Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Magn Reson Med ; 92(5): 2127-2139, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38953429

RESUMO

PURPOSE: To assess the potential for accelerating continuous-wave (CW) T1ρ dispersion measurement with compressed sensing approach via studying the effect that the data reduction has on the ability to detect differences between intact and degenerated articular cartilage with different spin-lock amplitudes and to assess quantitative bias due to acceleration. METHODS: Osteochondral plugs (n = 27, 4 mm diameter) from femur (n = 14) and tibia (n = 13) regions from human cadaver knee joints were obtained from commercial biobank (Science Care, USA) under Ethical permission 134/2015. MRI of specimens was performed at 9.4T with magnetization prepared radial balanced SSFP (bSSFP) readout sequence, and the CWT1ρ relaxation time maps were computed from the measured data. The relaxation time maps were evaluated in the cartilage zones for different acceleration factors. For reference, Osteoarthritis Research Society International (OARSI) grading and biomechanical measurements were performed and correlated with the MRI findings. RESULTS: Four-fold acceleration of CWT1ρ dispersion measurement by compressed sensing approach was feasible without meaningful loss in the sensitivity to osteoarthritic (OA) changes within the articular cartilage. Differences were significant between intact and OA groups in the superficial and transitional zones, and CWT1ρ correlated moderately with the reference measurements (0.3 < r < 0.7). CONCLUSION: CWT1ρ was able to differentiate between intact and OA cartilage even with four-fold acceleration. This indicates that acceleration of CWT1ρ dispersion measurement by compressed sensing approach is feasible with negligible loss in the sensitivity to osteoarthritic changes in articular cartilage.


Assuntos
Cartilagem Articular , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Cartilagem Articular/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Idoso , Feminino , Masculino , Pessoa de Meia-Idade , Processamento de Imagem Assistida por Computador/métodos , Cadáver , Tíbia/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Osteoartrite/diagnóstico por imagem , Algoritmos , Osteoartrite do Joelho/diagnóstico por imagem
2.
Magn Reson Med ; 87(6): 2685-2696, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35037292

RESUMO

PURPOSE: To accelerate the Pointwise Encoding Time Reduction with Radial Acquisition (PETRA) sequence using compressed sensing while preserving the image quality for high-resolution MRI of tissue with ultra-short T2∗ values. METHODS: Compressed sensing was introduced in the PETRA sequence (csPETRA) to accelerate the time-consuming single point acquisition of the k-space center data. Random undersampling was applied to achieve acceleration factors up to Acc = 32. Phantom and in vivo images of the knee joint of six volunteers were measured at 3T using csPETRA sequence with Acc = 4, 8, 12, 16, 24, and 32. Images were compared against fully sampled PETRA data (Acc = 1) for structural similarity and normalized-mean-square-error. Qualitative and semi-quantitative analyses were performed to assess the effect of the acceleration on image artifacts, image quality, and delineation of anatomical structures at the knee. RESULTS: Even at high acceleration factors of Acc = 16 no aliasing artifacts were observed, and the anatomical details were preserved compared with the fully sampled data. The normalized-mean-square-error was less than 1% for Acc = 16, in which single point imaging acquisition time was reduced from 165 to 10 s, reducing the total scan time from 7.8 to 5.2 min. Semi-quantitative analyses suggest that Acc = 16 yields comparable diagnostic quality as the fully sampled data for knee imaging at a scan time of 5.2 min. CONCLUSION: csPETRA allows for ultra-short T2∗ imaging of the knee joint in clinically acceptable scan times while maintaining the image quality of original non-accelerated PETRA sequence.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador/métodos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
3.
Magn Reson Med ; 85(2): 945-952, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32738084

RESUMO

PURPOSE: To develop a novel magnetic resonance elastography (MRE) acquisition using a hybrid radial EPI readout scheme (TURBINE), and to demonstrate its feasibility to obtain wave images and stiffness maps in a phantom and in vivo brain. METHOD: The proposed 3D TURBINE-MRE is based on a spoiled gradient-echo MRE sequence with the EPI readout radially rotating about the phase-encoding axis to sample a full 3D k-space. A polyvinyl chloride phantom and 6 volunteers were scanned on a compact 3T GE scanner with a 32-channel head coil at 80 Hz and 60 Hz external vibration, respectively. For comparison, a standard 2D, multislice, spin-echo (SE) EPI-MRE acquisition was also performed with the same motion encoding and resolution. The TURBINE-MRE images were off-line reconstructed with iterative SENSE algorithm. The regional ROI analysis was performed on the 6 volunteers, and the median stiffness values were compared between SE-EPI-MRE and TURBINE-MRE. RESULTS: The 3D wave-field images and the generated stiffness maps were comparable between TURBINE-MRE and standard SE-EPI-MRE for the phantom and the volunteers. The Bland-Altman plot showed no significant difference in the median regional stiffness values between the two methods. The stiffness measured with the 2 methods had a strong linear relationship with a Pearson correlation coefficient of 0.943. CONCLUSION: We demonstrated the feasibility of the new TURBINE-MRE sequence for acquiring the desired 3D wave-field data and stiffness maps in a phantom and in-vivo brains. This pilot study encourages further exploration of TURBINE-MRE for functional MRE, free-breathing abdominal MRE, and cardiac MRE applications.


Assuntos
Técnicas de Imagem por Elasticidade , Imagem Ecoplanar , Humanos , Imageamento por Ressonância Magnética , Projetos Piloto , Reprodutibilidade dos Testes
4.
Magn Reson Med ; 85(3): 1195-1208, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32924188

RESUMO

PURPOSE: Cardiac MR cine imaging allows accurate and reproducible assessment of cardiac function. However, its long scan time not only limits the spatial and temporal resolutions but is challenging in patients with breath-holding difficulty or non-sinus rhythms. To reduce scan time, we propose a multi-domain convolutional neural network (MD-CNN) for fast reconstruction of highly undersampled radial cine images. METHODS: MD-CNN is a complex-valued network that processes MR data in k-space and image domains via k-space interpolation and image-domain subnetworks for residual artifact suppression. MD-CNN exploits spatio-temporal correlations across timeframes and multi-coil redundancies to enable high acceleration. Radial cine data were prospectively collected in 108 subjects (50 ± 17 y, 72 males) using retrospective-gated acquisition with 80%:20% split for training/testing. Images were reconstructed by MD-CNN and k-t Radial Sparse-Sense(kt-RASPS) using an undersampled dataset (14 of 196 acquired views; relative acceleration rate = 14). MD-CNN images were evaluated quantitatively using mean-squared-error (MSE) and structural similarity index (SSIM) relative to reference images, and qualitatively by three independent readers for left ventricular (LV) border sharpness and temporal fidelity using 5-point Likert-scale (1-non-diagnostic, 2-poor, 3-fair, 4-good, and 5-excellent). RESULTS: MD-CNN showed improved MSE and SSIM compared to kt-RASPS (0.11 ± 0.10 vs. 0.61 ± 0.51, and 0.87 ± 0.07 vs. 0.72 ± 0.07, respectively; P < .01). Qualitatively, MD-CCN significantly outperformed kt-RASPS in LV border sharpness (3.87 ± 0.66 vs. 2.71 ± 0.58 at end-diastole, and 3.57 ± 0.6 vs. 2.56 ± 0.6 at end-systole, respectively; P < .01) and temporal fidelity (3.27 ± 0.65 vs. 2.59 ± 0.59; P < .01). CONCLUSION: MD-CNN reduces the scan time of cine imaging by a factor of 23.3 and provides superior image quality compared to kt-RASPS.


Assuntos
Aprendizado Profundo , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Masculino , Redes Neurais de Computação , Estudos Retrospectivos
5.
Neuroradiology ; 63(2): 189-199, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32794074

RESUMO

PURPOSE: To investigate the clinical utility of pointwise encoding time reduction with radial acquisition in subtraction-based magnetic resonance angiography (PETRA-MRA) and time-of-flight magnetic resonance angiography (TOF-MRA) to evaluate saccular unruptured intracranial aneurysms (UIAs). METHODS: A total of 49 patients with 54 TOF-MRA-identified saccular UIAs were enrolled. The morphologic parameters, contrast-to-noise-ratios (CNRs), and sharpness of aneurysms were measured using PETRA-MRA and TOF-MRA. Two radiologists independently evaluated subjective image scores, focusing on aneurysm signal homogeneities and sharpness depictions using a 4-point scale: 4, excellent; 3, good; 2, poor; 1, not assessable. PETRA-MRA and TOF-MRA acoustic noises were measured. RESULTS: All aneurysms were detected with PETRA-MRA. The morphologic parameters of 15 patients evaluated with PETRA-MRA were more closely correlated with those receiving computed tomography angiography over those receiving TOF-MRA. No significant differences between PETRA-MRA and TOF-MRA parameters were seen in the 54 UIAs (p > 0.10), excluding those with inflow angles (p < 0.05). In four patients with inflow angles on PETRA-MRA, the angles were more closely related to those of digital subtraction angiography than those of TOF-MRA. CNRs between TOF-MRA and PETRA-MRA were comparable (p = 0.068), and PETRA-MRA sharpness values and subjective image scores were significantly higher than those of TOF-MRA (p < 0.001). Inter-observer agreements were excellent for both PETRA-MRA and TOF-MRA (intraclass correlation coefficients were 0.90 and 0.97, respectively). The acoustic noise levels of PETRA-MRA were much lower than those of TOF-MRA (59 vs.73 dB, p < 0.01). CONCLUSIONS: PETRA-MRA, with better visualization of aneurysms and lower acoustic noise levels than TOF-MRA, showed a superior diagnostic performance for depicting saccular UIAs.


Assuntos
Aneurisma Intracraniano , Angiografia por Ressonância Magnética , Angiografia Digital , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
6.
Acta Radiol ; 62(9): 1193-1199, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32867507

RESUMO

BACKGROUND: Although time-of-flight magnetic resonance angiography (TOF-MRA) is widely used, it has limited usefulness for follow-up after stent-assisted coil embolization. Contrast-enhanced MRA (CE-MRA) and ultrashort echo time MRA have been suggested as alternative methods for visualization after this procedure. PURPOSE: To compare efficacy and usefulness of pointwise encoding time reduction with radial acquisition (PETRA) sequence in subtraction-based MRA (qMRA), TOF-MRA, and CE-MRA during the follow-up after Neuroform Atlas stent-assisted coil embolization for intracranial aneurysms. MATERIAL AND METHODS: This retrospective study included 23 patients with 24 aneurysms who underwent Neuroform Atlas stent-assisted coil embolization for intracranial aneurysms. All patients were evaluated with PETRA qMRA, TOF-MRA, and CE-MRA at the same follow-up session. The flow within stents, occlusion status, and presence of pseudo-stenosis were evaluated; inter-observer and intermodality agreements for the three methods were also graded. RESULTS: The mean score for flow visualization within the stents was significantly higher for PETRA qMRA and CE-MRA than for TOF-MRA (although no significant difference was found between PETRA qMRA and CE-MRA). Good inter-observer agreement was observed for each modality. PETRA qMRA and CE-MRA were more consistent with digital subtraction angiography (DSA) than TOF-MRA for aneurysm occlusion status. The intermodality agreement was better between PETRA qMRA and DSA, and between CE-MRA and DSA, than between DSA and TOF-MRA. Pseudo-stenosis was most frequently observed in TOF-MRA, followed by CE-MRA and PETRA qMRA. CONCLUSION: PETRA qMRA is useful for evaluating the parent artery patency and occlusion status of aneurysms after Neuroform Atlas stent-assisted coil embolization.


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Angiografia por Ressonância Magnética/métodos , Stents , Adulto , Idoso , Meios de Contraste , Feminino , Seguimentos , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tempo , Resultado do Tratamento
7.
Neuroimage ; 188: 380-390, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30553917

RESUMO

The goal of this study was to develop a molecular biomarker for the detection of protein aggregation involved in Alzheimer's disease (AD) by exploiting the features of the water saturation transfer spectrum (Z-spectrum), the CEST signal of which is sensitive to the molecular configuration of proteins. A radial-sampling steady-state sequence based ultrashort echo time (UTE) readout was implemented to image the Z-spectrum in the mouse brain, especially the contributions from mobile proteins at the frequency offsets for the composite protein amide proton (+3.6 ppm) and aliphatic proton (-3.6 ppm) signals. Using a relatively weak radiofrequency (RF) saturation amplitude, contributions due to strong magnetization transfer contrast (MTC) from solid-like macromolecules and direct water saturation (DS) were minimized. For practical measure of the changes in the mobile protein configuration, we defined a saturation transfer difference (ΔST) by subtracting the Z-spectral signals at ±3.6 ppm from a control signal at 8 ppm. Phantom studies of glutamate solution, protein (egg white) and hair conditioner show the capability of the proposed scheme to minimize the contributions from amine protons, DS, and MTC, respectively. The ST signal at ±3.6 ppm of the cross-linked bovine serum albumin (BSA) solutions demonstrated that the ΔST signal can be used to monitor the aggregation process of the mobile proteins. High-resolution ΔST images of AD mouse brains at ±3.6 ppm of mouse brains showed significantly reduced ΔST (-3.6) signal compared to the age-matched wild-type (WT) mice. Thus, this signal has potential to serve as a molecular biomarker for monitoring protein aggregation in AD.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Agregados Proteicos , Animais , Biomarcadores , Modelos Animais de Doenças , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Transgênicos
8.
Pediatr Radiol ; 49(13): 1788-1797, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31485688

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) of the abdomen can be especially challenging in pediatric patients because of image quality degradation from respiratory motion. Abdominal MR protocols tailored for free-breathing children can potentially improve diagnostic image quality and reduce scan time. OBJECTIVE: To evaluate the performance of a free-breathing 3-T MRI protocol for renal evaluation in pediatric patients with tuberous sclerosis complex (TSC). MATERIALS AND METHODS: A single institution, Institutional Review Board-approved, retrospective database query identified pediatric TSC patients who underwent a free-breathing 3-T MR abdominal protocol including radial and respiratory-triggered pulse sequences and who also had a prior abdominal MRI on the same scanner using a traditional MR protocol utilizing signal averaging and Cartesian k-space sampling. Scan times and use of sedation were recorded. MR image quality was compared between the two protocols using a semiquantitative score for overall image quality and sharpness. RESULTS: Forty abdominal MRI studies in 20 patients were evaluated. The mean scan time of the fast free-breathing protocol was significantly lower (mean: 42.5±9.8 min) compared with the traditional protocol (58.7±11.7 min; P=<0.001). Image sharpness was significantly improved for radial T2-weighted and T1-weighted triggered Dixon and radial T1-weighted fat-suppressed post-contrast images in the free-breathing protocol, while image quality was significantly higher on radial and Dixon T1-weighted sequences. CONCLUSION: A free-breathing abdominal MR protocol in pediatric TSC patients decreases scan time and improves image quality and should be considered more widely for abdominal MRI in children.


Assuntos
Cavidade Abdominal/diagnóstico por imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Melhoria de Qualidade , Intensificação de Imagem Radiográfica , Esclerose Tuberosa/diagnóstico por imagem , Criança , Pré-Escolar , Estudos de Coortes , Meios de Contraste , Bases de Dados Factuais , Feminino , Humanos , Masculino , Respiração , Estudos Retrospectivos , Fatores de Tempo , Esclerose Tuberosa/fisiopatologia
9.
MAGMA ; 31(2): 235-242, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28770356

RESUMO

OBJECTIVES: Guidewires are indispensable tools for intravascular MR-guided interventions. Recently, an MR-safe guidewire made from a glass-fiber/epoxy compound material with embedded iron particles was developed. The size of the induced susceptibility artifact, and thus the guidewire's visibility, depends on its orientation against B 0. We present a radial acquisition scheme with variable echo times that aims to reduce the artifact's orientation dependency. MATERIALS AND METHODS: The radial acquisition scheme uses sine-squared modulated echo times depending on the physical direction of the spoke to balance the susceptibility artifact of the guidewire. The acquisition scheme was studied in simulations based on dipole fields and in phantom experiments for different orientations of the guidewire against B 0. The simulated and measured artifact widths were quantitatively compared. RESULTS: Compared to acquisitions with non-variable echo times, the proposed acquisition scheme shows a reduced angular variability. For the two main orientations (i.e., parallel and perpendicular to B 0), the ratio of the artifact widths was reduced from about 2.2 (perpendicular vs. parallel) to about 1.2 with the variable echo time approach. CONCLUSION: The reduction of the orientation dependency of the guidewire's artifact via sine-squared varying echo times could be verified in simulations and measurements. The more balanced artifact allows for a better overall visibility of the guidewire.


Assuntos
Artefatos , Procedimentos Endovasculares , Vidro , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Cateterismo , Simulação por Computador , Compostos de Epóxi , Desenho de Equipamento , Humanos , Imagens de Fantasmas
10.
Magn Reson Med ; 77(4): 1459-1472, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27052351

RESUMO

PURPOSE: Cardiac MR tagging techniques, which facilitate the strain evaluation, have not yet been widely adopted in clinics due to inefficiencies in acquisition and postprocessing. This problem may be alleviated by exploiting the coherency in the three steps of tagging: preparation, acquisition, and reconstruction. Herein, we propose a fully polar-based tagging approach that may lead to real-time strain mapping. METHODS: Radial readout trajectories were used to acquire radial tagging images and a Hankel-based algorithm, referred to as Polar Fourier Transform (PFT), has been adapted for reconstruction of the acquired raw data. In both phantom and human subjects, the overall performance of the method was investigated against radial undersampling and compared with the conventional reconstruction methods. RESULTS: Radially tagged images were reconstructed by the proposed PFT method from as few as 24 spokes with normalized root-mean-square-error of less than 3%. The reconstructed images showed a central focusing behavior, where the undersampling effects were pushed to the peripheral areas out of the central region of interest. Comparing the results with the re-gridding reconstruction technique, superior image quality and high robustness of the method were further established. In addition, a relative increase of 68 ± 2.5% in tagline sharpness was achieved for the PFT images and also higher tagging contrast (72 ± 5.6%), resulted from the well-tolerated undersampling artifacts, was observed in all reconstructions. CONCLUSION: The proposed approach led to the acceleration of the acquisition process, which was evaluated for up to eight-fold retrospectively from the fully sampled data. This is promising toward real-time imaging, and in contrast to iterative techniques, the method is consistent with online reconstruction. Magn Reson Med 77:1459-1472, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Técnicas de Imagem Cardíaca/métodos , Coração/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Técnicas de Imagem Cardíaca/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
J Magn Reson Imaging ; 45(3): 839-844, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27490158

RESUMO

PURPOSE: To assess airway visibility in infants using pointwise encoding time reduction with radial acquisition (PETRA). MATERIALS AND METHODS: PETRA was obtained in 37 infants (gestational age: 23-43 weeks; postconceptional age: 34-46 weeks) using 3T magnetic resonance imaging (MRI) without respiratory gating. The visibility of the branching point and the airway structures, including the trachea and bronchi, on PETRA was scored by two experienced pediatric radiologists using a four-point scale (0-3). The rates of good visibility (score 3 or 2) were calculated for each airway structure. Interrater agreement was evaluated by intraclass correlation coefficient (ICC). RESULTS: For readers 1 and 2, good visibility was achieved for the branching point of the main bronchi (76% and 95%, respectively), trachea (97% and 95%, respectively), right main bronchus (92% and 92%, respectively), and left main bronchus (97% and 84%, respectively). Lower rates of visibility were achieved for the lobar bronchi. There was substantial agreement (ICC: 0.61-0.79) between the two readers for all the airway structures, except for the branching point at the right upper/middle lobe bronchi, for which there was moderate agreement (ICC: 0.56). CONCLUSION: PETRA has the potential for good airway visibility in infants, particularly for the trachea and main bronchi. LEVEL OF EVIDENCE: 3 J. Magn. Reson. Imaging 2017;45:839-844.


Assuntos
Brônquios/anatomia & histologia , Brônquios/diagnóstico por imagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Traqueia/diagnóstico por imagem , Algoritmos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Traqueia/anatomia & histologia , Interface Usuário-Computador
12.
Magn Reson Med ; 76(3): 880-7, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26414857

RESUMO

PURPOSE: To reduce saturation effects in the arterial input function (AIF) estimation of quantitative myocardial first-pass saturation recovery perfusion imaging by employing a model-based reconstruction. THEORY AND METHODS: Imaging was performed with a saturation recovery prepared radial FLASH sequence. A model-based reconstruction was applied for reconstruction. By exploiting prior knowledge about the relaxation process, an image series with different saturation recovery times was reconstructed. By evaluating images with an effective saturation time of approximately 3 ms, saturation effects in the AIF determination were reduced. In a volunteer study, this approach was compared with a standard prebolus technique. RESULTS: In comparison to the low-dose injection of a prebolus acquisition, saturation effects were further reduced in the AIFs determined using the model-based approach. These effects, which were clearly visible for all six volunteers, were reflected in a statistically significant difference of up to 20% in the absolute perfusion values. CONCLUSION: The application of model-based reconstruction algorithms in quantitative myocardial perfusion imaging promises a significant improvement of the AIF determination. In addition to greatly reducing saturation effects that occur even for the prebolus methods, only a single bolus has to be applied. Magn Reson Med 76:880-887, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Meios de Contraste/farmacocinética , Circulação Coronária/fisiologia , Imageamento por Ressonância Magnética/métodos , Modelos Cardiovasculares , Imagem de Perfusão do Miocárdio/métodos , Miocárdio/metabolismo , Algoritmos , Simulação por Computador , Feminino , Coração , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Adulto Jovem
13.
Magn Reson Med ; 73(1): 284-91, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24435956

RESUMO

PURPOSE: To achieve whole-heart coronary magnetic resonance angiography (MRA) with (1.0 mm)(3) spatial resolution and 5 min of free-breathing scan time. METHODS: We used an electrocardiograph-gated, T2-prepared and fat-saturated balanced steady state free precession sequence with 3DPR trajectory for free-breathing data acquisition with 100% gating efficiency. For image reconstruction, we used a self-calibrating iterative SENSE scheme with integrated retrospective motion correction. We performed healthy volunteer study to compare the proposed method with motion-corrected gridding at different retrospective undersampling levels on apparent signal-to-noise ratio (aSNR) and subjective coronary artery (CA) visualization scores. RESULTS: Compared with gridding, the proposed method significantly improved both image quality metrics for undersampled datasets with 6000, 8000, and 10,000 projections. With as few as 10,000 projections, the proposed method yielded good CA visualization scores (3.02 of 4) and aSNR values comparable to those with 20,000 projections. CONCLUSION: Using the proposed method, good image quality was observed for free breathing whole-heart coronary MRA at (1.0 mm)(3) resolution with an achievable scan time of 5 min.


Assuntos
Artefatos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Vasos Coronários/anatomia & histologia , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Algoritmos , Angiografia Coronária/métodos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Movimento (Física) , Movimento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Magn Reson Med ; 73(1): 292-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24478142

RESUMO

PURPOSE: To compare the applicability of different self-gating (SG) strategies for respiratory SG in cardiac MRI in combination with iteratively reconstructed (k-t SPARSE SENSE) cine data with low and high temporal resolution. METHODS: Eleven SG variants were compared in five volunteers by assessment of the resulting image sharpness compared with nongated reconstructions. Promising SG techniques were applied for high temporal resolution reconstructions of the heart function. RESULTS: SG was successful in all volunteers with image-based SG and the ∑||p|| technique. These approaches were also superior to gating from the respiratory bellows signal on average. Combination with k-t SPARSE SENSE enabled high temporally resolved visualization of the heart motion with free breathing. CONCLUSION: Respiratory SG can be applied for improving image sharpness. Combining SG with iterative reconstruction allows generation of high temporal resolution cine data, which reveal more details of cardiac motion.


Assuntos
Coração/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Adulto , Algoritmos , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
15.
J Magn Reson Imaging ; 41(2): 447-53, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24578275

RESUMO

PURPOSE: To compare the lesion contrast and signal to noise ratio (SNR) obtained with T1-weighted pointwise encoding time reduction with radial acquisition (PETRA) to those of Magnetization-Prepared RApid Gradient-Echo (MPRAGE) for contrast-enhanced imaging of primary and metastatic intracranial tumors, and to investigate whether PETRA is able to reduce acoustic noise for improved patient comfort. MATERIALS AND METHODS: Fifteen patients with intracranial tumors underwent 3 Tesla MRI including inversion-prepared PETRA and MPRAGE. The two sequences had comparable scan times, spatial resolution and spatial coverage. "Tumor conspicuity" was rated qualitatively by two radiologists, while enhancing lesion-to-white matter contrast to noise ratio (CNR) and white-matter SNR were analyzed quantitatively using paired t-tests. The acoustic noise generated by each sequence was measured. RESULTS: Qualitative rating of "tumor conspicuity" by two radiologists resulted in nearly identical average scores for the two sequences. Quantitative analyses revealed that (i) there was no significant difference between the mean CNR values of the two sequences (P = 0.57), (ii) the mean SNR of PETRA was significantly higher than that of MPRAGE (P < 0.01), and (iii) the mean sound level of PETRA was significantly lower than that of MPRAGE (P < 0.01). CONCLUSION: Inversion-prepared PETRA was found to be viable as a quiet alternative to MPRAGE for contrast-enhanced T1-weighted studies of intracranial tumors.


Assuntos
Neoplasias Encefálicas/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído
16.
Magn Reson Med ; 72(3): 749-55, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24122950

RESUMO

PURPOSE: To improve quantification of myocardial blood flow using a fast T1 mapping technique using highly constrained back projection reconstruction (HYPR)-accelerated acquisition. METHODS: A major source of error in the measurement of myocardial blood flow (MBF) using MRI is the nonlinear relationship between image signal intensity and contrast agent (CA) concentration. HYPR-accelerated radial acquisition was used to generate pixel-wise T1 maps with a temporal resolution of one heartbeat. HYPR produces images with a temporal footprint of 40 ms and four images within 188 ms. T1 values were converted into CA concentrations by the known linear relationship between CA concentration and T1 . The T1 mapping technique was used to quantify MBF in 10 healthy subjects and compared with MBF found using image signal intensity as well as MBF reported in the literature. RESULTS: The MBF measured using the proposed method was more consistent with that previously reported in the literature and was significantly lower (P = 0.002) than that calculated using image signal intensity (1.11 ± 0.27 mL/min/g versus 1.88 ± 0.45 mL/min/g, respectively). CONCLUSION: We developed a fast T1 mapping method for MBF quantification using radial sampling and HYPR. Further validation is required to determine its clinical value in assessing myocardial perfusion deficit in coronary artery disease.


Assuntos
Coração/anatomia & histologia , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Cardíaca , Simulação por Computador , Meios de Contraste/administração & dosagem , Feminino , Humanos , Masculino , Compostos Organometálicos/administração & dosagem , Imagens de Fantasmas , Fatores de Tempo
17.
Magn Reson Med ; 71(1): 67-74, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23401157

RESUMO

PURPOSE: To develop a three-dimensional retrospective image-based motion correction technique for whole-heart coronary MRA with self-navigation that eliminates both the need to setup a diaphragm navigator and gate the acquisition. METHODS: The proposed technique uses one-dimensional self-navigation to track the superior-inferior translation of the heart, with which the acquired three-dimensional radial k-space data is segmented into different respiratory bins. Respiratory motion is then estimated in image space using an affine transform model and subsequently this information is used to perform efficient motion correction in k-space. The performance of the proposed technique on healthy volunteers is compared with the conventional navigator gating approach as well as data binning using diaphragm navigator. RESULTS: The proposed method is able to reduce the imaging time to 7.1±0.5 min from 13.9±2.6 min with conventional navigator gating. The scan setup time is reduced as well due to the elimination of the navigator. The proposed method yields excellent image quality comparable with either conventional navigator gating or the navigator binning approach. CONCLUSION: We have developed a new respiratory motion correction technique for coronary MRA that enables 1 mm(3) isotropic resolution and whole-heart coverage with 7 min of scan time. Further tests on patient population are needed to determine its clinical usage.


Assuntos
Algoritmos , Artefatos , Angiografia Coronária/métodos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Adulto , Vasos Coronários/anatomia & histologia , Humanos , Masculino , Movimento (Física) , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
18.
Magn Reson Med ; 72(5): 1208-17, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25216287

RESUMO

PURPOSE: To develop a cardiac and respiratory self-gated four-dimensional (4D) coronary MRA technique for simultaneous cardiac anatomy and function visualization. METHODS: A contrast-enhanced, ungated spoiled gradient echo sequence with self-gating (SG) and 3DPR trajectory was used for image acquisition. Data were retrospectively binned into different cardiac and respiratory phases based on information extracted from SG projections using principal component analysis. Each cardiac phase was reconstructed using a respiratory motion-corrected self-calibrating SENSE framework, and those belong to the quiescent period were retrospectively combined for coronary visualization. Healthy volunteer studies were conducted to evaluate the efficacy of the SG method, the accuracy of the left ventricle (LV) function parameters and the quality of coronary artery visualization. RESULTS: SG performed reliably for all subjects including one with poor electrocardiogram (ECG). The LV function parameters showed excellent agreement with those from a conventional cine protocol. For coronary imaging, the proposed method yielded comparable apparent signal to noise ratio and coronary sharpness and lower apparent contrast to noise ratio on three subjects compared with an ECG and navigator-gated Cartesian protocol and an ECG-gated, respiratory motion-corrected 3DPR protocol. CONCLUSION: A fully self-gated 4D whole-heart imaging technique was developed, potentially allowing cardiac anatomy and function assessment from a single measurement.


Assuntos
Vasos Coronários/anatomia & histologia , Eletrocardiografia , Angiografia por Ressonância Magnética/métodos , Adulto , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Análise de Componente Principal , Técnicas de Imagem de Sincronização Respiratória , Estudos Retrospectivos
19.
J Magn Reson Imaging ; 40(2): 413-22, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24895008

RESUMO

PURPOSE: To demonstrate radial golden-ratio-based cardiac cine imaging by using interspersed one-dimensional (1D) navigators. MATERIALS AND METHODS: The 1D navigators were interspersed into the acquisition of radial spokes which were continuously rotated by an angle increment based on the golden-ratio. Performing correlation analysis between the 1D navigator projections, time points corresponding to the same cardiac motion phases were automatically identified and used to combine retrospectively golden-ratio rotated radial spokes from multiple data windows. Data windows were shifted consecutively for dynamic reconstruction of different cardiac motion frames. Experiments were performed during a single breathhold. By artificially reducing the amount of input data, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as artifact level was evaluated for different breathhold durations. RESULTS: Analysis of the 1D navigator data provided a detailed correlation function revealing cardiac motion over time. Imaging results were comparable to images reconstructed based on a timely synchronized ECG. Cardiac cine images with a low artifact level and good image quality in terms of SNR and CNR were reconstructed from volunteer data achieving a CNR between the myocardium and the left ventricular cavity of 50 for the longest breathhold duration of 26 s. CNR maintained a value higher than 30 for acquisition times as low as 10 s. CONCLUSION: Combining radial golden-ratio-based imaging with an intrinsic navigator is a promising and robust method for performing high quality cardiac cine imaging.


Assuntos
Algoritmos , Coração/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Técnica de Subtração , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
20.
J Magn Reson Imaging ; 39(1): 179-88, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23857797

RESUMO

PURPOSE: To improve compressed sensing (CS) reconstruction of accelerated breath-hold (BH) radial cine magnetic resonance imaging (MRI) by exploiting auxiliary data acquired between different BHs. MATERIALS AND METHODS: Cardiac function is usually assessed using segmented cine acquisitions over multiple BHs to cover the entire left ventricle (LV). Subjects are given a resting period between adjacent BHs, when conventionally no data are acquired and subjects rest in the scanner. In this study the resting periods between BHs were used to acquire additional free-breathing (FB) data, which are subsequently used to generate a sparsity constraint for each cardiac phase. Images reconstructed using the proposed sparsity constraint were compared with conventional CS using a composite image generated by averaging different cardiac phases. The efficacy of the proposed reconstruction was compared using indices of LV function and blood-myocardium sharpness. RESULTS: The proposed method provided accurate LV ejection fraction measurements for 33% and 20% sampled datasets compared with fully sampled reference images, and showed 14% and 11% higher blood-myocardium border sharpness scores compared to the conventional CS. CONCLUSION: The FB data acquired during resting periods can be efficiently used to improve the image quality of the undersampled BH data without increasing the total scan time.


Assuntos
Coração/fisiologia , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Respiração , Algoritmos , Suspensão da Respiração , Circulação Coronária , Eletrocardiografia/métodos , Voluntários Saudáveis , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa