Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 382
Filtrar
1.
Curr Allergy Asthma Rep ; 24(6): 317-322, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38776041

RESUMO

PURPOSE OF REVIEW: This review aims to deliver a comprehensive report of the most recent knowledge on diagnosing allergic dermatoses in skin of color (SOC) patients. RECENT FINDINGS: Allergic dermatoses can affect populations of all backgrounds. However, racial/ethnic variations in epidemiology, clinical features, and associated allergens have been reported. Nuances in the approach to diagnosis, including the assessment of erythema and interpretation of patch tests, are important considerations when treating patients with SOC. In this review, we outline various manifestations of allergic dermatoses in SOC with a focus on important clinical presentations and diagnostic tools, aiming to support clinicians in accurate recognition of diseases, thereby opening avenues to improve outcomes across diverse skin types.


Assuntos
Hipersensibilidade , Dermatopatias , Humanos , Alérgenos/imunologia , Hipersensibilidade/diagnóstico , Hipersensibilidade/imunologia , Testes do Emplastro , Pele/patologia , Pele/imunologia , Dermatopatias/diagnóstico , Grupos Raciais
2.
J Am Acad Dermatol ; 90(2): 319-327, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37879460

RESUMO

BACKGROUND: Isothiazolinones are a common cause of allergic contact dermatitis. OBJECTIVE: To examine the prevalence of positive patch test reactions to isothiazolinones from 2017-2020 and characterize isothiazolinone-allergic (Is+) patients compared with isothiazolinone nonallergic (Is-) patients. METHODS: Retrospective cross-sectional analysis of 9028 patients patch tested to methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI) 0.02% aqueous, MI 0.2% aqueous, benzisothiazolinone (BIT) 0.1% petrolatum, and/or octylisothiazolinone (OIT) 0.025% petrolatum. Prevalence, reaction strength, concurrent reactions, clinical relevance, and source of allergens were tabulated. RESULTS: In total, 21.9% (1976/9028) of patients had a positive reaction to 1 or more isothiazolinones. Positivity to MI was 14.4% (1296/9012), MCI/MI was 10.0% (903/9017), BIT was 8.6% (777/9018), and OIT was 05% (49/9028). Compared with Is-, Is+ patients were more likely to have occupational skin disease (16.5% vs 10.3%, P <.001), primary hand dermatitis (30.2% vs 19.7%, P <.001), and be >40 years (73.1% vs 61.9%, P <.001). Positive patch test reactions to >1 isothiazolinone occurred in 44.1% (871/1976) of Is+ patients. Testing solely to MCI/MI would miss 47.3% (611/1292) of MI and 60.1% (466/776) of BIT allergic reactions. LIMITATIONS: Retrospective cross-sectional study design and lack of follow-up data. CONCLUSION: Sensitization to isothiazolinones is high and concurrent sensitization to multiple isothiazolinone allergens is common.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Tiazóis , Humanos , Estudos Transversais , Estudos Retrospectivos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Dermatite Ocupacional/diagnóstico , Dermatite Ocupacional/epidemiologia , Dermatite Ocupacional/etiologia , Alérgenos/efeitos adversos , América do Norte , Testes do Emplastro/efeitos adversos , Vaselina , Conservantes Farmacêuticos/efeitos adversos
3.
J Am Acad Dermatol ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38972480

RESUMO

BACKGROUND: Patch testing to multiple cross reactive allergens for allergic contact dermatitis (ACD) may not be necessary due to copositivity. OBJECTIVE: We evaluated the formaldehyde group allergens to determine the optimal, most cost-effective allergens to test. METHODS: A retrospective analysis of Mayo Clinic (1997-2022) examined the well-established copositive formaldehyde group: Formaldehyde, Quaternium 15, Hexahydro-1,3,5-tris(2-hydroxyethyl)triazine, Diazolidinyl urea, Imidazolidinyl urea, Toluenesulphonamide formaldehyde resin, DMDM hydantoin, and Ethyleneurea melamine formaldehyde mix. Patch Optimization Platform (POP) identified which single formaldehyde-related allergen optimally captures patients with clinically relevant ACD. Next, POP determined the optimal additional 1, 2, 3, etc. allergens. Cost per patch test was $5.19 (Medicare 2022). RESULTS: 9832 patients were tested to all listed allergens, with 830 having positive patch tests. POP determined that Quaternium 15 alone captures 53% of patients with ACD to the formaldehyde group; adding the optimal second allergen (Formaldehyde 1%) captures 78%; the optimal five top allergens capture over 94% of patients. The incremental cost-per-additional-diagnosis increased up to 44-fold as the number of allergens tested increased. LIMITATIONS: Data is from a single institution, and the cost-per-test was fixed to Medicare Part B in 2022. CONCLUSIONS: For diagnosing ACD, we recommend considering an optimized allergen selection algorithm.

4.
Contact Dermatitis ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831517

RESUMO

BACKGROUND: Machine learning (ML) offers an opportunity in contact dermatitis (CD) research, where with full clinical picture, may support diagnosis and patch test accuracy. OBJECTIVE: This review aims to summarise the existing literature on how ML can be applied to CD in its entirety. METHODS: Embase, Medline, IEEE Xplore, and ACM Digital Library were searched from inception to February 7, 2024, for primary literature reporting on ML models in CD. RESULTS: 7834 articles were identified in the search, with 110 moving to full-text review, and six articles included. Two used ML to identify key biomarkers to help distinguish between allergic contact dermatitis (ACD) and irritant contact dermatitis (ICD), three used image data to distinguish between ACD and ICD, and one used clinical and demographical data to predict the risk of positive patch tests. All studies used supervision in their ML model training with a total of 49 704 patients across all data sets. There was sparse reporting of the accuracy of these models. CONCLUSIONS: Although the available research is still limited, there is evidence to suggest that ML has potential to support diagnostic outcomes in a clinical setting. Further research on the use of ML in clinical practice is recommended.

5.
Contact Dermatitis ; 90(3): 201-210, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38148670

RESUMO

After almost three-quarters of a century during which contact dermatologists have often struggled to comprehend the relationship between metal allergy and failure of metal-alloy containing implant, it is possible to say that a relationship does exist, particularly for cobalt and chromium, but also for nickel. There is still debate as to whether allergy develops as a consequent of failure but thenceforth contributes to it, or whether sensitisation starts first and induces failure secondarily-opinion probably favours the first. Metal-on-polypropylene articulations were associated with few metal allergic problems but now are less favoured by orthopaedists due to plastic wear products causing osteolysis and pseudotumour formation through local inflammation. New metal alloys are regularly being introduced such that interested dermatologists need to stay on top of the situation. The jury is still out as to whether the recent favouring of titanium-containing alloys will confirm them to be more inert allergenically. Case reports do show some clinical reactions to titanium-containing implants and patch test series have inferred sometimes quite a high background rate of allergy, but interpretation must be tempered by the awareness that titanium salts on patch testing have a tendency to cause irritant reactions. Blood monitoring of metal ion values is now recommended in certain situations after joint replacement and increasing levels may be an indication that allergy with joint failure can develop, in which case patch testing is indicated, and suggested series are available. Predictive patch testing, whilst generally not recommended in the past, has been introduced into some protocols often by non-dermatologists, such that it is now needed for temporo-mandibular joint and Nuss bar insertion, and it can be anticipated that this may become more commonplace in the future. One of the major current deficits for patch testers is standardised guidance on which preparation or preparations to use for suspected titanium allergy. One suggestion is 0.5% titanium sulphate in petrolatum, though experience in at least one centre suggests the use of a battery of titanium salts might be desirable.


Assuntos
Dermatite Alérgica de Contato , Hipersensibilidade , Humanos , Titânio/efeitos adversos , Sais , Dermatite Alérgica de Contato/complicações , Ligas/efeitos adversos , Metais , Hipersensibilidade/etiologia
6.
Contact Dermatitis ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38778718

RESUMO

BACKGROUND: Earlier studies suggested a potential association between tobacco smoking and nickel sensitization, but little is known about other contact allergens. OBJECTIVES: To investigate the association of smoking status and contact sensitizations as well as subtypes of dermatitis, and to analyse the sensitization profiles of tobacco smokers. PATIENTS AND METHODS: Within the Information Network of Departments of Dermatology (IVDK), we performed a cross-sectional multicentre pilot study comprising 1091 patch-tested patients from 9 departments, comparing 541 patients with a history of cigarette smoking (281 current and 260 former smokers) with 550 never-smokers. RESULTS: We could not confirm the previously reported association between nickel sensitization and tobacco smoking. Moreover, sensitizations to other allergens, including colophony, fragrance mix I, Myroxylon pereirae and formaldehyde, were not increased in cigarette smokers compared with never smokers. Hand dermatitis (50.6% vs. 33.6%) and occupational cause (36.2% vs. 22.5%) were significantly more frequent among cigarette smokers compared with never-smokers as shown by non-overlapping 95% confidence intervals. CONCLUSIONS: Although our study does not allow a firm conclusion on whether smoking status contributes to certain contact sensitizations, it confirms an association of smoking with hand dermatitis and occupational cause.

7.
Contact Dermatitis ; 90(6): 574-584, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38501375

RESUMO

BACKGROUND: Professional ice hockey players may contract irritant and allergic contact dermatitis. AIMS: To investigate the presence of contact allergy (CA) in professional ice hockey players in Sweden. METHODS: Ten teams from the two top leagues were assessed for potential occupational exposure to sensitizers. Exactly 107 players were patch tested with an extended baseline series and a working series, in total 74 test preparations. The CA rates were compared between the ice hockey players and controls from the general population and dermatitis patients. RESULTS: One out of 4 players had at least one contact allergy. The most common sensitizers were Amerchol L 101, nickel and oxidized limonene. CA was as common in the ice hockey players as in dermatitis patients and significantly more common than in the general population. Fragrances and combined sensitizers in cosmetic products (fragrances + preservatives + emulsifier) were significantly more common in ice hockey players compared with the general population. CONCLUSION: The possible relationship between CA to fragrances and cosmetic products on the one hand and the presence of dermatitis on the other should be explored further.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Hóquei , Testes do Emplastro , Humanos , Suécia/epidemiologia , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/diagnóstico , Adulto , Masculino , Dermatite Ocupacional/etiologia , Dermatite Ocupacional/epidemiologia , Níquel/efeitos adversos , Adulto Jovem , Exposição Ocupacional/efeitos adversos , Cosméticos/efeitos adversos , Perfumes/efeitos adversos , Estudos de Casos e Controles , Pessoa de Meia-Idade , Limoneno/efeitos adversos
8.
Contact Dermatitis ; 90(1): 79-83, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37840237

RESUMO

BACKGROUND: Simultaneous overrepresentations of contact allergies and photocontact allergies are common in individuals with photocontact allergy to ketoprofen. AIMS: To investigate whether contact allergy to oxidised (ox.) geraniol, geraniol, geranial, neral and citral is overrepresented in individuals with photocontact allergy to ketoprofen. METHODS: The contact allergy rates to ox. geraniol, geraniol, geranial, neral and citral in routinely patch tested dermatitis patients were compared with the corresponding rates in individuals with photocontact allergy to ketoprofen. RESULTS: Allergic patch test reactions were noted to ox. geraniol 11% (n = 39, 5.8%), ox. geraniol 6% (n = 12, 1.8%), geraniol 6% (n = 2, 0.3%), geranial (n = 18, 2.7%), neral (n = 7, 1.0%) and citral (n = 15, 2.2%). In those four patients who were diagnosed with photocontact allergy to ketoprofen during the test period, a significant overrepresentation (p = 0.020) of simultaneous contact allergy to ox. geraniol 11% was demonstrated. Overrepresentation of simultaneous contact allergy to various combinations of ox. geraniol, ox. limonene and ox. linalool was also noted in ketoprofen-photoallergic patients. CONCLUSIONS: Contact allergy to ox. geraniol, geranial and citral is common in routinely tested dermatitis patients. There is an overrepresentation of simultaneous contact allergy to ox. geraniol, ox. limonene and ox. linalool in patients with photocontact allergy to ketoprofen.


Assuntos
Dermatite Alérgica de Contato , Dermatite Fotoalérgica , Cetoprofeno , Humanos , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/diagnóstico , Cetoprofeno/efeitos adversos , Limoneno , Dermatite Fotoalérgica/epidemiologia , Dermatite Fotoalérgica/etiologia , Testes do Emplastro
9.
Contact Dermatitis ; 90(5): 470-478, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38146081

RESUMO

BACKGROUND: EU Commission Regulation 2017/1410 prohibits using atranol and chloroatranol, the main allergens in Evernia prunastri (oakmoss), and hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) in cosmetic products. Oakmoss absolute is contained in fragrance mix (FM) I and HICC in FM II which are patch tested as screening mixtures in the baseline series. OBJECTIVE: To describe the time trends of reaction frequencies to both FMs as well as to their components in FM-positive patients. METHODS: Retrospective analysis of data from the Information Network of Departments of Dermatology (IVDK), 2012-2021. RESULTS: Positive reactions to FM I (FM II) declined from 9.1% (4.7%) in 2012 to 4.6% (3.0%) in 2021. Full breakdown tests were performed in 24% (FM I) and 31% (FM II), respectively, of the mix-positive patients. From this data, frequencies of sensitization to the 14 single fragrances of FM I and FM II were calculated. For the majority, a decline was noted from 2012/2013 to 2020/2021, for oakmoss absolute 1.9%-0.8% and for HICC 1.8%-0.9%. CONCLUSION: EU Commission Regulation 2017/1410 was an effective measure. However, our data have some limitations, possibly causing underestimation of sensitization frequencies to fragrances.


Assuntos
Aldeídos , Cicloexenos , Dermatite Alérgica de Contato , Perfumes , Resinas Vegetais , Terpenos , Humanos , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/diagnóstico , Odorantes , Estudos Retrospectivos , Testes do Emplastro/efeitos adversos , Alérgenos/efeitos adversos , Perfumes/efeitos adversos
10.
Australas J Dermatol ; 2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38706204

RESUMO

BACKGROUND/OBJECTIVES: In the last 10 years methylisothiazolinone (MI) emerged as a global cause of preservative-related ACD. New Zealand has liberal regulations for the MI concentration limit in cosmetic products compared to Europe and Australia. The aim of this study was to evaluate the prevalence of MI sensitisation in New Zealand, explore sources of MI exposure and make recommendations on New Zealand regulations for MI use. METHODS: This retrospective study included data from patients who underwent patch testing with MI from 2008 to 2021 in a tertiary hospital dermatology clinic and a private dermatology clinic in Auckland, New Zealand. Patient baseline characteristics were recorded along with results of patch testing. Sources of MI exposure were identified from medical records. RESULTS: Over the study period, 1049 patch tests were performed in 1044 patients. MI was only tested as a stand-alone allergen from 2015; positive reactions to MI increased from 5.3% in 2015 to a peak of 11.9% in 2017 and then decreased to 6.4% in 2021. The most common source of MI exposure was shampoo or conditioner (27.7% of all relevant reactions) followed by occupational exposures to paints, biocides or glue (19.1%). CONCLUSION: Both sensitisation and ACD to MI appear to be decreasing, likely secondary to changes in product compounding due to stricter concentration limits internationally. We recommend New Zealand adopt lower MI concentration limits for cosmetics to match the limits of Australia and Europe.

11.
Artigo em Inglês | MEDLINE | ID: mdl-38376473

RESUMO

Summary: Background. Patch testing (PT) is used to identify substances that cause allergic contact dermatitis (ACD). However, the clinical effects of allergen restrictions following PT have not been thoroughly investigated. This study aims to assess the diagnostic accuracy of PT in patients suspected of having ACD. Methods. Prospective study. PT were performed in patients with clinical diagnosis of ACD. Patients with a positive PT (case group) had a strict restriction of the suspected substance for one month. In patients with negative patch testing (control group), allergen restriction was based in clinical history. Clinical reduction (CR) of at least 50% in disease activity (CR50%) after one month of allergen restriction was considered clinically relevant. Total control was defined as clinical reduction of at least 90% (CR90%). Results. From 400 patients, 66.2% had a positive PT. The sensitivity of PT to identify CR50% was 84%, specificity 47%, PPV 53%, and NPV 81%. Only 10.5% of patients achieved CR90%. Conclusions. The PT had moderate diagnostic accuracy. It could be useful as a screening, but a positive result should be confirmed with controlled allergen restriction. The low number of patients who achieved a 90% CR invites to reconsider the allergens included in PT and the mechanistic processes of the disease.

12.
Actas Dermosifiliogr ; 115(7): 712-721, 2024.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38556197

RESUMO

After the meeting held by the Spanish Contact Dermatitis and Skin Allergy Research Group (GEIDAC) back in October 2021, changes were suggested to the Spanish standard series patch testing. Hydroxyethyl methacrylate (2% pet.), textile dye mixt (6.6% pet.), linalool hydroperoxide (1% pet.), and limonene hydroperoxide (0.3% pet.) were, then, added to the series that agreed upon in 2016. Ethyldiamine and phenoxyethanol were excluded. Methyldibromoglutaronitrile, the mixture of sesquiterpene lactones, and hydroxyisohexyl 3-cyclohexene (Lyral) were alo added to the extended Spanish series of 2022.


Assuntos
Dermatite Alérgica de Contato , Testes do Emplastro , Humanos , Espanha , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Alérgenos/efeitos adversos
13.
J Am Acad Dermatol ; 89(5): 1007-1014, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37768237

RESUMO

BACKGROUND: As both allergic contact dermatitis and atopic dermatitis (AD) have similar clinical presentations and are characterized by spongiotic dermatitis on skin biopsy, many children with AD are not referred for patch testing and allergic contact dermatitis is underdiagnosed. OBJECTIVE: To provide updated prevalence data of common contact allergens in children with and without AD. METHODS: This is a retrospective case-control study using the Pediatric Allergic Contact Dermatitis Registry from 2018 to 2022. RESULTS: A total of 912 children were included (615 with AD and 297 without AD). Children with AD were more likely to have a longer history of dermatitis (4.1 vs 1.6 years, P < .0001), have seen more providers (2.3 vs 2.1, P = .003), have greater than 1 positive patch test (PPT) result (P = .005), have a greater number of PPT results overall (2.3 vs 1.9, P = .012), and have a more generalized distribution of dermatitis (P = .001). PPT to bacitracin (P = .030), carba mix (P = .025), and cocamidopropyl betaine (P = .0007) were significantly increased in children with AD compared to those without AD. LIMITATIONS: Technical variation between providers and potential for misclassification, selection, and recall biases. CONCLUSION: Children with AD are significantly more likely to have PPT reactions and should be referred for evaluation of allergic contact dermatitis and obtain patch testing.

14.
Contact Dermatitis ; 88(4): 249-262, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36458568

RESUMO

Vulvar allergic contact dermatitis (vACD) and irritant contact dermatitis (vICD) are common and accompanied by a great burden on the patient's life. We aimed to review the existing literature on vACD and vICD in order to provide a comprehensive reference list of potential vulvar allergens and irritants, as well as to establish the role of patch testing therein. A systematic search was performed in Medline, Embase and Web of Science using a search string based on the PICO-format. The study protocol was registered at PROSPERO (CRD42021239527). Multiple allergens were identified and included metals, topical drugs, fragrances, preservatives, cosmetic constituents and rubber components. Not all positive reactions were, however, considered to be relevant. Patch testing is the primary tool for the identification of the causal allergens. Testing with standard series alone was proven to be insufficient. Little information about irritants was found. In the future, additional series and late readings should be considered in standard practice. Studies on vICD are scarce and further research is necessary. More population-based research should be performed.


Assuntos
Dermatite Alérgica de Contato , Dermatite Irritante , Feminino , Humanos , Alérgenos , Irritantes , Dermatite Alérgica de Contato/etiologia , Testes do Emplastro/métodos , Dermatite Irritante/etiologia , Vulva
15.
Contact Dermatitis ; 88(3): 220-229, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36461774

RESUMO

BACKGROUND: Textile dye mix (TDM) is included in the European baseline series (EBS), but it is unknown if TDM identifies all patients with a textile dye allergy. OBJECTIVES: To assess the added value of performing patch testing with individual textile dyes in addition to TDM. METHODS: Two hundred and nine patients suspected to have a contact allergy to textile dyes were patch tested between January 2015 and December 2021 with the EBS, as well as an individual textile dye test series containing textile dyes part of TDM (TDM-dyes) and outside the scope of TDM (non-TDM dyes). RESULTS: Fifty-four patients (25.8%) tested positive for TDM or an individual textile dye. Disperse Orange 3 (9.6%) followed by Disperse Blue 106 (4.8%) were the most common individual textile dyes causing a positive patch test reaction. Of the 54 dye positive patients, 28 (51.9%) had a clinically relevant reaction. No clinically relevant reactions were seen in patients that solely tested positive for non-TDM dyes. CONCLUSIONS: It is beneficial to test individual textile dyes in addition to TDM in patients suspected of having a textile dye allergy. Otherwise, 46.3% of the dye positive patients and 35.7% of the patients with a clinically relevant reaction would have been missed.


Assuntos
Dermatite Alérgica de Contato , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Testes do Emplastro/efeitos adversos , Prevalência , Têxteis/efeitos adversos , Corantes/efeitos adversos , Alérgenos/efeitos adversos
16.
Contact Dermatitis ; 88(1): 54-59, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36112512

RESUMO

BACKGROUND: The textile dye mix (TDM) 6.6% in petrolatum contains Disperse Blue (DB) 35, Disperse Yellow 3, Disperse Orange (DO) 1 and 3, Disperse Red 1 and 17, and DB 106 and 124. The most frequent allergen in TDM-positive patients is DO 3. Around 85% of para-phenylenediamine (PPD)-allergic dermatitis patients have been positive to DO 3. There has been a discussion to exclude DO 3 from TDM 6.6% because of strong simultaneous reactions to TDM and PPD. OBJECTIVES: To study if DO 3 can be excluded from TDM 6.6%. METHODS: Patch tests were performed on 1481 dermatitis patients with TDM 6.6%, TDM 7.0% (without DO 3 but the other disperse dyes at 1.0% each), DO 3 1.0%, and PPD 1.0% pet. RESULTS: Contact allergy to TDM 6.6% was 3.6% and to TDM 7.0% was 3.0%. All 26 DO 3-positive patients were positive to PPD. The 44 patients positive to TDM 7.0% plus the 13 positive to PPD and TDM 6.6% but negative to TDM 7.0% were 57, outnumbering the 53 positive to TDM 6.6%. CONCLUSION: TDM 7.0% can replace TDM 6.6% in the Swedish baseline series, since TDM 7.0% together with PPD 1.0% will detect patients with textile dye allergy.


Assuntos
Dermatite Alérgica de Contato , Humanos , Testes do Emplastro/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Suécia , Têxteis/efeitos adversos , Corantes/efeitos adversos
17.
Contact Dermatitis ; 89(3): 153-160, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37271726

RESUMO

BACKGROUND: It is known that a large number of hairdressing apprentices (HA) develop occupational contact dermatitis (OCD) during schooling, but studies that address prevalence of contact sensitization in HAs with hand eczema are missing. OBJECTIVES: To assess the prevalence, incidence rate and clinical characteristics of OCD, including contact sensitization, in a sample of Croatian HAs. MATERIALS AND METHODS: A total of 408 HAs from 25 Croatian towns were examined at the beginning of education and monitored at the end of each school year. Clinical evaluation of skin changes was performed using the Osnabrueck Hand Eczema Severity Index (OHSI). Standard patch test (PT) with baseline and hairdresser series of contact allergens was performed in 46 HAs with skin changes lasting ≥3 months. RESULTS: The overall incidence rate of OCD was 32.3/100 person-years, and the 3-year prevalence 50.3%. Contact sensitization was found in 14 out of 46 (30.3%) HAs, with 10 of these 14 HAs (71.4%) sensitized to specific hairdressing allergens. The strongest reactions were found to PPD. HAs with positive PT had higher OHSI than HAs with negative patch test (median, IQR: 3, 2-4 vs. 2, 2-4). CONCLUSIONS: Contact sensitization to specific hairdressing chemicals was found in 71.4% of HAs with a positive patch test, supporting evidence on the early contact sensitization to occupational allergens among HAs.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Eczema , Humanos , Incidência , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Estudos Prospectivos , Prevalência , Dermatite Ocupacional/etiologia , Dermatite Ocupacional/complicações , Alérgenos/efeitos adversos , Eczema/epidemiologia , Testes do Emplastro/efeitos adversos
18.
Contact Dermatitis ; 88(6): 472-479, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36975130

RESUMO

BACKGROUND: The two dialkylthiocarbamyl benzothiazole sulphides, dimethyl-thiocarbamylbenzothiazole sulphide (DMTBS) and diethylthio-carbamylbenzothiazole sulphide (DETBS) were shown to be good markers of both thiuram and mercaptobenzothiazole sensitivity. OBJECTIVES: To investigate if DMTBS and/or DETBS could be better markers of contact allergy to common rubber additives than the ones currently used. METHODS: Sixty-eight dermatitis patients were patch tested with DMTBS and DETBS, both at 1% in petrolatum (pet). Because of late reactions in 10 patients, these were retested to DMTBS and DETBS in serial dilutions. Tetramethylthiuram monosulphide (TMTM) 1.0% pet was also tested. RESULTS: At the initial reading Days 3 and 7, no reactions were noted to DMTBS or DETBS. At retesting, 10 of the 68 (15%) patients reacted positively to lower concentrations of DMTBS than the initial test concentration. Seven of 8 also reacted to TMTM. Three of them had positive reactions to DEBTS. All 10 patients had reactions to more diluted solutions to DMBTS than to DEBTS (p = 0.0077; Mc-Nemar test, two-sided). CONCLUSIONS: Results speak for patch test sensitization to DMTBS with cross-reactivity to TMTM and also DEBTS. DMTBS and DEBTS could be new markers of rubber allergy but a safe test concentration must be found.


Assuntos
Dermatite Alérgica de Contato , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Borracha/efeitos adversos , Alérgenos/efeitos adversos , Testes do Emplastro/efeitos adversos , Sulfetos/efeitos adversos
19.
Contact Dermatitis ; 88(4): 263-274, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36694979

RESUMO

BACKGROUND: Occupational skin diseases have led the occupational disease statistics in Europe for many years. Especially occupational allergic contact dermatitis is associated with a poor prognosis and low healing rates leading to an enormous burden for the affected individual and for society. OBJECTIVES: To present the sensitization frequencies to the most relevant allergens of the European baseline series in patients with occupational contact dermatitis (OCD) and to compare sensitization profiles of different occupations. METHODS: The data of 16 022 patients considered having OCD after patch testing within the European Surveillance System on Contact Allergies (ESSCA) network between January 2011 and December 2020 were evaluated. Patients (n = 46 652) in whom an occupational causation was refuted served as comparison group. RESULTS: The highest percentages of OCD were found among patients working in agriculture, fishery and related workers, metal industry, chemical industry, followed by building and construction industry, health care, food and service industry. Sensitizations to rubber chemicals (thiurams, carbamates, benzothiazoles) and epoxy resins were associated with at least a doubled risk of OCD. After a decline from 2014 onwards, the risks to acquire an occupation-related sensitization to methyl(chloro)isothiazolinone (MCI/MI) and especially to methylisothiazolinone (MI) seem to increase again. Sensitization rates to formaldehyde were stable, and to methyldibromo glutaronitrile (MDBGN) slightly decreasing over time. CONCLUSIONS: Among allergens in the European Baseline Series, occupational relevance is most frequently attributed to rubber accelerators, epoxy resins and preservatives.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Humanos , Dermatite Alérgica de Contato/etiologia , Testes do Emplastro/efeitos adversos , Borracha , Resinas Epóxi , Dermatite Ocupacional/etiologia , Alérgenos , Benzotiazóis
20.
Contact Dermatitis ; 89(2): 79-84, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37100088

RESUMO

BACKGROUND: Propylene glycol (PG) is used in a variety of cosmetics, food and pharmaceuticals. PG is a known sensitizer but also irritating when patch tested (PT). OBJECTIVES: The aims were to investigate the frequency of contact sensitization to PG and to identify cases of allergic contact dermatitis (ACD). METHODS: A retrospective study was performed on patients PT at the Skin Health Institute (SHI), Victoria, Australia to PG 5% pet. and PG 10% aq. between 1 January 2005 and 31 December 2020. RESULTS: In all, 6761 patients were PT to PG and 21 (0.31%) reacted. Of those 21 individuals, 9 (42.9%) had a relevant reaction. 75% of relevant positive reactions were in patients PT to PG 10% aq. The most common source of PG exposure was topical medicaments (77.8% of relevant reactions) and moisturizers, with the largest group being topical corticosteroids. CONCLUSION: Contact sensitization to PG in the patch test population remains uncommon, although it is possible that testing with concentrations of 5%-10% PG did not identify all reactions. Topical corticosteroids were the most important cause. Patients with suspected contact dermatitis to topical corticosteroids should be PT to PG.


Assuntos
Dermatite Alérgica de Contato , Fármacos Dermatológicos , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Estudos Retrospectivos , Propilenoglicol/efeitos adversos , Alérgenos/efeitos adversos , Testes do Emplastro/efeitos adversos , Vitória/epidemiologia , Glucocorticoides/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa