Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 336
Filtrar
1.
Small ; : e2401422, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39118560

RESUMO

Silica-supported amine absorbents, including materials produced by tethering aminosilanes or infusion of poly(ethyleneimine), represent a promising class of materials for CO2 capture applications, including direct air and point source capture. Various silica surface treatments and functionalization strategies are explored to enhance stability and CO2 uptake in amine-based solid sorbent systems. Here, the synthesis and characterization of novel vinyltrimethoxysilane-treated Santa Barbara Amorphous-15 (SBA-15) supports and the corresponding enhancement in CO2 uptake compared to various SBA-15-based control supports are presented. The relationship between CO2 diffusion and amine efficiency in these systems is explored using a previously reported kinetic model. The synthesized materials are characterized with CO2 and H2O isotherms, diffuse reflectance infrared Fourier transform spectroscopy, 1H T1-T2 relaxation correlation NMR, and rapid thermal cycling experiments. The novel support materials are shown to enable high amine efficiencies, approaching a fourfold improvement over standard SBA-15-supported amines, while simultaneously exhibiting excellent stability when cycled rapidly under humid conditions. As the poly(ethyleneimine) loadings are held constant across the various samples, enhancements in CO2 uptake are attributed to differences in the way the poly(ethyleneimine) interacts with the support surface.

2.
Biol Reprod ; 110(6): 1065-1076, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38442734

RESUMO

Although the central role of adequate blood flow and oxygen delivery is known, the lack of optimized imaging modalities to study placental structure has impeded our understanding of its vascular function. Magnetic resonance imaging is increasingly being applied in this field, but gaps in knowledge remain, and further methodological developments are needed. In particular, the ability to distinguish maternal from fetal placental perfusion and the understanding of how individual placental lobules are functioning are lacking. The potential clinical benefits of developing noninvasive tools for the in vivo assessment of blood flow and oxygenation, two key determinants of placental function, are tremendous. Here, we summarize a number of structural and functional magnetic resonance imaging techniques that have been developed and applied in animal models and studies of human pregnancy over the past decade. We discuss the potential applications and limitations of these approaches. Their combination provides a novel source of contrast to allow analysis of placental structure and function at the level of the lobule. We outline the physiological mechanisms of placental T2 and T2* decay and devise a model of how tissue composition affects the observed relaxation properties. We apply this modeling to longitudinal magnetic resonance imaging data obtained from a preclinical pregnant nonhuman primate model to provide initial proof-of-concept data for this methodology, which quantifies oxygen transfer and placental structure across and between lobules. This method has the potential to improve our understanding and clinical management of placental insufficiency once validation in a larger nonhuman primate cohort is complete.


Assuntos
Imageamento por Ressonância Magnética , Placenta , Animais , Feminino , Gravidez , Imageamento por Ressonância Magnética/métodos , Placenta/diagnóstico por imagem , Placenta/fisiologia , Primatas , Modelos Animais
3.
Magn Reson Med ; 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39164611

RESUMO

PURPOSE: This study aims to assess how T2 heterogeneity biases IMPULSED-derived metrics of tissue microstructure in solid tumors and evaluate the potential of estimating multi-compartmental T2 and microstructural parameters simultaneously. METHODS: This study quantifies the impact of T2 relaxation on IMPULSED-derived microstructural parameters using computer simulations and in vivo multi-TE IMPULSED MRI in five tumor models, including brain, breast, prostate, melanoma, and colon cancer. A comprehensive T2 + IMPULSED method was developed to fit multi-compartmental T2 and microstructural parameters simultaneously. A Bayesian model selection approach was carried out voxel-wisely to determine if the T2 heterogeneity needs to be included in IMPULSED MRI in cancer. RESULTS: Simulations suggest that T2 heterogeneity has a minor effect on the estimation of d in tissues with intermediate or high cell density, but significantly biases the estimation of v in $$ {v}_{in} $$ with low cell density. For the in vivo animal experiments, all IMPULSED metrics except v in $$ {v}_{in} $$ are statistically independent on TE. For B16 tumors, the IMPULSED-derived v in $$ {v}_{in} $$ exhibited a notable increase with longer TEs. For MDA-MB-231 tumors, IMPULSED-derived v in $$ {v}_{in} $$ showed a significant increase with increasing TEs. The T2 + IMPULSED-derived T 2 in $$ {T}_2^{in} $$ of all five tumor models are consistently smaller than T 2 ex $$ {T}_2^{ex} $$ . CONCLUSIONS: The findings from this study highlight two key observations: (i) TE has a negligible impact on IMPULSED-derived cell sizes, and (ii) the TE-dependence of IMPULSED-derived intracellular volume fractions used in T2 + IMPULSED modeling to estimate T 2 in $$ {T}_2^{in} $$ and T 2 ex $$ {T}_2^{ex} $$ . These insights contribute to the ongoing development and refinement of non-invasive MRI techniques for measuring cell sizes.

4.
Magn Reson Med ; 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39313759

RESUMO

PURPOSE: To compare the performance of a learned magnetization-prepared gradient echo (L-MPGRE) sequence against a commonly used sequence for 3D T2 and T1ρ mapping of the knee joint, the magnetization-prepared angle-modulated partitioned k-space spoiled gradient echo snapshots (MAPSS), on bi-exponential (BE), stretched-exponential (SE), and mono-exponential (ME) relaxation models. METHODS: We used a combined differentiable and non-differentiable optimization to learn pulse sequence structure and its parameters for 3D T2 and T1ρ mapping of the knee joint using ME, SE, and BE models. The learned pulse sequence framework was used to improve quantitative accuracy and SNR and to reduce filtering effects. We compare the measured multi-compartment values between the two sequences (n = 8), and their repeatability (n = 4) in healthy volunteers (n = 12 total). RESULTS: The voxel-wise median absolute percentage difference (MAPD) between the T2 and T1ρ maps obtained with each sequence was 18.6% and 19.9%, respectively. The T2 and T1ρ repeatability tests showed a MAPD of 18.5% and 19.1% for MAPSS, and 16.8% and 15.5% for L-MPGRE. Bland-Altman region of interest (ROI)-wise analysis shows that bias is small, close to -1.5%, and the coefficient of variation is around 5.5% when comparing ROIs from both sequences. CONCLUSION: The L-MPGRE sequences can be used as a replacement for MAPSS for T2 and T1ρ mapping in the knee cartilage with advantages, achieving similar accuracy and 15% better repeatability in only half of its scan time.

5.
NMR Biomed ; 37(3): e5069, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37990759

RESUMO

Quantitative T2-weighted MRI (T2W) interpretation is impeded by the variability of acquisition-related features, such as field strength, coil type, signal amplification, and pulse sequence parameters. The main purpose of this work is to develop an automated method for prostate T2W intensity normalization. The procedure includes the following: (i) a deep learning-based network utilizing MASK R-CNN for automatic segmentation of three reference tissues: gluteus maximus muscle, femur, and bladder; (ii) fitting a spline function between average intensities in these structures and reference values; and (iii) using the function to transform all T2W intensities. The T2W distributions in the prostate cancer regions of interest (ROIs) and normal appearing prostate tissue (NAT) were compared before and after normalization using Student's t-test. The ROIs' T2W associations with the Gleason Score (GS), Decipher genomic score, and a three-tier prostate cancer risk were evaluated with Spearman's correlation coefficient (rS ). T2W differences in indolent and aggressive prostate cancer lesions were also assessed. The MASK R-CNN was trained with manual contours from 32 patients. The normalization procedure was applied to an independent MRI dataset from 83 patients. T2W differences between ROIs and NAT significantly increased after normalization. T2W intensities in 231 biopsy ROIs were significantly negatively correlated with GS (rS = -0.21, p = 0.001), Decipher (rS = -0.193, p = 0.003), and three-tier risk (rS = -0.235, p < 0.001). The average T2W intensities in the aggressive ROIs were significantly lower than in the indolent ROIs after normalization. In conclusion, the automated triple-reference tissue normalization method significantly improved the discrimination between prostate cancer and normal prostate tissue. In addition, the normalized T2W intensities of cancer exhibited a significant association with tumor aggressiveness. By improving the quantitative utilization of the T2W in the assessment of prostate cancer on MRI, the new normalization method represents an important advance over clinical protocols that do not include sequences for the measurement of T2 relaxation times.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias da Próstata , Masculino , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Biópsia
6.
NMR Biomed ; : e5172, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38794994

RESUMO

Limb-girdle muscular dystrophy (LGMD) type R1 (LGMDR1) is the most common subtype of LGMD in Europe. Prospective longitudinal data, including clinical assessments and new biomarkers such as quantitative magnetic resonance imaging (qMRI), are needed to evaluate the natural course of the disease and therapeutic options. We evaluated eight thigh and seven leg muscles of 13 LGMDR1 patients (seven females, mean age 36.7 years, body mass index 23.9 kg/m2) and 13 healthy age- and gender-matched controls in a prospective longitudinal design over 1 year. Clinical assessment included testing for muscle strength with quick motor function measure (QMFM), gait analysis and patient questionnaires (neuromuscular symptom score, activity limitation [ACTIVLIM]). MRI scans were performed on a 3-T MRI scanner, including a Dixon-based sequence, T2 mapping and diffusion tensor imaging. The qMRI values of fat fraction (FF), water T2 relaxation time (T2), fractional anisotropy, mean diffusivity, axial diffusivity and radial diffusivity were analysed. Within the clinical outcome measures, significant deterioration between baseline and follow-up was found for ACTIVLIM (p = 0.029), QMFM (p = 0.012). Analysis of qMRI parameters of the patient group revealed differences between time points for both FF and T2 when analysing all muscles (FF: p < 0.001; T2: p = 0.016). The highest increase of fat replacement was found in muscles with an FF of between 10% and 50% at baseline. T2 in muscles with low-fat replacement increased significantly. No significant differences were found for the diffusion metrics. Significant correlations between qMRI metrics and clinical assessments were found at baseline and follow-up, while only T2 changes in thigh muscles correlated with changes in ACTIVLIM over time (ρ = -0.621, p < 0.05). Clinical assessments can show deterioration of the general condition of LGMDR1 patients. qMRI measures can give additional information about underlying pathophysiology. Further research is needed to establish qMRI outcome measures for clinical trials.

7.
NMR Biomed ; : e5240, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39188210

RESUMO

Functional magnetic resonance spectroscopy (fMRS) measures dynamic changes in metabolite concentration in response to neural stimulation. The biophysical basis of these changes remains unclear. One hypothesis suggests that an increase or decrease in the glutamate signal detected by fMRS could be due to neurotransmitter movements between cellular compartments with different T2 relaxation times. Previous studies reporting glutamate (Glu) T2 values have generally sampled at echo times (TEs) within the range of 30-450 ms, which is not adequate to observe a component with short T2 (<20 ms). Here, we acquire MRS measurements for Glu, (t) total creatine (tCr) and total N-acetylaspartate (tNAA) from the visual cortex in 14 healthy participants at a range of TE values between 9.3-280 ms during short blocks (64 s) of flickering checkerboards and rest to examine both the short- and long-T2 components of the curve. We fit monoexponential and biexponential Glu, tCr and tNAA T2 relaxation curves for rest and stimulation and use Akaike information criterion to assess best model fit. We also include power calculations for detection of a 2% shift of Glu between compartments for each TE. Using pooled data over all participants at rest, we observed a short Glu T2-component with T2 = 10 ms and volume fraction of 0.35, a short tCr T2-component with T2 = 26 ms and volume fraction of 0.25 and a short tNAA T2-component around 15 ms with volume fraction of 0.34. No statistically significant change in Glu, tCr and tNAA signal during stimulation was detected at any TE. The volume fractions of short-T2 component between rest and active conditions were not statistically different. This study provides evidence for a short T2-component for Glu, tCr and tNAA but no evidence to support the hypothesis of task-related changes in glutamate distribution between short and long T2 compartments.

8.
NMR Biomed ; 37(5): e5106, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38263738

RESUMO

PURPOSE: Both sodium T1 triple quantum (TQ) signal and T1 relaxation pathways have a unique sensitivity to the sodium molecular environment. In this study an inversion recovery time proportional phase increment (IRTQTPPI) pulse sequence was investigated for simultaneous and reliable quantification of sodium TQ signal and bi-exponential T1 relaxation times. METHODS: The IRTQTPPI sequence combines inversion recovery TQ filtering and time proportional phase increment. The reliable and reproducible results were achieved by the pulse sequence optimized in three ways: (1) optimization of the nonlinear fit for the determination of both T1-TQ signal and T1 relaxation times; (2) suppression of unwanted signals by assessment of four different phase cycles; (3) nonlinear sampling during evolution time for optimal scan time without any compromises in fit accuracy. The relaxation times T1 and T2 and the TQ signals from IRTQTPPI and TQTPPI were compared between 9.4 and 21.1 T. The motional environment of the sodium nuclei was evaluated by calculation of correlation times and nuclear quadrupole interaction strengths. RESULTS: Reliable measurements of the T1-TQ signals and T1 bi-exponential relaxation times were demonstrated. The fit parameters for all four phase cycles were in good agreement with one another, with a negligible influence of unwanted signals. The agar samples yielded normalized T1-TQ signals from 3% to 16% relative to single quantum (SQ) signals at magnetic fields of both 9.4 and 21.1 T. In comparison, the normalized T2-TQ signal was in the range 15%-35%. The TQ/SQ signal ratio was decreased at 21.1 T as compared with 9.4 T for both T1 and T2 relaxation pathways. The bi-exponential T1 relaxation time separation ranged from 15 to 18 ms at 9.4 T and 15 to 21 ms at 21.1 T. The T2 relaxation time separation was larger, ranging from 28 to 35 ms at 9.4 T and 37 to 40 ms at 21.1 T. CONCLUSION: The IRTQTPPI sequence, while providing a less intensive TQ signal than TQTPPI, allows a simultaneous and reliable quantification of both the T1-TQ signal and T1 relaxation times. The unique sensitivities of the T1 and T2 relaxation pathways to different types of molecular motion provide a deeper understanding of the sodium MR environment.


Assuntos
Imageamento por Ressonância Magnética , Sódio , Imageamento por Ressonância Magnética/métodos
9.
J Magn Reson Imaging ; 59(2): 699-710, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37209407

RESUMO

BACKGROUND: Clear cell renal cell carcinoma (ccRCC) is the most common subtype of RCC, and accurate grading is crucial for prognosis and treatment selection. Biopsy is the reference standard for grading, but MRI methods can improve and complement the grading procedure. PURPOSE: Assess the performance of diffusion relaxation correlation spectroscopic imaging (DR-CSI) in grading ccRCC. STUDY TYPE: Prospective. SUBJECTS: 79 patients (age: 58.1 +/- 11.5 years; 55 male) with ccRCC confirmed by histopathology (grade 1, 7; grade 2, 45; grade 3, 18; grade 4, 9) following surgery. FIELD STRENGTH/SEQUENCE: 3.0 T MRI scanner. DR-CSI with a diffusion-weighted echo-planar imaging sequence and T2-mapping with a multi-echo spin echo sequence. ASSESSMENT: DR-CSI results were analyzed for the solid tumor regions of interest using spectrum segmentation with five sub-region volume fraction metrics (VA , VB , VC , VD , and VE ). The regulations for spectrum segmentation were determined based on the D-T2 spectra of distinct macro-components. Tumor size, voxel-wise T2, and apparent diffusion coefficient (ADC) values were obtained. Histopathology assessed tumor grade (G1-G4) for each case. STATISTICAL TESTS: One-way ANOVA or Kruskal-Wallis test, Spearman's correlation (coefficient, rho), multivariable logistic regression analysis, receiver operating characteristic curve analysis, and DeLong's test. Significance criteria: P < 0.05. RESULTS: Significant differences were found in ADC, T2, DR-CSI VB , and VD among the ccRCC grades. Correlations were found for ccRCC grade to tumor size (rho = 0.419), age (rho = 0.253), VB (rho = 0.553) and VD (rho = -0.378). AUC of VB was slightly larger than ADC in distinguishing low-grade (G1-G2) from high-grade (G3-G4) ccRCC (0.801 vs. 0.762, P = 0.406) and G1 from G2 to G4 (0.796 vs. 0.647, P = 0.175), although not significant. Combining VB , VD , and VE had better diagnostic performance than combining ADC and T2 for differentiating G1 from G2-G4 (AUC: 0.814 vs 0.643). DATA CONCLUSION: DR-CSI parameters are correlated with ccRCC grades, and may help to differentiate ccRCC grades. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Estudos Prospectivos , Imageamento por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética/métodos , Gradação de Tumores , Estudos Retrospectivos
10.
Connect Tissue Res ; 65(2): 146-160, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38415672

RESUMO

PURPOSE: Degradation of articular cartilage (AC) due to injury to the knee joint may initiate post-traumatic osteoarthritis (PTOA). Failure to diagnose the onset of the disease at an early stage makes the cure ineffective for PTOA. This study investigated the consequences of a mechanical injury to the knee in a rabbit model using microscopic magnetic resonance imaging (µMRI) at high resolution. MATERIALS AND METHODS: A mechanical injury was induced to the knee joints of 12 rabbits. Cartilage blocks were extracted from the non-impacted and impacted knee joints after 2 and 14 weeks post-impact. The specimens were studied using µMRI T2 relaxation and inductively coupled plasma analysis to determine the early degradation of the articular cartilage. RESULTS: The data established a connection between T2 relaxation time and the early progression of knee PTOA after an impact injury. T2 values were found to be higher in the impacted cartilage at both 2 and 14 weeks, in particular, T2-55° values in the impacted samples displayed a significant rise of 6.93% after 2 weeks and 20.02% after 14 weeks. Lower glycosaminoglycan measurement and higher water content in the impacted cartilage confirmed the µMRI results. CONCLUSIONS: This µMRI T2 study was able to detect cartilage damage in the impacted knees. In addition, greater degradation in the affected knees at 14 weeks than at 2 weeks indicated the progressive nature of cartilage deterioration over time. The µMRI results were in accord with the biochemical analysis, indicating the detection of early structural damage in the cartilage.


Assuntos
Cartilagem Articular , Osteoartrite , Animais , Coelhos , Cartilagem Articular/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Modelos Animais de Doenças
11.
Eur Radiol ; 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39093414

RESUMO

OBJECTIVE: To investigate the value of fat-suppression (FS) T2 relaxation time (T2RT) derived from FS T2 mapping and water fraction (WF) derived from T2 IDEAL to predict the treatment response to intravenous glucocorticoids (IVGC) in patients with thyroid-associated ophthalmopathy (TAO) based on texture analysis. MATERIALS AND METHODS: In this study, 89 patients clinically diagnosed with active and moderate-to-severe TAO were enroled (responsive group, 48 patients; unresponsive group, 41 patients). The baseline clinical characteristics and texture features were compared between the two groups. Multivariate analysis was performed to identify the independent predictors of treatment response to IVGC. ROC analysis and the DeLong test were used to assess and compare the predictive performance of different models. RESULTS: The responsive group exhibited significantly shorter disease duration and higher 90th percentile of FS T2RT and kurtosis of WF in the extraocular muscle (EOM) and 95th percentile of WF in the orbital fat (OF) than the unresponsive group. Model 2 (disease duration + WF; AUC, 0.816) and model 3 (disease duration + FS T2RT + WF; AUC, 0.823) demonstrated superior predictive efficacy compared to model 1 (disease duration + FS T2RT; AUC, 0.756), while there was no significant difference between models 2 and 3. CONCLUSIONS: The orbital tissues of responders exhibited more oedema and heterogeneity. Furthermore, OF is as valuable as EOM for assessing the therapeutic efficacy of IVGC. Finally, WF derived from T2 IDEAL processed by texture analysis can provide valuable information for predicting the treatment response to IVGC in patients with active and moderate-to-severe TAO. CLINICAL RELEVANCE STATEMENT: The texture features of FS T2RT and WF are different between responders and non-responders, which can be the predictive tool for treatment response to IVGC. KEY POINTS: Texture analysis can be used for predicting response to IVGC in TAO patients. TAO patients responsive to IVGC show more oedema and heterogeneity in the orbital tissues. WF from T2 IDEAL is a tool to predict the therapeutic response of TAO.

12.
Cereb Cortex ; 33(7): 3562-3574, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-35945683

RESUMO

Quantitative magnetic resonance (MR) has been used to study cyto- and myelo-architecture of the human brain non-invasively. However, analyzing brain cortex using high-resolution quantitative MR acquisition can be challenging to perform using 3T clinical scanners. MR fingerprinting (MRF) is a highly efficient and clinically feasible quantitative MR technique that simultaneously provides T1 and T2 relaxation maps. Using 3D MRF from 40 healthy subjects (mean age = 25.6 ± 4.3 years) scanned on 3T magnetic resonance imaging, we generated whole-brain gyral-based normative MR relaxation atlases and investigated cortical-region-based T1 and T2 variations. Gender and age dependency of T1 and T2 variations were additionally analyzed. The coefficient of variation of T1 and T2 for each cortical-region was 3.5% and 7.3%, respectively, supporting low variability of MRF measurements across subjects. Significant differences in T1 and T2 were identified among 34 brain regions (P < 0.001), lower in the precentral, postcentral, paracentral lobule, transverse temporal, lateral occipital, and cingulate areas, which contain sensorimotor, auditory, visual, and limbic functions. Significant correlations were identified between age and T1 and T2 values. This study established whole-brain MRF T1 and T2 atlases of healthy subjects using a clinical 3T scanner, which can provide a quantitative and region-specific baseline for future brain studies and pathology detection.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Adulto Jovem , Adulto , Lactente , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Voluntários Saudáveis , Processamento de Imagem Assistida por Computador/métodos
13.
Scand J Med Sci Sports ; 34(9): e14718, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39215390

RESUMO

The aim of the present study was to examine the effects of attentional focus instructions on acute changes in the transverse relaxation time (T2) of the femorotibial cartilage and in cartilage volume during repeated drop-jump landings. Ten healthy females (Mage = 20.4 ± 0.8 years) performed a drop landing task from a 50 cm high box over the course of 3 days (50 repetitions each day) across three attentional focus conditions: external focus (EF: focus on landing as soft as possible), internal focus (IF: focus on bending your knees when you land), and control (CON: no-focus instruction), which was counterbalanced across focus conditions. T2 mapping and the volume of femorotibial cartilage were determined from magnetic resonance imaging scans at 1.5 T for the dominant knee before and after completing the drop landings in each attentional focus condition per day. Results indicated a smaller change in cartilage T2 relaxation time and volumetry in the central load-bearing lateral cartilage under the EF, compared to IF and CON. Moreover, the change in T2 and cartilage volume was greater for lateral tibial cartilage as compared to femoral cartilage and was independent of attentional focus instructions. No significant acute quantitative changes were observed in the medial compartment. The peak vertical ground reaction force was found to be the lowest under the EF, compared to IF and CON. These findings suggest that external focus of attention may reduce cartilage load, potentially aiding in the control or management of cartilage injuries during landing in female athletes.


Assuntos
Atenção , Cartilagem Articular , Imageamento por Ressonância Magnética , Suporte de Carga , Humanos , Feminino , Cartilagem Articular/fisiologia , Cartilagem Articular/diagnóstico por imagem , Atenção/fisiologia , Adulto Jovem , Suporte de Carga/fisiologia , Fenômenos Biomecânicos , Articulação do Joelho/fisiologia , Exercício Pliométrico , Tíbia/fisiologia , Tíbia/diagnóstico por imagem
14.
Hippocampus ; 33(11): 1189-1196, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37587770

RESUMO

Mesial temporal lobe epilepsy is one of the most common causes of refractory epilepsy worldwide. A good percentage of patients do not have detectable hippocampal atrophy on magnetic resonance imaging (MRI). The objective of this study is to evaluate whether T2 relaxometry can identify hippocampal pathology and lateralize the epileptic focus in patients with intractable temporal lobe epilepsy (TLE). T2 relaxometry can also be used to correlate the clinical severity of the disease with the relaxometry readings in those who have hippocampal atrophy as well as those who do not. Thirty two patients having clinical and electrophysiological features of TLE were enrolled and a MRI brain with T2 relaxometry was done. Hippocampal T2 relaxometry values were calculated in the head, body, and tail of the hippocampus and average T2 relaxometry values were calculated, and a comparison was done with the controls. For patients with unilateral involvement, the contralateral side was taken as control and in cases of bilateral involvement, controls were identified from normal subjects. T2 relaxometry is found to be superior to MR visual analysis in the early detection of cases of hippocampal sclerosis where there is no atrophy on visual analysis. Nine out of 32 patients (28%) were normal on MR visual analysis; however, showed increased values on T2 relaxometry, correlating with clinical and electrophysiological diagnosis. The rest of the patients with hippocampal atrophy showed a correlation of T2 relaxometry values with the degree of atrophy. The hippocampal T2 measurement is thus more sensitive and specific. The study was clinically significant (p < .0001). There was a mild female predilection of the disease and there was no significant correlation with comorbidities. There was a strong positive correlation with patients having a history of febrile seizures in childhood. T2 relaxometry may accurately lateralize the majority of patients with persistent TLE and offers evidence of hippocampus injury in those patients who do not show evidence of atrophy on MRI and also the T2 relaxometry values correlated with the degree of atrophy. Early identification of hippocampal sclerosis is crucial for prompt management which offers better outcomes.


Assuntos
Epilepsia do Lobo Temporal , Esclerose Hipocampal , Doenças Neurodegenerativas , Humanos , Feminino , Epilepsia do Lobo Temporal/diagnóstico por imagem , Epilepsia do Lobo Temporal/patologia , Estudos Transversais , Hipocampo/diagnóstico por imagem , Hipocampo/patologia , Imageamento por Ressonância Magnética/métodos , Doenças Neurodegenerativas/patologia , Atrofia , Esclerose/diagnóstico por imagem , Esclerose/patologia
15.
Magn Reson Med ; 90(1): 211-221, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36880522

RESUMO

PURPOSE: Asymmetric spin echo (ASE) MRI is a method for measuring regional oxygen extraction fraction (OEF); however, extravascular tissue models have been shown to under-estimate OEF. The hypothesis investigated here is that the addition of a vascular-space-occupancy (VASO) pre-pulse will more fully suppress blood water signal and provide global OEF values more consistent with physiological expectation and 15 O positron emission tomography (PET)-validated T2 -relaxation-under-spin-tagging (TRUST) OEF measures. METHODS: Healthy adults (n = 14; age = 27.7 ± 5.2 y; sex = 7/7 male/female) were scanned at 3.0T. Multi-echo ASE without inter-readout refocusing (ASERF- ), multi-echo ASE with inter-readout refocusing (ASERF+ ), and single-echo VASO-ASE were acquired twice each with common spatial resolution = 3.44 × 3.44 × 3.0 mm and τ = 0-20 ms (interval = 0.5 ms). TRUST was acquired twice sequentially for independent global OEF assessment (τCPMG  = 10 ms; effective TEs = 0, 40, 80, and 160 ms; spatial resolution = 3.4 × 3.4 × 5 mm). OEF intraclass-correlation-coefficients (ICC), summary statistics, and group-wise differences were assessed (Wilcoxon rank-sum; significance: two-sided p < 0.05). RESULTS: ASERF+ (OEF = 36.8 ± 1.9%) and VASO-ASE (OEF = 34.4 ± 2.3%) produced OEF values similar to TRUST (OEF = 36.5 ± 4.6%, human calibration model; OEF = 32.7 ± 4.9%, bovine calibration model); however, ASERF- yielded lower OEF (OEF = 26.1 ± 1.0%; p < 0.01) relative to TRUST. VASO-ASE (ICC = 0.61) yielded lower ICC compared to other ASE variants (ICC >0.89). CONCLUSION: VASO-ASE and TRUST provide similar OEF values; however, VASO-ASE spatial coverage and repeatability improvements are required.


Assuntos
Imageamento por Ressonância Magnética , Oxigênio , Adulto , Humanos , Masculino , Feminino , Animais , Bovinos , Adulto Jovem , Imageamento por Ressonância Magnética/métodos , Frequência Cardíaca , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Circulação Cerebrovascular , Consumo de Oxigênio
16.
Osteoarthritis Cartilage ; 31(1): 96-105, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36252943

RESUMO

OBJECTIVE: Evaluate patellofemoral cartilage health, as assessed by quantitative magnetic resonance imaging (qMRI) T2 relaxation times, 24-months after ACL reconstruction (ACLR) and determine if they were associated with patellofemoral contact forces and knee mechanics during gait 3 months after surgery. DESIGN: Thirty individuals completed motion analysis during overground walking at a self-selected speed 3 months after ACLR. An EMG-driven neuromusculoskeletal model was used to determine muscle forces, which were then used in a previously described model to estimate patellofemoral contact forces. Biomechanical variables of interest included peak patellofemoral contact force, peak knee flexion angle and moment, and walking speed. These same participants underwent a sagittal bilateral T2 mapping qMRI scan 24-months after surgery. T2 relaxation times were estimated for both patellar and trochlear cartilage. Paired t-tests were used to compare T2 relaxation times between limbs while Pearson correlations and linear regressions were utilized to assess the association between the biomechanical variables of interest and T2 relaxation times. RESULTS: Prolonged involved limb trochlear T2 relaxation times (vs uninvolved) were present 24-months after surgery, indicating worse cartilage health. No differences were detected in patellar cartilage. Significant negative associations were present within the involved limb for all the biomechanical variables of interest 3 months after ACLR and trochlear T2 relaxation times at 24-months. No associations were found in patellar cartilage or within the uninvolved limb. CONCLUSIONS: Altered involved limb trochlear cartilage health is present 24-months after ACLR and may be related to patellofemoral loading and other walking gait mechanics 3 months after surgery.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Cartilagem Articular , Osteoartrite do Joelho , Humanos , Reconstrução do Ligamento Cruzado Anterior/métodos , Cartilagem Articular/patologia , Osteoartrite do Joelho/patologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Marcha/fisiologia , Lesões do Ligamento Cruzado Anterior/cirurgia , Imageamento por Ressonância Magnética/métodos , Fenômenos Biomecânicos
17.
NMR Biomed ; 36(12): e5016, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37587062

RESUMO

The purpose of the current study was to develop a novel single-voxel MR spectroscopy acquisition scheme to simultaneously determine metabolite-specific concentrations and transverse relaxation times within realistic clinical scan times. Partly truncated multi-TE data are acquired as an echo train in a single acquisition (multi-echo single-shot [MESS]). A 2D multiparametric model fitting approach combines truncated, low-resolved short TE data with fully sampled, highly resolved, longer TE data to yield concentration and T2 estimates for major brain metabolites simultaneously. Cramer-Rao lower bounds (CRLB) are used as a measure of performance. The novel scheme was compared with traditional multi-echo multi-shot methods. In silico, in vitro, and in vivo experiments support the findings. MESS schemes, requiring only 2 min 12 s for the acquisition of three echo times, provide valid concentration and relaxation estimates for multiple metabolites and outperform traditional methods for simultaneous determinations of metabolite-specific T2 s and concentrations, with improvements ranging from 5% to 30% for T2 s and from 10% to 50% for concentrations. However, substantial unsuppressed residual water signals may hamper the method's reproducibility, as observed in an initial experiment setup that prioritizes short TEs with severely truncated acquisition for the benefit of signal-to-noise ratio (SNR). Nevertheless, CRLB have been confirmed to be well suited as design criteria, and within-session repeatability approaches CRLB when residual water is removed in postprocessing by exploiting longer and less truncated data recordings. MESS MRS combined with 2D model fitting promises comparable accuracy, increased precision, or inversely shorter experimental times compared with traditional approaches. However, the optimal design must be investigated as a trade-off between SNR, the truncation factor, and TE batch selections, all of which influence the robustness of estimations.


Assuntos
Encéfalo , Água , Reprodutibilidade dos Testes , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Razão Sinal-Ruído , Água/metabolismo
18.
J Magn Reson Imaging ; 58(6): 1954-1963, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37026419

RESUMO

BACKGROUND: Preventing sepsis-associated acute kidney injury (S-AKI) can be challenging because it develops rapidly and is often asymptomatic. Probability assessment of disease progression for therapeutic follow-up and outcome are important to intervene and prevent further damage. PURPOSE: To establish a noninvasive multiparametric MRI (mpMRI) tool, including T1 , T2 , and perfusion mapping, for probability assessment of the outcome of S-AKI. STUDY TYPE: Preclinical randomized prospective study. ANIMAL MODEL: One hundred and forty adult female SD rats (65 control and 75 sepsis). FIELD STRENGTH/SEQUENCE: 9.4T; T1 and perfusion map (FAIR-EPI) and T2 map (multiecho RARE). ASSESSMENT: Experiment 1: To identify renal injury in relation to sepsis severity, serum creatinine levels were determined (31 control and 35 sepsis). Experiment 2: Animals underwent mpMRI (T1 , T2 , perfusion) 18 hours postsepsis. A subgroup of animals was immediately sacrificed for histology examination (nine control and seven sepsis). Result of mpMRI in follow-up subgroup (25 control and 33 sepsis) was used to predict survival outcomes at 96 hours. STATISTICAL TESTS: Mann-Whitney U test, Spearman/Pearson correlation (r), P < 0.05 was considered statistically significant. RESULTS: Severely ill septic animals exhibited significantly increased serum creatinine levels compared to controls (70 ± 30 vs. 34 ± 9 µmol/L, P < 0.0001). Cortical perfusion (480 ± 80 vs. 330 ± 140 mL/100 g tissue/min, P < 0.005), and cortical and medullary T2 relaxation time constants were significantly reduced compared to controls (41 ± 4 vs. 37 ± 5 msec in cortex, P < 0.05, 52 ± 7 vs. 45 ± 6 msec in medulla, P < 0.05). The combination of cortical T2 relaxation time constants and perfusion results at 18 hours could predict survival outcomes at 96 hours with high sensitivity (80%) and specificity (73%) (area under curve of ROC = 0.8, Jmax = 0.52). DATA CONCLUSION: This preclinical study suggests combined T2 relaxation time and perfusion mapping as first line diagnostic tool for treatment planning. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Injúria Renal Aguda , Sepse , Feminino , Ratos , Animais , Estudos Prospectivos , Creatinina , Ratos Sprague-Dawley , Injúria Renal Aguda/diagnóstico por imagem , Injúria Renal Aguda/patologia , Imageamento por Ressonância Magnética , Perfusão , Sepse/complicações , Sepse/diagnóstico por imagem
19.
J Magn Reson Imaging ; 57(6): 1805-1812, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36190187

RESUMO

BACKGROUND: Magnetic resonance fingerprinting (MRF) techniques have been recently described for simultaneous multiparameter cartilage mapping of the knee although investigation of their ability to detect early cartilage degeneration remains limited. PURPOSE: To investigate age-dependent changes in knee cartilage T1 , T2 , and T1p relaxation times measured using a three-dimensional (3D) MRF sequence in healthy volunteers. STUDY TYPE: Prospective. SUBJECTS: The study group consisted of 24 healthy asymptomatic human volunteers (15 males with mean age 34.9 ± 14.4 years and 9 females with mean age 44.5 ± 13.1 years). FIELD STRENGTH/SEQUENCE: A 3.0 T gradient-echo-based 3D-MRF sequence was used to simultaneously create proton density-weighted images and T1 , T2 , and T1p maps of knee cartilage. ASSESSMENT: Mean global cartilage and regional cartilage (lateral femur, lateral tibia, medial femur, medial tibia, and patella) T1 , T2 , and T1ρ relaxation times of the knee were measured. STATISTICAL TESTS: Kruskal-Wallis tests were used to compared cartilage T1 , T2 , and T1ρ relaxation times between different age groups, while Spearman correlation coefficients was used to determine the association between age and cartilage T1 , T2 , and T1ρ relaxation times. The value of P < 0.05 was considered statistically significant. RESULTS: Higher age groups showed higher global and regional cartilage T1 , T2 , and T1ρ . There was a significant difference between age groups in global cartilage T2 and T1ρ but no significant difference (P = 0.13) in global cartilage T1. Significant difference was also present between age groups in cartilage T2 and T1ρ for medial femur cartilage and medial tibia cartilage. There were significant moderate correlations between age and T2 and T1ρ for global cartilage (R2  = 0.63-0.64), medial femur cartilage (R2  = 0.50-0.56), and medial tibia cartilage (R2  = 0.54-0.66). CONCLUSION: Cartilage T2 and T1p relaxation times simultaneously measured using a 3D-MRF sequence in healthy volunteers showed age-dependent changes in knee cartilage, primarily within the medial compartment.


Assuntos
Cartilagem Articular , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Estudos Prospectivos , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Joelho , Imageamento por Ressonância Magnética/métodos
20.
J Magn Reson Imaging ; 58(5): 1557-1568, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36877200

RESUMO

BACKGROUND: The reference standard for assessing water T2 (T2,H2O ) at high fat fraction (FF) is 1 H MRS. T2,H2O (T2,H2O,MRS ) dependence on FF (FFMRS ) has recently been demonstrated in muscle at high FF (i.e. ≥60%). PURPOSE: To investigate the relationship between T2,H2O,MRS and FFMRS in the thigh/leg muscles of patients with neuromuscular diseases and to compare with quantitative MRI. STUDY TYPE: Retrospective case-control study. POPULATION: A total of 151 patients with neuromuscular disorders (mean age ± standard deviation = 52.5 ± 22.6 years, 54% male), 44 healthy volunteers (26.5 ± 13.0 years, 57% male). FIELD STRENGTH/SEQUENCE: A 3-T; single-voxel stimulated echo acquisition mode (STEAM) MRS, multispin echo (MSE) imaging (for T2 mapping, T2,H2O,MRI ), three-point Dixon imaging (for FFMRI and R 2 * mapping). ASSESSMENT: Mono-exponential and bi-exponential models were fitted to water T2 decay curves to extract T2,H2O,MRS and FFMRS . Water resonance full-width-at-half-maximum (FWHM) and B0 spread (∆B0 ) values were calculated. T2,H2O,MRI (mean), FFMRI (mean, kurtosis, and skewness), and R 2 * (mean) values were estimated in the MRS voxel. STATISTICAL TESTS: Mann-Whitney U tests, Kruskal-Wallis tests. A P-value <0.05 was considered statistically significant. RESULTS: Normal T2,H2O,MRS threshold was defined as the 90th percentile in healthy controls: 30.3 msec. T2,H2O,MRS was significantly higher in all patients with FFMRS < 60% compared to healthy controls. We discovered two subgroups in patients with FFMRS ≥ 60%: one with T2,H2O,MRS ≥ 30.3 msec and one with T2,H2O,MRS < 30.3 msec including abnormally low T2,H2O,MRS . The latter subgroup had significantly higher water resonance FWHM, ∆B0 , FFMRI kurtosis, and skewness values but nonsignificantly different R 2 * (P = 1.00) and long T2,H2O,MRS component and its fraction (P > 0.11) based on the bi-exponential analysis. DATA CONCLUSION: The findings suggest that the cause for (abnormally) T2,H2O,MRS at high FFMRS is biophysical, due to differences in susceptibility between muscle and fat (increased FWHM and ∆B0 ), rather than pathophysiological such as compartmentation changes, which would be reflected by the bi-exponential analysis. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 3.


Assuntos
Doenças Neuromusculares , Água , Humanos , Masculino , Feminino , Estudos Retrospectivos , Estudos de Casos e Controles , Músculo Esquelético/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa