Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
1.
BMC Nephrol ; 25(1): 243, 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39075445

RESUMO

BACKGROUND: The prevalence of pre-frailty is notably high among maintenance hemodialysis (MHD) patients. Pre-frailty, an early and reversible condition between non-frailty and frailty, can lead to adverse outcomes such as increased unplanned hospital admissions and a higher risk of other chronic diseases. Early identification and intervention of pre-frailty in MHD patients are crucial. This study aimed to establish a simple and effective model for screening and identifying MHD patients at high risk of pre-frailty by using 50 kHz-Whole Body Phase Angle (PhA) measured by bioelectrical impedance analysis (BIA), hand grip strength (HGS), the Five-Times-Sit-to-Stand Test (FTSST), and laboratory parameters, with a specific focus on gender differences. METHODS: This prospective cross-sectional study was conducted from September to December 2023 at the Wenjiang Hemodialysis Center in the Department of Nephrology, West China Hospital, Sichuan University, Chengdu, China. A total of 244 MHD patients, including 130 males and 114 females, were enrolled, comprising 128 non-frail and 116 pre-frail individuals. Data were collected prospectively, including demographic information, physical measurements, and laboratory test results. All participants provided informed consent before enrollment. The FRAIL scale (FS) was used to assess pre-frailty in MHD patients. Grip strength was measured using an electronic grip strength tester, physical function was assessed using the Five-Times-Sit-to-Stand Test, and whole-body phase angle was measured using the InBody S10 device. RESULTS: A total of 244 MHD patients with a mean age of 53.75 ± 0.90 years were enrolled, including 130 males with a mean age of 54.12 ± 1.26 years and 114 females with a mean age of 53.32 ± 1.29 years. ROC curve analysis showed that in male patients, the AUC of PhA for predicting pre-frailty was 0.919, with a sensitivity of 94.5% and specificity of 91.3%, and a cutoff value of 6.05°; in female patients, the AUC of PhA was 0.870, with a sensitivity of 70.5% and specificity of 90.6%, and a cutoff value of 5.25°. The AUC of FTSST for screening pre-frailty in male patients was 0.827, with a sensitivity of 62.3% and specificity of 96.2%, and a cutoff value of 12.95 s; in female patients, the AUC of FTSST was 0.784, with a sensitivity of 67.3% and specificity of 84.0%, and a cutoff value of 12.95 s. Additionally, in male patients, the combination of PhA and FTSST resulted in an AUC of 0.930, with a sensitivity of 96.4% and specificity of 81.3%; in female patients, the AUC was 0.911, with a sensitivity of 78.7% and specificity of 92.5%. CONCLUSION: PhA measured by BIA, in combination with the Five-Times-Sit-to-Stand Test, serves as an effective screening tool and predictor of pre-frailty in MHD patients. The combination of PhA and FTSST shows enhanced diagnostic value in female patients, while PhA alone is sufficient for predicting pre-frailty in male patients. TRIAL REGISTRATION: Chinese Clinical Trial Registry (ChiCTR2100051111), registered on 2021-09-13.


Assuntos
Impedância Elétrica , Fragilidade , Força da Mão , Diálise Renal , Humanos , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Estudos Transversais , Fragilidade/diagnóstico , Fragilidade/fisiopatologia , Idoso
2.
Eur J Appl Physiol ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38900202

RESUMO

PURPOSE: The performance metric associated with the execution of the 1-min sit-to-stand (1STS) typically relies on the number repetitions completed in 1 min. This parameter presents certain limitations (e.g., ceiling effect, motivational factors) which can impede its interpretation. Introducing additional parameters, such as neuromuscular fatigability level, could enhance the informative value of the 1STS and facilitate its interpretation. This study aimed to assess (i) whether the 1STS induces fatigability and (ii) the reliability of the fatigability level. METHODS: Forty young, healthy, and active participants underwent the 1STS twice during the same session. Isolated sit-to-stand maneuvers were performed before, immediately, and 1 min after completing the 1STS. A mobile app was utilized to obtain time (STST), velocity (STSV), and muscle power (STSP) from these sit-to-stand maneuvers. The pre-post change in these parameters served as the fatigability marker. Reliability was assessed using the intra-class correlation coefficient (ICC) and the coefficient of variation (CV). RESULTS: The mean number of repetitions during the 1STS was 63 ± 9. Significant decline in performance was observed for STST (13 ± 8%), STSV (-11.2 ± 6%), and STSP (-5.2 ± 3%), with more than 74% of participants exhibiting a decline beyond the minimal detectable change. Excellent between-session reliability (ICC ≥ 0.9; CV ≤ 5.3) was observed for the mobile app variables. CONCLUSION: The 1STS induces significant levels of fatigability. The fatigability indicators derived from the mobile app demonstrated remarkable reliability. Utilizing this user-friendly interface for computing fatigability may empower professionals to acquire insightful complementary indicators from the 1STS.

3.
J Adv Nurs ; 80(9): 3825-3834, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38402452

RESUMO

OBJECTIVES: To develop an instrument to facilitate the risk assessment of falls in older outpatients. DESIGN: A quantitative methodological study using the cross-sectional data. METHODS: This study enrolled 1988 older participants who underwent comprehensive geriatric assessment (CGA) in an outpatient clinic from May 2020 to November 2022. The history of any falls (≥1 falls in a year) and recurrent falls (≥2 falls in a year) were investigated. Potential risk factors of falls were selected by stepwise logistic regression, and a screening tool was constructed based on nomogram. The tool performance was compared with two reference tools (Fried Frailty Phenotype; CGA with 10 items, CGA-10) by using receiver operating curves, sensitivity (Sen), specificity (Spe), and area under the curve (AUC). RESULTS: Age, unintentional weight loss, depression measured by the Patient Health Questionnaire-2, muscle strength measured by the five times sit-to-stand test, and stand balance measured by semi- and full-tandem standing were the most important risk factors for falls. A fall risk screening tool was constructed with the six measurements (FRST-6). FRST-6 showed the best AUC (Sen, Spe) of 0.75 (Sen = 0.72, Spe = 0.69) for recurrent falls and 0.65 (Sen = 0.74, Spe = 0.48) for any falls. FRST-6 was comparable to CGA-10 and outperformed FFP in performance. CONCLUSIONS: Age, depression, weight loss, gait, and balance were important risk factors of falls. The FRST-6 tool based on these factors showed acceptable performance in risk stratification. IMPACT: Performing a multifactorial assessment in primary care clinics is urgent for falls prevention. The FRST-6 provides a simple and practical way for falls risk screening. With this tool, healthcare professionals can efficiently identify patients at risk of falling and make appropriate recommendations in resource-limited settings. PATIENT OR PUBLIC CONTRIBUTION: No patient or public contribution was received, due to our study design.


Assuntos
Acidentes por Quedas , Avaliação Geriátrica , Humanos , Acidentes por Quedas/estatística & dados numéricos , Acidentes por Quedas/prevenção & controle , Idoso , Feminino , Masculino , Estudos Transversais , Idoso de 80 Anos ou mais , Avaliação Geriátrica/métodos , Medição de Risco/métodos , Fatores de Risco , Pacientes Ambulatoriais/estatística & dados numéricos , Inquéritos e Questionários
4.
Somatosens Mot Res ; 40(2): 72-77, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36524614

RESUMO

PURPOSE/AIM: Although Five Times-Sit-To-Stand test (FTSST) performance is known to be a valid and reliable method in people with chronic stroke, Parkinson's disease, and balance disorder, it has not been widely studied in patients with Multiple sclerosis (MS). The main aim of this study was to evaluate validity and reliability of the FTSST in patients with MS. METHODS: The first outcome measure of the study was the FTSST, which was conducted by two different researchers. Secondary outcome measures were Biodex Stability System (BSS), 10-meter walk test, time up go test (TUG), EDSS scoring, Fatigue Severity Scale (FSS), Barthel Index, Quadriceps Muscle strength test, Functional Reach test. Intraclass correlation coefficient (ICC) was used for the validity and reliability of the FTSST, which was made by two different researchers, and Pearson Correlation Analysis was used to determine its relationship with other measurements. RESULTS: Interrater and test-retest reliability for the FTSST were excellent (Intraclass correlation coefficients of 0.98 and 0.99, respectively). A statistically significant correlation was found between all secondary outcome measures and FTSST (p < 0.05). CONCLUSION: FTSST is considered to be a valid, reliable, easy, and rapid method for evaluating lower extremity muscle strength and balance in patients with MS.


Assuntos
Esclerose Múltipla , Acidente Vascular Cerebral , Humanos , Reprodutibilidade dos Testes , Força Muscular/fisiologia , Extremidade Inferior/fisiologia , Equilíbrio Postural/fisiologia
5.
Eur J Appl Physiol ; 123(7): 1543-1551, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36932213

RESUMO

PURPOSE: We aimed to (i) investigate differences in 1-minute sit-to-stand test (1MSTST) performance (i.e., the number of repetitions) between a standardised modality (i.e., starting from a conventional chair with 46 cm seat height) and an individualised modality (i.e., starting with a knee joint flexion angle of 90°), and to (ii) quantify the influence of tibia and femur length on 1MSTST performance. METHODS: Healthy participants were recruited for this randomised crossover study, performing each 1MSTST modality twice in a randomised order. The primary outcome was the number of repetitions in the 1MSTST. Secondary endpoints were the acute responses in peripheral oxygen saturation, heart rate, and leg fatigue and dyspnoea. Additionally, we investigated correlations of performance with knee extensor strength in both modalities. RESULTS: Thirty participants were recruited and completed the study. They achieved significantly less repetitions in the standardised 1MSTST compared to the individualised 1MSTST (B = - 12.1, 95% confidence interval [95% CI] = - 14.8/- 9.4, p < 0.001). We found a significant effect of femur length on 1MSTST performance (B = - 1.6, 95% CI = - 2.6/- 0.7, p = 0.01), tibia length showed significant interaction with the 1MSTST modality (B = 1.2, 95% CI = 0.2/2.2, p = 0.03). CONCLUSION: An individualisation of the 1MSTST starting position to 90° knee flexion angle leads to more repetitions compared to the traditional starting position. The higher repetition count is explained by controlling for differences in tibia length. We recommend individualisation of the 1MSTST, enabling more valid comparisons across populations and study samples. TRIAL REGISTRATION NUMBER: http://www. CLINICALTRIALS: gov , NCT04772417. TRIAL REGISTRATION DATE: February 26, 2021.


Assuntos
Articulação do Joelho , Extremidade Inferior , Humanos , Estudos Cross-Over , Extremidade Inferior/fisiologia , Articulação do Joelho/fisiologia
6.
J Clin Nurs ; 32(7-8): 1370-1380, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35332600

RESUMO

AIMS AND OBJECTIVES: The self-performance of a Five-Times-Sit-To-Stand (FTSTS)-test, without the usual supervision by a medical professional, provides valuable opportunities for clinical practice and research. This study aimed: (1) to determine the validity of the self-performed FTSTS test in comparison to a supervised reference test and (2) to determine the reliability of a self-performed FTSTS test by cancer survivors. BACKGROUND: Early detection of frailty in cancer survivors may enable prehabilitation interventions before surgery or intensive treatment, improving cancer outcomes. DESIGN: A repeated measures reliability and agreement study, with one week in between measures, was performed. METHODS: Cancer survivors (n = 151) performed two FTSTS tests themselves. One additional reference FTSTS test was supervised by a physical therapist. The intraclass correlation coefficient (ICC), structural error of measurement (SEM) and minimally important clinical difference (MID) were calculated comparing a self-performed FTSTS test to the reference test, and comparing two self-performed FTSTS tests. The Guidelines for Reporting Reliability and Agreement Studies (GRASS) have been used. RESULTS: Mean age of cancer survivors was 65.6 years (SD = 9.3), 54.6% were female, median time since diagnosis was 2 years [IQR = 1], and tumour type varied (e.g., breast cancer (31.8%), prostate cancer (17.2%), gastrointestinal cancer (11.9%) and haematological cancer (11.9%)). Validity of the self-performed FTSTS test at home was acceptable in comparison with the reference test (ICC = .74; SEM = 3.2; MID = 3.6) as was the reliability of the self-performed FTSTS test (ICC = .70; SEM = 2.2; MID = 3.8). CONCLUSIONS: The self-performed FTSTS test is a valid and reliable measure to assess lower body function and has potential to be used as objective (pre-)screening tool for frailty in cancer survivors. RELEVANCE TO CLINICAL PRACTICE: The self-performed FTSTS test at home may indicate the cancer survivors in need of prehabilitation in advance of surgery or intensive treatment. The feasibility, short amount of time needed and potential cost-effectiveness of the self-performed FTSTS test can make it a valuable contribution to personalised care and precision medicine.


Assuntos
Neoplasias da Mama , Sobreviventes de Câncer , Fragilidade , Masculino , Humanos , Feminino , Idoso , Detecção Precoce de Câncer , Reprodutibilidade dos Testes
7.
J Sport Rehabil ; 32(1): 46-52, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35894893

RESUMO

CONTEXT: More studies are needed to compare the effect of voluntary contraction, electrical stimulation, and electrical stimulation superimposed onto voluntary contraction in improving trained and untrained homolog muscle strength and lower-extremity endurance. DESIGN: Seventy-six healthy young adults (age = 20.41 [3.07] y, 61 females and 15 males) were included in the study. Subjects were randomly divided into 3 groups as voluntary isometric contraction (IC) group, Russian current (RC) group, and superimposed Russian current (SRC) group. METHODS: All training regimens were performed under physiotherapist supervision for a total of 18 sessions (3 times per week for 6 wk). In each session, 10 ICs were achieved with voluntary isometric exercise only, RC only, or RC superimposed onto ICs. Main outcome measures were trained and untrained quadriceps strength (maximal voluntary isometric contraction [MVIC]) and lower-extremity endurance (sit-to-stand test). RESULTS: After 6 weeks of training, all outcome measures improved in all groups (P < .05), except the untrained quadriceps MVIC score of RC group (P = .562). The trained quadriceps MVIC score (P < .001, η2 = .478), untrained quadriceps MVIC score (P = .011, η2 = .115), and sit-to-stand test score (P < .001, η2 = .357) differed significantly among the 3 groups; post hoc analysis revealed that the trained quadriceps MVIC score was higher in SRC and RC groups than in the IC group, untrained quadriceps MVIC score was higher in SRC group than in the RC group, and sit-to-stand test score was higher in SRC group than in the RC group and IC group. CONCLUSIONS: RC and RC superimposed onto IC are superior to IC in improving quadriceps muscle strength, and RC superimposed onto IC is superior to RC and IC in improving lower-extremity endurance. RC superimposed onto IC and voluntary IC created cross-education effect on untrained quadriceps.


Assuntos
Contração Isométrica , Músculo Quadríceps , Masculino , Adulto Jovem , Humanos , Feminino , Adulto , Músculo Quadríceps/fisiologia , Contração Isométrica/fisiologia , Extremidade Inferior , Força Muscular/fisiologia , Exercício Físico/fisiologia
8.
Respir Res ; 23(1): 266, 2022 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-36151560

RESUMO

BACKGROUND: Quadriceps muscle weakness and reduced exercise tolerance are prevalent and associated with a worse prognosis in patients with cystic fibrosis (CF). The one-minute sit-to-stand test (1STST) has been proposed to evaluate functional exercise capacity and quadriceps strength. RESEARCH QUESTION: The aim of the study was to verify the relationship between the 1STST and the maximal isometric voluntary contraction of the quadriceps (MVCQ) evaluated by the dynamometer in stable patients with CF and to evaluate the impact of intravenous (IV) antibiotherapy. METHODS: Dynamometer and 1STST were performed in stable patients with CF at a routine visit, the admission and the discharge of an IV antibiotherapy. Patients wore an activity monitor during 72 h during IV treatment. RESULTS AND SIGNIFICANCE: 51 stable patients with CF at a routine visit and 30 treated with IV antibiotherapy were recruited. In stable patients, the 1STST was reduced to a mean of 2101 nxkg (657-SD), representing a median of 79% (7; 142-min; max)) of the predicted values (%PV) as well as the MVCQ to 78.64 N-m (23.21; 170.34), representing 57%PV (26). The 1STST was correlated to MVCQ (r = 0.536; p < 0.0001) and lung function (r = 0.508; p = 0.0001). Over the IV antibiotherapy course, the 1STST improves significantly like lung function and body mass index while a positive trend for MVCQ was observed. The gain of 1STST was correlated to the change in MVCQ (r = 0.441; p = 0.02) and was significantly higher in hospitalized patients versus home therapy. The 1STST is a good alternative to the dynamometer to evaluate and assess muscular weakness for the routine visit and IV antibiotherapy.


Assuntos
Fibrose Cística , Debilidade Muscular , Fibrose Cística/diagnóstico , Fibrose Cística/tratamento farmacológico , Teste de Esforço/métodos , Tolerância ao Exercício/fisiologia , Humanos , Força Muscular/fisiologia , Debilidade Muscular/diagnóstico , Músculo Quadríceps
9.
Nephrol Dial Transplant ; 37(10): 1974-1981, 2022 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-35641182

RESUMO

BACKGROUND: The EXerCise Introduction To Enhance performance (EXCITE) trial (J Am Soc Nephrol 28: 1259-1268, 2017) in dialysis patients showed that a 6-month home walking exercise programme improves physical function and two dimensions of the Kidney Disease Quality of Life Short Form (KDQOLSF-SF™) questionnaire. Whether improvements in physical function achieved by exercise interventions are maintained in the long term has never been tested in the dialysis population. METHODS: In this post-trial study embedded in the EXCITE trial, we tested the response to the 6 min walking test (6MWT) and the 5-time Sit-To-Stand (5STS) tests and the KDQOLSF-SF™ from the 6th month (end of the trial) to the 36th month. RESULTS: Among the 227 patients of the EXCITE trial cohort, 162 underwent at least three out of four testing visits (baseline, 6, 18 and/or 36 months) contemplated by the study protocol and 89 during all four testing visits. In the primary analysis by the linear mixed model, the gain in walking distance achieved in the 6th month in the exercise group [between-arms difference: +36 m, 95% confidence interval (CI): 22-51, P < .001] was maintained at the 18th month (between-arms difference: +37 m, 95% CI: 19-57, P < .001) and reduced to 23 m (95% CI: -4 to 49 meters, P = .10) at the 36th month. Overall, the post-trial difference in walking distance trajectories between the two study arms was highly significant (P = .004). Furthermore, the walking distance changes at the 6th (r = 0.34, P = .018) and 18th month (r = 0.30, P = .043) were directly related to the number of structured exercise sessions completed during the trial (i.e. the first 6 month). No such effect was registered in the response to the 5STS or in quality of life as measured by the KDQOLSF-SF™. CONCLUSIONS: In dialysis patients, the benefits of a 6-month structured walking programme outlast the duration of the intervention and postpone the loss of walking performance which naturally occurs in this population, but does not affect the quality of life (QoL) and the response to the STS test.


Assuntos
Diálise Renal , Insuficiência Renal , Terapia por Exercício/métodos , Humanos , Qualidade de Vida , Caminhada
10.
Crit Care ; 26(1): 175, 2022 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-35698237

RESUMO

BACKGROUND: With ICU mortality rates decreasing, it is increasingly important to identify interventions to minimize functional impairments and improve outcomes for survivors. Simultaneously, we must identify robust patient-centered functional outcomes for our trials. Our objective was to investigate the clinimetric properties of a progression of three outcome measures, from strength to function. METHODS: Adults (≥ 18 years) enrolled in five international ICU rehabilitation studies. Participants required ICU admission were mechanically ventilated and previously independent. Outcomes included two components of the Physical Function in ICU Test-scored (PFIT-s): knee extensor strength and assistance required to move from sit to stand (STS); the 30-s STS (30 s STS) test was the third outcome. We analyzed survivors at ICU and hospital discharge. We report participant demographics, baseline characteristics, and outcome data using descriptive statistics. Floor effects represented ≥ 15% of participants with minimum score and ceiling effects ≥ 15% with maximum score. We calculated the overall group difference score (hospital discharge score minus ICU discharge) for participants with paired assessments. RESULTS: Of 451 participants, most were male (n = 278, 61.6%) with a median age between 60 and 66 years, a mean APACHE II score between 19 and 24, a median duration of mechanical ventilation between 4 and 8 days, ICU length of stay (LOS) between 7 and 11 days, and hospital LOS between 22 and 31 days. For knee extension, we observed a ceiling effect in 48.5% (160/330) of participants at ICU discharge and in 74.7% (115/154) at hospital discharge; the median [1st, 3rd quartile] PFIT-s difference score (n = 139) was 0 [0,1] (p < 0.05). For STS assistance, we observed a ceiling effect in 45.9% (150/327) at ICU discharge and in 77.5% (79/102) at hospital discharge; the median PFIT-s difference score (n = 87) was 1 [0, 2] (p < 0.05). For 30 s STS, we observed a floor effect in 15.0% (12/80) at ICU discharge but did not observe a floor or ceiling effect at hospital discharge. The median 30 s STS difference score (n = 54) was 3 [1, 6] (p < 0.05). CONCLUSION: Among three progressive outcome measures evaluated in this study, the 30 s STS test appears to have the most favorable clinimetric properties to assess function at ICU and hospital discharge in moderate to severely ill participants.


Assuntos
Cuidados Críticos , Unidades de Terapia Intensiva , Adulto , Idoso , Estado Terminal/reabilitação , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Assistência Centrada no Paciente , Modalidades de Fisioterapia , Respiração Artificial
11.
Support Care Cancer ; 30(10): 8251-8260, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35819522

RESUMO

PURPOSE: To determine whether the 30-s sit-to-stand (30STS) test can be a valid tool for estimating and stratifying peak oxygen uptake (VO2peak) and 6-min walking distance (6MWD) in women with breast cancer. METHODS: This cross-sectional study uses data from the ONCORE randomized controlled trial, including 120 women aged 18-70 years with early-stage breast cancer under treatment with anthracycline and/or anti-HER2 antibodies. Participant characteristics were collected at baseline and pooled data from functional assessment (30STS test, relative and absolute VO2peak, and 6MWD) were collected at baseline and post-intervention (comprehensive cardio-oncology rehabilitation program vs. usual care). Bivariate correlations and multivariate linear regression analyses were performed to study the relationship between functional test variables. RESULTS: The number of repetitions in the 30STS test showed (i) a moderate correlation with relative VO2peak (ml/kg/min) (r = 0.419; p < 0.001; n = 126), (ii) a weak correlation with absolute VO2peak (ml/min) (r = 0.241; p = 0.008; n = 120), and (iii) a moderate correlation with the 6MWD (r = 0.440; p < 0.001; n = 85). The ONCORE equations obtained from the multivariate regression models allowed the estimation of VO2peak and 6MWD (r2 = 0.390; r2 = 0.261, respectively) based on the 30STS test, and its stratification into tertiles (low, moderate, and high). CONCLUSION: The 30STS test was found to be a useful tool to estimate VO2peak and/or 6MWD in women with early-stage breast cancer. Its use may facilitate the assessment and stratification of functional capacity in this population for the implementation of therapeutic exercise programs if cardiopulmonary exercise testing (CPET) or 6MWT are not available. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03964142. Registered on 28 May 2019. Retrospectively registered. https://clinicaltrials.gov/ct2/show/NCT03964142.


Assuntos
Neoplasias da Mama , Tolerância ao Exercício , Antraciclinas/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Estudos Transversais , Teste de Esforço , Feminino , Humanos , Oxigênio , Consumo de Oxigênio , Caminhada
12.
Clin Rehabil ; 36(8): 1032-1041, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35473371

RESUMO

BACKGROUND: Wearing a surgical mask in hospitalized patients has become recommended during care, including rehabilitation, to mitigate coronavirus disease 2019 (COVID-19) transmission. However, the mask may increase dyspnoea and raise concerns in promoting rehabilitation activities in post-acute COVID-19 patients. OBJECTIVE: To evaluate the impact of the surgical mask on dyspnoea, exercise performance and cardiorespiratory response during a 1-min sit-to-stand test in hospitalized COVID-19 patients close to discharge. METHODS: COVID-19 patients whose hospital discharge has been planned the following day performed in randomized order two sit-to-stand tests with or without a surgical mask. Outcome measures were recorded before, at the end, and after two minutes of recovery of each test. Dyspnoea (modified Borg scale), cardiorespiratory parameters and sit-to-stand repetitions were measured. RESULTS: Twenty-eight patients aged 52 ± 10 years were recruited. Compared to unmasked condition, dyspnoea was significantly higher with the mask before and at the end of the sit-to-stand test (mean difference[95%CI]: 1.0 [0.6, 1.4] and 1.7 [0.8, 2.6], respectively). The difference was not significant after the recovery period. The mask had no impact on cardiorespiratory parameters nor the number of sit-to-stand repetitions. CONCLUSION: In post-acute COVID-19 patients near hospital discharge, the surgical mask increased dyspnoea at rest and during a submaximal exercise test but had no impact on cardiorespiratory response or exercise performance. Patients recovering from COVID-19 should be reassured that wearing a surgical facemask during physical or rehabilitation activities is safe. These data may also mitigate fears to refer these patients in rehabilitation centres where mask-wearing has become mandatory.


Assuntos
COVID-19 , Máscaras , COVID-19/prevenção & controle , Estudos Cross-Over , Dispneia/etiologia , Hospitais , Humanos , Alta do Paciente
13.
COPD ; 19(1): 125-132, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35385377

RESUMO

Timed-Up and Go (TUG) and 5-Times Sit-to-Stand (5STS) are frequently used in clinical practice for patients with chronic obstructive pulmonary disease (COPD). The aim of the study was to investigate the intra- and inter-rater reproducibility of the TUG and 5STS as both face-to-face and tele-assessment tests in patients with COPD. Forty-four patients with diagnosed COPD were included. Evaluations were carried out face-to-face and tele-assessment (synchronized and asynchronized). Inter-reliability between face-to-face and tele-assessment was excellent for TUG (ICC = 0.977) and 5STS (ICC = 0.970). Inter-reliability between two tele-raters was also excellent for TUG (ICC = 0.995) with the SEM = 0.04, SEM95% = 0.08, and SDC95% = 0.10 s, and 5STS (ICC = 0.990) with the SEM = 0.06, SEM95% = 0.12, and SDC95% = 0.18 s. Intra-rater reliability of the tele-assessment (synchronized) was excellent for TUG (ICC = 0.976) and 5STS (ICC = 0.964). The SEM, SEM95%, and SDC95% values were computed as 0.08, 0.16, and 0.22 s for TUG, and 0.11, 0.22, and 0.31 s for 5STS, respectively. The TUG and 5STS tests are reproducible tele-assessment measures in patients with COPD with excellent intra- and inter-rater reproducibility. The authors recommend these tests as practical assessment tools in patients with COPD at home for tele-health interventions. The reported SEM, SEM95%, and SDC95% values can be used as a minimum change that needs to be observed to be confident that the observed change is real and not, potentially, a product of measurement error.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Modalidades de Fisioterapia , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Reprodutibilidade dos Testes
14.
Sensors (Basel) ; 22(3)2022 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-35161478

RESUMO

Comprehensive measurements are needed in older populations to detect physical changes, initiate prompt interventions, and prevent functional decline. While established instruments such as the Timed Up and Go (TUG) and 5 Times Chair Rise Test (5CRT) require trained clinicians to assess corresponding functional parameters, the unsupervised screening system (USS), developed in a two-stage participatory design process, has since been introduced to community-dwelling older adults. In a previous article, we investigated the USS's measurement of the TUG and 5CRT in comparison to conventional stop-watch methods and found a high sensitivity with significant correlations and coefficients ranging from 0.73 to 0.89. This article reports insights into the design process and evaluates the usability of the USS interface. Our analysis showed high acceptance with qualitative and quantitative methods. From participant discussions, suggestions for improvement and functions for further development could be derived and discussed. The evaluated prototype offers a high potential for early detection of functional limitations in elderly people and should be tested with other target groups in other locations.


Assuntos
Programas de Rastreamento , Equilíbrio Postural , Idoso , Avaliação Geriátrica , Humanos , Modalidades de Fisioterapia , Estudos de Tempo e Movimento
15.
Chron Respir Dis ; 19: 14799731221119810, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36071021

RESUMO

OBJECTIVE: To determine if pre-frail Chronic obstructive pulmonary disease (COPD) patients with poor and non-poor performance in the five-repetition sit-to-stand test (5-STS) had a worse prognosis for hospitalization and mortality at 2 years and for mortality at 5 years than non-frail patients. METHODS: We prospectively included patients with stable COPD, between 40 and 80 years, from a hospital in Spain. Patients were classified according their performance on the 5-STS test and level of frailty. Timing, number of hospitalizations, length of stay, and timing and rate of mortality were outcome measures. Patients were followed for 2 years for exacerbations and for 5 years for mortality. Kaplan-Meier curves and univariate and multivariate Cox proportional-hazard analyses, ANOVA tests and univariate and multivariate linear and logistic regression models were used. RESULTS: Of the 125 patients included, 25.6% were pre-frail with poor performance, 57% pre-frail with non-poor performance, and 17.4% non-frail with non-poor performance. Pre-frail patients with poor performance had a higher number of hospitalizations (adjusted beta: 0.49; 95% CI: 0.01-0.96), mortality rates (odds ratio: 11.33; 95% CI: 1.15-110.81), and risk at 5 years (adjusted hazard ratio: 8.77; 95% CI: 1.02-75.51) than non-frail patients. Pre-frail patients with poor performance also had worse prognoses than non-frail patients with respect to length of hospital stays (increased by 4.16 days) and timing to first hospitalization (HR: 6.01) in unadjusted models, but not when adjusted. CONCLUSION: The COPD prognosis of pre-frail patients with respect to the number of exacerbations with hospitalization and the timing and rate of mortality is dependent of functional performance.


Assuntos
Fragilidade , Doença Pulmonar Obstrutiva Crônica , Hospitalização , Humanos , Desempenho Físico Funcional , Prognóstico
16.
J Surg Res ; 263: 130-139, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33652175

RESUMO

BACKGROUND: Traditional physical frailty (PF) screening tools are resource intensive and unsuitable for remote assessment. In this study, we used five times sit-to-stand test (5×STS) with wearable sensors to determine PF and three key frailty phenotypes (slowness, weakness, and exhaustion) objectively. MATERIALS AND METHODS: Older adults (n = 102, age: 76.54 ± 7.72 y, 72% women) performed 5×STS while wearing sensors attached to the trunk and bilateral thigh and shank. Duration of 5×STS was recorded using a stopwatch. Seventeen sensor-derived variables were analyzed to determine the ability of 5×STS to distinguish PF, slowness, weakness, and exhaustion. Binary logistic regression was used, and its area under curve was calculated. RESULTS: A strong correlation was observed between sensor-based and manually-recorded 5xSTS durations (r = 0.93, P < 0.0001). Sensor-derived variables indicators of slowness (5×STS duration, hip angular velocity range, and knee angular velocity range), weakness (hip power range and knee power range), and exhaustion (coefficient of variation (CV) of hip angular velocity range, CV of vertical velocity range, and CV of vertical power range) were different between the robust group and prefrail/frail group (P < 0.05) with medium to large effect sizes (Cohen's d = 0.50-1.09). The results suggested that sensor-derived variables enable identifying PF, slowness, weakness, and exhaustion with an area under curve of 0.861, 0.865, 0.720, and 0.723, respectively. CONCLUSIONS: Our study suggests that sensor-based 5×STS can provide digital biomarkers of PF, slowness, weakness, and exhaustion. The simplicity, ease of administration in front of a camera, and safety of 5xSTS may facilitate a remote assessment of PF, slowness, weakness, and exhaustion via telemedicine.


Assuntos
Fragilidade/diagnóstico , Avaliação Geriátrica/métodos , Exame Físico/instrumentação , Tecnologia de Sensoriamento Remoto/instrumentação , Dispositivos Eletrônicos Vestíveis , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Idoso Fragilizado , Humanos , Masculino , Exame Físico/métodos , Curva ROC , Tecnologia de Sensoriamento Remoto/métodos , Postura Sentada , Posição Ortostática , Fatores de Tempo
17.
Colorectal Dis ; 23(10): 2647-2658, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34346149

RESUMO

AIM: Postoperative functional outcomes following pelvic exenteration surgery for treatment of advanced or recurrent pelvic malignancies are poorly understood. The aim of this study was to determine the short-term functional outcomes following pelvic exenteration surgery using objective measures of physical function. METHOD: Patients undergoing pelvic exenteration surgery between January 2017 and May 2020 were recruited at a single quaternary referral hospital in Sydney, Australia. The primary measures were the 6-min walk test (6MWT) and the five times sit to stand (5STS) test. Data were collected at baseline (preoperatively), 10 days postoperatively and at discharge from hospital, and were analysed according to tumour type, extent of exenteration, sacrectomy, length of hospital stay, major nerve resection and postoperative complications. RESULTS: The cohort of patients that participated in functional assessments consisted of 135 patients, with a median age of 61 years. Pelvic exenteration patients had a reduced 6MWT distance preoperatively compared to the general population (P < 0.001). Following surgery, we observed a further decrease in 6MWT distance (P < 0.001) and an increase in time to complete 5STS (P < 0.001) at postoperative day 10 compared to baseline, with a slight improvement at discharge. There were no differences in 6MWT and 5STS outcomes between patients based on comparisons of surgical and oncological factors. CONCLUSION: Pelvic exenteration patients are functionally impaired in the preoperative period compared to the general population. Surgery causes a further reduction in physical function in the short term; however, functional outcomes are not impacted by tumour type, extent of exenteration, sacrectomy or nerve resection.


Assuntos
Exenteração Pélvica , Neoplasias Pélvicas , Humanos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/cirurgia , Neoplasias Pélvicas/cirurgia , Estudos Prospectivos , Estudos Retrospectivos
18.
Scand Cardiovasc J ; 55(3): 187-193, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33356620

RESUMO

Objectives. The One-minute Sit-To-Stand Test (STST) is a relatively novel physical performance test in the field of pulmonology. It measures the exercise tolerance of the patient. In this pilot study, we evaluated its predictive value for the postoperative course in cardiac surgery patients. Design. This was a prospective observational cohort study of patients undergoing elective aortic valve replacement. STST was applied in the patients, along with pulmonary function testing, a day prior to surgery, on postoperative day 7, and 3 months after surgery. A Short Form-36 health related quality of life survey (SF-36) was also included. The patients were divided into two groups according to the preoperative STST outcome: group A (≤20 repetitions, n = 12), and group B (>20 repetitions, n = 18). Results. We enrolled 30 patients in the study between May 2017 and May 2019. No complication were observed during the STST. The standard perioperative measures were identical for both groups. However, group A exhibited a significantly longer artificial ventilation time, as well as worse pulmonary function (VC, FVC, TLCO), on postoperative day 7. Concerning the SF-36, group A displayed a worse pre- and postoperative evaluation in both physical functioning and vitality. Conclusions. STST is a short and practical physical performance test that could enable a better prediction of the postoperative course after cardiac surgery. Patients with lower preoperative STST performance may require longer postoperative artificial ventilation, as they may present worse in some parameters of pulmonary functions and quality of life. However, these findings must be corroborated in larger studies.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Teste de Esforço , Cuidados Pré-Operatórios , Respiração Artificial , Humanos , Projetos Piloto , Estudos Prospectivos , Respiração Artificial/estatística & dados numéricos , Fatores de Tempo
19.
Sensors (Basel) ; 21(9)2021 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-34066716

RESUMO

Since conventional screening tools for assessing frailty phenotypes are resource intensive and unsuitable for routine application, efforts are underway to simplify and shorten the frailty screening protocol by using sensor-based technologies. This study explores whether machine learning combined with frailty modeling could determine the least sensor-derived features required to identify physical frailty and three key frailty phenotypes (slowness, weakness, and exhaustion). Older participants (n = 102, age = 76.54 ± 7.72 years) were fitted with five wearable sensors and completed a five times sit-to-stand test. Seventeen sensor-derived features were extracted and used for optimal feature selection based on a machine learning technique combined with frailty modeling. Mean of hip angular velocity range (indicator of slowness), mean of vertical power range (indicator of weakness), and coefficient of variation of vertical power range (indicator of exhaustion) were selected as the optimal features. A frailty model with the three optimal features had an area under the curve of 85.20%, a sensitivity of 82.70%, and a specificity of 71.09%. This study suggests that the three sensor-derived features could be used as digital biomarkers of physical frailty and phenotypes of slowness, weakness, and exhaustion. Our findings could facilitate future design of low-cost sensor-based technologies for remote physical frailty assessments via telemedicine.


Assuntos
Fragilidade , Idoso , Idoso de 80 Anos ou mais , Biomarcadores , Idoso Fragilizado , Fragilidade/diagnóstico , Avaliação Geriátrica , Humanos , Aprendizado de Máquina , Fenótipo
20.
Am J Kidney Dis ; 76(6): 815-825, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32512039

RESUMO

RATIONALE & OBJECTIVE: Frailty and poor physical function are associated with adverse kidney transplant outcomes, but how to incorporate this knowledge into clinical practice is uncertain. We studied the association between measured physical performance and clinical outcomes among patients on kidney transplant waitlists. STUDY DESIGN: Prospective observational cohort study. SETTING & PARTICIPANTS: We studied consecutive patients evaluated in our Transplant Readiness Assessment Clinic, a top-of-the-waitlist management program, from May 2017 through December 2018 (N=305). We incorporated physical performance testing, including the 6-minute walk test (6MWT) and the sit-to-stand (STS) test, into routine clinical assessments. EXPOSURES: 6MWT and STS test results. OUTCOMES: The primary outcome was time to adverse waitlist outcomes (removal from waitlist or death); secondary outcomes were time to transplantation and time to death. ANALYTICAL APPROACH: We used linear regression to examine the relationship between clinical characteristics and physical performance test results. We used subdistribution hazards models to examine the association between physical performance test results and outcomes. RESULTS: Median 6MWT and STS results were 393 (IQR, 305-455) m and 17 (IQR, 12-21) repetitions, respectively. Clinical characteristics and Estimated Post-Transplant Survival scores accounted for only 14% to 21% of the variance in 6MWT/STS results. Physical performance test results were associated with adverse waitlist outcomes (adjusted subdistribution hazard ratio [sHR] of 1.42 [95% CI, 1.30-1.56] per 50-m lower 6MWT test result and 1.53 [95% CI, 1.33-1.75] per 5-repetition lower STS test result) and with transplantation (adjusted sHR of 0.80 [95% CI, 0.72-0.88] per 50-m lower 6MWT test result and 0.80 [95% CI, 0.71-0.89] per 5-repetition lower STS test result). Addition of either STS or 6MWT to survival models containing clinical characteristics enhanced fit (likelihood ratio test P<0.001). LIMITATIONS: Single-center observational study. Other measures of global health status (eg, Fried Frailty Index or Short Physical Performance Battery) were not examined. CONCLUSIONS: Among waitlisted kidney transplant candidates with high kidney allocation scores, standardized and easily performed physical performance test results are associated with waitlist outcomes and contain information beyond what is currently routinely collected in clinical practice.


Assuntos
Falência Renal Crônica/diagnóstico , Transplante de Rim , Desempenho Físico Funcional , Medição de Risco/métodos , Transplantados , Listas de Espera , Adulto , Idoso , Feminino , Seguimentos , Humanos , Falência Renal Crônica/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa