebral blood flow velocity in the middle cerebral artery did not change during the procedure, but pulsatility index significantly increased. CONCLUSIONS: There is vasoconstriction at the level of the cerebral arterioles in the early phase of experimental sepsis that overwhelmes autoregulatory response. These results may serve as additional pathophysiological information on the cerebral hemodynamic changes occurring during the septic process and may contribute to a better understanding of the pathomechanism of septic encephalopathy.


Assuntos
Circulação Cerebrovascular/fisiologia , Escherichia coli/patogenicidade , Sepse/microbiologia , Sepse/fisiopatologia , Animais , Feminino , Hemodinâmica , Distribuição Aleatória , Suínos , Ultrassonografia Doppler Transcraniana
12.
Infection ; 43(6): 723-7, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26259643

RESUMO

PURPOSE: Fungal infections present a constant risk to critically ill and immunocompromised patients. Therefore, treatment guidelines recommend echinocandins as first-line antifungals in critically ill patients to improve patient outcomes. Echinocandins are usually well tolerated; nevertheless, rare adverse events can occur. There are reports of temporary deterioration of hemodynamic parameters during loading doses, especially in critically ill patients. The objective of this study is to analyze the hemodynamic changes during administration of the echinocandin antifungals, caspofungin and anidulafungin, in medical intensive care unit patients. METHODS: A prospective study in medical ICU patients receiving echinocandins was monitored using single-indicator transpulmonary thermodilution (TPTD). TPTD measurements were performed immediately before, directly after, and 4 h after echinocandins on two following days. RESULTS: Mean arterial pressure and also diastolic blood pressure showed significant changes (p < 0.042 and p < 0.007) after echinocandin application in the measurement immediately after application, but not after 4 h. Basic hemodynamic parameters as well as the TPTD-derived cardiac function parameters did not significantly change after echinocandin application at all. In patients with the need for norepinephrine therapy, the vasopressor dose was not statistically significantly altered. CONCLUSION: To conclude, administration of echinocandins in this observed study population is safe, even in severely critically ill patients if application rules of these agents are followed. However, adverse effects could be observed and practitioners should be cognizant of these effects. These observations can be optimized by high-level assessments, such as the pulse contour cardiac output monitoring, and clinicians should continue to be vigilant with cardiac monitoring of patients receiving echinocandin antifungals.


Assuntos
Antifúngicos/administração & dosagem , Antifúngicos/efeitos adversos , Equinocandinas/administração & dosagem , Equinocandinas/efeitos adversos , Hemodinâmica/efeitos dos fármacos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estado Terminal , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Termodiluição , Adulto Jovem
13.
J Clin Med ; 13(8)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38673607

RESUMO

Background: The use of veno-venous extracorporeal membrane oxygenation (vv-ECMO) in acute lung failure has witnessed a notable increase. The PiCCO system is frequently used for advanced hemodynamic monitoring in this cohort. Our study aimed to investigate whether the choice of indicator injection site (jugular vs. femoral) in patients undergoing vv-ECMO therapy affects transpulmonary thermodilution (TPTD) measurements using the PiCCO® device (Pulsion Medical Systems SE, Munich, Germany). Methods: In a retrospective single-center analysis, we compared thermodilution-derived hemodynamic parameters after simultaneous jugular and femoral injections in 28 measurements obtained in two patients with respiratory failure who were undergoing vv-ECMO therapy. Results: Elevated values of the extravascular lung water index (EVLWI), intrathoracic blood volume index (ITBVI) and global end-diastolic volume index (GEDVI) were observed following femoral indicator injection compared to jugular indicator injection (EVLWI: 29.3 ± 10.9 mL/kg vs. 18.3 ± 6.71 mL/kg, p = 0.0003; ITBVI: 2163 ± 631 mL/m2 vs. 806 ± 125 mL/m2, p < 0.0001; GEDVI: 1731 ± 505 mL/m2 vs. 687 ± 141 mL/m2, p < 0.0001). The discrepancy between femoral and jugular measurements exhibited a linear correlation with extracorporeal blood flow (ECBF). Conclusions: In a PiCCO®-derived hemodynamic assessment of patients on vv-ECMO, the femoral indicator injection, as opposed to the jugular injection, resulted in an overestimation of all index parameters. This discrepancy can be attributed to mean transit time (MTt) and downslope time-dependent (DSt) variations in GEDVI and cardiac function index and is correlated with ECBF.

14.
Cureus ; 16(7): e64786, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39156313

RESUMO

Around the world, lung cancer is the leading cause of cancer-related death and the most commonly diagnosed cancer. In the early stages, surgery is the preferable therapeutic strategy. We present the case of a male patient aged 49 years diagnosed with non-small cell lung cancer of the left lower lobe who was referred for a radical left pneumonectomy. After careful preoperative preparation, the surgery was proceeded with. During the surgery, the patient needed bronchoscopy for the aspiration of the trachea and bronchial tree; after the aspiration procedure, an intraoperative massive hemorrhage started, with shock and ventricular tachycardia. Nine days after surgery, the patient developed a pulmonary embolism and returned to the ICU. The patient benefited from transfusion, intrathoracic cardiac compressions, pulse index continuous cardiac output (PiCCO), renal replacement therapy (RRT), anticoagulation, and intensive care. After a complicated clinical course, the patient is discharged, and after more than 18 months, the patient comes regularly for follow-up consultation in good health.

15.
Int Med Case Rep J ; 17: 111-120, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38348428

RESUMO

Hemodynamic instability in patients with clozapine intoxication can indirectly reflect the serum concentration of clozapine.We have described a case of a 32-year-old pregnant woman who developed life-threatening clozapine toxicity at 28 weeks of gestation. The levels of clozapine and norclozapine in the serum were high. We initiated hemoperfusion(HP) and other detoxification therapies to remove the drug. The patient had severely dilated peripheral blood vessels, which led to cardiac symptoms such as fatal hypotension and uncontrollable tachycardia, resulting in very high cardiac output and elevated Central venous oxygen saturation (ScvO2). Pharmacological intervention significantly improved the hemodynamics.In light of our observations in the ongoing case, we posit that evaluating hemodynamic parameters before and after blood detoxification could serve as a valuable means to gauge effectiveness and provide guidance for treatment.

16.
J Pers Med ; 14(3)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38541030

RESUMO

Liver transplantation is the treatment of choice for end-stage liver disease and despite accumulated experience over the years, improved surgical techniques, better immunosuppression and adequate intensive care management, it still represents the greatest challenge for anesthesiologists. The aim of the study was the characterization of the hemodynamic profile of patients with liver cirrhosis undergoing liver transplantation with the help of the PiCCO system during the three surgical stages, the impact of bleeding on hemodynamic status and correlation between the amount of bleeding, lactate levels, severity scores and survival rate and complications. Another focus of this study was the amount of transfused blood products and their impact on postoperative complications. Our study included 70 patients who underwent liver transplantation in our center and were hemodynamically monitored with the PiCCO system. Data were processed using the Python 3.9 programming language. Results: The mean MELD severity score was 18 points. During surgery, significant variations in the hemodynamic parameters occurred. All patients had a decrease in cardiac output in the anhepatic phase, with 50% presenting a decrease of more than 40%. In total, 78% of patients showed a decrease in the global ejection fraction, with a median value of 30%.Overall, 75% of patients had a total blood loss of less than 6000 mL and 31 patients developed immediate postoperative complications with a 50% probability with blood loss exceeding 6500 mL. Seven patients (10%) did not survive after 30 days. An amount of 5 mmol/L of serum neohepatic lactate determines a 50% probability of complications. Conclusions: Surgical technique causes an important decrease in cardiac output. Intraoperative bleeding has a major impact on outcome and the first month represents a critical period after liver transplantation. Statistical tests describe the probability of 30/90-day survival and the occurrence of complications according to variables such as intraoperative bleeding and MELD severity score. Intraoperative transfusion correlates with the occurrence of postoperative complications.

17.
Front Psychol ; 14: 1186567, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37519364

RESUMO

Organizational climate and job satisfaction have been established as fundamental pillars of research and practice in organizational behavior and organizational psychology, inspiring many explanations and operationalizations over time. In most sectors, global trends such as labor shortages, high rates of turnover and absenteeism, the need to increase productivity, and the interest in new work models concur to keep climate and job satisfaction on top of the research agenda. The situation is particularly acute in the healthcare sector, where related factors have the capacity to influence all aspects of care provision, including patient safety and the physical and mental health of care providers. Nevertheless, a gap in knowledge persists regarding climate, job satisfaction, and their relationships in healthcare services. This protocol describes a study that aims to examine the dynamics of climate and job satisfaction in healthcare organizations from the practice and research perspectives. The protocol complies with PRISMA-P. PRISMA will be used to report the results of the study. Databases will be searched for published studies in May 2023, and we expect to complete the study by December 2024. A framework based on a multi-dimensional concept of quality in research will be used to examine the quality of any studies before inclusion. The results will be disseminated in two systematic reviews. We will describe proposed models depicting the dynamics of climate and job satisfaction in healthcare organizations. We will systematize and discuss available evidence regarding the outcomes of climate and job satisfaction in healthcare work environments. We will synthesize information on research designs and methodological options of included studies. We will identify measures of climate and job satisfaction used in healthcare settings, assess their psychometric properties, and appraise the overall quality of underlying studies. Finally, we expect to identify areas in need of further research.

18.
J Clin Med ; 10(14)2021 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-34300338

RESUMO

Cardiac output monitoring is a common practice in critically ill patients. The PiCCO (pulse index continuous cardiac output) method requires artery cannulation. According to the manufacturer, the cannula in the radial artery should be removed after three days. However, longer monitoring is sometimes necessary. The aim of this study was to assess the incidence of radial artery occlusion (RAO) after three days of cannulation and to check whether five-day cannulation is related to a higher occlusion rate. An additional assessment was made to verify the presence of occlusion three, fourteen and thirty days after decannulation. The PiCCO cannula was inserted into the radial artery after the Barbeau test and Doppler assessment of blood flow. It was left for three or five days. Doppler was performed immediately after its removal and at three, fourteen and thirty days following decannulation. Thirty-seven patients were randomly assigned for three or five days of cannulation, and twenty-three of them were eligible for further analysis. RAO was found in thirteen (56.5%) patients. No statistical difference was found between the RAO rate for three and five day cannulations (p = 0.402). The incidence of RAO was lower when the right radial artery was cannulated (p = 0.022; OR 0.129). Radial artery cannulation with a PiCCO catheter poses a risk of RAO. However, the incidence of prolonged cannulation appeared to not increase the risk of artery occlusion. ClinicalTrials.gov ID NCT02695407.

19.
Int J Gen Med ; 14: 9647-9655, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34934341

RESUMO

OBJECTIVE: To observe hemodynamic characteristics in a series of patients with myocardial injury caused by severe COVID-19-related pneumonia. MATERIALS AND METHODS: We continuously collected clinical data from severe COVID-19-related pneumonia patients from the West Campus of Union Hospital in Wuhan and Dongguan People's Hospital in Dongguan to explore the prevalence of myocardial injury and hemodynamic characteristics after circulatory failure. Doppler ultrasound and PiCCO2 were used to evaluate the hemodynamics of each patient, and arterial blood gas analysis was performed at the same time. Pearson correlation analysis was used to clarify the relationship between the parameters. RESULTS: A total of 376 patients were observed during the study period. Eighty-seven patients had myocardial injury after admission, and the mean time of myocardial injury after admission was 6 (2, 30) days, from which 16 patients developed hemodynamic instability and 15 died of cardiogenic shock or combined with MODS. Cardiac echocardiography found that the LVEF of all patients was in the normal range and that diastolic function was slightly to moderately impaired. The PiCCO2 data showed that the GEF was significantly decreased in all patients. The dpmx was in normal range. EVLWI, SVRI and GEDI were significantly increased in most patients. Pearson correlation analysis showed that cTNI was significantly related to BNP at hemodynamic instability (r = 0.662, p = 0.005); GEF was related to EVLWI (r = -0.572, p = 0.021) and LAC (r = 0.692, p = 0.003); and EVLWI was affected by LVEF (r = -0.564, p = 0.023), LVDF (r = -0.734, p = 0.001) and PVPI (r = -0.524, p = 0.037). CONCLUSION: Hemodynamic status after myocardial injury and cardiogenic shock caused by severe COVID-19-related pneumonia was characterized by cardiac preload and increased EVLWI, accompanied by a decline in GEF.

20.
Ann Intensive Care ; 11(1): 176, 2021 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-34914011

RESUMO

BACKGROUND: Fluid management in patients after subarachnoid hemorrhage (SAH) aims at the optimization of cerebral blood flow and brain oxygenation. In this study, we investigated the effects of hemodynamic management on brain oxygenation by integrating advanced hemodynamic and invasive neuromonitoring. METHODS: This observational cohort bi-center study included data of consecutive poor-grade SAH patients who underwent pulse contour cardiac output (PiCCO) monitoring and invasive neuromonitoring. Fluid management was guided by the transpulmonary thermodilution system and aimed at euvolemia (cardiac index, CI ≥ 3.0 L/min/m2; global end-diastolic index, GEDI 680-800 mL/m2; stroke volume variation, SVV < 10%). Patients were managed using a brain tissue oxygenation (PbtO2) targeted protocol to prevent brain tissue hypoxia (BTH, PbtO2 < 20 mmHg). To assess the association between CI and PbtO2 and the effect of fluid challenges on CI and PbtO2, we used generalized estimating equations to account for repeated measurements. RESULTS: Among a total of 60 included patients (median age 56 [IQRs 47-65] years), BTH occurred in 23% of  the monitoring time during the first 10 days since admission. Overall, mean CI was within normal ranges (ranging from 3.1 ± 1.3 on day 0 to 4.1 ± 1.1 L/min/m2 on day 4). Higher CI levels were associated with higher PbtO2 levels (Wald = 14.2; p < 0.001). Neither daily fluid input nor fluid balance was associated with absolute PbtO2 levels (p = 0.94 and p = 0.85, respectively) or the occurrence of BTH (p = 0.68 and p = 0.71, respectively). PbtO2 levels were not significantly different in preload dependent patients compared to episodes of euvolemia. PbtO2 increased as a response to fluid boluses only if BTH was present at baseline (from 13 ± 6 to 16 ± 11 mmHg, OR = 13.3 [95% CI 2.6-67.4], p = 0.002), but not when all boluses were considered (p = 0.154). CONCLUSIONS: In this study a moderate association between increased cardiac output and brain oxygenation was observed. Fluid challenges may improve PbtO2 only in the presence of baseline BTH. Individualized hemodynamic management requires advanced cardiac and brain monitoring in critically ill SAH patients.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa