Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Surg Radiol Anat ; 46(3): 271-283, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38374441

RESUMO

PURPOSE: Endoscopic third ventriculostomy (ETV) is a surgical procedure that can lead to complications and requires detailed preoperative planning. This study aimed to provide a more accurate understanding of the anatomy of the third ventricle and the location of important structures to improve the safety and success of ETV. METHODS: We measured the stereotactic coordinates of six points of interest relative to a predefined stereotactic reference point in 23 cadaver brain hemi-sections, 200 normal brain magnetic resonance imaging (MRI) scans, and 24 hydrocephalic brain MRI scans. The measurements were statistically analyzed, and comparisons were made. RESULTS: We found some statistically significant differences between genders in MRIs from healthy subjects. We also found statistically significant differences between MRIs from healthy subjects and both cadaver brains and MRIs with hydrocephalus, though their magnitude is very small and not clinically relevant. Some stereotactic points were more posteriorly and inferiorly located in cadaver brains, particularly the infundibular recess and the basilar artery. It was found that all stereotactic points studied were more posteriorly located in brains with hydrocephalus. CONCLUSION: The study describes periventricular structures in cadaver brains and MRI scans from healthy and hydrocephalic subjects, which can guide neurosurgeons in planning surgical approaches to the third ventricle. Overall, the study contributes to understanding ETV and provides insights for improving its safety and efficacy. The findings also support that practicing on cadaveric brains can still provide valuable information and is valid for study and training of neurosurgeons unfamiliar with the ETV technique.


Assuntos
Hidrocefalia , Neuroendoscopia , Terceiro Ventrículo , Humanos , Masculino , Feminino , Terceiro Ventrículo/diagnóstico por imagem , Terceiro Ventrículo/cirurgia , Neuroendoscopia/métodos , Encéfalo , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/cirurgia , Hidrocefalia/patologia , Ventriculostomia/métodos , Cadáver , Resultado do Tratamento , Estudos Retrospectivos
2.
Neuromodulation ; 22(4): 472-477, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30629330

RESUMO

INTRODUCTION: Clinical response to deep brain stimulation (DBS) strongly depends on the appropriate placement of the electrode in the targeted structure. Postoperative MRI is recognized as the gold standard to verify the DBS-electrode position in relation to the intended anatomical target. However, intraoperative computed tomography (iCT) might be a feasible alternative to MRI. MATERIALS AND METHODS: In this prospective noninferiority study, we compared iCT with postoperative MRI (24-72 hours after surgery) in 29 consecutive patients undergoing placement of 58 DBS electrodes. The primary outcome was defined as the difference in Euclidean distance between lead tip coordinates as determined on both imaging modalities, using the lead tip depicted on MRI as reference. Secondary outcomes were difference in radial error and depth, as well as difference in accuracy relative to target. RESULTS: The mean difference between the lead tips was 0.98 ± 0.49 mm (0.97 ± 0.47 mm for the left-sided electrodes and 1.00 ± 0.53 mm for the right-sided electrodes). The upper confidence interval (95% CI, 0.851 to 1.112) did not exceed the noninferiority margin established. The average radial error between lead tips was 0.74 ± 0.48 mm and the average depth error was determined to be 0.53 ± 0.40 mm. The linear Deming regression indicated a good agreement between both imaging modalities regarding accuracy relative to target. CONCLUSIONS: Intraoperative CT is noninferior to MRI for the verification of the DBS-electrode position. CT and MRI have their specific benefits, but both should be considered equally suitable for assessing accuracy.


Assuntos
Encéfalo/diagnóstico por imagem , Estimulação Encefálica Profunda/normas , Monitorização Neurofisiológica Intraoperatória/normas , Imageamento por Ressonância Magnética/normas , Tomografia Computadorizada por Raios X/normas , Adolescente , Adulto , Idoso , Encéfalo/cirurgia , Estimulação Encefálica Profunda/instrumentação , Estimulação Encefálica Profunda/métodos , Feminino , Humanos , Monitorização Neurofisiológica Intraoperatória/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
3.
World Neurosurg ; 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39209255

RESUMO

OBJECTIVE: To evaluate the accuracy of stereotactic coordinates to target the ansa lenticularis (AL) using 2 surgical planning methods, the conventional millimeter method (MM) and the normalized Tenths method (TM), assessed through individualized probabilistic tractography. METHODS: Stereotactic targeting of the AL was assessed in 2 groups: 16 patients with Parkinson's disease and 16 healthy controls from Group 1, and 39 Parkinson's disease patients from Group 2. Structural and diffusion magnetic resonance imaging probabilistic tractography identified the AL based on the Schaltenbrand-Wahren Atlas. The MM defined stereotactic coordinates in millimeters, while the TM refined the planning by dividing the intercommissural line (AC-PC) distance into 10 equal parts, normalizing the "X," "Y," and "Z" coordinates for each patient. We subsequently compared the percentage of structural connectivity (%conn) of the AL with predefined regions of interest (ROIs), including the frontopontine-corticothalamic tracts, globus pallidus internus-ventral oral anterior, and ventral oral posterior, and quantified the streamlines in 142 brain hemispheres using the MM and TM coordinates. RESULTS: Despite anatomical variations in intercommissural (AC-PC) line lengths between both groups (22.5 ± 2.09 mm and 24.4 ± 2.56 mm, respectively; P = 0.002), as well as differences in magnetic resonance imaging acquisition parameters, we found that the TM significantly enhanced streamline identification and %conn compared to the MM. These enhancements were noted across ROIs: frontopontine-corticothalamic and globus pallidus internus-ventral oral anterior in both hemispheres, and globus pallidus internus-ventral oral posterior in the left (P < 0.001) and right hemispheres (P = 0.03). CONCLUSIONS: TM surpasses MM in identifying the structural connectivity between the AL and predefined ROIs, underscoring the advantages of coordinate normalization. However, variations in AC-PC line lengths and Euclidean distances between methods could lead to inaccuracies in the coordinate settings, potentially affecting the precision of structural connectivity and the efficacy of therapeutic outcomes.

4.
Parkinsonism Relat Disord ; 64: 150-155, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30981663

RESUMO

BACKGROUND: Stimulation of the subthalamic area (STA) is an effective treatment in essential tremor patients, but limited by stimulation induced adverse effects. The aim of this study was to determine the spatial distribution of stimulus related tremor suppression, ataxia induction and paresthesia of the upper limb in the subthalamic area (STA) of essential tremor patients. METHODS: We recruited eight patients with essential tremor in a stable postoperative condition (>3 months after surgery). Stimulation-induced effects were assessed with suprathreshold stimulation. Tremor severity was assessed with the Fahn-Tolosa-Marin tremor rating scale (TRS) and cerebellar impairment was evaluated using the international cooperative ataxia rating scale (ICARS). Patients rated paresthesia intensity with a visual analog scale. Linear regression analysis was performed to associate stereotactic coordinates with tremor, ataxia and paresthesia. RESULTS: Suprathreshold stimulation significantly decreased tremor and elicited ataxia and paresthesia in all patients (P < 0.001). Tremor rating scale (TRS) total score was positively correlated with y-coordinates (r = 0.44, P < 0.05), i.e. anterior stimulation sites were more effective to suppress tremor. Concerning adverse effects, ataxia induction was positively correlated with z-coordinates almost reaching statistical significance (r = 0.50, P = 0.07), i.e. inferior stimulation sites elicit stronger ataxia. Furthermore, paresthesia was positively correlated with y-coordinates (r = 0.66; P < 0.01) and to a lesser degree with x-coordinates (r = 0.32; P = 0.08), i.e. posterior and lateral stimulation sites within the STA caused more paresthesia. CONCLUSION: Antero-dorso-medial stimulation site in the STA were associated with less tremor and adverse effects in our small single-center cohort of ET patients with thalamic DBS.


Assuntos
Mapeamento Encefálico , Estimulação Encefálica Profunda/efeitos adversos , Estimulação Encefálica Profunda/métodos , Tremor Essencial/terapia , Núcleo Subtalâmico/fisiologia , Idoso , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Parestesia/etiologia
5.
Front Neuroinform ; 5: 1, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21472085

RESUMO

While computer-aided planning of human neurosurgeries is becoming more and more common, animal researchers still largely rely on paper atlases for planning their approach before implanting recording chambers to perform invasive recordings of neural activity, which makes this planning process tedious and error-prone. Here we present SPLASh (Stereotactic PLAnning Software), an interactive software tool for the stereotactic planning of recording chamber placement and electrode trajectories. SPLASh has been developed for monkey cortical recordings and relies on a combination of structural MRIs and electronic brain atlases. Since SPLASh is based on the neuroanatomy software Caret, it should also be possible to use it for other parts of the brain or other species for which Caret atlases are available. The tool allows the user to interactively evaluate different possible placements of recording chambers and to simulate electrode trajectories.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa