Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros

País como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(3): 166, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38388725

RESUMO

OBJECTIVE: The aim of this study was to evaluate six files on the pericervical dentin (PCD) and the smallest dentin thickness zones (SDTZ) in mesial root canals of mandibular molars. MATERIALS AND METHODS: Sixty mandibular molars with two mesial canals and Vertucci configuration were aleatory allocated in 6 experimental groups of 10 molars and 20 root canals. Specimens were scanned before instrumentation using the SkyScan 1275 (Bruker microCT, Kontich, Belgium). Group 1 was treated with WaveOne Gold (WG), group 2 with Reciproc Blue (RB), group 3 with TRUShape (TS), group 4 with XP-endo Shaper (XP), group 5 with iRace (IR), and group 6 with TruNatomy (TN). After instrumentation, the molars were scanned again and the images recorded were reconstructed with the NRecon v.1.7 (Bruker micro-CT) and analyzed with CTAn v.1.20.8 software (Bruker micro-CT) quantifying the changes produced in the surface, volume, structure thickness, SMI, and centroids at the Pericervical Dentin area of the root canals (PCD) located from the root canal orifices at the floor of the pulp chamber to 4 mm in the apical direction, and the changes in the Smallest Dentin Thickness Zones (SDTZ) located (from the furcation to 4 mm and 7 mm in the apical direction. The data obtained were compared using Wilcoxon and ANOVA with a 5% significance level. RESULTS: XP and TN were similar in all the parameters (P >.05) at the PCD, but TN showed significant differences from WG, RB, TS, and IR (P <.05), while XP showed significant differences from WG (P <.05) in volume, surface, and structure thickness. Regarding the changes in the SDTZ, the amount of dentin removed was similar between the groups in both canals at the middle 1/3, at the cervical 1/3 for MB canals, and in ML canals for RB, TS, XP, IR, and TN (P>.05). The action of WG was significantly different from that of XP and TN in the cervical 1/3 of the ML canal (P <.05). CONCLUSIONS: XP and TN rotatory files with small taper and volume maintained better with minor changes at the PCD and SDTZ, while WG reciprocation file produced the largest change. All the files were maintained centered at the PCD, and their performances were safe with a minimal thickness higher 0.5 mm at the SDTZ, and without risk of perforation. TRIAL REGISTRATION: No clinical trials were indicated in this study. CLINICAL RELEVANCE: The choice of endodontic files is a relevant factor in the conservative performance of root canal treatments.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Microtomografia por Raio-X , Dente Molar/diagnóstico por imagem , Ouro , Dentina/diagnóstico por imagem
2.
BMC Oral Health ; 23(1): 780, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37875946

RESUMO

BACKGROUND: This study aimed to compare the shaping ability of different instruments, TruNatomy Glider (TRN-G), WaveOne Gold Glider (WOG-G), and ProGlider (Pro-G) using micro-computed tomography (micro-CT). METHODS: The mesial canals of 27 mandibular molars with two separate mesial canals and moderate curvature were included in this study [n = 27 mesiobuccal (MB) and mesiolingual (ML) root canal]. According to the manufacturer's instructions, the glide path was created with TRN-G, WOG-G, and Pro-G glide path instruments (n = 9 MB and ML root canal in each group). Micro-CT scanning was performed before and after preparation. Mesiodistal (MD) and buccolingual (BL) transportation and the centering ratio were measured at three levels within the canal (3, 5 and 7 mm). A three-way robust ANOVA was used to compare the parameters. RESULTS: TRN-G showed significantly greater transportation in the MD direction than the other instruments throughout the root canal (overall root canal) (p < 0.05). The best centering ability in the BL direction was shown by the WOG-G, regardless of level within the canal and canal distinction (MB vs. ML) (p < 0.05). There was no significant difference between groups according to the level within the canal and canal parameters (p > 0.05). Whether the root canal was MB or ML did not affect centering or transportation (p > 0.05). CONCLUSIONS: Glide path instruments can be used to shape moderately curved canals with minimal apical transportation and better centering ability. All three tested glide path files can used safely before the shaping file.


Assuntos
Preparo de Canal Radicular , Raiz Dentária , Humanos , Microtomografia por Raio-X/métodos , Tratamento do Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Desenho de Equipamento
3.
J Contemp Dent Pract ; 24(5): 337-341, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38149812

RESUMO

AIM: This in vitro study aimed to compare and evaluate the resistance to cyclic fatigue of a newly developed glide path file in a simulated double curvature canal in a cyclic fatigue-testing machine. METHODS: In this in vitro study, a static cyclic fatigue-testing machine with a simulated double curve was created and the samples were divided into the following three groups: Group I-HyFlex EDM; group II-TruNatomy file; and group III-Aurum G files and each instrument is continued to rotate in the canal and a number of cycles to failure (NCF) was calculated and Fractographic analysis was done using scanning electron microscope (SEM), and the results were statistically analyzed. RESULTS: Statistical analysis was done using parametric methods one-way analysis of variance (ANOVA) shows statistical significance between groups and then Tukey's HSD post hoc tests were used for multiple pairwise comparisons. TruNatomy glide path files had the highest cyclic fatigue resistance when compared to HyFlex EDM and Aurum G files. CONCLUSION: The selection of file systems in cleaning and shaping protocols is an enigma to endodontics. From the results of this study, it can be concluded that TruNatomy files had higher cyclic fatigue resistance than other glide path files are canals with double curvature, hence it is suitable for usage in root canals with extreme curvature. CLINICAL SIGNIFICANCE: The selection of file systems in cleaning and shaping protocols is an enigma to endodontics. This in vitro study explored the selection protocols for the execution of root canal preparation. Heat treatment of nickel-titanium (NiTi) endodontic files had improved the cyclic fatigue resistance significantly enhancing the clinical life of file systems.


Assuntos
Projetos de Pesquisa , Titânio , Preparo de Canal Radicular , Instrumentos Odontológicos , Falha de Equipamento
4.
J Contemp Dent Pract ; 24(4): 221-227, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37469260

RESUMO

AIM: The purpose of this study was to evaluate and compare the canal transportation tendencies and centering ability of the TruNatomy shaper (TN) and XP-endo shaper (XPS) rotary systems in oval-shaped canals with moderate root curvature (15°-25°), using cone-beam computed tomography (CBCT) imaging. MATERIALS AND METHODS: Sixty single-rooted permanent human teeth were chosen after considering the inclusion and exclusion criteria. The teeth were divided into two groups (n = 30). The test group was instrumented with TN files and the other with XPS according to manufacturer's instructions. CBCT images were taken before and after instrumentation to record the root canal distances from mesial, distal, buccal, and lingual borders of the root at 3, 5, and 7 mm distances from the root apex using a specific formula. Statistical analysis was done using the Statistical Package for the Social Sciences software program, version 20.0. The data were analyzed using the unpaired t test. RESULTS: Both TN and XPS were safe for use in oval-shaped canals with moderate root curvature. However, the XPS showed higher buccolingual transportation as compared with TN at 3 mm from the apex and higher mesiodistal transportation at 3 and 5 mm levels from the apex as compared with TN. CONCLUSION: Canal transportation has been detected in both systems; however, the values obtained were within the safe range (<0.3 mm). Overall, no significant difference was observed between TN and XPS (p > 0.05) in their canal transportation tendencies and centering ability. CLINICAL SIGNIFICANCE: The study assesses the canal centering and transportation tendencies of the recently launched TN rotary system in extracted teeth with a combination of morphologies. The findings of the study are significant clinically as minimum transportation of the canal, minimal dentin removal, efficient disinfection, and three-dimensional obturation of the root canal are considered important factors in deciding the prognosis of endodontic therapy.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Humanos , Cavidade Pulpar/diagnóstico por imagem , Preparo de Canal Radicular/métodos , Dente Molar , Desenho de Equipamento , Raiz Dentária/diagnóstico por imagem
5.
J Contemp Dent Pract ; 23(9): 944-952, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37283003

RESUMO

AIM: This narrative review aims to explore and elicit the newer endodontic file systems used for root canal treatments. BACKGROUND: The primary goals of endodontic therapy continue to be the mechanical enlargement and shaping of the intricate endodontic root canal systems to aid in disinfection. Nowadays endodontists have access to a wide range of endodontic file systems for root canal preparations with various design characteristics and benefits. REVIEW RESULTS: ProTaper Ultimate (PTU) files' tip have a triangular convex cross-section, an offset mass of rotating design, a maximum flute diameter of 1.0 mm, and are constructed of gold wire, hence, commonly applied in conditions with restricted accessibility or an extremely curved canal. TruNatomyhas advantages over other cutting-edge file systems like maximum flute diameter of the corona, reduced distance between active cutting flutes, and shorter handles in comparison to SX instruments. In comparison to PTU files, ProTaper Gold (PTG) files are noticeably more elastic and fatigue-resistant. Compared to files in the F1-F3 range, size S1 and S2 files have a significantly longer fatigue life. MicroMega One RECI is more resistant to cyclic fatigue because of its heat treatment and reciprocating action and the C-wire heat treatment of the former gives it flexibility and controlled memory, enabling the prebending of the file. The RECIPROC blue demonstrated enhanced flexibility, increased fatigue resistance, and lower microhardness while maintaining the same surface qualities. CONCLUSION: As per the necessity and requirement on case to case basis, every endodontic file system has advantages and disadvantages as mentioned in this narrative review. According to the need, an endodontist can select the file system which is required specifically. Although several studies are comparing these various systems in the literature, this narrative review aims to give the clinician a summary of some recently launched endodontic rotary file systems available in the market and their clinical uses. CLINICAL SIGNIFICANCE: As per the priority and need of the case, whether removal and extrusion of debris, reduction of micro-organisms, keeping canal anatomy, and cutting efficiency, a specific required file system can be utilized.


Assuntos
Instrumentos Odontológicos , Endodontia , Tratamento do Canal Radicular , Tratamento do Canal Radicular/instrumentação , Endodontia/instrumentação , Desenho de Equipamento
6.
BMC Oral Health ; 21(1): 533, 2021 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-34656099

RESUMO

BACKGROUND: In root canal preparations, it is important to maintain the original canal shape. However, it is difficult to accomplish this, especially due to the complex canal anatomy. This study aimed to compare the shaping ability of the ProTaper GOLD, WaveOne GOLD, and newly developed TruNatomy in simulated S-shaped canals. METHODS: The root canals of 60 S-shaped resin blocks were dyed using ink and photographed. The blocks were then randomly divided into three groups: group ProTaper GOLD (n = 20), WaveOne GOLD (n = 20), and TruNatomy (n = 20). The simulated canals were instrumented according to the NiTi file system and photographed again after being dyed with red ink. The pre- and post-preparation images were superimposed, and the amount of resin removed from both the mesial and distal sides of the canal measured up to 9 mm from the apical terminus, with a 1 mm increment. The preparation time was also calculated. A paired t-test was used to determine the degree of deviation at different levels within the groups. To compare the degree of transportation at different levels between the groups, one-way ANOVA and Kruskal-Wallis tests were performed according to the normality. RESULTS: TruNatomy showed a significant deviation between the mesial and distal sides of the canal only in the coronal area at 6, 7, 8, and 9 mm levels of the canal (p < 0.05). When comparing the amount of transportation in the 3 groups at 9 different levels, TruNatomy showed significantly less canal transportation than the other groups at the 3-and 5-mm levels of the canal (p < 0.05), while ProTaper GOLD showed the largest amount of transportation in the apical curved area at the 2 and 3 mm levels (p < 0.05). TruNatomy removed less resin than other groups in all sections (p < 0.05), while ProTaper GOLD removed slightly more resin than WaveOne GOLD; however, there was no significant difference (p = 0.043). Shaping time was the least for TruNatomy, followed by the WaveOne GOLD and ProTaper GOLD (p < 0.05). CONCLUSIONS: TruNatomy maintained the original apical canal curvature in S-shaped curved canals better than ProTaper GOLD and WaveOne GOLD.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Desenho de Equipamento , Humanos
7.
J Contemp Dent Pract ; 22(2): 117-121, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34257168

RESUMO

AIM: This study was carried out to compare canal transportation in three new rotary file systems, namely TruNatomy, ProTaper Gold, and Hyflex Electric Discharge Machining file system, using cone-beam computed tomography. MATERIALS AND METHODS: The study was conducted on 105 extracted teeth consisting of 60 extracted mandibular first molars and 45 mandibular second premolars involving the mesiolingual canal of mandibular first molar and the root canal of second premolar. The teeth were randomly divided into three groups of 35 out of which each group consisted of 20 mandibular first molars and 15 mandibular second premolars. The TruNatomy rotary file was used in group I, ProTaper Gold was used in group II, and Hyflex Electric Discharge Machining was used in group III. Cone-beam computed tomography scan images were obtained both before and after instrumentation. Changes caused by preparation in the coronal, middle, and apical thirds were determined on cone-beam computed tomography scans and analyzed using the Kruskal-Wallis test at p ≤ 0.05 level of significance. RESULTS: TruNatomy showed least amount of canal transportation as compared with other two file systems at all the three levels of canals. ProTaper Gold showed maximum amount of canal transportation as compared with other two file systems at all the three levels of canals. The Hyflex EDM rotary file system showed transportation, which was more than the TruNatomy file system while it was less than that of ProTaper Gold. The difference was statically significant at the middle one-third level (p = 0.03) and at the coronal level (p = 0.02). CONCLUSION: The TruNatomy system has least amount of canal transportation as compared with ProTaper Gold and Hyflex EDM system. With potential to preserve tooth structure, this file has an added advantage over other rotary file systems. CLINICAL SIGNIFICANCE: The TruNatomy file system has been recently introduced with good cyclic fatigue resistance. It is necessary to evaluate the root canal transportation caused by the TruNatomy file.


Assuntos
Ouro , Preparo de Canal Radicular , Tomografia Computadorizada de Feixe Cônico , Cavidade Pulpar , Desenho de Equipamento , Humanos , Alta do Paciente
8.
J Contemp Dent Pract ; 22(9): 1055-1059, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35000952

RESUMO

AIM: This study investigated the performance of supplementary three single-file systems for eliminating root filling residue from oval-shaped canals utilizing cone-beam computed tomography (CBCT). MATERIALS AND METHODS: Thirty single-rooted human mandibular premolars with oval-shaped canals were chosen. After decoronation and working length determination, ProTaper Universal (PTUR) rotary files were used to prepare canals up to F3. Irrigation was fulfilled by 2.5% sodium hypochlorite (NaOCl), 17% ethylenediaminetetraacetic acid (EDTA), and lastly distilled water. By utilizing the lateral compaction technique, canals were filled by gutta-percha and Endosequence BC Sealer. The PTUR retreatment system (D1, D2, and D3) eliminated the primary filling material sequentially. Subsequently, specimens were categorized into three groups at random: group I: WaveOne Gold (WOG) primary file, group II: TruNatomy (TRN) medium file, and group III: XP-endo Finisher R (XPF-R). The volume of residual left from filling material was quantified utilizing CBCT imaging before and after the supplementary retreatment. Statistical analyses were done by one-way analysis of variance (ANOVA) and Tukey's test at a 5% significance level. RESULTS: The volume of removed root filling after using XPF-R was significantly higher than using WOG in all sections and TRN in the coronal third, while nonsignificantly higher than using TRN in the apical and middle. CONCLUSION: XPF-R as a supplementary technique revealed the highest percentage reduction of root filling material (73.13%) in comparison with the other systems (37.39% WOG and 44.16% TRN) in oval-shaped canals. CLINICAL SIGNIFICANCE: Neither one of the methods and tools used to remove filling material from oval-shaped root canals is perfectly efficient. The performance of supplementary techniques using contemporary single-file systems improves the cleaning and reshaping of root canal space that permits a proper disinfection to optimize the outcome of retreatment option.


Assuntos
Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Guta-Percha , Humanos , Retratamento , Materiais Restauradores do Canal Radicular/uso terapêutico , Preparo de Canal Radicular
9.
J Contemp Dent Pract ; 22(11): 1243-1249, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35343448

RESUMO

AIM AND OBJECTIVE: To compare and analyze the cyclic fatigue resistance of novel TruNatomy files against the conventionally used rotary files and reciprocating files in a simulated canal system with curvatures in the middle, apical portions root, and S-shaped canal employing scanning electron microscopy. MATERIALS AND METHODS: Endodontic files tested in the study include ProTaper, HyFlex EDM, Reciproc blue, and TruNatomy files operated in a simulated root canal system. A total of 96 files were employed in this study. They were categorized into four groups. Group 1 employed 24 TruNatomy files, group 2 employed 24 ProTaper gold files, group 3 employed 24 HyFlex EDM files, and group 4 employed 24 Reciproc blue files. All the groups employed eight files each under three subgroups namely A, B, and C representing middle, apical, and double curvatures, respectively. Artificial grooves were incorporated in the stainless steel blocks having three different curvatures. All the file systems were operated with a torque-controlled electric motor. The files were engaged in the artificial canal until the occurrence of fracture. The time required for the fracture was noted. Length of fractured tip was measured using the digital Vernier caliper. The number of cycles of failure (NCF) was calculated. The fractured parts were subjected to scanning electron microscope to analyze the mode of fracture. RESULTS: TruNatomy files had the highest mean NCF values of 588.01 in middle curvature, 1,321 in apical curvature, and 642.5 in S-shaped curvature HyFlex EDM and Reciproc blue file system exhibited comparable cyclic fatigue resistance among them. ProTaper gold file system exhibited least mean NCF values of 158.13 in the middle, 196.5 in the apical curvature, and 116.88 in the S-shaped canal system. Middle portion fractured first than the apical curvature. The mean length of fractured segments was found to be insignificant among the experimental study groups tested. CONCLUSION: All the file systems employed in the study had good cyclic fatigue resistance while TruNatomy files had the highest cyclic fatigue resistance while HyFlex EDM and Reciproc blue had comparable fatigue resistance. ProTaper gold file system had the least fatigue resistance at different radius of curvature in the simulated canal system in the apical and middle portions and S-shaped root canal. CLINICAL SIGNIFICANCE: The selection of file systems in cleaning and shaping protocols is an enigma to the endodontics. This in vitro study explored the selection protocols for the execution of root canal preparation. Heat treatment of nickel-titanium (NiTi) endodontic files had improved the cyclic fatigue résistance significantly enhancing the clinical life of file systems.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular , Ligas Dentárias , Falha de Equipamento , Teste de Materiais
10.
BMC Oral Health ; 20(1): 38, 2020 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-32019522

RESUMO

BACKGROUND: The purpose of this study was to compare the cyclic fatigue resistance of newly developed TruNatomy instruments (TRN) in single and double (S-shaped) curvature canals with HyFlex CM (HCM), Vortex Blue (VB) and RaCe (RC) instruments. METHODS: Size 20/.04 taper and size 25/0.04 of HCM, VB and RC were used. For TRN instruments, size 20/.04 taper (small) and size 26/.04 taper (prime) were used. The instruments were tested in artificial canals with double curvature (coronal curve; 60° curvature, 5 mm radius and apical curve; 70° curvature and 2 mm radius) and single curvature (60° curvature, 5 mm radius). The number of cycles to failure (NCF) was recorded. Data were statistically analyzed by Kruskal-Wallis and Dunn's multiple comparison tests. Weibull analysis was performed on NCF data. Statistical significant was set at p < 0.05. RESULTS: TRN and HCM revealed higher NCF compared with the other instruments for both tested sizes in single and double curvature canals (p < 0.05). TRN and HCM showed no statistically significant difference in the NCF (p > 0.05). The probability of survival was higher for HCM and TRN instruments than VB and RC instruments. CONCLUSIONS: HCM and TRN instruments were more resistant to cyclic fatigue than VB and RC instruments in single and double curvature canals. HCM and TRN instruments were anticipated to survive with higher number of cycles than the other tested instruments. RC instrument had the lowest fatigue resistance than the other instruments.


Assuntos
Ligas Dentárias , Instrumentos Odontológicos , Cavidade Pulpar/anatomia & histologia , Níquel , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Titânio , Análise do Estresse Dentário , Desenho de Equipamento , Falha de Equipamento , Humanos , Teste de Materiais
11.
J Conserv Dent Endod ; 27(1): 95-99, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38389747

RESUMO

Aims: The aim of this in vitro study was to compare the cyclic fatigue resistance of three different endodontic nickel-titanium rotary instruments using a dynamic testing device. Materials and Methods: Ten files each of ProTaper Gold (PG), Hyflex Electro-discharge Machining (HEDM), and TruNatomy (TN) were tested in a custom-fabricated dynamic cyclic fatigue testing device at 60° curvature having a radius of curvature of 5 mm. The number of cycles to the fracture (NCF) of each instrument was calculated and three continuous groups were compared by the Kruskal-Wallis test and Dunn post hoc test was used for pairwise comparison. Results: Cyclic fatigue resistance of HEDM was the highest, followed by TN. PG had the lowest among the three. Conclusion: Within the limitations of the present in vitro results, it can be concluded that HEDM files appeared to be suitable for shaping complex canals with the greater number of cycles before it fractures.

12.
Cureus ; 16(2): e53506, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38440012

RESUMO

INTRODUCTION: Biomechanical preparation has gotten easier over time with the development of nickel-titanium (NiTi) rotary instruments. Despite their benefits, research has shown that these files frequently result in microcracks in the root canal dentin, which can fracture the roots. Such mishaps should be prevented, as they compromise the integrity of the root and reduce the long-term survival of endodontically treated teeth. MATERIALS AND METHODS: This study was conducted at Government Dental College and Hospital, Patiala, Punjab, India. Eighty permanent mandibular premolar teeth were included. All the roots were inspected for any pre-existing cracks or craze lines under a stereomicroscope. The teeth were decoronated and then divided into four groups (n = 20): Group I: TruNatomy, Group II: Neoendo Flex, Group III: ProTaper Gold, and Group IV: 2Shape. The samples were instrumented according to the group to which they belonged. The roots were then sectioned horizontally at 3 mm and 6 mm from the apex and examined under a stereomicroscope at 40x for the presence of microcracks. RESULTS: The data were analyzed using the IBM SPSS Statistics for Windows, version 26 (released 2019; IBM Corp., Armonk, New York, United States). A chi-square test was applied, and the level of significance was set at p < 0.05. The highest incidence of microcracks was associated with ProTaper Gold (65%), followed by Neoendo Flex (45%), TruNatomy (20%), and 2Shape (20%). CONCLUSION:  All rotary instruments resulted in dentinal damage. ProTaper Gold exhibited the highest frequency of dentin cracks. TruNatomy and 2Shape exhibited satisfactory results with minimal crack formation.

13.
Microsc Res Tech ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38813968

RESUMO

This study aims to compare the shaping ability of three systems using micro-computed tomography (micro-CT). Moderately-curved mesial canals of 36 mandibular molars were assigned to three groups (n = 24); Protaper Next (PTN, 0.25, 0.06), WaveOne Gold (WOG, 0.25, 0.07), TruNatomy (TRN, 0.25, 0.04), and instrumentation was performed. Pre- and post-micro-CT scans were obtained. Canal volume and surface, structure model index (SMI), centroid shift, canal transportation, and untouched canal were analyzed. One-way ANOVA and Student's t-test were used for statistics. There was no difference in SMI, centroid shift, and centering ability between the study groups (p > .05). Removed dentin and canal surface changes were lower in TRN, while untouched dentin walls were higher (p < .05). Cross-sections became more rounded (p < .05), but not significant between groups (p > .05). Considering the removed dentin by TRN, it can be used in critical dentin thickness, such as the danger zone (DZ). PTN, WOG, and WOG kept the original canal course similarly. Untouched dentin by TRN (41%) was wider than PTN and WOG, consequently, meticulous irrigation is recommended. TRN, which provides a controlled increase in canal volume, can be used in thin dentin such as the DZ, however, its use should be supported by copious irrigation and brushing considering the rate of untouched dentin walls. RESEARCH HIGHLIGHTS: TRN presented a higher untouched dentin wall compared to PTN and WOG. Canal volume and surface changes were the lowest in the TRN group. The centering abilities were similar in PTN, WOG, and TRN.

14.
J Conserv Dent Endod ; 27(1): 62-67, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38389738

RESUMO

Background: Recent innovations in the physical and mechanical features of endodontic file systems have diminished the prospect of stress generation and fracture risk in novel endodontic files. Aim: The purpose of this research was to comparatively evaluate the stress distribution of recently introduced endodontic rotary files with distinct features and metallurgy at three different levels of the root canal wall by finite element analysis. Materials and Methods: Forty endodontic files were used in this experiment after being inspected through a scanning electron microscope for any surface deformities. Based on their metallurgy and design, the scanned files were divided into four groups, each with 10 samples: Group A-2Shape files, Group B-F360, Group C-One Curve, and Group D-TruNatomy. To assess the mechanical behavior of these files, the stress produced by computer-aided models of these instruments on the dentinal wall of a simulated root canal was numerically analyzed using ANSYS® 15 Workbench finite element software. Results: A one-way ANOVA was used to assess all the raw data with post hoc Tukey analysis, the Shapiro-Wilk test, and Levene's test. F360 files exerted the maximum stress on the dentinal wall, while TruNatomy files exerted the least stress at all the distinct levels of dentinal walls. Conclusions: There was no statistically significant variation in the stress generated between the four groups. Therefore, it can be concluded that improvements in rotary file design and metallurgy have the potential to reduce the stress during canal shaping and the risk of instrument breakage during clinical use.

15.
Cureus ; 16(6): e61566, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38962599

RESUMO

AIM: The aim of this study was to evaluate and compare the dentin thickness of the mesio-buccal canal of the lower first molar after canal preparation with three different rotary file systems using cone beam computed tomography (CBCT). METHODOLOGY: TruNatomy (Dentsply Sirona, USA), 2Shape (Micro-Mega, France), and One Curve (Micro-Mega, France) were the three different rotary files that were employed. A total of 45 excised human permanent first mandibular molars were divided into Groups A (TruNatomy), B (2Shape), and C (One Curve) at random. To measure the residual dentin thickness at 3 mm, 5 mm, and 7 mm from the radiographic apex, the mesial root of the tooth was removed from the tooth, and a mesio-buccal canal was taken. Samples were mounted in clear acrylic resin and were subjected to a pre-instrumentation CBCT scan. The mesio-buccal canal was cleaned and shaped while maintaining the final mesio-buccal canal preparation of Group A - 26/0.04, Group B - 25/0.04, and Group C - 25/0.04. The samples were extensively irrigated with 3% sodium hypochlorite and 17% EDTA, and a post-instrumentation scan was performed on them. Statistics were used to determine the values from CBCT scans that were recorded for pre- and post-instrumentations. RESULTS: The results showed that Group A had the greatest drop in dentin thickness, followed by Group B and Group C. The change in dentin thickness was greatest at 3 mm and 7 mm. CONCLUSION: In contrast to TruNatomy and 2Shape rotary file systems, One Curve has the advantage of maintaining a tooth's thickness at 3 and 7 millimeters from the radiological apex. Since the TruNatomy file system removes more dentin than the other two combined, it should be used cautiously. Choosing the right instrument is crucial for cleaning and shaping during root canal preparation.

16.
J Pharm Bioallied Sci ; 16(Suppl 2): S1409-S1413, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38882834

RESUMO

Introduction: The longevity of an endodontically treated tooth depends on fracture resistance by preserving more remaining dentin thickness. The aim of this study is to determine which file system preserves more remaining dentin thickness. Materials and Methods: Protaper universal, M-two, Protaper Next, Trunatomy, I-Race and mandibular first premolar. The removed dentin thickness during instrumentation of each file system was noted by taking the difference of RDT of pre-instrumentation and post-instrumentation with the aid of CBCT. Results and Discussion: TRN [Group-4] shows the least aggressive cutting with maximal preservation of remaining dentin thickness at 3 mm and 6 mm from the apex at both mesiodistal and buccolingual dimensions. M-two [Group-2] shows maximum removed dentin thickness at 3 mm from the apex both mesiodistal dimension and buccolingual dimension. PTU [Group-1] shows maximum removed dentin thickness at 6 mm from the apex at mesiodistal dimension. M-two [Group-2] shows maximum removed dentin thickness at 6 mm from the apex at the buccolingual dimension. Conclusion: In this study, it is concluded that the Trunatomy file system preserves more remaining dentin thickness both mesiodistally and buccolingually both 3 mm and 6 mm from the apex.

17.
J Pharm Bioallied Sci ; 16(Suppl 1): S780-S782, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595610

RESUMO

Background: An important aspect of the preparation of the access cavity and biomechanical preparation of the root canal is to safeguard as much of the tooth's framework as possible without affecting access and visibility. Objectives: To compare the impact of the conservative design of access preparation and traditional design of access preparation in association with TruNatomy endodontic instrumentation and WaveOne Gold endodontic instrumentation on resistance to fracture by the design of a cavity for endodontic access using finite element analysis. Materials and Methods: Micro-CT radiographic images of 16 human first permanent molars of the mandible were included in the study to create representative finite element analysis computational models. Results: A significant reduction in load for failure after endodontic preparation was observed in TDAP subcategories as compared to specimens with CDAP. However, the reduction in load for failure was comparable in both endodontic instrument systems within the CDAP and TDAP. Conclusion: A significant reduction in load for failure after endodontic preparation was observed in the traditional design of access preparation subcategories as compared to specimens with the conventional design of access preparation.

18.
J Conserv Dent Endod ; 27(3): 268-273, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38634036

RESUMO

Background: Several designs of access cavity have been evolved in the recent past with the concept of minimal tooth tissue removal which would improve the root canal treated teeth fracture resistance. Aim: To investigate the effect of conservative design access cavity during the instrumentation of maxillary molar root canals. Materials and Methods: Eighty noncarious maxillary molars were assigned to the traditional and conservative access groups (n = 40 each). After designated access preparations, the teeth were immersed in Lugols's solution for staining the pulp tissue. Root canal instrumentation was performed with TruNatomy file system. Pre- and postinstrumentation nano-computed tomography (CT) images were taken and reconstructed using CT-An software. Root canals volumetric analysis was done with CT-Vol software. The analysis of the data was dealt with Shapiro-Wilk test and independent t-test. Results: The volume of pulp canal space before and after instrumentation changed significantly between the traditional and conservative access design groups, according to an independent t-test. In comparison, the mean volume of dentin removed was much larger in the TAC group (P = 0.0016). The independent t-test manifests difference significantly between traditional endodontic access cavity (TAC) and conservative access cavity (CAC) with percentage of unprepared canal walls. The mean percentage of unprepared area was significantly lesser in TAC group as compared to CAC group (P = 0.0022). Conclusion: The volume of dentin removed was greater in TAC than with the CAC design. The amount of untouched canal wall area was significantly higher in conservative access design than with the traditional access design group.

19.
J Conserv Dent Endod ; 26(5): 574-578, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38292357

RESUMO

Aims: The aim of this study was to evaluate the shaping ability following instrumentation with XP-endo Shaper (XPS), TruNatomy (TRN), and HyFlex CM (HCM) file system. Subjects and Methods: Fifty-four mesiobuccal canals of mandibular molars were selected and allocated into three groups randomly: XPS, TRN system, and HCM file system. Pre- and postinstrumentation scans were taken using a cone-beam computed tomography scanner to determine the amount of root dentin removed, mesiodistal and buccolingual transportation, and canal-centering ratio at 2, 5, and 8 mm from the root end. Statistical Analysis Used: Data were statistically analyzed using Kruskal-Wallis test and the significance level was set at P = 0.05. Results: TRN file system removed the least amount of root dentin. XPS showed statistically higher M-D canal transportation at 5 mm level from the apex. Conclusions: TRN file system showed better dentin preservation as compared to XPS and HCM. XPS showed the highest canal transportation at 5 mm. All three file systems performed similarly in terms of canal-centering ability.

20.
Aust Endod J ; 49 Suppl 1: 301-307, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36571470

RESUMO

To develop a model to test cyclic fatigue resistance of TruNatomy instruments undergoing rotational and axial movement at body temperature. A total of 288 Prime and Medium instruments were subjected to cyclic fatigue testing in simulated canals (at 37°C) using a model with either rotational movement only or rotational and axial movement simultaneously. Two different sized canals and three different types of curvatures were tested for each instrument (30/0.04 and 30/0.06 for Prime; 38/0.04 and 40/0.06 for Medium). The number of cycles to failure (fatigue resistance) was recorded. Rotational and axial movement of instruments led to greater fatigue resistance compared with rotational movement alone. Apical curvatures led to greater fatigue resistance than curvatures in the coronal and middle third. The developed dynamic model at body temperature to evaluate fatigue resistance of instrument closer simulates clinical scenarios.


Assuntos
Temperatura Corporal , Instrumentos Odontológicos , Falha de Equipamento , Preparo de Canal Radicular , Teste de Materiais , Titânio , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa