Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
NMR Biomed ; 37(5): e5106, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38263738

RESUMO

PURPOSE: Both sodium T1 triple quantum (TQ) signal and T1 relaxation pathways have a unique sensitivity to the sodium molecular environment. In this study an inversion recovery time proportional phase increment (IRTQTPPI) pulse sequence was investigated for simultaneous and reliable quantification of sodium TQ signal and bi-exponential T1 relaxation times. METHODS: The IRTQTPPI sequence combines inversion recovery TQ filtering and time proportional phase increment. The reliable and reproducible results were achieved by the pulse sequence optimized in three ways: (1) optimization of the nonlinear fit for the determination of both T1-TQ signal and T1 relaxation times; (2) suppression of unwanted signals by assessment of four different phase cycles; (3) nonlinear sampling during evolution time for optimal scan time without any compromises in fit accuracy. The relaxation times T1 and T2 and the TQ signals from IRTQTPPI and TQTPPI were compared between 9.4 and 21.1 T. The motional environment of the sodium nuclei was evaluated by calculation of correlation times and nuclear quadrupole interaction strengths. RESULTS: Reliable measurements of the T1-TQ signals and T1 bi-exponential relaxation times were demonstrated. The fit parameters for all four phase cycles were in good agreement with one another, with a negligible influence of unwanted signals. The agar samples yielded normalized T1-TQ signals from 3% to 16% relative to single quantum (SQ) signals at magnetic fields of both 9.4 and 21.1 T. In comparison, the normalized T2-TQ signal was in the range 15%-35%. The TQ/SQ signal ratio was decreased at 21.1 T as compared with 9.4 T for both T1 and T2 relaxation pathways. The bi-exponential T1 relaxation time separation ranged from 15 to 18 ms at 9.4 T and 15 to 21 ms at 21.1 T. The T2 relaxation time separation was larger, ranging from 28 to 35 ms at 9.4 T and 37 to 40 ms at 21.1 T. CONCLUSION: The IRTQTPPI sequence, while providing a less intensive TQ signal than TQTPPI, allows a simultaneous and reliable quantification of both the T1-TQ signal and T1 relaxation times. The unique sensitivities of the T1 and T2 relaxation pathways to different types of molecular motion provide a deeper understanding of the sodium MR environment.


Assuntos
Imageamento por Ressonância Magnética , Sódio , Imageamento por Ressonância Magnética/métodos
2.
J Magn Reson Imaging ; 58(6): 1954-1963, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37026419

RESUMO

BACKGROUND: Preventing sepsis-associated acute kidney injury (S-AKI) can be challenging because it develops rapidly and is often asymptomatic. Probability assessment of disease progression for therapeutic follow-up and outcome are important to intervene and prevent further damage. PURPOSE: To establish a noninvasive multiparametric MRI (mpMRI) tool, including T1 , T2 , and perfusion mapping, for probability assessment of the outcome of S-AKI. STUDY TYPE: Preclinical randomized prospective study. ANIMAL MODEL: One hundred and forty adult female SD rats (65 control and 75 sepsis). FIELD STRENGTH/SEQUENCE: 9.4T; T1 and perfusion map (FAIR-EPI) and T2 map (multiecho RARE). ASSESSMENT: Experiment 1: To identify renal injury in relation to sepsis severity, serum creatinine levels were determined (31 control and 35 sepsis). Experiment 2: Animals underwent mpMRI (T1 , T2 , perfusion) 18 hours postsepsis. A subgroup of animals was immediately sacrificed for histology examination (nine control and seven sepsis). Result of mpMRI in follow-up subgroup (25 control and 33 sepsis) was used to predict survival outcomes at 96 hours. STATISTICAL TESTS: Mann-Whitney U test, Spearman/Pearson correlation (r), P < 0.05 was considered statistically significant. RESULTS: Severely ill septic animals exhibited significantly increased serum creatinine levels compared to controls (70 ± 30 vs. 34 ± 9 µmol/L, P < 0.0001). Cortical perfusion (480 ± 80 vs. 330 ± 140 mL/100 g tissue/min, P < 0.005), and cortical and medullary T2 relaxation time constants were significantly reduced compared to controls (41 ± 4 vs. 37 ± 5 msec in cortex, P < 0.05, 52 ± 7 vs. 45 ± 6 msec in medulla, P < 0.05). The combination of cortical T2 relaxation time constants and perfusion results at 18 hours could predict survival outcomes at 96 hours with high sensitivity (80%) and specificity (73%) (area under curve of ROC = 0.8, Jmax = 0.52). DATA CONCLUSION: This preclinical study suggests combined T2 relaxation time and perfusion mapping as first line diagnostic tool for treatment planning. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Injúria Renal Aguda , Sepse , Feminino , Ratos , Animais , Estudos Prospectivos , Creatinina , Ratos Sprague-Dawley , Injúria Renal Aguda/diagnóstico por imagem , Injúria Renal Aguda/patologia , Imageamento por Ressonância Magnética , Perfusão , Sepse/complicações , Sepse/diagnóstico por imagem
3.
Sensors (Basel) ; 22(3)2022 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-35162007

RESUMO

Magnetic resonance fingerprinting (MRF) based on echo-planar imaging (EPI) enables whole-brain imaging to rapidly obtain T1 and T2* relaxation time maps. Reconstructing parametric maps from the MRF scanned baselines by the inner-product method is computationally expensive. We aimed to accelerate the reconstruction of parametric maps for MRF-EPI by using a deep learning model. The proposed approach uses a two-stage model that first eliminates noise and then regresses the parametric maps. Parametric maps obtained by dictionary matching were used as a reference and compared with the prediction results of the two-stage model. MRF-EPI scans were collected from 32 subjects. The signal-to-noise ratio increased significantly after the noise removal by the denoising model. For prediction with scans in the testing dataset, the mean absolute percentage errors between the standard and the final two-stage model were 3.1%, 3.2%, and 1.9% for T1, and 2.6%, 2.3%, and 2.8% for T2* in gray matter, white matter, and lesion locations, respectively. Our proposed two-stage deep learning model can effectively remove noise and accurately reconstruct MRF-EPI parametric maps, increasing the speed of reconstruction and reducing the storage space required by dictionaries.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Aceleração , Atenção , Encéfalo/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Redes Neurais de Computação , Imagens de Fantasmas
4.
Magn Reson Med ; 83(6): 1895-1908, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31729080

RESUMO

PURPOSE: This assesses the potential of measuring lactate in the human brain using three non-editing MRS methods at 7T and compares the accuracy and precision of the methods. METHODS: 1 H MRS data were measured in the right dorsolateral prefrontal cortex using a semi-adiabatic spin-echo full-intensity acquired localized sequence with three different protocols: (I) TE = 16 ms, (II) TE = 110 ms, and (III) TE = 16 ms, TI = 300 ms. T1 and T2 relaxation times of lactate were also measured. Simulated spectra were generated for three protocols with known concentrations, using a range of spectral linewidths and SNRs to assess the effect of data quality on the measurement precision and accuracy. RESULTS: Lactate was quantified in all three protocols with mean Cramér-Rao lower bound of 8% (I), 13% (II), and 7% (III). The T1 and T2 relaxation times of lactate were 1.9 ± 0.2 s and 94 ± 13 ms, respectively. Simulations predicted a spectral linewidth-associated underestimation of lactate measurement. Simulations, phantom and in vivo results showed that protocol II was most affected by this underestimation. In addition, the estimation error was insensitive to a broad range of spectral linewidth with protocol I. Within-session coefficient of variances of lactate were 6.1 ± 7.9% (I), 22.3 ± 12.3% (II), and 5.1 ± 5.4% (III), respectively. CONCLUSION: We conclude that protocols I and III have the potential to measure lactate at 7T with good reproducibility, whereas the measurement accuracy and precision depend on spectral linewidth and SNR, respectively. Moreover, simulation is valuable for the optimization of measurement protocols in future study design and the correction for measurement bias.


Assuntos
Encéfalo , Córtex Pré-Frontal , Humanos , Lactatos , Espectroscopia de Ressonância Magnética , Córtex Pré-Frontal/diagnóstico por imagem , Reprodutibilidade dos Testes
5.
NMR Biomed ; 31(2)2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29160917

RESUMO

1 H magnetic resonance imaging (MRI) by a zero echo time (ZTE) sequence is an excellent method to image teeth. Calcium phosphate cement (CPC) materials are applied in the restoration of tooth lesions, but it has not yet been investigated whether they can be detected by computed tomography (CT) or MRI. The aim of this study was to optimize high-field ZTE imaging to enable the visualization of a new CPC formulation implanted in teeth and to apply this in the assessment of its decomposition in vivo. CPC was implanted in three human and three goat teeth ex vivo and in three goat teeth in vivo. An ultrashort echo time (UTE) sequence with multiple flip angles and echo times was applied at 11.7 T to measure T1 and T2 * values of CPC, enamel and dentin. Teeth with CPC were imaged with an optimized ZTE sequence. Goat teeth implanted with CPC in vivo were imaged after 7 weeks ex vivo. T2 * relaxation of implanted CPC, dentin and enamel was better fitted by a model assuming a Gaussian rather than a Lorentzian distribution. For CPC and human enamel and dentin, the average T2 * values were 273 ± 19, 562 ± 221 and 476 ± 147 µs, respectively, the average T2 values were 1234 ± 27, 963 ± 151 and 577 ± 41 µs, respectively, and the average T1 values were 1065 ± 45, 972 ± 40 and 903 ± 7 ms, respectively. In ZTE images, CPC had a higher signal-to-noise-ratio than dentin and enamel because of the higher water content. Seven weeks after in vivo implantation, the CPC-filled lesions showed less homogeneous structures, a lower T1 value and T2 * separated into two components. MRI by ZTE provides excellent contrast for CPC in teeth and allows its decomposition to be followed.


Assuntos
Cimentos Ósseos/análise , Fosfatos de Cálcio/análise , Imageamento por Ressonância Magnética , Dente/química , Animais , Dentina/química , Cabras , Humanos , Razão Sinal-Ruído , Fatores de Tempo , Água/química
6.
MAGMA ; 29(5): 777-88, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27160300

RESUMO

OBJECTIVE: To segment and classify the different attenuation regions from MRI at the pelvis level using the T 1 and T 2 relaxation times and anatomical knowledge as a first step towards the creation of PET/MR attenuation maps. MATERIALS AND METHODS: Relaxation times were calculated by fitting the pixel-wise intensities of acquired T 1- and T 2-weighted images from eight men with inversion-recovery and multi-echo multi-slice spin-echo sequences. A decision binary tree based on relaxation times was implemented to segment and classify fat, muscle, prostate, and air (within the body). Connected component analysis and an anatomical knowledge-based procedure were implemented to localize the background and bone. RESULTS: Relaxation times at 3 T are reported for fat (T 1 = 385 ms, T 2 = 121 ms), muscle (T 1 = 1295 ms, T 2 = 40 ms), and prostate (T 1 = 1700 ms, T 2 = 80 ms). The relaxation times allowed the segmentation-classification of fat, prostate, muscle, and air, and combined with anatomical knowledge, they allowed classification of bone. The good segmentation-classification of prostate [mean Dice similarity score (mDSC) = 0.70] suggests a viable implementation in oncology and that of fat (mDSC = 0.99), muscle (mDSC = 0.99), and bone (mDSCs = 0.78) advocates for its implementation in PET/MR attenuation correction. CONCLUSION: Our method allows the segmentation and classification of the attenuation-relevant structures required for the generation of the attenuation map of PET/MR systems in prostate imaging: air, background, bone, fat, muscle, and prostate.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Algoritmos , Artefatos , Árvores de Decisões , Humanos , Masculino , Músculos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Fatores de Tempo
7.
J Fungi (Basel) ; 10(10)2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-39452669

RESUMO

Truffles of the Tuber genus (Pezizales, Ascomycetes) are among the most valuable and expensive foods, but their shelf life is limited to 7-10 days when stored at 4 °C. Alternative preservation methods have been proposed to extend their shelf life, though they may alter certain quality parameters. Recently, a hypogeal display case equipped with an ultrasonic humidity system (HDC) was developed, extending the shelf life to 2-3 weeks, depending on the truffle species. This study assesses the efficacy of HDC in preserving Tuber melanosporum and Tuber borchii ascomata over 16 days, using quantitative magnetic resonance imaging (QMRI) to monitor water content and other parameters. Sixteen T. melanosporum and six T. borchii ascomata were stored at 4 °C in an HDC or a static fridge (SF) as controls. QMRI confirmed that T. borchii has a shorter shelf life than T. melanosporum under all conditions. HDC reduced the rate of shrinkage, water, and mass loss in both species. Additionally, the Apparent Diffusion Coefficient (ADC), longitudinal relaxation time (T1), and transverse relaxation time (T2), which reflect molecular changes, decreased more slowly in HDC than SF. QMRI proves useful for studying water-rich samples and assessing truffle preservation technologies. Further optimization of this method for industrial use is needed.

8.
Cancers (Basel) ; 14(3)2022 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-35158990

RESUMO

(1) Background: Advanced MR imaging (MRI) of brain tumors is mainly based on qualitative contrast images. MR Fingerprinting (MRF) offers a novel approach. The purpose of this study was to use MRF-derived T1 and T2 relaxation maps to differentiate diffuse gliomas according to isocitrate dehydrogenase (IDH) mutation. (2) Methods: Twenty-four patients with histologically verified diffuse gliomas (14 IDH-mutant, four 1p/19q-codeleted, 10 IDH-wildtype) were enrolled. MRF T1 and T2 relaxation times were compared to apparent diffusion coefficient (ADC), relative cerebral blood volume (rCBV) within solid tumor, peritumoral edema, and normal-appearing white matter (NAWM), using contrast-enhanced MRI, diffusion-, perfusion-, and susceptibility-weighted imaging. For perfusion imaging, a T2* weighted perfusion sequence with leakage correction was used. Correlations of MRF T1 and T2 times with two established conventional sequences for T1 and T2 mapping were assessed (a fast double inversion recovery-based MR sequence ('MP2RAGE') for T1 quantification and a multi-contrast spin echo-based sequence for T2 quantification). (3) Results: MRF T1 and T2 relaxation times were significantly higher in the IDH-mutant than in IDH-wildtype gliomas within the solid part of the tumor (p = 0.024 for MRF T1, p = 0.041 for MRF T2). MRF T1 and T2 relaxation times were significantly higher in the IDH-wildtype than in IDH-mutant gliomas within peritumoral edema less than or equal to 1cm adjacent to the tumor (p = 0.038 for MRF T1 mean, p = 0.010 for MRF T2 mean). In the solid part of the tumor, there was a high correlation between MRF and conventionally measured T1 and T2 values (r = 0.913, p < 0.001 for T1, r = 0.775, p < 0.001 for T2), as well as between MRF and ADC values (r = 0.813, p < 0.001 for T2, r = 0.697, p < 0.001 for T1). The correlation was weak between the MRF and rCBV values (r = -0.374, p = 0.005 for T2, r = -0.181, p = 0.181 for T1). (4) Conclusions: MRF enables fast, single-sequence based, multi-parametric, quantitative tissue characterization of diffuse gliomas and may have the potential to differentiate IDH-mutant from IDH-wildtype gliomas.

9.
Med Phys ; 48(5): 2438-2447, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33690905

RESUMO

PURPOSE: To compare the bias and inherent reliability of the quantitative (T1 and T2 ) imaging metrics generated from the magnetic resonance fingerprinting (MRF) technique using the ISMRM/NIST system phantom in an international multicenter setting. METHOD: ISMRM/NIST MRI system phantom provides standard reference T1 and T2 relaxation values (vendor-provided) for each of the 14 vials in T1 and T2 arrays. MRF-SSFP scans repeated over 30 days on GE 1.5 and 3.0 T scanners at three collaborative centers. MRF estimated T1, and T2 values averaged over 30 days were compared with the phantom vendor-provided and spin-echo (SE) based convention gold standard (GS) method. Repeatability and reproducibility were characterized by the within-case coefficient of variation (wCV) of the MRF data acquired over 30 days, along with the biases. RESULT: For the wide ranges of MRF estimated T1 values, vials #1-8 (T1 relaxation time between 2033 and 184 ms) exhibited a wCV less than 3% and 4%, respectively, on 3.0 and 1.5 T scanners. T2 values in vials #1-8 (T2 relaxation, 1044-45 ms) have shown wCV to be <7% on both 3.0 and 1.5 T scanners. A stronger linear correlation overall for T1 (R2  = 0.9960 and 0.9963 at center-1 and center-2 on 3.0 T scanner, and R2  = 0.9951 and 0.9988 at center-1 and center-3 on 1.5 T scanner) compared to T2 (R2  = 0.9971 and 0.9972 at center-1 and center-2 on 3.0 T scanner, and R2  = 0.9815 and 0.9754 at center-1 and center-3 on 1.5 T scanner). Bland-Altman (BA) analysis showed MRF based T1 and T2 values were within the limit of agreement (LOA) except for one data point. The mean difference or bias and 95% lower bound (LB) and upper bound (UB) LOA are reported in the format; mean bias: 95% LB LOA: 95% UB LOA. The biases for T1 values were 21.34: -50.00: 92.69, 21.32: -47.29: 89.94 ms, and for T2 values were -19.88: -42.37: 2.61, -19.06: -43.58: 5.45 ms on 3.0 T scanner at center-1 and center-2, respectively. Similarly, on 1.5 T scanner biases for T1 values were 26.54: -53.41: 106.50, 9.997: -51.94: 71.94 ms, and for T2 values were -23.84: -135.40: 87.76, -37.30: 134.30: 59.73 ms at center-1 and center-3, respectively. Additionally, the correlation between the SE based GS and MRF estimated T1 and T2 values (R2  = 0.9969 and 0.9977) showed a similar trend as we observed between vendor-provided and MRF estimated T1 and T2 values (R2  = 0.9963 and 0.9972). In addition to correlation, BA analysis showed that all the vials are within the LOA between the GS and vendor-provided for the T1 values and except one vial for T2 . All the vials are within the LOA between GS and MRF except one vial in T1 and T2 array. The wCV for reproducibility was <3% for both T1 and T2 values in vials #1-8, for all the 14 vials, wCV calculated for reproducibility was <4% for T1 values and <5% for T2 . CONCLUSION: This study shows that MRF is highly repeatable (wCV <4% for T1 and <7% for T2 ) and reproducible (wCV < 3% for both T1 and T2 ) in certain vials (vials #1-8).


Assuntos
Benchmarking , Imageamento por Ressonância Magnética , Processamento de Imagem Assistida por Computador , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Reprodutibilidade dos Testes
10.
Front Chem ; 9: 709581, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34336792

RESUMO

For wide applications of the lacZ gene in cellular/molecular biology, small animal investigations, and clinical assessments, the improvement of noninvasive imaging approaches to precisely assay gene expression has garnered much attention. In this study, we investigate a novel molecular platform in which alizarin 2-O-ß-d-galactopyranoside AZ-1 acts as a lacZ gene/ß-gal responsive 1H-MRI probe to induce significant 1H-MRI contrast changes in relaxation times T 1 and T 2 in situ as a concerted effect for the discovery of ß-gal activity with the exposure of Fe3+. We also demonstrate the capability of this strategy for detecting ß-gal activity with lacZ-transfected human MCF7 breast and PC3 prostate cancer cells by reaction-enhanced 1H-MRI T 1 and T 2 relaxation mapping.

11.
Quant Imaging Med Surg ; 10(6): 1237-1248, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32550133

RESUMO

BACKGROUND: Despite increasing reports of 3D printing in medical applications, the use of 3D printing in breast imaging is limited, thus, personalized 3D-printed breast model could be a novel approach to overcome current limitations in utilizing breast magnetic resonance imaging (MRI) for quantitative assessment of breast density. The aim of this study is to develop a patient-specific 3D-printed breast phantom and to identify the most appropriate materials for simulating the MR imaging characteristics of fibroglandular and adipose tissues. METHODS: A patient-specific 3D-printed breast model was generated using 3D-printing techniques for the construction of the hollow skin and fibroglandular region shells. Then, the T1 relaxation times of the five selected materials (agarose gel, silicone rubber with/without fish oil, silicone oil, and peanut oil) were measured on a 3T MRI system to determine the appropriate ones to represent the MR imaging characteristics of fibroglandular and adipose tissues. Results were then compared to the reference values of T1 relaxation times of the corresponding tissues: 1,324.42±167.63 and 449.27±26.09 ms, respectively. Finally, the materials that matched the T1 relaxation times of the respective tissues were used to fill the 3D-printed hollow breast shells. RESULTS: The silicone and peanut oils were found to closely resemble the T1 relaxation times and imaging characteristics of these two tissues, which are 1,515.8±105.5 and 405.4±15.1 ms, respectively. The agarose gel with different concentrations, ranging from 0.5 to 2.5 wt%, was found to have the longest T1 relaxation times. CONCLUSIONS: A patient-specific 3D-printed breast phantom was successfully designed and constructed using silicone and peanut oils to simulate the MR imaging characteristics of fibroglandular and adipose tissues. The phantom can be used to investigate different MR breast imaging protocols for the quantitative assessment of breast density.

12.
J Med Imaging Radiat Sci ; 50(4): 575-589, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31727524

RESUMO

INTRODUCTION: Magnetic resonance imaging (MRI) is a well-established medical invention in modern medical technology diagnosis. It is a nondestructive, versatile, and sensitive technique with a high spatial resolution for medical diagnosis. However, MRI has some limitations in differentiating certain tissues, particularly tiny blood vessels, pathological to healthy tissues, specific tumors, and inflammatory conditions such as arthritis, atherosclerosis, and multiple sclerosis. The contrast agent (CA) assisted imaging is the best possible solution to resolve the limitations of MRI. METHOD: The literature review was carried out using the keywords, "MRI, T1&T2 relaxation, MRI CAs, delivery and adverse effects, classification of CAs." The tools used for the literature search were PubMed, Scopus, and Google Scholar. RESULT AND DISCUSSION: The literature findings focus on MRI technique, limitations, and possible solutions. Primarily, the review focuses on the mechanism of CAs in image formation with detailed explanations of T1 and T2 relaxations, the mechanism of the MRI-CA image formations. This review presents the adverse effects of CA as well as available marketed formulations and recent patents to extent complete information about the MRI-CA. CONCLUSION: MRI generates detailed visual information of various tissues with high resolution and contrast. The proton present in the biological fluid plays a crucial role in MR image formation, and it is unable to distinguish pathological conditions in many cases. The CAs are the best solution to resolve the limitation by interacting with native protons. The present review discusses the mechanism of CAs in contrast enhancement and its broad classification with the latest literature. Furthermore, the article presents information about CA biodistribution and adverse effects. The review concludes with an appropriate solution for adverse effects and presents the future prospective for researchers to develop advanced formulations.


Assuntos
Meios de Contraste/classificação , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico , Humanos
13.
J Med Signals Sens ; 8(4): 244-252, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30603617

RESUMO

BACKGROUND: Noninvasive quantification of liver fat by gradient echo (GRE) technique is an interesting issue in quantitative magnetic resonance imaging. In this study, the fat content in patients with nonalcoholic fatty liver disease (NAFLD) was quantified with GRE sequences with different T 1 and T 2* weighting. METHODS: This prospective, cross-sectional study was performed on thirty NAFLD patients. Sixteen GRE sequences with different T 1 weighting were performed with four echo times. In each sequence, repetition time (TR) or flip angle was changed and other parameters were fixed. Forty-eight fat indexes (FIs) from 16 sequences were calculated based on three methods. To determine the relationship between FIs and histological findings, Pearson's correlation coefficient was used at the level of 1% significance. RESULTS: Mean FIs which obtained from Eq. 3 have the maximum values in comparison to other FIs. The maximum FI was 23.58%, which related to heavily T 1 weighted sequence obtained with method 3. The minimum FI was -2.49%, which related to the minimal T 1 weighted obtained with method 2. FIs increase with a flip angle, especially at low flip angles. Increase the TR parameter decrease the FIs gradually. Calculated FIs with methods 1 and 3 stronger correlated with histological findings relative to calculated FIs with method 2. CONCLUSION: For fat quantification, T 1 relaxation effects probably more critical than T 2*. Flip angle parameter could be a major factor causing the overestimation of liver fat content. Sequences with low flip angle are more suitable for fat quantification with methods 1 and 3. In fat quantification with GRE techniques, it is possible that the third and fourth echoes are unnecessary.

14.
J Magn Reson ; 259: 56-67, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26295169

RESUMO

The fundamental basis of T1 and T2 contrast in brain MRI is not well understood; recent literature contains conflicting views on the nature of relaxation in white matter (WM). We investigated the effects of inversion pulse bandwidth on measurements of T1 and T2 in WM. Hybrid inversion-recovery/Carr-Purcell-Meiboom-Gill experiments with broad or narrow bandwidth inversion pulses were applied to bovine WM in vitro. Data were analysed with the commonly used 1D-non-negative least squares (NNLS) algorithm, a 2D-NNLS algorithm, and a four-pool model which was based upon microscopically distinguishable WM compartments (myelin non-aqueous protons, myelin water, non-myelin non-aqueous protons and intra/extracellular water) and incorporated magnetization exchange between adjacent compartments. 1D-NNLS showed that different T2 components had different T1 behaviours and yielded dissimilar results for the two inversion conditions. 2D-NNLS revealed significantly more complicated T1/T2 distributions for narrow bandwidth than for broad bandwidth inversion pulses. The four-pool model fits allow physical interpretation of the parameters, fit better than the NNLS techniques, and fits results from both inversion conditions using the same parameters. The results demonstrate that exchange cannot be neglected when analysing experimental inversion recovery data from WM, in part because it can introduce exponential components having negative amplitude coefficients that cannot be correctly modeled with nonnegative fitting techniques. While assignment of an individual T1 to one particular pool is not possible, the results suggest that under carefully controlled experimental conditions the amplitude of an apparent short T1 component might be used to quantify myelin water.


Assuntos
Espectroscopia de Ressonância Magnética/métodos , Substância Branca/química , Algoritmos , Animais , Água Corporal/química , Bovinos , Espaço Extracelular/química , Análise dos Mínimos Quadrados , Espectroscopia de Ressonância Magnética/estatística & dados numéricos , Modelos Estatísticos , Bainha de Mielina/química
15.
J Med Imaging (Bellingham) ; 1(3): 035502, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26158073

RESUMO

Medical imaging is an effective technique used to detect and prevent disease in cancer research. To optimize medical imaging, a calibration medium or phantom with tissue-mimicking properties is required. Although the feasibility of various polymer gel materials has previously been studied, the stability of the gels' properties has not been investigated. In this study, we fabricated carrageenan-based polymer gel to examine the stability of its properties such as density, conductivity, permittivity, elastic modulus, and [Formula: see text] and [Formula: see text] relaxation times over six weeks. We fabricated eight samples with different carrageenan and agar concentrations and found that the density, elastic modulus, and compressive strength fluctuated with no specific pattern. The elastic modulus in sample 4 with 3 wt. % carrageenan and 1.5 wt. % agar fluctuated from 0.51 to 0.64 MPa in five weeks. The [Formula: see text] and [Formula: see text] relaxation times also varied by 23% to 29%. We believe that the fluctuation of these properties is related to the change in water content of the sample due to cycles of water expulsion and absorption in their containers. The fluctuation of the properties should be minimized to achieve accurate calibration over the shelf life of the phantom and to serve as the standard for quality assurance. Furthermore, a full liver phantom with spherical lesion particles was fabricated to demonstrate the potential for phantom production.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa