Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Sensors (Basel) ; 24(4)2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38400450

RESUMO

A meta-surface-based arbitrary bandwidth filter realization method for terahertz (THz) future communications is presented. The approach involves integrating a meta-surface-based bandstop filter into an ultra-wideband (UWB) bandpass filter and adjusting the operating frequency range of the meta-surface bandstop filter to realize the design of arbitrary bandwidth filters. It effectively addresses the complexity of designing traditional arbitrary bandwidth filters and the challenges in achieving impedance matching. To underscore its practicality, the paper employs silicon substrate integrated gap waveguide (SSIGW) and this method to craft a THz filter. To begin, design equations for electromagnetic band gap (EBG) structures were developed in accordance with the requirements of through-silicon via (TSV) and applied to the design of the SSIGW. Subsequently, this article employs equivalent transmission line models and equivalent circuits to conduct theoretical analyses for both the UWB passband and the meta-surface stopband portions. The proposed THz filter boasts a center frequency of 0.151 THz, a relative bandwidth of 6.9%, insertion loss below 0.68 dB, and stopbands exceeding 20 GHz in both upper and lower ranges. The in-band group delay is 0.119 ± 0.048 ns. Compared to reported THz filters, the SSIGW filter boasts advantages such as low loss and minimal delay, making it even more suitable for future wireless communication.

2.
Int Wound J ; 21(4): e14611, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38156741

RESUMO

The utilization of 27-G TSV, or 27-Gauge Transconjunctival Sutureless Vitrectomy, poses distinct difficulties in the context of paediatric patients, particularly those younger than 14 years old, on account of the dearth of exhaustive documentation concerning the efficacy and results of these operations. Therefore, this retrospective study was to evaluate the safety and efficacy of 27-G TSV in paediatric patients, with emphasis on management of intraoperative and postoperative complications and postoperative wound healing. A total of 54 eyes of 52 paediatric patients who underwent 27-G TSV at Sichuan Provincial People's Hospital were included in the study. The average duration of follow-up was 9.32 ± 3.35 months. The complication with the highest incidence rate was Rhegmatogenous Retinal Detachment (RRD), which was detected in 27.8% cases. Familial Exudative Vitreoretinopathy (FEVR) and Persistent Fetal Vasculature (PFV) each accounted for 16.7% of the cases. Retinopathy of Prematurity (ROP) and Vitreous Haemorrhage (VH) constituted 11.1% and 14.8%, respectively, of the reported cases. Lens injury (1.9%), cannula slippage (7.4%) and wound leakage (5.6%) were intraoperative complications. Iatrogenic retinal detachment occurred at 3.7%. Hypotony (10.8% of patients), vitreous haemorrhage (9.3%), cataract formation (9.3%), ocular hypertension (8.1%) and retinal detachment (5.6%) were postoperative complications. Effective management strategies were executed, such as performing in situ trocar puncture to address cannula slippage and promptly suturing to address wound leakage. 27-G TSV exhibited promise as the therapeutic alternative for range of vitreoretinal disorders in paediatric patients, accompanied by complications that were controllable during and after the procedure. Strict preoperative planning and precise surgical technique are indispensable in order to maximize patient outcomes and guarantee effective wound healing and recovery within this particular demographic.


Assuntos
Descolamento Retiniano , Recém-Nascido , Humanos , Criança , Adolescente , Descolamento Retiniano/cirurgia , Vitrectomia/métodos , Hemorragia Vítrea/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Técnicas de Sutura , Cicatrização
3.
Build Environ ; 229: 109893, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36514557

RESUMO

The COVID-19 pandemic has significantly changed people's lifestyles, and wearing surgical masks in outdoor public spaces has become commonplace. However, few studies have explored the impact of wearing masks on outdoor thermal comfort in different seasons. From May 2021 to February 2022, a series of longitudinal experiments were conducted in Xiamen, China to examine the effect of wearing surgical masks on outdoor thermal comfort. Forty-two participants took part in the experiments with and without masks. During the experiments, the thermal perceptions of the subjects and environmental thermal parameters were collected. Differences in outdoor thermal comfort between subjects wearing masks and those not wearing masks were determined in summer, autumn, and winter. Results showed that 1) the subjects wearing masks had lower neutral temperatures, and this difference was particularly pronounced in summer and exacerbated by walking; 2) in warm environments, masks reduced thermal comfort, and discomfort associated with masks was worse when walking than when sitting; 3) wearing masks significantly worsened facial comfort and increased chest discomfort, as summer turned to winter, the impact of masks on facial comfort decreased; 4) radiation and air temperature were the environmental parameters with the greatest impact on outdoor thermal sensation. Subjects who wore masks preferred lower temperatures, radiation, and humidity, and higher wind speeds.

4.
Sensors (Basel) ; 22(6)2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35336284

RESUMO

The development of 5G mobile communication created the need for high-frequency communication systems, which require vast quantities of radio frequency (RF) filters with a high-quality factor (Q) and low inband losses. In this study, the packaging of an RF filter with a through-glass via (TGV) interposer was designed and fabricated using a three-dimensional wafer-level package (3D WLP). TGV fabrication is a high-yielding process, which can produce high precision vias without masking and lithography and reduce the manufacturing cost compared with the through silicon via (TSV) solution. The glass interposer capping wafer contains Cu-filled TGV, a metal redistribution layer (RDL), and the bonding layer. The RF filter substrate with Au bump is bonded to the capping wafer based on Au-Sn transient liquid phase (TLP) bonding at 280 °C with a 40 kN (approximately 6.5 MPa) bonding force. Experimental results show that shear strengths of approx. 54.5 MPa can be obtained, higher than the standard requirement (~6 MPa). In addition, a comparison of the electrical performance of the RF filter package after the pre-conditional level three (Pre-Con L3) and unbiased highly accelerated stress (uHAST) tests showed no difference in insertion attenuation across the passband (<0.2 dB, standard value: <1 dB). The final packages passed the reliability tests in the field of consumer electronics. The proposed RF filter WLP achieves high performance, low cost, and superior reliability.

5.
Build Environ ; 214: 108932, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35221454

RESUMO

Wearing masks to study and work places has become a daily protective measure during the COVID-19 pandemic. In the summer of 2021, environmental parameters were monitored, and students in a university library in Guangzhou, China, were surveyed to analyze the possible symptoms of wearing masks for a long time, and to assess the sensitivity of various body parts to the environmental parameters. Concurrently, the preference of subjects wearing masks for various environmental parameters was also analyzed. Additionally, the relationship between thermal sensation and thermal index was analyzed to identify acceptable and comfortable temperature ranges. The expected duration of wearing masks was counted. Subjects wearing masks had greater requirements for environmental comfort, and reported increased thermal discomfort of the face and head, compared to those without masks. More than 70% of the subjects wearing masks reported that they experienced discomfort on their faces. Among the subjects who experienced discomfort, 62.7% reported that facial fever was the main symptom; while some reported symptoms of dyspnea (25.4%) and rapid heartbeat (9.1%). More than 75% of the subjects were expected to wear masks for 2.0 h or less. Evaluation of environmental thermal sensation, including overall, facial, and head thermal sensation, differed among subjects who wore and did not wear masks. The indexes of neutral Operative temperature/Standard Effective Temperature (T op /SET*) and preferred T op /SET* were lower among subjects with masks than among those without masks. The neutral T op /SET* deviation was 0.3 °C, and the preferred T op /SET* deviation was 0.5 °C. Additionally, the acceptable and comfortable temperature zones differed between the two cases. The subjects who wore masks preferred colder temperatures. These findings indicated that the environmental parameters should be adjusted to improve the thermal comfort of the human body while wearing masks in work or study places.

6.
J Synchrotron Radiat ; 27(Pt 4): 1023-1032, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33566012

RESUMO

Comprehensive evaluation of through-silicon via (TSV) reliability often requires deterministic and 3D descriptions of local morphological and statistical features of via formation with the Bosch process. Here, a highly sensitive phase-contrast X-ray microtomography approach is presented based on recorrection of abnormal projections, which provides comprehensive and quantitative characterization of TSV etching performance. The key idea is to replace the abnormal projections at specific angles in principles of linear interpolation of neighboring projections, and to distinguish the interface between silicon and air by using phase-retrieval algorithms. It is demonstrated that such a scheme achieves high accuracy in obtaining the etch profile based on the 3D microstructure of the vias, including diameter, bottom curvature radius, depth and sidewall angle. More importantly, the 3D profile error of the via sidewall and the consistency of parameters among all the vias are achieved and analyzed statistically. The datasets in the results and the 3D microstructure can be applied directly to a reference and model for further finite element analysis. This method is general and has potentially broad applications in 3D integrated circuits.

7.
Int J Biometeorol ; 64(2): 187-203, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30209615

RESUMO

A thermal comfort questionnaire survey was carried out in the high-density, tropical city Dhaka. Comfort responses from over 1300 subjects were collected at six different sites, alongside meteorological parameters. The effect of personal and psychological parameters was examined in order to develop predictive models. Personal parameters included gender, age, activity, profession-type (indoor or outdoor-based), exposure to air-conditioned space and sweat-levels. Psychological parameters, such as 'the reason for visiting the place' and 'next destination is air-conditioned', had statistically significant effects on thermal sensation. Other parameters, such as 'body type', 'body exposure to sun', 'time living in Dhaka', 'travelling in last_30 min', and 'hot food' did not have any significant impact. Respondents' humidity, wind speed and solar radiation sensation had profound impacts and people were found willing to adjust to the thermal situations with adaptive behaviour. Based on actual sensation votes from the survey, empirical models are developed to predict outdoor thermal sensation in the case study areas. Ordinal linear regression techniques are applied for predicting thermal sensation by considering meteorological and personal conditions of the field survey. The inclusion of personal and weather opinion factors produced an improvement in models based on meteorological factors. The models were compared with the actual thermal sensation using the cross-tabulation technique. The predictivity of the three models (meteorological, thermos-physiological and combined parameter) as expressed by the gamma coefficient were 0.575, 0.636 and 0.727, respectively. In all three models, better predictability was observed in the 'Slightly Warm' (71% in meteorological model) and 'Hot' (64.9% in combined parameter model) categories-the most important ones in a hot-humid climate.


Assuntos
Microclima , Sensação Térmica , Bangladesh , Cidades , Humanos , Umidade
8.
Sensors (Basel) ; 20(15)2020 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-32707858

RESUMO

To meet the urgent market demand for small package size and high reliability performance for automotive CMOS image sensor (CIS) application, wafer level chip scale packaging (WLCSP) technology using through silicon vias (TSV) needs to be developed to replace current chip on board (COB) packages. In this paper, a WLCSP with the size of 5.82 mm × 5.22 mm and thickness of 850 µm was developed for the backside illumination (BSI) CIS chip using a 65 nm node with a size of 5.8 mm × 5.2 mm. The packaged product has 1392 × 976 pixels and a resolution of up to 60 frames per second with more than 120 dB dynamic range. The structure of the 3D package was designed and the key fabrication processes on a 12" inch wafer were investigated. More than 98% yield and excellent optical performance of the CIS package was achieved after process optimization. The final packages were qualified by AEC-Q100 Grade 2.

9.
Int J Health Geogr ; 18(1): 18, 2019 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-31345233

RESUMO

BACKGROUND: Neighbourhood environment characteristics have been found to be associated with residents' willingness to conduct physical activity (PA). Traditional methods to assess perceived neighbourhood environment characteristics are often subjective, costly, and time-consuming, and can be applied only on a small scale. Recent developments in deep learning algorithms and the recent availability of street view images enable researchers to assess multiple aspects of neighbourhood environment perceptions more efficiently on a large scale. This study aims to examine the relationship between each of six neighbourhood environment perceptual indicators-namely, wealthy, safe, lively, depressing, boring and beautiful-and residents' time spent on PA in Guangzhou, China. METHODS: A human-machine adversarial scoring system was developed to predict perceptions of neighbourhood environments based on Tencent Street View imagery and deep learning techniques. Image segmentation was conducted using a fully convolutional neural network (FCN-8s) and annotated ADE20k data. A human-machine adversarial scoring system was constructed based on a random forest model and image ratings by 30 volunteers. Multilevel linear regressions were used to examine the association between each of the six indicators and time spent on PA among 808 residents living in 35 neighbourhoods. RESULTS: Total PA time was positively associated with the scores for "safe" [Coef. = 1.495, SE = 0.558], "lively" [1.635, 0.789] and "beautiful" [1.009, 0.404]. It was negatively associated with the scores for "depressing" [- 1.232, 0.588] and "boring" [- 1.227, 0.603]. No significant linkage was found between total PA time and the "wealthy" score. PA was further categorised into three intensity levels. More neighbourhood perceptual indicators were associated with higher intensity PA. The scores for "safe" and "depressing" were significantly related to all three intensity levels of PA. CONCLUSIONS: People living in perceived safe, lively and beautiful neighbourhoods were more likely to engage in PA, and people living in perceived boring and depressing neighbourhoods were less likely to engage in PA. Additionally, the relationship between neighbourhood perception and PA varies across different PA intensity levels. A combination of Tencent Street View imagery and deep learning techniques provides an accurate tool to automatically assess neighbourhood environment exposure for Chinese large cities.


Assuntos
Aprendizado Profundo , Exercício Físico/fisiologia , Exercício Físico/psicologia , Características de Residência , Caminhada/fisiologia , Caminhada/psicologia , Adulto , China/epidemiologia , Cidades/epidemiologia , Aprendizado Profundo/tendências , Planejamento Ambiental/tendências , Feminino , Humanos , Masculino , Distribuição Aleatória , Caminhada/tendências
10.
Adv Exp Med Biol ; 1137: 1-8, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31183816

RESUMO

Health and Life studies are well known for the huge amount of data they produce, such as high-throughput sequencing projects (Stephens et al., PLoS Biol 13(7):e1002195, 2015; Hey et al., The fourth paradigm: data-intensive scientific discovery, vol 1. Microsoft research Redmond, Redmond, 2009). However, the value of the data should not be measured by its amount, but instead by the possibility and ability of researchers to retrieve and process it (Leonelli, Data-centric biology: a philosophical study. University of Chicago Press, Chicago, 2016). Transparency, openness, and reproducibility are key aspects to boost the discovery of novel insights into how living systems work (Nosek et al., Science 348(6242):1422-1425, 2015).


Assuntos
Biologia Computacional , Análise de Dados , Sequenciamento de Nucleotídeos em Larga Escala , Reprodutibilidade dos Testes
11.
Int Ophthalmol ; 38(6): 2295-2301, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28980165

RESUMO

PURPOSE: To compare the outcome of 23-gauge as compared with 25-gauge transconjunctival sutureless vitrectomy (TSV) in the management of dislocated intraocular lenses (IOLs). DESIGN: Retrospective, non-consecutive, comparative, interventional case series. PARTICIPANTS: Patients with dislocated intraocular lens who underwent sutureless PPV using either 23-gauge or 25-gauge instruments. METHODS: The patients who presented with a dislocated IOL, underwent TSV with repositioning of the intraocular lens, either in the sulcus or scleral-fixated sutured/glued. RESULTS: Of the total 61 eyes, 33 (54.09%) underwent 23-gauge TSV and 28 (45.90%) underwent 25-gauge TSV. The mean logMAR BCVA at baseline and 6 months after surgery was 0.8 and 0.46 in the 23-gauge group, and 0.82 and 0.47 in the 25-gauge group. There was no significant difference in logMAR BCVA values between the two groups at any time point of time during the follow-up. The mean postoperative IOP on postoperative day 1 was 14.76 ± 5.4 in 23-gauge group and 17.57 ± 7.9 in the 25-gauge group (p = 0.10). Retinal break was noticed intraoperatively in two cases in 23-gauge group and in three cases in 25-gauge group (p = 0.509). Postoperative complications included IOL decentration in one case of 23-gauge vitrectomy and two cases in 25-gauge group (p = 0.5), cystoid macular edema in four patients in 23-gauge group and six cases of 25-gauge group (p = 0.3) and retinal detachment in one case in each group (p = 0.9). CONCLUSIONS: 25-gauge appears to be as safe and as effective as 23-gauge TSV in the management of dislocated intraocular lenses.


Assuntos
Migração do Implante de Lente Intraocular/cirurgia , Túnica Conjuntiva/cirurgia , Técnicas de Sutura , Vitrectomia/métodos , Idoso , Migração do Implante de Lente Intraocular/fisiopatologia , Feminino , Humanos , Pressão Intraocular/fisiologia , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Pseudofacia/fisiopatologia , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia
12.
New Phytol ; 215(1): 240-255, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28248438

RESUMO

Rice is vulnerable to cold stress. Seedlings are very sensitive to cold stress and this harms global rice production. The effects of cold on chloroplast development are well known, but little is known about the underlying molecular mechanisms. Here, we isolated a temperature-sensitive virescent (tsv) mutant that is extremely sensitive to cold stress. It displayed defective chloroplasts, decreased chlorophyll and zero survivorship under cold stress. We isolated and identified TSV by map-based cloning and rescue experiments, combined with genetic, cytological and molecular biological analyses. We found that TSV, a putative plastidic oxidoreductase, is a new type of virescent protein. A mutation in tsv causes premature termination of the gene product. The activity of plastid-encoded RNA polymerase (PEP) and the expression of genes participating in chlorophyll synthesis were severely reduced in the tsv mutant under cold stress, but not at normal temperatures. TSV expression was induced by low temperatures. Strikingly, TSV interacted with OsTrxZ (a subunit of PEP in chloroplasts) and enhanced OsTrxZ stability under low temperatures. We demonstrated that TSV protects rice chloroplasts from cold stress by interacting with OsTrxZ. These results provide novel insights into ways in which rice chloroplast development and chlorophyll synthesis are protected by TSV under cold stress.


Assuntos
Tiorredoxinas de Cloroplastos/metabolismo , Resposta ao Choque Frio , Oryza/fisiologia , Proteínas de Plantas/metabolismo , Clorofila/metabolismo , Cloroplastos/metabolismo , Cloroplastos/fisiologia , Cloroplastos/ultraestrutura , Clonagem Molecular , Análise Mutacional de DNA , Oryza/metabolismo , Oryza/ultraestrutura , Temperatura
13.
Sensors (Basel) ; 17(2)2017 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-28208758

RESUMO

Reliability risks for two different types of through-silicon-vias (TSVs) are discussed in this paper. The first is a partially-filled copper TSV, if which the copper layer covers the side walls and bottom. A polymer is used to fill the rest of the cavity. Stresses in risk sites are studied and ranked for this TSV structure by FEA modeling. Parametric studies for material properties (modulus and thermal expansion) of TSV polymer are performed. The second type is a high aspect ratio TSV filled by polycrystalline silicon (poly Si). Potential risks of the voids in the poly Si due to filling defects are studied. Fracture mechanics methods are utilized to evaluate the risk for two different assembly conditions: package assembled to printed circuit board (PCB) and package assembled to flexible substrate. The effect of board/substrate/die thickness and the size and location of the void are discussed.

14.
J Microsc ; 256(2): 90-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25131954

RESUMO

Total variation minimization is applied to the particular case of X-ray tomography in a scanning electron microscope. To prove the efficiency of this reconstruction method, noise-free and noisy data based on the Shepp & Logan phantom have been simulated. These simulations confirm that Total variation minimization-reconstruction algorithm better manages data containing low number of projections with respect to simultaneous iterative reconstruction technique or filtered backprojection, even in the presence of noise. The algorithm has been applied to real data sets, with a low angular sampling and a high level of noise. Two samples containing micro-interconnections have been analyzed and 3D reconstructions show that Total variation minimization-based algorithm performs well even with 60 projections in order to properly recover a 500 nm diameter void inside a copper interconnection.

15.
Micromachines (Basel) ; 15(4)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38675234

RESUMO

With the advancement of Moore's Law reaching its limits, advanced packaging technologies represented by Flip Chip (FC), Wafer-Level Packaging (WLP), System in Package (SiP), and 3D packaging have received significant attention. While advanced packaging has made breakthroughs in achieving high performance, miniaturization, and low cost, the smaller thermal space and higher power density have created complex physical fields such as electricity, heat, and stress. The packaging interconnects responsible for electrical transmission are prone to serious reliability issues, leading to the device's failure. Therefore, conducting multi-field coupling research on the reliability of advanced packaging interconnects is necessary. The development of packaging and the characteristics of advanced packaging are reviewed. The reliability issues of advanced packaging under thermal, electrical, and electromagnetic fields are discussed, as well as the methods and current research of multi-field coupling in advanced packaging. Finally, the prospect of the multi-field coupling reliability of advanced packaging is summarized to provide references for the reliability research of advanced packaging.

16.
ACS Appl Mater Interfaces ; 16(24): 31624-31635, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38839601

RESUMO

In microelectronics, one of the main 3D integration strategies consists of vertically stacking and electrically connecting various functional chips using through-silicon vias (TSVs). For the fabrication of the TSVs, one of the challenges is to conformally deposit a low dielectric constant insulator thin film at the surface of the silicon. To date, there is no universal technique that can address all types of TSV integration schemes, especially in the case requiring a low deposition temperature. In this work, an organosilicate polymer deposited by initiated chemical vapor deposition (iCVD) was developed and integrated as an insulating layer for TSVs. Process studies have shown that poly(1,3,5-trivinyl-1,3,5-trimethyl cyclotrisiloxane) (P(V3D3)) can present good conformality on high aspect ratio features by increasing the substrate temperature up to 100 °C. The trade-off is a moderate deposition rate. The thermal stability of the polymer has been investigated, and we show that a thermal annealing at 400 °C (with or without ultraviolet exposure) allows the stabilization of the dielectric films by removing residual oligomers. Then, P(V3D3) was integrated in high aspect ratio TSV (10 × 100 µm) on 300 mm silicon wafers using a standard integration flow for TSV metallization. Functional devices were successfully fabricated (including daisy chains of 754 TSVs) and electrically characterized. Our work shows that the metallization barrier should be carefully selected to eliminate the appearance of voids at the top corner of the TSV after the Cu annealing step. Moreover, an appropriate integration process should be used to avoid the appearance of cohesive cracks in the liner. This work constitutes a first proof of concept of the use of an iCVD polymer in a quasi-industrial microelectronic environment. It also highlights the benefit of iCVD as a promising technique to deposit conformal dielectric thin films in a microelectronic pilot line environment.

17.
Fish Shellfish Immunol ; 35(2): 328-33, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23665547

RESUMO

To obtain Vibrio harveyi-resistant Litopenaeus vannamei shrimp used for study on immune response of shrimp avoid vibriosis, a three-round challenge selection procedure was applied. In this procedure, resistant shrimp were selected gradually via three rounds challenge experiment with a pathogenic strain of V. harveyi at a median and controllable lethal dose of 96-h LD50 (the median lethal dose). After this procedure, the cumulative mortality of selected shrimp during 96 h after injection of V. harveyi at 2.0 × 10(6) cfu shrimp(-1) significantly decreased from 93.3% to 26.7%, the hours of beginning of death and the hours of attaining of the maximum cumulative mortality of shrimp prolonged from 4 h and 10 h to 8 h and 24 h, respectively. The LD50 of 6 h, 12 h, 24 h, 48 h and 96 h of selected shrimp significantly increased to 1.4 ± 0.1 × 10(7) (p < 0.01), 5.5 ± 0.4 × 10(6) (p < 0.01), 3.1 ± 0.2 × 10(6) (p < 0.01), 2.7 ± 0.1 × 10(6) (p < 0.01) and 2.7 ± 0.1 × 10(6) cfu shrimp(-1) (p < 0.01), about 15.9, 15.3, 9.4, 10.0 and 10.4 times of that of normal shrimp, respectively. In conclusion, the resistance of shrimp to Vibrio significantly increased after the three-round challenge selection procedure.


Assuntos
Imunidade Inata , Penaeidae/imunologia , Penaeidae/microbiologia , Vibrio/fisiologia , Animais , Aquicultura , Dose Letal Mediana
18.
Micromachines (Basel) ; 14(7)2023 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-37512702

RESUMO

With the increasing demand for high-density integration, low power consumption and high bandwidth, creating more sophisticated interconnection technologies is becoming increasingly crucial. Three-dimensional (3D) integration technology is known as the fourth-generation packaging technology beyond Moore's Law because of its advantages of low energy consumption, lightweight and high performance. Through-silicon via (TSV) is considered to be at the core of 3D integration because of its excellent electrical performance, lower power consumption, wider bandwidth, higher density, smaller overall size and lighter weight. Therefore, the particular emphasis of this review is the process flow of TSV technology. Among them, the research status of TSV hole etching, deep hole electroplating filling and chemical mechanical planarization (CMP) in TSV preparation process are introduced in detail. There are a multitude of inevitable defects in the process of TSV processing; thus, the stress problems and electrical characteristics that affect the reliability of TSV are summarized in this review. In addition, the process flow and process optimization status of through ceramic via (TCV) and through glass via (TGV) are discussed.

19.
Micromachines (Basel) ; 14(7)2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37512758

RESUMO

This paper presents an ultra-small absolute pressure sensor with a silicon-micromachined TSV backside interconnection for high-performance, high spatial resolution contact pressure sensing, including flexible-substrate applications. By exploiting silicon-micromachined TSVs that are compatibly fabricated with the pressure sensor, the sensing signals are emitted from the chip backside, thereby eliminating the fragile leads on the front-side. Such a design achieves a flat and fully passivated top surface to protect the sensor from mechanical damage, for reliable direct-contact pressure sensing. A single-crystal silicon beam-island structure is designed to reduce the deflection of the pressure-sensing diaphragm and improve output linearity. Using our group-developed microholes interetch and sealing (MIS) micromachining technique, we fabricated ultra-small piezoresistive pressure sensors with the chip size as small as 0.4 mm × 0.6 mm, in which the polysilicon-micromachined TSVs transfer the signal interconnection from the front-side to the backside of the wafer, and the sensor chips can be densely packaged on the flexible substrate via the TSVs. The ultra-small pressure sensor has high sensitivity of 0.84 mV/kPa under 3.3 V of supply voltage and low nonlinearity of ±0.09% full scale (FS) in the measurement range of 120 kPa. The proposed pressure sensors with backside-interconnection TSVs hold promise for tactile sensing applications, including flexible sensing of wearable wristwatches.

20.
Materials (Basel) ; 16(2)2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36676597

RESUMO

In this study, an ultra-high-resolution acoustic microscopy system capable of non-destructively evaluating defects that may occur in thin film structures was fabricated. It is an integrated system of the control module, activation module, and data acquisition system, in which an integrated control software for controlling each module was developed. The control module includes the mechanical, control, and ultrasonic parts. The activation module was composed of the pulser/receiver, and the data acquisition system included an A/D board. In addition, the integrated control software performs system operation and material measurement and includes an analysis program to analyze the obtained A-Scan signals in various ways. A through-silicon via (TSV) device, which is a semiconductor structure, was prepared to verify the performance of the developed system. The TSV device was analyzed using an ultra-high-resolution acoustic microscope. When the C-Scan images were analyzed, void defects with a size of 20 µm were detected at a depth of approximately 32.5 µm. A similar result could be confirmed when the cross section was measured using focused ion beam (FIB) microscopy.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa