Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
1.
Sensors (Basel) ; 24(6)2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38544164

RESUMO

Millimeter-wave (mmWave) radars attain high resolution without compromising privacy while being unaffected by environmental factors such as rain, dust, and fog. This study explores the challenges of using mmWave radars for the simultaneous detection of people and small animals, a critical concern in applications like indoor wireless energy transfer systems. This work proposes innovative methodologies for enhancing detection accuracy and overcoming the inherent difficulties posed by differences in target size and volume. In particular, we explore two distinct positioning scenarios that involve up to four mmWave radars in an indoor environment to detect and track both humans and small animals. We compare the outcomes achieved through the implementation of three distinct data-fusion methods. It was shown that using a single radar without the application of a tracking algorithm resulted in a sensitivity of 46.1%. However, this sensitivity significantly increased to 97.10% upon utilizing four radars using with the optimal fusion method and tracking. This improvement highlights the effectiveness of employing multiple radars together with data fusion techniques, significantly enhancing sensitivity and reliability in target detection.


Assuntos
Algoritmos , Privacidade , Animais , Humanos , Reprodutibilidade dos Testes , Transferência de Energia , Radar
2.
N Z Vet J ; : 1-6, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39143023

RESUMO

CASE HISTORY: A 4-month-old male Shih Tzu dog (Case 1) and an 11-month-old female Devon Rex cat (Case 2) were referred to specialist veterinary hospitals for evaluation of right thoracic lameness and growth abnormality in the distal aspect of the forelimb. CLINICAL FINDINGS: Non-weight-bearing lameness and decreased range of motion were noted in the affected limbs of both cases. Case 1 had a plantigrade stance, and a cleft separation between the first and second digits extending upwards to the distal third of the antebrachium. There was no pain on palpation, and the affected limb was shorter than the contralateral. Radiographic examination revealed cleft separation between metacarpal bones I and II, and carpal bone fusion (I, II, III), and the distal radius ended freely and was attached to the first metacarpal bone.Case 2 had a small cleft medial to metacarpal III. The limb was consistently held in abduction and had marked carpal varus. The limb had never been used for weight bearing. Radiographic examination showed agenesis of metacarpal bone II and separation of metacarpals I and III. The radius and ulna were separated and the radial head did not articulate normally at the elbow, leading to marked elbow incongruity. DIAGNOSIS: Ectrodactyly in both cases. TREATMENT AND OUTCOME: Amputation of the radius followed by ulnocarpal arthrodesis were performed in both cases. Follow-up evaluations up to 1 year (Case 1) and 10 weeks (Case 2) after surgery indicated satisfactory arthrodesis fusion, owner satisfaction, and a good clinical outcome. CLINICAL RELEVANCE: Ectrodactyly is a rare congenital deformity of the forelimb with a heterogeneous character, requiring an individualised treatment plan. These are the first cases reported in the literature of ectrodactyly in small animals that were treated successfully with ulnocarpal arthrodesis. This case series therefore provides evidence in support of this treatment option for this heterogeneous congenital deformity.

3.
J Anim Physiol Anim Nutr (Berl) ; 108(2): 541-556, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38091342

RESUMO

Ketogenic diets (KD) have been used in the treatment of epilepsy in humans for around a century and, more recently, they have been implanted for cancer patients, as well as in the treatment of obesity. This type of diet consists of high-fat levels, an adequate amount of protein and restricted carbohydrates, or high medium-chain triglycerides. Recently, the ketogenic diet has gained attention in veterinary medicine and studies were published evaluating the effects of KD in dogs with epilepsy. The objective of this review was to highlight recent studies about the application of KD in dogs and cats, to describe the neurobiochemical mechanisms through which KD improves epilepsy crisis, and their adverse effects. Studies were identified by a systematic review of literature available on PubMed, Embase, and Scopus. All cohort and case-control studies were included, and all articles were exported to Mendeley® citation manager, and duplicates were automatically removed. Seven articles and three conference abstracts conducted with dogs were included in the present study. There is evidence that the consumption of diets with medium-chain triglycerides increases the concentration of circulating ketone bodies and improves epilepsy signs, although these diets have higher carbohydrate and lower fat content when compared to the classic KD.


Assuntos
Doenças do Gato , Dieta Cetogênica , Doenças do Cão , Epilepsia , Humanos , Gatos , Cães , Animais , Dieta Cetogênica/efeitos adversos , Dieta Cetogênica/veterinária , Epilepsia/veterinária , Triglicerídeos/metabolismo
4.
Vet Radiol Ultrasound ; 64(3): 439-447, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36790748

RESUMO

Ultrasonography (US) and computed tomography (CT) are used to diagnose neoplastic and non-neoplastic focal renal lesions in dogs and cats; however, comparative studies between these two diagnostic tools are lacking. The aim of this retrospective, methods comparison study was to evaluate and compare the performance of US compared to CT in identifying at least one renal nodule in animals with confirmed focal renal lesions. Imaging studies of animals with uni- or bilateral renal nodules smaller than 3 cm that underwent both US and CT and that had a pathologically confirmed diagnosis were reviewed. Animals with renal cysts and infarcts were excluded. Recorded features for both modalities included the following: shape, size, number, localization, margins, renal profile. For CT only, recorded features also included attenuation (HU) and pattern of enhancement.  For US only, recorded features also included echogenicity, echostructure, and rate of visibility. Final diagnosis was obtained by cytology or histopathology. Using CT, lesions were identified in all 39 (100%) kidneys of 18 dogs and seven cats. Most lesions were multiple, cortical, well-defined, iso-attenuating (precontrast), hypo-attenuating, and moderately enhancing (postcontrast). Using US, lesions were identified in 29 of 39 (74%) kidneys. Overall, nine (31%) lesions were poorly visible; 10 (26%) kidneys appeared normal; in 17 (59%) organs, lesions' number was underestimated. Isoechoic, non-protruding lesions were difficult to identify by US. Ultrasonography underestimated renal lesions compared to CT in 59% of the kidneys (P = 0.001). Final diagnoses included metastatic disease (n = 16), infiltration by feline lymphoma (n = 4), primary neoplasia (n = 3), and non-neoplastic benign lesions (n = 2).


Assuntos
Doenças do Gato , Doenças do Cão , Gatos , Animais , Cães , Estudos Retrospectivos , Doenças do Gato/diagnóstico por imagem , Doenças do Gato/patologia , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/patologia , Rim/diagnóstico por imagem , Tomografia Computadorizada por Raios X/veterinária , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/veterinária , Ultrassonografia/métodos
5.
Am J Physiol Heart Circ Physiol ; 323(6): H1137-H1166, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36269644

RESUMO

Cardiac arrhythmias are a major cause of morbidity and mortality worldwide. Although recent advances in cell-based models, including human-induced pluripotent stem cell-derived cardiomyocytes (iPSC-CM), are contributing to our understanding of electrophysiology and arrhythmia mechanisms, preclinical animal studies of cardiovascular disease remain a mainstay. Over the past several decades, animal models of cardiovascular disease have advanced our understanding of pathological remodeling, arrhythmia mechanisms, and drug effects and have led to major improvements in pacing and defibrillation therapies. There exist a variety of methodological approaches for the assessment of cardiac electrophysiology and a plethora of parameters may be assessed with each approach. This guidelines article will provide an overview of the strengths and limitations of several common techniques used to assess electrophysiology and arrhythmia mechanisms at the whole animal, whole heart, and tissue level with a focus on small animal models. We also define key electrophysiological parameters that should be assessed, along with their physiological underpinnings, and the best methods with which to assess these parameters.


Assuntos
Doenças Cardiovasculares , Células-Tronco Pluripotentes Induzidas , Animais , Humanos , Técnicas Eletrofisiológicas Cardíacas , Arritmias Cardíacas/etiologia , Miócitos Cardíacos
6.
Small ; 18(17): e2200319, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35229457

RESUMO

Screening functional phenotypes in small animals is important for genetics and drug discovery. Multiphase microfluidics has great potential for enhancing throughput but has been hampered by inefficient animal encapsulation and limited control over the animal's environment in droplets. Here, a highly efficient single-animal encapsulation unit, a liquid exchanger system for controlling the droplet chemical environment dynamically, and an automation scheme for the programming and robust execution of complex protocols are demonstrated. By careful use of interfacial forces, the liquid exchanger unit allows for adding and removing chemicals from a droplet and, therefore, generating chemical gradients inaccessible in previous multiphase systems. Using Caenorhabditis elegans as an example, it is demonstrated that these advances can serve to analyze dynamic phenotyping, such as behavior and neuronal activity, perform forward genetic screen, and are scalable to manipulate animals of different sizes. This platform paves the way for large-scale screens of complex dynamic phenotypes in small animals.


Assuntos
Caenorhabditis elegans , Microfluídica , Animais , Microfluídica/métodos , Neurônios , Tensão Superficial
7.
Vet Radiol Ultrasound ; 62(1): 116-125, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33128837

RESUMO

The diagnosis of lung lobe torsion in dogs is usually based on radiological, endoscopic, and CT features. Few ultrasonographic descriptions have been published. The purpose of this multicenter, retrospective, and prospective observational study was to investigate the presence of a hypoechoic area forming a pulmonary band or line at the periphery of the twisted lobe on ultrasonography and assess its significance by comparing it to CT and histological findings. Fifteen dogs with lung lobe torsion confirmed surgically or postmortem were included. All had received ultrasonography and CT examinations; 13 had additional histopathological examination performed. In 14 cases, thoracic ultrasonography revealed a peripheral hypoechoic band, overlying areas of scattered, hyperreflecting interfaces in the affected lobe. On CT, central emphysema was surrounded by a peripheral, soft tissue attenuation band, affecting the periphery in 14 cases. No band was observed in one case, in which the lobe was entirely consolidated. Histological examination yielded a comparable peripheral band, consisting of a thickened visceral pleura with or without hemorrhagic necrosis of the underlying pulmonary parenchyma. This peripheral band may be related to the specific fractal organization of airways and vessels, which plays an important role in lung perfusion and ventilation and makes the lung periphery more prone to ischemia. Our findings suggest that the presence of a peripheral hypoechoic band, associated with central emphysema in a noncollapsed lung lobe on ultrasonography, is suggestive of compromised blood supply and air flow, and lung lobe torsion should therefore be suspected.


Assuntos
Cães/anormalidades , Pulmão/diagnóstico por imagem , Anormalidade Torcional/veterinária , Ultrassonografia/veterinária , Animais , Bélgica , Feminino , França , Pulmão/anormalidades , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Anormalidade Torcional/diagnóstico por imagem
8.
Acta Vet Hung ; 69(3): 216-222, 2021 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-34546965

RESUMO

Hospital infections are of great relevance in human and animal health, and fomites are important in the spread of pathogens in hospital units. The aim of this study was to investigate the frequency of enterobacteria in the operating room of a veterinary hospital, the potential cross-contamination of samples, and to characterise the susceptibility profile of the isolates to antimicrobials. Sixty-five samples were collected from five different surgical procedures. These samples came from the hands and cell phones of the surgical team and pet owners, operating tables, and patients. Species detection was performed through polymerase chain reaction, genetic diversity by pulsed-field gel electrophoresis (PFGE), and susceptibility to antimicrobials through an antibiogram. Escherichia coli and Proteus mirabilis isolates were obtained from eight samples, from the hands of the anaesthesiologist, the pet owner, and the surgeon; the surgeon's, the nurse's and the anaesthesiologist's cell phones, and two surgical tables. Furthermore, PFGE showed high genetic diversity among the isolates, which showed multidrug resistance. The identification of multidrug-resistant E. coli and P. mirabilis on cell phones of the surgical team is a major concern and, although no direct correlation was found, the isolation of these bacteria inside the clean area of the operating room shows the possibility of nosocomial transmission from cell phones to susceptible patients.


Assuntos
Telefone Celular , Enterobacteriaceae , Animais , Antibacterianos/farmacologia , Enterobacteriaceae/genética , Escherichia coli/genética , Hospitais Veterinários , Humanos , Testes de Sensibilidade Microbiana/veterinária
9.
Bull Exp Biol Med ; 168(3): 410-412, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31938909

RESUMO

We performed experimental evaluation of various positions (ear, paw, and tail) of the of dynamic light scattering sensor of near-infrared laser radiation (840 nm) using speckle interferometry in rats. Dynamic monitoring of the reactions to prolonged ultrasound exposure (7 days) showed that the base of the tail is most suitable for this purpose. Additionally, analysis of microcirculation parameters on the surface of skin autograft was performed. The method of analysis of hemodynamics in humans was adapted for animals.


Assuntos
Hemodinâmica/fisiologia , Interferometria/métodos , Lasers , Microcirculação/fisiologia , Animais , Masculino , Ratos
10.
J Med Virol ; 91(10): 1811-1817, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31209906

RESUMO

BACKGROUND: The safety and necessity of hepatitis B immunoglobulin (HBIG) in preventing the mother-to-child transmission of hepatitis B virus (HBV) are still controversial because of its unclear mechanism of action and the inconsistent injection programs used during gestation. OBJECTIVES: This study aimed to show the dynamic transportation and distribution of HBIG in the maternal body and to provide evidence for its clinical efficacy in preventing mother-to-child HBV transmission. STUDY DESIGN: Pregnant mice were injected with Cy7-labeled mouse anti-human monoclonal hepatitis B surface antibodies through the tail vein. In vivo imaging technology was used to observe the dynamic transportation and distribution of HBIG in the pregnant mice. RESULTS: HBIG fluorescence signals were higher in the uterus than in the liver, spleen, and kidneys. Fluorescence signals in the uterine region were obviously higher at the third trimester than at early and mid pregnancy. CONCLUSIONS: HBIG is gradually deposited in the mouse placenta during pregnancy, with the phenomenon being more significant in the third trimester.


Assuntos
Anticorpos Monoclonais , Antígenos de Superfície da Hepatite B/imunologia , Imunoglobulinas , Animais , Carbocianinas , Feminino , Troca Materno-Fetal , Camundongos , Camundongos Endogâmicos C57BL , Imagem Óptica , Gravidez
11.
BMC Vet Res ; 15(1): 264, 2019 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-31351494

RESUMO

BACKGROUND: Staphylococcus pseudintermedius is the leading cause of pyoderma in dogs and the frequent use of antimicrobial treatment is associated to the development of resistance to nearly all classes of antibiotics. Despite S. pseudintermedius significance, our understanding of the molecular mechanism of ß-lactam resistance and its genetic diversity remains limited. We aimed to: i) determine the phenotypic resistance profile of methicillin resistant Staphylococcus pseudintermedius (MRSP) isolated from infected dogs in three different veterinary hospitals in Buenos Aires, Argentina; ii) identify the SCCmec elements and resistance genes; and iii) analyze the clonal relationship between isolates and in regard of dominant lineages found in the world. RESULTS: In addition to the differential levels of ß-lactam resistance, MRSP isolates (n = 10) showed resistance to 5-6 families of antibiotics, and were therefore categorized as multidrug-resistant. All the isolates were variant of SCCmec V homologous to S. aureus; additional SCCmecFinder analysis classified five of the genomes as SCCmec type V (5C2&5) with mecA (encodes for PBP2a), mecRI and mecI and all the genes closely related to the reference SCCmec type V S. aureus TSGH17 strain. In the remaining five strains, mecA was present, although other genes associated with SCCmec V including mecR1 and mecI were missing. PBP2a was inducible in low level resistance strains (MRSP 8151), and constitutively expressed in MRSP 8150, suggesting different mecA regulatory mechanisms. MRSP isolates showed significant genetic diversity: eight PFGE clonal types and six multilocus-sequence typing (MLST) sequence types (STs) (339, 649, 919, 920, 921 and 922), including four new STs genetically distinct from STs reported in other geographic areas. Comparative genomics and phylogenetic analyses of the MRSP showed a correlation between the genetic content and the phenotypes, and established the genetic relationship between the isolates. CONCLUSIONS: MRSP could be a threat to animal health due to it concerning level of antimicrobial resistance. Our study highlights genetic and epidemiological aspects of multidrug-resistant MRSP strains from Argentina showing high degree of correlation between the resistance genes and the phenotype of the isolates and, furthermore, they appeared evolutionary closer to major worldwide reported ST68 and ST71.


Assuntos
Doenças do Cão/microbiologia , Resistência a Meticilina , Infecções Estafilocócicas/veterinária , Staphylococcus/genética , Staphylococcus/isolamento & purificação , Animais , Antibacterianos/farmacologia , Argentina/epidemiologia , Cães , Epidemiologia Molecular , Tipagem de Sequências Multilocus/veterinária , Filogenia , Infecções Estafilocócicas/epidemiologia , Infecções Estafilocócicas/microbiologia , Staphylococcus/efeitos dos fármacos
12.
Cardiovasc Ultrasound ; 17(1): 7, 2019 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-31010431

RESUMO

Echocardiography is the most commonly applied technique for non-invasive assessment of cardiac function in small animals. Manual tracing of endocardial borders is time consuming and varies with operator experience. Therefore, we aimed to evaluate a novel automated two-dimensional software algorithm (Auto2DE) for small animals and compare it to the standard use of manual 2D-echocardiographic assessment (2DE). We hypothesized that novel Auto2DE will provide rapid and robust data sets, which are in agreement with manually assessed data of animals.2DE and Auto2DE were carried out using a high-resolution imaging-system for small animals. First, validation cohorts of mouse and rat cine loops were used to compare Auto2DE against 2DE. These data were stratified for image quality by a blinded expert in small animal imaging. Second, we evaluated 2DE and Auto2DE in four mouse models and four rat models with different cardiac pathologies.Automated assessment of LV function by 2DE was faster than conventional 2DE analysis and independent of operator experience levels. The accuracy of Auto2DE-assessed data in healthy mice was dependent on cine loop quality, with excellent agreement between Auto2DE and 2DE in cine loops with adequate quality. Auto2DE allowed for valid detection of impaired cardiac function in animal models with pronounced cardiac phenotypes, but yielded poor performance in diabetic animal models independent of image quality.Auto2DE represents a novel automated analysis tool for rapid assessment of LV function, which is suitable for data acquisition in studies with good and very good echocardiographic image quality, but presents systematic problems in specific pathologies.


Assuntos
Algoritmos , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda/fisiologia , Animais , Modelos Animais de Doenças , Feminino , Ventrículos do Coração/fisiopatologia , Masculino , Camundongos , Ratos , Ratos Transgênicos , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia
13.
Vet Radiol Ultrasound ; 60(1): 56-64, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30475439

RESUMO

Contrast-enhanced ultrasonography (CEUS) is increasingly available for veterinary patients, however limited studies describe the use of this method for characterizing intrathoracic mass lesions. The aim of this prospective, observational study was to describe CEUS enhancement patterns for intrathoracic mass lesions in a sample of cats and dogs. Sixty patients (36 dogs, 24 cats) were included. Standardized CEUS examinations were performed for 41 pulmonary masses (68%) and 19 mediastinal masses (32%). Final diagnosis was based on cytology and/or histopathology. Absolute time to enhancement (TTE) values were recorded for the intrathoracic mass lesions and spleen. The spleen was used as a reference parenchymal organ to calculate relative TTE (rTTE) values. Absolute TTE of the spleen and intrathoracic mass lesions differed for dogs and cats (P = 0.001). The rTTE values significantly differed between lesions of neoplastic versus non-neoplastic origin (P = 0.004). The majority of neoplastic pulmonary masses were supplied by bronchial arteries (63%), while most nonneoplastic pulmonary masses were supplied by pulmonary arteries (78%). The sensitivity and specificity for detecting pulmonary neoplastic masses with rTTE were 63% and 78%, respectively. Enhancement patterns for mediastinal thymomas and lymphomas significantly differed (P = 0.002). Thymomas enhanced heterogeneously in a centripetal pattern (86%), whereas lymphomas typically enhanced uniformly in a centrifugal pattern (75%). Findings indicated that CEUS is a feasible method for characterizing intrathoracic mass lesions in dogs and cats, however, the diagnostic sensitivity for detecting neoplastic pulmonary masses was low.


Assuntos
Doenças do Gato/diagnóstico por imagem , Doenças do Cão/diagnóstico por imagem , Pneumopatias/veterinária , Doenças do Mediastino/veterinária , Ultrassonografia/veterinária , Animais , Gatos , Meios de Contraste , Cães , Feminino , Pneumopatias/diagnóstico por imagem , Masculino , Doenças do Mediastino/diagnóstico por imagem , Estudos Prospectivos
14.
Vet Radiol Ultrasound ; 60(3): 323-329, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30656772

RESUMO

Magnetic resonance imaging fat suppression techniques are commonly used for diagnosis of canine spinal disease, however, studies comparing different techniques are currently lacking. This retrospective, methods comparison study aimed to evaluate water excitation and STIR MRI pulse sequences for visualization of canine lumbar spinal nerve roots. For inclusion, all dogs had to have dorsal planar MRI studies of the lumbar spine using both sequences. Visual grading analysis was used for scoring the following five criteria: degree of fat suppression; nerve root visualization; subjective tissue contrast; presence of noise; and overall better image quality. Scores were independently recorded by three board-certified veterinary radiologists on two separate occasions, 3-6 weeks apart. A total of 90 dogs were sampled. A two-tailed t-test showed that there were significant differences in all scored parameters (P < 0.00001), with the exception of noise (P = 0.47343), and that the water excitation sequence scored higher in all cases excluding noise. A Gwets AC kappa for intraobserver and interobserver reliability showed "almost perfect" agreement for the nerve roots in both tests (intra: k = 0.88; inter: k = 0.90). Intraobserver agreement was "substantial" for the degree of fat suppression (k = 0.68), subjective tissue contrast (k = 0.75), and overall better image quality (k = 0.76) and it was "fair" for the noise (k = 0.46). Interobserver agreement was "moderate" for the degree of fat suppression (k = 0.53), subjective tissue contrast (k = 0.63), and overall better image quality (k = 0.66) and "slight" for noise (k = 0.25). These findings supported using the water excitation pulse sequence for fat-suppressed MRI of canine lumbar spinal nerve roots.


Assuntos
Cães , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética/veterinária , Raízes Nervosas Espinhais/diagnóstico por imagem , Animais , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
15.
Ir Vet J ; 72: 6, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31312432

RESUMO

BACKGROUND: T1w turbo spin echo (TSE) represents a fundamental sequence in magnetic resonance imaging (MRI) protocols investigating the brain. Recent human literature has reported T1w Fluid Attenuated Inversion Recovery's (FLAIR's), superiority to T1wTSE in relation to tissue contrast for grey-to-white matter (GM-WM) and lesion-to-WM, although conflicting results are reported concerning lesion detection.To the author's knowledge, T1wFLAIR has not been investigated in veterinary medicine. The aim of this prospective study was to determine quantitatively and qualitatively which sequence provides better overall better image quality both pre- and post-gadolinium. RESULTS: Twenty-eight animals underwent MRI of the brain with T1wTSE and T1wFLAIR sequences performed with equivalent mean acquisition times. Quantitative assessment of the sequences was undertaken using contrast-to-noise (CNR) and signal-to-noise (SNR) ratios from predefined locations. T1wFLAIR provided a better CNR compared to T1wTSE, while T1wTSE provided better SNR due to the higher noise levels of T1wFLAIR images. Qualitative assessment of the sequences was performed using Visual Grading Analysis Scoring (VGAS) for a number of criteria by three observers on two separate occasions. T1wFLAIR performed better for cerebrospinal fluid (CSF) suppression, white-to-grey matter (WM-GM) and white matter-to-CSF (WM-to-CSF) definition in both pre- and post-contrast images whereas the T1wTSE sequence was less affected by noise levels. The individual parameter for overall image quality found no significant difference between the two sequences. However, the composite VGAS favored T1wFLAIR as the preferred sequence. Although case numbers were insufficient for statistical analysis, comparison of the sequences indicates that lesion definition and margination was better in T1wFLAIR pre-contrast images, however post-contrast lesion detection was almost equivalent between sequences with slightly better margination in the T1wTSE sequence. CONCLUSIONS: T1wFLAIR provides better CNR with better WM-GM and WM-CSF definition both pre- and post-contrast compared to T1wTSE albeit with a higher degree of noise; this was confirmed both quantitatively and qualitatively. Our results also suggest that T1wFLAIR is better for lesion detection and margination pre-contrast administration and sequences are relatively equivocal post-gadolinium administration although further research is required to determine the benefit that inversion recovery sequences make when investigating brain lesions in small animal MRI.

16.
Appl Microbiol Biotechnol ; 102(5): 2117-2127, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29404644

RESUMO

Polyhydroxyalkanoate (PHA) is a family of microbial polyesters that is completely biodegradable and possesses the mechanical and thermal properties of some commonly used petrochemical-based plastics. Therefore, PHA is attractive as a biodegradable thermoplastic. It has always been a challenge to commercialize PHA due to the high cost involved in the biosynthesis of PHA via bacterial fermentation and the subsequent purification of the synthesized PHA from bacterial cells. Innovative enterprise by researchers from various disciplines over several decades successfully reduced the cost of PHA production through the efficient use of cheap and renewable feedstock, precisely controlled fermentation process, and customized bacterial strains. Despite the fact that PHA yields have been improved tremendously, the recovery and purification processes of PHA from bacterial cells remain exhaustive and require large amounts of water and high energy input besides some chemicals. In addition, the residual cell biomass ends up as waste that needs to be treated. We have found that some animals can readily feed on the dried bacterial cells that contain PHA granules. The digestive system of the animals is able to assimilate the bacterial cells but not the PHA granules which are excreted in the form of fecal pellets, thus resulting in partial recovery and purification of PHA. In this mini-review, we will discuss this new concept of biological recovery, the selection of the animal model for biological recovery, and the properties and possible applications of the biologically recovered PHA.


Assuntos
Ração Animal/microbiologia , Bactérias/metabolismo , Poli-Hidroxialcanoatos/metabolismo , Resíduos/análise , Ração Animal/análise , Ração Animal/economia , Animais , Bactérias/genética , Biodegradação Ambiental , Biomassa , Digestão , Fermentação , Resíduos/economia
17.
Cardiovasc Ultrasound ; 16(1): 10, 2018 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-29966517

RESUMO

BACKGROUND: The assessment of ventricular volumes using conventional echocardiography methods is limited with regards to the need of geometrical assumptions. In the present study, we aimed to evaluate a novel commercial system for three-dimensional echocardiography (3DE) in preclinical models by direct comparison with conventional 1D- and 2D-echocardiography (1DE; 2DE) and the gold-standard technique magnetic resonance imaging (MRI). Further, we provide a standard operating protocol for image acquisition and analysis with 3DE. METHODS: 3DE was carried out using a 30 MHz center frequency transducer coupled to a Vevo®3100 Imaging System. We evaluated under different experimental conditions: 1) in vitro phantom measurements served as controlled setting in which boundaries were clearly delineated; 2) a validation cohort composed of healthy C57BL/6 J mice and New Zealand Obese (NZO) mice was used in order to validate 3DE against cardiac MRI; 3) a standard mouse model of pressure overload induced-heart failure was investigated to estimate the value of 3DE. RESULTS: First, in vitro volumetry revealed good agreement between 3DE assessed volumes and the MRI-assessed volumes. Second, cardiac volume determination with 3DE showed smaller mean differences compared to cardiac MRI than conventional 1DE and 2DE. Third, 3DE was suitable to detect reduced ejection fractions in heart failure mice. Fourth, inter- and intra-observer variability of 3DE showed good to excellent agreement regarding absolute volumes in healthy mice, whereas agreement rates for the relative metrics ejection fraction and stroke volume demonstrated good to moderate observer variabilities. CONCLUSIONS: 3DE provides a novel method for accurate volumetry in small animals without the need for spatial assumptions, demonstrating a technique for an improved analysis of ventricular function. Further validation work and highly standardized image analyses are required to increase reproducibility of this approach.


Assuntos
Ecocardiografia Tridimensional , Insuficiência Cardíaca/diagnóstico por imagem , Volume Sistólico , Animais , Modelos Animais de Doenças , Ecocardiografia , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Obesos , Variações Dependentes do Observador , Reprodutibilidade dos Testes
18.
BMC Vet Res ; 13(1): 141, 2017 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-28545570

RESUMO

BACKGROUND: This study describes the feasibility of Contrast Enhanced Ultrasonography (CEUS) in the diagnostic work-up of non-cardiac thoracic disorders of small animals. The second aim is to assess the usefulness of CEUS as a direct guide for sample procedures. RESULTS: Forty animals, 28 dogs and 12 cats, were included in the study. Thoracic disorders included 23 pulmonary lesions [primary carcinoma (14), lymphoma (1), sarcoma (1), histiocytic sarcoma (1), abscess (1) and pneumonia (5)] and 17 mediastinal lesions [lymphoma (8), thymoma (3), mesothelioma (1), melanoma (1), carcinomatous lymphadenopathy (1), mixsosarcoma (1), lipoma (1), and abscess (1)]. The majority of neoplastic pulmonary lesions showed an inhomogeneous distribution of contrast medium, whereas inflammatory lesions had a homogenous distribution with typical pulmonary vessels ramification. The majority of mediastinal malignant lesions showed an inhomogeneous distribution pattern. The lung and mediastinal abscesses had peripheral enhancement of the wall with an avascular center. All cytological and biopsy samples obtained after CEUS were diagnostic. Quantitative analysis, performed in 19/23 pulmonary lesions, showed a statistically significant difference (P < 0.0001) between the arrival time of the malignant (7.27 s - range 4.46-13.52 s) and benign (4.52 s - range 2.87-6.06 s) pulmonary lesions. CONCLUSIONS: CEUS may be a useful tool for the evaluation of non-cardiac thoracic lesions. The contrast medium allows for the precise definition of lesion edges, the presence of necrotic areas, and the distribution of pulmonary vessels. Based on our preliminary results, the use of ultrasonographic contrast medium can be recommended for improving the diagnostic usefulness of cytology and biopsy sampling, because CEUS may help to define necrotic areas from viable tissue.


Assuntos
Doenças do Gato/diagnóstico por imagem , Doenças do Cão/diagnóstico por imagem , Pneumopatias/veterinária , Doenças do Mediastino/veterinária , Ultrassonografia/veterinária , Animais , Gatos , Meios de Contraste , Cães , Estudos de Viabilidade , Feminino , Pneumopatias/diagnóstico por imagem , Masculino , Doenças do Mediastino/diagnóstico por imagem , Estudos Prospectivos
19.
Vet Radiol Ultrasound ; 58(1): 18-22, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27790793

RESUMO

The CT "sentinel clot sign" has been defined as the highest attenuation hematoma adjacent to a bleeding organ in humans with hemoabdomen. The aims of this retrospective descriptive multicenter study were to describe CT findings in a sample of dogs with surgically or necropsy confirmed intra-abdominal bleeding and determine prevalence of the "sentinel clot sign" adjacent to the location of bleeding. Medical records between 2012 and 2014 were searched for dogs with hemoabdomen and in which the origin of the bleeding was confirmed either with surgery or necropsy. Retrieved CT images were reviewed for the presence and localization of the "sentinel clot sign," HU measurements of the "sentinel clot sign" and hemoabdomen, and presence of extravasation of contrast media within the abdominal cavity. Nineteen dogs were included. Three dogs were excluded due to the low amount of blood that did not allow the identification of a "sentinel clot sign." A "sentinel clot sign" was detected in the proximity of the confirmed bleeding organ in 14/16 (88%) of the patients. The mean HU of the "sentinel clot sign" was 56 (range: 43-70) while that of the hemoabdomen was 34 (range: 20-45). Active hemorrhage was identified as extravasation of contrast medium within the peritoneal cavity from the bleeding organ in three dogs. In conclusion, the CT "sentinel clot sign" may be helpful for identifying the source of bleeding in dogs with hemoabdomen.


Assuntos
Doenças do Cão/diagnóstico por imagem , Hematoma/veterinária , Tomografia Computadorizada por Raios X/veterinária , Animais , Doenças do Cão/epidemiologia , Cães , Feminino , Hematoma/diagnóstico por imagem , Hematoma/epidemiologia , Itália/epidemiologia , Masculino , Prevalência , Estudos Retrospectivos
20.
Magn Reson Med ; 73(3): 984-94, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24616047

RESUMO

PURPOSE: To develop an undersampled anatomical, three-dimensional (3-D) time-resolved magnetic resonance angiography (MRA) method for small animals based on time-of-flight (TOF) effect and radial sampling. METHODS: Mouse carotid arteries and Circle of Willis images were acquired on a 7T scanner with an electrocardiogram (ECG)-triggered sequence. Preliminary experiments were used to generate an approximately uniform distribution of radial projections with a first golden angle and to produce anatomical TOF images. A second golden angle ratio between consecutive projections of cine acquisitions was added to make it possible to use a temporal filter during reconstruction of time-resolved angiography. A decreasing number of projections were tested, and their impact on signal-to-noise ratio (SNR) and spatial resolution was assessed. RESULTS: In anatomical MRA, the undersampled radial approach efficiently allows fast acquisition of mouse angiogram in 3D (22 sec). It was also only slightly sensitive to motion and flow artifacts. The time-resolved sequence can be performed with only 2,500 projections per cine and a temporal resolution under 4 ms in a relatively short acquisition time (less than 5 min). CONCLUSION: This technique simultaneously provided high 3D isotropic spatial resolution and excellent temporal resolution with a good SNR level, allowing blood flow to be visualized in a restricted acquisition time.


Assuntos
Artérias Carótidas/anatomia & histologia , Círculo Arterial do Cérebro/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Algoritmos , Animais , Técnicas de Imagem de Sincronização Cardíaca/métodos , Interpretação Estatística de Dados , Camundongos , Camundongos Endogâmicos C57BL , Modelos Biológicos , Modelos Estatísticos , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa