RESUMO
OBJECTIVES: This finite element study aimed to simulate maxillary canine movement during anterior teeth retraction. MATERIALS AND METHODS: Three methods of maxillary canine movement including miniscrew sliding with high hooks (MSH), miniscrew sliding with low hooks (MSL), and the traditional sliding method (TS) without using miniscrews were simulated using three-dimensional finite element analysis. The initial displacement of the maxillary canine, the maximum principal stress of the periodontal ligament and the Von Mises stress were calculated. RESULTS: The distolingual tipping movements of the canine were shown in three movement modes. MSH showed a small tendency to lingual tipping movement and a extrusion movement while MSL had the largest lingual inclination. TS demonstrated a tendency toward distolingual torsion displacement. Compressive stress values were mainly concentrated in the range - 0.003 to -0.006 MPa. For tensile stress, the distribution of MSH and MSL was concentrated in the range 0.005 to 0.009 MPa, TS was mainly distributed about 0.003 MPa. Von Mises equivalent stress distribution showed no significant difference. CONCLUSIONS: The loss of tooth torque was inevitable, irrespective of which method was used to close the extraction space. However, miniscrew application and higher hooks reduced the loss of torque and avoided lingual rotation. CLINICAL RELEVANCE: This study shows that miniscrew implants with different hooks can better control the movement of the maxillary canines. The non-invasive nature of the finite element analysis and its good simulation of dental stress and instantaneous motion trend have a clinical advantage in the analysis of tooth movement.
Assuntos
Dente Canino , Técnicas de Movimentação Dentária , Dente Pré-Molar , Estresse Mecânico , Análise de Elementos Finitos , Torque , Técnicas de Movimentação Dentária/métodos , MaxilaRESUMO
OBJECTIVES: To establish a three-dimensional finite element model of the upper palate, pharyngeal cavity, and levator veli palatini muscle in patients with unilateral complete cleft palate, simulate two surgical procedures that the two-flap method and Furlow reverse double Z method, observe the stress distribution of the upper palate soft tissue and changes in pharyngeal cavity area after different surgical methods, and verify the accuracy of the model by reconstructing and measuring the levator veli palatini muscle. MATERIALS AND METHODS: Mimics, Geomagic, Ansys, and Hypermesh were applied to establish three-dimensional finite element models of the pharyngeal cavity, upper palate, and levator veli palatini muscle in patients with unilateral complete cleft palate. The parameters including length, angle, and cross-sectional area of the levator veli palatini muscle etc. were measured in Mimics, and two surgical procedures that two-flap method and Furlow reverse double Z method were simulated in Ansys, and the area of pharyngeal cavity was measured by hypermesh. RESULTS: A three-dimensional finite element model of the upper palate, pharyngeal cavity, and bilateral levator veli palatini muscle was established in patients with unilateral complete cleft palate ; The concept of horizontal projection characteristics of the palatal dome was applied to the finite element simulation of cleft palate surgery, vividly simulating the displacement and elastic stretching of the two flap method and Furlow reverse double Z method during the surgical process; The areas with the highest stress in the two-flap method and Furlow reverse double Z method both occur in the hard soft palate junction area; In resting state, as measured, the two flap method can narrow the pharyngeal cavity area by 50.9%, while the Furlow reverse double Z method can narrow the pharyngeal cavity area by 65.4%; The measurement results of the levator veli palatini muscle showed no significant difference compared to previous studies, confirming the accuracy of the model. CONCLUSIONS: The finite element method was used to establish a model to simulate the surgical procedure, which is effective and reliable. The area with the highest postoperative stress for both methods is the hard soft palate junction area, and the stress of the Furlow reverse double Z method is lower than that of the two-flap method. The anatomical conditions of pharyngeal cavity of Furlow reverse double Z method are better than that of two-flap method in the resting state. CLINICAL RELEVANCE: This article uses three-dimensional finite element method to simulate the commonly used two-flap method and Furlow reverse double Z method in clinical cleft palate surgery, and analyzes the stress distribution characteristics and changes in pharyngeal cavity area of the two surgical methods, in order to provide a theoretical basis for the surgeon to choose the surgical method and reduce the occurrence of complications.
Assuntos
Fissura Palatina , Insuficiência Velofaríngea , Humanos , Fissura Palatina/cirurgia , Fissura Palatina/complicações , Análise de Elementos Finitos , Insuficiência Velofaríngea/complicações , Insuficiência Velofaríngea/cirurgia , Músculos Palatinos/cirurgia , Palato Mole/cirurgia , Palato DuroRESUMO
OBJECTIVE: To assess stress distribution in peri-implant bone and attachments of mandibular overdentures retained by small diameter implants, and to explore the impact of implant distribution on denture stability. METHODS: Through three-dimensional Finite Element Analysis (3D FEA), four models were established: three models of a two mandibular implants retained overdenture (IOD) and one model of a conventional complete denture (CD). The three IOD models consisted of one with two implants in the bilateral canine area, another with implants in the bilateral lateral incisor area, and the third with one implant in the canine area, and another in the lateral incisor area. Three types of loads were applied on the overdenture for each model: a 100 N vertical load and a inclined load on the left first molar, and a100N vertical load on the lower incisors. The stress distribution in the peri-implant bone, attachments, and the biomechanical behaviors of the overdentures were analyzed. RESULTS: Despite different distribution of implants, the maximum stress values in peri-implant bone remained within the physiological threshold for all models across three loading conditions. The dispersed implant distribution design (implant in the canine area) exhibited the highest maximum stress in peri-implant bone (822.8 µe) and the attachments (275 MPa) among the three IOD models. The CD model demonstrated highest peak pressure on mucosa under three loading conditions (0.8188 Mpa). The contact area between the denture and mucosa of the CD model was smaller than that in the IOD models under molar loading, yet it was larger in the CD model compared to the IOD model under anterior loading. However, the contact area between the denture and mucosa under anterior loading in all models was significantly smaller than those under molar loading. The IOD in all three models exhibited significantly less rotational movement than the complete denture. Different implant positions had minimal impact on the rotational movement of the IOD. CONCLUSION: IOD with implants in canine area exhibited the highest maximum stress in the peri-implant bone and attachments, and demonstrated increased rotational movement. The maximum principal stress was concentrated around the neck of the small diameter one-piece implant, rather than in the abutment. An overdenture retained by two implants showed better stability than a complete denture.
Assuntos
Implantes Dentários , Humanos , Revestimento de Dentadura , Análise de Elementos Finitos , Prótese Total , Mandíbula , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário/métodos , Retenção de DentaduraRESUMO
OBJECTIVES: After bonding brackets to the first deciduous molar in a 2 × 4 technique, a three-dimensional finite element analysis (3D FEA) is used to demonstrate the biomechanical changes in an orthodontic system. This study aims to opt for the appropriate type of orthodontic technology by analyzing and comparing the mechanical systems produced by two types of 2 × 4 techniques employing rocking-chair archwires. MATERIALS AND METHODS: Herein, the maxilla and maxillary dentition are modeled by cone beam computed tomography (CBCT) and 3D FEA. Common clinically used 0.016-inch round archwires (material: titanium-molybdenum alloy and stainless-steel) and 0.018-inch round archwires (material: titanium-molybdenum alloy and stainless-steel) are bent into the shape of a rocking chair with a depth of 3 mm. The forces and moments applied to the brackets are transferred to the dentition to evaluate the biomechanical effects of the 2 × 4 technique after the bracket is bonded to the first deciduous molar. RESULTS: For the central incisor, the teeth-moving distance in all three directions increases with bracket bonding to the first deciduous molar applying the 0.016-inch rocking-chair archwire. For the lateral incisor, the tooth root moves toward the gingival side when using 0.016-inch and 0.018-inch archwires. Moreover, for the same archwire size, the lateral incisors move toward the gingival side by bonding the bracket to the first deciduous molar. After bonding a bracket to the first deciduous molar, using rocking-chair archwires of 0.016 inch or 0.018 inch, the buccal movement distance of the first molar crown increases in the X-axis direction. In the Y-axis and Z-axis directions, the modified 2 × 4 technique significantly increases the effect of backward-tipping compared with the traditional 2 × 4 technique. CONCLUSIONS: In clinical practice, the modified 2 × 4 technique can be used to increase the movement distance of anterior teeth to a certain extent and accelerate the orthodontic teeth movement. Moreover, the modified 2 × 4 technique is better in anchorage conservation of the first molar than the traditional technique. CLINICAL RELEVANCE: Although the traditional 2 × 4 technique is widely used in early orthodontic treatment, we found mucosal damage and abnormal archwire deformation might affect orthodontic treatment time and effect. The modified 2 × 4 technique is a novel approach that avoids these drawbacks and improves orthodontic treatment efficiency.
Assuntos
Braquetes Ortodônticos , Fios Ortodônticos , Ligas Dentárias , Análise de Elementos Finitos , Titânio , Molibdênio , Ligas , Técnicas de Movimentação Dentária/métodos , Aço , Aço Inoxidável , Teste de MateriaisRESUMO
BACKGROUND: Correct torque of the incisors is beneficial in the assessment of the effects of orthodontic treatment. However, evaluating this process effectively remains a challenge. Improper anterior teeth torque angle can cause bone fenestrations and exposure of the root surface. METHODS: A three-dimensional finite element model of the maxillary incisor torque controlled by a homemade four-curvature auxiliary arch was established. The four-curvature auxiliary arch placed on the maxillary incisors was divided into four different state groups, among which 2 groups had tooth extraction space retracted traction force set to 1.15 N. Initial displacements and pressure stresses of the periodontal tissue in the maxillary incisors and molars were calculated after torque forces (0.5, 1, 1.5, and 2 N) were applied to the teeth at different stable states. RESULTS: The effect of using the four-curvature auxiliary arch on the incisors was significant but did not affect the position of the molars. Given the absence of tooth extraction space, when the four-curvature auxiliary arch was used in conjunction with absolute anchorage, the recommended force value was < 1.5 N. In the other 3 groups (i.e., molar ligation, molar retraction, and microimplant retraction groups), the recommended force value was < 1 N. The application of a four-curvature auxiliary arch did not influence the molar periodontal and displacement. CONCLUSION: A four-curvature auxiliary arch may treat severely upright anterior teeth and correct cortical fenestrations of the bone and root surface exposure.
Assuntos
Incisivo , Dente Molar , Humanos , Análise de Elementos Finitos , Maxila , Ligamento Periodontal , Técnicas de Movimentação Dentária/métodosRESUMO
OBJECTIVE: This study aimed to provide evidence for the clinical application of single short implants by establishing an anisotropic, three-dimensional (3D) finite element mandible model and simulating the effect of crown-to-implant ratio (CIR) on biomechanics around short implants with different osseointegration rates. METHODS: Assuming that the bone is transversely isotropic by finite element method, we created four distinct models of implants for the mandibular first molar. Subsequently, axial and oblique forces were applied to the occlusal surface of these models. Ultimately, the Abaqus 2020 software was employed to compute various mechanical parameters, including the maximum von Mises stress, tensile stress, compressive stress, shear stress, displacement, and strains in the peri-implant bone tissue. RESULTS: Upon establishing consistent osseointegration rates, the distribution of stress exhibited similarities across models with varying CIRs when subjected to vertical loads. However, when exposed to inclined loads, the maximum von Mises stress within the cortical bone escalated as the CIR heightened. Among both loading scenarios, notable escalation in the maximum von Mises stress occurred in the model featuring a CIR of 2.5 and an osseointegration rate of 25%. Conversely, other models displayed comparable strength. Notably, stress and strain values uniformly increased with augmented osseointegration across all models. Furthermore, an increase in osseointegration rate correlated with reduced maximum displacement for both cortical bone and implants. CONCLUSIONS: After fixing osseointegration rates, the stress around shorter implants increased as the CIR increased under inclined loads. Thus, the effect of lateral forces should be considered when selecting shorter implants. Moreover, an implant failure risk was present in cases with a CIR ≥ 2.5 and low osseointegration rates. Additionally, the higher the osseointegration rate, the more readily the implant can achieve robust stability.
Assuntos
Implantes Dentários , Osseointegração , Humanos , Dente Molar , Mandíbula , CoroasRESUMO
OBJECTIVE: To analyze the cement flow in the abutment margin-crown platform switching structure by using the three-dimensional finite element analysis, in order to prove that whether the abutment margin-crown platform switching structure can reduce the inflow depth of cement in the implantation adhesive retention. METHODS: By using ANSYS 19.0 software, two models were created, including the one with regular margin and crown (Model one, the traditional group), and the other one with abutment margin-crown platform switching structure (Model two, the platform switching group). Both abutments of the two models were wrapped by gingiva, and the depth of the abutment margins was 1.5 mm submucosal. Two-way fluid structure coupling calculations were produced in two models by using ANSYS 19.0 software. In the two models, the same amount of cement were put between the inner side of the crowns and the abutments. The process of cementing the crown to the abutment was simulated when the crown was 0.6 mm above the abutment. The crown was falling at a constant speed in the whole process spending 0.1 s. Then we observed the cement flow outside the crowns at the time of 0.025 s, 0.05 s, 0.075 s, 0.1 s, and measured the depth of cement over the margins at the time of 0.1 s. RESULTS: At the time of 0 s, 0.025 s, 0.05 s, the cements in the two models were all above the abutment margins. At the time of 0.075 s, in Model one, the gingiva was squeezed by the cement and became deformed, and then a gap was formed between the gingiva and the abutment into which the cement started to flow. In Model two, because of the narrow neck of the crown, the cement flowed out from the gingival as it was pressed by the upward counterforce from the gingival and the abutment margin. At the time of 0.1 s, in Model one, the cement continued to flow deep inside with the gravity force and pressure, and the depth of the cement over the margin was 1 mm. In Model two, the cement continued to flow out from the gingival at the time of 0.075 s, and the depth of the cement over the margin was 0 mm. CONCLUSION: When the abutment was wrapped by the gingiva, the inflow depth of cement in the implantation adhesive retention can be reduced in the abutment margin-crown platform switching structure.
Assuntos
Cimentação , Gengiva , Análise de Elementos Finitos , Cimentação/métodos , Coroas , Dente Suporte , Cimentos Dentários , Análise do Estresse DentárioRESUMO
INTRODUCTION: To analyze the stress distribution of the all-ceramic endocrown with different base materials and thicknesses using three-dimensional finite element analysis. METHODS: A endodontically treated maxillary premolar was scanned by micro-CT, a three-dimensional finite element model of the endocrown with fluid resin as the base material was divided into control (0 mm), 1 mm, 2 mm, and 3 mm groups according to base thickness. Three kinds of conventional base materials were used and divided into glass ion group (A), fluid resin group (B), and nanocomposite resin group (C), and a three-dimensional finite element model of the endocrown with 1.0 mm thickness of base was established. A static loading with axial and 45° direction was applied to each model, the stress distribution of each part of the endocrown was analyzed under different base materials and thicknesses. RESULTS: The different thickness of the base layer has an influence on the components of the restoration and the tooth. The stress in the control group was the largest. The stress was the lowest when the thickness of the base layer was 1 mm; The maximum of the equivalent stress, the first, second, and third principal stress in the endocrown, abutment, and alveolar bone, are basically the same with the different base materials. The stress on the base layer increases with the elastic modulus of base materials increases. CONCLUSIONS: The base layer played a force buffering effect on the dental body restored with endocrowns, and the effect was the best at 1 mm; The selection of base material has little influence on the whole, but in order to protect the weak tissues of the cavity bottom, the base material with lower elastic modulus can be used.
Assuntos
Cerâmica , Coroas , Dente Pré-Molar , Resinas Compostas , Análise do Estresse Dentário/métodos , Análise de Elementos Finitos , Humanos , Teste de MateriaisRESUMO
OBJECTIVE: This study aimed to evaluate timing of fixation to retard bone absorption using finite element analysis(FEA). METHODS: Volunteer CT images were used to construct four models of mandibles with varying degrees of alveolar bone resorption. By simulating occlusal force loading, biomechanical analysis was made on the periodontal membrane, tooth root and surrounding bone (both cancellous and cortical) of mandibular dentition. RESULTS: The von Mises stress value of the periodontal structures was positively related with the degree of alveolar bone resorption, and the von Mises stress at the interface between the periodontal membrane and tooth root was increased significantly in moderate to severe periodontitis models. The von Mises stress at the interface between the periodontal cortical bone and cancellous bone was increased significantly in the severe periodontitis model. And the von Mises stress value with oblique loading showed significantly higher than vertical loading. CONCLUSION: Teeth with moderate to severe periodontitis, loosened tooth fixation can be used to retard bone absorption.
Assuntos
Perda do Osso Alveolar , Periodontite , Raiz Dentária , Perda do Osso Alveolar/diagnóstico por imagem , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Mandíbula , Estresse Mecânico , Raiz Dentária/cirurgiaRESUMO
PURPOSE: The purpose was to investigate stress distribution among 4 different customized abutment types: titanium abutment (Ti), titanium hybrid-abutment-crown (Ti-Hybrid), zirconia abutment with titanium base (Zir-TiBase), and zirconia hybrid-abutment-crown with titanium base (Zir-Hybrid-TiBase). MATERIALS AND METHODS: To achieve this purpose, 4 types of abutment configurations were simulated. A static load of 200 N (vertical) and 100 N (oblique) were applied to the models. The volume average, maximum, and stress distribution of von Mises stress, including percentage difference, were analyzed with 3D finite element analysis. RESULTS: According to the volume average von Mises stress, the Ti and Zir-TiBase comparison group showed that the Zir-TiBase group dominantly generated the higher value at Ti-base (22.57 MPa) and screw (17.68 MPa). To evaluate the effect of the hybrid-abutment-crown on volume average von Mises stress by comparing the Ti-Hybrid and Zir-Hybrid-TiBase groups, it was revealed that the combination of abutment and crown in the Ti-Hybrid group generated the worst stress concentration at the screw (12.42 MPa), while in the Zir-Hybrid-TiBase group presented stress concentration at the implant (8.90 MPa). CONCLUSIONS: A titanium base improved stress distribution at implant in zirconia abutment with titanium base by absorbing stress itself. Customized titanium hybrid-abutment-crown and zirconia hybrid-abutment-crown with titanium base created concentrated stress at screw and implant; respectively. Both abutment types should be cautiously used and maintenanced regularly.
Assuntos
Implantes Dentários , Titânio , Coroas , Dente Suporte , Projeto do Implante Dentário-Pivô , Análise do Estresse Dentário , Análise de Elementos Finitos , Estresse Mecânico , ZircônioRESUMO
Saliva is secreted from the acinar cells of the salivary glands, using mechanisms that are similar to other types of water-transporting epithelial cells. Using a combination of theoretical and experimental techniques, over the past 20 years we have continually developed and modified a quantitative model of saliva secretion, and how it is controlled by the dynamics of intracellular calcium. However, over approximately the past 5 years there have been significant developments both in our understanding of the underlying mechanisms and in the way these mechanisms should best be modelled. Here, we review the traditional understanding of how saliva is secreted, and describe how our work has suggested important modifications to this traditional view. We end with a brief description of the most recent data from living animals and discuss how this is now contributing to yet another iteration of model construction and experimental investigation.
Assuntos
Células Acinares , Cálcio , Modelos Biológicos , Água , Células Acinares/metabolismo , Cálcio/metabolismo , Humanos , Saliva/metabolismo , Água/metabolismoRESUMO
PURPOSE: The occiput-axis crossing translaminar screw (C2LAM) fixation technique can help avoid vertebral injury, while the inclusion of offset connectors can facilitate implantation. This three-dimensional finite element (FE) study compared the stability of C2LAM using offset connectors (C2LAM + OF) with other methods. MATERIALS AND METHODS: Occipital and cervical spine computed tomography images of a healthy 30-year-old man were selected to build the FE model. Four internal fixation instruments including occiput plate-C2 pedicle (C2P) and pars (C2Pars) screws, as well as C2LAM and C2LAM + OF were applied consecutively to the model respectively to establish four new models, which were subjected to all states of motion and physiological loads to simulate normal movement, including the four kinds of basic activities of human such as flexion, extension, lateral bending, and axial rotation. Physiological measures and comparison included the range of motion (ROM) and stress distribution in the model. RESULTS: ROM between the fixation techniques was comparable, and the stability of the C2LAM + OF fixation technique was similar to that of C2P. Screw entry points, offset connectors and rods were the main stress distribution regions in the C2LAM + OF system. The mean von Mises stress of the inner wall was significantly smaller than that of the outer wall in flexion, extension, and rotation (p < 0.05); however, lateral bending was comparable, indicating a relatively small risk of damage to the inner wall. CONCLUSIONS: The results of this study indicate that the C2LAM + OF fusion technique can provide sufficient stability and can be used as an alternative to C2P under special circumstances.
RESUMO
BACKGROUND: Plate dentures cannot be easily modified after fabrication; therefore, the sites and magnitude of relief must be effectively assessed at the time of fabrication. However, a considerable variation exists in the magnitude of optimal relief and relief range, and there are no guidelines that present these clearly, leading the dentists to decide subjectively. Thus, this study aims to develop an optimal relief method to improve the stress bearing capacity of the palatal mucosa. METHODS: The objective of this study, namely, the borderline, was set in steps. A three-dimensional finite element model for the pseudopalatal plate was created and used to evaluate the changes in stress distribution in the palatal mucosa due to the selective relief of stresses above the borderline. The resulting data were used to develop the optimal relief method. RESULTS: In the relief model with a borderline of 0.04 MPa or higher, the distribution volume at which a high stress of 0.20 MPa or higher is generated was approximately 800% of that with the no-relief model, and in the relief model with a borderline of 0.06 MPa or higher, the respective ratio was approximately 280%. On the other hand, the relief models with a borderline of 0.14 MPa or higher were approximately 60%. In the mid-palatal relief model, the distribution volume at which a stress of 0.20 MPa or higher was generated was 180% of that in the relief model. CONCLUSIONS: The supportive strength of plates can be increased by selectively applying optimal relief rather than standard relief, allowing for easier and more effective plate-denture treatment.
Assuntos
Placas Ósseas , Palato , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Estresse MecânicoRESUMO
This study aims to elucidate the biomechanical effects of combined loading of maxillary anterior and posterior implants using the sliding method on en-masse retraction of the anterior teeth and to quantify the loading ratio (LR) of anterior and posterior implants to achieve controlled retraction of the maxillary anterior teeth. A three-dimensional finite element model of the maxilla-upper dentition appliance was constructed. Implants were placed on the distal (A) and mesial (B) sides of the lateral incisors as well as on the mesial (C) side of the first molar and different amounts of force were loaded between the implants using 2- or 5-mm traction hooks. The labiolingual movement of the anterior teeth was recorded and the relationship between the LR of the implants and the movement of the central incisors was evaluated. With 2-mm traction hooks, the central incisors exhibited a translation tendency during retraction at lower A/C and B/C LR and labial or lingual crown inclination at higher values. With 5-mm traction hooks, the central incisors, lateral incisors, and canine teeth exhibited a labial crown inclination. The results of this study suggest that 2-mm traction hooks can cause labial crown inclination, translation tendency during retraction, or lingual crown inclination of the central incisors due to alterations in the LR of the anterior and posterior implants. The central incisors only exhibited labial crown inclination during combined loading of the anterior and posterior implants when 5-mm traction hooks were used.
Assuntos
Procedimentos de Ancoragem Ortodôntica , Técnicas de Movimentação Dentária , Dente Canino , Análise de Elementos Finitos , Incisivo , MaxilaRESUMO
In this paper, a three-dimensional finite element analysis (3D-FEA) model for shear horizontal surface acoustic wave (SH-SAW) torque sensors is presented. Torque sensors play a significant role in various fields to ensure a reliable torque transmission in drivelines. Featured with the advantages of high propagation velocity, large Q-value, and good power capacity, SH-SAW based torque sensors are promising but very few studies have been carried out. In order to develop a successful sensor, understanding the characteristics of SH-SAWs produced on piezoelectric substrates and torque sensing modes is indispensable. Therefore, in this study, we first investigated the effect on the generation of waves when different Y-cut quartz substrates are engaged. Thereafter, analyses and comparisons, regarding the effect on the polarized displacement, wave guidance, and wave mode, were conducted for different configurations of wave-guide layer thickness to wavelength ratios (hlayer/λ) and materials. Results show that Y-cut quartz at an angle close to 36° with a gold (Au) layer varying from hAu/λ = 0.02 to 0.03 thickness could be the most effective configuration for the excitation of SH-SAWs, compared to other combinations using platinum (Pt), titanium (Ti) and silicon dioxide (SiO2). Finally, based on the FEA SH-SAW torque sensor model configuring with a Y + 36° quartz substrate and 0.025 λ-thick gold layer, the relationship between the applied torque and sensed voltage was examined, which shows a perfect linearity demonstrating the performance of the sensors.
RESUMO
OBJECTIVE: To design minimal invasive screw on posterior pelvic ring and perform threedimensional finite element analysis based on a pelvis finite element model. METHODS: We measured the pelvic anatomical data of 20 healthy volunteers and identified potential designs for minimal invasive screw on posterior pelvic ring. A finite element model of pelvis was then established. Threedimensional finite element analyses were performed under static and dynamic mechanical loading,respectively. RESULTS: Three screw tracks on ilium (A,B and C) were identified based on a threedimensional reconstruction of pelvis. Nail track B and C had greater length and width,but shorter distance between nailing and soft tissue compared with nail track A. Static loading under an external rotation load of 500 N generated a maximum Mises Von stress of 582.05 Pa and sacral iliac complex of 107.38 Pa. The greatest strain was located at the articular cartilage on the side of the nail,followed by lateral sacral joint cartilage and symphysis pubis. The largest displacement was located at the ilium on the side of the nail,with a gradient decrease to the opposite side. The largest displacement of the anterior superior iliac spine was 0.35 cm on the side of the nail. The dynamic loading identified displacement of the anterior superior iliac spine with 1.5 mm in Z axis,1.8 mm in X axis and -0.2 mm in Y axis; and displacement of the pubic bone with 0.8 mm in Z axis,1.0 mm in X axis and 0.03 mm in Y axis. The maximum displacement appeared along the impact direction: Y axis. Relatively large equivalent stress was found in pubis and ischium,anterior superior iliac spine,sacrum,acetabular that are prone to fracture. With increased impact force,the stress of pelvis increased over time. The maximum impact force,stress and displacement of the pelvis occurred at 10 ms when peak force was reached. Under the impact of 4 000 N and 5 000 N,the bone was subject to a stress level of over 200 MPa,exceeding its average yield strength,which suggests a possibility of pelvic fracture. CONCLUSION: Taking B/C as a main screw track and A as an auxiliary screw track is a reasonable choice. The pelvic finite element model lays a foundation for further studies into sacral fracture and design of screw tracks.
Assuntos
Parafusos Ósseos , Ossos Pélvicos/anatomia & histologia , Fenômenos Biomecânicos , Análise de Elementos Finitos , Fixação Interna de Fraturas , Humanos , SacroRESUMO
AIM: By using the finite element method (FEM), this study aimed to evaluate the effect of different corticotomy formats on the distribution and magnitude of stress on the periodontal ligament (PDL) during retraction of the maxillary canine. MATERIALS AND METHODS: A geometric model of the left hemi-jaw was created from computed tomography scan images of a dry human skull and loads were administered during distalization movement of the canine. Three trials were performed: (1) without corticotomy, (2) box-shaped corticotomy and perforations in the cortical bone of the canine (CVC) and (3) CVC and circular-shaped corticotomy in the cortical bone of the edentulous space of the first premolar. RESULTS: There was no difference in stress distribution among the different corticotomy formats. CONCLUSION: Different corticotomy formats used to accelerate orthodontic tooth movement did not affect stress distribution in the PDL during canine retraction. CLINICAL SIGNIFICANCE: From a mechanical perspective, the present study showed that the stress distribution on the PDL during canine retraction was similar in all the corticotomy formats. When using the Andrews T2 bracket, the PDL presented the highest levels of stress in the middle third of the PDL, suggesting that the force was near the center of resistance. Also, as bone weakening by corticotomies did not influence stress distribution, the surgical procedure could be simplified to a less aggressive one, focusing more on inflammatory cellular stimulation than on bone resistance. A simpler surgical act could also be performed by most orthodontists in their practices, enhancing postoperative response and reducing patient costs.
Assuntos
Dente Canino , Análise de Elementos Finitos , Maxila , Ligamento Periodontal , Humanos , Modelos Anatômicos , Técnicas de Movimentação DentáriaRESUMO
INTRODUCTION: From the point of dental practice, the restoration of endodontically treated teeth has become an important aspect as it involves a range of treatment options of variable complexity. Restoring teeth with insufficient coronal tooth structure, it is always indicated to use the post to retain a core for definitive restoration. Fiber post has a modulus of elasticity in analogs to dentin structure, thus reducing the stress areas at the dowel dentin interface. However, the only material that can substantiate all these properties can be none other than dentin itself. MATERIALS AND METHODOLOGY: Three-dimensional (3D) models of the maxillary central incisor were developed incorporating all the nonlinearities. Continuum 3D elements were used in three dimensions. Maxillary central incisor was laser scanned, duplicated with the help of reverse engineering into STL format, and it was converted into 3D model for finite element analysis (FEA). For the model, fixed boundary conditions were applied at the outer bone, while 100 N static vertical occlusal loads were prescribed at 135° on the loading component of the simulated tooth. The stress distribution was evaluated using dentin and fiber post with prescribed materials, loading and boundary conditions in endontically treated teeth by 3D FEA. RESULTS: The analysis for von Misses stress for dentin post showed that the stress in the dentin post at the cervical area was 127 MPa. The displacement in the dentin post was <0.025 mm. Von Misses stress for the fiber post at the cervical area was approximately 182 MPa and the displacement was <0.035 mm. CONCLUSION: The FEA results showed that the stress in the cervical area of the dentin was more for fiber post when compared to dentin post, and maximum displacement values were less for dentin post in comparison to fiber post.
RESUMO
Background: The band and loop space maintainer is used to maintain the missing space of deciduous molars which are lost early. When the second deciduous molar is lost prematurely, the stress on the first permanent molar during different degrees of development may vary when it is the abutment. The design and use of the space maintainer may also lead to damage of the loop. The purpose of this article is to use the finite element method to study the stress on the first permanent molar and the loop with or without occlusal contact, with the first permanent molar of four different degrees of development serving as the abutment. We aimed to guide the clinical design and use of the space maintainer. Methods: We developed finite element models of the mandibular first permanent molar and the band and loop space maintainer, and simulated alveolar bone, periodontal ligament (PDL), enamel and dentin. The four developmental stages were 1/2 (I), 2/3 (II), 3/4 (III) and full development (IV). Ansys Workbench was used to analyze the effects of root development and occlusal contact between the loop and the opposite jaw on abutment teeth and the loop. Abutment teeth were statically loaded vertically and obliquely with a force of 70 N. The loop was statically loaded vertically with a force of 14 N. The stress on all structures and the displacement trends of the loop were calculated. Results: The stress on enamel, dentin, PDL and alveolar bone were similar, and the concentration was consistent. But if there was occlusal contact, the loop produced maximum displacement at the near middle edge of contact with the anterior teeth. When the loop was in occlusal contact with the opposing occlusal tooth, the peak value of the equivalent stress on the space maintainer under vertical load was: group I > group IV > group III > group II, and the maximum principal stress peak change was: group I > group III > group II > group IV. The change of the equivalent stress peak value of the loop under oblique load was: group I > group III > group IV > group II, and the maximum principal stress peak change was: group III > group I > group II > group IV. When the loop was not in occlusal contact with the opposing occlusal tooth, the peak value of the equivalent stress on the space maintainer under vertical load was: group IV > group I > group II > group III, and the maximum principal stress peak change was: group IV > group I > group II > group III. The change of the equivalent stress peak value of the space maintainer under oblique load was: group I > group IV > group II > group III, and the maximum principal stress peak change was: group I > group IV > group II > group III. Conclusions: Our results suggested that whenever possible, choosing the teeth with nearly complete root development as the abutment of the space maintainer is advisable. The design and use of the band and loop space maintainer should avoid occlusal contact with the occlusal teeth to prevent deformation of the loop.
Assuntos
Força de Mordida , Análise de Elementos Finitos , Mandíbula , Dente Molar , Dente Molar/fisiologia , Humanos , Mandíbula/fisiologia , Estresse Mecânico , Mastigação/fisiologia , Análise do Estresse Dentário/métodos , Ligamento Periodontal/fisiologia , Ligamento Periodontal/crescimento & desenvolvimentoRESUMO
This study aimed to evaluate the biomechanical compatibility of a modular hemipelvic prosthesis by comparing stress distributions between an implanted pelvis and a healthy pelvis. Finite element analysis was used to simulate bilateral standing loads on both models, analyzing critical regions such as the sacroiliac joints, iliac crest, acetabulum, and prosthesis connection points. Six models with varied displacements of the hip joint rotational center were also introduced to assess the impact of deviations on stress distribution. The implanted pelvis had a stress distribution closely matching that of the intact pelvis, indicating that the prosthesis design maintained the biomechanical integrity of the pelvis. Stress patterns in displacement models with deviations of less than 10 mm were similar to the standard model, with only minor changes in stress magnitude. However, backward, upward, and inward deviations resulted in stress concentrations, particularly in the prosthesis connection points, increasing the likelihood of mechanical failure. The modular hemipelvic prosthesis demonstrated good biomechanical compatibility with minimal impact on pelvic stress distribution, even with moderate deviations in the hip joint's rotational center; outward, forward, and downward displacements are preferable to minimize stress concentration and prevent implant failure in cases where minor deviations in the rotational center are unavoidable during surgery.