1.
Blood Press ; 32(1): 2274595, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37885101

RESUMO

OBJECTIVE: 24-hour ambulatory blood pressure monitoring (24ABPM) is state of the art in out-of-office blood pressure (BP) monitoring. Due to discomfort and technical limitations related to cuff-based 24ABPM devices, methods for non-invasive and continuous estimation of BP without the need for a cuff have gained interest. The main aims of the present study were to compare accuracy of a pulse arrival time (PAT) based BP-model and user acceptability of a prototype cuffless multi-sensor device (cuffless device), developed by Aidee Health AS, with a conventional cuff-based oscillometric device (ReferenceBP) during 24ABPM. METHODS: Ninety-five normotensive and hypertensive adults underwent simultaneous 24ABPM with the cuffless device on the chest and a conventional cuff-based oscillometric device on the non-dominant arm. PAT was calculated using the electrocardiogram (ECG) and photoplethysmography (PPG) sensors incorporated in the chest-worn device. The cuffless device recorded continuously, while ReferenceBP measurements were taken every 20 minutes during daytime and every 30 minutes during nighttime. Two-minute PAT-based BP predictions corresponding to the ReferenceBP measurements were compared with ReferenceBP measurements using paired t-tests, bias, and limits of agreement. RESULTS: Mean (SD) of ReferenceBP compared to PAT-based daytime and nighttime systolic BP (SBP) were 129.7 (13.8) mmHg versus 133.6 (20.9) mmHg and 113.1 (16.5) mmHg versus 131.9 (23.4) mmHg. Ninety-five % limits of agreements were [-26.7, 34.6 mmHg] and [-20.9, 58.4 mmHg] for daytime and nighttime SBP respectively. The cuffless device was reported to be significantly more comfortable and less disturbing than the ReferenceBP device during 24ABPM. CONCLUSIONS: In the present study, we demonstrated that a general PAT-based BP model had unsatisfactory agreement with ambulatory BP during 24ABPM, especially during nighttime. If sufficient accuracy can be achieved, cuffless BP devices have promising potential for clinical assessment of BP due to the opportunities provided by continuous BP measurements during real-life conditions and high user acceptability.


What is the context?Hypertension is a major risk factor for cardiovascular and cerebrovascular end-organ damage, morbidity, and mortality world-wide.Accurate measurement of blood pressure is essential for the diagnosis and management of hypertension.What is new?Cuffless blood pressure devices that allow measurement of blood pressure without a pressure cuff is a promising and novel method of blood pressure estimation.The objective of this study is to assess whether pulse arrival time alone can be used to estimate blood pressure accurately during 24-hour ambulatory blood pressure monitoring, using a prototype cuffless device placed on the chest.Our analysis shows that a general model based on pulse arrival time overestimated ambulatory blood pressure, especially during nighttime.User acceptability was higher with the cuffless device compared to a conventional cuff-based oscillometric device during 24-hour ambulatory blood pressure monitoring.What is the impact?This study provides further evidence that accurate blood pressure estimations cannot be achieved by using pulse arrival time alone as a surrogate for blood pressure measurements.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Hipertensão , Adulto , Humanos , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Hipertensão/diagnóstico , Frequência Cardíaca , Análise de Onda de Pulso/métodos
2.
Sensors (Basel) ; 22(4)2022 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-35214582

RESUMO

This paper proposes a novel method for physical fatigue assessment that can be applied in wearable systems, by utilizing a set of real-time measurable cardiovascular parameters. Daylength measurements, including a morning test set, physical exercise during the day, and an afternoon test set were conducted on 16 healthy subjects (8 female and 8 male). To analyze cardiovascular parameters for physical fatigue assessment, electrocardiography, pulse wave and blood pressure were measured during the test sets. The fatigue assessment questionnaire score, reaction time, countermovement jump height and hand grip strength were also measured and used as reference parameters. This study demonstrates that (i) the compiled test battery can selectively assess the rested vs. physically-fatigued states; (ii) the obtained linear support-vector machine, trained using the heart rate variability based parameter (F-score 0.842, accuracy 0.813) and pulse arrival time based parameter (F-score 0.875, accuracy 0.875) shows a promising ability to classify between the physically mildly fatigued and significantly fatigued states. Despite the somewhat limited study group size, the results of the study are unique and provide a significant advancement on the existing physical fatigue assessment methods towards a personalized and continuous real-time fatigue monitoring system with wearable sensors.


Assuntos
Força da Mão , Dispositivos Eletrônicos Vestíveis , Fadiga/diagnóstico , Retroalimentação , Feminino , Frequência Cardíaca , Humanos , Masculino
3.
Sensors (Basel) ; 21(21)2021 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-34770641

RESUMO

The present study aims to develop and validate a cuffless method for blood pressure continuous measurement through a wearable device. The goal is achieved according to the time-delay method, with the guiding principle of the time relation it takes for a blood volume to travel from the heart to a peripheral site. Inversely proportional to the blood pressure, this time relation is obtained as the time occurring between the R peak of the electrocardiographic signal and a marker point on the photoplethysmographic wave. Such physiological signals are recorded by using L.I.F.E. Italia's wearable device, made of a sensorized shirt and wristband. A linear regression model is implemented to estimate the corresponding blood pressure variations from the obtained time-delay and other features of the photoplethysmographic wave. Then, according to the international standards, the model performance is assessed, comparing the estimates with the measurements provided by a certified digital sphygmomanometer. According to the standards, the results obtained during this study are notable, with 85% of the errors lower than 10 mmHg and a mean absolute error lower than 7 mmHg. In conclusion, this study suggests a time-delay method for continuous blood pressure estimates with good performance, compared with a reference device based on the oscillometric technique.


Assuntos
Fotopletismografia , Dispositivos Eletrônicos Vestíveis , Pressão Sanguínea , Determinação da Pressão Arterial , Análise de Onda de Pulso , Esfigmomanômetros
4.
Sensors (Basel) ; 21(16)2021 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-34451035

RESUMO

In standard critical care practice, cuff sphygmomanometry is widely used for intermittent blood pressure (BP) measurements. However, cuff devices offer ample possibility of modulating blood flow and pulse propagation along the artery. We explore underutilized arrangements of sensors involving cuff devices which could be of use in critical care to reveal additional information on compensatory mechanisms. In our previous work, we analyzed the response of the vasculature to occlusion perturbations by means of observations obtained non-invasively. In this study, our aim is to (1) acquire additional insights by means of invasive measurements and (2) based on these insights, further develop cuff-based measurement strategies. Invasive BP experimental data is collected downstream from the cuff in two patients monitored in the OR. It is found that highly dynamic processes occur in the distal arm during cuff inflation. Mean arterial pressure increases in the distal artery by 20 mmHg, leading to a decrease in pulse transit time by 20 ms. Previous characterizations neglected such distal vasculature effects. A model is developed to reproduce the observed behaviors and to provide a possible explanation of the factors that influence the distal arm mechanisms. We apply the new findings to further develop measurement strategies aimed at acquiring information on pulse arrival time vs. BP calibration, artery compliance, peripheral resistance, artery-vein interaction.


Assuntos
Determinação da Pressão Arterial , Análise de Onda de Pulso , Artérias , Pressão Sanguínea , Frequência Cardíaca , Humanos
5.
Clin Exp Hypertens ; 42(6): 512-518, 2020 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-31941385

RESUMO

OBJECTIVE: In recent times, new methods of blood pressure measurements have been introduced, including cuffless blood pressure (BP) measurement device using pulse transit time (PTT) for calculation of BP values. However, it is still unknown how values obtained with a new cuffless device compare with standard ambulatory measurements in children. The main aim of the study was to investigate whether BP values measured by a cuffless PTT device are comparable with measurements by a standard upper arm cuff-based BP device. METHODS: Thirty children were prospectively included. Blood pressure measurements using the cuffless device (Somnotouch-NIBP) and cuff-based standard device (Omron 907) were performed simultaneously on the left and right arm. RESULTS: Mean systolic BP of the standard measurements was 123,47 ± 14,91 mmHg and 127,48 ± 15,98 mmHg (p < .001) measured by cuffless method. Mean diastolic BP of the standard ABPM measurements was 66,88 ± 11,86 mmHg and 68,52 ± 12,36 mmHg (p < .001). There were significant positive correlations between standard and cuffless measurements. CONCLUSION: The results show that the created PWV-BP function produces a significant correlation between BP derived from the PWV and the SBP measured by sphygmomanometry. When applying this device in clinical practice, one may keep in mind that the reported mean values over 24 hours, awake and asleep time are not directly interchangeable with cuff-based standard 24-hour BP values. The measured BP values were higher by the new technique. Although differences in SBP between both methods reached values up to 20 mmHg, we think that the development of a cuffless BP monitoring system will provide novel solutions in various medical situations.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Esfigmomanômetros , Adolescente , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/instrumentação , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/normas , Criança , Relógios Circadianos/fisiologia , Eletrocardiografia/métodos , Feminino , Humanos , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Masculino , Fotopletismografia/métodos , Análise de Onda de Pulso/métodos , Esfigmomanômetros/classificação , Esfigmomanômetros/normas
6.
J Synchrotron Radiat ; 25(Pt 1): 26-31, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29271747

RESUMO

The commissioning of a terahertz-field-driven streak camera installed at the free-electron laser (FEL) FLASH at DESY in Hamburg, being able to deliver photon pulse duration as well as arrival time information with ∼10 fs resolution for each single XUV FEL pulse, is reported. Pulse durations between 300 fs and <15 fs have been measured for different FLASH FEL settings. A comparison between the XUV pulse arrival time and the FEL electron bunch arrival time measured at the FLASH linac section exhibits a correlation width of 20 fs r.m.s., thus demonstrating the excellent operation stability of FLASH. In addition, the terahertz-streaking setup was operated simultaneously to an alternative method to determine the FEL pulse duration based on spectral analysis. FLASH pulse duration derived from simple spectral analysis is in good agreement with that from terahertz-streaking measurement.

7.
Sensors (Basel) ; 17(1)2017 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-28098831

RESUMO

Automatic detection of ectopic beats has become a thoroughly researched topic, with literature providing manifold proposals typically incorporating morphological analysis of the electrocardiogram (ECG). Although being well understood, its utilization is often neglected, especially in practical monitoring situations like online evaluation of signals acquired in wearable sensors. Continuous blood pressure estimation based on pulse wave velocity considerations is a prominent example, which depends on careful fiducial point extraction and is therefore seriously affected during periods of increased occurring extrasystoles. In the scope of this work, a novel ectopic beat discriminator with low computational complexity has been developed, which takes advantage of multimodal features derived from ECG and pulse wave relating measurements, thereby providing additional information on the underlying cardiac activity. Moreover, the blood pressure estimations' vulnerability towards ectopic beats is closely examined on records drawn from the Physionet database as well as signals recorded in a small field study conducted in a geriatric facility for the elderly. It turns out that a reliable extrasystole identification is essential to unsupervised blood pressure estimation, having a significant impact on the overall accuracy. The proposed method further convinces by its applicability to battery driven hardware systems with limited processing power and is a favorable choice when access to multimodal signal features is given anyway.


Assuntos
Análise de Onda de Pulso , Algoritmos , Pressão Sanguínea , Determinação da Pressão Arterial , Eletrocardiografia , Humanos , Processamento de Sinais Assistido por Computador , Dispositivos Eletrônicos Vestíveis
8.
J Med Syst ; 40(9): 195, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27447469

RESUMO

Ambulatory blood pressure monitoring (ABPM) has become an essential tool in the diagnosis and management of hypertension. Current standard ABPM devices use an oscillometric cuff-based method which can cause physical discomfort to the patients with repeated inflations and deflations, especially during nighttime leading to sleep disturbance. The ability to measure ambulatory BP accurately and comfortably without a cuff would be attractive. This study validated the accuracy of a cuff-less approach for ABPM using pulse arrival time (PAT) measurements on both healthy and hypertensive subjects for potential use in hypertensive management, which is the first of its kind. The wearable cuff-less device was evaluated against a standard cuff-based device on 24 subjects of which 15 have known hypertension. BP measurements were taken from each subject over a 24-h period by the cuff-less and cuff-based devices every 15 to 30 minutes during daily activities. Mean BP of each subject during daytime, nighttime and over 24-h were calculated. Agreement between mean nighttime systolic BP (SBP) and diastolic (DBP) measured by the two devices evaluated using Bland-Altman plot were -1.4 ± 6.6 and 0.4 ± 6.7 mmHg, respectively. Receiver operator characteristics (ROC) statistics was used to assess the diagnostic accuracy of the cuff-less approach in the detection of BP above the hypertension threshold during nighttime (>120/70 mmHg). The area under ROC curves were 0.975/0.79 for nighttime. The results suggest that PAT-based approach is accurate and promising for ABPM without the issue of sleep disturbances associated with cuff-based devices.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/instrumentação , Monitorização Ambulatorial da Pressão Arterial/normas , Hipertensão/diagnóstico , Adulto , Idoso , Humanos , Pessoa de Meia-Idade
9.
Physiol Meas ; 45(3)2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38387047

RESUMO

Objective.Wearable devices that measure vital signals using photoplethysmography are becoming more commonplace. To reduce battery consumption, computational complexity, memory footprint or transmission bandwidth, companies of commercial wearable technologies are often looking to minimize the sampling frequency of the measured vital signals. One such vital signal of interest is the pulse arrival time (PAT), which is an indicator of blood pressure. To leverage this non-invasive and non-intrusive measurement data for use in clinical decision making, the accuracy of obtained PAT-parameters needs to increase in lower sampling frequency recordings. The aim of this paper is to develop a new strategy to estimate PAT at sampling frequencies up to 25 Hertz.Approach.The method applies template matching to leverage the random nature of sampling time and expected change in the PAT.Main results.The algorithm was tested on a publicly available dataset from 22 healthy volunteers, under sitting, walking and running conditions. The method significantly reduces both the mean and the standard deviation of the error when going to lower sampling frequencies by an average of 16.6% and 20.2%, respectively. Looking only at the sitting position, this reduction is even larger, increasing to an average of 22.2% and 48.8%, respectively.Significance.This new method shows promise in allowing more accurate estimation of PAT even in lower frequency recordings.


Assuntos
Determinação da Pressão Arterial , Dispositivos Eletrônicos Vestíveis , Humanos , Determinação da Pressão Arterial/métodos , Pressão Sanguínea/fisiologia , Frequência Cardíaca , Fotopletismografia/métodos
10.
Physiol Meas ; 45(5)2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38688296

RESUMO

Background.Non-invasive continuous blood pressure (BP) monitoring is of longstanding interest in various cardiovascular scenarios. In this context, pulse arrival time (PAT), i.e., a surrogate parameter for systolic BP (change), became very popular recently, especially in the context of cuffless BP measurement and dedicated lifestyle interventions. Nevertheless, there is also understandable doubt on its reliability in uncontrolled and mobile settings.Objective.The aim of this work is therefore the investigation whether PAT follows oscillometric systolic BP readings during moderate interventions by physical or mental activity using a medical grade handheld device for non-invasive PAT assessment.Approach.A study was conducted featuring an experimental group performing a physical and a mental task, and a control group. Oscillometric BP and PAT were assessed at baseline and after each intervention. Interventions were selected randomly but then performed sequentially in a counterbalanced order. Multivariate analyses of variance were used to test within-subject and between-subject effects for the dependent variables, followed by univariate analyses for post-hoc testing. Furthermore, correlation analysis was performed to assess the association of intervention effects between BP and PAT.Mainresults.The study included 51 subjects (31 females). Multivariate analysis of variances showed that effects in BP, heart rate, PAT and pulse wave parameters were consistent and significantly different between experimental and control groups. After physical activity, heart rate and systolic BP increased significantly whereas PAT decreased significantly. Mental activity leads to a decrease in systolic BP at stable heart rate. Pulse wave parameters follow accordingly by an increase of PAT and mainly unchanged pulse wave analysis features due to constant heart rate. Finally, also the control group behaviour was accurately registered by the PAT method compared to oscillometric cuff. Correlation analyses revealed significant negative associations between changes of systolic BP and changes of PAT from baseline to the physical task (-0.33 [-0.63, 0.01],p< 0.048), and from physical to mental task (-0.51 [-0.77, -0.14],p= 0.001), but not for baseline to mental task (-0.12 [-0,43,0,20],p= 0.50) in the experimental group.Significance.PAT and the used digital, handheld device proved to register changes in BP and heart rate reliably compared to oscillometric measurements during intervention. Therefore, it might add benefit to future mobile health solutions to support BP management by tracking relative, not absolute, BP changes during non-pharmacological interventions.


Assuntos
Determinação da Pressão Arterial , Pressão Sanguínea , Oscilometria , Humanos , Feminino , Masculino , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Adulto , Sístole/fisiologia , Pessoa de Meia-Idade , Frequência Cardíaca/fisiologia , Exercício Físico , Fatores de Tempo
11.
Physiol Meas ; 45(7)2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-38986482

RESUMO

Objective.Cardiac Index (CI) is a key physiologic parameter to ensure end organ perfusion in the pediatric intensive care unit (PICU). Determination of CI requires invasive cardiac measurements and is not routinely done at the PICU bedside. To date, there is no gold standard non-invasive means to determine CI. This study aims to use a novel non-invasive methodology, based on routine continuous physiologic data, called Pulse Arrival Time (PAT) as a surrogate for CI in patients with normal Ejection Fraction (EF).Approach.Electrocardiogram (ECG) and photoplethysmogram (PPG) signals were collected from beside monitors at a sampling frequency of 250 samples per second. Continuous PAT, derived from the ECG and PPG waveforms was averaged per patient. Pearson's correlation coefficient was calculated between PAT and CI, PAT and heart rate (HR), and PAT and EF.Main Results.Twenty patients underwent right heart cardiac catheterization. The mean age of patients was 11.7 ± 5.4 years old, ranging from 11 months old to 19 years old, the median age was 13.4 years old. HR in this cohort was 93.8 ± 17.0 beats per minute. The average EF was 54.4 ± 9.6%. The average CI was 3.51 ± 0.72 l min-1m-2, with ranging from 2.6 to 4.77 l min-1m-2. The average PAT was 0.31 ± 0.12 s. Pearson correlation analysis showed a positive correlation between PAT and CI (0.57,p< 0.01). Pearson correlation between HR and CI, and correlation between EF and CI was 0.22 (p= 0.35) and 0.03 (p= 0.23) respectively. The correlation between PAT, when indexed by HR (i.e. PAT × HR), and CI minimally improved to 0.58 (p< 0.01).Significance.This pilot study demonstrates that PAT may serve as a valuable surrogate marker for CI at the bedside, as a non-invasive and continuous modality in the PICU. The use of PAT in clinical practice remains to be thoroughly investigated.


Assuntos
Transplante de Coração , Volume Sistólico , Humanos , Criança , Adolescente , Pré-Escolar , Masculino , Feminino , Lactente , Volume Sistólico/fisiologia , Adulto Jovem , Frequência Cardíaca/fisiologia , Eletrocardiografia , Pulso Arterial , Fotopletismografia , Fatores de Tempo
12.
Biosensors (Basel) ; 14(4)2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38667198

RESUMO

Wearable health devices (WHDs) are rapidly gaining ground in the biomedical field due to their ability to monitor the individual physiological state in everyday life scenarios, while providing a comfortable wear experience. This study introduces a novel wearable biomedical device capable of synchronously acquiring electrocardiographic (ECG), photoplethysmographic (PPG), galvanic skin response (GSR) and motion signals. The device has been specifically designed to be worn on a finger, enabling the acquisition of all biosignals directly on the fingertips, offering the significant advantage of being very comfortable and easy to be employed by the users. The simultaneous acquisition of different biosignals allows the extraction of important physiological indices, such as heart rate (HR) and its variability (HRV), pulse arrival time (PAT), GSR level, blood oxygenation level (SpO2), and respiratory rate, as well as motion detection, enabling the assessment of physiological states, together with the detection of potential physical and mental stress conditions. Preliminary measurements have been conducted on healthy subjects using a measurement protocol consisting of resting states (i.e., SUPINE and SIT) alternated with physiological stress conditions (i.e., STAND and WALK). Statistical analyses have been carried out among the distributions of the physiological indices extracted in time, frequency, and information domains, evaluated under different physiological conditions. The results of our analyses demonstrate the capability of the device to detect changes between rest and stress conditions, thereby encouraging its use for assessing individuals' physiological state. Furthermore, the possibility of performing synchronous acquisitions of PPG and ECG signals has allowed us to compare HRV and pulse rate variability (PRV) indices, so as to corroborate the reliability of PRV analysis under stationary physical conditions. Finally, the study confirms the already known limitations of wearable devices during physical activities, suggesting the use of algorithms for motion artifact correction.


Assuntos
Eletrocardiografia , Dedos , Resposta Galvânica da Pele , Frequência Cardíaca , Fotopletismografia , Dispositivos Eletrônicos Vestíveis , Humanos , Monitorização Fisiológica/instrumentação , Processamento de Sinais Assistido por Computador , Masculino , Adulto , Feminino
13.
Stud Health Technol Inform ; 301: 123-124, 2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-37172165

RESUMO

Stress is an increasing burden for our society and related to cardiovascular (CV) parameters and diseases. Effects of mental or physical stress were observed in CV parameters during task completion and recovery. These effects were measured using a novel handheld device, which can be incorporated in mHealth solutions.


Assuntos
Cognição , Pressão Sanguínea
14.
Front Med (Lausanne) ; 10: 1154041, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37138759

RESUMO

Objective: Continuous non-invasive cuffless blood pressure (BP) monitoring may reduce adverse outcomes in hospitalized patients if accuracy is approved. We aimed to investigate accuracy of two different BP prediction models in critically ill intensive care unit (ICU) patients, using a prototype cuffless BP device based on electrocardiogram and photoplethysmography signals. We compared a pulse arrival time (PAT)-based BP model (generalized PAT-based model) derived from a general population cohort to more complex and individualized models (complex individualized models) utilizing other features of the BP sensor signals. Methods: Patients admitted to an ICU with indication of invasive BP monitoring were included. The first half of each patient's data was used to train a subject-specific machine learning model (complex individualized models). The second half was used to estimate BP and test accuracy of both the generalized PAT-based model and the complex individualized models. A total of 7,327 measurements of 15 s epochs were included in pairwise comparisons across 25 patients. Results: The generalized PAT-based model achieved a mean absolute error (SD of errors) of 7.6 (7.2) mmHg, 3.3 (3.1) mmHg and 4.6 (4.4) mmHg for systolic BP, diastolic BP and mean arterial pressure (MAP) respectively. Corresponding results for the complex individualized model were 6.5 (6.7) mmHg, 3.1 (3.0) mmHg and 4.0 (4.0) mmHg. Percentage of absolute errors within 10 mmHg for the generalized model were 77.6, 96.2, and 89.6% for systolic BP, diastolic BP and MAP, respectively. Corresponding results for the individualized model were 83.8, 96.2, and 94.2%. Accuracy was significantly improved when comparing the complex individualized models to the generalized PAT-based model in systolic BP and MAP, but not diastolic BP. Conclusion: A generalized PAT-based model, developed from a different population was not able to accurately track BP changes in critically ill ICU patients. Individually fitted models utilizing other cuffless BP sensor signals significantly improved accuracy, indicating that cuffless BP can be measured non-invasively, but the challenge toward generalizable models remains for future research to resolve.

15.
Hypertension ; 80(3): 534-540, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36458550

RESUMO

Conventional blood pressure (BP) measurement devices based on an inflatable cuff only provide a narrow view of the continuous BP profile. Cuffless BP measuring technologies could permit numerous BP readings throughout daily life and thereby considerably improve the assessment and management of hypertension. Several wearable cuffless BP devices based on pulse wave analysis (applied to a photoplethysmography or tonometry waveform) with or without use of pulse arrival time are now available on the market. The key question is: Can these devices provide accurate measurement of BP? Microsoft Research recently published a complex article describing perhaps the most important and highest resource project to date (Aurora Project) on assessing the accuracy of several pulse wave analysis and pulse wave analysis-pulse arrival time devices. The overall results from 1125 participants were clear-cut negative. The present article motivates and describes emerging cuffless BP devices and then summarizes the Aurora Project. The study methodology and findings are next discussed in the context of regulatory-cleared devices, physiology, and related studies, and the study strengths and limitations are pinpointed thereafter. Finally, the implications of the Aurora Project are briefly stated and recommendations for future work are offered to finally realize the considerable potential of cuffless BP measurement in health care.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Humanos , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Hipertensão/diagnóstico , Esfigmomanômetros , Frequência Cardíaca , Análise de Onda de Pulso/métodos
16.
Front Physiol ; 14: 1172688, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37334047

RESUMO

Blood pressure (BP) surrogates, such as pulse transit time (PTT) or pulse arrival time (PAT), have been intensively explored with the goal of achieving cuffless, continuous, and accurate BP inference. In order to estimate BP, a one-point calibration strategy between PAT and BP is typically used. Recent research focuses on advanced calibration procedures exploiting the cuff inflation process to improve calibration robustness by active and controlled modulation of peripheral PAT, as measured via plethysmograph (PPG) and electrocardiogram (ECG) combination. Such methods require a detailed understanding of the mechanisms behind the vasculature's response to cuff inflation; for this, a model has recently been developed to infer the PAT-BP calibration from measured cuff-induced vasculature changes. The model, while promising, is still preliminary and only partially validated; in-depth analysis and further developments are still needed. Therefore, this work aims to improve our understanding of the cuff-vasculature interaction in this model; we seek to define potential opportunities and to highlight which aspects may require further study. We compare model behaviors with clinical data samples based on a set of observable characteristics relevant for BP inference and calibration. It is found that the observed behaviors are qualitatively well represented with the current simulation model and complexity, with limitations regarding the prediction of the onset of the distal arm dynamics and behavior changes at high cuff pressures. Additionally, a sensitivity analysis of the model's parameter space is conducted to show the factors that influence the characteristics of its observable outputs. It was revealed that easily controllable experimental variables, such as lateral cuff length and inflation rate, have a significant impact on cuff-induced vasculature changes. An interesting dependency between systemic BP and cuff-induced distal PTT change is also found, revealing opportunities for improved methods for BP surrogate calibration. However, validation via patient data shows that this relation does not hold for all patients, indicating required model improvements to be validated in follow up studies. These results provide promising directions to improve the calibration process featuring cuff inflation towards accurate and robust non-invasive blood pressure estimation.

17.
Biomed Eng Lett ; 13(4): 625-636, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37872987

RESUMO

Pulse arrival time (PAT) and PPG morphological features have attracted much interest in cuffless blood pressure (BP) estimation, but their effects are not clearly understood when vascular characteristics are affected by diseases such as diabetes. This work quantitatively analyzes the effect of diabetic disease on the PAT and PPG morphological features-based BP estimation. We selected 112 diabetic patients and 308 non-diabetic subjects from VitalDB, and extracted 16 features including PAT, PPG morphological features, and heart rate. BP estimation performance was statistically compared between groups using linear regression models with several feature sets, and the relative importance of each feature in the optimal feature set was extracted. As a result, the standard deviation of the error and mean absolute error of PAT-based BP estimation were significantly higher in the diabetic group than in the non-diabetic group (p < 0.01). A feature set containing PAT and PPG morphological features achieved the best performance in both groups. However, the relative importance of each feature for BP estimation differed notably between groups. The results indicate that different features are important depending on the vascular characteristics, which could help to construct different models to accommodate specific diseases.

18.
Sleep ; 45(3)2022 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-34965303

RESUMO

STUDY OBJECTIVES: This study was designed to test the utility of cardiovascular responses as markers of potentially different environmental noise disruption effects of wind farm compared to traffic noise exposure during sleep. METHODS: Twenty participants underwent polysomnography. In random order, and at six sound pressure levels from 33 dBA to 48 dBA in 3 dB increments, three types of wind farm and two types of road traffic noise recordings of 20-s duration were played during established N2 or deeper sleep, each separated by 20 s without noise. Each noise sequence also included a no-noise control. Electrocardiogram and finger pulse oximeter recorded pulse wave amplitude changes from the pre-noise onset baseline following each noise exposure and were assessed algorithmically to quantify the magnitude of heart rate and finger vasoconstriction responses to noise exposure. RESULTS: Higher sound pressure levels were more likely to induce drops in pulse wave amplitude. Sound pressure levels as low as 39 dBA evoked a pulse wave amplitude response (Odds ratio [95% confidence interval]; 1.52 [1.15, 2.02]). Wind farm noise with amplitude modulation was less likely to evoke a pulse wave amplitude response than the other noise types, but warrants cautious interpretation given low numbers of replications within each noise type. CONCLUSIONS: These preliminary data support that drops in pulse wave amplitude are a particularly sensitive marker of noise-induced cardiovascular responses during. Larger trials are clearly warranted to further assess relationships between recurrent cardiovascular activation responses to environmental noise and potential long-term health effects.


Assuntos
Ruído , Sono , Eletrocardiografia , Frequência Cardíaca/fisiologia , Humanos , Ruído/efeitos adversos , Polissonografia , Sono/fisiologia
19.
Front Physiol ; 13: 960118, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36699693

RESUMO

The multidimensionality of the stress response has shown the complexity of this phenomenon and therefore the impossibility of finding a unique biomarker among the physiological variables related to stress. An experimental study was designed and performed to guarantee the correct synchronous and concurrent measure of psychometric tests, biochemical variables and physiological features related to acute emotional stress. The population studied corresponds to a group of 120 university students between 20 and 30 years of age, with healthy habits and without a diagnosis of chronic or psychiatric illnesses. Following the protocol of the experimental pilot, each participant reached a relaxing state and a stress state in two sessions of measurement for equivalent periods. Both states are correctly achieved evidenced by the psychometric test results and the biochemical variables. A Stress Reference Scale is proposed based on these two sets of variables. Then, aiming for a non-invasive and continuous approach, the Acute Stress Model correlated to the previous scale is also proposed, supported only by physiological signals. Preliminary results support the feasibility of measuring/quantifying the stress level. Although the results are limited to the population and stimulus type, the procedure and methodological analysis used for the assessment of acute stress in young people can be extrapolated to other populations and types of stress.

20.
Front Physiol ; 13: 863855, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35899026

RESUMO

Introduction: There is a lack of data describing the blood pressure response (BPR) in well-trained individuals. In addition, continuous bio-signal measurements are increasingly investigated to overcome the limitations of intermittent cuff-based BP measurements during exercise testing. Thus, the present study aimed to assess the BPR in well-trained individuals during a cycle ergometer test with a particular focus on the systolic BP (SBP) and to investigate pulse arrival time (PAT) as a continuous surrogate for SBP during exercise testing. Materials and Methods: Eighteen well-trained male cyclists were included (32.4 ± 9.4 years; maximal oxygen uptake 63 ± 10 ml/min/kg) and performed a stepwise lactate threshold test with 5-minute stages, followed by a continuous test to voluntary exhaustion with 1-min increments when cycling on an ergometer. BP was measured with a standard automated exercise BP cuff. PAT was measured continuously with a non-invasive physiological measurements device (IsenseU) and metabolic consumption was measured continuously during both tests. Results: At lactate threshold (281 ± 56 W) and maximal intensity test (403 ± 61 W), SBP increased from resting values of 136 ± 9 mmHg to maximal values of 219 ± 21 mmHg and 231 ± 18 mmHg, respectively. Linear within-participant regression lines between PAT and SBP showed a mean r 2 of 0.81 ± 17. Conclusion: In the present study focusing on the BPR in well-trained individuals, we observed a more exaggerated systolic BPR than in comparable recent studies. Future research should follow up on these findings to clarify the clinical implications of the high BPR in well-trained individuals. In addition, PAT showed strong intra-individual associations, indicating potential use as a surrogate SBP measurement during exercise testing.