Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(17)2024 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-39275483

RESUMO

A technique for solving the one-port closed coaxial transmission line sample holder scattering equation for complex permittivity inversion for lossy materials is presented. A non-linear least-squares procedure is used for the determination of parameters for the specification of the spectral functional form of the complex permittivity. The method allows for accurate retrieval of many low- and high-permittivity dielectric materials in the frequency range of 1 GHz to 3 GHz inserted into the coaxial cell. Using this method, the complex permittivity of a number of liquids and a Maltese soil known as Bajjad soil have been extracted by measurements using a short terminated coaxial transmission line sample holder. The proposed novel inversion method is mainly based on the reflection coefficient of the test material. The measured results of the complex permittivity of liquid dielectrics such as ethanol, methanol, and TX100 are validated and compared with previously published data obtained from measurements made by the National Physical Laboratory (NPL) using a two-port measurement setup made with the same commercial coaxial transmission line sample holder used in the one-port setup. Since the technique allows broadband measurements, it has been used to characterise the soil dielectric spectrum in the frequency range of 1-3 GHz, which is also compared with results from a two-port setup of the same coaxial line. The experimental results are a validation of the proposed approach for different types of materials.

2.
AAPS PharmSciTech ; 20(1): 7, 2018 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-30560468

RESUMO

Oromucosal film preparations have gained popularity in pharmaceutical research and development. Therefore, oral films have been integrated into the monograph "oromucosal preparations" of the European Pharmacopeia in 2012. Regulatory authorities explicitly demand dissolution studies for films, but neither refer to suitable methods nor established specifications. Test methods described in the literature are often limited to immediate release formulations or not applicable to investigate the drug release of films with prolonged release profiles considering the different stages of gastrointestinal transit. The aims of this study were to develop a dissolution test method, which is suitable to investigate the drug release of film preparations with immediate as well as modified release profiles and to explore the potential of the test setup considering some physiological characteristics. Therefore, a conventional flow-through cell was equipped with in-house built sample holders. Three-dimensional printing technology was used for prototyping one of the sample holders. Four different types of films were investigated, such as ODFs with immediate (ODFIR) and prolonged release (ODFPR) characteristics as well as a double-layer film (ODFDL), produced with a water-insoluble shielding layer. Anhydrous theophylline was used as a model drug for all film types. Introducing special fixtures for oral films to a conventional flow-through cell enables successful determination of the drug release behavior of oral film preparations with immediate as well as modified release properties. Investigating ODFDL, the application of film sample holders with backing plates such as film sample holder with backing plate (FHB) and 3D printed film sample holder (FH3D) showed prolonged release profiles with 14.6 ± 1.30% theophylline dissolved within 2 h for FHB compared to 92.9 ± 3.33% for the film sample holder without backing plate (FH). This indicates their suitability to examine the integrity of the shielding layer. The application of the backing plate further decreased the drug release of ODFPR < 315 to 61.0 ± 1.69% dissolved theophylline within 2 h using FHB compared to 82.3 ± 0.74% using FH, due to a reduced ODF surface exposed to the dissolution medium. The potential of the dissolution test setup to consider physiological conditions of the human gastrointestinal transit was investigated by applying different flow rates and media compositions to simulate conditions within the oral cavity, stomach, and intestine. For the application of a low flow rate of 1 ml/min, comparable to the salivary flow within the oral cavity, decreased theophylline release was observed, while similar release profiles were obtained for flow rates between 2 and 8 ml/min. Substantial impact on the theophylline release was exerted by varying the composition of the dissolution medium. Since the drug release from ODFPR is controlled by diffusion through a water-insoluble matrix, ion species and concentration strongly affect the release behavior. In the future, IVIVC studies have to be performed to explore, whether obtained data can be used to predict drug release behavior of ODFs during the human gastrointestinal transit.


Assuntos
Sistemas de Liberação de Medicamentos , Administração Oral , Composição de Medicamentos/métodos , Liberação Controlada de Fármacos , Humanos , Solubilidade , Teofilina/química , Água/química
3.
Biochem Biophys Res Commun ; 463(4): 1141-3, 2015 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-26093294

RESUMO

A major hurdle to the widespread application of light sheet microscopy is the lack of versatile and non-intrusive sample holders that are adaptable to a variety of biological samples for live imaging. To overcome this limitation, we present herein the application of 3D printing to the fabrication of a fully customizable casting kit. 3D printing enables facile preparation of hydrogel sample holders adaptable to any shape and number of specimen. As an example, we present the use of this device to produce a four-sample holder adapted to parallel live monitoring of multicellular tumor spheroid growth. To share our solution with the light sheet microscopy community, all files necessary to produce or customize sample holders are freely available online.


Assuntos
Microscopia/métodos , Impressão Tridimensional , Manejo de Espécimes/instrumentação
4.
Ultramicroscopy ; 267: 114037, 2024 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-39378698

RESUMO

The automated and autonomous cryogenic transmission electron microscopy (Cryo-EM) demands a sample holder capable of maintaining temperatures below 10 K with precise control, long holding times, and minimal helium use. Rising to this challenge, we initiated an ambitious project to develop a novel closed-cycle cryocooler-based cryogenic sample holder that operates without the use of liquid helium and the consumption of gaseous helium. This article presents the design, construction, and experimental testing of the initial prototype, which achieves an ultimate temperature of 5.6 K with exceptional stability close to 1mK, while providing a wide temperature control range from 295 K to 5.6 K, marking a clear advancement in cryo-EM holder development. While the prototype was not designed for atomic resolution imaging and thus lacks a sturdy support system to mitigate mechanical vibrations from the cryocooler's pulsed tube, this innovative approach successfully demonstrates proof of concept. It offers unprecedented capabilities for state-of-the-art cryogenic microscopy and microanalysis in materials and biological sciences.

5.
J Microsc ; 251(2): 128-32, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23691992

RESUMO

Single Plane Illumination Microscopy is an emerging and powerful technology for live imaging of whole living organisms. However, sample handling that relies on specimen embedding in agarose or gel is often a key limitation, especially for time-lapse monitoring. To address this issue, we developed a new concept for a holder device allowing us to prepare a sample container made of hydrogel. The production process of this holder is based on 3D printing of both a frame and casting devices. The simplicity of production and the advantages of this versatile new sample holder are shown with time-lapse recording of multicellular tumour spheroid growth. More importantly, we also show that cell division is not impaired in contrast to what is observed with gel embedding. The benefit of this new holder for other sample types, applications and experiments remains to be evaluated, but this innovative concept of fully customizable sample holder preparation potentially represents a major step forward to facilitate the large diffusion of single plane illumination microscopy technology.


Assuntos
Imageamento Tridimensional/instrumentação , Iluminação/instrumentação , Microscopia/instrumentação , Imagem com Lapso de Tempo/instrumentação , Linhagem Celular Tumoral , Humanos , Imageamento Tridimensional/métodos , Iluminação/métodos , Microscopia/métodos , Imagem com Lapso de Tempo/métodos
6.
Talanta ; 258: 124474, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36963150

RESUMO

An apparatus and methodology for variable temperature infrared spectroscopy measurements of neat samples contained in a button sample holder are described. Sample heating and cooling are achieved by applying voltage to stacked Peltier thermoelectric devices. Between 0 and 150 °C, samples can be heated and cooled at 2 °C s-1 rates, facilitating temperature step heating/cooling profiles with minimal delay between isothermal infrared spectrum measurements. Examples of correlating temperature-dependent spectral variations with specific sample changes are provided for α-quartz heating/cooling, ibuprofen melting, and acetylsalicylic acid thermal decomposition. Trends in α-quartz infrared spectra obtained with a step heating/cooling temperature profile are used to evaluate spectrum measurement reproducibility. Detection of vibration band intensity variations of less than 1% resulting from a 10 °C sample temperature increment illustrates the measurement sensitivity. By comparing infrared spectra obtained at different temperatures, reversible and irreversible sample changes are identified. Infrared spectra acquired during linear ramp heating are employed to determine the ibuprofen melting point, which confirms the temperature measurement accuracy of the apparatus. Selective analysis is demonstrated by determining isoconversion effective activation energies for processes involved in the thermal decomposition of the acetylsalicylic acid component of a commercial pharmaceutical tablet.

7.
Anal Chim Acta ; 1198: 339558, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35190124

RESUMO

An apparatus and methodology are described that can be used for variable temperature infrared spectroscopy measurements of liquids and powders. Neat samples placed in a stainless steel button sample holder are heated and cooled by applying voltage to a Peltier thermoelectric device. Temperatures between -50 and 100 °C can be attained with the apparatus. By moderately cooling volatile liquids to slow evaporation, the time available for spectrum measurements is substantially increased. Reproducible volatile liquid infrared spectra measured at 10 °C resemble thin film transmittance spectra. Various sample temperature profiles can be created by linking heating and cooling segments to form customized sequences. Measurements made during linearly varying temperature ramps reveal temperature-dependent variations that can be correlated with specific sample structure changes. Difference spectra derived from isothermal measurements made during temperature steps permit discrimination between reversible and irreversible sample changes. Results obtained by using different programmed heating/cooling profiles to monitor the temperature-dependent changes in pure kaolinite and montmorillonite containing 15% (w/w) acetylsalicylic acid are presented to demonstrate the operation and sensitivity of the apparatus and methodology.


Assuntos
Temperatura Baixa , Calefação , Temperatura Alta , Espectrofotometria Infravermelho , Temperatura
8.
Materials (Basel) ; 15(2)2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35057212

RESUMO

Steadily growing interest in magnetic characterization of organic compounds for therapeutic purposes or of other irregularly shaped specimens calls for refinements of experimental methodology to satisfy experimental challenges. Encapsulation in capsules remains the method of choice, but its applicability in precise magnetometry is limited. This is particularly true for minute specimens in the single milligram range as they are outweighed by the capsules and are subject to large alignment errors. We present here a completely new experimental methodology that permits 30-fold in situ reduction of the signal of capsules by substantially restoring the symmetry of the sample holder that is otherwise broken by the presence of the capsule. In practical terms it means that the standard 30 mg capsule is seen by the magnetometer as approximately a 1 mg object, effectively opening the window for precise magnetometry of single milligram specimens. The method is shown to work down to 1.8 K and in the whole range of the magnetic fields. The method is demonstrated and validated using the reciprocal space option of MPMS-SQUID magnetometers; however, it can be easily incorporated in any magnetometer that can accommodate straw sample holders (i.e., the VSM-SQUID). Importantly, the improved sensitivity is accomplished relying only on the standard accessories and data reduction method provided by the SQUID manufacturer, eliminating the need for elaborate raw data manipulations.

9.
Ultramicroscopy ; 230: 113372, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34479040

RESUMO

Signal optimization for transmission Kikuchi diffraction (TKD) measurements in the scanning electron microscope is investigated by a comparison of different sample holder designs. An optimized design is presented, which uses a metal shield to efficiently trap the electron beam after transmission through the sample. For comparison, a second holder configuration allows a significant number of the transmitted electrons to scatter back from the surface of the sample holder onto the diffraction camera screen. It is shown that the secondary interaction with the sample holder leads to a significant increase in the background level, as well as to additional noise in the final Kikuchi diffraction signal. The clean TKD signal of the optimized holder design with reduced background scattering makes it possible to use small signal changes in the range of 2% of the camera full dynamic range. As is shown by an analysis of the power spectrum, the signal-to-noise ratio in the processed Kikuchi diffraction patterns is improved by an order of magnitude. As a result, the optimized design allows an increase in pattern signal to noise ratio which may lead to increase in measurement speed and indexing reliability.

10.
Biomedicines ; 9(11)2021 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-34829897

RESUMO

The controlled release of antibiotics prevents the spread of pathogens and thereby improves healing processes in regenerative medicine. However, high concentrations may interfere with healing processes. It is therefore advantageous to use biodegradable materials for a controlled release. In particular, multilayer materials enable differential release at different surfaces. For this purpose, collagen sheets of different properties can be bonded by photochemical crosslinking. Here, we present the development and application of an easily accessible, additively manufactured sample holder to study the controlled release of vancomycin from modularly assembled collagen laminates in two directions. As proof-of-concept, we show that laminates of collagen sheets covalently linked by rose bengal and green light crosslinking (RGX) can be tightly inserted into the device without leakage from the upper to lower cavity. We used this sample holder to detect the release of vancomycin from symmetrically and asymmetrically loaded two-layer and three-layer collagen laminates into the upper and lower cavity of the sample holder. We show that these collagen laminates are characterized by a collagen type-dependent vancomycin release, enabling the control of antibiotic release profiles as well as the direction of antibiotic release.

11.
Ultramicroscopy ; 214: 113010, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32408179

RESUMO

We present a custom-made sample holder system for use in Elmitec Low Energy and PhotoEmission Electron Microscopes. It consists of two different sample holder bodies: one with a filament for high temperature measurements (up to more than 1500 K) and the other with integrated electromagnets for the in-situ application of in-plane/out-of-plane small magnetic fields. The sample is placed on a platelet which can be transferred between the two holders. This opens up new possibilities for the preparation of samples at high temperatures and investigation of their behavior under applied magnetic fields without leaving the ultra high vacuum system.

12.
Micromachines (Basel) ; 11(2)2020 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-32024035

RESUMO

This paper demonstrates a 3D microlithography system where an array of 5 mm Ultra Violet-Light Emitting Diode (UV-LED) acts as a light source. The unit of the light source is a UV-LED, which comes with a length of about 8.9 mm and a diameter of 5 mm. The whole light source comprises 20 × 20 matrix of such 5 mm UV-LEDs giving a total number of 400 LEDs which makes it a very favorable source with a large area for having a batch production of the desired microstructures. This light source is able to give a level of precision in microfabrication which cannot be obtained using commercial 3D printers. The whole light source performs continuous rotational movement once it is turned on. This can also move up and down in a vertical direction. This multidirectional light source also comprises a multidirectional sample holder. The light source teaming up with the multidirectional sample holder highly facilitates the process of fabrication of a huge range of 3D structures. This article also describes the different levels of characterization of the system and demonstrates several fabricated 3D microstructures including high aspect ratio vertical micro towers, twisted turbine structures, triangles, inclined pillar 'V' structures, and hollow horn structures as well.

13.
Ultramicroscopy ; 190: 1-11, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29655973

RESUMO

Electron cryotomography is able to visualize macromolecular complexes in their cellular context, in a frozen-hydrated state, and in three dimensions. The method, however, is limited to relatively thin samples. Cryo-focused ion beam (FIB) milling is emerging as a powerful technique for sample thinning prior to cryotomography imaging. Previous cryo-FIB milling reports utilized custom-built non-standard equipment. Here we present a workflow and the required commercially available instrumentation to either implement the method de novo, or as an upgrade of pre-existing dual beam milling instruments. We introduce two alternative protocols and the respective sample holders for milling. The "bare grid holder" allows for milling on plain grids, having the advantage of enabling relatively shallow milling angles for wedge geometries. The "Autogrid holder" is designed for milling grids clamped into a mechanical support ring (Autogrid), resulting in increased stability for lamella geometries. We applied the workflow to prepare samples and record high-quality tomograms of diverse model organisms, including infected and uninfected HeLa cells, amoebae, yeast, multicellular cyanobacteria, Pseudomonas aeruginosa and Escherichia coli cells. The workflow will contribute to the dissemination of electron cryotomography of cryo-FIB milled samples in the biological sciences.


Assuntos
Microscopia Crioeletrônica/métodos , Tomografia com Microscopia Eletrônica/métodos , Íons/química , Linhagem Celular Tumoral , Elétrons , Células HeLa , Humanos , Microscopia Eletrônica de Transmissão/métodos , Fluxo de Trabalho
14.
Acta Crystallogr D Struct Biol ; 73(Pt 10): 829-840, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28994412

RESUMO

Most of the sample holders currently used in macromolecular crystallography offer limited storage density and poor initial crystal-positioning precision upon mounting on a goniometer. This has now become a limiting factor at high-throughput beamlines, where data collection can be performed in a matter of seconds. Furthermore, this lack of precision limits the potential benefits emerging from automated harvesting systems that could provide crystal-position information which would further enhance alignment at beamlines. This situation provided the motivation for the development of a compact and precise sample holder with corresponding pucks, handling tools and robotic transfer protocols. The development process included four main phases: design, prototype manufacture, testing with a robotic sample changer and validation under real conditions on a beamline. Two sample-holder designs are proposed: NewPin and miniSPINE. They share the same robot gripper and allow the storage of 36 sample holders in uni-puck footprint-style pucks, which represents 252 samples in a dry-shipping dewar commonly used in the field. The pucks are identified with human- and machine-readable codes, as well as with radio-frequency identification (RFID) tags. NewPin offers a crystal-repositioning precision of up to 10 µm but requires a specific goniometer socket. The storage density could reach 64 samples using a special puck designed for fully robotic handling. miniSPINE is less precise but uses a goniometer mount compatible with the current SPINE standard. miniSPINE is proposed for the first implementation of the new standard, since it is easier to integrate at beamlines. An upgraded version of the SPINE sample holder with a corresponding puck named SPINEplus is also proposed in order to offer a homogenous and interoperable system. The project involved several European synchrotrons and industrial companies in the fields of consumables and sample-changer robotics. Manual handling of miniSPINE was tested at different institutes using evaluation kits, and pilot beamlines are being equipped with compatible robotics for large-scale evaluation. A companion paper describes a new sample changer FlexED8 (Papp et al., 2017, Acta Cryst., D73, 841-851).


Assuntos
Cristalografia/instrumentação , Desenho de Equipamento , Robótica/instrumentação , Tamanho da Amostra , Síncrotrons
15.
J Magn Reson ; 269: 157-161, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27323280

RESUMO

Electrochemical cells contain electrically conductive components, which causes various problems if such a cell is analyzed during operation in an EPR resonator. The optimum cell design strongly depends on the application and it is necessary to make certain compromises that need to be individually arranged. Rapid prototyping presents a straightforward option to implement a variable cell design that can be easily adapted to changing requirements. In this communication, it is demonstrated that sample containers produced by 3D printing are suitable for EPR applications, with a particular emphasis on electrochemical applications. The housing of a high temperature polymer electrolyte fuel cell (HT-PEFC) with a phosphoric acid doped polybenzimidazole membrane was prepared from polycarbonate by 3D printing. Using a custom glass Dewar, this fuel cell could be operated at temperatures up to 140°C in a standard EPR cavity. The carbon-based gas diffusion layer showed an EPR signal with a characteristic Dysonian line shape, whose evolution could be monitored in-operando in a non-invasive manner.

16.
Ultramicroscopy ; 159 Pt 3: 508-12, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26028508

RESUMO

We investigate laser induced magnetic switching in a ferrimagnetic thin film of Tb22Fe69Co9 by PEEM. Using a small laser beam with a spot size of 3-5 µm in diameter in combination with high resolution magnetic soft X-ray microscopy we are able to discriminate between different effects that govern the microscopic switching process, namely the influence of the laser heating, of the helicity dependent momentum transfer, and of the dipolar coupling. Applying a sequence of femtosecond laser pulses to a previously saturated TbFeCo film leads to the formation of ring shaped magnetic structures in which all three effects can be observed. Laser helicity assisted switching is only observed in a narrow region within the Gaussian profile of the laser spot. Whereas in the center of the laser spot we find clear evidence for thermal demagnetization and in the outermost areas magnetic switching is determined by dipolar coupling with the surrounding film. Our findings demonstrate that by reducing the laser spot size the influence of dipolar coupling on laser induced switching is becoming increasingly important.

17.
Ultramicroscopy ; 139: 1-4, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24509434

RESUMO

In situ electrical characterization of nanostructures inside a transmission electron microscope provides crucial insight into the mechanisms of functioning micro- and nano-electronic devices. For such in situ investigations specialized sample holders are necessary. A simple and affordable but flexible design is important, especially, when sample geometries change, a holder should be adaptable with minimum effort. Atomic resolution imaging is standard nowadays, so a sample holder must ensure this capability. A sample holder design for on-chip samples is presented that fulfils these requisites. On-chip sample devices have the advantage that they can be manufactured via standard fabrication routes.


Assuntos
Microscopia Eletrônica de Transmissão/instrumentação , Eletricidade , Nanoestruturas
18.
Methods Cell Biol ; 124: 275-303, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25287846

RESUMO

Live-cell correlative light and electron microscopy permits the visualization of ultrastructure details associated with dynamic biological processes. On the optical level, fluorescence microscopy can be further combined with functional studies of intracellular processes and manipulation of biological samples using laser light. However, the major challenge is to relocate intracellular compartments in three dimensions after the sample has undergone an extensive EM sample preparation process. Here, we describe a detailed protocol for live-cell CLEM that provides easy guidance for 3D relocalization. Based on the use of the novel polymer film TOPAS as direct imaging substrate, we provide a setup that uses highly visible toner particles for tracking the region of interest in 2D and fiducial markers for the 3D relocation of intracellular structures. An example is given where a single mitochondria is targeted by laser microirradiation in live-cell fluorescence microscopy. After relocating the same structure in 3D in serial EM sections, the changes to the mitochondrial ultrastructure are observed by TEM. The method is suitable for correlation of live-cell microscopy of cells and can be performed using any inverted optical microscope.


Assuntos
Análise de Célula Única/métodos , Células 3T3-L1 , Animais , Células HeLa , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Camundongos , Microscopia Eletrônica de Transmissão/instrumentação , Microscopia Eletrônica de Transmissão/métodos , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/métodos , Mitocôndrias/ultraestrutura , Polietilenos/química
19.
Microscopy (Oxf) ; 63(5): 345-55, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24891385

RESUMO

To obtain the correct tomographic reconstruction of micron-sized materials, the nonlinear intensity attenuation of bright-field transmission electron microscopy (BF-TEM) images was analyzed as a function of the sample thickness using a high-voltage electron microscope. The intensity attenuation was precisely measured relative to the projection thickness of carbon microcoils (CMCs) at acceleration voltages of 400-1000 kV using objective apertures (OAs) with radii of 2.1-28 nm(-1). The results show that the nonlinearity is strongly dependent on the OA size and the acceleration voltage. The influence of nonlinearity on tomographic reconstructions was also examined using a specially developed 360°-tilt sample holder. Sliced images of the reconstructed volumes indicated that an increase in the nonlinearity caused artificial fluctuations in the internal density of materials and inaccurate shapes of the objects in more significant cases. Conditions sufficient for reconstruction with the correct density have been estimated to be 0.67 of the minimum electron transmittance, and for reconstructions with correct shapes, 0.4. This information enables foreseeing the quality of the reconstruction from a single BF-TEM image prior to the tilt-series acquisition. As a result to demonstrate the appropriateness of these conditions, a CMC with a diameter of 3.7 µm was reconstructed successfully; i.e. not only the shape but also the internal density were correctly reproduced using electron tomography.

20.
Anal Chim Acta ; 811: 43-50, 2014 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-24456593

RESUMO

A surface flowing mode sample holder was designed as an alternative sampling strategy for direct analysis in real time mass spectrometry (DART-MS). With the sample holder, the on-line coupling of macroporous resin column chromatography with DART-MS was explored and the new system was employed to monitor the column chromatography elution process of Panax notoginseng. The effluent from macroporous resin column was first diluted and mixed with a derivatization reagent on-line, and the mixture was then directly transferred into the ionization region of DART-MS by the sample holder. Notoginsenosides were methylated and ionized in a metastable helium gas stream, and was introduced into MS for detection. The on-line system showed reasonable repeatability with a relative standard deviation of 12.3% for the peak area. Three notoginsenosides, i.e. notoginsenoside R1, ginsenoside Rb1 and ginsenoside Rg1, were simultaneously determined during the eluting process. The alteration of the chemical composition in the effluent was accurately identified in 9 min, agreeing well with the off-line analysis. The presented technique is more convenient compared to the traditional UPLC method. These results suggest that the surface flowing mode DART-MS has a good potential for the on-line process monitoring in the pharmaceutical industry.


Assuntos
Ginsenosídeos/análise , Espectrometria de Massas , Resinas Sintéticas/química , Cromatografia Líquida de Alta Pressão , Panax/química , Porosidade , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa