Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 58(6): 1954-1963, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37026419

RESUMO

BACKGROUND: Preventing sepsis-associated acute kidney injury (S-AKI) can be challenging because it develops rapidly and is often asymptomatic. Probability assessment of disease progression for therapeutic follow-up and outcome are important to intervene and prevent further damage. PURPOSE: To establish a noninvasive multiparametric MRI (mpMRI) tool, including T1 , T2 , and perfusion mapping, for probability assessment of the outcome of S-AKI. STUDY TYPE: Preclinical randomized prospective study. ANIMAL MODEL: One hundred and forty adult female SD rats (65 control and 75 sepsis). FIELD STRENGTH/SEQUENCE: 9.4T; T1 and perfusion map (FAIR-EPI) and T2 map (multiecho RARE). ASSESSMENT: Experiment 1: To identify renal injury in relation to sepsis severity, serum creatinine levels were determined (31 control and 35 sepsis). Experiment 2: Animals underwent mpMRI (T1 , T2 , perfusion) 18 hours postsepsis. A subgroup of animals was immediately sacrificed for histology examination (nine control and seven sepsis). Result of mpMRI in follow-up subgroup (25 control and 33 sepsis) was used to predict survival outcomes at 96 hours. STATISTICAL TESTS: Mann-Whitney U test, Spearman/Pearson correlation (r), P < 0.05 was considered statistically significant. RESULTS: Severely ill septic animals exhibited significantly increased serum creatinine levels compared to controls (70 ± 30 vs. 34 ± 9 µmol/L, P < 0.0001). Cortical perfusion (480 ± 80 vs. 330 ± 140 mL/100 g tissue/min, P < 0.005), and cortical and medullary T2 relaxation time constants were significantly reduced compared to controls (41 ± 4 vs. 37 ± 5 msec in cortex, P < 0.05, 52 ± 7 vs. 45 ± 6 msec in medulla, P < 0.05). The combination of cortical T2 relaxation time constants and perfusion results at 18 hours could predict survival outcomes at 96 hours with high sensitivity (80%) and specificity (73%) (area under curve of ROC = 0.8, Jmax = 0.52). DATA CONCLUSION: This preclinical study suggests combined T2 relaxation time and perfusion mapping as first line diagnostic tool for treatment planning. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Injúria Renal Aguda , Sepse , Feminino , Ratos , Animais , Estudos Prospectivos , Creatinina , Ratos Sprague-Dawley , Injúria Renal Aguda/diagnóstico por imagem , Injúria Renal Aguda/patologia , Imageamento por Ressonância Magnética , Perfusão , Sepse/complicações , Sepse/diagnóstico por imagem
2.
NMR Biomed ; 31(2)2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29160917

RESUMO

1 H magnetic resonance imaging (MRI) by a zero echo time (ZTE) sequence is an excellent method to image teeth. Calcium phosphate cement (CPC) materials are applied in the restoration of tooth lesions, but it has not yet been investigated whether they can be detected by computed tomography (CT) or MRI. The aim of this study was to optimize high-field ZTE imaging to enable the visualization of a new CPC formulation implanted in teeth and to apply this in the assessment of its decomposition in vivo. CPC was implanted in three human and three goat teeth ex vivo and in three goat teeth in vivo. An ultrashort echo time (UTE) sequence with multiple flip angles and echo times was applied at 11.7 T to measure T1 and T2 * values of CPC, enamel and dentin. Teeth with CPC were imaged with an optimized ZTE sequence. Goat teeth implanted with CPC in vivo were imaged after 7 weeks ex vivo. T2 * relaxation of implanted CPC, dentin and enamel was better fitted by a model assuming a Gaussian rather than a Lorentzian distribution. For CPC and human enamel and dentin, the average T2 * values were 273 ± 19, 562 ± 221 and 476 ± 147 µs, respectively, the average T2 values were 1234 ± 27, 963 ± 151 and 577 ± 41 µs, respectively, and the average T1 values were 1065 ± 45, 972 ± 40 and 903 ± 7 ms, respectively. In ZTE images, CPC had a higher signal-to-noise-ratio than dentin and enamel because of the higher water content. Seven weeks after in vivo implantation, the CPC-filled lesions showed less homogeneous structures, a lower T1 value and T2 * separated into two components. MRI by ZTE provides excellent contrast for CPC in teeth and allows its decomposition to be followed.


Assuntos
Cimentos Ósseos/análise , Fosfatos de Cálcio/análise , Imageamento por Ressonância Magnética , Dente/química , Animais , Dentina/química , Cabras , Humanos , Razão Sinal-Ruído , Fatores de Tempo , Água/química
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa