RESUMO
Infrared (IR) neuromodulation (INM) is an emerging light-based neuromodulation approach that can reversibly control neuronal and muscular activities through the transient and localized deposition of pulsed IR light without requiring any chemical or genetic pre-treatment of the target cells. Though the efficacy and short-term safety of INM have been widely demonstrated in both peripheral and central nervous systems, the investigations of the detailed cellular and biological processes and the underlying biophysical mechanisms are still ongoing. In this review, we discuss the current research progress in the INM field with a focus on the more recently discovered IR nerve inhibition. Major biophysical mechanisms associated with IR nerve stimulation are summarized. As the INM effects are primarily attributed to the spatiotemporal thermal transients induced by water and tissue absorption of pulsed IR light, temperature monitoring techniques and simulation models adopted in INM studies are discussed. Potential translational applications, current limitations, and challenges of the field are elucidated to provide guidance for future INM research and advancement.
Assuntos
Raios Infravermelhos , Animais , HumanosRESUMO
PURPOSE: Pediatric patients with cancer often develop chemotherapy-induced fever in neutropenia (FN), requiring emergency broad-spectrum antibiotics. Continuous temperature monitoring can lead to earlier FN detection and therapy with improved outcomes. We aimed to compare the feasibility of continuous core temperature monitoring with timely data availability between two wearable devices (WDs) in pediatric oncology patients undergoing chemotherapy. METHODS: In this prospective observational two-center study, 20 patients (median age: 8 years) undergoing chemotherapy simultaneously wore two WDs (CORE®, Everion®) for 14 days. The predefined goal was core temperature recorded in sufficient quality and available within ≤ 30 min during ≥ 18/24 h for ≥ 7/14 days in more than 15 patients. RESULTS: More patients reached the goal with CORE® (n = 13) versus Everion® (n = 3) (difference, 50% p < 0.001). After correcting for the transmission bottleneck caused by two WDs transmitting via one gateway, these numbers increased (n = 15 versus n = 14; difference, 5%; p = 0.69). CORE® measurements corresponded better to ear temperatures (n = 528; mean bias, - 0.07 °C; mean absolute difference, 0.35 °C) than Everion® measurements (n = 532; - 1.06 °C; 1.10 °C). Acceptance rates for the WDs were 95% for CORE® and 89% for Everion®. CONCLUSION: The CORE® fulfilled the predefined feasibility criterion (15 of 20 patients) after correction for transmission bottleneck, and the Everion® nearly fulfilled it. Continuous core temperature recording of good quality and with timely data availability was feasible from preschool to adolescent patients undergoing chemotherapy for cancer. These results encourage the design of randomized controlled trials on continuously monitored core temperature in pediatric patients. CLINICALTRIALS: gov (NCT04914702) on June 7, 2021.
Assuntos
Neoplasias , Dispositivos Eletrônicos Vestíveis , Pré-Escolar , Adolescente , Humanos , Criança , Temperatura , Temperatura Corporal , Neoplasias/tratamento farmacológico , Estudos ProspectivosRESUMO
The temperature of the water wall in the furnace chamber is extremely important for the daily operation of a boiler. Considering the high temperature and dusty environment in the furnace, a temperature measurement device mainly composed of four parts (armored temperature sensor, in-furnace heat-collecting block, out-furnace fixing base, and protective cannula) was designed in this study, which could be used to directly obtain the temperature of the in-furnace water-wall. Numerical simulations of temperature measurement devices with different heat-collecting block structures were carried out using the computer fluid dynamics method. After comparing the measurement accuracy and considering the practical application scenarios, the optimized heat-collecting block structure with a specific expansion gap (0.5 mm wide and 4 mm deep) was selected for practical application. Such a temperature measurement device was then applied to a 1000 MW ultra-supercritical coal-fired boiler in China, and the tested in-furnace water-wall temperature data were in good agreement with relevant research. Compared with the conventional temperature measurement device arranged outside the furnace, the in-furnace water-wall temperature-measurement device adopted in this study has a more sensitive response characteristic and can directly reflect the temperature of the water wall inside the furnace. In addition, it can also reflect the local slag formation state of the water wall and has a long service life.
RESUMO
Body temperature is one of the most important physiological parameters of a human being used to assess his basic vital functions. In medical practice, various types of measuring instruments are used to measure temperature, such as liquid thermometers, electronic thermometers, non-contact ear thermometers, and non-contact forehead thermometers. Such body temperature measurement techniques require the connection of appropriate sensors to a person, and non-contact thermometers operate over short distances and force a specific position of the person during the measurement. As a result, using the above methods, it is practically impossible to perform body temperature measurements of a moving human being. A thermal imaging camera can be used effectively for the purpose of the temperature measurement of moving objects, but the remote measurement of a human body temperature using a thermal imaging camera is affected by many factors that are difficult to control. Accurate remote measurement of human body temperature requires a measurement system that implements a specialized temperature determination algorithm. This article presents a model of a measurement system that facilitates the development of a highly accurate temperature measurement method. For the model, its parameters were determined on the calibration stand. The correct operation of the developed method and the effectiveness of temperature measurement have been confirmed by tests on a test stand using reference radiation sources.
RESUMO
In the validation of microclimate simulation software, the comparison of simulation results with on-site measurements is a common practice. To ensure reliable validation, it is crucial to utilize high-quality temperature sensors with a deviation smaller than the average absolute error of the simulation software. However, previous validation campaigns have identified significant absolute errors, particularly during periods of high solar radiation, possibly attributed to the use of non-ventilated radiation shields. This study addresses the issue by introducing a ventilated radiation shield created through 3D printing, aiming to enhance the accuracy of measurements on cloudless summer days with intense solar radiation. The investigation employs two pairs of sensors, each comprising one sensor with a ventilated and one with a non-ventilated radiation shield, placed on a south-oriented facade with two distinct albedos. Results from the measurement campaign indicate that the air temperature measured by the non-ventilated sensor is elevated by up to 2.8 °C at high albedo and up to 1.9 °C at a low albedo facade, compared to measurements with the ventilated radiation shield. An in-depth analysis of means, standard deviations, and 95% fractiles highlights the strong dependency of the non-ventilated sensor error on wind velocity. This research underscores the importance of employing ventilated radiation shields for accurate microclimate measurements, particularly in scenarios involving high solar radiation, contributing valuable insights for researchers and practitioners engaged in microclimate simulation validation processes.
RESUMO
In this paper, a temperature measurement system with NTC (Negative Temperature Coefficient) thermistors was designed. An MCU (Micro Control Unit) primarily operates by converting the voltage value collected by an ADC (Analog-to-Digital Converter) into the resistance value. The temperature value is then calculated, and a DAC (Digital-to-Analog Converter) outputs a current of 4 to 20 mA that is linearly related to the temperature value. The nonlinear characteristics of NTC thermistors pose a challenging problem. The nonlinear characteristics of NTC thermistors were to a great extent solved by using a resistance ratio model. The high precision of the NTC thermistor is obtained by fitting it with the Hoge equation. The results of actual measurements suggest that each module works properly, and the temperature measurement accuracy of 0.067 °C in the range from -40 °C to 120 °C has been achieved. The uncertainty of the output current is analyzed and calculated with the uncertainty of 0.0014 mA. This type of system has broad potential applications in industry fields such as the petrochemical industry.
RESUMO
This paper presents the construction of an innovative high-temperature sensor based on the optical principle. The sensor is designed especially for the measurement of exhaust gases with a temperature range of up to +850 °C. The methodology is based on two principles-luminescence and dark body radiation. The core of this study is the description of sensing element construction together with electronics and the system of photodiode dark current compensation. An advantage of this optical-based system is its immunity to strong magnetic fields. This study also discusses results achieved and further steps. The solution is covered by a European Patent.
RESUMO
The best method to prevent error due to inhomogeneity is to use a new thermocouple design-the thermocouple with controlled temperature field (TCTF). It uses the auxiliary furnace to control the temperature field along its legs. Such a design allows setting and maintaining the temperature field along the thermocouple (TC) legs for the sensor. Error due to inhomogeneity of TCs cannot appear in a stable temperature field. However, the auxiliary furnace and TCs, to control the temperature field, have errors, so the temperature field along the main TC is maintained with some error. This leads to residual error due to acquired inhomogeneity of the TCTF. We constructed the mathematical models to fit the experimental data of error due to drift for the type K TC. The authors used the constructed models to study error due to inhomogeneity of the TCTF and the conventional type K TC under considerable changes in temperature field. The main results of modelling are as follows: (i) if the changes in temperature field exceed 7 °C, error due to inhomogeneity of the TCTF is lesser than that of the conventional TC; (ii) the maximum error due to inhomogeneity of the conventional type K TC is 10.75 °C; (iii) the maximum error due to inhomogeneity of the TCTF is below 0.2 °C.
RESUMO
Multispectral thermometry is based on the law of blackbody radiation and is widely used in engineering practice today. Temperature values can be inferred from radiation intensity and multiple sets of wavelengths. Multispectral thermometry eliminates the requirements for single-spectral and spectral similarity, which are associated with two-colour thermometry. In the process of multispectral temperature inversion, the solution of spectral emissivity and multispectral data processing can be seen as the keys to accurate thermometry. At present, spectral emissivity is most commonly estimated using assumption models. When an assumption model closely matches an actual situation, the inversion of the temperature and the accuracy of spectral emissivity are both very high; however, when the two are not closely matched, the inversion result is very different from the actual situation. Assumption models of spectral emissivity exhibit drawbacks when used for thermometry of a complex material, or any material whose properties dynamically change during a combustion process. To address the above problems, in the present study, we developed a multispectral thermometry method based on optimisation ideas. This method involves analysing connections between measured temperatures of each channel in a multispectral temperature inversion process; it also makes use of correlations between multispectral signals at different temperatures. In short, we established a multivariate temperature difference correlation function based on the principles of multispectral radiometric thermometry, using information correlations between data for each channel in a temperature inversion process. We then established a high-precision thermometry model by optimising the correlation function and correcting any measurement errors. This method simplifies the modelling process so that it becomes an optimisation problem of the temperature difference function. This also removes the need to assume the relationships between spectral emissivity and other physical quantities, simplifying the process of multispectral thermometry. Finally, this involves correction of the spectral data so that any impact of measurement error on the thermometry is reduced. In order to verify the feasibility and reliability of the method, a simple eight-channel multispectral thermometry device was used for experimental validation, in which the temperature emitted from a blackbody furnace was identified as the standard value. In addition, spectral data from the 468-603 nm band were calibrated within a temperature range of 1923.15-2273.15 K, resulting in multispectral thermometry based on optimisation principles with an error rate of around 0.3% and a temperature calculation time of less than 3 s. The achieved level of inversion accuracy was better than that obtained using either a secondary measurement method (SMM) or a neural network method, and the calculation speed achieved was considerably faster than that obtained using the SMM method.
RESUMO
In this study, the fluorescence properties of Lumisis, a phosphor that can be easily applied to ultrafine wires, were evaluated. By evaluating the wavelength characteristics of Lumisis phosphor, we investigated the possibility of applying it to a dual-wavelength laser-induced fluorescence (LIF) measurement system and evaluated the accuracy of temperature measurements. The difference between the decrease in the percentage intensities of the red and green fluorescence of Lumisis phosphors showed that two-color LIF was possible. The Lumisis phosphor-mixture ratio was optimized as 1:1.25, and the average measurement error of the fluorescent wire was 0.20 K, as evaluated through uncertainty analysis. Finally, the application of this measurement method to hot air jet phenomena showed that this method accurately captures the temperature changes in hot air, thus proving its validity.
RESUMO
The application of distributed fiber optic strain and temperature measurement can be utilized to address a multitude of measurement tasks across a diverse range of fields, particularly in the context of structural health monitoring in the domains of building construction, civil engineering, and special foundation engineering. However, a comprehensive understanding of the influences on the measurement method and the sensors is essential to prevent misinterpretations or measurement deviations. In this context, this study investigated the effects of moisture exposure, including various salt solutions and a high pH value, on a distributed strain measurement using Rayleigh backscattering. Three fiber optic sensors with different coating materials and one uncoated fiber were exposed to five different solutions for 24 h. The study revealed significant discrepancies (â¼38%) in deformation between the three coating types depending on the surrounding solution. Furthermore, in contrast to the prevailing literature, which predominantly describes swelling effects, a negative deformation (â¼-47 µÎµ) was observed in a magnesium chloride solution. The findings of this study indicate that corresponding effects can impact the precision of measurement, potentially leading to misinterpretations. Conversely, these effects could be used to conduct large-scale monitoring of chemical components using distributed fiber optic sensing.
RESUMO
We aimed to compare rectal temperature (Trec) and gastro-intestinal temperature (TGI) during passive heating and subsequent recovery with and without ice slurry ingestion. Twelve males (age: 25 ± 4 years, body mass index: 25.7 ± 2.5 kg m-2) were immersed in hot water on two occasions (Trec elevation: 1.82 ± 0.08°C). In the subsequent 60-min recovery in ambient conditions, participants ingested either 6.8 g kg-1 of ice slurry (-0.6°C, ICE) or control drink (37°C, CON). During passive heating, Trec was lower than TGI (P < 0.001), in the recovery, Trec was higher than TGI (P < 0.001). During passive heating, mean bias and 95%LoA (Limits of Agreement) were -0.10(±0.25)°C and -0.12(±0.36)°C for CON and ICE, respectively. In the recovery, mean bias and 95%LoA were 0.30(±0.60)°C and 0.42(±0.63)°C for CON and ICE, respectively. Trec and TGI differed during both heating and recovery, and less favourable agreement between Trec and TGI was found in the recovery from passive heating with or without ice slurry ingestion.
Assuntos
Temperatura Corporal , Calefação , Masculino , Humanos , Adulto Jovem , Adulto , Temperatura , Temperatura Alta , Regulação da Temperatura CorporalRESUMO
To identify and prevent perioperative hypothermia, most surgical patients require a non-invasive, accurate, convenient, and continuous core temperature method, especially for patients undergoing major surgery. This study validated the precision and accuracy of a cutaneous zero-heat-flux thermometer and its performance in detecting intraoperative hypothermia. Adults undergoing major non-cardiac surgeries with general anaesthesia were enrolled in the study. Core temperatures were measured with a zero-heat-flux thermometer, infrared tympanic membrane thermometer, and oesophagal monitoring at 15-minute intervals. Taking the average value of temperature measured in the tympanic membrane and oesophagus as a reference, we assessed the agreement using the Bland-Altman analysis and linear regression methods. Sensitivity, specificity, and predictive values of detecting hypothermia were estimated. 103 patients and one thousand sixty-eight sets of paired temperatures were analyzed. The mean difference between zero-heat-flux and the referenced measurements was -0.03 ± 0.25 °C, with 95% limits of agreement (-0.52 °C, 0.47 °C) was narrow, with 94.5% of the differences within 0.5 °C. Lin's concordance correlation coefficient was 0.90 (95%CI 0.89-0.92). The zero-heat-flux thermometry detected hypothermia with a sensitivity of 82% and a specificity of 90%. The zero-heat-flux thermometer is in good agreement with the reference core temperature based on tympanic and oesophagal temperature monitoring in patients undergoing major surgeries, and appears high performance in detecting hypothermia.
Assuntos
Hipotermia , Termometria , Adulto , Humanos , Temperatura Corporal , Temperatura , Temperatura Alta , Monitorização Intraoperatória/métodos , Termômetros , EsôfagoRESUMO
Temperature measurements with high spatial resolution and accuracy can provide crucial data for understanding the changing process of microregion. Non-contact ratiometric fluorescence thermometers have received widespread attention for their sensitivity and interference resistibility. However, polymer and organic dye thermometers with such ratiometric fluorescence are very rare, and their applicability and processability are limited. In this study, novel tridurylboron compounds PPB1, PPB2, and PPB3 are designed and synthesized. They exhibit significant temperature responsive ratiometric fluorescence when dispersed in thermoplastic polyurethane elastomers (TPU). With a self-referencing feature and protection of TPU solid polymer, such fluorescence thermometers possess strong interference resistibility. From -10° to 60 °C, the fluorescence peak of PPB1-TPU system redshifted by 41 nm, the fluorescence color changes from blue to green. For the fluorescence ratiometric temperature measurement procedure, the absolute sensitivity is 14.5% °C-1 (40 °C) and relative sensitivity is 6.3% °C-1 (35 °C), which is much higher than reported solid polymer fluorescence thermometers. The temperature-responsive ranges can be adjusted by altering the types of polymer substrate and the number of the substituents. Such tridurylboron-TPU polymer fluorescence thermometers can be applied in aqueous environment and processed into devices of various shapes and sizes, demonstrating great potential for application.
RESUMO
Rectal temperature measurement (RTM) from crime scenes is an important parameter for temperature-based time of death estimation (TDE). Various influential variables exist in TDE methods like the uncertainty in thermal and environmental parameters. Although RTM depends in particular on the location of measurement position, this relationship has never been investigated separately. The presented study fills this gap using Finite Element (FE) simulations of body cooling. A manually meshed coarse human FE model and an FE geometry model developed from the CT scan of a male corpse are used for TDE sensitivity analysis. The coarse model is considered with and without a support structure of moist soil. As there is no clear definition of ideal rectal temperature measurement location for TDE, possible variations in RTM location (RTML) are considered based on anatomy and forensic practice. The maximum variation of TDE caused by RTML changes is investigated via FE simulation. Moreover, the influence of ambient temperature, of FE model change and of the models positioning on a wet soil underground are also discussed. As a general outcome, we notice that maximum TDE deviations of up to ca. 2-3 h due to RTML deviations have to be expected. The direction of maximum influence of RTML change on TDE generally was on the line caudal to cranial.
RESUMO
Healthy adult horses can balance accumulation and dissipation of body heat to maintain their body temperature between 37.5 and 38.5 °C, when they are in their thermoneutral zone (5 to 25 °C). However, under some circumstances, such as following strenuous exercise under hot, or hot and humid conditions, the accumulation of body heat exceeds dissipation and horses can suffer from heat stress. Prolonged or severe heat stress can lead to anhidrosis, heat stroke, or brain damage in the horse. To ameliorate the negative effects of high heat load in the body, early detection of heat stress and immediate human intervention is required to reduce the horse's elevated body temperature in a timely manner. Body temperature measurement and deviations from the normal range are used to detect heat stress. Rectal temperature is the most commonly used method to monitor body temperature in horses, but other body temperature monitoring technologies, percutaneous thermal sensing microchips or infrared thermometry, are currently being studied for routine monitoring of the body temperature of horses as a more practical alternative. When heat stress is detected, horses can be cooled down by cool water application, air movement over the horse (e.g., fans), or a combination of these. The early detection of heat stress and the use of the most effective cooling methods is important to improve the welfare of heat stressed horses.
Assuntos
Temperatura Alta , Respiração , Humanos , Cavalos , Animais , Umidade , Temperatura Corporal , Febre , Regulação da Temperatura CorporalRESUMO
OBJECTIVE: To investigate the impact of with tympanostomy tubes (TT) on infrared tympanic membrane thermometer (ITMT) results and to provide a systematic review of ITMT results in non-naïve tympanic membranes. STUDY DESIGN: Original prospective blinded case series and systematic literature review. SETTINGS: A single tertiary university-affiliated medical center. METHODS: ITMT measurements of patients with unilateral TT and contralateral naïve control ear were randomly conducted by a single investigator blinded to the TT side before and after cerumen was removed from the external auditory canals. A systematic literature search of "MEDLINE" via "PubMed," "Embase," and "Google Scholar" on comparable published cases was performed. RESULTS: The mean paired differences (95% confidence interval [CI]) between ventilated and non-ventilated ears before and after cerumen removal were 0.08 ºC/0.14 ºF (-0.04 to 0.19 ºC/- 0.07º-0.34º) and 0.62 ºC/1.12 ºF (0.04-0.25 ºC/0.07-0.45 ºF), respectively (P < 0.001 and P = 0.01, respectively). CONCLUSION: These findings support the validity and accuracy of ITMT in the setting of ventilated ears.
Assuntos
Termometria , Membrana Timpânica , Humanos , Estudos Prospectivos , Termômetros , Meato Acústico Externo , Raios InfravermelhosRESUMO
Temperature transducers are frequently employed to keep track of process variables with different kinds of industrial controllers. One of the widely used temperature sensors is Pt100. A novel approach of utilizing an electroacoustic transducer in signal conditioning for Pt100 is proposed in this paper. A "signal conditioner" is a resonance tube filled with air, which is operated in a free resonance mode. The Pt100 wires are connected to one of the leads of the speaker in the resonance tube where the temperature changes, which is related to Pt100 resistance. The resistance affects the amplitude of the standing wave that is detected by an electrolyte microphone. An algorithm for measuring the amplitude of the speaker signal is described, as well as the building and functioning of the electroacoustic resonance tube signal conditioner. The microphone signal is acquired as a voltage using LabVIEW software. A virtual instrument (VI) developed under LabVIEW provides a measure of the voltage using standard VIs. The findings of the experiments reveal a link between the measured amplitude of the standing wave within the tube and the change in Pt100 resistance as the ambient temperature changes. Additionally, the suggested method may interface with any computer system when a sound card is added to it without the need for any extra measuring tools. The maximum nonlinearity error at full-scale deflection (FSD) is estimated at roughly 3.77%, and the experimental results and a regression model are used to assess the relative inaccuracy of the developed signal conditioner. When comparing the proposed approach with well-known approaches for Pt100 signal conditioning, the proposed one has several advantages such as its simplicity of connecting Pt100 to a personal computer directly via the sound card of any personal computer. In addition, there is no need for a reference resistance to perform a temperature measurement using such a signal conditioner.
RESUMO
Temperature transducers are commonly used to monitor process parameters that are controlled by various types of industrial controllers. The purpose of this study is to design and model a simple microcontroller-based acoustic temperature transducer based on the variations of resonance conditions in a cylindrical resonance tube. The transducer's operation is based on the generation of an acoustic standing wave in the free resonance mode of generation within a cylindrical resonance tube which is converted into a train of pulses using Schmitt trigger circuit. The frequency of the generated standing wave (i.e., the train of pulses) is measured by the Arduino Uno microcontroller, where a digital pin is used to acquire pulses that are counted using a build-in software function in an Arduino IDE environment. Experimental results are performed for three sizes of diameters to investigate the effect of the diameter of resonance tube on the obtained results. The maximum nonlinearity error according to Full-Scale Deflection (FSD) is about 2.3 percent, and the relative error of the transducer is evaluated using experimental findings and the regression model. The circuit simplicity and design of the suggested transducer, as well as the linearity of its measurements, are notable.
Assuntos
Acústica , Som , Temperatura , Vibração , TransdutoresRESUMO
This paper describes a method for increasing the accuracy and precision of temperature measurements of a liquid based on the central limit theorem. A thermometer immersed in a liquid exhibits a response with determined accuracy and precision. This measurement is integrated with an instrumentation and control system that imposes the behavioral conditions of the central limit theorem (CLT). The oversampling method exhibited an increasing measurement resolution. Through periodic sampling of large groups, an increase in the accuracy and formula of the increase in precision is developed. A measurement group sequencing algorithm and experimental system were developed to obtain the results of this system. Hundreds of thousands of experimental results are obtained and seem to demonstrate the proposed idea's validity.