Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 196
Filtrar
1.
Braz. dent. sci ; 27(2): 1-10, 2024. ilus, tab
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1563105

RESUMO

Objective: To evaluate the effect of saliva contamination and different decontamination protocols on the microshear bond strength of a universal adhesive to dentin. Material and Methods: 84 bovine teeth were divided into three groups according to bonding stage at which salivary contamination occurred; before curing of the adhesive, after curing of the adhesive, and a control group with no salivary contamination. Each group was further subdivided into four subgroups according to the decontamination protocol used (n=7): no decontamination protocol, rinsing then reapplication of the adhesive, grinding with sandpaper silicon carbide grit 600 then reapplication of the adhesive and finally ethanol application then reapplication of the adhesive. Specimens were tested in micro-shear mode. Results: All the decontamination protocols used in this study to reverse effect of salivary contamination before curing significantly improved the bond strength to contaminated dentin (p<0.001). Meanwhile, after curing, ethanol decontamination protocol recorded highest bond strength followed by rinsing and grinding compared to no decontamination (p<0.001). Conclusion: Saliva contamination led to significant deterioration in the bond strength regardless of the bonding stage at which saliva contamination occurred. All decontamination protocols improved the immediate microshear bond strength when contamination occurred before curing of the adhesive, while ethanol seemed to be the most effective both before curing and after curing (AU)


Objetivo: Avaliar o efeito da contaminação por saliva e de diferentes protocolos de descontaminação na resistência de união ao microcisalhamento de um adesivo universal à dentina. Material e Métodos: 84 dentes bovinos foram divididos em três grupos de acordo com o passo operatório do protocolo adesivo em que ocorreu a contaminação por saliva: antes da polimerização do adesivo, ou após a polimerização do adesivo e um grupo controle sem contaminação por saliva. Cada grupo foi subdividido em quatro subgrupos de acordo com o protocolo de descontaminação utilizado (n=7): sem protocolo de descontaminação; lavagem seguida da reaplicação do adesivo; lixar a região com lixa de carbeto de silício de granulação 600 e reaplicar o adesivo; aplicar etanol e reaplicar o adesivo. Os espécimes foram testados no modo de micro-cisalhamento. Resultados: Todos os protocolos de descontaminação utilizados neste estudo em busca de reverter o efeito da contaminação do adesivo por saliva melhoraram significativamente a resistência de união à dentina contaminada (p<0,001). Enquanto isso, após a polimerização, o protocolo de descontaminação com etanol resultou na maior resistência de união, seguido pela lavagem, e depois pelo lixamento, em comparação com nenhum protocolo de descontaminação (p<0,001). Conclusão: A contaminação por saliva levou a uma deterioração significativa na resistência de união, independentemente do passo operatório do protocolo adesivo em que ocorreu a contaminação por saliva. Todos os protocolos de descontaminação melhoraram a resistência de união ao microcisalhamento imediato quando a contaminação ocorreu antes da polimerização do adesivo, enquanto o etanol pareceu ser o protocolo mais eficaz nos dois tipos de contaminação (antes e depois da polimerização).


Assuntos
Saliva , Descontaminação , Adesivos Dentinários , Resistência ao Cisalhamento , Etanol
2.
Braz. dent. sci ; 26(4): 1-10, 2023. ilus, tab
Artigo em Inglês | BBO - odontologia (Brasil), LILACS | ID: biblio-1516476

RESUMO

Objective: to evaluate the effect of material type and veneer thickness on the final color and shear bond strength of PEEK bilayered restorations. Material and Methods: sixty-four square-shaped core specimens (7×7×2), were fabricated by CAD/CAM technology from two high-strength polymers, BioHPP (High-Performance Polymer, group B n=32), and Pekkton® ivory (PolyEtherKetoneKetone, group P n=32) then were veneered with resin composite (crea.lign dentin A3). Specimens from each group were divided (n=16) according to the veneer layer thickness (0.5 & 1 mm), then according to the test applied (n=8), either ΔE or shear bond strength (SBS). Specimen surfaces were treated according to the manufacturer's instructions. Specimens were veneered according to the manufacturer's instructions.The mode of failure was evaluated under a stereomicroscope at 40 x magnification after the shear bond strength test. Results: data showed parametric distribution and variance homogeneity and were analyzed using two-way ANOVA. The significance level was set at p<0.05 for all tests. Statistical analysis was performed with the R statistical analysis software version 4.3.1.Results of two-way ANOVA showed that material types and veneer thicknesses had an individual significant effect on the color change. For the shear bond strength, only the sample thickness (1mm) had a significant effect (p=0.033). The majority of samples in different groups presented a mixed failure mode with all the differences being not statistically significant (p>0.05). Conclusion: the thickness of the resin composite veneer can significantly affect the final esthetic outcome and shear bond strength of a bilayered restoration.(AU)


Objetivo: avaliar o efeito do tipo de material e da espessura do revestimento na cor final e na resistência ao cisalhamento de restaurações em duas camadas de PEEK. Material e Métodos: foram fabricados 64 espécimes com núcleo de formato quadrado (7x7x2) usando tecnologia CAD/CAM a partir de dois polímeros de alta resistência, BioHPP (Polímero de Alto Desempenho, grupo B n=32) e Pekkton ivory (Polieterecetona cetona, grupo P n=32), que foram então revestidos com resina composta (crea.lign dentin A3). Os espécimes de cada grupo foram divididos (n=16) de acordo com a espessura do revestimento (0,5 e 1 mm), e depois de acordo com o teste aplicado (n=8), seja ΔE ou resistência ao cisalhamento (SBS). As superfícies dos espécimes foram tratadas de acordo com as instruções do fabricante. Os espécimes foram revestidos de acordo com as instruções do fabricante. O modo de falha foi avaliado sob um estereomicroscópio com ampliação de 40x após o teste de resistência ao cisalhamento. Resultados: os dados apresentaram distribuição paramétrica e homogeneidade de variância e foram analisados por ANOVA de duas vias. O nível de significância foi estabelecido em p<0,05 para todos os testes. A análise estatística foi realizada com o software de análise estatística R, versão 4.3.1. Os resultados da ANOVA de duas vias mostraram que os tipos de materiais e as espessuras do revestimento tiveram um efeito significativo individual na mudança de cor. Para a resistência ao cisalhamento, apenas a espessura da amostra (1mm) teve um efeito significativo (p=0,033). A maioria das amostras em diferentes grupos apresentou um modo de falha misto, com todas as diferenças não sendo estatisticamente significativas (p>0,05). Conclusão:a espessura do revestimento de resina composta pode afetar significativamente o resultado estético final e a resistência ao cisalhamento de uma restauração em duas camadas.(AU)


Assuntos
Polímeros , Resinas Compostas , Resistência ao Cisalhamento
3.
Braz. dent. sci ; 26(3): 1-13, 2023. tab, ilus
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1437871

RESUMO

Objective: to evaluate the effect of novel zirconia surface treatment method on shear bond strength between zirconia and veneering porcelain compared to air abrasion and CoJet surface treatment methods. Material and Methods: twenty-one zirconia ceramic discs were fabricated with diameter of 7mm and 3mm thickness and divided according to surface treatment into three subgroups, control group I: Air Abrasion (n=7), group II: CoJet (n=7) and group III: Z-etch (n=7). Porcelain was built over the zirconia specimens with a customized mold and fired in a ceramic furnace. All specimens were thermocycled (20000 cycles) between 5°C ­ 55 °C with a dwell time of 30 seconds in distilled water and shear bond strength of veneering porcelain to each zirconia specimen was tested using a universal testing machine. Results: numerical data were explored for normality by checking the distribution of data and using tests of normality (Kolmogorov-Smirnov and Shapiro-Wilk tests). One-way ANOVA test was used to compare between the groups. There was a statistically significant difference between the three groups (P-value = 0.002, Effect size = 0.503). Pair-wise comparisons between groups revealed that Z-etch showed the statistically significantly highest mean shear bond strength. Conclusion: zirconia coating using z-etch is showing promising results in promoting higher bond strength than conventional surface treatment methods as air abrasion and silica coating (AU)


Objetivo: avaliar o efeito do novo método de tratamento de superfície de zircônia na resistência ao cisalhamento entre a zircônia e a porcelana de cobertura em comparação com os métodos de abrasão a ar e jateamento com CoJet. Material e Métodos: vinte e um discos de zircônia foram confeccionados com diâmetro de 7mm e espessura de 3mm e divididos de acordo com o tratamento de superfície em três subgrupos, grupo controle I: Abrasão a ar (n=7), grupo II: CoJet (n=7) e grupo III: Z-etch (n=7). A porcelana foi aplicada sobre os espécimes de zircônia com um molde personalizado e sinterizada em forno de cerâmica. Todos os espécimes foram termociclados (20.000 ciclos) entre 5°C - 55°C com um tempo de permanência de 30 segundos em água destilada e a resistência ao cisalhamento da porcelana de cobertura foi testada através de uma máquina de ensaio universal. Resultados: os dados numéricos foram avaliados quanto à normalidade, verificando a distribuição dos dados e utilizando testes de normalidade (testes de Kolmogorov-Smirnov e Shapiro-Wilk). O teste ANOVA de um fator foi utilizado para comparar os grupos. Houve uma diferença estatisticamente significativa entre os três grupos (P-valor = 0,002, tamanho do efeito = 0,503). As comparações pareadas entre os grupos revelaram que o Z-etch apresentou a resistência de união ao cisalhamento estatisticamente significativamente mais alta. Conclusão: o revestimento de zircônia utilizando Z-etch mostrou resultados promissores para o aumento da resistência de união em comparação aos métodos convencionais de tratamento de superfície, como abrasão a ar e revestimento de sílica (AU)


Assuntos
Abrasão Dental por Ar , Resistência ao Cisalhamento , Materiais Dentários
4.
Rev. Cient. CRO-RJ (Online) ; 7(3): 52-57, Sept. - Dec. 2022.
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1437880

RESUMO

Objective: this in vitro study compared the adhesive strengths of the resin sealant with the Giomer technology sealant under salivary contamination. Materials and Methods: fifty-two bovine incisors were randomly divided into four groups (n=13): GI, a resin sealant (Fluroshield®) without salivary contamination (control of GII); GII, Fluroshield sealant + salivary contamination; GIII, a Giomer technology sealant (BeautiSealant®) without salivary contamination (control of GIV); and GIV, BeautiSealant® sealant + salivary contamination. In the salivary contamination groups, artificial saliva was used through a pipette, and after 20 s, it was air-dried and the sealant was applied. Shear strength tests were performed using a universal testing machine. One-way ANOVA variance and Tukey's test were used for multiple comparisons. The fracture types were analyzed using a stereomicroscope with 40X magnification. Results: the means and standard deviations (SD) of adhesion for Fluroshield® and BeautiSealant® in the group without salivary contamination were 15.27 (±0.96) and 11.90 (±0.94), and for the group with salivary contamination, 13.14 (±1.03) and 8.95 (±1.33), respectively, indicating a statistically significant difference between GI and GII p=0.020, GIII and GIV p=0.041. Mixed failures were detected in GI (38%), GII (44%), GIII (38%), and GIV (62%). Conclusion: there was a statistically significant decrease in the adhesive strength values in the groups with salivary contamination for both the sealants studied. However, no significant difference was observed between the two sealants when the materials used were compared.


Objetivo: este estudo in vitro comparou as forças adesivas do selante resinoso com o selante da tecnologia Giomer sob contaminação salivar. Materiais e Métodos: cinquenta e dois incisivos bovinos foram divididos aleatoriamente em quatro grupos (n=13): GI, um selante resinoso (Fluroshield®) sem contaminação salivar (controle do GII); GII, selante Fluroshield + contaminação salivar; GIII, um selante com tecnologia Giomer (BeautiSealant®) sem contaminação salivar (controle do GIV); e GIV, selante BeautiSealant® + contaminação salivar. Nos grupos de contaminação salivar, a saliva artificial foi utilizada por meio de uma pipeta e, após 20 s, foi seca ao ar e aplicado o selante. Os testes de resistência ao cisalhamento foram realizados usando uma máquina de teste universal. A variância ANOVA de uma via e o teste de Tukey foram usados para comparações múltiplas. Os tipos de fratura foram analisados em estereomicroscópio com aumento de 40X. Resultados: as médias e desvios padrão (DP) de adesão para Fluroshield® e BeautiSealant® no grupo sem contaminação salivar foram 15,27 (±0,96) e 11,90 (±0,94), e após contaminação salivar foram 13,14 (±1,03) e 8,95 (±1,33), respectivamente, indicando haver diferença estatisticamente significante entre GI e GII p=0.020, GIII e GIV p=0.041. Falhas mistas foram detectadas em GI (38%), GII (44%), GIII (38%) e GIV (62%). Conclusão: houve diminuição estatisticamente significativa dos valores de resistência adesiva nos grupos com contaminação salivar para ambos os selantes estudados. No entanto, não foi observada diferença significativa entre os dois selantes quando comparados os materiais utilizados.


Assuntos
Selantes de Fossas e Fissuras , Saliva Artificial , Resistência ao Cisalhamento
5.
Dental press j. orthod. (Impr.) ; 27(4): e2220365, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - odontologia (Brasil) | ID: biblio-1404492

RESUMO

ABSTRACT Objective: The objective of this study was to evaluate the effect of cigarette smoke (CS) on physical and mechanical properties of ceramic, polycarbonate and alumina ceramic brackets. The null hypothesis tested was that aesthetic brackets would not be influenced by CS. Methods: Ninety aesthetic brackets were allocated to three groups (n = 30): ceramic (GCE), polycarbonate (GCO) and alumina ceramic (GPS). Ten samples of each group were assigned to color and surface roughness analysis, performed before (T0) and after (T1) exposure to CS; and twenty samples were allocated into control and experimental groups (n = 10) (not exposed and exposed to CS, respectively) for shear bond strength test (SBS). Exposure to CS followed an adaptation of the method described by Le Mesurier. Colorimetric reading, surface morphology and roughness, SBS and adhesive remnant index (ARI) were assessed. Statistical analysis comprised independent and paired t-tests, ANOVA/Tukey and Fisher's exact tests (α = 0.05). Results: Changes were observed in brackets' color (NBS: GCE = 2.4; GCO = 1.9; GPS = 2.1), surface roughness (ΔRa: GCE = 1.1 ± 0.8 µm; GCO = 1.9 ± 1.5µm; GPS = -0.3 ± 0.1 µm / ΔRz: GCE = 1.4 ± 1.0 nm; GPS = -0.5 ± 0.1 nm); and SBS (GPS - experimental = 221.8 ± 48.6 N) after exposure to CS (p< 0.05). Conclusions: Exposure, in vitro, of aesthetic brackets to CS resulted in changes of color to darker and more opaque shades, surface roughness alterations, and higher SBS values. ARI scores were not associated with exposure to CS.


RESUMO Objetivo: O objetivo do presente estudo foi avaliar os efeitos da fumaça do cigarro (FC) nas propriedades físicas e mecânicas de braquetes cerâmicos, de policarbonato e de cerâmica de alumina. A hipótese nula testada foi de que os braquetes estéticos não seriam influenciados pela FC. Métodos: Noventa braquetes estéticos foram alocados em três grupos (n = 30): cerâmica (GCE), policarbonato (GCO) e cerâmica de alumina (GPS). Dez amostras de cada grupo foram designadas para análise de cor e rugosidade superficial, realizada antes (T0) e após (T1) exposição à FC, e vinte amostras foram alocadas nos grupos controle e experimental (n = 10) (não expostos e expostos à FC, respectivamente) para o teste de resistência ao cisalhamento (RC). A exposição à FC foi realizada de acordo com o método descrito por Le Mesurier. Leitura colorimétrica, morfologia e rugosidade de superfície, RC e índice de adesivo remanescente (ARI) foram avaliados. A análise estatística foi realizada por meio dos testes t independente e para amostras pareadas, ANOVA/Tukey e teste exato de Fisher (α = 0,05). Resultados: Foram observadas alterações na cor (NBS: GCE = 2,4; GCO = 1,9; GPS = 2,1), rugosidade superficial (ΔRa: GCE = 1,1 ± 0,8 µm; GCO = 1,9 ± 1,5 µm; GPS = -0,3 ± 0,1 µm / ΔRz: GCE = 1,4 ± 1,0 nm; GPS = -0,5 ± 0,1 nm) e RC (GPS - experimental = 221,8 ± 48,6 N) dos braquetes após exposição à FC (p< 0,05). Conclusões: A exposição in vitro de braquetes estéticos à FC resultou em mudanças na cor, para tons mais escuros e mais opacos; alterações na rugosidade superficial e maiores valores de RC. Os resultados do ARI não foram associados à exposição à FC.

6.
Braz. dent. sci ; 25(2): 1-10, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1363628

RESUMO

Objective: The current study aimed to evaluate the effect of diode laser irradiation (980 nm) and warm air drying (50°C) on shear bond strength between Lithium di-silicate (IPS e.max; Ivoclar) and human dentin using both (Etch & Rinse) adhesive, Adper™ Single Bond 2 (3M ESPE) and (Self-etch) adhesive, Single Bond UniversalTM(3M ESPE) before adhesive polymerization. Material and Methods: 54 sound lower molars were sectioned to obtain flat dentinal surfaces. Specimens were divided into 2 equal groups (n=27): Group 1 (ER) and Group 2 (SE) according to bonding approach. Each subgroup was subdivided according to dentin surface treatment into 3 equal subgroups (n=9): Control (Co), Diode laser irradiation (L) and Warm air drying (W). All specimens were adhesively cemented to IPS e.max® CAD discs using RelyX™ Ultimate Clicker™(3M ESPE) resin cement. Samples were then subjected to pre-loading in a thermodynamic manner. All samples were tested for shear bond strength using computer-controlled material testing machine. Data analysis was performed using two-way (ANOVA) (p< 0.05) followed by pair-wise Tukey's post-hoc tests. Results: In (SE) group, the subgroup (W) had the highest shear bond strength values followed by (Co) subgroup and the least was (L) subgroup with statistically significant difference. As for (ER) group, the subgroup (W) had the highest shear bond strength values followed by (Co) subgroup and the least was (L) subgroup with no statistically significant difference. Conclusion: Warm air drying for (SE) bonding approach increased shear bond strength of Lithium di-silicate to human dentin and can be introduced as a new effective protocol.(AU)


Objetivo: o objetivo do estudo atual é avaliar o efeito da radiação do laser de diodo (980nm) e secagem de ar quente (50°C) na resistência ao cisalhamento entre dissilicati de Lítio (IPS e.max; Ivoclar) e a dentina humana usando ambos modelos de adesivos (condicionamento total) Adper™ Single Bond e (auto-condicionante) Single Bond Universal™ (3M ESPE), Single Bond UniversalTM (3M ESPE) antes da fotopolimerização. Material e Métodos: 54 segundos molares inferiores foram selecionados para obter superfícies dentinárias planas. Os espécimes foram divididos em 2 grupos iguais (n=27): grupo 1 (ER) e grupo 2 (SE) de acordo com protocolo de adesividade. Cada grupo foi subdividido de acordo com o tratamento de superfície dentro de 3 subgrupos iguais (n=9): Controle (co), irradiação com laser de diodo (L) e secagem com ar quente (W). Todos os espécimes foram adesivamente cimentados a discos de IPS emax CAD usando RelyX Ultimate Clicker (3M ESPE) cimento resinoso. As amostras foram então submetidas a pré-carregamento de forma termodinâmica. Todas as amostras foram testadas para resistência a cisalhamento usando máquina de teste de materiais controlados por computador. A análise de dados foi realizada usando ANOVA dois fatores (p<0.05) seguindo por testes de Tukey pareado como test post-hoc. Resultados: No grupo (SE), o subgrupo (W) apresentou maiores valores de resistência ao cisalhamento seguindo o subgrupo (Co) é o menor foi o subgrupo (L) com diferença estatisticamente significativa. Já para o grupo (Er), o subgrupo (W) apresentou os maiores valores de resistência ao cisalhamento seguido do grupo (Co) e o menor foi o subgrupo (L) sem diferença estatisticamente significante. Conclusão: a secagem com ar quente para a abordagem de adesividade (Se) aumentou a resistência ao cisalhamento do dissilicato de lítio à dentina humana e poderia ser introduzido como um novo e eficaz protocolo(AU)


Assuntos
Humanos , Adesivos Dentinários , Resistência ao Cisalhamento , Dentina , Lasers de Estado Sólido
7.
Acta odontol. latinoam ; 34(3): 226-232, 2021. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1383409

RESUMO

ABSTRACT The aim of this study was to compare the microshear bond strength of different resin cements to CAD/CAM-created lithium disilicate ceramics after 24 hours and after 1 year (10,000 thermocycles). Forty (40) ceramic bars were subjected to pretreatment comprising airborne abrasion with aluminum oxide particles, etching with 10% hydrofluoric acid and Monobond N application. Bars were divided into 4 groups (n = 10), based on cement type: light-cured Variolink Esthetic LC (VLC) and dual-cured Variolink N (VN) at two different times: after 24 hours and after 1 year. Silicone molds were used to prepare cement cylinders on a ceramic surface. The set was stored in distilled water at 37ºC, for 24 hours or subjected to 10,000 thermocycles. The molds were removed and microshear bond strength was tested. Data were submitted to two-way analysis of variance and Tukey's test (α = 0.05). Based on the comparison between cement values at different aging times (p = 0.035), VN after 24 hours (27.10 ± 0.92) and after 1 year (20.62 ± 1.25) presented significantly higher values than VLC after 24 hours (14.79 ± 0.76) and after 1 year (6.61 ± 0.81). Bond strength recorded for both cements after 24 hours (VN: 27.10 ± 0.92 and VLC: 14.79 ± 0.76) was significantly higher than the one recorded after 1 year (VN: 20.62 ± 1.25 and VLC: 6.61 ± 0.81). The thermocycling reduced the values observed for both investigated cements; bond strength was greater for dual-cure resin cement than for light-cured resin cement.


RESUMO O objetivo nesse estudo foi comparar a resistência de união de diferentes cimentos resinosos à cerâmica de dissilicato de lítio processada por CAD/CAM após 24 horas e após 1 ano (10.000 termociclos). Foram utilizadas 40 barras cerâmicas com tratamento prévio por jateamento com óxido de alumínio, condicionamento com ácido fluorídrico 10% e aplicação do Monobond N. As barras foram divididas em 4 grupos (n=10) de acordo com o tipo de cimento: fotopolimerizável Variolink Esthetic LC (VLC) e dual Variolink N (VN) em diferentes tempos: após 24 horas e 1 ano. Matrizes de silicone foram usadas para preparar cilindros de cimento na superfície cerâmica. O conjunto foi armazenado em água destilada a 37ºC por 24 horas ou submetidos protocolo de termociclagem com 10.000 ciclos. As matrizes foram removidas e o teste de microcisalhamento realizado. Os dados foram avaliados por análise de variância a dois fatores e teste de Tukey (α=0,05). Ao comparar os valores dos cimentos em diferentes tempos de envelhecimento (p=0,035), observou-se que VN, após 24 horas (27,10 ± 0,92) e 1 ano (20,62 ± 1,25) apresentou valores significativamente superior a VLC após 24 horas (14,79 ± 0,76) e 1 ano (6,61 ± 0,81). A resistência para ambos os cimentos após 24 horas (VN: 27,10 ± 0,92 e VLC: 14,79 ± 0,76) foi significativamente superior que 1 ano (VN: 20,62 ± 1,25 e VLC: 6,61 ± 0,81). A termociclagem promoveu diminuição nos valores de ambos os cimentos estudados e o cimento resinoso dual mostrou maior resistência de união que o cimento resinoso fotopolimerizável.

8.
J. health sci. (Londrina) ; 23(4): 277-281, 20211206.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1354021

RESUMO

Abstract In the routine clinical situation, the contamination by blood and/or saliva in restorative procedures can be happen in non-cooperation of the patient in dental office. The aim of the study was to assess in vitro shear bond strength of a resin sealant associated with two types of adhesives contaminated with saliva and blood. Healthy human molars were used and the specimens and the crowns were sectioned in the bucco-lingual direction, thus obtaining two segments of similar proportions (mesial and distal), totaling 60 surfaces, and the surfaces were randomly divided into 4 groups (n = 15). Group I (control) received no type of contamination and the sealant was applied. In group II, the surfaces were contaminated with 10 µl of saliva/blood and the sealant was applied. In group III, the surfaces were contaminated with 10 µl of saliva/blood and the Single Bond total-etch adhesive system was applied followed by application of sealant. In group IV, the surfaces were contaminated with 10 µl of saliva/blood and the Prime & Bond NT total-etch adhesive system was applied followed by the application of sealant. Samples were tested in the universal testing machine and the analysis of shear bond strength was performed. A difference between Group I (12.61MPa) and the other groups was found; Group II (2. 28MPa) was different than Groups III (7.07MPa) and IV (7.79MPa), but Groups III and IV were similar. The application of an adhesive system when there is contamination with saliva/blood is required prior to application of pit and fissure sealants. (AU)


Resumo Na situação clínica de rotina, a contaminação por sangue e/ou saliva em procedimentos restauradores pode ocorrer em pacientes que não colaboram no consultório odontológico. O objetivo do estudo foi avaliar a resistência ao cisalhamento in vitro de um selante de resina associado a dois tipos de adesivos contaminados com saliva e sangue. Foram utilizados molares humanos saudáveis e os espécimes e as coroas foram seccionados na direção bucal-lingual, obtendo assim dois segmentos de proporções semelhantes (mesial e distal), totalizando 60 superfícies, e as superfícies foram divididas aleatoriamente em 4 grupos (n = 15). O Grupo I (controle) não recebeu nenhum tipo de contaminação e o selante foi aplicado. No grupo II, as superfícies foram contaminadas com 10 µl de saliva / sangue e o selante foi aplicado. No grupo III, as superfícies foram contaminadas com 10 µl de saliva / sangue e o sistema adesivo Single-Bond foi aplicado seguindo a aplicação de selante. No grupo IV, as superfícies foram contaminadas com 10 µl de saliva / sangue e o sistema adesivo de ataque total Prime & Bond NT foi aplicado seguido da aplicação de vedante. As amostras foram testadas na máquina de ensaio universal e a análise da resistência à ligação ao cisalhamento foi realizada. Uma diferença entre o Grupo I (12,61MPa) e os outros grupos foi encontrada; O Grupo II (2,28 MPa) foi diferente dos Grupos III (7,07MPa) e IV (7,79 MPa), mas os Grupos III e IV foram semelhantes. A aplicação de um sistema adesivo quando existe contaminação com saliva / sangue é necessária antes da aplicação de selantes de fissura e fissura.

9.
Rev. odontol. UNESP (Online) ; 50: e20210038, 2021. tab, ilus
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1352133

RESUMO

Introduction Fluoride is considered a key element in the remineralization process of tooth enamel. Objective To evaluate the influence of a topical solution of sodium fluoride (NaF) on the shear bond strength of orthodontic brackets and white spot lesions formation. Material and method Sixty bovine teeth were divided into three groups (n=20). Group 1 (Control): shear bond strength; Group 2: shear bond strength after pH cycling; Group 3: shear bond strength after pH cycling and treatment with 0.04% NaF solution. Groups 2 and 3 underwent pH cycling with demineralizing (6hs) and remineralizing (17hs) solutions at pH of 4.3 and 7.0 respectively for 15 days. The specimens were submitted to the shear bond strength and the Adhesive Remnant Index was verified (ARI). The specimens of each group (n=3) were qualitatively analyzed by means of Scanning Electron Microscopy (SEM). Kruskal-Wallis test assessed the shear bond strength and Fisher's exact test evaluated ARI, with significance level of 5%. Result There was no significant difference among the three groups in shear bond strength (p=0.2679). Significant difference was found in ARI (p=0.0199). The frequency of ARI 1 was 55% in group 1, 90% in group 2, and 80% in group 3. SEM showed difference between the enamel and bonding. Group 2 showed structural change of the enamel surface, adjacent to the bond area; and group 3 showed enamel with characteristics similar to those of group 1. Conclusion It was concluded that there was no NaF influence on the bracket shear bond strength and even in low concentrations it prevented the development of areas of demineralization of white spot lesions.


Introdução O flúor é considerado um elemento chave no processo de remineralização do esmalte dentário. Objetivo Este estudo teve como objetivo avaliar a influência da solução tópica de fluoreto de sódio (NaF) na resistência ao cisalhamento da colagem de barquetes ortodônticos durante a formação de lesões de manchas brancas. Material e método Sessenta dentes bovinos foram divididos em três grupos (n=20). Grupo 1 (Controle) - Cisalhamento imediato; Grupo 2 - Cisalhamento após ciclagem de pH; Grupo 3 - Cisalhamento após ciclagem de pH e tratamento com solução de 0,4% de NaF (Ortho Gard, Colgate-Palmolive®). Os Grupos 2 e 3 sofreram ciclagem de pH com soluções de desmineralização e remineralização em pH de 4,3 e 7,0 respectivamente, com ciclos de desmineralização (6 horas) e remineralização (17 horas), durante 15 dias. Os corpos de prova foram submetidos ao teste de resistência de união ao cisalhamento e remanescente adesivo (IRA). Espécimes de cada grupo (n=3) foram analisados qualitativamente por microscopia eletrônica de varredura (MEV). O teste de Kruskal-Wallis foi utilizado para avaliar a resistência ao cisalhamento e o teste exato de Fisher para avaliação do IRA, adotando nível de significância de 5%. Resultado Os resultados não encontraram diferença significativa entre os três grupos quanto à força de cisalhamento (p=0,2679). Diferença significativa foi encontrada no IRA (p = 0,0199). A frequência de IRA 1 foi de 55% no grupo 1, 90% no grupo 2 e 80% no grupo 3. A análise em MEV mostrou diferença entre o esmalte e a área de colagem submetida ao cisalhamento. Grupo 2 apresentou alteração estrutural na superfície do esmalte adjacente à área de colagem, e o Grupo 3 apresentou esmalte com característica semelhante ao do Grupo 1 na área que foi submetida à ciclagem de pH e NaF. Conclusão Concluiu-se que não houve influência do flúor na resistência ao cisalhamento de braquetes. O uso de soluções fluoretadas, ainda que em baixa concentração, preveniu o aparecimento de áreas desmineralizadas e lesões de manchas brancas.


Assuntos
Animais , Fluoreto de Sódio , Microscopia Eletrônica de Varredura , Desmineralização do Dente , Braquetes Ortodônticos , Cárie Dentária , Resistência ao Cisalhamento , Ortodontia , Colagem Dentária , Esmalte Dentário
10.
Dental press j. orthod. (Impr.) ; 26(5): e212118, 2021. tab, graf
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1345936

RESUMO

ABSTRACT Introduction: Various surface pre-treatment methods have been adapted to optimize the bonding between the zirconia ceramics and the orthodontic brackets. Objective: This review is aimed at systematically analyzing the relevant data available in the literature, to find out the most effective and durable bonding protocol. Methods: Database search was conducted in PubMed, Scopus, and ScienceDirect, during September 2020. The review was conducted according to the PRISMA guidelines. Results: Based on the inclusion criteria, 19 articles were selected for qualitative analysis. Meta-analysis could not be performed due to the heterogeneity of the methodology among the studies. Most of the studies scored medium risk of bias. Compared to the untreated surface, surface pretreatments like sandblasting and lasers were advantageous. Primers and universal adhesive were mostly used as an adjunct to the mechanical pretreatment of the zirconia surface. In most studies, thermocycling seemed to lower the shear bond strength (SBS) of the orthodontic brackets. Conclusion: Based on this qualitative review, surface pretreatments with lasers and sandblasting can be suggested to optimize the bracket bond strength. To clarify this finding, meta-analysis is anticipated. Hence, high heterogeneity of the included studies demands standardization of the methodology.


RESUMO Introdução: Diferentes métodos de pré-tratamento da superfície foram adaptados para otimizar a colagem entre os braquetes ortodônticos e as cerâmicas de zircônia. Objetivo: A presente revisão teve como objetivo analisar, de forma sistemática, os dados relevantes na literatura, para buscar o protocolo de colagem mais efetivo e duradouro. Métodos: As buscas foram feitas em setembro de 2020, nas seguintes bases de dados: PubMed, Scopus e ScienceDirect. A revisão foi feita de acordo com as diretrizes do PRISMA. Resultados: Com base nos critérios de inclusão, 19 artigos foram selecionados para análise qualitativa. A metanálise não pôde ser feita, devido à heterogeneidade na metodologia dos estudos incluídos. A maior parte dos estudos apresentou risco de viés moderado. Comparadas às superfícies não tratadas, as superfícies com pré-tratamento usando jateamento ou laser apresentaram vantagem. Primers e adesivos universais foram mais usados como adjuntos ao pré-tratamento mecânico da superfície de zircônia. Na maioria dos estudos, a termociclagem parece ter reduzido a resistência ao cisalhamento dos braquetes ortodônticos. Conclusões: Com base nessa revisão qualitativa, os pré-tratamentos de superfície com laser e jateamento podem ser sugeridos para otimizar a resistência ao cisalhamento dos braquetes. Para esclarecer esse achado, uma metanálise é necessária. Para isso, faz-se necessária a padronização da metodologia, para lidar com a alta heterogeneidade dos estudos incluídos.


Assuntos
Braquetes Ortodônticos , Zircônio , Cerâmica/química , Resistência ao Cisalhamento
11.
Braz. dent. sci ; 24(3): 1-9, 2021. tab, ilus, graf
Artigo em Inglês | BBO - odontologia (Brasil), LILACS | ID: biblio-1281728

RESUMO

Objective: The present study aimed to evaluate the effect of repressing and different surface treatment protocols on the shear bond strength of lithium disilicate glass-ceramics. Material and Methods: A total of 52 lithium disilicate glass-ceramic discs (IPS emax Press, Ivoclar Vivadent) were fabricated using the heat-press technique. The discs were divided into two groups; group (P): discs fabricated from new e.max ingots (n=26), group (R): discs fabricated from reused e.max buttons (n=26). Each group was subdivided into subgroup (E): discs were etched with hydrofluoric acid (9.5%) (n=13), subgroup (S): discs were air-abraded with 110 µm alumina particles. All specimens were subjected to X-ray Diffraction analysis, Scanning Electron Microscope, Energy Dispersive X-Ray, Thermo-Cycling, and Shear Bond Strength Testing. Results: Repressed Etched subgroup (RE) recorded the statistically highest shear bond strength value, followed by the Pressed Etched subgroup (PE), while the statistically lowest shear bond strength value was recorded for the Pressed Air-Abraded subgroup (PS) and Repressed Air-Abraded subgroup (RS). Conclusion: Repressing the leftover buttons for the construction of new lithium disilicate glass-ceramic restorations has no adverse effect on the bond strength of the resin cement to the ceramic. Hydrofluoric acid surface treatment improves the shear bond strength and durability of resin cement bond to both pressed and repressed lithium disilicate glass-ceramic. Air-abrasion cannot be considered as a reliable surface treatment when bonding to lithium disilicate glass-ceramics. (AU)


Objetivo: O presente estudo teve como objetivo avaliar o efeito da reprensagem e de diferentes protocolos de tratamento de superfície na resistência ao cisalhamento de vitrocerâmica de dissilicato de lítio. Materiais e Métodos: Um total de 52 discos de vitrocerâmica de dissilicato de lítio (IPS emax Press, Ivoclar Vivadent) foram fabricadas usando a técnica de prensagem quente. Os discos foram divididos em dois grupos: grupo (P): discos fabricados a partir de novo lingotes de e-max (n=26), grupo (R): discos fabricados a partir de botões de emax reutilizados (n=26). Cada grupo foi subdividido em subgrupo (E): discos condicionados com ácido fluorídrico (9,5%) (n=13), subgrupo (S) discos foram abrasivos com partícula 110 µm de alumínio. Todos os espécimes foram submetidos a analise de difração de raio-x, microscópio eletrônico de varredura, raio-x de energia dispersiva, termociclagem e teste de resistência de cisalhamento. Resultados: O subgrupo Reprensado-condicionado (RE) registrou o valor estatisticamente mais alta em relação a resistência ao cisalhamento, seguido pelo subgrupo Prensado-condicionado (PE), enquanto o valor estatisticamente mais baixo de resistência ao cisalhamento foi o subgrupo Prensado-Jateado (OS) e o subgrupo Reprensado-Jateado (RS). Conclusão: A reprensagem dos botões restantes para a construção de novas restaurações vitrocarâmicas de dissilicato de lítio não apresentou efeitos adversos na resistência de unicãp do cimento resinoso à cerâmica. O tratamento de superfície com ácido fluorídrico melhora a resistência ao cisalhamento e a durabilidade do cimento resinoso para vitrocerâmica de dissilicato de lítio prensada e reprimida. A abrasão por ar não pode ser considerada um tratamento de superfície confiável quanto a colagem da vitrocerâmica de dissilicato de lítio (AU)


Assuntos
Difração de Raios X , Cimentos de Resina , Resistência ao Cisalhamento , Microscopia Eletroquímica de Varredura
12.
Biosci. j. (Online) ; 36(1): 310-315, jan./feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1049253

RESUMO

The aim of this study was to evaluate the effect of different commercial silanes on microshear bond strength of resin cement to lithium disilicate ceramic. Twenty ceramic samples with 10 mm in length, 10 mm wide and 3 mm in thickness were fabricated, etched with 10% hydrofluoric acid for 20 seconds, and divided into 5 groups, according to the commercial silane applied: G1- RelyX Ceramic Primer (3M ESPE), G2- Angelus Silane, G3- Prosil (FGM), G4- Dentsply Silane (Dentsply) and G5- Bis-Silane (Bisco). Silanes were applied in accordance to manufacturers' recommendations. Addition silicone molds with 1 mm in thickness, 10 mm in diameter and 3 perforations with 1 mm in diameter each one, were placed on ceramic and filled with the resin cement RelyX ARC (3M ESPE) in all groups. Light activation was performed with LED Bluephase G2 (Ivoclar Vivadent) at 1200 mW/cm2, for 30 seconds. Samples were maintained in 100% humidity at 37°C for 24 hours and submitted to microshear test. The data (MPa) were submitted to one-way ANOVA and Tukey test (α=0.05). The results obtained for each group were: G1: 22.39±2.99; G2: 23.35±4.08; G3: 26.05±5.46; G4: 18.56±4.09; G5: 25.26±4.10. Statistical analysis showed significantly lower microshear bond strength for G4. Fracture pattern analysis showed predominance of adhesive failures in G1 and G2. G3 and G5 presented higher percentage of cohesive failures in ceramic, and G4 showed mixed, adhesive and cohesive fractures with similar percentages. It was concluded that different silanes showed influence on the lithium disilicate ceramic ­ resin cement bond strength


O objetivo neste estudo foi avaliar o efeito de diferentes silanos comerciais na resistência de união ao microcisalhamento do cimento resinoso à cerâmica de dissilicato de lítio. Foram confeccionadas 20 amostras de cerâmica (10mm de comprimento, 10mm de largura e 3mm de espessura), condicionadas com ácido fluorídrico a 10% por 20 segundos e divididas em 5 grupos, de acordo com o silano aplicado: G1- RelyX Ceramic Primer (3M ESPE), G2- Silano Angelus, G3-Prosil (FGM), G4- Silano Dentsply e G5-Bis-Silane (Bisco). Matrizes de silicone por adição (1 mm de espessura, 10 mm de diâmetro e 3 perfurações com 1 mm de diâmetro) foram colocadas sobre a cerâmica e preenchidas com cimento resinoso RelyX ARC (3M ESPE). A fotoativação foi realizada com LED Bluephase G2 (Ivoclar Vivadent) a 1200 mW/cm2, por 30 segundos. As amostras foram mantidas em 100% de umidade a 37°C por 24 horas e submetidas ao teste de microcisalhamento. Os dados (MPa) (G1: 22,39+2,99; G2: 23,35+4,08; G3: 26,05+5,46; G4: 18,56+ 4,09; G5: 25,26+4,10) foram submetidos a análise de variância e ao teste de Tukey (p<0,05). A análise estatística mostrou valor de resistência de união significantemente menor para G4. A análise do padrão de fratura mostrou predominância de falha adesiva para G1 e G2. G3 e G5 apresentaram maior porcentagem de falha coesiva em cerâmica, e o G4 apresentou fraturas mista, adesiva e coesiva em igual porcentagem. Concluiu-se que os diferentes silanos apresentaram influência na resistência de união do cimento resinoso à cerâmica de dissilicato de lítio


Assuntos
Silanos , Cerâmica , Cimentos Dentários , Resistência ao Cisalhamento , Lítio , Cimento de Silicato , Cimentação , Cimentos de Resina , Porcelana Dentária
13.
Braz. dent. sci ; 23(2): 1-12, 2020. ilus, tab
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1096321

RESUMO

Objective: The objective of this study was to evaluate the effect of immediate dentin sealing, bonding technique, and restorative material on the dentin bond strength of an indirect composite (Solidex) and a resin nanoceramic CAD/CAM block (LAVA Ultimate). Material and Methods: A total of 120 periodontally extracted human molar teeth were abraded horizontally and divided into two groups according to dentin sealing procedures (delayed dentin sealing [DDS] and immediate dentin sealing [IDS]). Next, all teeth were attached to a simulated pulpal pressure mechanism. The specimens were removed from the mechanism after a week. Teeth were subdivided into three groups based on the bonding technique and the type of cement used (Acid-etching + Single Bond Universal + RelyX Ultimate, Single Bond Universal + RelyX Ultimate, RelyX Unicem). Each subgroup was further divided into 2 subgroups according to the type of restorative material used (Solidex [n = 10], Lava Ultimate CAD/ CAM restorative material [n = 10]). Sixty cylindrical samples prepared using both the restorative materials were bonded to the tooth surface according to their group's bonding procedures. All specimens were embedded in chemically cured acrylic resin for shear bond strength test. The shear bond strength (SBS) of the specimens was determined by a universal testing machine with a headspeed of 0.5 mm/min. Results: Three-way ANOVA, independent-sample t test and post hoc Tukey comparison tests (α=0.05) were performed on all data. There were significant differences between the groups. It was found that IDS process significantly increased bond strength in all groups. When dentin bond strengths of tested luting cements were compared, the highest bond strength values were recorded in groups in which the specimens were luted with RelyX Ultimate cement using etch-and-rinse technique. The lowest bond strength values were obtained from groups that used RelyX Unicem as the luting cement. Conclusion: IDS improves bond strength of indirect restorations. Moreover, bonding techniques may have critical effects on the dentin bond strength of indirect restorative materials. The cements' specific affinity levels to both restorative materials and dentin could be considered as the reason of the situation.(AU)


Objetivo: O objetivo deste estudo foi avaliar o efeito do selamento imediato da dentina, da técnica adesiva e do material restaurador na resistência de união à dentina de um compósito indireto (Solidex) e um bloco CAD / CAM de resina nanocerâmica (LAVA Ultimate). Material e Métodos: Um total de 120 dentes molares humanos extraídos por razões periodontais foram desgastados horizontalmente e divididos em dois grupos de acordo com os procedimentos de selamento dentinário (vedação tardia da dentina [DDS] e vedação imediata da dentina [IDS]). Em seguida, todos os dentes foram conectados a um equipamento de pressão pulpar simulada. As amostras foram removidas do equipamento após uma semana. Os dentes foram subdivididos em três grupos, com base na técnica de união e no tipo de cimento utilizado (ataque ácido + Single Bond Universal + RelyX Ultimate, Single Bond Universal + RelyX Ultimate, RelyX Unicem). Cada subgrupo foi então dividido em 2 subgrupos de acordo com o tipo de material restaurador utilizado (Solidex [n = 10], material restaurador Lava Ultimate CAD / CAM [n = 10]). Sessenta amostras cilíndricas preparadas com os dois materiais restauradores foram coladas na superfície do dente de acordo com os procedimentos de adesão do grupo. Todas as amostras foram embebidas em resina acrílica quimicamente ativada para o teste de resistência ao cisalhamento. A resistência de união ao cisalhamento (SBS) das amostras foi determinada por uma máquina de teste universal com uma velocidade de 0,5 mm / min. Resultados: ANOVA de três fatores, teste t de amostra independente e testes de comparação post hoc de Tukey (α = 0,05) foram realizados em todos os dados. Houve diferenças significativas entre os grupos. Verificou-se que o processo IDS aumentou significativamente a força de união em todos os grupos. Quando as forças de união da dentina dos cimentos testados foram comparadas, os valores mais altos de força de união foram registrados nos grupos em que as amostras foram cimentadas com cimento RelyX Ultimate usando a técnica "condicione e lave". Os menores valores de resistência de união foram obtidos de grupos que usaram como cimento o RelyX Unicem. Conclusão: O IDS melhora a força de união das restaurações indiretas. Além disso, as técnicas de união podem ter efeitos críticos na resistência da união à dentina de materiais restauradores indiretos. Os níveis de afinidade específicos dos cimentos para materiais restauradores e dentina podem ser considerados o motivo da situação.(AU)


Assuntos
Cimentação , Desenho Assistido por Computador , Cimentos de Resina , Resistência ao Cisalhamento
14.
Braz. dent. sci ; 23(4): 1-9, 2020. tab, ilus
Artigo em Inglês | BBO - odontologia (Brasil), LILACS | ID: biblio-1122070

RESUMO

Objective: The aim of this study was to evaluate the effect of decontamination methods on shear bond strength of resin cement to translucent monolithic zirconia. Material and Methods: Eighty 4-mol yttria-stabilized tetragonal zirconia polycrystal specimens were fabricated. All specimens were subjected to saliva contamination and divided into four groups (n = 20) according to the decontamination methods: 70% isopropanol (AL); zirclean (ZC); 5.25% sodium hypochlorite (NaOCL); and no cleaning (NC). All specimens were bonded by using self-adhesive resin cement. Half of the specimens in each group (n = 10) were subjected to aging. All specimens were subjected to shear bond strength test in a universal testing machine. Failure modes were evaluated by using a scanning electron microscope (SEM). The data obtained were statistically analyzed by using one-way ANOVA followed by the HSD Tukey test (p < 0.05). Results: ANOVA test revealed a significant difference among the different decontamination methods (p < 0.05). No significant differences were found among NaOCL, ZC, and AL groups as revealed by the HSD Tukey test (p > 0.05). The effect of aging was significantly different in all groups (p < 0.05); whereas, no significant difference was found in group ZC (p > 0.05). The (SEM) analysis showed mixed failures in all groups, except in group NC where only adhesive failure was observed. Conclusion: Saliva contamination during clinical evaluation significantly decreases the shear bond strength between self-adhesive resin cement and translucent monolithic zirconia. The cleaning methods have an impact on improving the bond strength between resin cement and translucent monolithic zirconia (AU)


Objetivo: O objetivo deste estudo foi avaliar o efeito dos métodos de descontaminação na resistência ao cisalhamento entre cimento resinoso e zircônia monolítica translúcida. Material e métodos: Foram fabricados oitenta espécimes policristalinos de zircônia tetragonal estabilizada com ítria a 4 mol. Todas as amostras foram submetidas à contaminação salivar e divididas em quatro grupos (n = 20) de acordo com os métodos de descontaminação: isopropanol a 70% (AL); zircleano (ZC); Hipoclorito de sódio a 5,25% (NaOCL); e sem limpeza (NC). Todas as amostras foram cimentadas utilizando um cimento resinoso autoadesivo. Metade das amostras de cada grupo(n = 10) foram submetidas ao envelhecimento. Todas as amostras foram submetidas ao teste de resistência ao cisalhamento em uma máquina de teste universal. Os módulos de falha foram avaliados usando um microscópio eletrônico de varredura (MEV). Os dados obtidos foram analisados estatisticamente utilizando ANOVA de uma via, seguida pelo teste de HSD Tukey (p < 0,05). Resultados: O teste ANOVA revelou diferença significativa entre os diferentes métodos de descontaminação (p < 0,05). Não foram encontradas diferenças significativas entre os grupos NaOCl, ZC e AL, conforme revelado pelo teste HSD Tukey (p> 0,05). O efeito do envelhecimento foi significativamente diferente em todos os grupos (p < 0,05); enquanto nenhuma diferença significativa foi encontrada no grupo ZC (p > 0,05). A análise (SEM) mostrou falhas mistas em todos os grupos, exceto no grupo NC, onde apenas foi observada falha adesiva. Conclusão: A contaminação por saliva durante a avaliação clínica diminui significativamente a resistência ao cisalhamento entre o cimento resinoso autoadesivo e a zircônia monolítica translúcida. Os métodos de limpeza têm um impacto na melhoria da resistência da união entre o cimento resinoso e a zircônia monolítica translúcida. (AU)


Assuntos
Hipoclorito de Sódio , Descontaminação , Cimentos de Resina , 2-Propanol , Resistência ao Cisalhamento
15.
Braz. dent. sci ; 23(3): 1-12, 2020. tab, ilus, graf
Artigo em Inglês | BBO - odontologia (Brasil), LILACS | ID: biblio-1116104

RESUMO

Objective: The aim of this study is to assess the effect of Er,Cr:YSGG laser on the shear bond strength (SBS) and surface topography of two CAD/CAM ceramic materials bonded with self adhesive resin cement. Material and methods: sixty ceramic CAD/CAM discs were obtained, 30 lithium disilicate (IPS Emax) (Group LD), and 30 hybrid resin ceramic (Vita Enamic) (Group RC). The Slices were allocated into six groups (n=10) according to ceramic material and surface treatment; Group (LD-C): IPS Emax treated with 9% hydrofluoric acid (HF), Groups (LD-L1) and (LD-L2): IPS Emax treated with Er,Cr:YSGG, Group (RC-C): Vita Enamic treated with 9% hydrofluoric acid (HF), Groups (RC-L1) and (RC-L2): Vita Enamic treated with Er,Cr:YSGG laser. The laser parameters and irradiation protocol was 1.5 W (L1) and 2.5 W (L2). All samples were cemented with self-adhesive resin cement and thermocycled for 5000 cycles. The SBS was measured using a universal testing machine and the mean values (MPa) were analyzed using Two-way (ANOVA) (P ≤ 0.05) and Bonferroni's post-hoc test. Results: RC-C (16.55) showed highest SBS followed by LD-C (13.79), which revealed no statistically significant difference with RCP1 (12.33) and RC-P2 (11.2). The lowest SBS values were found with LD-P1 (2.7) and LDP2 (2.1). SEM analysis revealed Vita Enamic to have the highest surface roughness. Fracture pattern analysis showed adhesive failure with IPS Emax groups and mixed failure with Vita Enamic groups. Conclusion: Er,Cr:YSGG laser irradiation with the parameters used did not increase SBS of IPS Emax and Vita Enamic with composite resin compared to HF acid etching (AU)


Objetivo: O objetivo deste estudo é avaliar o efeito do laser Er,Cr:YSGG na resistência ao cisalhamento (SBS) e na topografia superficial de dois materiais cerâmicos CAD/CAM cimentados com cimento resinoso autoadesivo. Material e métodos: foram obtidos sessenta discos cerâmicos CAD/CAM, 30 de dissilicato de lítio (IPS Emax) (Grupo LD) e 30 de resina híbrida (Vita Enamic)(Grupo RC). Os discos foram alocados em seis grupos (n = 10), de acordo como material cerâmico e o tratamento de superfície; Grupo (LD-C): IPS Emaxtratado com ácido fluorídrico (HF) a 9%, Grupos (LD-L1) e (LD-L2): IPS Emaxtratado com Er,Cr:YSGG, Grupo (RC-C): Vita Enamic tratada com ácido fluorídrico (HF) a 9%, Grupos (RC-L1) e (RC-L2): Vita Enamic tratada com laser Er,Cr:YSGG. Os parâmetros do laser e o protocolo de irradiação foram de 1,5 W (L1) e 2,5 W (L2). Todas as amostras foram cimentadas com cimento resinoso autoadesivo e termocicladas por 5000 ciclos. A SBS foi medida usando uma máquina de ensaios universais e os valores médios (MPa) foram analisados usando (ANOVA) a dois fatores (P ≤ 0,05) e teste post-hoc de Bonferroni. Resultados: RC-C (16,55) apresentou maior SBS seguido por LD-C (13,79), que não revelou diferença estatisticamente significante com RCP1(12,33) e RC-P2 (11,2). Os menores valores de SBS foram encontrados comLD-P1 (2,7) e LD-P2 (2,1). A análise por MEV revelou que a Vita Enamic possui maior rugosidade de superfície. A análise do padrão de fratura mostrou falha adesiva nos grupos IPS Emax e falha mista nos grupos Vita Enamic. Conclusão: A irradiação com laser Er,Cr:YSGG com os parâmetros utilizados não aumentou a SBS de IPS Emax e Vita Enamic ao cimento resinoso em comparação com o condicionamento ácido com HF.(AU)


Assuntos
Cimentos de Resina , Cimentos Dentários , Resistência ao Cisalhamento , Materiais Dentários
16.
Acta ortop. bras ; 28(4): 190-194, Jul.-Aug. 2020. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1130765

RESUMO

ABSTRACT Objective: To compare the mechanical properties of the supraspinatus tendon in different age groups using Supersonic Shearwave Imaging (SSI) elastography. Methods: We evaluated 38 healthy individuals of both genders, 20 being in the range of 20 to 35 years and 18 being over 60 years. The shear modulus of the supraspinatus tendon was measured by SSI elastography, always on the right side. Means between age groups were compared and statistically analyzed using the Shapiro-Wilk normality test followed by the student's t-test and were established as a statistically significant value of p ≤ 0.05. Results: A statistically significant difference was observed when the mean values of the shear modulus of the supraspinatus tendon of young adults (23.98 ± 9.94 KpA) were compared with those of older adults (17.92 ± 6.17 KpA). Conclusion: We found a difference between the means of the shear modulus measured by the SSI elastography, showing a significant decrease of the shear modulus with the chronological age progression. Level of Evidence III, Diagnostic Studies - Investigating a Diagnostic Test.


RESUMO Objetivo: Comparar as propriedades mecânicas do tendão supraespinal em diferentes grupos etários, utilizando a elastografia Supersonic Shearwave Imaging (SSI). Métodos: Foram avaliados 38 indivíduos saudáveis de ambos os sexos, sendo 20 na faixa de 20 a 35 anos e 18 acima dos 60 anos de idade. Foi aferido o módulo de cisalhamento do tendão supraespinal por elastografia SSI, sempre do lado direito. As médias entre os grupos etários foram comparadas e analisadas estatisticamente, sendo utilizado o teste de normalidade Shapiro-Wilk seguido do student t-test e estabelecido como valor de significância estatística um p ≤ 0,05. Resultados: Foi evidenciada diferença estatisticamente significativa quando comparadas as médias do módulo de cisalhamento do tendão supraespinal dos adultos jovens (23,98 ± 9,94 KpA) com a dos idosos (17,92 ± 6,17 KpA). Conclusão: Houve diferença entre as médias do módulo de cisalhamento medido pela elastografia com SSI, demonstrando diminuição significativa do módulo de cisalhamento com a progressão da idade cronológica. Nível de Evidência III, Estudos diagnósticos - Investigação de um exame para diagnóstico.

17.
Acta odontol. latinoam ; 33(1): 27-32, June 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1130729

RESUMO

ABSTRACT The aim of this study was to assess the influence of differentpretreatmentapproaches on glass ionomer cement (GIC)bond strength (BS) to dentine. Sixty bovine incisors wereallocated into six groups according to substrate - sound orcariesaffecteddentine; and substrate pretreatmentapproach -no conditioning (control), polyacrylic acid for 10 s andphosphoric acid for 7 s. Teeth in the cariesaffecteddentinegroup were previously submitted to cariogenic pHcyclingchallenge. After dentine pretreatment,according to experi mentalgroups, polyethylene tubes were placed on flat dentinesurfaces and filled with GIC. Teeth were stored in distilledwater for 24 h at 37 °C and then submitted to microshear test(0.5 mm/min). Failure pattern analysis was performed understereomicroscope (400x). Data were analysed using twowayANOVA and Tukey's test (α=5%). Statistically significantdifferences were found for the pretreatmentapproach,regardless of substrate (p<0.001). The polyacrylic acid groupand control group had similar BS values, and were both betterthan the phosphoric acid group. In general, GIC had betterbonding performance in sound dentine than in cariesaffecteddentine. In conclusion, dentine pretreatmentwith polyacrylicacid did not improve the performance of GIC restoration onclinically relevant substrates.


RESUMO O objetivo deste estudo foi avaliar a influência de diferentesprétratamentosna resistência de união (RU) de cimentos deionômero de vidro (CIV) a dentina. Sessenta incisivos bovinosforam alocados em 6 grupos de acordo com o substrato -hígido ou cariado; e com a abordagem de prétratamento-sem condicionamento (controle), ácido poliacrílico por 10 s, eácido fosfórico por 7 s. Os dentes pertencentes aos grupos dedentina cariada foram previamente submetidos ao desafiocariogênico por meio da ciclagem de pH. Após o prétratamentoda dentina, de acordo com os grupos experimentais,tubos de polietileno foram colocados sobre superfícies planas dedentina e preenchidos com CIV. Os dentes foram armazenadosem água destilada por 24 h a 37°C e então submetidos ao testede microcisalhamento (0,5 mm/min). A análise do padrão defratura foi realizada em estereomicroscópio (400x). Os dadosobtidos foram analisados usando ANOVA de dois fatores e testede Tukey (α=5%). Diferença estatisticamente significante foiencontrada para as diferentes abordagens de prétratamento,independente do substrato (pp<0,001). Aplicação de ácidopoliacrílico resultou em valores de RU similares aos do grupocontrole. Entretanto, ambos os grupos mostraram um melhordesempenho quando comparado a aplicação de ácidofosfórico. De forma geral, CIV apresentou melho5 desempenhoadesivo em dentina sadia quando comparada a dentinacariada. Em conclusão, o prétratamentoem dentina comácido poliacrílico não melhora o desempenho das restauraçõesde CIV em substratos clinicamente relevantes.


Assuntos
Animais , Bovinos , Resinas Acrílicas/farmacologia , Colagem Dentária/métodos , Dentina/efeitos dos fármacos , Cimentos de Ionômeros de Vidro/química , Teste de Materiais , Infiltração Dentária/prevenção & controle , Dentina/patologia , Dentina/diagnóstico por imagem
18.
Braz. dent. sci ; 22(2): 275-280, 2019. tab
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-997492

RESUMO

Objective: to evaluate the effect of aluminum oxide sandblasting (AOS), argon plasma application (APL) and their combination (AOS+APL) on the shear bond strength (SBS) of dual-cure resin cement (Panavia F 2.0, Kuraray Noritake) to two zirconia-based ceramics (Lava, 3M ESPE and Katana, Kuraray Noritake). Material and Methods: One hundred twenty zirconia plates (13 mm in length X 5 mm in width X 1 mm in thickness) were prepared and treated according to the following treatments: 1- AOS, 2- APL,3- AOS+APL and 4- no treatment (control). After treatments, resin cement cylinders (1.4 mm in diameter x 1 mm in height) bonded to zirconia surface were obtained by filling up the silicon matrix. The shear bond test was performed following storage of the samples for 24 hours and one year. Bond strength values were recorded in MPa and the data were analyzed by three-way ANOVA and Tukey post-hoc test (preset alpha of 0.05). Results: In general, AOS and AOS +APL showed the higher SBS. After one-year storage, SBS of the resin cement to the Katana zirconia did not reduce, regardless of the zirconia surface treatment. Conclusion: AOS alone was able to increase the SBS of the resin cement to both zirconia ceramics compared to control and SBS remained stable after one year depending on type of zirconia ceramic. (AU)


Objetivo: avaliar o efeito do jateamento de óxido de alumínio (AOS), aplicação de plasma de argônio (APL) e sua combinação (AOS + APL) na resistência ao cisalhamento (SBS) do cimento resinoso dual (Panavia F 2.0, Kuraray Noritake) a duas cerâmicas à base de zircônia (Lava, 3M ESPE e Katana, Kuraray Noritake). Material e Métodos: Cento e vinte placas de zircônia (13 mm de comprimento X 5 mm de largura X 1 mm de espessura) foram preparadas e tratadas de acordo com os seguintes tratamentos: 1- AOS, 2- APL, 3- AOS + APL e 4 - sem tratamento (controle). Após realizados os tratamentos, com a utilização de uma matriz de silicone (1,4 mm de diâmetro x 1 mm de altura) foram confeccionados cílindros de cimento resinoso na superfície da zircônia. O teste de cisalhamento foi realizado após o armazenamento das amostras por 24 horas e um ano. Os valores de resistência de união foram registrados em MPa e os dados foram analisados por ANOVA de três fatores e teste post-hoc de Tukey (alfa de 0,05). Resultados: Em geral, AOS e AOS + APL apresentaram a maior SBS. Após um ano de armazenamento, o SBS do cimento resinoso para a zircônia Katana não reduziu, independentemente do tratamento da superfície da zircônia. Conclusão: AOS isoladamente foi capaz de aumentar a SBS do cimento resinoso para ambas as zircônias em comparação com o controle e a SBS permaneceu estável após um ano, dependendo do tipo de zircônia. (AU)


Assuntos
Cerâmica , Abrasão Dental por Ar , Resistência ao Cisalhamento , Gases em Plasma
19.
J. health sci. (Londrina) ; 21(5): https://seer.pgsskroton.com/index.php/JHealthSci/article/view/6460, 20/12/2019.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1051596

RESUMO

The evolution of dental materials and the improvement of ceramic systems stimulated the increased use of Y-TZP zirconia-based ceramics. Despite the excellent mechanical performance, this material has low adhesion potential. The objective of this work was to evaluate the surface treatments and resin cements influence on bond strength between Y-TZP zirconia and composite resin interface. A total of 60 blocks of Y-TZP zirconia (3x8x8mm) were prepared and divided into 3 groups according to the surface treatments: (C) control - extra fine diamond bur, (J) sandblasting with Al2O3 and (JP) sandblasting with Al2O3 + ceramic primer. Each group was subdivided into two groups according to type of resin cement used for cementing composite resin discs (2mm thick x 5mm diameter): self-adhesive and conventional (n=10). The samples were stored in distilled water for 24 hours at 37±1°C in a incubator and subsequently submitted to the shear bond test to determine the bond strength (RU). There was no significant difference in RU among the surface treatments when using conventional resin cement. For the self-adhesive resin cement, Al2O3 blasting and Al2O3 + primer blasting increased the RU but did not present significant differences between them (p<0.05). Comparing the cements, it was observed that regardless of the surface treatment, the highest values were for the self-adhesive resin cement (p<0.05). Application of the primer after blasting with Al2O3 did not increase RU. (AU)


A evolução dos materiais odontológicos e o aprimoramento dos sistemas cerâmicos impulsionaram o aumento da utilização da cerâmica a base de zircônia Y-TZP. Apesar do excelente desempenho mecânico, este material apresenta baixo potencial de adesão. O objetivo deste trabalho foi avaliar a influência dos tratamentos de superfícies e dos cimentos resinosos na resistência de união entre a interface zircônia Y-TZP e resina composta. Foram confeccionados 60 blocos de zircônia Y-TZP (3x8x8 mm) e divididos em 03 grupos de acordo com os tratamentos de superfícies que receberam: (C) controle - ponta diamantada extrafina, (J) jateamento com Al2O3 e (JP) jateamento com Al2O3 + primer cerâmico. Cada grupo foi subdividido em dois novos grupos de acordo com tipo de cimento resinoso utilizado para cimentação de discos de resina composta (2mm de espessura x 5mm de diâmetro): autoadesivo e resinoso convencional (n=10). As amostras foram armazenadas em água destilada por 24 horas a 37±1°C em estufa e posteriormente submetidas ao teste de cisalhamento para averiguar a resistência de união (RU). Não houve diferença significativa na RU entre os tratamentos de superfície quando utilizado o cimento resinoso convencional. Para o cimento resinoso autoadesivo o jateamento com Al2O3 e o jateamento de Al2O3 + primer aumentaram a RU porém não apresentaram diferenças significativas entre si (p<0,05). Comparando os cimentos observou-se que, independente do tratamento de superfície, os maiores valores foram para o cimento resinoso autoadesivo (p<0,05). A aplicação do primer após o jateamento com Al2O3 não proporcionou aumento da RU. (AU)

20.
J. Oral Investig ; 8(2): 49-58, jul.-dez. 2019. ilus, tab, graf
Artigo em Português | BBO - odontologia (Brasil) | ID: biblio-1007257

RESUMO

Objetivos: O condicionamento da superfície dos tecidos dentários duros com ácido fosfórico 35% é normalmente utilizado para fornecer retenção micromecânica para adesivos odontológicos. Quando lavado da superfície, o ácido pode gerar gosto amargo e desagradável ao paladar do paciente. O objetivo deste estudo foi analisar o efeito da adição de um agente aromatizante à composição do gel de ácido fosfórico 35% e investigar se existe alteração de características fundamentais deste material, como sua capacidade de desmineralizar a superfície dentária. Métodos: Além de um grupo controle (sem flavorizante), foram testados grupos de ácido fosfórico 35% com a adição de 0,5% ou 3% do aromatizante (Aroma Abacaxi Pó; Bio Green Ingredients). Foram realizadas análises de viscosidade, estabilidade do pH e de desmineralização da superfície de esmalte condicionada por microscopia eletrônica de varredura, além de teste de resistência de união ao esmalte por microcisalhamento. Resultados: Apesar dos grupos apresentarem pequenas diferenças entre si, nenhuma das alterações se mostrou significativa, exceto o aumento da viscosidade do gel contendo 3% do aromatizante. Conclusões: A adição de agente aromatizante ao gel condicionador de ácido fosfórico 35% parece ser alternativa viável para reduzir os problemas relacionados ao contato com o sabor desagradável do material, uma vez que não promoveu alteração negativa significativa nas características e comportamento do ácido(AU)


Objectives: Etching of dental hard tissues surfaces with 35% phosphoric acid is usually used to provide micromechanical interlocking with dental adhesives. When washed from the surface, the acid can cause a bitter taste unpleasant to the patient. The aim of this study was to analyze the effect of the addition of a flavoring agent to 35% phosphoric acid gel and investigate whether there is change in the fundamental characteristics of this material, including its ability to demineralize dental surfaces. Methods: In addition to a control group (without flavoring agent), groups were tested with the addition of 0.5% or 3% of the flavoring compound (pineapple flavor powder, Bio Green Ingredients) to 35% phosphoric acid. Analyses of viscosity, pH stability and demineralization of enamel surfaces by scanning electron microscopy were carried out, as well microshear bond strength to enamel. Results: Although the groups had minor differences among themselves, none of the changes were significant, except the increased viscosity of the gel containing 3% of the flavoring agent. Conclusions: The addition of flavoring agent to 35% phosphoric acid gel conditioner seems to be a viable alternative to reduce the problems related to contact with the unpleasant taste of the material, since it promoted no negative changes in the characteristics and behavior of the acid(AU)


Assuntos
Ácidos Fosfóricos , Materiais Dentários , Aromatizantes , Condicionamento Ácido do Dente , Desmineralização do Dente , Resistência ao Cisalhamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa