Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 23(9): e13707, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35719051

RESUMO

PURPOSE: This feasibility study evaluated the intra-fractional prostate motion using an ultrasound image-guided system during step and shoot intensity-modulated radiation therapy (SS-IMRT) and volumetric modulated arc therapy (VMAT). Moreover, the internal margins (IMs) using different margin formulas were calculated. METHODS: Fourteen consecutive patients with prostate cancer who underwent SS-IMRT (n = 5) or VMAT (n = 9) between March 2019 and April 2020 were considered. The intra-fractional prostate motion was observed in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The displacement of the prostate was defined as the displacement from the initial position at the scanning start time, which was evaluated using the mean ± standard deviation (SD). IMs were calculated using the van Herk and restricted maximum likelihood (REML) formulas for SS-IMRT and VMAT. RESULTS: For SS-IMRT, the maximum displacements of the prostate motion were 0.17 ± 0.18, 0.56 ± 0.86, and 0.18 ± 0.59 mm in the SI, AP, and LR directions, respectively. For VMAT, the maximum displacements of the prostate motion were 0.19 ± 0.64, 0.22 ± 0.35, and 0.14 ± 0.37 mm in the SI, AP, and LR directions, respectively. The IMs obtained for SS-IMRT and VMAT were within 2.3 mm and 1.2 mm using the van Herk formula and within 1.2 mm and 0.8 mm using the REML formula. CONCLUSIONS: This feasibility study confirmed that intra-fractional prostate motion was observed with SS-IMRT and VMAT using different margin formulas. The IMs should be determined according to each irradiation technique using the REML margin.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Margens de Excisão , Movimento (Física) , Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
2.
Med Dosim ; 48(3): 202-210, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37164788

RESUMO

The objective of this research is to investigate intrafraction motion correction on planning target volume (PTV) margin requirements and target and organ-at-risk (OAR) dosimetry in single-fraction lung stereotactic body radiation therapy (SBRT). Sixteen patients (15 with upper lobe lesions, 1 with a middle lobe lesion) were treated with single-fraction lung SBRT. Cone-beam computed tomography (CBCT) images were acquired before the treatment, between the arcs, and after the delivery of the treatment fraction. Shifts from the reference images were recorded in anterior-posterior (AP), superior-inferior (SI), and lateral (LAT) dimensions. The deviations from the reference image were calculated for 3 clinical scenarios: not applying intratreatment couch shifts and not correcting for pretreatment deviations < 3 mm ( scenario 1), not applying intratreatment couch shifts and correcting for pretreatment deviations < 3 mm ( scenario 2), and applying all pre- and intratreatment couch shifts (scenario 3). PTV margins were determined using the van Herk formalism for each scenario and maximum and average deviations were assessed. The clinical scenarios were modelled in the treatment planning system based on each patient dataset to assess target and OAR dosimetry. Calculated lower-bound PTV margins in the AP, SI, and LAT dimensions were [4.6, 3.5, 2.3] mm in scenario 1, [4.6, 2.4, 2.2] mm in scenario 2, and [1.7, 1.2, 1.0] mm in scenario 3. The margins are lower bounds because they do not include contributions from nonmotion related errors. Average and maximum intrafraction deviations were larger in the AP dimension compared to the SI and LAT dimensions for all scenarios. A unidimensional movement (several mm) in the negative AP dimension was observed in clinical scenarios 1 and 2 but not scenario 3. Average intrafraction deviation vectors were 1.2, 1.1, and 0.3 mm for scenarios 1, 2, and 3, respectively. Modelled clinical scenarios revealed that using scenario 3 yields significantly fewer treatment plan objective failures compared to scenarios 1 and 2 using a Wilcoxon signed-rank test. Intratreatment motion correction between each arc may enable reductions PTV margin requirements. It may also compensate for unidimensional negative AP movement, and improve target and OAR dosimetry.

3.
Radiother Oncol ; 158: 276-284, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33636230

RESUMO

BACKGROUND AND PURPOSE: To quantify intra-fraction tumor motion using imageguidance and implanted fiducial markers to determine if a 5 mm planning-target-volume (PTV) margin is sufficient for early stage breast cancer patients receiving neoadjuvant stereotactic ablative radiotherapy (SABR). MATERIALS AND METHODS: A HydroMark© (Mammotome) fiducial was implanted at the time of biopsy adjacent to the tumor. Sixty-one patients with 62 tumours were treated prone using a 5 mm PTV margin. Motion was quantified using two methods (separate patient groups): 1) difference in 3D fiducial position pre- and post-treatment cone-beam CTs (CBCTs) in 18 patients receiving 21 Gy/1fraction (fx); 2) acquiring 2D triggered-kVimages to quantify 3D intra-fraction motion using a 2D-to-3D estimation method for 44 tumours receiving 21 Gy/1fx (n = 22) or 30 Gy/3fx (n = 22). For 2), motion was quantified by calculating the magnitude of intra-fraction positional deviation from the pretreatment CBCT. PTV margins were derived using van Herkian analysis. RESULTS: The average ± standard deviation magnitude of motion across patients was 1.3 ± 1.15 mm Left/Right (L/R), 1.0 ± 0.9 mm Inferiorly/Superiorly (I/S), and 1.8 ± 1.5 mm Anteriorly/Posteriorly (A/P). 85/105 (81%) treatment fractions had dominant anterior motion. 6/62patients (9.7%) had mean intra-fraction motion during any fraction > 5 mm in any direction, with 4 in the anterior direction. Estimated PTV margins for single and three-fx patients in the L/R, I/S, and A/P directions were 6.0x4.1x5.9 mm and 4.5x2.9x4.3 mm, respectively. CONCLUSION: Our results suggest that a 5 mm PTV margin is sufficient for the I/S and A/P directions if a lateral kV image is acquired immediately before treatment. For the L/R direction, either further immobilization or a larger margin is required.


Assuntos
Neoplasias da Mama , Radiocirurgia , Radioterapia Guiada por Imagem , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Tomografia Computadorizada de Feixe Cônico , Marcadores Fiduciais , Humanos , Terapia Neoadjuvante , Planejamento da Radioterapia Assistida por Computador
4.
Radiat Oncol ; 15(1): 241, 2020 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-33069253

RESUMO

PURPOSE: Margins are employed in radiotherapy treatment planning to mitigate the dosimetric effects of geometric uncertainties for the clinical target volume (CTV). Here, we proposed a margin concept that takes into consideration the beam direction, thereby generating a beam-specific planning target volume (BSPTV) on a beam entrance view. The total merged BSPTV was considered a target for optimization. We investigated the impact of this novel approach for lung intensity-modulated radiotherapy (IMRT) treatment, and compared the treatment plans generated using BSPTV with general PTV. METHODS AND MATERIALS: We generated the BSPTV by expanding the CTV perpendicularly to the incident beam direction using the 2D version of van Herk's margin concept. The BSPTV and general PTV margin were analyzed using digital phantom simulation. Fifteen lung cancer patients were used in the planning study. First, all patient targets were performed with the CTV projection area analysis to select the suitable beam angles. Then, BSPTV was generated according to the selected beam angles. IMRT plans were optimized with the general PTV and BSPTV as the target volumes, respectively. The dosimetry metrics were calculated and evaluated between these two plans. The plan robustness of both plans for setup uncertainties was evaluated using worst-case analysis. RESULTS: Both general PTV and BSPTV plans satisfied the CTV coverage. In addition, the BSPTV plans improved the sparing of high doses to target-surrounding lung tissues compared to the general PTV plans. Both Dmean of Ring PTV and Ring BSPTV were significantly lower in BSPTV plans (38.89 Gy and 39.43 Gy) compared to the general PTV plans (40.27 Gy and 40.68 Gy). The V20, V5, and mean lung dose of the affected lung were significant lower in BSPTV plans (16.20%, 28.75% and 8.93 Gy) compared to general PTV plans (16.69%, 29.22% and 9.18 Gy). In uncertainty scenarios, about 80% of target coverage was achieved for both general PTV and BSPTV plans. CONCLUSIONS: The results suggested that plan robustness can be guaranteed in both the BSPTV and general PTV plans. However, the BSPTV plan spared normal tissues, such as the lungs, significantly better compared to the general PTV plans.


Assuntos
Neoplasias Pulmonares/radioterapia , Tratamentos com Preservação do Órgão/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Simulação por Computador , Humanos , Pulmão/patologia , Pulmão/efeitos da radiação , Neoplasias Pulmonares/patologia , Órgãos em Risco/patologia , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Incerteza
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa