Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 301
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 93, 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38267894

RESUMO

BACKGROUND: This study was designed to explore the clinical efficacy of 3-dimensional (3D) printing assisted minimally invasive percutaneous plate osteosynthesis (MIPO) technique by comparing the clinical outcomes with traditional open reduction and internal plating fixation (ORIF) for treating complex middle-proximal humerus fractures (AO 12C fracture type). MATERIALS AND METHODS: The data of 42 participants who received a complicated middle-proximal humerus fracture from the beginning of 2018 to the end of 2022 were retrospectively analyzed. All patients were assigned to two groups: MIPO with detailed preoperative planning assisted by 3D printing technique (MIPO group), and traditional ORIF (ORIF group). RESULTS: This study included 21 patients in the ORIF group and 21 patients in the MIPO group. All patients were followed-up for at least one year (mean: 16.12 ± 4.13 months), and no difference was observed in the range of shoulder joint motion (ROM), Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) scores and Constant scores between the two groups. However, the occurrence of complications (surgical incision site infection, implant loosening, bone nonunion and radial nerve palsy) in ORIF group was remarkably higher compared to the MIPO group. All the cases achieved bone union within the MIPO group. Significant differences were found in surgical time, intraoperative blood loss and fracture healing time between the two groups. CONCLUSION: Preoperative 3D printing assisted MIPO technique exhibits obvious advantages in high operational efficiency and low occurrence of complications, which is worthy of clinical application for treating complex middle-proximal humeral shaft fractures.


Assuntos
Perda Sanguínea Cirúrgica , Fraturas do Ombro , Humanos , Estudos Retrospectivos , Placas Ósseas , Impressão Tridimensional , Úmero/diagnóstico por imagem , Úmero/cirurgia
2.
Int Orthop ; 48(8): 1997-2005, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38652245

RESUMO

PURPOSE: Periprosthetic femoral fractures (PPFs) around the hip are challenging complications in orthopaedic surgery, particularly Vancouver type B2 (VTB2) fractures. The surgical management of these fractures is crucial and depends on various factors. Cementless short taper stem with plate osteosynthesis is an alternative surgical technique. This study aims to compare the outcomes of this surgical technique with revision arthroplasty (RA) with long stem in the treatment of VTB2 PPFs. METHODS: This retrospective study was conducted in a single medical institute from February 2010 to May 2019. Patients who had received either total hip arthroplasty or bipolar hemiarthroplasty and subsequently developed a VTB2 PPF were included; patients who sustained intra-operative fractures or received a cemented stem previously were excluded from the analysis. The patients were divided into two groups: group I received RA with cementless long stem, while group II underwent RA with cementless short taper stem with plate osteosynthesis. Demographic data, radiographic and functional outcomes, and complications were analyzed between the two groups. RESULTS: A total of 85 patients diagnosed with VTB2 PPFs were included in the study. There were no significant differences between the two groups in terms of demographic data, including age, gender, mean follow-up times, estimated blood loss, and operative times. The radiographic results showed that there was no significant difference in the incidence of subsidence and implant stability between the two groups. However, group II tended to have less subsidence and periprosthetic osteolysis. Patients in group II had significantly better functional scores (mean Harris hip score: post-operative: 60.2 in group I and 66.7 in group ii; last follow-up: 77.4 in group 1 and 83.2 in group II (both p < 0.05)). There were no significant differences in the overall complication rate, including infection, dislocation, re-fracture, and revision surgery, between the two groups. CONCLUSIONS: Both surgical techniques, cementless long stem and cementless short taper stem with plate osteosynthesis, are effective in the treatment of Vancouver B2 PPFs, with no significant differences in outcomes or complications. However, patients in cementless short taper stem with plate osteosynthesis had better functional scores at both post-operative and the last follow-up.


Assuntos
Artroplastia de Quadril , Placas Ósseas , Fraturas do Fêmur , Fixação Interna de Fraturas , Prótese de Quadril , Fraturas Periprotéticas , Reoperação , Humanos , Feminino , Fraturas Periprotéticas/cirurgia , Masculino , Idoso , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/efeitos adversos , Reoperação/métodos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Fraturas do Fêmur/cirurgia , Pessoa de Meia-Idade , Prótese de Quadril/efeitos adversos , Idoso de 80 Anos ou mais , Desenho de Prótese
3.
Arch Orthop Trauma Surg ; 144(4): 1637-1645, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38351348

RESUMO

INTRODUCTION: The frequency of proximal humeral fractures shows an increasing tendency, especially in the elderly, who are frequently affected by osteoporosis. The adequate treatment of complex, displaced fractures poses a serious challenge. Among surgical treatment options, osteosynthesis with an angular stable plate is preferred, however, the implant-related complication rate may be exceptionally high. In our present study, we report the short-term outcomes of our new method of valgising angular stable plate fixation which we use for multifragmentary, displaced proximal humeral fractures in elderly patients. MATERIALS AND METHODS: We retrospectively evaluated the clinical and radiological outcomes of 52 patients (46 female and 6 male, age: 71.9 ± 9.6) who suffered dislocated three- or four-part fractures and underwent valgising angular stable plate fixation. RESULTS: Mean follow-up time was 17.3 months, while the functional outcomes were as following: excellent in 26, good in 18, moderate in 5 and poor in 3 patients. The mean Constant-Murley Score was 82.5 ± 11.2. Functional outcomes only showed significant correlation (p = 0.031) with age and were proven unrelated to fracture type, BMI and known primary diseases. The cumulative complication rate was 9.6% and revision rate was 5.8%. Neurological deficit, pseudoarthrosis or avascular humeral head necrosis did not occur during the follow-up period. CONCLUSIONS: Valgising angular stable plate fixation that we apply for proximal humeral fractures provided favourable functional outcomes and a low postoperative complication rate due to the optimal head and plate placement. The method is especially effective for the treatment of displaced three- and four-part fractures with weakened, osteoporotic bone structure.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Humanos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estudos Retrospectivos , Placas Ósseas , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fraturas do Ombro/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Fraturas do Úmero/complicações
4.
J Orthop Traumatol ; 25(1): 41, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39225851

RESUMO

BACKGROUND: Distal femoral fractures account for less than 1% of all fractures. The therapy of choice is usually surgical stabilization. Despite advances in implant development over the past few years, complication rate remains comparatively high. The aim of this study is to analyze our results with plate fixation of distal femoral fractures with a focus on complication and fracture healing rates. METHODS: In this retrospective cohort study, patients (> 18 years) with distal femoral fractures treated at an urban level I trauma center between 2015 and 2022 were analyzed. RESULTS: In total, 206 patients (167 female, 39 male) with an average age of 75 (SD 16) years were diagnosed with a fracture of the distal femur. One hundred fourteen of these patients were treated surgically by means of plate osteosynthesis. In 13 cases (11.41%), a revision procedure had to be performed. The indication for surgical revision was mechanical failure in eight cases (7.02%) and septic complication in five cases (4.39%). Periprosthetic fractures were more likely to cause complications overall (19.6% versus 4.76%) and further included all documented septic complications. The analysis of modifiable surgical factors in the context of plate osteosynthesis showed higher complication rates for cerclage in the fracture area compared with plate-only stabilizations (44.44% versus 22.22%). CONCLUSIONS: The data show an increased amount of revisions and a significantly higher number of septic complications in the treatment of periprosthetic fractures of the distal femur compared with non-periprosthetic fractures. The detected combination of plates together with cerclage was associated with higher complication rates. Level of evidence Level III retrospective comparative study.


Assuntos
Placas Ósseas , Fraturas do Fêmur , Fixação Interna de Fraturas , Fraturas Periprotéticas , Complicações Pós-Operatórias , Humanos , Feminino , Estudos Retrospectivos , Masculino , Fraturas do Fêmur/cirurgia , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/etiologia , Idoso , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Reoperação , Consolidação da Fratura , Fraturas Femorais Distais
5.
BMC Musculoskelet Disord ; 24(1): 583, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37460932

RESUMO

PURPOSE: Humeral shaft fractures (HSFs) can be treated non-operatively (Non-OP), with open reduction and plate osteosynthesis (ORPO), minimally invasive plate osteosynthesis (MIPO), or with intramedullary nails (IMN). However, the best treatment for HSFs still remains controversial.We performed a network meta-analysis to explore which should be the best method for HSFs. METHODS: The computerized search had been conducted on electronic databases PubMed, EMBASE, Cochrane Library, and Medline from the establishment of the database to the end of December 2022. The quality evaluation of the included literature had been completed by Review Manager (version 5.4.1). Stata 17.0 software (Stata Corporation, College Station, Texas, USA)was used for network meta-analysis.We included randomized controlled trials (RCTs) comparing different treatments to treating HSFs. RESULTS: The pairwise comparison results demonstrated that there was no statistical difference between IMN, MIPO, Non-OP, and ORPO in terms of radial nerve injury and infection, and Non-OP presented significantly more nonunion than ORPO, IMN, and MIPO. However, no statistically significant difference between ORPO, IMN, and MIPO was discovered. The results of the network meta-analysis displayed that surface under the cumulative ranking curve (SUCRA) probabilities of IMN, MIPO, Non-OP, and ORPO in radial nerve injury were 46.5%, 66.9%, 77.3%, and 9.3%, respectively, in contrast, that in infection were 68.6%, 53.3%, 62.4%, and 15.4%, respectively, and that in nonunion were 51.7%, 93.1%, 0.7%, and 54.5%, respectively. CONCLUSION: We came to the conclusion that MIPO is currently the most effective way to treat HSFs. TRIAL REGISTRATION: Name of the registry: Prospero, 2. Unique Identifying number or registration ID: CRD42023411293.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Úmero , Humanos , Metanálise em Rede , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Fixação Interna de Fraturas/métodos , Fixação Intramedular de Fraturas/métodos , Fraturas do Úmero/cirurgia , Placas Ósseas , Úmero , Resultado do Tratamento
6.
BMC Musculoskelet Disord ; 24(1): 83, 2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36721108

RESUMO

BACKGROUND: Patella fractures account for approximately 1% of all skeletal injuries. Treatment options are vast and no definitive conclusion on what option is the most beneficial could be made so far. Plate osteosynthesis appears to gain in importance. We aim to give insight into the more recent trends and developments as well as establish the epidemiology of patella fractures in Germany by analysing treatment and epidemiological data from a national database. METHODS: Anonymised data was retrieved form a national database. In the period of 2006 to 2020, all patients with patella fractures as defined in ICD-10 GM as their main diagnosis, who were treated in a German hospital were included. Patients were divided into subgroups based on gender and age. Age groups were created in 10-year intervals from 20 years old up to 80 years old with one group each encompassing all those above the age of 80 years old and below 20 years old and younger. Linear regression was performed were possible to determine statistical significance of possible trends. RESULTS: A total of 151,435 patellar fractures were reported. 95,221 surgical interventions were performed. Women were about 1.5 times more likely to suffer from patella fracture than men. The relative number of surgical interventions rose from about 50% in 2006 to 75% in 2020. Most surgical interventions are performed in those over the age of 50. The incidence of complex fractures and plate osteosynthesis has significantly increased throughout the analysed period. CONCLUSIONS: We found a clear trend for surgical treatment in Germany with an increase in surgical procedures. We could also show that this ratio is age-related, making it more likely for younger patients in the age groups from 0 to 70 years old to receive surgical treatment for their patella fracture.


Assuntos
Fraturas Ósseas , Traumatismos do Joelho , Fratura da Patela , Masculino , Humanos , Feminino , Criança , Idoso de 80 Anos ou mais , Recém-Nascido , Lactente , Pré-Escolar , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Fraturas Ósseas/epidemiologia , Fraturas Ósseas/cirurgia , Patela/cirurgia , Fixação Interna de Fraturas , Alemanha/epidemiologia
7.
BMC Musculoskelet Disord ; 24(1): 867, 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37936156

RESUMO

BACKGROUND: In minimally invasive lateral plate osteosynthesis of the humerus (MILPOH) the plate is introduced through a deltoid split proximally and advanced through the central portion of the deltoid insertion and between bone and brachial muscle to the distal aspect of the humerus. The fracture is then indirectly reduced and bridged by the plate. Whereas it has been shown that the strong anterior and posterior parts of the distal deltoid insertion remain intact with this maneuver, its impact on deltoid muscle strength and muscular morphology remains unclear. It was the aim of this study to evaluate deltoid muscle function and MR-morphology of the deltoid muscle and its distal insertion after MILPOH. METHODS: Six patients (median age 63 years, range 52-69 years, f/m 5/1) who had undergone MILPOH for diaphyseal humeral fractures extending into the proximal metaphysis and head (AO 12B/C(i)) between 08/2017 and 08/2020 were included. Functional testing was performed for the injured and uninjured extremity including strength measurements for 30/60/90° shoulder abduction and flexion at least one year postoperatively. Constant-Murley-Score (CMS) including an age-and gender-adjusted version, were obtained and compared to the uninjured side. Oxford Shoulder Score (OSS) and the Disability of the Arm, Shoulder and Hand (DASH) questionnaire were acquired for the affected extremity. Quality of life was measured using the EQ visual analogue scale (EQ-5D-5 L VAS). MR imaging was performed for both shoulders accordingly at the time of follow-up to assess the integrity of the distal insertion, muscle mass and fatty degeneration of the deltoid muscle. Muscle mass was determined by measuring the area of the deltoid muscle on the axial MR image at the height of the center of the humeral head. RESULTS: Median follow-up was 29 months (range 12-48 months). Median difference of abduction strength after MILPOH was + 13% for 30°, 0% for 60° and - 22% for 90°. For flexion, the difference to the uninjured side was measured 5% for 30°, -7% for 60° and - 12% for 90°. Median CMS was 75 (66-82) for the operated extremity compared to 82 (77-90) for the uninjured side. Age- and gender-adapted CMS was calculated 88 (79-99) vs. 96 (89-107). Median OSS was 47 (40-48). DASH was 26 (15-36). EQ-5D-5 L VAS ranged from 81 to 95 with a median of 90. The median difference of the deltoid muscle area on MRI was 2% (-21% to + 53%) compared to the uninjured side. No fatty degeneration of the deltoid muscle was observed. The weaker central part of the distal deltoid insertion was exclusively perforated by the plate, leaving the strong anterior and posterior parts of the insertion intact in all patients. CONCLUSIONS: MILPOH was associated with good functional and subjective outcome. Minor impairment of abduction strength was observed with increasing abduction angles. The reason for this impairment is unclear since MILPOH did not affect the structural quality of the deltoid muscle and the integrity of the strong anterior and posterior parts of its insertion remained intact. TRIAL REGISTRATION: 26/05/2023: ISRCTN51786146.


Assuntos
Fraturas do Ombro , Ombro , Humanos , Pessoa de Meia-Idade , Idoso , Músculo Deltoide/diagnóstico por imagem , Músculo Deltoide/cirurgia , Qualidade de Vida , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fixação Interna de Fraturas/métodos , Úmero , Placas Ósseas , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Imageamento por Ressonância Magnética , Resultado do Tratamento
8.
Clin Anat ; 36(3): 377-385, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36104939

RESUMO

A subclavian artery aneurysm after clavicle fracture and plate osteosynthesis in a suspected case of a screw that was too long led us to investigate body donor cadavers. The aim was to verify clavicle variability, and the course of the neurovascular bundle in relation to the clavicle and to the osteosynthesis plate, in order to clarify safe zones for plate and screw fixation. We used one fresh frozen and 25 embalmed donors for in situ measurements: (1) length and craniocaudal thickness of the clavicle, (2) distances between the sternal end of the clavicle and the center of parts of the neurovascular bundle. The clavicle was 15.15 cm long. The mean distances from the sternal end of the clavicle were 5.62 cm to the subclavian vein, 6.75 cm to the subclavian artery and 8.42 cm to the cords of the brachial plexus. The subclavius muscle was 1 cm thick. Because of sex differences in length and distances, we recorded the distances between the sternal end and parts of the neurovascular bundle as ratios of clavicle length (at-risk area) to provide sex-independent parameters: 0.379 for the vein, 0.449 for the artery and 0.554 for the nerve. The neurovascular bundle runs below the clavicle between the medial fourth and three fifths of clavicle length. To avoid iatrogenic neurovascular injuries, special caution is necessary during drilling and screwing the osteosynthesis. We also recommend using screws shorter than 1.4 cm.


Assuntos
Plexo Braquial , Fraturas Ósseas , Humanos , Masculino , Feminino , Clavícula/irrigação sanguínea , Clavícula/lesões , Clavícula/cirurgia , Fixação Interna de Fraturas , Fraturas Ósseas/cirurgia , Ombro , Artéria Subclávia
9.
Int Orthop ; 47(9): 2327-2336, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37477682

RESUMO

PURPOSE: Complex bicondylar tibial plateau fracture (TPF) has always been a tricky problem for surgeons. We created a novel external device used intraoperatively consisting of Kirschner wires, and combined with minimally invasive plate oseoynthesis (MIPO) technique to treat complex bicondylar TPFs, and the clinical effect and feasibility were further evaluated. METHODS: From March 2016 to February 2021, 49 cases (29 males and 20 females) were identified as bicondylar TPF, the mean age 47.2 (27-69). All patients adopted the device and MIPO technique. A series of score, complications, and radiographs in the follow-up period, from three months, six months, one year, and two years and the last follow-up, were recorded, from visual analogue score (VAS), hospital for special surgery (HSS), and Short-Form 36 (SF-36), containing physical (PCS) and mental (MCS), and Rasmussen score. RESULTS: Forty-seven patients showed good functional recovery. No patients were lost, mean follow-up time was 28.17 ± 2.81 (24.2-35.4) months. Operation time was 89.80 ± 13.46 (58-110) min. At the last follow-up, VAS was 1.3 ± 0.92 (0-4), HHS was 93.10 ± 2.63 (89-99), PCS was 49.20 ± 7.40 (38-65), and MCS was 50.08 ± 4.77 (43-62). Complications were as follows: cutaneous necrosis (3, 6%), asymptomatic arthritis (3, 6%), symptomatic arthritis (1, 2%), and deep venous thrombosis (1, 2%). Mean fracture healing time was 11.82 ± 1.5 (10-15.4) weeks. All patients got recovery without extra surgery and removed the implants at 12.85 ± 0.76 (11.2-15.4) months. CONCLUSION: Temporary traction device of bilateral external fixator combined with MIPO technique was simple and convenient, with a smaller soft-tissue damage, an easier operational approach, and its worth being promoted.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Fixadores Externos , Fixação Interna de Fraturas/métodos , Fixação de Fratura/métodos , Fraturas da Tíbia/cirurgia , Fios Ortopédicos , Tração , Placas Ósseas , Resultado do Tratamento
10.
Arch Orthop Trauma Surg ; 143(11): 6657-6664, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37530845

RESUMO

INTRODUCTION: Minimally Invasive Percutaneous Plate Osteosynthesis (MIPPO) is increasingly favored for treating humeral shaft fractures (HSFs). However, conventional MIPPO techniques pose challenges in fixing fractures near fossa olecranon and carry a risk of iatrogenic radial nerve palsy. A novel technique using a medial MIPPO for treating humeral shaft fractures (HSFs) is described. Results of clinical follow-up are presented. MATERIALS AND METHODS: This study is a retrospective case series study. Twenty-one patients (mean age 43.9 ± 17.66 [22‒81] years) with HSFs were treated with the novel MIPPO fixation method. Clinical outcomes including time for radiographic consolidation, Disabilities of the Arm, Shoulder, and Hand (DASH) score, and complications were assessed at the last follow-up. The mean follow-up was 26 ± 17.12 (range 12-67) months. RESULTS: All patients had a bony union at a mean of 15.76 ± 6.74 (range 8-40) weeks based on X-ray with an early and aggressive range of motion. The complication rate was 0. The mean DASH score was3.29 ± 4.09 (range 0-14.17) at the time of the last follow-up. The mean screw density was 0.49 ± 0.1 (range 0.2-0.65). CONCLUSION: This novel surgical technique for HSFs is a viable alternative to previously described methods with the advantage of being less prone to nerve injury and easy to fix distal extra-articular HSFs. The learning curve is short. LEVEL OF EVIDENCE: IV.


Assuntos
Fraturas Distais do Úmero , Fraturas do Úmero , Humanos , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fraturas do Úmero/cirurgia , Fraturas do Úmero/complicações , Fixação Interna de Fraturas/métodos , Placas Ósseas , Úmero
11.
Arch Orthop Trauma Surg ; 143(11): 6955-6963, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37526738

RESUMO

INTRODUCTION: Scaphoid is the most fractured carpal bone, with a 5-10% nonunion rate. Treatment challenges include choosing the implant and graft that best corrects humpback deformity and carpal malalignment with higher chances of bony healing. OBJECTIVE: Compare cortico-cancellous and cancellous grafts between two groups of patients treating scaphoid nonunion with locking plates using autologous bone graft and evaluate bone healing rates and radiographic, tomographic, and functional parameters before and after surgery. METHODS: Non-randomized prospective study including 20 cases of scaphoid nonunion. Groups were divided into Group A (ten patients treated with cortico-cancellous iliac graft) and Group B (ten patients treated with cancellous iliac graft). Patients underwent pre- and postoperative radiographs, computed tomography, and functional evaluation. RESULTS: In postoperative analysis, Group A showed a statistically significant difference in intrascaphoid angle (p = 0.002) and scapholunate angle (p = 0.011) correction when comparing the pre- and postoperative periods. Group B showed a statistically significant difference in intrascaphoid angle (p = 0.002) and scapholunate angle correction (p = 0.0018), grip strength (p = 0.002), and tip pinch strength (p = 0.001) when comparing the pre- and postoperative periods. By comparing both groups, Group B showed a statistically significant difference in intrascaphoid angle correction (p = 0.002), grip strength (p = 0.002), tip pinch strength (p = 0.002), and radial deviation (p = 0.0003). There was no statistical difference when comparing bony healing between groups. CONCLUSION: Scaphoid nonunion treatment with a locking plate was effective, showing a high bony healing rate and improved carpal alignment in imaging tests for both graft types. However, results for intrascaphoid angle correction, grip strength, tip pinch strength, and radial deviation were better in Group B. LEVEL OF EVIDENCE: IV, case series.


Assuntos
Fraturas não Consolidadas , Pseudoartrose , Osso Escafoide , Humanos , Pseudoartrose/etiologia , Fraturas não Consolidadas/diagnóstico por imagem , Fraturas não Consolidadas/cirurgia , Fraturas não Consolidadas/etiologia , Estudos Prospectivos , Estudos Retrospectivos , Osso Escafoide/cirurgia , Fixação Interna de Fraturas/métodos , Transplante Ósseo/métodos
12.
Arch Orthop Trauma Surg ; 143(1): 365-371, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35041081

RESUMO

In this investigation, it was assumed that it must be possible to visualize the intrapelvic aspect as accustomed by pelvic surgeons using the anterior intrapelvic (modified Stoppa) approach. Moreover, it was hypothesized, that plate mountings will not only be possible for the symphysis but also at the supra- and infrapectineal aspect as well as to the posterior column. Ten anonymized cadaveric specimens were included in this study. A standard laparoscopic totally extraperitoneal (TEP) approach was used. A total of 10 landmarks were defined that are usually within reach in the open anterior intrapelvic (AIP) approach. Moreover, five different plate mountings were tested. The locations were chosen in accordance with the indication spectrum suitable for open surgery through the traditional AIP approach. It was possible to gain intrapelvic visibility in seven of ten cases. In all of those seven cases, it was technically possible to place plates to the symphysis, superior pubic ramus, as well as longer anterior column plates up to the aspect posterior of the acetabulum. In the last four of the seven cases, it was possible to mount plates to the infrapectineal aspect as well as the posterior column, too. The team, previously trained in arthroscopic surgical techniques as well as pelvic trauma surgery, observed a steep learning curve. This investigation demonstrated, that endoscopic anterior intrapelvic plate osteosynthesis was feasible in the majority of the cases in a series of ten cadaveric models. New instruments will be needed such as extra-long rasp elevators, ball-spikes as well as devices to hold and position plates and extra-long self-holding screwdrivers. With these, endoscopic pelvic surgery will likely be a realistic option for selected pelvic trauma cases in the future.


Assuntos
Fraturas Ósseas , Humanos , Fraturas Ósseas/cirurgia , Estudos de Viabilidade , Fixação Interna de Fraturas/métodos , Acetábulo/cirurgia , Placas Ósseas , Cadáver
13.
J Foot Ankle Surg ; 62(3): 422-425, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36404255

RESUMO

There are no clinical studies about treatment of distal tibia fractures using far cortical locking (FCL) screws, even though it has been shown to be superior to standard locking screws in biomechanical studies. We compared the efficacy of FCL screws to that of traditional locking screws. Twenty-five distal tibia fractures were treated with minimally invasive plate osteosynthesis using traditional locking screws, whereas 20 were treated using FCL screws. We retrospectively compared time taken for callus formation and radiographic bone union between 2 groups. The effect of age, sex, diabetes, and smoking history on bone healing was analyzed. Complications were also noted. As a result, there was no significant difference in age (p = .292), sex (p = 1.0), diabetes (p = 1.0), or smoking history (p = .704) between 2 groups. Time to callus formation was 77.5 days in the FCL group, and 96 days in the traditional group (p = .023). Average time to bone union was 134.8 days, and 163.1 days in the FCL group and the traditional group, respectively (p = .017). There was one case of screw loosening in the FCL group, and one case of screw breakage in the traditional group. This study suggests that FCL screws promote quicker healing of distal tibia fractures than traditional locking screws.


Assuntos
Fraturas do Tornozelo , Fraturas do Fêmur , Fraturas da Tíbia , Humanos , Tíbia , Estudos Retrospectivos , Fraturas do Fêmur/cirurgia , Consolidação da Fratura , Fixação Interna de Fraturas , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Placas Ósseas
14.
J Pak Med Assoc ; 73(5): 1083-1086, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37218238

RESUMO

A study was conducted to assess the outcome of close distal tibial fractures fixed with pre-contoured locking-plate using Minimally Invasive Percutaneous Plate Osteosynthesis (MIPPO) technique in terms of union and infection, at the Department of Orthopaedic Surgery King Edward Medical University/Mayo Hospital, Lahore from August 2013 to May 2017. Fourty cases with close distal tibial fractures were enrolled. Fractures were managed with locking compression plate using MIPPO technique. Patients were followed for 12 months post-fracture stabilisation. Of the 40 patients 24 were males and 16 females, with male to female ratio of 1.5:1. The mean age of the patients was 44.70±13.67 years with minimum and maximum ages of 18 and 60 years, respectively. All fractures united with the mean union time of 16±4 weeks. The infection rate was 5%. Locking compression plate when used with MIPPO technique provides early bone union and low infection rate.


Assuntos
Tíbia , Fraturas da Tíbia , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fixação Interna de Fraturas/métodos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Placas Ósseas , Resultado do Tratamento , Consolidação da Fratura
15.
Foot Ankle Surg ; 29(8): 566-575, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37532663

RESUMO

BACKGROUND: This systematic review evaluates postoperative complications and functional outcomes of minimally invasive plate osteosynthesis (MIPO) for distal tibial pilon fractures. This paper aims to fill a key literature gap, as no previous reviews have specifically addressed MIPO for tibial pilon fractures or fractures other than those involving the humeral shaft. METHODS: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A systematic literature search was done using PubMed, Embase, Web of Science, and Scopus databases from 2000 to 2022. Inclusion criteria were MIPO treatment in skeletally mature patients, while exclusion criteria were non-English papers, conference abstracts, papers with multiple treatment modalities that didn't analyze MIPO outcomes separately, skeletally immature patients, case reports, and cohorts smaller than five patients. Unpublished papers were also searched using Clinical Trials. Data extraction included general study information, injury specification, outcome measures, and complications. Finally, a risk of bias assessment (RoB) was performed. RESULTS: A total of 1732 studies were identified, of which 23 were included in this review, with 673 patients and 678 fractures analyzed. The mean follow-up ranged from 6 to 62.53 months, with most studies representing intermediate to long-term follow-up. Primary outcome measures showed that 87.33% achieved 'excellent to good' results, 8.67% achieved 'fair' results, and 4% achieved 'poor' results. Stratified by fracture type, 76.47%, 80.05%, and 76.92% of AO/OTA type A, B, and C fractures, respectively, achieved 'excellent to good' results. 35.06% of cases reported complications (236 in total). These included one case of deep infection (0.148%), 28 superficial wound infections (4.16%), 4 nonunion cases (0.59%), and 22 malunion instances (3.27%). RoB assessment showed that 52.17% had a moderate overall risk of bias, 39.13% had a serious overall risk of bias, and 8.7% had a critical overall risk of bias. CONCLUSION: MIPO technique for pilon fractures showed good functional outcomes and reliability, with low complication rates and should be considered in cases where proper indirect reduction is possible. However, while the evidence is promising, further high-quality studies with larger sample sizes, longer-term follow-up, and comparison to other techniques are needed to evaluate the efficacy and safety of this technique. LEVEL OF EVIDENCE: IV.


Assuntos
Fraturas do Tornozelo , Fraturas da Tíbia , Humanos , Reprodutibilidade dos Testes , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fraturas da Tíbia/cirurgia , Fixação Interna de Fraturas/métodos , Tíbia/cirurgia , Placas Ósseas , Resultado do Tratamento , Consolidação da Fratura
16.
Eur J Orthop Surg Traumatol ; 33(7): 3067-3079, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37020158

RESUMO

PURPOSE: The treatment of extraarticular proximal tibial fractures is challenging. As the optimal fixation technique is still debated, the purpose of this study was to compare minimally invasive plate osteosynthesis (MIPO) and intramedullary nail (IMN) fixation. METHODS: A prospective matched comparative study was conducted on patients with displaced extraarticular proximal tibia fractures treated with MIPO (n = 29) versus IMN (n = 30) fixation. Outcomes collected were the Johner-Wruhs grading, range of motion (ROM), union rate, time to union, malunion, coronal and sagittal alignment, and post-operative complications. RESULTS: Union rates were similar between the MIPO and IMN groups (93% vs. 97%, P = 1.0). The IMN group had an earlier time to union (15 vs. 18 weeks, P < 0.001) and superior functional outcomes at one year (effective Johner-Wruhs score: 80% vs. 55%, P = 0.04). There was a significantly higher incidence of anterior knee pain in the IMN group (23% vs. 0%, P = 0.02) and there was a trend for more infections in the MIPO group (21% vs. 13%, P = 0.73). CONCLUSION: IMN fixation of extraarticular proximal tibia fractures was associated with a shorter union time and better functional scores compared to MIPO.


Assuntos
Fixação Intramedular de Fraturas , Fraturas da Tíbia , Humanos , Tíbia/cirurgia , Fixação Intramedular de Fraturas/efeitos adversos , Fixação Intramedular de Fraturas/métodos , Estudos de Coortes , Estudos Prospectivos , Fraturas da Tíbia/cirurgia , Resultado do Tratamento , Consolidação da Fratura , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Placas Ósseas
17.
J Orthop Traumatol ; 24(1): 54, 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37816859

RESUMO

BACKGROUND: Plate osteosynthesis with implants made of carbon-fibre-reinforced polyetheretherketone (CFR-PEEK) has recently been introduced for the treatment of fractures of the proximal humerus (PHFs). The advantages of the CFR-PEEK plate are considered to be its radiolucency, its favourable modulus of elasticity, and the polyaxial placement of the screws with high variability of the angle. The primary aim of this study is to investigate the influence of calcar screw positioning on the complication and revision rates after CFR-PEEK plating of PHFs. The secondary aim is to assess its influence on functional outcome. MATERIAL AND METHODS: Patients were identified retrospectively. Minimum follow-up was 12 months. The cohort was divided into two groups depending on the distance of the calcar screw to the calcar (group I: < 12 mm, group II: ≥ 12 mm). The range of motion (ROM), Subjective Shoulder Value Score (SSV) and Constant-Murley Score (CS) were analysed at follow-up examination. Subjective complaints, complications (e.g. humeral head necrosis, varus dislocation) and the revision rate were evaluated. RESULTS: 51 patients (33 female, 18 male) with an average age of 68.6 years were included after a period of 26.6 months (group I: 32 patients, group II: 19 patients). Apart from the gender distribution, no significant differences were seen in the patient characteristics. The outcome scores showed significantly better clinical results in group I: SSV 83.4 vs 71.2, p = 0.007; CS 79.1 vs 67.8, p = 0.013. Complications were seen less frequently in group I (18.8 % vs 47.4 %, p = 0.030). CONCLUSION: This study shows that the positioning of the calcar screw is relevant for CFR-PEEK plate osteosynthesis in PHFs with a good reduction of the fracture. Optimal positioning of the calcar screw close to the calcar (< 12 mm) is associated with a lower rate of complications, resulting in significantly superior functional outcomes. LEVEL OF EVIDENCE: III, retrospective cohort study.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Humanos , Masculino , Feminino , Idoso , Fibra de Carbono , Estudos Retrospectivos , Polietilenoglicóis , Cetonas , Fixação Interna de Fraturas/métodos , Parafusos Ósseos/efeitos adversos , Úmero/cirurgia , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico , Placas Ósseas/efeitos adversos , Resultado do Tratamento
18.
J Shoulder Elbow Surg ; 31(8): 1666-1673, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35247574

RESUMO

BACKGROUND: The purpose of this study was to investigate the primary stability and displacement tendencies of an external fixation system in 2 different configurations in comparison to locking plate fixation in a 3-part proximal humeral fracture model. METHODS: Twenty-one fresh-frozen human cadaveric proximal humeral specimens were divided into 3 groups of 7 stripped specimens. An unstable 3-part fracture of the proximal humerus was set. Construct A consisted of the Galaxy Fixation Shoulder System, with fixation in accordance with the manufacturer's recommended technique (3 pairs of threaded wires). Construct B was fixed with an additional pair of threaded wires according to the recommendations of Gumina et al (4 pairs of threaded wires). The remaining 7 specimens were fixed with a locking plate. By use of an optical motion capture system, relative motion at the fracture site and failure load were evaluated during a cyclic loading protocol. RESULTS: Plate osteosynthesis showed the highest cyclic load to failure (895 ± 239 N; range, 597-1135 N), followed by construct B (692 ± 121 N; range, 432-788 N) and construct A (350 ± 190 N; range, 139-615 N). Statistically significant differences were found between plating and construct A (P < .001), between plating and construct B (P = .031), and between construct B and construct A (P = .013). Relative motion at the fracture site, in terms of change in distance during cyclic loading, was lowest with construct B measured at the peak load of 395 N after 11 steps (1.73 ± 1.98 mm; range, 0.53-5.96 mm) and highest with construct A (8.46 ± 10.67 mm; range, 2.26-20.79 mm). Angular change measured at the peak load after 11 steps was lowest with construct B (1.19° ± 0.36°; range, 0.59°-1.7°) and highest with construct A (2.44° ± 1.63°; range, 0.77°-4.04°). Statistically significant differences were found between construct A and construct B and between construct A and plating at various steps of cyclic loading. CONCLUSION: In this biomechanical study of unstable 3-part proximal humeral fractures, locking plate osteosynthesis demonstrated the highest possible load application. External fixator application with 8 threaded wires (construct B) revealed the least relative motion at the fracture site, without a statistically significant difference compared with locking plates. It therefore represents another valid technique for treatment regarding primary stability. The use of external fixator application with 6 threaded wires (construct A) resulted in the lowest stability and the highest rates of displacement.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Fixadores Externos , Fixação de Fratura/métodos , Fixação Interna de Fraturas/métodos , Humanos , Úmero/cirurgia , Ombro , Fraturas do Ombro/cirurgia
19.
Arch Orthop Trauma Surg ; 142(8): 1895-1902, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33966101

RESUMO

INTRODUCTION: Only a few previous studies have evaluated the factors related to supraclavicular nerve (SCN) injury after clavicle mid-shaft fracture surgery. We analyzed the frequency and risk factors for SCN injury after clavicle mid-shaft fracture surgery via open reduction and internal fixation (ORIF) versus minimally invasive plate osteosynthesis (MIPO) MATERIALS AND METHODS: We retrospectively reviewed the cases from 59 patients who had undergone surgery for clavicle mid-shaft fractures between January 2018 and April 2019. Twenty-nine patients had undergone ORIF and 30 had undergone MIPO. The frequency of SCN injury in the two groups was evaluated, and preoperative patient demographics (age, sex, body mass index, smoking, alcohol, diabetes mellitus, and trauma mechanism), and radiological parameters (fracture displacement and shortening) were measured and evaluated as risk factors for SCN injury. When neurological symptoms, such as numbness, were present on the anterior chest wall or at the incision site, electromyography (EMG) was conducted. RESULTS: Neurological symptoms were present in 12 patients. Numbness in the anterior upper chest around the incision site was present in eight and four patients who underwent ORIF and MIPO, respectively (p < 0.001). Furthermore, fracture displacement evaluated on preoperative three-dimensional computed tomography was significantly associated with the occurrence of SCN injury in patients who underwent MIPO (odds ratio, 1.038; 95% confidence interval, 1.001-1.077; p = 0.047). Although EMG was conducted in all patients with SCN injury, peripheral neuropathy was not found in any cases. CONCLUSIONS: SCN injury, which is a possible complication of clavicle mid-shaft fracture surgery, occurred significantly less frequently in MIPO than in ORIF. In MIPO, greater preoperative fracture displacement was associated with a higher risk of SCN injury. Additional studies are required to reach a consensus regarding accurate methods to evaluate SCN injuries. LEVEL OF EVIDENCE: IV, case series, treatment study.


Assuntos
Fraturas Ósseas , Traumatismos dos Nervos Periféricos , Traumatismos Torácicos , Placas Ósseas , Clavícula/lesões , Clavícula/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Fraturas Ósseas/etiologia , Fraturas Ósseas/cirurgia , Humanos , Hipestesia/etiologia , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Traumatismos dos Nervos Periféricos/epidemiologia , Traumatismos dos Nervos Periféricos/etiologia , Estudos Retrospectivos , Resultado do Tratamento
20.
Arch Orthop Trauma Surg ; 142(6): 1083-1090, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33944989

RESUMO

INTRODUCTION: There is no uniform approach to the management of lateral clavicle fractures. Recent studies have investigated additive coracoclavicular (CC) augmentation as a treatment option; however, it is unclear whether it is superior to conventional locking plate osteosynthesis. METHODS: We carried out a retrospective analysis of 40 patients with lateral clavicle fracture (Neer type IIb) who were treated between 2014 and 2017 with either a hybrid locking plate osteosynthesis/additive arthroscopy-assisted CC augmentation (HP) procedure or a locking plate osteosynthesis only (PO) approach to determine which strategy was more effective. At follow-up, subjective shoulder value, age- and sex-adjusted Constant-Murley score, Taft (TF) score, American Shoulder and Elbow score, Nottingham clavicle score, and Visual Analogue Scale score were compared between patient groups. A radiologic evaluation was also conducted. RESULTS: A total of 14/17 patients (83%; 9 male/5 female, mean age: 43 ± 15 years) were followed up in the PO group. The mean follow-up time was 29 ± 12.4 months. In the HP group, 17/23 patients (74%; 9 male/8 female, mean age: 43 ± 17 years) were followed up, with a mean follow-up time of 18 ± 7.1 months. There were no significant differences in clinical parameters between the HP and PO groups; notably, the shoulder girdle-specific TF score was comparable in the 2 groups (HP: 11.3 ± 1.1 points and PO: 10.9 ± 0.9 points). In the HP group, additional pathologies were identified and arthroscopically treated in 35% of cases. Radiologic examination revealed a significant difference between pre- and postoperative CC distance in the HP group (P = 0.001). CONCLUSION: Additive CC augmentation in combination with locking plate osteosynthesis seems to improve the vertical stability and reduces the revision rate in patients with a lateral clavicle fracture. Furthermore, an arthroscopy-assisted procedure allows for an intraoperative detection and single-step treatment of accompanying intraarticular pathologies.


Assuntos
Clavícula , Fraturas Ósseas , Adulto , Placas Ósseas , Clavícula/cirurgia , Feminino , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Humanos , Ligamentos Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa