1.
Graefes Arch Clin Exp Ophthalmol ; 262(3): 891-901, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37688609

RESUMO

PURPOSE: To assess the feasibility and reliability of biometric measurements taken with the Eyestar 900 device in keratoconus eyes in comparison with those taken with the Pentacam HR and IOLMaster 700. METHODS: Seventy-five eyes of 75 patients with keratoconus were included. The central corneal thickness (CCT), thinnest point of corneal thickness (TCT), axial length (AL), flat (K1) and steep (K2) anterior and posterior (Kp1, Kp2) keratometry, maximal keratometry (KMax) and anterior chamber depth (ACD) were compared between the Eyestar 900, Pentacam HR and IOLMaster 700. Reliability parameters such as the coefficient of variation (CoV) and intraclass correlation coefficient (ICC) were calculated. Pearson's r was determined to assess the correlation between devices. RESULTS: A high repeatability (CoV < 1%) and intraclass correlation (ICC > 0.9) was found for all devices, led by AL, TCT, K1 and K2 (CoV 0.01-0.36%; ICC 0.994-1.00). The largest correlation between devices was found for AL (Eyestar vs. IOLMaster, r = 1.0), K1 (Eyestar vs. IOLMaster, r = 0.997) and ACD (Eyestar vs. IOLMaster, r = 0.995; Pentacam vs. IOLMaster, r = 0.987; Eyestar vs. Pentacam, r = 0.983), but there were significant differences in measured values between devices (p < 0.001), whereas the correlation was only slightly lower (r = 0.947 to 0.994) for KMax, CCT, TCT, K2, Kp1 and Kp2. CONCLUSION: Keratometric and axial length measurements with the Eyestar 900 were feasible and revealed a high repeatability and a good correlation to the other devices in eyes with keratoconus.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Tomografia de Coerência Óptica , Reprodutibilidade dos Testes , Olho , Biometria
2.
Graefes Arch Clin Exp Ophthalmol ; 262(3): 995-996, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37548670

RESUMO

Pupil diameter is a key parameter for corneal and multifocal intraocular lens surgery. Many devices are dedicated to measure the pupil size, but do not specify the illumination during capture. The aim of this study was to present illumination levels in routinely used ophthalmic devices which present pupil sizes. To obtain measurements, the lux meter was placed in the chin rest in the corneal plane and the room was completely dimmed. Ten measurements were taken for each device. The illumination levels for white and red Placido disk corneal topographers were 1253.1 ± 0.2 and 329.0 ± 0.2 lux, respectively (both photopic conditions). Scheimpflug corneal tomography should be considered as a mesopic measurement (14.5 ± 0.1 lux). Optical coherence tomography and autorefractometry are scotopic measurements (0.4-0.6 lux). We postulate that producers should provide illumination levels of their devices measuring pupil size. Moreover, when mentioning a pupil size, one should consider presenting to what lighting conditions it refers to.


Assuntos
Visão de Cores , Lentes Intraoculares Multifocais , Humanos , Iluminação , Córnea , Tomografia de Coerência Óptica
3.
Graefes Arch Clin Exp Ophthalmol ; 262(5): 1567-1578, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38150029

RESUMO

PURPOSE: To assess the differences and similarities in the corneal curvature obtained by two swept-source optical coherence tomography (SS-OCT) devices, Scheimpflug imaging system and one ray tracing aberrometer in patients with cataracts. Moreover, this study aimed to compare the differences in posterior corneal (PK), total corneal (TK) and true net power (TNP) measurements among the IOLMaster 700, CASIA2, and Pentacam. METHODS: A total of 200 eyes of 200 patients (116 female, 58%) were enrolled in this study, with a mean age of 65.9 ± 9.5 years. The flattest (Kf), steepest (Ks), and mean cornal powers (Km), J0, and J45 were obtained using two SS-OCT-based biometric devices, one rotating camera system and one ray-tracing aberrometer. The PK, TK and TNP values were also measured using these devices. To evaluate the differences and similarities between the devicves, the Friedman test, Pearson correlation coefficient (r), intraclass coefficient correlation (ICC) and Bland‒Altman plots with 95% limits of agreement (LoA) were used, and boxplots and stacked histograms were generated to describe the distributions of the data. RESULTS: There were no significant differences between the IOLMaster 700 and Pentacam for any of the keratometry values. Additionally, there were no significant differences between the IOLMaster 700 and iTrace in evaluating J0 and J45. Bland‒Altman plots revealed relatively wide LoA widths, almost larger than 1 diopter for the keratometry values and almost larger than 0.5 diopter for J0 and J45 values among the four devices. In terms of PK and TK values, significant differences and low ICCs were found among the three devices. CONCLUSIONS: Although strong correlations and good agreement were found among the IOLMaster700, CASIA2, Pentacam and iTrace for Kf, Ks, Km and J0, J45, it seems that the measurements should not be used interchangeably because of the wide LoA widths and the presence of significant differences among the devices. Similarly, due to significant differences and low ICCs, the PK, TK and TNP values obtained by IOLMaster 700, CASIA2, and Pentacam should not be used interchangeably.


Assuntos
Catarata , Tomografia de Coerência Óptica , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia de Coerência Óptica/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Córnea , Catarata/diagnóstico , Biometria , Topografia da Córnea/métodos
4.
BMC Ophthalmol ; 24(1): 285, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39009964

RESUMO

AIM: This study aimed to differentiate moderate to high myopic astigmatism from forme fruste keratoconus using Pentacam parameters and develop a predictive model for early keratoconus detection. METHODS: We retrospectively analysed 196 eyes from 105 patients and compared Pentacam variables between myopic astigmatism (156 eyes) and forme fruste keratoconus (40 eyes) groups. Receiver operating characteristic curve analysis was used to determine the optimal cut-off values, and a logistic regression model was used to refine the diagnostic accuracy. RESULTS: Statistically significant differences were observed in most Pentacam variables between the groups (p < 0.05). Parameters such as the Index of Surface Variance (ISV), Keratoconus Index (KI), Belin/Ambrosio Deviation Display (BAD_D) and Back Elevation of the Thinnest Corneal Locale (B.Ele.Th) demonstrated promising discriminatory abilities, with BAD_D exhibiting the highest Area under the Curve. The logistic regression model achieved high sensitivity (92.5%), specificity (96.8%), accuracy (95.9%), and positive predictive value (88.1%). CONCLUSION: The simultaneous evaluation of BAD_D, ISV, B.Ele.Th, and KI aids in identifying forme fruste keratoconus cases. Optimal cut-off points demonstrate acceptable sensitivity and specificity, emphasizing their clinical utility pending further refinement and validation across diverse demographics.


Assuntos
Topografia da Córnea , Ceratocone , Fotografação , Curva ROC , Humanos , Ceratocone/diagnóstico , Feminino , Masculino , Estudos Retrospectivos , Adulto , Gana , Topografia da Córnea/métodos , Fotografação/métodos , Adulto Jovem , Adolescente , Córnea/patologia , Córnea/diagnóstico por imagem , Pessoa de Meia-Idade , Miopia/diagnóstico , Astigmatismo/diagnóstico , Acuidade Visual
5.
BMC Ophthalmol ; 24(1): 410, 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39300358

RESUMO

PURPOSE: To compare the biometric measurements obtained from the Pentacam AXL Wave, IOLMaster 700, and ANTERION and calculate the recommended intraocular lens power using the Barrett Formulae. METHODS: This was a retrospective cross-sectional study of patients who underwent biometry using the Pentacam AXL Wave, IOLMaster 700, and ANTERION. Flat keratometry (K1), steep keratometry (K2), anterior chamber depth (ACD), and axial length (AL) from each device were measured and compared. These parameters were used to calculate the recommended IOL powers using the Barrett formula. RESULTS: The study included 252 eyes of 153 patients. The IOLMaster had the highest acquisition rate among the two biometers. The Pentacam obtained the shortest mean AL, the IOLMaster measured the highest mean keratometry values, and the ANTERION measured the highest mean ACD. In terms of pairwise comparisons, keratometry and axial length were not significantly different between the Pentacam-IOLMaster and ANTERION-IOLMaster groups, while the rest of the pairwise comparisons were statistically significant. In nontoric and toric eyes, 35-45% of patients recommended the same sphere of IOL power. In another 30-40%, the Pentacam and ANTERION recommended an IOL power one step greater than that of the IOLMaster-derived data. 50% of the study population recommended the same toric-cylinder IOL power. CONCLUSIONS: The Pentacam AXL Wave, IOLMaster 700, and ANTERION can reliably provide data for IOL power calculations; however, these data are not interchangeable. In nontoric and toric eyes, 35-45% of cases recommended the same sphere IOL power, and in another 30-40%, the Pentacam and ANTERION recommended one-step higher IOL power than the IOLMaster-derived data. In targeting emmetropia, selecting the first plus IOL power is advisable when using the Pentacam and ANTERION to approximate the IOL power calculations recommended by the IOLMaster 700.


Assuntos
Biometria , Interferometria , Lentes Intraoculares , Tomografia de Coerência Óptica , Humanos , Estudos Retrospectivos , Estudos Transversais , Masculino , Biometria/instrumentação , Biometria/métodos , Feminino , Pessoa de Meia-Idade , Interferometria/instrumentação , Interferometria/métodos , Idoso , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/instrumentação , Comprimento Axial do Olho/diagnóstico por imagem , Adulto , Idoso de 80 Anos ou mais , Refração Ocular/fisiologia , Óptica e Fotônica , Câmara Anterior/diagnóstico por imagem
6.
BMC Ophthalmol ; 24(1): 349, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39152392

RESUMO

BACKGROUND: Accurate prediction of postoperative vault in implantable collamer lens (ICL) implantation is crucial; however, current formulas often fail to account for individual anatomical variations, leading to suboptimal visual outcomes and necessitating improved predictive models. We aimed to verify the prediction accuracy of our new predictive model for vaulting based on anterior and posterior chamber structural parameters. METHODS: This retrospective observational study included 137 patients (240 eyes) who previously underwent ICL surgery. Patients were randomly divided into the model establishment (192 eyes) or validation (48 eyes) groups. Preoperative measurements of the anterior and posterior chamber structures were obtained using Pentacam, CASIA2 anterior segment optical coherence tomography (AS-OCT), ultrasound biomicroscopy, and other devices. Stepwise multiple linear regression analysis was used to evaluate the relationship between the vault and each variable (WL formula). The Friedman test was performed for the vaulting prediction results of the WL, NK (Ver. 3), and KS formulas (Ver. 4) in CASIA2 AS-OCT, as well as the Zhu formula and vault measurements. The proportions of prediction error within ± 250 µm per formula were compared. RESULTS: The predicted vault values of the WL, NK, KS, and Zhu formulas and vault measurements were 668.74 ± 162.12, 650.85 ± 248.47, 546.56 ± 128.99, 486.56 ± 210.76, and 716.06 ± 233.84 µm, respectively, with a significant difference (χ2 = 69.883, P = 0.000). Significant differences were also found between the measured vault value and Zhu formula, measured vault value and KS formula, WL formula and Zhu formula, WL formula and KS formula, NK formula and KS formula, and NK formula and Zhu formula (P < 0.001) but not between other groups. The proportions of prediction error within ± 250 µm per formula were as follows: WL formula (81.3%) > NK formula (70.8%) > KS formula (66.7%) > Zhu formula (54.2%). CONCLUSIONS: The WL formula, which considers the complexity of the anterior and posterior chamber structures, demonstrates greater calculation accuracy, compared with the KS (Ver. 4) and Zhu formulas. The proportion of absolute prediction error ≤ 250 µm is higher with the WL formula than with the NK formula (ver. 3). This enhanced predictive capability can improve ICL sizing decisions, thereby increasing the safety and efficacy of ICL implantation surgeries.


Assuntos
Implante de Lente Intraocular , Tomografia de Coerência Óptica , Humanos , Estudos Retrospectivos , Feminino , Masculino , Tomografia de Coerência Óptica/métodos , Adulto , Implante de Lente Intraocular/métodos , Câmara Anterior/diagnóstico por imagem , Lentes Intraoculares Fácicas , Miopia/cirurgia , Microscopia Acústica/métodos , Adulto Jovem , Pessoa de Meia-Idade , Acuidade Visual , Biometria/métodos , Refração Ocular/fisiologia
7.
Int Ophthalmol ; 44(1): 237, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38902457

RESUMO

PURPOSE: Calculating the intraocular lens (IOL) in patients after corneal refractive surgery presents a challenge. Because an overestimation of corneal power in cases undergone this surgery leading to a subsequent under-correction of IOL power. However, recent advancements in technology have eliable measurement of total corneal power. The aim of this research was to assess the agreement in simulated keratometry (SimK) and total keratometry (TK) values between IOLMaster 700 and Pentacam AXL. METHODS: The study involved 99 patients (99 eyes) undergone small incision lenticule extraction (SMILE) surgery. Each patient underwent scans using IOL Master 700 and Pentacam AXL. The following parameters were recorded: SimK1, SimK2, Total K1 (TK1), and Total K2 (TK2) for IOLMaster 700; and SimK1, SimK2, True Net Power (TNP) K1, TNPK2, Total Corneal Refractive Power (TCRP) K1, and TCRP K2 for Pentacam AXL. Agreement between the two devices was evaluated using Bland-Altman plot, while paired t-test was utilized to compare any differences in the same parameter by both instruments. RESULTS: The results revealed a strong correlation between the two devices.Noticeable comparability was identified for all SimK variables. However, there were noticeable differences in TK measurements as well as TK1-TNPK1, TK2-TNP K2, TK1-TCRP K1, and TK2-TCRP K2 parameters when comparing the two devices. The IOLMaster 700 consistently measured steeper values than the Pentacam AXL, with significant and clinically relevant differences of 1.34, 1.37, 0.87, and 0.95 diopters, respectively. CONCLUSION: While there was a noticeable correlation between the IOLMaster 700 and Pentacam AXL in SimK measurements, a marked difference was noted in TK values. The two devices cannot be used interchangeably when quantifying TK values.


Assuntos
Córnea , Topografia da Córnea , Miopia , Refração Ocular , Humanos , Masculino , Feminino , Adulto , Córnea/cirurgia , Córnea/diagnóstico por imagem , Córnea/patologia , Refração Ocular/fisiologia , Topografia da Córnea/métodos , Miopia/cirurgia , Miopia/diagnóstico , Pessoa de Meia-Idade , Adulto Jovem , Lentes Intraoculares , Biometria/métodos , Biometria/instrumentação , Estudos Prospectivos , Reprodutibilidade dos Testes , Acuidade Visual , Cirurgia da Córnea a Laser/métodos
8.
Vestn Oftalmol ; 140(2. Vyp. 2): 136-142, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739143

RESUMO

Pterygium is a common inflammatory-proliferative disease characterized by the invasion of degeneratively altered fibrovascular tissue into the cornea. This literature review analyzes the etiological factors and pathogenetic concepts of its development, describes modern methods of diagnostics and surgical treatment of pterygium, and pays particular attention to the assessment of structural and functional changes in the cornea occurring during the growth of pterygium and after its excision.


Assuntos
Procedimentos Cirúrgicos Oftalmológicos , Pterígio , Pterígio/diagnóstico , Pterígio/terapia , Pterígio/etiologia , Humanos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Córnea/diagnóstico por imagem , Córnea/patologia , Túnica Conjuntiva/patologia
9.
Graefes Arch Clin Exp Ophthalmol ; 261(11): 3241-3247, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37314521

RESUMO

Keratoconus appears to be a rare corneal disease with a prevalence previously estimated at 1:2000. The aim of our study was to investigate the prevalence of keratoconus in a large German cohort and to evaluate possible associated factors. METHOD: In the population-based, prospective, monocentric cohort study, Gutenberg Health Study, 12,423 subjects aged 40-80 years were examined at the 5-year follow-up. Subjects underwent a detailed medical history and a general and ophthalmologic examination including Scheimpflug imaging. Keratoconus diagnosis was performed in two steps: all subjects with conspicuous TKC analysis of corneal tomography were included in further grading. Prevalence and 95% confidence intervals were calculated. Logistic regression analysis was carried out to investigate association with age, sex, BMI, thyroid hormone, smoking, diabetes, arterial hypertension, atopy, allergy, steroid use, sleep apnea, asthma, and depression. RESULTS: Of 10,419 subjects, 75 eyes of 51 subjects were classified as having keratoconus. The prevalence for keratoconus in the German cohort was 0.49% (1:204; 95% CI: 0.36-0.64%) and was approximately equally distributed across the age decades. No gender predisposition could be demonstrated. Logistic regression showed no association between keratoconus and age, sex, BMI, thyroid hormone, smoking, diabetes, arterial hypertension, atopy, allergy, steroid use, sleep apnea, asthma, and depression in our sample. CONCLUSION: The prevalence of keratoconus disease in a mainly Caucasian population is approximately tenfold higher than previously reported in the literature using latest technologies (Scheimpflug imaging). Contrary to previous assumptions, we did not find associations with sex, existing atopy, thyroid dysfunction, diabetes, smoking, and depression.

10.
BMC Ophthalmol ; 23(1): 201, 2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37150816

RESUMO

BACKGROUND: To investigate whether the repeatability of measurements with the Pentacam HR in patients with keratoconus is improved by patients gaining more experience of the measurement situation. Such an improvement could enhance the accuracy with which progressive keratoconus can be detected. METHODS: Four replicate measurements were performed on Day 0 and on Day 3. Parameters commonly used in the diagnosis of progressive keratoconus were included in the analysis, namely the flattest central keratometry value (K1), the steepest central keratometry value (K2), the maximum keratometry value (Kmax), and the parameters A, B and C from the Belin ABCD Progression Display. In addition, quality parameters used by the Pentacam HR to assess the quality of the measurements were included, namely the analysed area (front + back), 3D (front + back), XY, Z, and eye movements. RESULTS: Neither the diagnostic parameters nor the quality parameters showed any statistically significant improvement on Day 3 compared to Day 0. The quality parameter "eye movements" deteriorated significantly with increasing Kmax. CONCLUSION: Gaining experience of the measurement situation did not increase the accuracy of the measurements. Further investigations should be performed to determine whether the increasing number of eye movements with increasing disease severity has a negative effect on the repeatability of the measurements.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Topografia da Córnea , Paquimetria Corneana , Córnea , Avaliação de Resultados da Assistência ao Paciente
11.
BMC Ophthalmol ; 23(1): 427, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37872473

RESUMO

PURPOSE: The present study was conducted to determine the corneal topographic indices of Scheimpflug camera in type 2 diabetes patients without diabetic retinopathy (DR), DR and non-diabetic elderly populations. METHODS: A total of 1105 participants were selected using random cluster sampling from Tehran, Iran and categorized into three groups including type 2 diabetes patients without diabetic retinopathy (DR), DR and non-diabetic. The diabetic group had HbA1c levels ≥ 6.4% with no other systemic problems. The non-diabetic participants had normal eye findings and no systemic diseases. The pachymetric progression index (PPI) values were measured using the Pentacam AXL. RESULTS: A total of 1105 participants including 429 diabetes patients (38.46% male) and 676 non-diabetic (38.76% male) subjects entered the study. Only PPIavg and PPImax were higher in the diabetics versus non-diabetics (P = 0.019 and 0.010, respectively). There was a significant difference in PPImax between the three groups (P = 0.036). There were significant differences only in index of vertical asymmetry (IVA), central keratoconus index (CKI), PPI average, and PPI max between different stages of diabetic retinopathy (DR) (P = 0.045, 0.005, 0.002, and 0.004, respectively). There was a significant difference in index of Surface Variance (ISV), index of vertical asymmetry (IVA), PPIavg, and PPImax between diabetes patients with and without DR (P = 0.016, 0.022, < 0.001, and < 0.001, respectively). CONCLUSION: According to the results, diabetes and DR change several topographic indices. In addition, the HbA1c level may affect pachymetric progression index max. Therefore, special attention should be paid to these patients for different treatment strategies.


Assuntos
Diabetes Mellitus Tipo 2 , Retinopatia Diabética , Ceratocone , Humanos , Masculino , Idoso , Feminino , Córnea , Retinopatia Diabética/diagnóstico , Diabetes Mellitus Tipo 2/complicações , Hemoglobinas Glicadas , Irã (Geográfico)/epidemiologia , Topografia da Córnea/métodos
12.
BMC Ophthalmol ; 23(1): 448, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37950259

RESUMO

PURPOSE: To investigate the agreement between Pentacam and CASIA2 in the evaluation of corneal densities (CDs) and lens densities (LDs) in myopes. METHODS: Fifty-three patients (106 eyes) underwent comprehensive ophthalmologic examinations. CDs and LDs were measured using Pentacam and CASIA2, respectively, based on the grayscale percentage of the obtained images. Agreement between Pentacam and CASIA2 was evaluated using the consistency intraclass correlation coefficient (ICC) and represented using Bland-Altman plots. RESULTS: Compared to Pentacam, CASIA2 showed significantly higher CD and LD values in all measured zones. The ICC of the average CD and LD measured by the Pentacam and CASIA2 were 0.726 and 0.757, respectively. The ICC values of all corneal zones and lenses were above 0.7, except for the measurement of the cornea in the 0-2 mm zone (0.455), suggesting good consistency between the two devices, whose results were of different levels of linear correlation. Bland-Altman plots showed mean percentages of 3.93% for the points falling outside the limits of agreement among the densitometry results. The ICCs in different age groups were similar, but the agreement was poorer in the high myopia group (low and moderate myopia, CD: 0.739, LD: 0.753; high myopia, CD: 0.621, LD: 0.760). CONCLUSIONS: CASIA2 demonstrated good consistency with Pentacam in the measurement of CD and LD, except for measurement of CD in the central cornea and in high myopia. Despite difference in the numerical results compared with Pentacam, which made the two devices uninterchangeable, CASIA2 provides a reliable alternative densitometric measurement method.


Assuntos
Cristalino , Miopia , Humanos , Córnea , Miopia/diagnóstico
13.
BMC Ophthalmol ; 23(1): 194, 2023 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-37138239

RESUMO

BACKGROUND: Keratoconus (KC) is easily recognized by its unique topographic pattern, but it can be difficult to distinguish subclinical form of the disease from the normal cornea. Optovue anterior segment optical coherence tomography (AS-OCT) helps diagnose KC. AIM OF THE WORK: To assess and the level of agreement of Keratometry-readings (K), Central Corneal Thickness (CCT) and Thinnest Corneal Thickness (TCT) measurements obtained by Optovue AS-OCT and Wavelight Oculyzer Pentacam HR in two groups: KC eyes and normal eyes. PATIENTS AND METHODS: This is a prospective clinical observational study. The study included 110 eyes divided into two groups. The study group included 62 eyes with topographic evidence of KC. The control group included 48 eyes of normal subjects with no topographic evidence of KC. All of the participants underwent full cycloplegic refraction, spectacle best-corrected distance visual acuity, comprehensive slit-lamp biomicroscopy and fundoscopy. All participants underwent corneal topography by Pentacam HR and AS-OCT. RESULTS: There were highly significant differences between the studied groups as regarding BCVA, intraocular pressure and CCT measurements which were found to be lower among KC group compared to the control one. There were highly significant differences between the studied groups regarding TCT measurement detected by Pentacam HR and AS-OCT which was found to be lower among the keratoconus group compared to the control one (470.9, 455.7 versus 541.9 and 518.7 respectively). CONCLUSION: Both Scheimpflug-based imaging and AS-OCT provide comparable readings with a good agreement regarding corneal pachymetry in keratoconus group with accurate identification of KC eyes and healthy ones. However, there was a significant difference in K readings between both devices in Keratoconus and control group.


Assuntos
Córnea , Paquimetria Corneana , Ceratocone , Humanos , Córnea/diagnóstico por imagem , Paquimetria Corneana/métodos , Topografia da Córnea/métodos , Ceratocone/diagnóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/métodos
14.
BMC Ophthalmol ; 23(1): 453, 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37957578

RESUMO

BACKGROUND: To investigate the difference between the predicted preoperative corneal ablation depth and the measured ablation depth for femtosecond laser in situ keratomileusis (FS-LASIK) in patients with different degrees of myopia, and to analyze the source of the difference. METHODS: A total of 55 patients (109 eyes) were included in this study. Multiple logistics regression was applied to analyze the sources affecting postoperative refractive outcomes. The difference between the preoperative predicted corneal ablation depth and the 1-day postoperative ablation depth in patients with different degrees of myopia was explored using linear regression. Corneal biomechanical parameters influencing error in ablation depth calculation were examined using multiple linear regression. RESULTS: One hundred and nine eyes were divided into low to moderate myopia (55 eyes, myopia of 6 D or less), high myopia (45 eyes, myopia ranging from 6 D to a maximum of 9 D), and very high myopia group (9 eyes, myopia greater than 9 D) based on preoperative refractive error (spherical equivalent). Postoperative visual outcomes were comparable among the three groups of patients, with no significant difference in uncorrected visual acuity (UCVA). We did find notable disparities in spherical equivalent (SE) and central corneal thickness (CCT) in patients with different degrees of myopia at 1 day postoperatively (all p < 0.001). Logistic regression analysis showed that error in ablation depth calculation was an independent risk factor for refractive outcomes one day after surgery (OR = 1.689, 95% CI: 1.366 - 2.089). There was a substantial discrepancy in error in ablation depth calculation at 1 day postoperatively between the three groups. The measured ablation depth of the laser platform was lower than the predicted ablation depth in the low to moderate myopia and very high myopia groups, but the opposite was true in the high myopia group. Pre-operative SE (p < 0.001) and corneal front minimum radius of curvature (Front Rmin) (p = 0.007) obviously influenced the error in ablation depth calculation. CONCLUSIONS: Error in ablation depth calculation values vary significantly between patients with different degrees of myopia and correlate highly with preoperative SE and Front Rmin. At the same time, the available evidence suggests that error in ablation depth calculation is an influential factor in postoperative refractive status, so it is imperative to control error in ablation depth calculation.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Estudos Prospectivos , Lasers de Excimer/uso terapêutico , Córnea/cirurgia , Refração Ocular , Miopia/cirurgia
15.
BMC Ophthalmol ; 23(1): 10, 2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36604657

RESUMO

PURPOSE: To compare the intra-device repeatability and inter-device reproducibility between two anterior segment imaging instruments, the CASIA SS-1000 (Tomey Corp., Nagoya, Japan) and Pentacam (OCULUS, Arlington, WA) in measuring anterior segment parameters. METHODS: Single-center, prospective clinical trial. Participants ≥20 years of age were included. One eye was randomly selected, each imaged by three CASIA SS-1000 devices and three Pentacam devices by three different examiners. Each photographer operated a pair of devices, one CASIA SS-1000 and one Pentacam. The image order for each participant was determined by a random permutation table. Three images were taken from each device. A total of 18 images were taken for each eye. Ratios of the standard deviations, referenced as (CASIA/Pentacam), were calculated to compare the repeatability and reproducibility of the two imaging instruments. RESULTS: In all, 66 participants with a mean age of 46.4 years (±21.7) were enrolled in the study. All repeatability ratios and intra-device variability were less than 1 (anterior corneal curvature: flat = 0.86, steep = 0.85; posterior corneal curvature: flat = 0.43, steep = 0.61; and map: thinnest = 0.22; central = 0.24, 2 mm = 0.26, 4 mm = 0.27, and 6 mm = 0.30). All reproducibility ratios, which measure the inter-device variability, were less than 1 (anterior corneal curvature: flat = 0.58, steep = 0.73; posterior corneal curvature: flat = 0.25, steep = 0.31; and pachymetry map: thinnest = 0.20; central = 0.20; 2 mm = 0.20; 4 mm = 0.19; and 6 mm = 0.22). A ratio of less than 1 indicates that the CASIA SS-1000 has more consistent measurements. CONCLUSIONS: The CASIA SS-1000 was found to have better repeatability and reproducibility compared to the Pentacam for both corneal curvature and pachymetry maps. This greater consistency may require further study to determine whether the decreased variability can be translated into improved clinical results.


Assuntos
Segmento Anterior do Olho , Córnea , Humanos , Pessoa de Meia-Idade , Córnea/diagnóstico por imagem , Córnea/cirurgia , Paquimetria Corneana , Topografia da Córnea/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica
16.
BMC Ophthalmol ; 23(1): 5, 2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36597084

RESUMO

BACKGROUND: To evaluate corneal topography and densitometry features in patients with polycystic ovary syndrome (PCOS) and compare them with healthy individuals. METHODS: 53 eyes of 53 female patients diagnosed with PCOS and 53 eyes of 53 age-matched female volunteers were analyzed in the study. In addition to the detailed ophthalmological and gynecological examination, anterior segment analysis was performed using Pentacam. A complete analysis of aberrometric, keratometric, topometric, and, densitometric values between the groups was performed, and the results were outlined. RESULTS: According to the results, although Kmax-front, Kmean-front, ISV, IVA, IHA, BAD_D and PI-Avg values were slightly higher in PCOS group along with a slight thinning in the thinnest location, there was no statistically significant difference between the groups. Moreover, correlation analysis between PCOS clinical parameters and keratometric/topometric/aberrometric data were found to be almost normal. Yet, when Pentacam tomography maps of all cases are examined in detail, mild ectatic changes were observed in 5 cases in PCOS group. Furthermore, a significant increase in thickness across all densitometry values except anterior (10-12 mm), central (10-12 mm), and total (10-12 mm) was found in PCOS group. CONCLUSIONS: Our study showed that an intensification of corneal densitometry values ​​and various changes in keratometry data implying ectasia can be observed in patients with PCOS. Prospective studies with larger patient series are needed to reveal any potential relationship between PCOS and corneal abnormalities.


Assuntos
Ceratocone , Síndrome do Ovário Policístico , Humanos , Feminino , Topografia da Córnea/métodos , Síndrome do Ovário Policístico/diagnóstico , Estudos Prospectivos , Córnea , Paquimetria Corneana/métodos , Densitometria , Dilatação Patológica , Ceratocone/diagnóstico
17.
Ophthalmic Physiol Opt ; 43(1): 160-169, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36183360

RESUMO

PURPOSE: To determine the 3-year changes in anterior and posterior values of corneal asphericity (Q) in 6- to 12-year-old children. METHODS: The first and second phases of the study were conducted in 2015 and 2018, respectively. The target population in the first phase was 6- to 12-year-old students in Shahroud, Iran. Multistage cluster sampling was performed on urban students. Additionally, all rural students in Shahroud county were invited to participate. Corneal imaging and ocular biometry were performed using the Pentacam-HR and Allegro Biograph, respectively. RESULTS: A total of 4961 right eyes were analysed in this report. The mean (95% confidence interval) anterior and posterior Q values for an 8-mm chord diameter were -0.38 ± 0.11 (-0.39 to -0.38) and -0.32 ± 0.12 (-0.33 to -0.32) in the first phase of the study, respectively. The mean 3-year changes in anterior and posterior Q values were 0.00 ± 0.08 (95% CI: 0.00-0.00) and -0.01 ± 0.06 (95% CI: -0.01 to -0.01), respectively. Based on a multiple regression model, advancing age (ß = -0.002; [-0.003 to -0.001]), 3-year increase in mean keratometry (ß = -0.04; [-0.06 to -0.02]), central corneal thickness (ß = -0.001; [-0.001 to -0.000]), lens thickness (-0.05; [-0.11 to -0.003]) and anterior chamber depth (-0.09; [-0.15 to -0.03]) showed a statistically significant association with increased anterior Q prolation. Increased axial length was associated with a decrease in Q (ß = 0.02; [0.004 to 0.03]). In addition, female gender (ß = -0.004; [-0.007 to -0.001]) was significantly associated with a more prolate posterior Q value, while rural residence (ß = 0.005; [0.002 to 0.009]) was significantly associated with a more oblate posterior Q value. CONCLUSION: Three-year changes in anterior and posterior Q values were very small. The cornea tends to become more prolate with increasing age.


Assuntos
Criança , Humanos , Feminino , Irã (Geográfico)/epidemiologia
18.
Aesthetic Plast Surg ; 47(6): 2432-2439, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37097452

RESUMO

PURPOSE: To analyze the corneal morphological parameters before and one month after the upper eyelid (UE) blepharoplasty and external levator resection (ELR) for ptosis surgery. MATERIALS AND METHODS: Seventy eyes of 70 patients with dermatochalasis (50 eyes) and acquired aponeurotic ptosis (AAP) (20 eyes) included in this prospective study. Detailed ophthalmologic examination was performed including the best corrected visual acuity (BCVA), slit lamp examination and dilated fundoscopy. Measurements were made before and one month after the surgeries using Pentacam. Central corneal thickness (CCT), pupil center pachymetry (PCP) and thinnest pachymetry (TP), cornea front astigmatism (AST), flat keratometry (K1), steep keratometry (K2) and mean keratometry (Km) values were evaluated. RESULTS: Higher postoperative Km measurements were observed in dermatochalasis (p = 0.038) patients. Postoperative AST values were significantly lower in both dermatochalasis and ptosis cases (p = 0.034, p = 0.003, respectively). Increased PCP and TP were found in the AAP patients (p = 0.014, p = 0.015, respectively). DISCUSSION: UE blepharoplasty and ELR surgeries both lead to some significant changes on corneal structure post-operatively. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Astigmatismo , Blefaroplastia , Blefaroptose , Humanos , Estudos Prospectivos , Pálpebras/cirurgia , Blefaroptose/diagnóstico , Blefaroptose/cirurgia , Córnea/cirurgia , Astigmatismo/cirurgia
19.
Cutan Ocul Toxicol ; 42(4): 198-203, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37417933

RESUMO

PURPOSE: To assess the effect of chronic cigarette smoking on corneal and lens densitometry measurements using Pentacam HR and to compare the results obtained with those in non-smokers. MATERIALS AND METHODS: This cross-sectional comparative study included 40 chronic-smokers and 40 age-matched healthy non-smokers between 18-40 years. After general ophthalmic examination, the Pentacam HR imaging system was used to evaluate corneal and lens densitometry measurements of smokers and non-smokers. RESULTS: The mean corneal densitometry values were not statistically significantly different in all the concentric zones and layers in the eyes of the smokers and non-smokers (p > 0.05, for all). However, the mean values of zone 1, zone 2, zone 3 and average lens densitometry measurements of the smokers were statistically significantly higher compared to non-smokers (p < 0.05, for all). Additionally, significant positive correlations were detected between the number of pack-years smoked and lens densitometry measurements. CONCLUSION: Lens densitometry measurements of smokers were significantly increased while corneal densitometry measurements were not significantly altered compared to non-smokers. Smoking may contribute to cataractogenesis and smoking and age-related changes may act synergistically to cataract development among smokers.


Assuntos
Cristalino , Fumar , Estudos Transversais , Fumar/efeitos adversos , Densitometria , Córnea
20.
Cutan Ocul Toxicol ; 42(4): 248-252, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37531133

RESUMO

PURPOSE: We aimed to compare the predictive effect of pre-injection intraocular pressure (IOP) and anterior segment parameters on post-injection IOP values after intravitreal bevacizumab injection for neovascular age-related macular degeneration (NVAMD) in phakic and pseudophakic patient groups. MATERIAL AND METHODS: This retrospective cross-sectional study included 65 eyes of 65 treatment-naive NVAMD patients. Patients were divided into two groups according to their lens status (35 phakic and 30 pseudophakic patients). Pre-injection IOP, anterior segment parameters measured with PENTACAM, and post-injection IOP values measured at the 5th minute were recorded. Univariate and multivariate regression analyses were used to recognise the predictive effect of pre-injection IOP and anterior segment parameters on post-injection IOP for each group. RESULTS: Multivariate regression analyses showed that the decrease in anterior chamber depth (ACD), and the increase in pre-injection IOP were significantly correlated with higher post-injection IOP in the phakic patient group (p = 0.019 and 0.031; respectively). No correlation was found in the pseudophakic patient group. CONCLUSION: Pre-injection ACD and IOP values may be predictive of higher post-injection IOP in phakic patients. Preoperative assessment of these parameters could be beneficial in patients at risk of glaucoma.


Assuntos
Oftalmopatias , Pressão Intraocular , Humanos , Bevacizumab/efeitos adversos , Inibidores da Angiogênese/efeitos adversos , Estudos Retrospectivos , Estudos Transversais , Injeções Intravítreas , Oftalmopatias/induzido quimicamente