Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Odontology ; 109(2): 433-439, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33128650

RESUMO

This study aims to compare the degree of conversion of two different curing protocols used during adhesive cementation. The following resin luting agents were tested: Hri Flow (MF) and pre-heated Hri Micerium (MH); light-cure Nexus Third Generation (NX3L) and dual-cure Nexus Third Generation (NX3D); dual cured RelyX Ultimate (RXU) and light-cure RelyX Veneers (RXL). For each tested material, ten samples were prepared and divided into two groups which had different curing protocols (P1 and P2): in P1, samples were cured for 40 s; in P2, samples were cured for 5 s, and then, after 20 s, cured again for additional 40 s. The degree of conversion (DC) was evaluated both during the first 5 min of the curing phase and after 1, 2, 7, 14 and 28 days (p = 0.05). Different trends were observed in DC values after 5 min by comparing P1 and P2. In both P1 and P2, DC decreased as follows, MH > MF > NX3L > RXL > RXU > NX3D. There were significant differences of DC values among all resin luting agents (p < 0.05) in P1, while no significant differences existed between MH and MF, and NX3L and RXL in P2. At 1, 2, 7, 14 and 28 days the light curing luting agents had a higher DC than the dual luting agents (p < 0.05). P1 and P2 were not statistically different at each time point (p > 0.05). Both P1 and P2 protocols let achieve an acceptable DC after 28 days. The tested P2 can be safely used to lute indirect restorations, simplifying the removal of cement excesses.


Assuntos
Cimentação , Cimentos Dentários , Materiais Dentários , Teste de Materiais , Cimentos de Resina
2.
Gen Dent ; 68(4): 44-48, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32597777

RESUMO

This study aimed to evaluate the effect of different LED irradiance levels on the degree of conversion (DC) of dual-cured resin luting agents photocured through a high-translucency zirconia disc. Fifty-four disc specimens (approximately 0.1 × 6.0 × 6.0 mm) were prepared using 3 dual-cured resin luting agents (Panavia F 2.0, RelyX Unicem 2 Automix, and Calibra). Eighteen groups (n = 3) were evaluated. Test specimens were photocured through a 0.7 × 10.0-mm, high-translucency zirconia disc for 20 seconds using 1 of 3 different LED irradiances (mean output of 855, 1330, or 1750 mW/cm2 after 3 consecutive measurements with an LED radiometer). Specimens photocured directly, without a zirconia disc, were used as controls. Microattenuated total reflectance/Fourier-transform infrared spectroscopy was used to evaluate the extent of polymerization of all specimens prior to curing (baseline) and 24 hours after curing. Data were analyzed by 3-way analysis of variance and Tukey multiple comparisons test (α = 0.05). The RelyX Unicem 2 Automix and Panavia F 2.0 specimens showed no statistically significant difference in the mean DC after the use of different LED irradiance levels (P = 0.15 and P = 0.91, respectively) or when photocured with or without the use of a zirconia disc (P = 0.56 and P = 0.86, respectively). The Calibra specimens cured at the lowest irradiance level (855 mW/cm2) presented a significantly lower mean DC (P = 0.001). However, there was no statistically significant difference in the mean DC values when Calibra was photocured directly or through a zirconia disc (P = 0.33). The interpositioning of a high-translucency zirconia material did not reduce the DC of the tested resin luting agents compared to directly irradiated resin luting agents. The influence of different LED irradiance levels on the DC of dual-cured resin luting agents was material dependent.


Assuntos
Cimentos de Resina , Zircônio , Teste de Materiais
3.
J Dent ; 147: 105147, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38909647

RESUMO

PURPOSE: The aim of the study was (a) to assess the effect of universal adhesives and tooth primers with novel touch-cure activators on the conversion of dual-cured resin composite luting agents (RLAs) polymerized under the self-curing mode, and (b) to investigate the source of the catalytic effect exerted by the activators. MATERIALS AND METHODS: The materials selected were the adhesive RLAs Panavia V5/Tooth Primer (PV5/TP5), Variolink Esthetic DC/Adhese Universal DC (VLE/ADC), and the self-adhesive RLAs GCem ONE/AE Primer (GCO/AEP), RelyX Universal/Scotchbond Universal Plus (RXU/SUP) and Panavia SA Universal/Clearfil Universal Bond Quick (PSU/CUQ), the later serving as a control with an aryl-sulfinate activator. Coronal dentin specimens were prepared (n = 5/material), treated with the corresponding primers/adhesives (non-irradiated) and covered with a 100 µm-thick RLA layer (SC+A group). Three specimen series were additionally prepared (n = 3 × 5/material): A self-cured without the primers/adhesives (SC group), a dual-cured (20 s irradiation) with the corresponding primers/adhesives (DC+A group) and a dual-cured without primers/adhesives (DC group). All specimens were stored for 15 min (37 °C/dark/60 %RH). After demolding the degree of C = C conversion (DC%, top RLA surfaces) was measured by ATR-FTIR spectroscopy. The primer/adhesive liquids were further analyzed by ICP-MS and the microbrush tips of ADC by SEM-EDS. RESULTS: The touch-cure activators increased the DC% in all self-cured RLAs but failed to reach the values of the corresponding dual-cured RLAs. The effect of the activators in dual-cured specimens was negligible. The ICP-MS analysis showed the presence of V (AEP, TP5, ADC) and Cu (SUP) transitional metals in the activators, with V been located at the free ends of ADC tip bristles. The V activators demonstrated the highest DC% improvement in self-cured specimens. CONCLUSION: The new touch-cure activators significantly increased the conversion of the self-cured RLAs. Therefore, this step should be considered as universally applicable and not selective, as currently proposed for the self-adhesive luting agents by the manufacturers.


Assuntos
Resinas Compostas , Teste de Materiais , Polimerização , Cimentos de Resina , Resinas Compostas/química , Humanos , Cimentos de Resina/química , Metacrilatos/química , Dentina , Autocura de Resinas Dentárias/métodos , Espectroscopia de Infravermelho com Transformada de Fourier , Cimentos Dentários/química , Adesivos Dentinários/química , Propriedades de Superfície
4.
Dent Mater J ; 41(6): 833-842, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-35934801

RESUMO

This study aimed to comprehensively evaluate the effect of dual-cured resin luting agents with different initiator systems on the color stability of glass ceramic restorations by simulating various clinical glass ceramic restorations. Three commonly used shades from each of the two dual-cured resin luting agents with an amine-initiation system or without it were studied. The individual specimens had different translucency and thickness and were artificially aged using a xenon light aging machine. The color was measured before and after aging using a digital spectrophotometer with the difference calculated and analyzed statistically. As results, the amine-free dual-cured resin luting agents were more color stable than those using amine-initiation systems for both uncovered and bonding groups. The translucency and thickness of the ceramic, and shade and type of the resin luting agent significantly affected the color stability of glass ceramic restorations.


Assuntos
Porcelana Dentária , Cimentos de Resina , Cerâmica , Cor , Teste de Materiais
5.
Braz. dent. j ; 35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - odontologia (Brasil) | ID: biblio-1550094

RESUMO

Abstract This study investigated microshear bond strength (µSBS) of two (2) dual-cured resin-luting agents (RelyX™ Ultimate and RelyX™ U200) when photoactivated through varying thicknesses of lithium disilicate, with or without thermal cycling. Discs of IPS e.max Press of 0.5, 1.5, and 2 mm in thickness were obtained. Elastomer molds (3.0 mm in thickness) with four cylinder-shaped orifices 1.0 mm in diameter, were placed onto the ceramic surfaces and filled with resin-luting agents. A Mylar strip, glass plate, and load of 250 grams were placed over the filled mold. The load was removed and the resin-luting agents were photoactivated through the ceramics using a single-peak LED (Radii Plus.) All samples were stored in distilled water at 37oC for 24 h. Half of the samples were subjected to thermal cycling (3,000 cycles; 5ºC and 55ºC). All samples were then submitted to µSBS test using a universal testing machine (Instron 4411) at a crosshead speed of 0.5 mm/min. Data were submitted to three-way ANOVA and Tukey post-hoc test (α=0.05). The mean µSBS at 24 h was significantly higher than after thermal cycling (p<0.05). No statistical difference was found between resin-luting agents (p > 0.05). The mean µSBS for groups photoactivated through 0.5 mm ceramic were significantly higher than 1.5 mm and 2.0 mm (p < 0.05). In conclusion, increased ceramic thicknesses reduced the bond strength of tested resin-luting agents to lithium disilicate. No differences were found between resin-luting agents. Thermal cycling reduced the bond strength of both resin-luting agents.


Resumo: Este estudo investigou a resistência de união ao microcisalhamento (RUµC) de dois (2) agentes de cimentação de resina dual (RelyX™ Ultimate e RelyX™ U200) quando fotoativados através de diferentes espessuras de dissilicato de lítio, com ou sem ciclagem térmica. Discos do IPS e.max Press de 0,5, 1,5 e 2 mm de espessura foram obtidos. Moldes de elastômero (3,0 mm de espessura) com quatro orifícios cilíndricos de 1,0 mm de diâmetro foram colocados sobre as superfícies cerâmicas e preenchidos com agentes de cimentação de resina. Uma tira Mylar, placa de vidro e carga de 250 gramas foram colocadas sobre o molde preenchido. A carga foi removida e os agentes de cimentação resinosos foram fotoativados através da cerâmica usando um LED de pico-único (Radii Plus). Todas as amostras foram armazenadas em água deionizada a 37oC por 24 h. Metade das amostras foi submetida a ciclagem térmica (3.000 ciclos; 5ºC e 55ºC). Todas as amostras foram então submetidas ao teste de RUµC usando uma máquina de teste universal (Instron 4411) com velocidade de 0,5 mm/min. Os dados foram submetidos à Análise de Variância três fatores e ao teste post-hoc de Tukey (α = 0,05). A média de RUµC em 24 h foi significativamente maior do que após a ciclagem térmica (p < 0,05). Não houve diferença estatística entre os cimentos resinosos (p > 0,05). As médias de RUµC para grupos fotoativados através de cerâmica de 0,5 mm foram significativamente maiores do que 1,5 mm e 2,0 mm (p < 0,05). Em conclusão, o aumento da espessura da cerâmica reduziu a resistência de união dos agentes de cimentação resinosos ao dissilicato de lítio. Não foram encontradas diferenças entre os agentes de cimentação resinosos. A ciclagem térmica reduziu a resistência de união de ambos os agentes de cimentação resinosos.

6.
Dent Mater ; 33(3): 344-357, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28174008

RESUMO

OBJECTIVE: To evaluate the degree of conversion (DC%), salt yield and mechanical properties of self-adhesive luting agents (SAA) set under dual-cure (E) and self-cure (NE) modes. METHODS: Three SAA (GC LinkAce/GCLA, MaxCem Elite/MXEL, Rely-X Unicem 2/RXUN) and an adhesive resin luting agent (Rely-X Ultimate/RXUL-control) were used. The properties tested under E and NE modes were a) DC% and phosphate salt yield after 10min, 1h (h) and 3 weeks (w) storage, by infrared spectroscopy; and b) the mechanical properties of 3w-stored specimens by instrumented indentation testing (Martens hardness/HM, Elastic modulus/EIT, Elastic index/ηIT) and microscopic Vickers hardness/VH. Statistical analysis was performed by 3-way ANOVA (DC%), 2-way ANOVA (salt yield) and 1-way ANOVA (mechanical properties) at an a=0.05. RESULTS: Significantly higher DC% was found in E, except from the 3w groups of GCLA and MXEL. Within E, no significant differences were found, but within NE, there were differences in the 3 w groups of GCLA (vs 10 min) and MXEL (vs 1h). All materials demonstrated increased salt yield in NE, with the highest values found in RXUL and RXUN. GCLA, RXUL showed the lowest HM in E and MXEL the highest in NE. The rankings of the significant differences in EIT were MXEL>GCLA,RXUN,RXUL (E) and RXUL,MXEL>GCLA,RXUN (NE), whereas for ηIT RXUL,RXUN>GCLA,MXEL (E) and GCLA>RXUL>MXEL,RXUN (NE). The results of VH measurements showed an overestimation ranging from 13% up to 38% in comparison with HM. SIGNIFICANCE: There are significant differences in the properties tested, which may anticipate variations in the chemical, mechanical and biological performance of the products.


Assuntos
Cimentos Dentários , Cimentos de Resina , Dureza , Teste de Materiais , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa