RESUMO
The development of island construction concrete can serve as a basis for the development and utilization of island resources. Complying with the principle of using local materials to configure seawater coral aggregate concrete (SCAC) that is able to meet the requirements of island and reef engineering construction could effectively shorten the construction period and cost of island and reef engineering construction. In this paper, quasi-static mechanical experiments and dynamic mechanical experiments were carried out on SCAC with different limestone powder contents. High-speed photography technology and Digital Image Correlation (DIC) were used to monitor the dynamic failure process and strain field of SCAC, and the influence of limestone powder content on the dynamic and static mechanical properties of SCAC was investigated. The results showed that, when the limestone powder content was 20% and 16%, the quasi-static compressive strength and quasi-static tensile strength exhibited the best improvement. Additionally, with increasing limestone powder content, the dynamic tensile strength of SCAC first showed and increasing trend and then a decreasing trend, reaching its maximum value when the limestone powder content was 16%. Moreover, the maximum strain value of SCAC with the same limestone powder content increased with increasing strain rate grade, showing an obvious effect on strain rate.
RESUMO
The purpose of this study was to assess the inter-observer and intra-observer reproducibility of the interpretation of CT arthrography and plain X-rays for scapholunate advanced collapse (SLAC), scaphoid non-union advanced collapse (SNAC) and scaphoid chondrocalcinosis advanced collapse (SCAC) wrist conditions, as well as the clinical relevance of these imaging modalities. The CT and X-rays images were reviewed twice in a blinded and randomized manner by two experienced orthopedic surgeons specialized in hand surgery, two orthopedic surgery residents and two experienced radiologists specialized in bone and joint imaging. Cohen's kappa and Fleiss' kappa coefficients were used to analyze the reproducibility of interpretation of the radiological examinations. With CT arthrography, the overall diagnosis was often a problem, in terms of both inter- or intra-observer reproducibility. The assessment of the joint line appeared to be fairly reproducible for each observer but was poorly reproducible between different observers. Plain X-rays are not sufficient to assess cartilage quality in degenerative wrist disease. CT arthrography is a reliable examination, but its interpretation is not always standardized. Diagnostic arthroscopy may be justified in doubtful cases.