Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.057
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Clin Oral Implants Res ; 35(8): 782-792, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38140771

RESUMO

AIM: This scoping review aimed to compile and evaluate clinical trials investigating digital applications in prosthetic diagnostics and treatment planning by assessing their clinical relevance and future potential. METHODS: Following the PCC-framework for scoping reviews and combining the source of analysis (Population/P: "prosthodontics"), the technique of interest (Concept/C: "digital application") and the field of interest (Context/C: "diagnostics"), a three-pronged search strategy was applied in the database PubMed and Web of Science. Clinical trials (≥10 study participants, English/German) were considered until 2023-03-09. Reporting adhered to the PRISMA-ScR statement. RESULTS: The search identified 520 titles, of which 18 full-texts met the inclusion criteria for data extraction. The trials involved a total of 14,457 study participants and were mapped for prosthetic subdisciplines: fixed (n = 9; 50%) and removable (n = 4; 22%) prosthodontics, reconstructive dentistry in general (n = 3; 17%), and temporo-mandibular joint disorders (n = 2; 11%). Data merging of medical format files, as DICOM+STL, was the dominant digital application (n = 7; 39%); and virtual treatment simulation using digital smile design or digital wax-up represented the most frequent prosthetic diagnostics (n = 6; 33%). CONCLUSION: This scoping review identified a relatively low number of clinical trials. The future potential of digital diagnostics appears to be mostly related to the subdiscipline of fixed prosthodontics, especially regarding virtual treatment simulation for communication with the patient and among dental professionals. Artificial intelligence emerged as a key technology in many of the identified studies. Further research in this area is needed to explore the capabilities of digital technologies in prosthetic diagnostics and treatment planning.


Assuntos
Planejamento de Assistência ao Paciente , Prostodontia , Humanos , Prostodontia/métodos , Desenho Assistido por Computador
2.
Clin Oral Implants Res ; 35(8): 922-938, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38308466

RESUMO

OBJECTIVE: To identify the different uses and modalities of digital technologies to diagnose, plan and monitor peri-implant soft tissue conditions and aesthetics. METHODS: A comprehensive narrative review of pertinent literature was conducted, critically appraising key digital technologies that may assist peri-implant soft tissue augmentation and assessment. An electronic search on four databases including studies published prior to 1st July 2023 was performed and supplemented by a manual search. RESULTS: Predominantly, tools such as cone beam computed tomography (CBCT), intraoral scanning (iOS), intraoral ultrasonography and digital spectrophotometry were commonly to assess and monitor peri-implant soft tissues. The main clinical and research applications included: (i) initial assessment of mucosal thickness, supra-crestal tissue height and keratinized mucosa width, (ii) evaluation of peri-implant soft tissue health and inflammation, (iii) monitoring profilometric changes and midfacial mucosal margin stability over time and (iv) aesthetic evaluation through colour assessment. While evidence for some digital tools may be limited, the integration of digital technologies into peri-implant soft tissue management holds great promise. These technologies offer improved precision, comfort and speed in assessment, benefiting both patients and clinicians. CONCLUSION: As digital technologies progress, their full potential in peri-implant soft tissue augmentation and their value will become more evident with ongoing research. Embracing these innovations and their potential benefits is recommended to ensure that during progress in implant dentistry, patient care is not hindered.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Estética Dentária , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Tecnologia Digital , Implantes Dentários , Gengiva/diagnóstico por imagem
3.
Clin Oral Investig ; 28(5): 284, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38684542

RESUMO

OBJECTIVES: The primary objective of the present retrospective clinical study was to determine the survival time of obturators while analyzing possible influencing factors. MATERIALS AND METHODS: This retrospective clinical cohort study analyzed the influence of various clinical factors on the survival probability of obturators and their follow-up outcomes using Kaplan‒Meier analysis. RESULTS: A total of 76 patients with 115 obturators were included in the study (47 men and 29 women, mean age 58.1 ± 18.1 years). The mean observation time was 3.0 ± 4.5 years (maximum 26.3 years). A total of 40.9% (47) of all obturators observed had to be replaced. The survival rate after 5 years was 79.5% for telescopic-crown-retained tooth-supported obturators, 86.9% for telescopic-crown-retained implant-supported obturators, 58.8% for removable full denture obturators, 22.1% for clasp-retained obturators and 0.0% for splints. The type of attachment, attendance at a regular follow-up and defect cause significantly influenced the survival of the obturators (p < .05). CONCLUSIONS: The findings obtained in this study support the recommendation of using implant-supported obturators. Telescopic-crown attachments, either tooth- or implant-supported, seem to be favorable in terms of survival time. Attendance at a strict follow-up program seems to have a major influence on the longevity of the obturators. CLINICAL RELEVANCE: The use of implant-supported obturators to cover permanent oral and maxillofacial defects is highly recommended. Additionally, the use of telescopic-crown attachments seems to be favorable in terms of survival time. Clasp-retained obturators and surgical splints should be used primarily for temporary restorations due to their shorter survival times.


Assuntos
Falha de Restauração Dentária , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Masculino , Feminino , Prótese Dentária Fixada por Implante , Idoso
4.
Acta Odontol Scand ; 82(1): 18-24, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37623701

RESUMO

AIMS: To evaluate limitations in jaw function, oral health-related quality of life (OHRQoL), and nutritional status during extensive oral rehabilitation procedures. MATERIAL METHODS: Fourteen participants (mean age ± SD: 70 ± 3.8) undergoing major oral rehabilitation involving the restoration of a minimum of eight teeth were recruited in the study. Jaw function limitations scores (JFLS), oral health-impact profile (OHIP), and nutritional status were measured at different time points during, six months, and one year after the rehabilitation procedures. Nutritional status was evaluated by measuring the body weight and arm and calf muscle circumference. The effect of time points on the measured variables was evaluated with Friedman's test. Trends in nutritional status were evaluated with linear regression analysis. RESULTS: The results of the analysis showed significant main effects of time points on the JLFS (p < .001) and OHIP scores (p = .005). However, there was no effect of time points on the body weight (p = .917) and calf muscle circumference (p = .424), but a significant effect on arm circumference (p = .038). Further, there was a decreasing trend for body weight (64.3%), arm (71.4%), and calf circumference (64.3%) in the majority of the patients. CONCLUSION: The results of the preliminary study suggest that people undergoing extensive oral rehabilitation procedures show improvement in jaw function and an increase in OHRQoL after the rehabilitation procedure. Despite no major changes in the nutritional indicators, most patients showed a negative trend in their body weight, arm circumference, and calf circumference, suggesting that they may be susceptible to nutritional changes.


Assuntos
Estado Nutricional , Qualidade de Vida , Humanos , Projetos Piloto , Saúde Bucal , Inquéritos e Questionários , Peso Corporal
5.
J Esthet Restor Dent ; 36(2): 278-283, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37681471

RESUMO

OBJECTIVE: The present manuscript describes a technique to virtually switch an implant scan body eliminating the need of obtaining a new intraoral implant digital scan. CLINICAL CONSIDERATIONS: Implant scan bodies assist on transferring the 3-dimensional position of the implants into the virtual definitive implant cast. However, if a different implant part is desired during the designing procedures of the implant restoration such as selecting a different implant abutment of varying height, angulation, or manufacturer, a new intraoral implant digital scan with the specific implant scan body is required. CONCLUSIONS: This novel protocol aims to reduce possible complications that require capturing a new intraoral implant digital scan, facilitate prostheses design modifications after the obtention of the definitive intraoral implant digital scan, and to ease the manufacturing procedures. CLINICAL SIGNIFICANCE: The novel technique may provide a solution for virtually switch implant scan bodies for fabricating implant-supported single crowns or short-span prostheses. Additional studies are needed before its clinical implementation.


Assuntos
Desenho Assistido por Computador , Implantes Dentários , Coroas , Técnica de Moldagem Odontológica , Imageamento Tridimensional
6.
J Esthet Restor Dent ; 36(1): 78-84, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37840220

RESUMO

OBJECTIVE: The purpose of this review was to provide dental professionals with information regarding the various types of zirconia restorations, their mechanical and optical properties, tooth preparation design, and bonding protocol in an effort to enhance the longevity and durability of zirconia restorations. OVERVIEW: The yttria content of zirconia ceramics determines their classification. The mechanical and optical properties of each type are discussed, with an emphasis on the effect of yttria concentration on the properties of zirconia. The processing and sintering methods are also discussed as they have a direct impact on the properties of zirconia. The design of tooth preparation, specifically occlusal reduction, varies depending on the type of zirconia used in each case. Finally, a protocol for zirconia restoration bonding is described to ensure optimal bonding to the tooth structure. CONCLUSION: Not all zirconia restorations are the same. The selection of zirconia type based on yttria concentration, processing and sintering methods, tooth preparation design, and adherence to the bonding protocol are all critical to the success and longevity of zirconia restorations. CLINICAL SIGNIFICANCE: Zirconia restorations are the most commonly used indirect restorative material. The selection of the most appropriate zirconia type based on its yttria content, which determines its strength and translucency, is critical to the success and the longevity of the restoration. Tooth preparation design also influences the strength and translucency of the zirconia. Air-borne particle abrasion, followed by a ceramic primer and resin cement, can ensure a durable bond to the tooth structure.


Assuntos
Colagem Dentária , Ítrio , Colagem Dentária/métodos , Análise do Estresse Dentário , Cerâmica/química , Zircônio/química , Cimentos de Resina/química , Preparo do Dente , Propriedades de Superfície , Teste de Materiais
7.
J Esthet Restor Dent ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38923782

RESUMO

INTRODUCTION: Erbium-doped yttrium-aluminum-garnet (Er:YAG) laser debonding of zirconia and lithium disilicate restorations is increasingly used for a range of clinical applications. Using rotary instruments to remove such restorations for any purpose has proven to be challenging. Erbium laser has been reported to be a conservative method for removing ceramic restorations. There is little data in the literature about the effect of adhesive resin cement type on the debonding time of the ceramic restoration using the Er:YAG laser. OBJECTIVES: To evaluate and compare the time required for the Er:YAG laser to debond zirconia and lithium disilicate crowns bonded with a 2- and 1-bottle adhesive resin cement systems. MATERIALS AND METHODS: Forty extracted premolar teeth were prepared and scanned for milled 40 CAD/CAM crowns. Teeth were randomly assigned into groups (n = 10 per group): 3 mol% yttria-partially stabilized zirconia crowns 3Y-PSZ (G1a) bonded with Panavia™ V5 (2-bottle adhesive resin cement), Zirconia 3Y-PSZ crowns (G1b) bonded with RelyX™ Ultimate (1-bottle adhesive resin cement), and for the lithium disilicate crowns bonded with the two types of cements (G2a, G2b). Each specimen was irradiated with an Er:YAG laser at 335 mJ, 15 Hz, 5.0 W, and 50-ms pulse duration (super short pulse mode). The irradiation time required for crowns to be successfully debonded was recorded for each specimen. Data were statistically analyzed using ANOVA and Tukey HSD post-hoc test (p < 0.05), at the 95 percent level of confidence. The intaglio surface of the debonded crown was analyzed using scanning electron microscopy (SEM). RESULTS: The mean ± standard deviation times needed for crown debonding were 5.75 ± 2.00 min for the G1a group, 4.79 ± 1.20 min for group G1b, 1.69 ± 0.49 min for group G2a, and 1.12 ± 0.17 for group G2b. There was no statistically significant difference in debonding time between the 2- and 1- bottle adhesive resin cement within the groups G1a and b (p = 0.2914), or between groups G2a b (p = 0.7116). A statistically significant difference (p < 0.05) was found between groups G1a and G2a and b and between groups G1b and G2a and b were SEM analysis showed no changes in the microstructure of the ceramic surface after Er:YAG laser irradiation. CONCLUSION: Zirconia and lithium disilicate restorations can be debonded using Er:YAG lasers in a safe and efficient manner. There is no significant difference in the debonding time between the 2- and 1- bottle adhesive resin cement systems used in this study. CLINICAL SIGNIFICANCE: Retrieving zirconia and lithium disilicate ceramics can be a challenging process when using diamond rotary instruments. ER:YAG lasers may efficiently debond these ceramics from the tooth structure, independent of the bonding process used for bonding them.

8.
J Esthet Restor Dent ; 36(7): 1075-1080, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38716797

RESUMO

STATEMENT OF PROBLEM: Limited evidence is available for the effect of chairside adjustment using rotary cutting instruments on the surface roughness and optical properties of different zirconia types. PURPOSE: To evaluate the effect of simulated adjustments on surface roughness and optical properties of different zirconia types. MATERIALS AND METHODS: Three Partially Stabilized Zirconia (PSZ) types based on mole percent yttria (Y) concentration from the same manufacturer (Katana; Kuraray) were used: 3Y-PSZ, 4Y-PSZ, and 5Y-PSZ. Thirty disk-shaped specimens (Ø14 × 1.2 mm) from different zirconia types (N = 90) were prepared. Specimens were either left without adjustment (NA), adjusted with Dialite ZR finishing and polishing system (Brasseler) (APol), or adjusted with course diamond instruments only (ADia). The specimens were distributed into 9 groups (n = 10): Group 3Y-PSZ/NA, Group 3Y-PSZ/APol, Group 3Y-PSZ/ADia, Group 4Y-PSZ/NA, Group 4Y-PSZ/APol, Group 4Y-PSZ/ADia, Group 5Y-PSZ/NA, Group 5Y-PSZ/APol, and Group 5Y-PSZ/ADia. The surface roughness of specimen was analyzed using an Atomic Force Microscope (AFM) (Bruker's Dimension Icon, Bruker) and Root Means Square (RMS) were recorded (nm). Surface Gloss (SG), Translucency Parameter (TP), and Contrast Ratio (CR) values of all groups were recorded using an integrating sphere spectrophotometer. Statistical analysis was performed using analysis of variance (ANOVA) and Tukey's multiple comparison tests for pairwise comparisons at p < 0.05 and 95% confidence interval. RESULTS: APol had no effect on the surface roughness (p = 0.88) while ADia had a significant negative effect (p < 0.05) despite the type of zirconia. Out of the three testes optical properties, only SG was negatively affected by ADia for all types of zirconia (p < 0.05). The two adjustment types did not affect the TP of all the tested zirconia (p = 0.91). The CR was not affected by the tested adjustments for all zirconia types (p = 0.726). CONCLUSION: Proper zirconia adjustment following a sequence of burs and polishers can maintain acceptable roughness and optical properties. Adjustment of zirconia with rough diamond can lead to deleterious effects and should be avoided. CLINICAL SIGNIFICANCE: Chairside adjustment of zirconia could lead to rougher surface and unpredictable changes of surface gloss. Therefore, zirconia adjustment should be minimized to the greatest extent possible and a proper protocol should be followed if had to be done.


Assuntos
Propriedades de Superfície , Zircônio , Zircônio/química , Teste de Materiais
9.
J Esthet Restor Dent ; 36(1): 164-173, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38173277

RESUMO

AIM: The aim of this randomized, prospective, and clinical multicenter study was to compare the overall clinical performance of two restorative options over a 5-year period: individualized CAD/CAM abutments veneered with a hand-layered ceramic, and prefabricated zirconium dioxide abutments veneered with press ceramic and inserted into a single edentulous gap in the anterior maxilla. MATERIALS AND METHODS: Forty subjects were recruited from two universities: 20 from the University of XX and 20 from the University of XY. Each subject received an implant to restore a single edentulous gap in the maxillary anterior region (14-24 FDI). 20 patients were randomized into each Group. Group A received a one-piece single crown produced from a prefabricated zirconia abutment with pressed ceramic and Group B received an individualized CAD/CAM zirconia abutment with a hand-layered technique. After 5 years, the aesthetic and radiographic parameters were assessed. RESULTS: Group A had four dropouts and one failure, resulting in a 95% survival rate and 95% success rate. Group B had two dropouts and two failures which resulted in a 90% survival rate and 90% success rate. No crestal bone level changes were observed, with a mean DIB of 0.06 mm in Group A and 0.09 mm in Group B. No statistically significant differences were present at baseline, 6 months, 1 year, 3 years, or 5 years for DIB values between time points and groups. Pink aesthetic score/white aesthetic score, Peri-Implant and Crown Index, and Implant Crown Aesthetic Index values were stable over time at all five points for both groups. CONCLUSION: Both implant-supported restorative options represent a valuable treatment option for the restoration of implant crowns in the anterior maxilla. CLINICAL SIGNIFICANCE: In general, the use of ceramic abutments in the anterior zone represents a valuable treatment procedure with both standardized and CAD/CAM individualized abutments and following the recommendations from the respective manufacturer(s).


Assuntos
Cerâmica , Zircônio , Humanos , Estudos Prospectivos , Coroas , Desenho Assistido por Computador , Dente Suporte , Titânio
10.
J Esthet Restor Dent ; 36(4): 673-679, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37921014

RESUMO

STATEMENT OF PROBLEM: Despite the growing utilization of direct intraoral scanners (IOSs) in dentistry, there is a scarcity of research investigating their accuracy, specifically in post and core. Few studies have conducted comprehensive three-dimensional assessments and comparisons of IOSs with the conventional impression technique, particularly in different post space lengths. PURPOSE: The purpose of this in vitro study was to digitally assess the accuracy of direct intraoral scanner (IOS) impressions for different post space lengths, specifically 6, 8, and 10 mm. MATERIALS AND METHODS: A total of 45 typodont teeth (maxillary central incisors) were selected for this study. The teeth underwent endodontic treatment and were divided into three subgroups, each with 15 teeth, based on the desired post space lengths: 6, 8, and 10 mm. Intraoral scans of all specimens were acquired directly using the CEREC Primescan intraoral scanners by two trained examiners. The obtained scan data were compared with conventional impressions obtained using light and heavy bodies of polyvinyl siloxane (PVS). As a control, the conventional impressions were subsequently scanned using an inEos X5a lab scanner. The accuracy of the digital scans was evaluated in the coronal, middle, and apical thirds using the Geomagic Control X software. Statistical analysis was performed using Bonferroni Post-hoc and One-way ANOVA tests to analyze the data. RESULTS: The overall mean root mean square (RMS) deviations for the different post lengths across the three thirds groups were 58, 81, and 101 µm for the 6, 8, and 10 mm subgroups, respectively. There were no statistically significant differences in the accuracy of the coronal and middle thirds among all subgroups (p > 0.5). However, in the apical third, the 10 mm subgroup exhibited a significantly lower accuracy (163 µm) compared to the 6 mm (96 µm) and 8 mm (131 µm) subgroups (p < 0.05). These results suggest that while the accuracy of intraoral scans using direct IOS impressions was consistent in the coronal and middle thirds regardless of the post length, there was a noticeable decrease in accuracy in the apical third, particularly with longer post lengths. CONCLUSION: Considering the limitations of this in vitro study, chairside direct IOS impressions offer a viable and clinically acceptable alternative to the conventional impression technique for post space lengths of 6 and 8 mm. However, as the post space length preparation increases, the accuracy of IOS decreases. CLINICAL SIGNIFICANCE: The Chairside direct IOS enables expedited and efficient digital impression capture within the root canal, ensuring acceptable accuracy for intracanal post length preparation of up to 8 mm.


Assuntos
Técnica de Moldagem Odontológica , Imageamento Tridimensional , Desenho Assistido por Computador , Modelos Dentários , Incisivo
11.
J Esthet Restor Dent ; 36(4): 566-572, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37882153

RESUMO

The reverse impression method involves the extraoral digitalization of the interim implant-supported prostheses and intraoral digitalization of antagonist arch and maxillomandibular relationship. This technique allows the fabrication of implant-supported prostheses by using a complete-digital workflow. The scan analogs make the reverse impression method feasible. However, this method may not be recommended if the interim polymethyl methacrylate prosthesis does not have passive fit. The present manuscript describes an altered reverse impression technique that involves the extraoral digitalization of a conventional verification jig, which has attached scan analogs. With this technique modification, the implant positions captured using the verification jig are used to obtain the virtual definitive implant cast and fabricate the definitive implant-supported prosthesis.


Assuntos
Implantes Dentários , Fluxo de Trabalho , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante/métodos , Desenho Assistido por Computador
12.
J Esthet Restor Dent ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38757761

RESUMO

OBJECTIVES: To provide an overview of the current artificial intelligence (AI) based applications for assisting digital data acquisition and implant planning procedures. OVERVIEW: A review of the main AI-based applications integrated into digital data acquisitions technologies (facial scanners (FS), intraoral scanners (IOSs), cone beam computed tomography (CBCT) devices, and jaw trackers) and computer-aided static implant planning programs are provided. CONCLUSIONS: The main AI-based application integrated in some FS's programs involves the automatic alignment of facial and intraoral scans for virtual patient integration. The AI-based applications integrated into IOSs programs include scan cleaning, assist scanning, and automatic alignment between the implant scan body with its corresponding CAD object while scanning. The more frequently AI-based applications integrated into the programs of CBCT units involve positioning assistant, noise and artifacts reduction, structures identification and segmentation, airway analysis, and alignment of facial, intraoral, and CBCT scans. Some computer-aided static implant planning programs include patient's digital files, identification, labeling, and segmentation of anatomical structures, mandibular nerve tracing, automatic implant placement, and surgical implant guide design.

13.
J Esthet Restor Dent ; 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39103316

RESUMO

OBJECTIVE: To assess the 2D and 3D natural symmetry of the maxillary incisors. MATERIALS AND METHODS: Maxillary alginate impressions were taken of 59 young adult volunteers. Gender, orthodontic treatment history, and dominant hand were collected. For 2D analysis, a digital caliper was used for measurements on maxillary casts. For 3D analysis, the casts were scanned using a lab scanner, and the labial surface symmetry of contralateral incisors was evaluated. Mann-Whitney tests and Student's t-test were performed, α = 0.05. RESULTS: Results indicated a lack of identical lengths among contralateral central or lateral incisors, with minimal occurrences of identical width measurements. 68% of central incisors and 73% of lateral incisors showed differences in length exceeding 0.2 mm. Central incisors showed more similarities than lateral incisors in width, with 61% central incisors and 47% lateral incisors having differences under 0.2 mm. The differences between highly asymmetrical contralateral teeth are situated at the transitional lines. The influence of sexual dimorphism, orthodontic factors, and the dominant hand on incisors' symmetry was not statistically significant. CONCLUSIONS: 2D and 3D symmetry of the natural maxillary incisors are rare. 3D symmetry remains consistent across orthodontic treatment status, gender, and dominant hand, suggesting its independence from such parameters. CLINICAL SIGNIFICANCE: To achieve a natural and aesthetic smile rehabilitation, the symmetry of the maxillary incisors must be well understood. In our study, 2D and 3D symmetry of the maxillary incisors occurred rarely, but central incisors showed more similarities than lateral incisors in width, with differences under 0.2 mm. On the other hand, differences between highly asymmetrical contralateral teeth are situated at the transitional lines. These conclusions should be included in further computer-assisted three-dimensional smile designs.

14.
J Esthet Restor Dent ; 36(1): 174-185, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36866726

RESUMO

OBJECTIVE: This article highlights a CAD/CAM complete-mouth rehabilitation in an 82-year-old patient by means of a complete maxillary prosthesis and mandibular implant- and tooth-supported fixed restorations made from multilayered zirconia. CLINICAL CONSIDERATIONS: Comprehensive complete-mouth rehabilitations in elderly patients with adaptation of the occlusal vertical dimension (OVD) often present particular challenges. This applies especially when exacting functional and esthetic requirements are to be met and the treatment should not cause the patient too much effort, still ensuring the highest level of quality and efficiency and a low intervention rate. CONCLUSION: The digital approach used for the present patient allowed for an efficient treatment procedure, facilitated virtual evaluations using a face-scan, and enhanced the predictability of the prosthodontic outcome. The approach enabled some steps required in the conventional protocol to be omitted, resulting in a straightforward clinical treatment with minimal strain on the patient. CLINICAL SIGNIFICANCE: Because of the comprehensive recording of extraoral and intraoral data, for example with a facial scanner, it was possible to transfer a digital replica of the patient to the dental laboratory technician. With this protocol, many steps can be performed in the absence of the real patient.


Assuntos
Prótese Dentária Fixada por Implante , Reabilitação Bucal , Idoso de 80 Anos ou mais , Humanos , Desenho Assistido por Computador , Planejamento de Prótese Dentária/métodos , Prótese Dentária Fixada por Implante/métodos , Prótese Total , Zircônio
15.
Gerodontology ; 41(2): 305-309, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38422399

RESUMO

OBJECTIVE: To describe the clinical procedures of complete denture set fabrication in three appointments. BACKGROUND: Simplified approaches have proven not to be inferior to conventional ones in terms of quality, patient satisfaction and masticatory ability. MATERIALS AND METHODS: The patient was a 77-year-old edentulous adult with mobility impairment seeking dental rehabilitation in a small number of appointments due to commuting difficulties. RESULTS: A set of complete dentures was delivered within three appointments. The second appointment was dedicated to set-up trial due to the patient's aesthetic demands. CONCLUSION: Under certain circumstances and after a thorough study of each case, dental clinicians may propose the fabrication of complete dentures in a three-appointment protocol incorporating a set-up trial session.


Assuntos
Planejamento de Dentadura , Prótese Total , Humanos , Idoso , Boca Edêntula/reabilitação , Limitação da Mobilidade , Masculino , Feminino , Agendamento de Consultas , Técnica de Moldagem Odontológica
16.
BMC Oral Health ; 24(1): 303, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38439020

RESUMO

BACKGROUND: The present systematic review and meta-analysis investigated the available evidence about the adherence of Candida Albicans to the digitally-fabricated acrylic resins (both milled and 3D-printed) compared to the conventional heat-polymerized acrylic resins. METHODS: This study followed the guidelines of the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA). A comprehensive search of online databases/search tools (Web of Science, Scopus, PubMed, Ovid, and Google Scholar) was conducted for all relevant studies published up until May 29, 2023. Only in-vitro studies comparing the adherence of Candida albicans to the digital and conventional acrylic resins were included. The quantitative analyses were performed using RevMan v5.3 software. RESULTS: Fourteen studies were included, 11 of which were meta-analyzed based on Colony Forming Unit (CFU) and Optical Density (OD) outcome measures. The pooled data revealed significantly lower candida colonization on the milled digitally-fabricated compared to the heat-polymerized conventionally-fabricated acrylic resin materials (MD = - 0.36; 95%CI = - 0.69, - 0.03; P = 0.03 and MD = - 0.04; 95%CI = - 0.06, - 0.01; P = 0.0008; as measured by CFU and OD respectively). However, no differences were found in the adhesion of Candida albicans between the 3D-printed digitally-fabricated compared to the heat-polymerized conventionally-fabricated acrylic resin materials (CFU: P = 0.11, and OD: P = 0.20). CONCLUSION: The available evidence suggests that candida is less likely to adhere to the milled digitally-fabricated acrylic resins compared to the conventional ones.


Assuntos
Resinas Acrílicas , Candida albicans , Candida albicans/fisiologia , Bases de Dados Factuais
17.
BMC Oral Health ; 24(1): 123, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38263141

RESUMO

BACKGROUND: Developing competency in removable prosthodontics (RP) is challenging for undergraduate dental students because it involves threshold concepts and tacit knowledge. Understanding this process can enhance learning and professional development in RP. The objective of this study was to identify the barriers hindering knowledge (threshold concept) and skill (tacit knowledge) development, and to propose strategies for achieving RP competency. METHODS: Adopting critical theory, quantitative and qualitative approaches were implemented. The participants were third- to sixth-year dental students and recent dental school graduates. An online questionnaire was used to investigate the knowledge and skills required for achieving RP competency and barriers to RP competency development. Four focus groups were conducted to gather in-depth information. The data was analyzed using descriptive statistics and thematic analysis. RESULTS: A total of 322 respondents completed the questionnaire (67% response rate), and 26 of them participated in focus group interviews. The four threshold concepts to achieve RP competency were the basic principles of RP, removable partial denture design, occlusion, and dental materials. The two main tacit knowledges were impression making and material handling skills. The curriculum should integrate strategies to assist dental students in overcoming intrinsic barriers such as self-experience, revision, and spatial-temporal relationship, along with extrinsic factors such as clinical correlations of content, discussions, and immediate feedback. CONCLUSIONS: Threshold concepts and tacit knowledge in RP for undergraduate dental students have been proposed The strategies to overcome barriers comprise intrinsic and extrinsic factors that include the adoption of experiential learning. This study suggests effective teaching methods and learning strategies to maximize student learning and RP competency development when designing the undergraduate RP curriculum in dental education.


Assuntos
Prostodontia , Estudantes de Odontologia , Humanos , Currículo , Assistência Odontológica , Oclusão Dentária
18.
BMC Oral Health ; 24(1): 38, 2024 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-38185744

RESUMO

BACKGROUND: Various methods can be used for creating zirconia dental restorations, including 3-dimensional (3D) printing and computer-aided design/ computer-aided manufacturing (CAD/CAM) milling. The fused deposition modeling (FDM) printing method for zirconia presents numerous advantages, albeit research on the mechanical properties of these materials and resultant restorations remains scarce. Such developments are undeniably intriguing and warrant further investigation. The objective of the present study was to evaluate the impact of the sintering firing cycle (Conventional vs. Speed sintering) on the flexural strength, flexural modulus, and Vickers Microhardness of milled vs. FDM printed zirconia. METHODS: A total of 60 bars (2 × 5 × 27 mm) were fabricated for flexural strength testing, along with 40 discs (12 × 1.5 mm) for Vickers microhardness testing. Half of the specimens underwent conventional sintering, while the other half underwent a speed sintering cycle. The flexural strength and modulus were determined by a three-point bending test in a universal testing machine. The microhardness of the specimens was evaluated using a Vickers microhardness tester. Statistical analysis was performed using a two-way ANOVA test with a post-hoc Tukey test (p < 0.05). RESULTS: CAD/CAM milled zirconia had significantly higher flexural strength and modulus than FDM-printed zirconia. The sintering process did not significantly affect the flexural strength or modulus of milled or FDM-printed zirconia. The milled speed sintering group had significantly higher values in the Vickers microhardness test compared to the other groups. CONCLUSIONS: The mechanical properties of FDM-printed zirconia specimens were not found to be comparable to those of milled zirconia. Speed sintering cycle may produce milled zirconia restorations with similar flexural strength and modulus to conventional sintering, and even higher Vickers Microhardness values.


Assuntos
Desenho Assistido por Computador , Resistência à Flexão , Humanos , Análise de Variância , Impressão Tridimensional
19.
BMC Oral Health ; 24(1): 54, 2024 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-38195442

RESUMO

BACKGROUND: The effectiveness of newly developed elastomeric polymer hybrid siloxane (PVES), which combines the properties of polyethylene (PE) and polyvinyl siloxane (PVS) elastomers, has been a subject of interest in recent studies. This study aimed to assess the physical properties of hybrid PVES materials by analyzing existing data from recent studies on this topic. METHODS: A systematic literature search was conducted to retrieve peer-reviewed articles published up to February 5, 2023. The population, intervention, comparison, and pertinent outcomes were specified under the PICO framework. The primary data analysis was performed in Microsoft Excel, while statistical analysis used Meta-Essentials. RESULTS: Of the 1152 articles assessed, 14 met the inclusion criteria. The meta-analysis of the selected studies indicated that polyether (PE) and polyvinyl siloxane (PVS) were highly correlated (two-tailed p-values of 0.000 and 0.001, respectively) with the improved tensile strength of vinyl polyether siloxane (PVES) with a significantly positive effect size. Similarly, the hydrophilic characteristics of PVES were significantly improved compared to those of PE and PVS. PE was a significant contributor to the hydrophilic characteristics of PVES, with a two-tailed p-value of 0.000. The effect size was highly positive for hydrophilicity but showed high heterogeneity. It was also observed that the dimensional accuracy of PVES was comparable to those of PE and PVS, with no statistically significant differences among the three materials. CONCLUSIONS: PVES showed promising features, with improved tensile strength and hydrophilic characteristics compared to those of PE and PVS.


Assuntos
Polietileno , Siloxanas , Humanos , Elastômeros , Pais
20.
BMC Oral Health ; 24(1): 310, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443879

RESUMO

BACKGROUND: Rehabilitation of the anterior area when the mesio-distal space is reduced is a challenge for the clinician, due to the patient's anatomical limitations and aesthetic requirements. Narrow Diameter Implants (NDI) are an option of treatment when the standard diameter implant is not possible, but the evidence is scarce. This prospective clinical study aims to analyze the formation of the tooth-implant papilla between the implant and the adjacent natural tooth in the maxillary lateral incisors and mandibular incisors. METHODS: A total of 40 patients treated with NDI, of titanium-zirconium (Ti-Zr) alloy i.e., 2.9 mm Test Group (TG) and 3.3 mm Control Group (CG), were included. The mesiodistal distance between the adjacent natural teeth was used for implant selection, maintaining 1.5 mm between the fixation and the adjacent tooth. Clinical assessment was performed by a clinical examiner at 6 and 12 months after the final prosthesis. The primary variable was the Jemt Papillary Index. Also, implant survival rate (SR), complications, Implant Stability Quotient (ISQ), and patient-reported outcomes measures (PROMs) such as aesthetics, chewing, phonation, comfort, and self-esteem were analyzed. RESULTS: A significant amount of papilla filling was observed concerning the baseline, with a trend towards more formation of the papilla in the TG, with a JPI score of 3. No significant differences were observed between the two groups regarding implant SR, clinical parameters, and complications. In terms of PROMs, a higher satisfaction in the TG was observed, with significant intergroup differences for aesthetics, comfort, self-esteem, and primary stability ISQ (TG: 59.05 (SD: 5.4) vs. CG: 51.55 (SD: 5.7)). CONCLUSIONS: The 2.9 mm diameter Ti-Zr implants achieved a formation of papilla similar to 3.3 mm implants in the anterior region at 12 months of follow-up after the final prosthetic restoration. The use of Ti-Zr implants with a diameter of 2.9 mm to rehabilitate single teeth in areas of the anterior region, where the mesiodistal distance is limited, showed favorable clinical results and a high degree of satisfaction during 1 year of observation similar to 3.3 mm dental implants. TRIAL REGISTRATION: This study was retrospectively registered in ClinicalTrials.gov with the number NCT05642520, dated 18/11/2022.


Assuntos
Implantes Dentários , Titânio , Humanos , Estudos Prospectivos , Projetos de Pesquisa , Zircônio
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa