Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Int Urogynecol J ; 34(5): 993-1000, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36598553

RESUMO

INTRODUCTION AND HYPOTHESIS: The aim of this study was to compare the surgical results and the complications of absorbable suture (AS) versus permanent suture (PS) in sacrocolpopexy (SCP). METHODS: We systematically searched PubMed, Embase, ClinicalTrials.gov, and the Cochrane Library Central Register of Controlled Trials for articles in which researchers compared AS with PS in SCP. The primary outcomes were the surgical success rate and suture-related complications (suture exposure/erosion, mesh erosion, and suture removal). All analyses were performed with Review Manager 5.3. RESULTS: Four articles involving 689 patients were ultimately included. Our findings demonstrated that AS had similar surgical success rates to those of PS (OR=1.34; 95% CI, 0.60-2.96) and no significant differences in failure rates were noted between the two groups (OR=0.75; 95% CI, 0.34-1.66). Subgroup analyses in patients with anatomical failure revealed no significant differences in recurrent posterior prolapse (OR=0.33; 95% CI, 0.05-2.10) or in recurrent apical (OR=0.64; 95% CI, 0.03-13.66) or anterior prolapse (OR=0.45; 95% CI, 0.13-1.57). However, the AS group were at a lower risk of suture exposure/erosion (OR=0.18; 95% CI, 0.06-0.58) and a lower suture removal rate (OR=0.14; 95% CI, 0.03-0.61) and retreatment (OR=0.36; 95% CI, 0.16-0.82), but the mesh erosion was not significantly different (OR=1.00; 95% CI, 0.49-2.08). CONCLUSIONS: The data showed that AS had a similar success rate, less exposure/erosion, and were less likely to be removed and require retreatment than PS, which supported the notion that AS is as effective as PS but safer.


Assuntos
Prolapso de Órgão Pélvico , Suturas , Feminino , Humanos , Procedimentos Cirúrgicos em Ginecologia/efeitos adversos , Procedimentos Cirúrgicos em Ginecologia/métodos , Prolapso de Órgão Pélvico/cirurgia , Prolapso , Telas Cirúrgicas/efeitos adversos , Suturas/efeitos adversos , Resultado do Tratamento
2.
Microb Pathog ; 172: 105796, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36155066

RESUMO

Staphylococcus pseudintermedius is the primary cause of pyoderma and surgical site infection (SSI) in dogs, and biofilm formation is the main reason for persistent SSI. The presence of biofilm in medical devices can directly impact treatment. Methicillin-resistant S. pseudintermedius (MRSP) emerged rapidly in companion animals, limiting treatment options. MRSP is a public health problem since zoonotic transmission can occur. The study seeks to evaluate biofilm formation capacity via Staphylococcus pseudintermedius collected from dogs affected by topical infections, in suture materials commonly used in companion animal surgery. We tested segments of four types of sutures. Biofilm production was measured by staining with safranin and colorimetric absorbance measurement. We calculated colony-forming units (CFUs) for each type of sutures and visualized biofilm via Scanning Electron Microscopy (SEM) images. The genes associated with biofilm formation (icaA and icaD) were identified using PCR. The colorimetric tests showed that the biofilm is most abundantly formed on the cotton sutures and polyglactin 910. The ability to form biofilm on polypropylene and nylon sutures has also been demonstrated, although at varying intensities. PCR revealed the presence of the two genes (icaA and icaD) in all the isolates. We used a positive control using a reference strain and negative control without bacteria for comparisons. Suture material allowing biofilm formation makes it difficult to prevent and treat surgical site infections. Therefore, it is important to know which suture thread is more susceptible to biofilm formation by bacteria to prevent possible secondary infections at surgical sites.


Assuntos
Doenças do Cão , Infecções Estafilocócicas , Cães , Animais , Nylons , Polipropilenos , Poliglactina 910 , Biofilmes , Suturas , Doenças do Cão/microbiologia , Infecções Estafilocócicas/veterinária , Infecções Estafilocócicas/microbiologia , Antibacterianos
3.
Int J Mol Sci ; 23(10)2022 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-35628199

RESUMO

Gastrointestinal anastomoses are an important source of postoperative complications. In particular, the ideal suturing material is still the subject of investigation. Therefore, this study aimed to evaluate a newly developed suturing material with elastic properties made from thermoplastic polyurethane (TPU); Polyvinylidene fluoride (PVDF) and TPU were tested in two different textures (round and a modified, "snowflake" structure) in 32 minipigs, with two anastomoses of the small intestine sutured 2 m apart. After 90 days, the anastomoses were evaluated for inflammation, the healing process, and foreign body reactions. A computer-assisted immunohistological analysis of staining for Ki67, CD68, smooth muscle actin (SMA), and Sirius red was performed using TissueFAXS. Additionally, the in vivo elastic properties of the material were assessed by measuring the suture tension in a rabbit model. Each suture was tested twice in three rabbits; No major surgical complications were observed and all anastomoses showed adequate wound healing. The Ki67+ count and SMA area differed between the groups (F (3, 66) = 5.884, p = 0.0013 and F (3, 56) = 6.880, p = 0.0005, respectively). In the TPU-snowflake material, the Ki67+ count was the lowest, while the SMA area provided the highest values. The CD68+ count and collagen I/III ratio did not differ between the groups (F (3, 69) = 2.646, p = 0.0558 and F (3, 54) = 0.496, p = 0.686, respectively). The suture tension measurements showed a significant reduction in suture tension loss for both the TPU threads; Suturing material made from TPU with elastic properties proved applicable for intestinal anastomoses in a porcine model. In addition, our results suggest a successful reduction in tissue incision and an overall suture tension homogenization.


Assuntos
Poliuretanos , Suturas , Anastomose Cirúrgica , Animais , Estudos de Viabilidade , Antígeno Ki-67 , Poliuretanos/química , Coelhos , Suínos , Porco Miniatura
4.
Int J Med Sci ; 18(2): 295-303, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33390798

RESUMO

Background: Implant loosening - either infectious or aseptic- is a still a major complication in the field of orthopaedic surgery. In both cases, a pro-inflammatory peri-prosthetic environment is generated by the immune system - either triggered by bacteria or by implant wear particles - which leads to osteoclast differentiation and osteolysis. Since infectious cases in particular often require multiple revision surgeries, we wondered whether commonly used surgical suture material may also activate the immune system and thus contribute to loss of bone substance by generation of osteoclasts. Methods: Tissue samples from patients suffering from infectious implant loosening were collected intraoperatively and presence of osteoclasts was evaluated by histopathology and immunohistochemistry. Further on, human monocytes were isolated from peripheral blood and stimulated with surgical suture material. Cell supernatant samples were collected and ELISA analysis for the pro-inflammatory cytokine IL-8 was performed. These experiments were additionally carried out on ivory slices to demonstrate functionality of osteoclasts. Whole blood samples were incubated with surgical suture material and up-regulation of activation-associated cell surface markers CD11b and CD66b on neutrophils was evaluated by flow cytofluorometry analysis. Results: We were able to demonstrate that multinucleated giant cells form in direct vicinity to surgical suture material. These cells stained positive for cathepsin K, which is a typical protease found in osteoclasts. By in vitro analysis, we were able to show that monocytes differentiated into osteoclasts when stimulated with surgical suture material. Resorption pits on ivory slices provided proof that the osteoclasts were functional. Release of IL-8 into cell supernatant was increased after stimulation with suture material and was further enhanced if minor amounts of bacterial lipoteichoic acid (LTA) were added. Neutrophils were also activated by surgical suture material and up-regulation of CD11b and CD66b could be seen. Conclusion: We were able to demonstrate that surgical suture material induces a pro-inflammatory response of immune cells which leads to osteoclast differentiation, in particular in combination with bacterial infection. In conclusion, surgical suture material -aside from bacteria and implant wear particles- is a contributing factor in implant loosening.


Assuntos
Procedimentos Ortopédicos/efeitos adversos , Osteólise/imunologia , Próteses e Implantes/efeitos adversos , Infecções Relacionadas à Prótese/imunologia , Suturas/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Diferenciação Celular/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Ortopédicos/instrumentação , Procedimentos Ortopédicos/métodos , Osteoclastos/patologia , Osteólise/prevenção & controle , Falha de Prótese , Infecções Relacionadas à Prótese/patologia
5.
Neurourol Urodyn ; 39(7): 1958-1965, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32658368

RESUMO

AIMS: The aims of this study were to compare surgical results and suture-related complications after uterosacral ligament suspension (USLS) with absorbable suture (AS) vs permanent suture (PS). METHODS: We systematically searched PubMed, Embase, clinicalTrial.gov, and Cochrane Library Central Register of Controlled Trials for articles that compared AS with PS for USLS. The primary outcomes were surgical success rate and suture-related complications (suture exposure/erosion and suture removal). Review Manager 5.3 (Cochrane Collaboration, Oxford, UK) was applied to conduct all analyses. RESULTS: Four articles involving 647 patients were eventually included. Our findings demonstrated that AS had a similar surgical success rates in comparison with PS (RR = 1.00; 95% CI, 0.94-1.06) and that no significant differences in anatomic failure rates were noted between two groups (RR = 1.10; 95% CI, 0.65-1.86). Subgroup analyses in anatomic failure revealed no statistical differences in apical prolapse ≥1/2 TVL (RR = 0.92; 95% CI, 0.48-1.75), recurrent prolapse beyond the hymen (RR = 1.18; 95% CI, 0.68-2.04), as well as in recurrent anterior, posterior or apical prolapse (P = .14, P = .08, P = .09, respectively). However, AS group indicated a lower risk in suture exposure/erosion (RR = 0.31; 95% CI, 0.15-0.63) and lower suture removal rate (RR = 0.35; 95% CI, 0.18-0.67). CONCLUSIONS: Due to similar surgical results, less suture exposure/erosion and less suture removal, the current data supported that AS is as effective as PS, but with a better safety profile.


Assuntos
Procedimentos Cirúrgicos em Ginecologia/métodos , Ligamentos/cirurgia , Suturas , Útero/cirurgia , Feminino , Humanos , Prolapso de Órgão Pélvico/cirurgia , Complicações Pós-Operatórias/epidemiologia , Suturas/efeitos adversos , Resultado do Tratamento , Prolapso Uterino/cirurgia
6.
BMC Vet Res ; 16(1): 87, 2020 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-32160877

RESUMO

BACKGROUND: Glycomer 631 and lactomer 9-1 are absorbable suture materials indicated for soft tissue approximation in non-infected wounds. Pigs are often used as surgical models in translational research; however, reports of tissue reactions to both suture materials in pigs are limited. The aim of this study was to assess clinical and histologic responses of skin incisions closed with a subcuticular technique using glycomer 631 and lactomer 9-1 in pigs. RESULTS: Skin incisions on 17 pigs were closed with glycomer 631 and lactomer 9-1, and a clinical reactive score (CRS) including erythema, swelling, discharge and dehiscence was calculated on postoperative days 7 and 14. Subcuticular tissue reaction was assessed histologically on postoperative day 14 (the presence of extravascular neutrophils, macrophages, multinucleated giant cells, lymphocytes, fibroblasts, bacterial colonies and the overall severity of the inflammatory response to the suture material), and the cumulative score of the variables was calculated as an aggregate tissue irritation score (ATIS). Tissue samples were examined for suture extrusion and evaluated microbiologically. The clinical reactive score did not differ between the suture materials. Only one ATIS variable, namely the overall severity of the inflammatory response, was lower (p = 0.029) when glycomer 631 was used. Suture extrusion was found in 10/17 of the incisions closed by glycomer 631 and in 7/13 of the incisions closed by lactomer 9-1. Trueperella pyogenes was isolated from the skin and from the area of tissue reaction in six pigs. CONCLUSIONS: No difference in CRS between the suture materials was observed, and thus both materials may be used for the subcuticular technique in pigs. Glycomer 631 induced less tissue reaction only in terms of the overall severity of the inflammatory response. Suture extrusion was observed in more than 50% of incisions regardless of the suture material, possibly due to a large amount of suture material in the wound. Trueperella pyogenes was the only pathogen isolated from the tissue surrounding the suture material.


Assuntos
Dioxanos , Polímeros , Técnicas de Sutura/veterinária , Suturas , Suínos/cirurgia , Animais , Procedimentos Cirúrgicos Dermatológicos/instrumentação , Procedimentos Cirúrgicos Dermatológicos/veterinária , Feminino , Masculino
7.
Int Urogynecol J ; 31(10): 2011-2018, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32638062

RESUMO

INTRODUCTION AND HYPOTHESIS: The wide variety of suture material used in colporrhaphy shows a lack of consensus on the optimal choice. The evidence guiding the choice of suture material is scant. The aim of this study was to investigate the effects of rapid versus slowly absorbable suture on risk of recurrence after native tissue anterior colporrhaphy. METHODS: This longitudinal cohort study was performed secondary to a previously published study on pelvic organ prolapse recurrence after the Manchester-Fothergill procedure versus vaginal hysterectomy. Data were collected from four Danish databases and corresponding electronic medical records. In this study, women having had anterior colporrhaphy performed were included. Suture materials were divided in three groups: rapid absorbable multifilament suture (RAMuS), rapid absorbable monofilament suture (RAMoS) and slowly absorbable monofilament suture (SAMoS). The main outcome was recurrence of prolapse in the anterior compartment. RESULTS: A total of 462 women were included in this study. No significant difference in recurrence was found among the three suture groups. However, a non-significant tendency towards a higher risk of recurrence in the RAMoS group [HR 2.14 (0.75-6.10) p = 0.16] compared to the RAMuS group was observed. CONCLUSION: In this study, the use of rapid absorbable multifilament suture compared to slowly absorbable monofilament suture does not seem to lead to a higher risk of recurrence after anterior colporrhaphy.


Assuntos
Procedimentos Cirúrgicos em Ginecologia , Prolapso de Órgão Pélvico , Feminino , Humanos , Estudos Longitudinais , Recidiva Local de Neoplasia , Prolapso de Órgão Pélvico/cirurgia , Recidiva , Telas Cirúrgicas , Suturas/efeitos adversos , Resultado do Tratamento
8.
Khirurgiia (Mosk) ; (3): 29-34, 2020.
Artigo em Russo | MEDLINE | ID: mdl-32271734

RESUMO

OBJECTIVE: Experimental assessment of the effect of modified and unmodified surgical suture material on abdominal adhesive process. MATERIAL AND METHODS: The study was performed on male rats of the Wistar subpopulation. There were 5 animals in each group. In all animals, midline abdominal incision was followed by suturing the parietal peritoneum with modified and unmodified suture material. All animals were euthanized with carbon dioxide vapors in 14 days after surgery. Macro- and microscopic assessment of severity of abdominal adhesive process was carried out. Two types of preparation of excised complexes 'peritoneum-suture material-adhesion' were applied for histological examination: paraffin sections and embedding in epoxy resin. Specimens were stained by Van Gieson and with methylene blue solution. Histological specimens were examined using Axio Imager A1 light microscope (Zeiss, Germany). RESULTS: Polypropylene filaments result extensive adhesions occupying about 75% of the area. Adhesions have a dense structure with signs of vascularization. Modification of suture material with solution of polyhydroxybutyrate/hydroxyvalerate and heparin reduce severity of adhesions. The use of modified suture material was followed by adhesions with more loose structure, no signs of vascularization. Adhesions occupied less than 25% of the area. Histological examination of excised complexes 'peritoneum-suture material-adhesion' revealed accumulation of inflammatory cells around the unmodified suture material, while there were no signs of tissue inflammatory process around the modified sutures. CONCLUSION: Application of polyhydroxybutyrate/hydroxyvalerate and heparin on the surface of surgical sutures is an effective method for prevention of abdominal adhesions.


Assuntos
Materiais Biocompatíveis/efeitos adversos , Heparina/administração & dosagem , Poliésteres/administração & dosagem , Polipropilenos/efeitos adversos , Suturas/efeitos adversos , Aderências Teciduais/prevenção & controle , Animais , Materiais Biocompatíveis/administração & dosagem , Materiais Revestidos Biocompatíveis/administração & dosagem , Materiais Revestidos Biocompatíveis/efeitos adversos , Modelos Animais de Doenças , Heparina/efeitos adversos , Masculino , Neovascularização Patológica/etiologia , Neovascularização Patológica/prevenção & controle , Peritônio/irrigação sanguínea , Peritônio/patologia , Peritônio/cirurgia , Poliésteres/efeitos adversos , Polipropilenos/administração & dosagem , Ratos , Ratos Wistar , Aderências Teciduais/etiologia , Aderências Teciduais/patologia
9.
Khirurgiia (Mosk) ; (10): 75-81, 2019.
Artigo em Russo | MEDLINE | ID: mdl-31626243

RESUMO

Postoperative complications in vascular surgery may be partly provoked by suture material. Analysis of the mechanisms of these complications may be useful for their prevention. Mechanisms of suture-induced thrombosis and neointimal hyperplasia, possible strategies for prevention of postoperative complications including those allowing drug deliveries directly to the vascular anastomosis area are discussed in the article. According to the literature data, heparin is the most optimal drug for modifying suture material and prevention of thrombosis and neointimal hyperplasia. Heparin delivery to the vascular anastomosis site will reduce the risk of thrombosis by inhibiting the activity of thrombin. Complex of heparin and antithrombin III increases inhibitory effect of antithrombin against thrombin. In addition, heparin is able to reduce proliferation of vascular smooth muscle cells through inhibition of the synthesis of extracellular matrix proteases involved in migration and proliferation of cells. Thus, heparin delivery to the vascular injury site may be used to prevent thrombosis and myoproliferative response. Moreover, this strategy prevents complications associated with systemic administration of anticoagulants.


Assuntos
Suturas/efeitos adversos , Trombose/prevenção & controle , Doenças Vasculares/prevenção & controle , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Anticoagulantes/administração & dosagem , Heparina/administração & dosagem , Humanos , Hiperplasia/etiologia , Hiperplasia/patologia , Hiperplasia/prevenção & controle , Neointima/patologia , Trombose/etiologia , Doenças Vasculares/etiologia
10.
Acta Neurochir (Wien) ; 160(3): 497-503, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29189910

RESUMO

BACKGROUND: Wound healing impairment is a serious problem in surgical disciplines which may be associated with chronic morbidity, increased cost and patient discomfort. Here we aimed to investigate the relevance of bacterial colonisation on suture material using polymerase chain reaction (PCR) to detect and taxonomically classify bacterial DNA in patients with and without wound healing problems after routine neurosurgical procedures. METHODS: Repeat surgery was performed in 25 patients with wound healing impairment and in 38 patients with well-healed wounds. To determine the presence of bacteria, a 16S rDNA-based PCR detection method was applied. Fragments of 500 bp were amplified using universal primers which target hypervariable regions within the bacterial 16S rRNA gene. Amplicons were separated from each other by single-strand conformation polymorphism (SSCP) analysis, and finally classified using Sanger sequencing. RESULTS: PCR/SSCP detected DNA of various bacteria species on suture material in 10/38 patients with well-healed wounds and in 12/25 patients with wound healing impairment including Staphylococcus aureus, Staphylococcus epidermidis, Propionibacterium acnes and Escherichia coli. Microbiological cultures showed bacterial growth in almost all patients with wound healing impairment and positive results in PCR/SSCP (10/12), while this was the case in only one patient with a well-healed wound (1/10). CONCLUSIONS: Colonisation of suture material with bacteria occurs in a relevant portion of patients with and without wound healing impairment after routine neurosurgical procedures. Suture material may provide a nidus for bacteria and subsequent biofilm formation. Most likely, however, such colonisation of sutures is not a general primer for subsequent wound infection.


Assuntos
Bactérias , Procedimentos Neurocirúrgicos/efeitos adversos , Infecção da Ferida Cirúrgica/microbiologia , Suturas/microbiologia , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , DNA Bacteriano/genética , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Polimorfismo Conformacional de Fita Simples , Estudos Prospectivos , RNA Ribossômico 16S/genética , Cicatrização , Adulto Jovem
11.
Pancreatology ; 16(1): 138-41, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26712241

RESUMO

PURPOSE: Pancreatic fistula represents the most important complication in terms of clinical management and costs after pancreaticoduodenectomy. A lot of studies have investigated several techniques in order to reduce pancreatic fistula, but data on the effect of sutures material on pancreatic fistula are not available. The analysis investigated the role of suture material in influencing pancreatic fistula rate and severity. METHODS: Results from 130 consecutive pancreaticoduodenectomy with pancreaticojejunostomy performed between March 2013 and September 2014 were prospectively collected and analyzed. In 65 cases pancreaticojejunostomy was performed with absorbable sutures, in the other 65 cases using non-absorbable sutures (polyester, silk and polybutester). RESULTS: Pancreaticojejunostomy with non-absorbable sutures had the same incidence of pancreatic fistula, but less severe and with less episodes of post-operative bleeding if compared with absorbable sutures. A sub-analysis was carried out comparing polydioxanone with polyester: the latter was associated with a lower pancreatic fistula rate (11.9% vs. 31.7%; p = 0,01) and less severe pancreatic anastomosis dehiscence (grade C - 0% vs. 30%; p = 0.05). Univariate and multivariate analysis confirmed that hard pancreatic texture, pancreatic ductal adenocarcinoma at final histology and the use of polyester for pancreaticojejunostomy were associated with a lower pancreatic fistula rate (p < 0.05). CONCLUSION: Further studies are needed to investigate the effects of pancreatic juice and bile on different sutures and pancreatic tissue response to different materials. However, pancreaticojejunostomy performed with polyester sutures is safe and feasible and is associated to a lower incidence of pancreatic fistula with less severe clinical impact.


Assuntos
Fístula Pancreática/etiologia , Pancreaticoduodenectomia/efeitos adversos , Pancreaticojejunostomia/efeitos adversos , Complicações Pós-Operatórias/etiologia , Suturas , Adulto , Idoso , Idoso de 80 Anos ou mais , Anastomose Cirúrgica/métodos , Feminino , Humanos , Jejuno/cirurgia , Masculino , Pessoa de Meia-Idade , Pâncreas/cirurgia , Polidioxanona , Poliésteres , Estudos Retrospectivos , Seda , Suturas/classificação
12.
Int Urogynecol J ; 27(9): 1357-65, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26935306

RESUMO

INTRODUCTION AND HYPOTHESIS: The optimal suture material in traditional prolapse surgery is still controversial. Our aim was to investigate the effect of using sutures with rapid (RA) or slow (SA) absorption, on symptomatic recurrence after anterior and posterior colporrhaphy. METHODS: A population-based longitudinal cohort study with data from the Swedish National Quality Register for Gynecological Surgery. A total of 1,107 women who underwent primary anterior colporrhaphy and 577 women who underwent primary posterior colporrhaphy between September 2012 and September 2013 were included. Two groups in each cohort were created based on which suture material was used. Pre- and postoperative prolapse-related symptoms and patient satisfaction were assessed. RESULTS: We found a significantly lower rate of symptomatic recurrence 1 year after anterior colporrhaphy in the SA suture group compared with the RA suture group, 50 out of 230 (22 %) vs 152 out of 501 (30 %), odds ratio 1.6 (CI 1.1-2.3; p = 0.01). The SA group also had a significantly higher patient satisfaction rate, 83 % vs 75 %, odds ratio 1.6 (CI 1.04-2.4), (p = 0.03). Urgency improved significantly more in the RA suture group (p < 0.001). In the posterior colporrhaphy cohort there was no significant difference between the suture materials. CONCLUSIONS: This study indicates that the use of slowly absorbable sutures decreases the odds of having a symptomatic recurrence after an anterior colporrhaphy compared with the use of rapidly absorbable sutures. However, the use of RA sutures may result in less urgency 1 year postoperatively. In posterior colporrhaphy the choice of suture material does not affect postoperative symptoms.


Assuntos
Procedimentos Cirúrgicos em Ginecologia/métodos , Prolapso de Órgão Pélvico/cirurgia , Suturas , Vagina/cirurgia , Absorção Fisico-Química , Idoso , Feminino , Humanos , Estudos Longitudinais , Pessoa de Meia-Idade , Satisfação do Paciente , Período Pós-Operatório , Recidiva , Técnicas de Sutura , Suécia , Resultado do Tratamento
13.
Int J Colorectal Dis ; 30(11): 1571-80, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26260480

RESUMO

PURPOSE: Intestinal anastomosis is a fundamental procedure in general surgery and required to restore intestinal continuity following resection. The aim of this study was to evaluate whether a gentamicin-coated polyvinylidene fluoride (PVDF) suture material has beneficial effect on anastomotic healing. METHODS: Ninety Sprague-Dawley rats were divided into three groups: a PVDF-suture group, a gentamicin-coated PVDF (GPVDF)-suture group and a control group using Maxon® (polyglycolid-co-trimethylene carbonate). For each animal, a colonic anastomosis was performed. Ten animals from each group were sacrificed on postoperative days 3, 5, and 14. Measurements of anastomotic bursting pressure were performed on days 3 and 5. At each time, collagen type I/III ratio, MMP 2 and MMP-9 expression and the proliferation index (Ki67) were analyzed. RESULTS: In total, 90 animals underwent surgery without postoperative complications. Bursting strength in the GPVDF group was significantly elevated on day 5. Immunohistochemistry showed significant increase of the collagen type I/III ratio for PVDF and GPVDF on days 3 and 5. MMP2 was significantly increased for PVDF on days 3 and 5 and for GPVDF on day 5. The analysis of MMP9 revealed significant increase compared to control on day 3 and 5 (GPVDF) as well as on day 5 (PVDF). Staining for Ki67 revealed a significant elevation on postoperative day 3 for the PVDF and the GPVDF group. CONCLUSIONS: The present data shows the feasibility of PVDF as suture material for colonic anastomosis and confirms the ability of gentamicin to increase the stability of colonic anastomosis when used as coating material.


Assuntos
Gentamicinas , Intestinos/cirurgia , Polivinil , Inibidores da Síntese de Proteínas , Suturas , Cicatrização/efeitos dos fármacos , Anastomose Cirúrgica , Animais , Colágeno Tipo I/metabolismo , Colágeno Tipo III/metabolismo , Antígeno Ki-67/metabolismo , Masculino , Metaloproteinase 2 da Matriz/metabolismo , Metaloproteinase 9 da Matriz/metabolismo , Modelos Animais , Ratos Sprague-Dawley , Resistência à Tração , Cicatrização/fisiologia
14.
Vet Pathol ; 52(2): 295-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24994621

RESUMO

The formation of biofilms on surgical implants is thought to play a major role in chronic infection and wound-healing disorders and has been rarely described in veterinary medicine. Due to poor and unreliable results from bacterial culturing, histology may be an economic tool for the detection of biofilms. In this study, the prevalence of biofilms on surgical suture materials and swabs with chronic wound-healing complications in dogs, cats, and horses was assessed by histologic examination using hematoxylin and eosin, Gram, and Giemsa stains, as well as periodic acid-Schiff reaction. Of the 91 tissue samples with intralesional suture material or swab residues associated with inflammation, only 2 contained bacterial colonies arranged in an extracellular polymeric matrix consistent with a biofilm. The results of this study suggest that biofilms on suture material may occur in veterinary medicine.


Assuntos
Biofilmes/crescimento & desenvolvimento , Doenças do Gato/microbiologia , Doenças do Cão/microbiologia , Doenças dos Cavalos/microbiologia , Animais , Gatos , Cães , Cavalos , Suturas/efeitos adversos , Suturas/veterinária
15.
Gastroenterology Res ; 17(4): 183-188, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39247708

RESUMO

Endoscopic retrograde cholangiopancreatography (ERCP) is an important technique for treating biliary obstruction. A case report of a 75-year-old male with diagnosed choledocholithiasis and cholangitis was presented. He had a history of hepatic surgery 45 years ago, and during the ERCP, an unusual clinical scenario was encountered. Retained extraction basket during ERCP is a rare but known complication and there are no standard recommendations to manage it. To our knowledge, this is the first case report described in the literature with retention of an extraction basket in surgical sutures at ERCP and the longest period from surgery to stone formation in the biliary system. This case report aims to emphasize that in patients with a history of hepatobiliary surgery, postoperative material can cause complications during ERCP.

16.
J Feline Med Surg ; 26(9): 1098612X241271871, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39287368

RESUMO

OBJECTIVES: The aim of this study was to evaluate, in vitro, the load and type of failure of the sutured ventral abdominal fascia of cats with different sizes of suture material made of polydioxanone (PDX) (2-0, 3-0, 4-0, 5-0 USP). METHODS: A total of 32 samples of the ventral abdominal wall from 16 cadaveric cats were harvested using an hourglass-shaped template. The samples were sectioned longitudinally along the linea alba and then sutured together in a continuous pattern using four different randomly assigned sizes of pdx suture material (2-0, 3-0, 4-0, 5-0 USP). A universal testing machine was used for linear distraction of the samples. The tensile strength and type of failure were recorded and analysed. Three types of failure were defined: suture material failure (S), suture line failure (T1) and failure of the abdominal wall further away from the linea alba (T2). RESULTS: The frequency of suture material failure decreased with increasing suture size. Suture size 5-0 failed due to a S failure in 6/8 samples, PDX 4-0 failed in 2/8 samples and PDX 3-0 failed in only 1/8 samples. However, PDX 2-0 failed due to only T1 or T2 failures, with both failures being almost equally represented. No statistically significant differences in the load to failure between PDX 2-0, 3-0 and 4-0 were noted (P >0.05). The risk of suture failure increased with decreasing suture size diameter. CONCLUSIONS AND RELEVANCE: PDX 2-0 and 3-0 can be used without reservation for the closure of ventral midline coeliotomy in cats. Although there was no statistically significant difference between PDX 2-0, 3-0 and 4-0, PDX 4-0 showed a higher probability for suture breakage and should be used only after careful consideration of the patient while clinical evaluation is pending. Pdx 5-0 cannot be recommended as a safe suture size for this type of surgical closure.


Assuntos
Polidioxanona , Técnicas de Sutura , Suturas , Resistência à Tração , Animais , Gatos , Suturas/veterinária , Técnicas de Sutura/veterinária , Fenômenos Biomecânicos , Parede Abdominal/cirurgia , Teste de Materiais/veterinária , Cadáver
17.
Materials (Basel) ; 17(15)2024 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-39124526

RESUMO

Sutures are natural or synthetic biomaterials utilized to hold tissues together. Following oral surgery, the surgical site and sutures are physically affected by many different factors. This study was conducted to evaluate the effect of artificial saliva (AS) and chlorhexidine mouthwash on the tensile strength of absorbable multifilament PGLA (polyglycolide-co-l-lactide) and non-absorbable multifilament silk sutures. PGLA and silk sutures, which are commonly used in oral surgery, were used to evaluate the change in strength of the sutures. A total of 352 suture samples were divided into eight equal groups (n = 44) and used for the experiments. Tensile strength was tested on days 0, 3, 7, and 14. For the silk sutures, there was a significant decrease in tensile strength in all groups at time T3 compared to T0, T1, and T2, and at times T1 and T2 compared to T0. For PGLA sutures, there was a significant decrease in all groups at time T3 compared to T0, T1, and T2. This study shows that chlorhexidine mouthwash significantly reduces suture resistance for 14 days after surgery.

18.
Materials (Basel) ; 17(14)2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39063878

RESUMO

Suture materials are natural or synthetic biomaterials used to close tissues together. After surgical procedures in the mouth, the surgical site and the sutures are physically affected by many different factors. This study was conducted to evaluate the effects of frequently consumed beverages on the tensile strength of monofilament PGLA (polyglycolide-co-l-lactide) and multi-filament PGCL (polyglycolide-co-caprolactone) absorbable sutures. In particular, PGLA and PGCL absorbable sutures, which are frequently used in oral surgery, were used to evaluate the change in the strength of suture materials. The suture materials were soaked in tea, coffee, and cola drinks five times a day for 5 min each and the rest of the time in artificial saliva. All suture materials were aged via thermal cycling. Tensile strengths were tested at 0, 3, 7, and 14 days. Mixed ANOVA (four replicates: within-group comparison and two factors: between-group comparison) was performed to evaluate the effects of groups and time on the tension levels of the Tekmon and Vicryl suture materials. Analysis of Variance was used for the within- and between-group comparisons, with the Bonferroni corrected t-test for multiple comparisons. For the PGCL suture material, there were significant decreases in tension levels in artificial saliva, tea, coffee, and cola at time T3 compared to T0, T1, and T2, and at T1 and T2 compared to T0. For the PGLA suture material, there were significant decreases in tension levels in artificial saliva, tea, coffee, and cola at time T3 compared to T0, T1, and T2. There was also a significant decrease in tension level at time T2 in cola compared to T0. The present study demonstrates that beverages significantly decrease the strength of suture materials for 14 days after surgery. In particular, cola decreased the resistance of the PGCL suture material more significantly in the first week when compared to other beverages.

19.
Int J Gynaecol Obstet ; 166(1): 389-396, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38243632

RESUMO

OBJECTIVES: To compare the tensile strength of fast absorbable Polyglactin 910 suture material when impregnated with various agents for local anesthesia and to investigate whether the presence of ethanol in Xylocaine spray could explain a potential reduction in tensile strength after use of Xylocaine spray. METHODS: In all, 120 suture samples of Polyglactin 910 were divided into four groups of 30. These four groups were randomly impregnated with isotonic sodium chloride, isotonic sodium chloride plus Xylocaine spray, isotonic sodium chloride plus Xylocaine gel, or isotonic sodium chloride plus ethanol. After impregnation, the sutures were stored in sealed glass tubes in a heating cabinet at 37°C for 72 h. Thereafter, the tensile strength of these 120 samples was assessed by a universal tensile testing machine. The maximal force needed to break the suture material was recorded in newtons (N). RESULTS: Fast absorbable Polyglactin 910 suture material impregnated with Xylocaine spray or ethanol showed weakened tensile strength (mean values 11.40 and 11.86 N, respectively), whereas the specimens impregnated with Xylocaine gel or sodium chloride retained their tensile strength better (mean values 13.81 and 13.28 N, respectively; mean difference between Xylocaine gel and Xylocaine spray -2.41 N, P < 0.001). CONCLUSION: In this in vitro experiment, ethanol and Xylocaine spray weakened the tensile strength of fast absorbable Polyglactin 910 sutures. Use of Xylocaine spray, which contains ethanol, for local anesthesia might lead to early breakdown of the suture material and wound rupture. The authors suggest caution when using Xylocaine spray in combination with fast absorbable Polyglactin 910 suture.


Assuntos
Anestésicos Locais , Etanol , Lidocaína , Poliglactina 910 , Suturas , Resistência à Tração , Anestésicos Locais/farmacologia , Anestésicos Locais/administração & dosagem , Lidocaína/farmacologia , Etanol/farmacologia , Teste de Materiais , Humanos , Cloreto de Sódio
20.
Arch Plast Surg ; 51(4): 386-396, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39034976

RESUMO

When repairing facial wounds, it is crucial to possess a thorough understanding of suitable suture materials and their evidence base. The absence of high-quality and comprehensive systematic reviews poses challenges in making informed decisions. In this study, we conducted a review of the existing literature and assessed the quality of the current evidence pertaining to the clinical, aesthetic, and patient-reported outcomes associated with absorbable and nonabsorbable sutures for facial skin closure. The study was registered on Prospective Register of Systematic Reviews. We conducted searches on Embase, Ovid, and PubMed/MEDLINE databases. Only randomized controlled trials (RCTs) were eligible for inclusion in this study. Additionally, the risk of bias in the randomized studies was assessed using Cochrane's Risk of Bias Tool. The study included a total of nine RCTs involving 804 participants with facial injuries. Among these injuries, absorbable sutures were utilized in 50.2% (403 injuries), while nonabsorbable sutures were employed in 49.8% (401 injuries). The analysis of cosmesis scales revealed no statistically significant difference between absorbable and nonabsorbable sutures regarding infections ( p = 0.72), visual analog scale ( p = 0.69), wound dehiscence ( p = 0.08), and scarring ( p = 0.46). The quality of the included studies was determined to have a low risk of bias. Absorbable sutures can be considered a suitable alternative to nonabsorbable sutures, as they demonstrate comparable aesthetic and clinical outcomes. Future high-quality studies with a level I evidence design and cost-effectiveness analysis are necessary to enhance clinician-patient shared decision-making and optimize the selection of suture materials. Level of evidence is I, risk/prognostic study.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa